Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-09-1914
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 143279 Permit Number: RF -11 -09 -1914 Scheduled Inspection Date: May 14, 2010 Permit Type: Roof Inspector: Bruhn, Norman Inspection Type: Final Roof Owner: , Work Classification: Tile /Flat Job Address: 9475 NE 2 Avenue Miami Shores, FL 33138- Phone Number Parcel Number 113206013376 Project: <NONE> Contractor: SERVICE WORKS COMMERCIAL RO OFING, INC Phone: (813)626 -7717 Building Department Comments LOW SLOPE - FIRESTORE MODIFIED BITUMEN RE -ROOF STEEP SLOPE- OWNERS CORNING SHINGLE ROOF Inspector Comments Passed CREATED AS REINSPECTION FOR INSP- 142193. CREATED AS REINSPECTION FOR INSP- 129649. Termination metal and cap metal must be fastened per RAS 111 Failed ❑ ENTER THROUGH BANK. CHECK IN AND TAKE ELEVATOR TO ROOF. Correction ❑ Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. May 13, 2010 For Inspections please call: (305)762 -4949 Page 11 of 12 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 142193 Permit Number: RF -11 -09 -1914 Scheduled Inspection Date: May 12, 2010 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: , Work Classification: Tile /Flat Job Address: 9475 NE 2 Avenue Miami Shores, FL 33138- Phone Number Parcel Number 1132060133760 Project: <NONE> Contractor: SERVICE WORKS COMMERCIAL RO OFING, INC Phone: (813)626 -7717 Building Department Comments LOW SLOPE - FIRESTORE MODIFIED BITUMEN RE -ROOF STEEP SLOPE- OWNERS CORNING SHINGLE ROOF Inspector Comments Passed E:1 CREATED AS REINSPECTION FOR INSP- 129649. Termination metal and cap metal must be fastened per RAS 111 Failed IC> v 1J N o v Correction ❑ Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. May 12, 2010 For Inspections please call: (305)762 -4949 Page 17 of 25 f'_ I fvnfP"�i' g3rxfal,�'R�,O'.5� its A. d ��3 P..is Miami Shores Village �` s $� 10050 N.E. 2nd Avenue Miami Shores, FL 33138-0000'" Y 4 q Phone: (305)795 -2204 ,,� � •_ ... , .. ,. a oa Expiration: 061191201 Project Address Parcel Number Applicant 9475 2 Avenue 1132060133760 Miami Shores, FL 33138- Block: Lot: BANK OF AMERICA & DELOITTE Owner Inform Address Phone Cell BANK OF AMERICA & DELOITTE & TOU( P.O. BOX 182688 COLUMBUS OH 43218 - Contractor(s) Phone Cell Phone Valuation: $ 130,000.00 SERVICE WORKS COMMERCIAL ROC (813)626 -7717 Total Sq Feet: 10500 Type of Work: Re Roof For Inspections please call: Additional Info: FLAT ROOF &SHINGLE (305)762 -4949 Classification: Commercial Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Roof Review Roof in Progress Renailing Affidavit Cap Sheet Fees Due Amount Invoice # Total Amt Paid Amt Due CCF $78.00 RF -11 -09-36451 $ 726.00 $ 676.00 ��" Education Surcharge $26.00 -_> Permit Fee - New Roof $450.00 RF -11 -09-36451 $ 726.00 $ 726.00 $ 0.00 Scanning Fee $18.00 Check #: 3079 Submittal Fee $50.00 Technology Fee $ Total: $726.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. December 23, 2009 Authorized Signature: Owner / Applicant / Contractor / Agent Date Building Department Copy December 23, 2009 1 CFN 2009ROB52215 OR eK 97 Ps 215 (IPS NOTICE OF COMMENCEMENT RECORDED 11/3012009 13301 :02 HARVEY RUVINr CLERY. OF COURT: HIA11I -DADS COUNTYi FLORIDA LAST PAGE Permit No. Tax Folio No. 11 -3206-013-3760 Miaml -Dade County THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes, the following information is provided in this NOTICE OF COMMENCEMENT, l.Description of property (legal descrlpdon): Miami Shores SEC 1 AMD PB 10-70 LOTS 13-17 INC BLK 28 a) Street (job) Address: 9475 NE 2nd Avenue,-MI mi Shores Florida 33138 2.General description of improvements: Roofin 3.Owner Information a) Name and address: Bank of America, N.A., c/a CBRE, 6700 Lakeview Center Drive, Tampa, FL 33619 b) Name and address of fee simple titleholder (if other than owner) c) Interest in property 4.Contractor Information a) Name and address: Service Works Commercial Roofing, Inc., 5423 N. 59thSt., 2�a Zp FL 33610 b) Telephone No.: 813 - 626 - 7717 Fax No. (Opt.) 5.Surety Information a) Name and address: None b) Amount of Bond: c) Telephone No.: Fax No. (Opt.) 6.Lender a) Name and address: None Phone No. 7. Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served: a) Name and address: b) Telephone No.: Fax No. (Opt.) 8.In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13(1 Xb), Florida Statutes: a) Name and address: b) Telephone No.: Fax No. (Opt.) 9.Expiration date of Notice of Commencement (the expiration date is one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND F ED ON THE JOB SITE BEFORE THE FIRST INSPECTION.. IF YOU INTEND TO OBTAIN FINANCING, C SULt YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE COM E EMENT. STATE OF FLORIDA COUNTY OF PINELLAS 1 0 • Signature of or Owner's Authorized O icer re or /Manager Print Name The foregoing instrument was acknowledged before me this ay of Q , 20 O 1 by -50 r� U as dr C 1 (type of authority, e.g. officer, trustee, attorney In fact) for of sir M tAC— CA- (name of party on behalf f whom instrument was executed). Personally Known OR Produced identification I Notary Signature���X -- Type of Identification Produced /'Z A4 Ve 4 / i CC n fC-Name (print) �k"tl cao /3'l ' U Verification pursuant to Section 92.525, Florida Statutes. Under penalties of pei ju , I e �,, Jh�fasia�e�d i iY Ie the best of m ky nowledge and belief. EXPIRES: it21, 20�� s I --- — fins N*Wy PLft UndemOn Cn i n.Pi t �r ilk r ti Signature of Nat P n Signing (in line # 10.) Move iA!lTfdEo3.i HAFvE 'IN, CLE : , ofCfrc Sy l ® D.C. f � cou�yS =9 Miami Shores Village s l 8 20 ,.