Loading...
ELC-09-1519BUILDING PERMIT APPLICATION FBC 2004 Owner's Address 1.3 1.4( 4 City J.-- State et-- Tenant/Lessee Name E -MAIL: Qualifier Name E z,C:Liv'° Value of Work For this Permit $ ��✓� Describe Work: - rct- - 18(a-331 - L+so Miami Shores Village Building Department (0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit Type: Electrical Owner's Name (Fee Simple Titleholder)1.(( "t ( ' erP.ESz-t-l'rr---- Phone # 7&€ 33 ( 450c, Is Building Historically Designated YES NO Permit No. E LC "1 _O 157 C( Master Permit No. Zip 33 ( '7b Phone # Zip S? 1" Job Address (where the work is being done) 9 Q N - 'Z 4' City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # + 1 — 3 — i3— '24'G'b od -7,0 2609 98 Contractor's Company Name (A r-(l SC Phone # 7E54, 331 Q-c_r) Contractor's Address c t�e:;2S; ) t t 14 44 Cit ,,AL. state -�— Phone # —7 24, J ( 4. 1 State Certificate or Registration Nor--4.13Cr.:24 Certificate of Competency No. E- MAILeize �9 .: -. Architect/Engineer's Name (if applicable) Phone # Square / Linear Footage Of Work: Type of Work: ❑Addition L]Alteration ❑New ❑ Repair/Replace ❑ Demolition 12-4 coA-1— C4 (2c (rte ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Fees*************** * * * * * * * **** ****************************************Fees******************************************** Submittal Fee $ Permit Fee $ /Wee P CCF $ ' • 210 CO /CC —.-. Notary $* Training/Education Fee $ , 4 0 Technology Fee $ 1. 0 Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ 1 CP 5 . (0 V See Reverse side -3 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature er or Agent The foregoing instrument was acknowledged before me this t day of eQT , 2001, by who i ersonally kno to me or who has produced As identification and who did take an oath. My Commission Expires: ****************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** bra t* , tx * * **** ir, ti, tir*4t*ile*adrir9t******+ Y* ** **it*,t****,t****b******* APPLICATION APPROVED BY: (Revised 02/08/06) Signatur ontractor The foregoing instrument was acknowledged before me this day of 'gyp , 20 qby who iiersonally known119 me or who has produced as identification and who did take an oath. My Commission Expires: Plans Examiner Engineer Zoning Inspection Number: INSP - 124514 Scheduled Inspection Date: August 16, 2010 Inspector: Devaney, Michael Owner: COUNTY, MIAMI DADE Job Address: 9500 NE 2 Avenue Miami Shores, FL Project: <NONE> Contractor: BEST GARAGE DOORS INC Building Department Comments relocation of electrical circuits for overhead door motor controllers. Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments Norm GM( run b‘/ August 13, 2010 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 For Inspections please call: (305)762 -4949 Permit Number: ELC -9 -09 -1519 Permit Type: Electrical - Commercial Inspection Type: Final Work Classification: Addition /Alteration Phone Number (786)331 -4509 Parcel Number 1132060132660 Phone: (305)821 -9720 Page 1 of 26 REVISIONS BY: - 1 ,.t.,M, is MIAMI DAD FIRE SCU • • • • MIAMI SHORES FIRE•STAT4@Iy 30. .. 