Loading...
RCRT-08-1313UNITED STATES POSTAL. SERVICE 2. Article Number (iiansfer from service label) • Sender. Please print your name, address, and ZIP +4 in this box • MIAMI SHORES VILLAGE 10050 N. E. 2nd AVENUE MIAMI SHORES, FL 33138 rcl--i , (3 1 rrII, 111111111„1jd,11, rl1I„II I „I11,lill,l,nId„I,1,,1 SENDER: COMPLETE THIS SECTION COMPLETE THIS SECTION ON DELIVERY B. Received by (Printed Name) • Complete Items 1, 2, and 3. Also complete item 4 if Restricted Delivery is desired. • Print your name and address on the reverse so that we can return the card to you. • Attach this card to the back of the mailpiece, or on the front if space permits. Li-r) tAinffrtowe '123 nib- 2A mykti svioyes D. Is delivery address different from item 1? ❑ Yes If YES, enter delivery address below: ❑ No 3. Service iSfpe ❑ Certified Mall ❑ Rimed ❑ Insured Mall 4. Restricted Delivery? (Extra Fee) 7007 2680 0001 3276 2889 PS Form 3811, February 2004 Domestic Retum Receipt First -Class Mail Postage & Fees Paid USPS Permit No. G -10 0 Express 'Mall ❑ Retum Receipt for Merchandise ❑ C.O.D. ❑ Yes 102595.02 -M -1640 D ^ cp ru -n N ru m r1 O O co -o ru P- P- U.S. N US. Postal Service. CERTIFIED MAILRECEIPT (Domestic Mail Only; No Insurance Coverage Provided) For delivery information visit our website at www.usps.coma Postage Certified Fee Retum Receipt Fee (Endorsement Required) Restricted Delivery Fee (Endorsement Required) Postmark Here i . ►) I.- ii!..■ Send To G�'� Wait Ap£ 13c . .L or PO Box No. City, State. ZIP+4 PS Form 3800. August 2006 See Reverse for InslruclIOns Certified Mail Provides: ® A mailing receipt o A unique Identifier for your maliplece ® A record of delivery kept by the Postal Service for two years Important Reminders: E Certified Mall may ONLY be combined with First -Class Malls or Priority Made. a Certified Mail is not available for any class of international mail. E3 NO INSURANCE COVERAGE IS PROVIDED with Certified Mail. For valuables, please consider Insured or Registered Mail. 0 For an additional fee, a Return Receipt may be requested to provide proof of delivery. To obtain Retum Receipt service, please complete and attach a Retum Receipt (PS Form 3811) to the article and add applicable postage to cover the fee. Endorse mailpiece Return Receipt Requested °. To receive a fee waiver for a duplicate retum receipt, a LISPS® postmark on your Certified Mall receipt is required. E For an additional fee, delivery may be restricted to the addressee or addressee's authorized agent. Advise the clerk or mark the mallpiece with the endorsement °Restricted Delivery°. n If a postmark on the Certified Mali receipt is desired, please present the arti- cle at the post office for postmarking. If a postmark on the Certified Mall receipt is not needed, detach and affix label with postage and mail. IMPORTANT: Save this receipt and present it when making an Inquiry. PS Form 3800, August 2008 (Reverse) PSN 7530-02-000-9047 BUILDING PERMIT APPLICATION FBC 2004 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. A O 1 30 Master Permit No. Permit Type (circle): Building P / � ' � Roofmg � Ave) Owner's Name (Fee Simple Titleholder) 1 ar) "-' c1 Ave Phone # Owner's Address City State Zip Tenant/Lessee Name Phone # Job Address (where the work is being done) 9i1,3 City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # Is Building Historically Designated YES NO Contractor's Company Name Phone # Contractor's Address City State Zip Qualifier Name Phone # State Certificate or Registration No. Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ Square / Linear Footage Of Work: Type of Work: ['Addition ['Alteration [Kew ❑ Repair/Replace ❑ Demolition Describe Work: * * * * * **** ** * *4; ** x********* *:x*** * * * ** ** F ees * * ** * *** ******:x+x********* ** * *** * *****,x***** Submittal Fee $ Permit Fee 6 a) CCF $ CO /CC Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side -* Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOII.RRS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of , 20 _, by , day of , 20 _, by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: My Commission Expires: My Commission Expires: * *, x**** * * **************** * * * * ** x******* ** * * * * * * * *x * * *** ** * * * * * *** * * * * * * ** * *** ** * *** * ** : * ** *** * * ********* * ** APPLICATION APPROVED BY: (Revised 07/10/07) f - !'vc) Plans Examiner Engineer Zoning 7/21/2008 MIAMI SHORES VILLAGE Building Department Certified Mail # 7007 2680 0001 3276 2889 10050 NE 2 Ave, Miami Shores Fl, 33138 Tel: 305 - 795 -2204• Fax: 305- 756 -8972 Property located at: Address: 9723 NE 2 Avenue Miami Shores, Florida, 33138- Permit Number: RCRT - 7 - 08 - 1313 Folio # 11 3206 - 013 4210 Notice of Required Inspection/Certification Dear Owner: The Village has been notified by Metro -Dade Building & Zoning Department that the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8 -11, the subject property must be inspected by a Florida Registered Architect or Engineer and a report furnished to this office. A report and a fee of two - hundred fifty dollars must be submitted to this office within ninety (90) days of receiving this Notice of Required Inspection /Certification. If you would like a copy of Minimum Inspection Procedural Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305- 795 -2204. • PRVMUZIM 4 m0 BY: ? Rcaz � -i3 i3 BUILDING RECERTIFICATION INSPECTION REPORT G N PREPARED FOR: 7800 NE 2 AVE LTD. PROPERTY LOCATED AT: 9723 NE 2 AVE MIAMI, FLORICpA P O , DEPT P PREPARED BY:: r:r O COMPLIANCE WITH ALL FEDERAL engineering group, inc. 10400 NW 33r Street, Suite 220, Doral, Florida 33172 TELEPHONE: (305) 592 -4538 / FAX: (305) 592 -1433 • 1 ('``LINTY RULES AND REGULATIONS • • • October 21, 2010 7800 NE 2 Ave Ltd. 419 W 49 Street #105 Hialeah, FL 33012 engineering group, inc. RE: 40 -Year Recertification of Building Located at 9723 NE 2 Avenue Dear Building Official: In accordance with Section 8 -11(f) of the Code of Miami -Dade County, GNP Engineering Group, Inc. has performed an inspection of the building located at 9723 NE 2 Avenue and determined the building to be structurally and electrically safe for continued use under present occupancy. The findings of our inspection are summarized in this written report that follows the Minimum Inspection Procedural Guidelines for Building Recertification and is accompanied by a set of photos depicting the condition of the building. This report does not preclude the building from subsequent inspections as deemed necessary by the Building Official. As a routine matter, in order to avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure. To the best of our knowledge and ability, this report represents an accurate appraisal of the present condition of the building based upon careful evaluation of observed conditions, to the extent possible. Should you have any questions concerning this report, please feel free to contact us at (305) 592 -4538. I 1111111 Sincerely, . GO z GNP Engineering Gro cc: File .•�GE , � • s s No. 507 Benny P. ez, P.g STATE OF President ,, O,c > ,/L O R ° ' c; c�' FL. Uc. No. 50746 ♦/ ' ° e o o '/ ♦eS5'fONA � , 808819` Attachments: Structural Report Electrical Report Photos 10400 N.W. 33rd Street, Suite 220 Doral, Florida 33172 1111 Tel.: 305 -592 -4538 ® Fax: 305 -592 -1433 No, 4 Angel Paredes,! —. STAT Vice- Presidenfr O ,c. FL. Uc. No. 44096 ��S • O R ®/1 / ONA Civil Engineering • Structural Engineering ® Construction Management ® Infrastructure Assessment • Database Management l it i 096 • Data Cal ien • 40-Year Recertification • Due Diligence • • • En in rin IN PE TI PART A - STRUCTURAL 1. DESCRIPTION OF STRUCTURE a. Name of Title: 7800 NE 2nd Ave Ltd. b. Street Address: 9723 NE 2 Ave., Miami Shores, Florida c. Legal Description: MIAMI SHORES SEC 1 AMD PB 10 -70 LOTS 10 & 11 BLK 31 LOT SIZE 95.000 X 130 OR 17437 -1378 1196 4 (2) OR 17437 -1378 1196 01 d. Owner's Name: 7800 NE 2nd Ave Ltd. e. Owner's Mailing Address: 419 W. 49 St. #105, Hialeah, FL 33012 f . Building Official Folio Number: 11- 3208 - 013 -4210 g. Year Built: 1948 h. Building Code Occupancy Classification: Group M Occupancy i. Present Use: Mercantile j. General Description: One -story building, CBS construction, 9,459 SF. k. Nature of Present Loading: Nine (9) businesses identified as nos. 210, 212, 214, 216, 9723, 9725, 9723, 9721 and 9717. 