- r Building Department Y:_ ®o ® ® ®_. f0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 y� [4 BUILDING Permit No. 'k r PERMIT APPLICATION Master Permit No. FBC 2004 Permit Type (circle): Building Roofing Owner's Name (Fee Simple Titleholder) Bank of America, N.A. Phone # 813- 612 -6241. Owner's Address 6700 Lakeview Center Drive City Tampa State Florida Zip 33619 Tenant/Lessee Name Phone # Job Address (where the work is being done) 9475 NE 2nd Avenue, City Miami Shores Villaee County Miami -Dade Zip 33138 FOLIO / PARCEL # 11- 3206 - 013 -3760 Is Building Historically Designated YES NO XX Contractor's Company Name Service Works Creial Roofinq P one # 813 - 626 - 7717 /� Contractor's Address 5423 North 59th Street �� • 1 M City State Florida Zip 33610 Qualifier Name _ Jeffrey Todd Anderson Phone # 813 -245 -4352 State Certificate or Registration No. CCC1329134 Certificate of Competency No. Architect/Engineer's Name (if applicable) N/A Phone # Value of Work For this Permit $ 125, 267.00 Square ! Linear Footage Of Work: 8,400 Low Slope Area Type of Work: ❑Addition ❑Alteration ❑New ❑ Repair /Replace ❑ Demolition Describe Work: Low Slope — Firestone Modified Bitumen Re —Roof i as ees * *** ** Sub► l Fe � 6 LU e $ Permit Fee $ CCF $ �' CO /C Notary $ Training/Education Fee $ Technology Fee $ ' i Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse s -� 676 (�Axe Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Sign;reggoing Signature Owner or Agent Contractor The instrument was acknowledged before me this 2nd The foregoin Awas acknowledged before me this 3rd day of Nov. , 20 gam, by John Demo day of Nov. , 20 09, by Jeffrey R. Andersen who is personally known to me or � W& d who is personally known to me WQ6 N9T A &i gAd take an oath. as iffenli A ffi� oath. NOTARY PUB "' " Stlxanne N. Heater � NOTARY] "�" Suzanlae N. Heater Commission #DD791218 a �•. •Expires; SEP 13, 2 12 Commission #DD791218 • Expires: SEP 3, 2012 Sign: Sign: Print: Suz e N. Heater Pri nt: Suzann N. Heater My Commission Expires: 9/13/2012 My Commission Expires: 9/13/2012 i i APPLICATION APPROVED BY: Plans Examiner Engineer Zoning (Revised 07/10/07) i ♦SI RES Miami shores Village ,,,,, Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 ICRI>�, Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No: 09 -1914 Job Name: November 30, 2009 Page 1 of 1 Building Critique Sheet 1) All sloped roofs must be covered with color through tile. Shingles are not permitted. 2) Section A and C do not match the product approvals submitted. 3) Identify which approval is for each section to be reroofed. 4) Section C does not match engineering provided. 5) If a roof recover is proposed then an uplift test for the existing roof must be completed per FBC 1521. Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 11W Miami shores Village Kim o ,,,, Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 pR Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No: 09 -1914 Job Name: November 30, 2009 Page 1 of 1 Building Critique Sheet 1) All sloped roofs must be covered with color through tile. Shingles are not permitted. 2) Section A and C do not match the product approvals submitted. 3) Identify which approval is for each section to be reroofed. 4) Section C does not match engineering provided. 5) If a roof recover is proposed then an uplift test for the existing roof must be completed per FBC 1521. Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 Uaad SAM" ?! voaoxea 10050 NE 2nd Ave Miami Shores, FI 3313 ' Phone 305 - 795 -2204; Fax 305 -762 -5253 wiww.miamishoresvillage.com CONTRACTOR LICENSING/ REGISTRATION REQUIREMENTS FOR ALL CONTRACTORS TO REGISTER IN THE VILLAGE OF MIAMI SHORES THE FOLLOWING REQUIREMENTS ARE NEEDED: DADE COUNTY CONTRACTORS A. Certificate of Competency B. Dade Municipal Occupancy C. Dade Occupational Occupancy D. State Registration E. Liability Insurance Certificate F. Workers Compensation Insurance or Exemption STATE CONTRACTORS: A. i State License B. Occupational License C. Liability Insurance Certificate D. Workers Compensation Insurance or Exemption * * * * *** ** * ALL INSURANCE CERTIFICATES MUST BE MADE OUT TO THE FOLLOWING * * * * * *`* Miami Shores Village 10050 NE 2 AVE Miami Shores, FI 33138 ALL PERMIT APPLICATION REQUIRE THE QUALIFIERS NOTARIZED SIGNATURE Business Name: Service Works Ccmnercial Roofing, Inc. Business Address: 5423 North 59th Street, Tamm, Florida 33610 Business Telephone: (813)626-7717 Fax Number: ( 813) 626 -7248 Qualifier Name: Jeffrey Todd Anderson a . r r DETACH HERE Ac# r , , �� 4 6 4 2 � cT RIM ri`s.' .,.,rs"'1•- 1 , .� , 7 1 � j■�ti`� ,14 4 '•' -lam' =- `� •:".."".+•, �• ..41�vka e C - fi. �i' {° i ' ;�i�;` s e�T 4.glI ��..'^. ;f y 1rtK Fc-p tom; � ;.�- .�-� •� � _ �. R N - . -- _�, �'� f ' . : �... •^ '� S 1 ' :.�. . * =fi l" : h 7 40x019 , •'.$O : 3 �. x C 3 � '� '� C i Y>t' R n OF T0 �e'�"� •!