Loading...
RF-10-1266r I Scheduled Inspection Date: July 20, 2010 Inspector: Bruhn, Norman Owner: PAULSON, ROBERT Job Address: 10205 NE 4 Avenue Project: <NONE> Miami Shores, FL Building Department Comments July 19, 2010 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 148334 Permit Number: RF -7 -10 -1266 Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC For Inspections please call: (305)762 -4949 Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number (305)751 -8593 Parcel Number 1132060170770 Phone: 305 - 757 -2612 REPAIR LEAK IN ROOF TILE WITH SPANISH S COLOR THRU TILE Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments e6- Page 10 of 25 Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Building Department Copy Owner Information Project Address 10205 NE 4 Avenue Miami Shores, FL 1132060170770 Block: Lot: ROBERT PAULSON Fees Due CCF Education Surcharge Permit Fee - Repairs Scanning Fee Technology Fee Total: Amount $0.60 $0.20 $100.00 $9.00 $0.80 $110.60 Address Contractor(s) Phone OBENOUR ROOFING SHEET METAL l 305 - 757 - 2612 Cell Phone Phone ROBERT PAULSON 10205 NE 4 AVE MIAMI FL 33138 -2416 (305)751 -8593 i Type of Work: Re Roof Additional Info: COLOR THRU Classification: Residential Scanning: 3 Authorized Signature: Owner / Applicant / Contractor / Agent Pay Date Pay Type Invoice # RF -7 -10 -38413 07/15/2010 Check #: 3621 07/13/2010 Check #: 5676 Amt Paid Amt Due $ 60.60 $ 50.00 $ 50.00 $ 0.00 Cell Available Inspections: Roof Review Inspection Type: Roof Repair Final Roof In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. July 15, 2010 Date July 15, 2010 1 BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Plumbing Mechani Owner's Name (Fee Simple Titleholder) gD)(f (SOD Phone # - Owner's Address 1 DPE of LI '- OiLikL ,lt City AttAlla f j State j Tenant/Lessee Name Job Address (where the work is being done) City Miami Shores Village FOLIO / PARCEL # Is Building Historically Designated YES Architect/Engineer's Name (if applicable) Value of Work For this Permit $ Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 q Electrical )O D S Pe IttkaLle County Miami -Dade Zip NO Zip 3) /J Phone # Phone # Square / Linear Footage Of Work: JUL ECIERVISD t 3 7 Y: ..... Permit No. 1 Q N Master Permit No. I vels (6-'15g -59Vj 3QS 1S) a(01,2- 3i/ ?, Contractor's Company Name t f # � , / Phone # Contractor's ddress / IJG t C' ? i1)/ City I Ur State FL Zip Qualifier Name air C f f). Day( uv Phone # State Certificate or Registration No. 0 g ( 0l 4-30I Certificate of Competency No. Type of Work: DAddition ['Alteration ONew / Er [' Demolition Describe W r a k . �S � (0k (Q**** * * * * * * * * * * * * * * * * * * * * * * * * * * * * **F ************* * ** * * * * * * * * * * * * * * * * * * * * * * * * * * ** Submittal FeeT , . QJ Permit Fee $ / " CCF $ CAQ0 CO /CC Notary $ Training/Education Fee $ 0490 Technology Fee $ ®' C Scanning 4. Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ (00 -( See Reverse side - -) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that.no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature 12. t° �� Signa7rf Owner or Agent Contractor The foregoing instrument was acknowledged before me this 9 The f egoing instrument was acknowledged before me this 7 day of o.4 20 /,b , by — Paul r O i' , day of who is personall known to me or who has produced who is personally `laiown to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: z . - 0 :I .43 ;7:; 0 i EC Ceal ' ° D art My Commission Expire 67 Pte. Az ! (Revised 02/08/06) NOTARY PUBLIC: Sign: Print: My Commission Expires: 20 as identification and who did take an oath. �i r; OTAR' CC-STATE uF '. 4 A Brands D. H a d �= On DD867S9g . 