9500NE2AVE: • • • •• • o • • OVERHEAD BOOR REPLACEMENT PROJE8T • ••• • • • • ••• . . DATE 9/092009 SC.ALE: NTS DRAWN: R. ROJAS JOB NO: STA 30 OHD SHEET E -1 1 OF 1 SHEETS NOTE: EXISTING OVERHEAD DOOR CONTROLLER/OPERATOR TO BE REMOVED BY OTHERS UNDER SEPARATE PERMIT 120V 20A CIRCUIT IN 1/2° FLEXIBLE CONDUIT W/ 2-#12 THHN W/ 20 A 120V 1P DISCONNECT SWITCH FED FROM CIRCUIT EM-5 TO NEW OVERHEAD DOOR CONTROLLER (CONTROLLER TO BE INSTALLED BY OTHERS UNDER SEPARATE PERMIT) 120V 20A CIRCUIT IN 1/7 FLEXIBLE CONDUIT W/ 2-112 THHN W/ 20 A 120V 1P DISCONNECT SWITCH FED FROM CIRCUIT EM -7 TO NEW OVERHEAD DOOR CONTROLLER (CONTROLLER TO BE INSTALLED BY OTHERS UNDER SEPARATE PERMIT) 120V 20A CIRCUIT IN 1/7 FLEXIBLE CONDUIT W/ 2-#12 THHN W/ 20 A 120V 1P DISCONNECT SWITCH FED FROM CIRCUIT EM-4 TO NEW OVERHEAD DOOR CONTROLLER (CONTROLLER TO BE INSTALLED BY OTHERS UNDER SEPARATE PERMIT) 120V 20A CIRCUIT IN 1/7 FLEXIBLE CONDUIT W/ 2412 THHN W/ 20 A 120V 1P DISCONNECT SWITCH FED FROM CIRCUIT EM -2 TO NEW OVERHEAD DOOR CONTROLLER (CONTROLLER TO BE INSTALLED BY OTHERS UNDER SEPARATE PERMIT) EXISTING OVERHEAD DOOR TO BE REPLACED BY OTHERS UNDER SEPARATE PERMIT EXISTING 120V 20A CIRCUIT IN 1/2" EMT CONDUIT W/ 2-#12 THHN W/ 20 A 120V 1P DISCONNECT SWITCH FED FROM CIRCUIT EM -7 EXISTING 4"X4" JUNCTION BOX WITH 4414 THHN WIRES FOR CONTROL WIRING EXISTING OVERHEAD DOOR TO BE REPLACED BY ----� OTHERS UNDER SEPARATE PERMIT EXISTING 120V 20A CIRCUIT IN 1/7 EMT CONDUIT W/ 2412 THHN W/ 20 A 120V 1P DISCONNECT SWITCH FED FROM CIRCUIT EM-5 SCOPE OF WORK SECTIONAL OVERHEAD DOORS ARE TO BE REPLACED WITH NEW ROLL UP TYPE DOOR. EXISTING ELECTRICAL CONNECTIONS WILL BE REROUTED TO NEW OVERHEAD DOOR LOCATION. NO NEW LOADS WILL BE ADDED. ALL EXISTING LOADS WILL REMAIN THE SAME. - -- - ---------- -- -- -- - -- N EXTEND NEW CONDUIT AND WRING FROM EXISTING LOCATIONS TO NEW LOCATION ON WALL. NO EXTRA LOADS WILL BE ADDED EXISTING LOAD ON CIRCUIT WILL REMAIN THE SAME (TYPICAL) WATCH OFFICE WORK ROOM APPARATUS BAY C ELECTRICAL PLAN NOT TO SCALE NOT TO SCALE BUNKER GEAR --------------- r ELECTRICAL EXISTING OVERHEAD DOOR TO BE REPLACED BY OTHERS UNDER SEPARATE PERMIT EXISTING 120V 20A CIRCUIT IN 1/2" EMT CONDUIT W/ 2412 THHN W/ 20 A 120V 1P DISCONNECT SWITCH FED FROM CIRCUIT EM-4 EXISTING 4"X4" JUNCTION BOX WITH 4414 THHN WIRES FOR CONTROL WRING EXISTING 120V 20A CIRCUIT IN 1/2" EMT CONDUIT W/ 2412 THHN W/ 20 A 120V 1P DISCONNECT SWITCH FED FROM CIRCUIT EM -2 EXISTING OVERHEAD DOOR TO BE REPLACED BY OTHERS UNDER SEPARATE PERMIT EXISTING ELECTRICAL PANEL EM 120/240V 3P 4W 400A 0 4 LL 0 Q 00 1-- W • •••• • • •••• • • •• •• • • s • • • • ▪ • •• • •• ! • 1 • • a •• • • •• •• • • •• • • • • OR PRODUCED ID PRINT NAIVIE • • • • • • • • e• • • •• • • • • •••• • • • • • • ••• • • • • •••• • • • • • • •• •• • • • • • • • •••• • •••• • • •••• •• • • • • a • • • • • • e • • • am; Shores V il- ZONING DEP r1 T FLOG DES SUBJECT TO COMPLIANCE WITH ALL FEDERAL STaTF � ^; 7 � �� 1 NTy Ei! ES AND r.FGULATICNS