1. Additions to Original Structure: Unable to determine since plans were not available. 2. INSPECTIONS: a. Date of Notice of Required Inspection: N/A b. Date of Actual Inspection: October 13, 2010 c. f Name and Qualification of Individual SubmLU $ 1041 Report: Angel S. Paredes, P.E. (License #44096) ��?, ,\ E N S F • FS ' Page S -1 of 7 O -�; '��,c� • c � o R \c; P � �2ETnge1 S. Paredes • '` PE #44096 A • • • G P En i eerin r s , I_ PECT d. Description of Any Laboratory or Other Formal Testing: Not required; used manual and visual inspection procedures. e. Accessibility for Inspection: The building was accessible at time of inspection. 3. REPAIRS: a. Structural Repair: [ X ] None Required [N /A] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify structural deficiencies and to recommend that repairs be made to the structure, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the structural deficiencies as identified in this report. In addition, the Owner will be responsible for obtaining the necessary permits for construction and for having a licensed Contractor perform the work in accordance with the requirements of the Florida Building Code. 4. SUPPORTING DATA a. 7 Sheets of Written Data (Part A) b. 2 Photographs (Part A & Part B) Page S -2 of 7 . ' � _ S PAR - .0 , • • -o- TA L F �� ; �a ��� N .. " , e , ' !� #e 8 /ONot ,‘ Angel Paredes PE #44096 • • • En ine rin Gro 1 In P TI I REP 1 RT c. N/A Drawing (Plan) 5. PRESENT CONDITION OF STRUCTURE a. General Alignment: Fair condition. [N /A] Bulging - None observed during inspection. [N /A] Settlement - None observed during inspection. [N /A] Deflection - None observed during inspection. [N /A] Expansion - No expansion above normal observed during inspection. [N /A] Contraction - No contraction above normal observed during inspection. b. Portions Showing Distress: None observed. c. Surface Conditions: Fair condition. d. Cracks: Hairline and fine sized stucco cracks. e. General Extent of Deterioration: No significant deterioration of structure observed. f. Previous Patching or Repairs: None visible. 6. MASONRY BEARING WALLS a. Concrete Masonry Units: Fair condition. b. Reinforced Concrete Tie Columns: Fair condition. c. Reinforced Concrete Tie Beams: Fair condition. d. Lintels: Fair condition. e. Other Type Bond Beams: Fair condition. Page S -3 of 7 • .0 ifi .,�,�\ENS 1/49 096 'c S ' AT OF ;4 Ia s 09 jO� ^`f` k F�ri ,©t �t :% i' �4 �i,l l 11 111e_ t, ! i h �A N' s PE #44096 • • GNP E gineering Group, Inc INSPECTION RE f. Masonry Finishes (Exterior): 1) Stucco — Fair condition. 2) Veneer —N/A 3) Paint - Fair condition. 4) Other - N/A h. Masonry Finishes (Interior): 1) Vapor Barrier - N/A 2) Furring & Plaster — Fair condition. 3) Paneling — N/A 4) Paint - Fair condition. 5) Other - N/A L Cracks: 1) Location - No cracks observed in concrete masonry walls. 2) Description - N/A j. Spalling: 1) Location - No spalling observed in concrete masonry walls. 2) Description - N/A k. Rebar Corrosion: [ X ] None Visible [N /A] Minor (patching will suffice) [N /A] Significant (but patching will suffice) Page S -4 of 7 �•� ,: ■f . 4096 -o ' E /j4 :4, cr. = °�, F`gR10 % 1 .` ' #44 71©NAB ttt Angel S r arec � es t t PE #44096 11P IN /A] Significant (structural repairs required) / Description • GNP Engineering Group, Inc. INSPECTION REPORT 7. FLOOR & ROOF SYSTEMS a. Roof System: 1) Description — Flat roof with modified roofing surface. The roof framing consists of wood joists. 