7 APPLICATION APPROVED BY ' 77' Q Plans Examiner Engineer Zoning Owner's Notification Form 07 MIAMFD COUNTY "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofmg system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofmg, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofmg contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofmg nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofmg system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to ' R t ov g . uppers in accordance with the requirements of: Chapter 15 and 1.6 herein and the Florida Bua . i ad ; l ing. I / � • • • i / 7. Ventilation: Most roof structures s'�io�lt l}a�esame ability t interior of the structural assembly (the building itself). The existing a reduced. Exception: Attic spaces, designed by a.lArida-licensed.eng the attic venting, venting shall not be rggqirexi. • • .. • • • • • Owner's/Agent's Signature: • Contractor's Signature: Property Address: ... . • • Permit Number: JUL 1 ow through the shall not be itect to eliminate PP S no, es age APP ZONING R P1.DG DEPT CF 'dAIT1 - 1 ALL FEDERAL •• • • • • • ••• •• • • • • • • • • • •• • • • ••• ••• •• • • •• ••• ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • •• • • • ••• • • • • • • • • • •• • • • • • • • • • ••• • • • • • • •• • • • • • • • • • • • •• •• • • • • • ••• HIGH VELOCITY HURRICANE ZONES UN 14 (FORM PERMIT APPLICATION Florida Building Code Edition 2004 High Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAG CO PL ETE THE NECESSARY SECTIONS O UNIFORM ROOFING F APPLICATION FORM AND ATTACH PERMIT THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of the Permit Application Form ATTACHMENTS REQUIRED: Fire Directory Listing Page From Notice Of Acceptance: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings Design Calculatia9S 15L+ ggphoc� R44Q3, or If Applicable, RAS RAS 128 127 or • Other Component Notice of Acceptances Municipal Permit pnljcatiop ••• Owners Notificaivn r • • • ing•Calau ation Do Documentation tats Roofing Only) Any Required Rde, Test cumentation • • .. • .. .. • . • E -Codes lamlets. Florida Building Code Edition 2004 High- velocity Hurricane Zone uniform Permit Application Form. Section A (General Information) Master Permit No. . I Process No. Contractor's Name Job Address /0 20-.4 /1/ ROOF CATEGORY O Low Slope 0 Mechanically Fastened Tile 0 Mortar/Adhesive Set Tile O Asphaltic 0 Metal Panel/Shingles 0 Wood Shingles/Shakes Shingles 0 Prescriptive BUR - RAS 150 ROOF TYPE 0 New Roof Cl Reroofing 0 Recovering Repair Q Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep SI • . . Roof Area (SF) 12 S / Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of • • • •• • • • • • • • •• • ••• • . • • • • • .• • • • • . /! • • • • • • • • • • • • • •• • • • • • • •• •• • • •• •• ••• • • • ••• • • Total (SF) A92 / • • • • ••• • • • • • • • •• •. • • • • • • •. •• • • • • !•• • • • • ..• • • • •• • . 4' •. • - • • �• .. • • • •••11 ASSEMBLIES AND ROOFTOP STRUCTURES Root System Man� use/ Notice of Accepterice.Nslmbe Florida Building Code Edition 2004 Mis►rVetocitY Murrlcana Zone Uniform Permit Application Form. siation o .wt _ Slope R oof Gy tet) Deck Typ • .. . ••• .•• • • • • • • • • • • • • • • • . • • • .. . • •• . S • •• ••• • rd Minimum Design Wind Pressures, if Applicable (From RAS S 327 or Calculations): <� r3: S P 1: P2: Maximum Desi • n Pressure (From the Pp_ • c A • prove! Specific System): 5120-SYSem.Q §$QfIP 1 fxrir Boor 5Yrrei' e underlavment• Insulation: Fire Barrier: Fastener Type & Spacing: Adhesive Type: ) L Type Cap Sheet: fit pd Roof Covering: /14 Mean Roof Height: • F • .. • • • • • • hype S Size Drip • Edge: . •• •,,, .. . • • .. • • • . . • . •. • . . • • .. • • • • • .•. • • • • • • • • • • • • • • •• • • • •• .. • • ••• 9 • I Pem. Se-41/6 FLORIDA BUILDING CODE— BUILDING Florida Building Code Edition 2004 High- Velocity Hurricane Zone Uniform Permit Application Form. • Section E (Tile Calculations) For Moment has tUe systems, choose either Method 1 or 2. Compare the values for M with the values from M If the Mt values are greater than or equal to the M values. for each area of the roof, then the tile attachment method is acceptable. (P x L (P x L an name sat m nada MBE .- BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Method I " omen Based Tille Per RAS 127" (P s ®. . Mg: 7./ a M Product Approval Mf Me1 (P2: x ?` 2211 y+ g c ar - a Mr2/22'f7 Product Approval Mt _E (P r /a •233 G " ) - Mg: t!' f- • Mr? Product Approval M �G g r7 • •••• ••••. • Method 2 'Simplified Tile Calculations Per Table Below" Requited Moment of Resistance (Mr) From lhble Below Product Approval M f M, required Moment Resistance Moan Root Height -► Roof Slope j 2:12 • 3:12 4:12 5:12 6:12 7:12 15' 34.4 32.2 30.4 25.4 25.4 24.4 20' 386 34.4 32.2 30.1 28.0 25.9 25' 38.2 36.0 33.8 316 29.4 27.1 30' 39.7 37.4 35.1 32.8 30.5 28.2 40' 42.2 39.8 37.3 34.9 32.4 30.0 *Must be used In conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For ()putt based the systems use Method 3. Compared the values fore with the values for Fr If the F' values are greater than or equal to the Fr values. for each area of the roof, then the tile attachment method Is acceptable. Method 3 "Moment Based The Calculations Per RAS 127" x w::s _ � - W: x cos 0 = F Product Approval F' a - X w: m •_� - W: x c B , +a F Product Approval F m F Product Approval Ir (P3: xL s+ - Xw:n 1 W: x cos re to information Site Site Approval Approval Approval • • •• alarid + • . ••• • • • • • iucr 11 A141044 . laced • • • • • sal • • • • • ••• • duet Approval ••• • alas thedime oCitenalt application. • • • i • • • • • • •• •• ••• • • Where to find 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 15.35 Wh Symbol Description RA, 1 P3 Design Pressure PI or or lob H Mean Roof Height lob a Roof Slope Pro a Aerodynamic Multiplier Pro Restoring Moment due to Gravity . Attachment Resistance • • . jh'11 • _ Pre itel • Required Moment Resistancz • j • • * Minimum Attschmen` • • • • • • • • • • F' • I Pn Resistance ea • • Pa Required Uplift Resist • ; • Pr • • • • • • • Ile W SS • • W • • Average • 'I1e Dimensions • • • �--- • L a length I Pis W = width bTdinit2: cl All calculations must be submitted to3he . • • • as Florida Building Code Edition 2004 High- Velocity Hurricane Zone Uniform Permit Application Form. • Section E (Tile Calculations) For Moment has tUe systems, choose either Method 1 or 2. Compare the values for M with the values from M If the Mt values are greater than or equal to the M values. for each area of the roof, then the tile attachment method is acceptable. (P x L (P x L an name sat m nada MBE .- BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Method I " omen Based Tille Per RAS 127" (P s ®. . Mg: 7./ a M Product Approval Mf Me1 (P2: x ?` 2211 y+ g c ar - a Mr2/22'f7 Product Approval Mt _E (P r /a •233 G " ) - Mg: t!' f- • Mr? Product Approval M �G g r7 • •••• ••••. • Method 2 'Simplified Tile Calculations Per Table Below" Requited Moment of Resistance (Mr) From lhble Below Product Approval M f M, required Moment Resistance Moan Root Height -► Roof Slope j 2:12 • 3:12 4:12 5:12 6:12 7:12 15' 34.4 32.2 30.4 25.4 25.4 24.4 20' 386 34.4 32.2 30.1 28.0 25.9 25' 38.2 36.0 33.8 316 29.4 27.1 30' 39.7 37.4 35.1 32.8 30.5 28.2 40' 42.2 39.8 37.3 34.9 32.4 30.0 *Must be used In conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For ()putt based the systems use Method 3. Compared the values fore with the values for Fr If the F' values are greater than or equal to the Fr values. for each area of the roof, then the tile attachment method Is acceptable. Method 3 "Moment Based The Calculations Per RAS 127" x w::s _ � - W: x cos 0 = F Product Approval F' a - X w: m •_� - W: x c B , +a F Product Approval F m F Product Approval Ir (P3: xL s+ - Xw:n 1 W: x cos re to information Site Site Approval Approval Approval • • •• alarid + • . ••• • • • • • iucr 11 A141044 . laced • • • • • sal • • • • • ••• • duet Approval ••• • alas thedime oCitenalt application. • • • i • • • • • • •• •• ••• • • Where to find 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 15.35 BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVLSION NOTICE OF ACCEPTANCE (NOA) Monier Lifetile, LLC 