+"r S F ,F 'v r ¢. Fy. } :T rm .t'� t � «4"s" � ` �l"4w 5�iY"1� Xn� r 4 � �� Y4i+ � � ^'s1 �' . ` � ` f�.. szderx'xe pvrxa Expiration date: `.AUQ 31, 2020 a s ; _ '- ,.� � � rF% X�.,� ' a i j r ! - t i #�'� ,, 3-F �` � � - _ "�s '� ( "` l � 'I'�r.. �1�* -�A• ��b.:- 'P f t S t `ts �,7 j o � t� •� 5 t SAt"z., : [p° �. r. �.� z r i ' t `t 'tT�..F'' Yi 5 s t : h 13' v W Il V_ AMC _ OMN E CI R RG FZX JXN, p t?eis.. 5 41M TAMPA u FL 3 3 6 .0 • :h'..+ r a ., e! F :a. J °'U g6_.,8�?� q f CI t•'f (/.}. !$( k, E .yfy�"= -p- . j - � ..+:. } °•. �d+r y� M� y,,,, {' -'.�•' e•`7. AMIFc1 ��*4°.*- ? iY# F Y 't' �. 3 „� extRLL, 'fit 3{ 0 t ES t w; S.ECR Y t 200992010 HILLSBOROUGH COUNTY BUSINESS TAX RECEIPT EXPIRES 9 - 2010 FOLIO NO. FACILITIES OR MACHINES 0 1 R OOMS 0 S 30 TS °'OB RENEWAL 170887.0000 0 H. WASTE TAX OCC. CODE BUSINESS TYPE SURCHARGE 090.023 ROOF1 IDI ''g'fff RE ED . . EET ME .. 40.00 54.00 BUSINESS 5423 N 59TH S7 LOCATION TAMPA 33610 NAME SERVICE WORKS COMMERCIAL ROOFIND'INC MAILING C/O JEFFREY T ANDERSON ADDRESS 5423 N 59TH ST TAMPA FL 33610 BUSINESS T” RECEIPT DOUG BELDEN, TAX COLLECTOR PAID - 27993 - 6 813435 -5200 07/24/2009 94.00 HAS HEREBY PAID A PRIVILEGE TAX TO ENGAGE THIS BECOMES A TAX RECEIPT WHEN VALIDATED. IN BUSINESS, PROFESSION, OR OCCUPATION SPECIFIED HEREON. P y ash - • e ACORD CERTIFICATE OF LIABILITY INSURANCE 11/0 M/DDIYYY1) 11/03/09 PRODUCER 1- 813 - 229 -8021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION M. E. Wilson Co., Inc. ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR 300 W. Platt St. ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Ste 200 Tampa, FL 33606 INSURERS AFFORDING COVERAGE NAIC # INSURED INSURERA:FIRST MERCURY INS CO 10657 Service Works Commercial Roofing, Inc. INSURER B: WESTFIELD INS CO 24112 5423 N. 59th Street INSURER C: BRIDGEFIELD CAS INS CO 10335 Tampa, FL 33610 INSURERD: INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. rA D' POLICY EFFECTIVE POLICY EXPIRATION g POLICY NUMBER LIMITS GENERAL LIABILITY FMGA000576 01/01/09 01/01/10 EACH OCCURRENCE $1,000,000 DAMAGE TO RENT X COMMERCIAL GENERAL LIABILITY PREMISES Eaocxurence $100,000 CLAIMS MADE 111 OCCUR MED EXP (Any one person) $Excluded PERSONAL &ADV INJURY $ 1,000,000 GENERALAGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER* PRODUCTS - COMP /OPAGG $2,000,000 POLICY $ P O- LOC B AUTOMOBILE LIABILITY CMK4651925 01/01/09 01 /01 /10 COMBINED SINGLE LIMIT X ANYAUTO (Eaaocdent) $1,000,000 ALL OWNED AUTOS BODILY INJURY $ SCHEDULED AUTOS (Per person) X HIREDAUTOS BODILY INJURY $ X NON -OWNEDAUTOS (Per accident) PROPERTYDAMAGE $ (Per accident) GARAGE LIABILITY AUTO ONLY -EA ACCIDENT $ ANYAUTO OTHERTHAN EAACC $ AUTOONLY: AGG $ A EXCESS/UMBRELLALIABIL17Y CUGA000055 01/01/09 01/01/10 EACHOCCURRENCE $5,000,000 X OCCUR El CLAIMS MADE AGGREGATE $ 5,000,000 DEDUCTIBLE $ RETENTION $ $ C WORKERS COMPENSATION AND 19614224 04/17/09 04/17/10 % T WCY LI EMPLOYERS'LIABILITY ANY PROPR DTH IETORf P ART E.L. EACH ACCIDENT $1,000,000 IETORlARTNER/EXECUTIVE OFFICER/MEMBEREXCLUDEDT E.L. DISEASE -EA EMPLOYEE $1,000,000 If yes, describe under SPECIAL PROVISIONS below E.L. DISEASE - POLICY LIMIT $1,000,000 OTHER DESCRIPTION OF OPERATIONS I LOCATIONS / VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT/ SPECIAL PROVISIONS Re: Jeffrey Todd Anderson, License No. CCC1329134 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION Miami Shores Village DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL 10050 NE 2nd Avenue IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. Miami Shores, FL 33138 AUTHORIZED REPRESENTATIVE USA . ACORD 25 (2001108) SH007 © ACORD CORPORATION 1988 13543212 j f Section A Roof areas 1, 4, and 5 NOA 08- 0716.04 MIAMI'DADE Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Section A (General Information) Master Permit No: Process No: Contractor's Name: Service Works Job Address: 9499 NE 2nd Avenue, Miami Shores, FL Roof Category ❑✓ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑Other. Roof Type ❑ New Roof ❑✓ Re- Roofing ❑ Recovering ❑ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes ❑✓ No If yes, what type? ❑ Natural ❑ LPGX Roof System Information Low slope roof area (ft. 2 , 300 Steep Sloped area (ft.z) Total (ft.2 _2,300 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): T6 Corner Size (a' x a'): T6 x T6 Section A Roof areas 2 & 3 NOA 08-0118.07 MIAM ADE Miami-Dade County Building Department Electronic Application � M1 M High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Section A (General Information) Master Permit No: . . . . ....... ------ I Process No: L ........ . .. . .......... . . ......... _71 Contractor's Name: [Servic Works Job Address: 19499 NE 2nd Avenue, Miami Shores, FL Roof Category Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ sprayed Polyurethane Foam ❑ Other: Roof Type ❑ New Roof ❑ Re-Roofing ❑ Recovering ❑ Repair ❑ maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes 91 No If yes, what type? ❑ Natural ❑ LPGX Roof System Information Low slope roof area ft 6,100 Steep Sloped area (M) I _ _ 7" 7_71 Total (ft -) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): Comer Size (a'x a'): 17'6 x T6 1 ... .... ..... Secfion A MIAMIjDMADE Miami-Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Section A (General Information) Master Permit No: L Process No: I Contractor's Name: Service Works Job Address: r9 NE 2nd Avenue, Miami Shores, FL Roof Category 21 Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile F/I Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑ Other: L Roof Type ❑ New Roof 0 Re-Roofing 1:1 Recovering ❑ Repair ❑ maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes Z No If yes, what type? ❑ Natural ❑ LPGX Roof System Information 1[ Low slope roof area (ft 9 ,100 Total (ft 2) 10,500 8,400 Steep Sloped area (ft.2) Section B Moof, 2 y , Sketch Roof Plan: Illustrate all levels and sections, roof drains, s§uppf e sc ppets and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of eevat p u zo d location of parapets. Perimeter Width (a'): T6 Comer Size (a'x a'): T6 1 6 s o* 000 0*0 ••• ••• ••• • ••• • • ... . • •• • • • • • • • •�• • • • • • • • • • • • •• • • • • • •• •• •s• • • • •• • • • • •• •�• • • •�• e • • • • • • • • • •�• • • • • • • • • • • • • •�• • • • • • • • • •• •• •� • • • • • • • • • • • • • • • •• • • • •• • • • • • • • • • • • •�• • • • • • • • • • • • • • • • • • • • • •• d r i l e � � t AREA 5 NOT INCLUDED r - %��� 7 6 ELEVATED PRESSURE ZONE i + = EXISTING ROOF AREA 2 DRAIN j EXISTING / r OVERFLOW DRAIN Q W p f A J Z NOA OS- 0716.0+ APPLIES TO TO AREAS Z 1, 4, AND S 47' Z Z } NOA 08- 0118.07 APPLIES TO AREAS / 2 AND 3 r. AREA 1 1 1-171 m NOT INCLUDED NOT INCLUDED Job Nome BANK OF AMERICA 9449 NE 2ND AVENUE AREA 4 /i ' ' MIAMI SHORES, FL $gRV,ICV . WORKS £ n No. , / YOUR FULL SERY)CE ROOFtNQ CONTRACTOR AREA 3 — 5423 N. 59th Street Tampa, FL 33610 pate scale FHe Phone 12/8/o9 NTS BOA MIAMI SHRS.TCW Fax 613 -626 3.626 -7248 7248 AREA 5 ry NOT INCLUDED � w s = 7' 6 ELEVATED FIZE99URE ZONE + = EX19TINCo ROOF AREA 2 DRAIN = EX19TING OVERFLOW DRAW Q p W _ 0 Q J J v v ? 0 47 ' 2 Z 5' • 0.00 �. AREA 1 0000•• •.•• • • m • • 0000•• 0.004• • 40 •• •• •040• 4 •• •04.00 0000• • 0400 0000•• • • •000•• • 4 • • 0000 • • • •• ••• • 00000• • 00000 4 , NOT INCLUDED NOT INCLUDED . . Job Nam BANK OF AMERICA 9499 NE 2ND AVENUE AREA 4 MIAMI SHORES, FL Dmwhig Q ( �� Yv�l f �f 1C� FIND CONTRACT R ' NO. R8VI310� AREA 3 5423 N. 59th street Tampa, FL 33810 pate scats File Phone 813-828 -7717 U/2/09 NTS BOA MIAMI SHRS.TCW Fax 813.828.72,0 { i x . . .• . • • .. ... .. . . . .. . .. . . . . ... . 1 T Swim C Roof areas 2 & 3 MIAM F Miami -Dade County Building Department Electronic Application s High Velocity Hurricane Zone Roofing Permit Application Form "Deliveri ng Excellence Every Day" Section C page (Low Slope Roof Systems) Fill in the specific roof assembly components. /f a component is not required, Insert not applicable (We) In the text box. ROOF SYSTEM MANUFACTURER: I Firestone Top Ply: - APP 180FR (1) 08-011$.07 _ — Product Approval (NOA): _. _ System Type MB _ ', Top Ply Fastening /Bonding Material: Wind Uplift Pressures, From RAS 128 or Sealed Calculations: Asphalt (P1) Feld: 1 psf Surfacing: SINGLE PLY MEMBRANE: (P2) Perimeters: 98 psf Single Ply Manufacturer / Type: (P3) Comers: 151 psf Maximum Design Pressure From NOA: 52.5 psf Fastening #2 g Single Ply Sheet Width: 112 Sheet Width: Roof Slope: 1 /$ ". " :12 Roof Mean Height: 32 .., ft No. of Single Ply 1/2 sheets: NA Parapet Walls: 0 No ✓M Yes Parapet wall Height: 3 ft. Single Ply Membrane Fastening / Bonding Material: Deck T y 5/8" Plywood _..... _ _ _.. FASTENER SPACING FOR BASESHEET ATTACHMENT Support Spacing: 24 _ " o1c ❑ SINGLE PLY MEMBRANE ATTACHMENT Alternate Deck Type: _ _......_ _ _ _ _ E)dsting Roof 1. Field: E - o1c @Laps & LLJ rows E " o1c Built up roof w/ gravel surfacing 2. Perimeter - o/c @ Laps & 4 rows 6 r. 6 -. " o% Fire Barrier. NA 3. Comer. El " olc @ Laps & 5 rows 6 " o1c Vapor Barrier. NUMBER OF FASTENERS PER INSULATION BOARD: NA 1. Feld: Li 2. Perimeter. El 3. Comer. Anchor Sheet: Insulation Fastener Type: : NA Anchor Sheet Fastener / Bonding Material: WOOD NAILER TYPE AND SIZE: .. ... Insulation Base Layer Size & Thickness: 2x$PT _....... .. _ NA Wood Nailer Fastener Type and Spacing: Insulation Base Layer Fastener/ Bonding Material: I Two rows stagered at 1ti o.c. with #14 x 3" hex head s INA EDGE & COPING METAL SIZES: Insulation Top Layer Size & Thickness: Edge Metal Material: Aluminum — Edge Size: Insulation Top Layer Fastener / Bonding Material: Hook Strip Size: —0.050 NA Edge Metal Attachment: Base Sheet(s) & No. of Ply(s): Stager nailed at 4" ox. with 129a SS ring shank nails MB Base Sheet (1) _. _.... _ ...... -- _ Base Sheet Fastener / Bonding Material: Coping Material: Aluminum- - 1.25" galvanized roofing nails and tin caps Coping Size: - 4 " face 0.040" Ply Sheet(s) & No. of Piy(s): APP 160 1 Hook Strip Size: —0.050 - - -- _ �) Parapet Coping Metal Attachment: Pry Sheet Fastener / Bonding Material: Stager nailed at 4 o.c. with 12ga SS ring shank nails Asphalt Back face of coping attached with SS 1.5" self drilling wood screws and rubber grometed washers. Section C r r ti Roof areas 2 & 3 MIAMMAM&I Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form 11 0eh`ver3'ng Excellence Every [Jay" Section C page (Low Slope Roof Systems) Fill in the specfic roof assembly components. if a component is not