2) Heavy Equipment and Condition of Supports — HVAC equipment supports observed to be in fair condition. 3) Types of Drains /Scuppers and Condition — Scuppers and downspouts observed to be in fair condition. 4) General Condition - The roof surfaces were observed to be in fair condition. b. Floor System: The floor system consists of concrete slab on grade. Floor coverings, furniture and stored materials prohibited a visual inspection of the entire floor surface. However, visible floor surface was observed to be in good condition. c. Concealed Spaces Opened for Inspection: Roof framing is concealed by ceiling finishes. 8. STEEL NI(AMING SYSTEMS (N /A) a. Description: N/A b. Exposed Steel: N/A c. Concrete or Other Fireproofing: N/A d. Elevator Sheave Beams & Connections, and Machine Floor Beams: N/A e. Concealed Spaces Opened for Inspection: N/A f. General Condition: N/A Page S -5 of 7 `�a. . GE ,,,.,RFp ?�\ GENSF•F • 096 . = *: 4 /i) ,:e 'P k981/61Qiiik %r0° An S. reties PE #44096 En.ii - • Inc 410 9. CONCRETE FRAMING SYSTEMS a. Description: CBS construction with reinforced concrete columns and concrete beams. b. Cracking/Spalling: [ X ] Not Significant [N /A] Location and Description of Members Affected and Type c. General Condition: Fair condition. d. Rebar Corrosion: [ X ] None Visible [N /A] Location and Description of Members Affected [N /A] Significant (but patching will suffice) [N /A] Significant (structural repairs required) • e. Samples Chipped Out in Small Areas: [X ] No [N /A] Yes / Description f. Concealed Spaces Opened for Inspection: N/A • 10. WINDOWS a. Type: Aluminum and wood frame, single hung and fixed type windows. b. Anchorage: Screws observed to be secure and in fair condition. c. Sealants: Fair condition. d. Interior Seals: Fair condition. Page S -6 of 7 TIS ' PIRT ,a ?i +iiialeff �•�GE' S PAq�`�. Q:• \ GE NS��Fcr • 4096 F '`�e� siNf' 1r�aa Angel S. Paredes PE #44096 • • • n 'n erin e. General Condition: Fair condition. 11. WOOD FRAMING a. Type: Wood joists for roof framing. b. Metal Fittings: Not visible. c. Joints: Not visible. d. Drainage: None visible. e. Ventilation: Vent screens along walls. TI f. Concealed Spaces Opened for Inspection: Wood joists are concealed by ceiling finishes. Page S -7 of 7 l lllait < � ,,, S ' • • �'�, e`Q�•• ENs Sk , • =*: L " 1 9 / /1� S`t � An gel S. Paredes PE #44096 • • GNP Engineering Group, Inc. INSPECTION REPORT PART B - ELECTRICAL 1. DESCRIPTION OF STRUCTURE a. Name of Title: 7800 NE 2 Ave Ltd. b. Street Address: 9723 NE 2 Ave., Miami Shores, Florida c. Legal Description: MIAMI SHORES SEC 1 AMD PB 10 -70 LOTS 10 & 11 BLK 31 LOT SIZE 95.000 X 130 OR 17437 -1378 1196 4 (2) OR 17437 -1378 1196 01 d. Owner's Name: 7800 NE 2 Ave Ltd. e. Owner's Mailing Address: 419 W. 49 St. #105, Hialeah, FL 33012 f. Building Official Folio Number: 11- 3208 - 013 -4210 g. Year Built: 1948 h. Building Code Occupancy Classification: Group M Occupancy i. Present Use: Mercantile j. General Description: One -story building, CBS construction, 9,459 SF. k. Nature of Present Loading: Nine (9) businesses identified as nos. 210, 212, 214, 216, 9723, 9725, 9723, 9721 and 9717. 1. Additions to Original Structure: Unable to determine since plans were not available. 2. INSPECTIONS: a. Date of Notice of Required Inspection: N/A b. Date of Actual Inspection: October 13, 2010 Page E -1 of 7 0111 I F •• ca r ; . ; *: AT C OF ��; 'F ' ' ' y s $ONAL 04,0' Benny P. Waal z PE #50746 c. Name and Qualification of Individual Submitting Inspection Report: • Benny P. Gonzalez, P.E. (License #50746) • GNP Engineering Group, Inc. INSPECTION REPORT d. Description of Any Laboratory or Other Formal Testing: Not required; used manual and visual inspection procedures. e. Accessibility for Inspection: The building was accessible at time of inspection. 