200 Story Road Lake Wales, FL 33898 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Spanish `S' Nuevo Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, followed the e n it s hall by be done in its entirety. p n it shall INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through G. •. • • • • • . • The submitted documentation was ; eviewed liy i1lex:fieia.: • •• • • • • •• - • • • • • • �t • •• ••• •• • ••• • • • • • • • • • • • •• • • ••• ••• • • • • • • • • • • • • • • • • • • • • • •• • • • • • ••• • ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• 000 • • • 000 • • MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOA No.: 09- 0331.10 Expiration Date: 05/20/14 Approval Date: 05/20/09 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Sub- Category: Material: 2. PRODUCT DESCRIPTION Manufactured by Applicant Monier Lifetile Spanish 'S' Tile Trim Pieces 2.1 SUBMITTED EVIDENCE: Test AEencv Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Roofing High Profile Roofing Tiles Concrete 1. SCOPE This approves a system using Monier Lifetile Spanish `S' Nuevo Concrete Roof Tile, as manufactured by Monier Lifetile LLC in Lake Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. Dimensions 1 =17" w= 9 -3/4" min. .63" thick 1= varies w = varies varying thickness Test Identifier • • • • • • • • • 44-b83 • • • • ••• •• • • ••• • • • • • • • • • •• • • • • • • • • • • • • • •• • • • ••• • • • • • • • • • • • • • •• •• ••• • • Test Specifications 7161 -03 Appendix III 7161 -03 Appendix II P0647 -01 PO402 94 -084 25- 7183 -4 TAS 112 High profile, interlocking, one - piece, 'S' shaped, high- pressure extruded concrete roof tile equipped with three nail holes. For direct deck nail -on, mortar set or adhesive set applications. TAS 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report Date Static Uplift Testing Dec. 1991 PA 102 & PA 102(A) Wind Tunnel Testing Dec. 1991 PA 108 (Nail -On) Wind Tunnel Testing Aug. 1994 PA 108 (Mortar Set) Withdrawal Resistance Testing Sept. 1993 of screw vs. smooth shank nails Static Uplift Testing May 1994 • PA 101 (Mortar Set) • • • • Static Uplift Testing April 1994 •.. • • PA 101 (Adhesive Set) Static Uplift Testing Feb. 1995 PA 102 (2 Quik -Drive Screws, • Direct Deck) •• • • •• • • • • • • NOA No.: 09- 0331.10 • • • • Expiration Date: 05/20/14 Approval Date: 05/20/09 • • • • • • Page 2 of 6 •.. . • • • • . . • . • • • •• •• • •.. • • ••• Product Description Test Agency The Center for Applied Engineering, Inc. Redland Technologies The Center for Applied Engineering, Inc. Nutting Engineering Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. 3. LIMITATIONS Test Identifier 25- 7214 -3 Letter Dated Aug. 1, 1994 Project No. 307025 Test #MDC -78 13343.1 520111 -3 520191 -2 -1 Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Walker Engineering, Inc. Calculations • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •. .. .• • . • • or • ••• • • • • • • • ••• • • • • • • • • • • • • • • • ... • • • • • •. • • • • •• .. • .• • • • • .. • • Test Name/Report Static Uplift Testing PA 102 (1 Quik -Drive Screw, Direct Deck) Wind Tunnel Testing PA 108 (Nail -On) Wind Driven Rain PA 100 Physical Properties TAS 112 Static Uplift Testing PA 101 Aerodynamic Multiplier 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 25 -7183 Restoring Moment Due to Gravity Two Patty Adhesive Set System Date March, 1995 Aug. 1994 Oct. 1994 Feb 2009 Dec. 1998 March 1999 Jan 2009 February 1996 April 1996 December 1996 March 1995 Jan 2009 April 1999 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofmg Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Monier Lifetile Spaaisfi V:141eito Conorefe Aoof Tile and its components shall be installed in strict compliance ;Pith Rqf n Apppicpti )f St RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment CalCdlatiotii • • • • • NOA No.: 09- 0331.10 Expiration Date: 05/20/14 Approval Date: 05/20/09 Page 3 of 6 Table 4: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf) for Nall -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Monier Lifetile Spanish 'S' Nuevo Tile 2 -10d Ring Shank Nails 28.6 41.2 1 -10d Smooth or Screw Shank Nail 5.1 6.8 2 -10d Smooth or Screw Shank Nails 6.9 9.2 1 .