required, insert not applicable (n!a) in the text box. ROOF SYSTEM MANUFACTURER: Firestone Top Ply: App 180FR (1) Product Approval (NOA): 08- 0118.07 1 Sy stem Type: MB Top Pty Fastening / Bonding Material: Wind Uplift Pressures, From RAS 128 or Sealed Calculations: Asphalt (P1) Field: 154 1 psf Surfacing: g8 SINGLE PLY MEMBRANE: (P2) Perimeters: psf Single Ply Manufacturer / Type: (P3) Comers: 1151 1 psf NA Maiamum Design Pressure From NOA: 52.5 psf Fastening #2 Single Ply Sheet Width: 1/2 Sheet Width: Roof Slope: 1 / 8 " " : 12 Roof Mean Height: 32 it No. of Single Ply 1/2 sheets: I NA Parapet Walls: R] No M Yes Parapet wall Height: [< 3 ft. Single Ply Membrane Fastening / Bonding Material: NA Deck Type: —5/8" Plywood — FASTENER SPACING FOR BASESHEET ATTACHMENT Support Spacing: 124 " o% ❑ SINGLE PLY MEMBRANE ATTACHMENT _ Altemate Deck Type: I NA 1. Field: " o/c @ Laps & 2 6 rows 6 " o/c E)dsting Roof: Built up roof w/ gravel surfacing 2.nm #''e# " o/c @ Laps & LLJ rows 6 - 0/c Fire Barrier NA 4 , y 3 E�me i ' ' " o/c @ Laps & 5 rows 6 " o/c NUER *' STENERS PER INSULATION BOARD: Vapor Barrier. NA 1. Fleld:0 2. Perimeter. 3. Comer. Anchor Sheet: Insulation Fastener Type: . NA � Anchor Sheet Fastener! Bonding Material: WOOD NAILER TYPE AND SIZE: Insulation Base Layer Size & Thickness: 7 Wood Nailer Fastener Type and Spacing: i t 16" d tagere a o. c. with #14 x 3" hex head Two s Insulation Base Layer Fastener /Bonding Material: rows s _ NA EDGE & COPING METAL SIZES: Insulation Top Layer Size & Thickness: Edge Metal Material: Aluminurr Edge Size: —4" face 0.040" — Insulation Top Layer Fastener/ Bonding Material: Hook Strip Size: 1 --0.050" — Edge Metal Attachment: Base Sheet(s) & No. of Ply(s): Stager nailed at 4" o.c. with 12ga SS ring shank nails MB Base Sheet (1) -- Base Sheet Fastener / Bonding Material: Coping Material: AlurrNnuKn• • • . • • 1.25" galvanized roofing nails and tin caps Coping Size: - A*fag% 0APO— 0 . • : : .. • Ply Sheet(s) & No. of Ply(s): — 0.050 " — Hook Strip Size: 1 APP 160 (1) Parapet CopinB,MetW Attachnfent:... ... ... Ply Sheet Fastener/ Bonding Material: Stager nai�tlatsl "p.c WIi•12 S rin sha k nails Asphalt -.... Back face of co ink attached with SS 1.5 self drilling wood screws and ... . . i4i .. . rubber g4om*te� sY . ... . . . .. . . ...... . .... a 000 f 1 � . . . . . . . . . • • • • • • • • • • • • • •• •• •• • • . • . ♦ • • • •. • . • ♦ .♦i • f 1 � a Section C Roof areas 1,4, and 5 MIAM Miami -Dade County Building Department Electronic Application ® High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Section C page (Low Slope Roof Systems) Fill in the speck roof assembly components. /f a comment is not required, insert not applicable (n/a) in the text box. ROOF SYSTEM MANUFACTURER: I Fir estone Top Ply: - APP 180FR (1) : Top Ply Fastening / Bonding Material: Produd Approval (NOA): Ot3 0716.01 System T MB Wind Uplift Pressures, From RAS 128 or Sealed Calculations: Asphalt (P1) Feld: psf Surfacing: (P2) Perimeters: SINGLE PLY MEMBRANE: psf Single Pty Manufacturer/ Type: (P3) Comers: _ ._ . psf INA Maximum Design Pressure From NOR: X2.5 psf Single Ply Sheet Width: " 112 Sheet Width: " Roof Slope: 118 - :12 Roof Mean Height: 22 No. of Single Ply 112 sheets: K Parapet Walls: 0 No 0 Yes Parapet wall Height: Single Pty Membrane Fastening / Bonding Material: Deck Type: — Structural Concrete — ❑ FASTENER SPACING FOR BASESHEET ATTACHMENT Support Spacing: _ " otc ❑ SINGLE PLY MEMBRANE ATTACHMENT Alternate Deck Type _..... __.._._. _.. __ _.,. 1. Field: "o/c @Laps & _ -_ rows "o /c F�cisting Roof: Built up roof w/ gravel surfacing 2. Perimeter. " olc @ Laps & LJ rows ' " o/c Fire Barrier I NA 3. Comer. _ " o/c @Laps & rows " o1c Vapor Barrier. NUMBER OF FASTENERS PER INSULATION BOARD: 1. Feld: - 2. Perimeter. Li 3. Comer. Anchor Sheet: Insulation Fastener Type : Tite Set Insulation Adhesive at 12" o.c. Anchor Sheet Fastener! Bonding Material: WOOD NAILER TYPE AND SIZE: 8PT Insulation Base Layer Size & Thickness: 2 x.. .. _ .. ....._ _.. _ 4' x 4' x 2" isocyanurate Wood Nailer Fastener Type and Spatting: Insulation Base Layer Fastener /Bonding Material: T wo rows stagered at 16" o.c. with #14 x T hex head _ _ _ ._._... _ _ _ .. _. Tite Set Insulation Adhesive EDGE & COPING METAL SIZES: Insulation Top Layer Size & Thickness: Edge Metal Material: Aluminum -- 4' x 4' x .25" Securerock _..__ .. Edge Size: --4" face 0.040 " — .._ __ _ _._ __. Insulation Top Layer Fastener / Bonding Material: Hook Strip Size: Tito Set insulation Adhesive Edge Metal Attachment: Base Sheet(s) & No. of Ply(s): Stager nailed at 4" o.c. with 12ga' SS ring shank nails MB Base SA base sheet (1) Base Sheet Fastener/ Bonding Material: Coping Material: Aluminum — Self adhering Ply face 0.040 " — Coping Size: _ . _ Ply Sheets) & No. of Piy(s): — 0.050 "_ APP 160 (1) Hook Strip Size: _.. _ Parapet Coping Metal Attachment: Ply Sheet Fastener / Bonding Material: Stager nailed at 4 o.c. with 12ga SS ring shank nails Asphalt Back face of coping attached with SS 1.5" self drilling wood screws and rubber grometed washers. secum C , r r Roof areas 1,4, and 5 MIAMM Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form "®elivering Excellence Every Day" Section C page (Low Slope Roof Systems) Fill In the specHlc roof assembly components. if a component Is not required, Insert not applicable (nla) in the text box. ROOF SYSTEM MANUFACTU X- Firestone Top Ply: APP 180FR (1) Product Approval (NOA): 0 .03 S T MB Top Ply Fastening / Bonding Material: Wind Uplift Pressures, Fr m RAS 128 or Sealed Calculations: Asphalt (P1) Field: 1 1 psf Surfacing: SINGLE PLY MEMBRANE: (P2) Perimeters: 198 1 psf Single Ply Manufacturer/ Type: (P3) Comers: 1151 1 p NA Ma)amum Design Pressure From NOA: 262.5 psf Single Ply Sheet Width: " 1/2 Sheet Width: " Roof Slope: 118" " :12 Roof Mean Height: ft. No. of Single Ply 1/2 sheets: UA Parapet Walls: 0 No 0 Yes Parapet wall Height: 1 3 1 ft. Single Ply Membrane Fastening / Bonding Material: NA Deck Type: I —Structural Concrete -- ❑ FASTENER SPACING FOR BASESHEET ATTACHMENT Support Spacing: " o/c ❑ SINGLE PLY MEMBRANE ATTACHMENT Alternate Deck Type: 1. Field: " o/c @ Laps & rows " o% Existing Roof: Built up roof w/ gravel surtacing enmeter, " o% @Laps & rows o/c o/c Fire Barrier. f, , ✓ o ", ' 3u' ome . " o% @ Laps & rows " o% Vapor Barrie ? 4 �,;,~ N�IBE QF ; A TENERS PER INSULATION BOARD: Barrier �> k � a ; NA 1. Field: 2. Perimeter. Li 3. Comer. Anchor Sheet: Insulation a n r Type INA Tit I s lion Adhesive ive in 3.5" ribbons at 12" o.c. Anchor Sheet Fastener / Bonding Material: j INA D ILER TYPE AND SIZE: Insulation Base Layer Size & Thickness: jd 1 4' x 4' x 1.5" isocyanurate EW0 d Nailer Fastener Type and Spacing: Insulation Base Layer Fastenerl Bonding Material: o rows stagered at 16" o.c. with #14 x 3" hex head s Tite Set Insulation Adhesive EDGE & COPING METAL SIZES: Insulation Top Layer Size & Thickness: Edge Metal Material: —Aluminum - 4' .25" Securerock Edge Size: -4" face 0.040" — Insulation Top Layer Fastener/ Bonding Material: Hook Strip Size: - 0•050 " — Tite Set Insulation Adhesive Edge Metal Attachment: Base Sheet(s) & No. of Piy(s): Stager nailed at 4" o.c. with 12ga SS ring shank nails MB Base SA base sheet (1) Base Sheet Fastener/ Bonding Material: Coping Material — �urriiAm: • • : : • Self adhering Coping Size: Ply Sheet(s) & No. of Ply(s): Hook Strip Size: — 0.050 " — APP 160 (1) Parapet Copiryg,MetpI Attach%pent; Ply Sheet Fastener/ Bonding Material: Stager na a 4ryo.. with 12 a SS ri shank n As ails phalt • . . • • . .. •. • • Back fdce 'of cdpir att'ach'ed with SS 1.5" self drilling wood screws and ... . . ...... . rubber gror0etE:d: Ws$e3V ; . . .... . . . . . ...... . .... 000 • • • 000 • • ... . . . ... . . .. .. . . . .. ... . . . . ... . .... . .. .. .. .. . . ... ... G .. ... .. . . . .. . .. . . . . ... . .. ... . . . . . .. y x c Shingle Roof System , Area 6 MIAM Miami -Dade County Building Department Electronic Application Section D Sloped System Description ` Shingle Roof System "Delivering Excellence Every Day"' Roof System Manufacturer: Owens Coming Notice of Acceptance Number: 05- 1213.02 Fitt in the speck r roof assembly components. ff a component is not required, insert not applicable (n/a) in the text box. 5/8" Deck Type: Plywood Optional Insulation: NA Optional Nailable Substrate: NA _ Optional Nailable Substrate Attachment: NA UnderlaymentBase Sheet Type: Roof Slope: 5 11/12" 30# felt tFasik for Basesheet Attachment: Roof Mean Height: 132 1 ft. w N and tin tabs I (Maximum roof mean height 33 ft) A Pt' al Peel & Stick Membrane: Optional Ridge Venting: O Yes O No NA i Shingle Type: Ridge Vent NOA Number. NA Oakridge PRO 40AR Installed Ridge Venting: INA I lineal ft. Drip Edge Size & Gauge: I —Select Drip Edge Size— NA Installed Ridge Venting: NA ft. Drip Edge Material Type: — Select Drip Edge Material— NA Existing Soffit Intake: NA ft 2 Drip Edge Fastener Type: .. ••. • • • .• Note: In no case shall the amount of exhaust • NA . .. • ...... .. . ventilation at the ridge exceed the amount of Hook striplC►e&?gaup or eveighty • • • soft ventilation. — Select Hook Strip- NA • • • % .. .. ..... . . •• . . . . . . . . . •• .. • • ••• . • • • • • • . .... .... . . .... . c , r . .. .. . . . .. .. . •. ... J . . . . . . . . . . • • • 00 00 *0 0 0 : 0 0 0 . .. . • . • ... • •• ••• • • • • • •• c , r Section C2d f ' Y Area 3 and 4 MIAMIFDADE Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations /Stripping /Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. 1.5 IL 2?_.._.. IL 00 0 • • . • . • • • 0 00 op L 00 " 00 so 0 • • • • . • • 00 • . • • Coping Metal Cot aft to Deck r Area 3 and 4 MIAMM Miami -Dade County Building Department Electronic Application MMW High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Fxc ellem Ever Day" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations /Stripping/Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. COPING METAL 'U 1 Parapet wall height: 1 5 % CONT. CLEAT 7 GUAGE HEAMER PT WOOD BLOCKING Roof Mean Height: ft. SCREW W Coping Metal: �--,� SEALING WASHER ,040 aluminum ,-BASE FLASHING Cleat: aluminum - - - Wood Nailer: �- Wood Nailer Fastening: Two rows staggered at 16" o.c. with #14 x3" Base Flashing: 4 ,d TOP PL's APP 160 (1) and APP 180FR (1) _ - INTERPLIES Surfacing: • - BASE SHEET NA am :. _ Top Ply: APP 180FR R �► ¢ Ply Sheet: 8 - APP 160 ' - l t ' ASTM PRIMER Base Sheet: 3 d - ° MB Base SA base sheet _ - Top Layer of Insulation: ' ANCHOR SHEET J .25" Securerock - CANT STRIP -_ Base Layer of Insulation: TOP LAYER INSULATION 1. is ale , - BASE LAYER INSULATION AhLI<ior%ed: ' ° • ° • CONCRETE DECK ..... . . . . . . . . • • • .. % .. I . ..... . ... . .. .. . . • ♦• •• .... . . .... . Edge Nailable Deck R , Area 5 MIAMI Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations /Stripping /Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. Top P ly Interplies Base Sheet Roof Mean Height: 22 ft. Drip Metal: .040 aluminum Surfacing: Chip Metal NA Top Ply: I APP 180FR Interplies: 4 JAPP 160 Base Sheet: Roof Deck 4. - V MB Base SA - Deck Ty � Structural concrete ....... . .. .. . . ......... . .. ... .. . .... .. . . ... ...... ..... . . . . . .... ....... . ..... . ... . ...... . .... { i i t ' SECTION 1524 HIGH - VELOCITY HURRICANE ZONES- - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Cade, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. T,D 1. Aesthetics- workmanship The workmanship provisions of Chapter 15 (High - Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailoi in accordance with the current provisions of Chapter 16 (High - Velocity Hurricane Zones) of the. (The roof deck is usually concealed prior to removing the existing roof system.) 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to - be performed. _ 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nall;penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a buildup of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. — J D 7. Ventilation: Most roof structures should have p`ome 1 tQ ver-t gatural airfkow through the interior of the structural assembly (the building rtsplf) ? 1rtV p4sfjnQ1'4md4nt of attic ventilation shall not be reduced. it may be beneficial to cbhs!Mf adtdltioftal'Vdrift which can result in extending the service life of the roof. o� ... Own s /Agent`s gnature Date n s Signature DaDa e .. . ....... . . ..... . .. . . .... . .... .... . .... . v I �a MIAMI DADE COUNTY, FLORIDA BUILDING CODE COMPLIANCE OFFICE ( BCCO ) METRO -DARE FLAGLER BUILDING PRODUCT CONTROL DIVISION 140 WEST FL►GLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 NOTICE OF ACCEPTANCE OA ( 375 FAX (305) 375 Firestone Building Products Company 310 East 96 Street Indianapolis, IN 46240 -3702 Rl 1 SCOPE: This NOA is being issued under the applicable rules and regulations governing th use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority laving Jurisdiction (AHJ). I This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance put�ses If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. DORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Firestone Modified Bitumen Self Adhered Roof Systems over Concrete Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or lo go, city, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted sta herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA Supercedes NOA No. 08- 0118.01 and consists of pages I through 15. The submitted documentation was reviewed by Jorge L. Acebo. f NOA No.: 08 -0716.01 ECO�mr Expiration Date: 06/26/13 ]APPR Approval Date: 08/21/08 Page 1 of 15 ROOFING SYSTEM APPROVAL Ca o - Roofing Su —b off? Modified Bitumen Material• APP /SBS Deck Tvoe. Concrete Maximum Design Pressure -540 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Ennensions Spec; Description APP 180 39.4" x 3Tl 0" ASTM D 5147 Polyester reinforced modified bitumen granule APP 180 FR surfaced membrane. Torch applied. 39.4" x 32'10" ASTM D 5147 Polyester reinforced, fire retardant modified bitumen, granule surfaced membrane. Torch APP 170 39-4"x336" ASTM D 5147 Polyester reinforced modified bitumen APP 160 membrane. Torch applied. 39.4" x 32' I O" ASTM D 5147 Polyester reinforced modified bitumen membrane. Torch applied MB Base SA Sheet 36" x 108' ASTM D 5147 Fiberglass reinforced base sheet, asphalt coated on both sides with a plastic release film on the underside. SBS Premium FR 39.4"x33'10" ASTM D 6164 Ceramic granule surface, fire rated, modified Torch bitumen membrane with a bum -off film and Rhoflex FR reinforced with non -woven polyester mat. ASTM D6223 Glass/Polyester reinforced modified bitumen Granule cap sheet APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer ISO 95+ GL (With Current NOA) Isocyanurate Insulation Firestone Dens Deck Prime Silicon treated gypsum G -P Products Securock Fiber Reinforced Coverboard USG Corp. NOA No.: 08- 0716.01 ►aa+Hnaoecourmr� Expiration Date: 06/26/13 APPROVED i Approval Date: 08121!08 Page 2 of 15 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Firestone All- Purpose Insulation and membrane Various Firestone Fastener # 15 fastener 2. Firestone HD Fastener Insulation and membrane Various Firestone #15 fastener 3. Firestone Concrete 1/4" diameter concrete deck Various Firestone Drives fastener. 4. MB Barbed Metal Metal plates used for 2" dia Firestone Seam Plate membrane securement. 5. Hexagonal Plate Insulation attachment 3%" x 2- Firestone hexagonal plate 7 /8" 6. Seam Plate Membrane seam attachment 2j/g" dia Firestone plate. 7. Metal Plate Membrane attachment plate. 