3. REPAIRS: a. Electrical Repair: [ X ] None Required [N /A] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify electrical deficiencies in the buildings and to recommend that repairs be made to the electrical system, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the electrical deficiencies as identified in this report. In addition, the Owner will be responsible for obtaining the necessary permits for construction and for having a licensed Contractor perform the work in accordance with the requirements of the Florida Building Code. 8 44 . ` i S ATEb • ,�. .Benny P. Gonzalez % • 4 01310' �G � Page E -2 of 7 ;` PE #50746 � ''•S � ©NAL E •`� En in erin PE IO P 4. SUPPORTING DATA a. 7 Sheets of Written Data (Part B) b. 2 Photographs (Part A & Part B) c. N/A Drawing (Plan) • • 5. ELECTRIC SERVICE a. Estimated Size, Amperage: 600 amps [ X ] Fuses [ ] Breakers b. Phase: [ X ] Three Phase [ ] Single Phase c. Condition: [ ] Good [ X ] Fair [ ] Needs Repair d. Comments: No comments. 6. METER AND ELECTRIC ROOMS a. Clearances: [ X ] Good b. Comments: No comments. 8. ELECTRICAL PANELS a. Location: Nine (9) locations identified as nos. 210, 212, 214, 216, 9723, 9725, 9723, � 7. GUTTERS a. Location: [ X ] Good [ ] Requires Repair b. Taps & Fill: [ X ] Good [ ] Requires Repair c. Comments: No comments. 9721 and 9717. Page E -3 of 7 1 Requires Correction 6 * SAT OF = �`y P. Gonzalez �`� 0 , .4 4: PE #50746 • R S5 • • n in ri r. In T REP 1 ' T b. Condition: [ X ] Good [ ] Requires Repair c. Comments: Electrical panel in each location. 9. BRANCH CIRCUITS a. Identified: [ X ] Yes [ ] No, must be identified. b. Conductors: [ X ] Good c. Comments: No comments. 1 Deteriorated [ ] Must Be Replaced 10. GROUNDING OF SERVICE a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 11. GROUNDING OF EQUIPMENT a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 12. SERVICE CONDUITS/RACEWAYS a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 13. SERVICE CONDUCTORS & CABLES a. Condition: [ X ] Good [ ] Requires Repair TAT OF fenny P. Gonzalez �. ; Q : PE #50746 • • • erin r i s In P TI S RE S RT b. Comments: No comments. 14. WIRING METHODS, CABLES & CONDITION a. Types: [ X ] Conduit Raceways: [ X ] Good [N /A] Conduit PVC: [ ] Good [N /A] NM Cable: [ ] Good [N /A] BX Cable: [ ] Good b. Comments: No comments. 15. FEEDER CONDUCTORS a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 16. EMERGENCY LIGHTING [ ] Requires Repair [ ] Requires Repair [ ] Requires Repair [ ] Requires Repair a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: Emergency lights should be inspected periodically as part of routine building maintenance. 17. BUILDING EGRESS ILLUMINATION a. Condition: [ X] Good b. Comments: No comments. Page E -5 of 7 [ ] Requires Repair , [ ] None 6 G ngineering Groin, Inc. INSPECTION REPORT 18. FIRE ALARM SYSTEM a. Condition: [ ] Good [ ] Requires Repair [ X ] None • b. Comments: Fire alarm system is not required for as per Section 37.3.4 of the NFPA 101, Life Safety Code. 19. SMOKE DETECTORS a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: Refer to comments under item #18. 20. EXIT LIGHTS a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: Exit lights should be inspected periodically as part of routine building maintenance. 4110 21. EMERGENCY GENERATOR (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X] None b. Comments: N/A 22. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: No comments. 23. OPEN OR UNDERCOVER PARKING SURFACE AND SECURITY LIGHTING a. Condition: [ X ] Good [ ] Requires Additional [ ] None , ,%' "! • I 4k ST TE 0(F ; Benny P. Gonzalez '.9T 42,4 • '��;% PE #50746 Page E -6 of` , / o O R I p P NAL ��C • • • GNP Engineering Group, Inc. INSPECTION REPORT b. Comments: No comments. 24. SWIMMING POOL WIRING (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: N/A 25. WIRING TO MECHANICAL EQUIPMENT a. Condition: [ X] Good [ ] Requires Repair [ ] None b. Comments: No comments. Page E -7 of 7 =�Ir= TAT OF S OR 10 � �,���: S ' ONAL Benny P. Gonzalez PE #50746 GNP Engineering Group, Inc. 9723 NE 2 Avenue, Miami, Florida 40 -Year Recertification