#8 Screw 20.7 20.7 2 .#8 Screws 43.2 43.2 1 -10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 1 -10d Smooth or Screw Shank Nail (Eave Clip) 29.3 29.3 2 -10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 2 -10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 Table 1: Average Weight (W) and Dimensions (I x w ) Table 3: Restoring 3 ":12" Moments due 4 ":12" to Gravity - M 5 ":12" (ft-lbf) 6 ":12" 7 ":12" or greater Tile Profile 2 ":12" Monier Lifetile Spanish 'S' Nuevo Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck N/A 6.00 N/A 5.93 N/A 5.83 N/A 5.70 N/A 5.56 N/A 5.39 Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (lbf) Length -I (ft) Width -w (ft) Monier Lifetile Spanish 'S' Nuevo Tile 8.95 1.417 0.8125 Table 2: Aerodynamic Multipliers - x Lft') Tile Profile A. MI Direct Deck Application Monier Lifetile Spanish 'S' Nuevo Tile 0.233 • • • • • • • • • . •• •• • • • .. • • • .. • •• • • • • • • • • • • • • • • • • • • • • • • • • • • .• • • •• • • •• • • • • • • • • • • • S. ••• • • • • • S • • • • • • • • • • • • • •• • • • • • • • • • • • •• • • • • • • • • • ••• • • • • • • • . • NOA No.: 09- 0331.10 Expiration Date: 05/20/14 Approval Date: 05/20/09 Page 4 of 6 Table 6: Attachment Resistance Expressed as a Moment M (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Monier Lifetile Spanish 'S' Nuevo Tile 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 10.7 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Tile Application Adhesive Minimum Attachment Resistance 29.3` Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Application Tile Profile Monier Lifetile Spanish 'S' Nuevo Tile 3 Large paddy placement of 63grams of PolyPre'''. 4 Medium paddy placement of 24grams of PolyProT"" Polyfoam PolyPro Polyfoam PolyPro Minimum Attachment Resistance 66.5' 38.7" Table 8: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Mortar Set Systems Tile Profile Monier Lifetile Spanish 'S' Nuevo Tile Tile Application Mortar Set Attachment Resistance 24.5 5. LABELING All tiles shall bear the imprint or identifiable marking of' the manufacturer's name or logo as seen below, or following statement: "Miami -Dade County Product Control Approved ". MONIERLIFETILE LLC, SPANISH 'S' NUEVO TILE (LAKE WALES, FL PLANT) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application fgr•builalirg permit h011.ie a ompanied by copies of the following: 6.1.1 This riptice,pf rivoeplaica : • 6.1.2 Any other dc4 Dt zeluile l by the Building Official or applicable building code in order to properly evaluate the installation of this system. • ••• •• • • • • • • • • • • • • • • • • • • • • • • to • 05 • • • •• • • • • • ••• • .. • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • •• • •• • • • ••• • • • • ••• • • • • • • •• • • • • •• • • • • • NOA No.: 09- 0331.10 Expiration Date: 05/20/14 Approval. Date: 05/20/09 Page 5 of 6 PROFILE DRAWINGS 17" 9 -3/4" MONIER LIFETILE SPANISH 'S' NUEVO CONCRETE ROOF TILE END OF THIS ACCEPTANCE .. ... • • • • • • • . • • • • • • • • •••• • • •• •. • • • • ... ••• • • • • • • • • . • • • • • • • .. • • • ••• • . • • • • • • • • • • • • • ••• • • • • • • • .. • . .. ••• • • • • • • • • • • • • .. • NOA No.: 09- 0331.10 Expiration Date: 05/20/14 Approval Date: 05/20/09 Page 6 of 6 MIA DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® AH160 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if thgre_bas been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.01- 0521.02 and consists of pages 1 through 7 The submitted documentation was reviewed by J; rge L. Acebo. • • • • •• ••• • •• • • • •• • ••• • ••. • • • • • • • • • • ' • • • • • • • • • • • • • • • • • • • •• • • • • •• • • • • • ••• • • • • • • • • • ••• • • • • • • ••. • • • • • • • • • • • . • • •. S 00 ' •• • • • • •• . MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 1 of 7 ROOFING ASSEMBLY APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications Polypro 'I AH160 N/A TAS 101 Foampro® RTF1000 ProPack® 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content ASTM D 2856 N/A N/A Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. • •• ••• • • • • • •• • • • • • •• ••• • • • • • • • • • Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 • • •• • • • •• • ••• ••• • • • • • • • • • • • • • • • • • • • • • • •• • • • • • ••• • ••• • • • • ••• • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• • • • • • •• •• ••• • • • • •• • • Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment Results 1.6 lbs./ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -] PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 Miles Laboratories 25-7492 SSTD 11 -93 12/12/95 Pol NB- 589 -631 ASTM D 1623 02/01/94 ymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[l J ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 • 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH 160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. 1 F • ••4,• • • i2 • • •• •• •• • • • ••• *s •'• ••• •••• ••• • • NOA No.: 06-0201.02 • • • • • • • • • Expiration Date: 05 /10 /11 • • • • Approval Date: 04/13/06 • • ••• • Page3of7 ••• • • • • ••• • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Flat, Low, High Profiles High Profile (2 Piece Barrel) Flat, Low, High Profiles Flat, Low, High Profiles Placement Detail #1 #1 #2 #3 Single Paddy Weight Min. (grams) 35 17 /side on cap and 34 /pan 24 Two Paddy Weight per paddy Min. (grams) N/A N/A N/A 8 LABELING: All Polypro® AH 160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Offiiialiti applicable building code in order to properly evaluate the installation of this system. • • • • . • • • • •• • • • • ••• • ' •• '•• • • •• ••• •:• ••• ••• • • • • • .• • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • ••• ••• ••• • • • • ••• • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• •.• • • • ••• • • NOA No.: 06- 0201.02 Expiration Date: 05 /10/11 Approval Date: 04 /13/06 Page 4 of 7 ADHESIVE PLACEMENT DETAIL I SINGLE PATTY •• ••• • • • • • •• • • • • • • • • •• ••• •• • • • •• • ••• • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • •• • • • • • • • ••• • • • • • • • •• • • • • • • • • • •• • • • • • •• • • • • • • Eave course only: Keep adhesive approx. 41n, up from weepholte 1 )Piaco 8 =0 adheaNato achieve 17to23 bra stptae lathes In corded with tho pan the 2) Ttoa covets upside down. Place adhesive 1f2 ha` To14t Fromoutsideedgeoltovarttle �t Then Meld t le. %') • . • • • • • • • • •• •• NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 5 of 7 • ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY •• ••• • • • • • •• • • • • • • • •. ••• •• • • • •• • • • • • • • • • • • • • Expiration Date: 05/10/11 • • • • • • • • • • • • • • • • • • • • • • • • Approval Date: 04/13/06 • • •• • • •• • • • • • • • ••• • Page6of7 ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • NOA No.: 06-0201.02 Nail through plastic cement 3 in. x 3 hi. 4 in ' Single paddy on underlayment on top of We ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Eave Course •• •••• • • • • • • • • • ••• • • • • • • • • • • END 0F; III KC:C'EyTANCE •• ••• •• • • • •• • ••• ••• ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • •• • • • • • • • ••• • ••• • • . • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• Y• ••• • • • ••• • • Nail through plastic cement Underlayment / }}j3in.x3in. Single 4In. paddy on under - layment Single paddy under We Single paddy between tile 2 In. x T in. medium size paddy eave course only Single paddy on top of tile Ewe Course Weephole Eave closure Drip edge Single paddy between tile 2 In. x 71n. medium Fascia paddy eave course only Ewe Closure NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 7 of 7