2" dia Firestone 8. Insulation Fastening Insulation plate for use with 3" round Firestone Plate Firestone Fasteners EVIDENCE SUBMITTED: Test Atency Test Identifier Description Date Factory Mutual Research Corp. 3022492 FM 4470 01/17105 3028093 FM 4470 10/26/07 3020395 FM 4470 11/29/04 3014537 FM 4470 11/29/04 3012321 FM 4470 07/29/02 3015692 FM 4470 08/05/03 Trinity I ERD F7370.11.07 FM 4470 / TAS 114 11/22!07 F8800.01.08 -R1 ASTM D 903 / TAS 114 01/17/08 F10370.05.08 ASTM C 1289 05/08/08 PRI Asphalt Technologies FBP- 011 -02 -01 ASTM D 6164 09/02/04 FBP- 008 -02 -01 ASTM D 6222 09/10/04 FBP- 009 -02 -01 ASTM D 6222 08/31/04 FBP -015 -02 -01 ASTM D 6509 09/02/04 FBP - 023 -02 -01 ASTM D 6223 09/01/04 FBP- 007 -02 -01 ASTM D 6222 09/14/04 NOA No.: 08- 0716.01 Expiration Date: 06/26/13 MUkMH)AMCOQNWM Approval Date: 08/21/08 Page 3 of 15 Membrane Type: SBS Deck Type 3L• Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(5): Insulation adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Layer Insulation Fasteners Fastener f ni GL (Table 3) Density /fe u 2" thick N/A N/A Base ' Ion layer shall be adhered to the deck with OlyBoud at a rate of 1 gal/sq. or OlyBond 500, Firestone I.S.O. FTX M Firestone I.S.O. Twin Pack or Polyfoam Tite -Set in ribbons 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners Fastener gO5iO (Table 3) Density/fe thic N/A N/A tion layer shall be adhered with OlyBond at a rate of 1 gal/sq. of Firestone I.S.O. FIX IQ, Firestone I.S.O. Twin Pack or Polyf -. i ribbons 12" o.c. Please refer to Roofing Application Standard RAS 117 for insnlati ent. Note: Securock shall be primed with ASTM D41 asphalt primer or Firestone SA primer and allowed to dry prior to application of base sheet Base Sheet: One or more plies of Firestone MB Base SA self - adhered to cover board Membrane: One ply of Firestone SBS Premium FR Torch torch applied. Surfacing. (Optional) Install one of the following to obtain required fire classification. 1. Gravel or slag at 4001bs/sq or 300 lbs/sq, respectively, in a flood coat of approved asphalt at 60 lbs/sq. 2. Karnak 97 Fibrated Aluminum Asphalt Roof Coaxing or Asbestos Free Aluminum Roof Coating at 1' /Z gal/sq. 3. Kokem Products Sunguard Acrylic Roof Coating at 1 gaVsq. 4. Money Endure Aluminum Roof Coating, Weather Check or Pro -Grade Aluminum Roof Coating at 1 %a gal/sq. 5. Grundy al MB Aluminum Roof Coating at 1 -2 gal/sq. 6. Fields F350 Heat Shield Aluminum Coating or F630 Heat Shield Fbered Aluminum Coating at I V2 gal/sq. Maximum Designsf with OlyBond (See General Limitation #9) Pressure: 2 sf with all other insulation adhesives (See General Limitation #9) NOA No.: 08-0716.01 r naan n�►oF c Expiration Date: 06!26/13 Approval Date: 08al /08 Page 8 of 15 CONCRETE DECK SYSTEM LEVHTATIONS: I. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant. GENERAL LEWrATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area Of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every IT in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 Ibs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from 'Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 Will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, Perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 08-0716.01 rEwr+waouaaECaunnr Expiration Date: 06/26/13 '• Approval Date: 08121/08 Page 15 of 15 • 1 1 r r r r r MIAMI �DADE IA MMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) I40 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE (NOA) Firestone Building Products Company 310 East 96"' Street Indianapolis, IN 46240 -3702 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Firestone Modified Bitumen Roof Systems over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state i and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted j herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job sit %at Vwequest gf tlr, $uildipg Official. This NOA revises NOA No. 05- 0830.10 and consists of page9 d th?4u4h S0; ; •; • The submitted documentation was reviewed by Jorge L. Ace%. * ' ' • • • V M 08- 0118.07 Expiration Date: 03/08/11 • . ... . . • . ...Approv al Date: 07/10/08 i ;.; Page 1 of 30 . ... • 0 0 000 . . ROOFING SYSTEM APPROVAL , Category: Roofmg Sub - Category: Modified Bitumen Material: APP /SBS Deck Type: Wood Maximum Design Pressure -52.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description APP 180 39.4" x 32'10" ASTM D 6222 Polyester reinforced modified bitumen, granule surfaced membrane. Torch applied. APP 180 FR 39.4"x32'10" ASTM D 6222 Polyester reinforced, fire regardant modified bitumen, granule surfaced membrane. Torch applied. APP 170 39.4" x 33'6" ASTM D 6222 Polyester reinforced modified bitumen membrane. Torch applied. APP 160 39.4"x32'10" ASTM D 6222 Polyester reinforced modified bitumen membrane. Torch applied. MB Base Sheet 36" x 108' ASTM D 4601 Fiberglass reinforced base sheet, asphalt coated on both sides. Applied in hot asphalt or mechanically attached. MB Base M 39.4" x 98.7' ASTM D 4601 Fiberglass reinforced base sheet, asphalt (1 in x 30.1 m) coated on both sides. Applied in hot asphalt or mechanically attached. SBS 39.4" x 33'10" ASTM D 6164 Granule surfaced, modified bitumen membrane reinforced with non -woven polyester mat. SBS FR 39.4" x 33'10" ASTM D 6164 Ceramic granule surface, modified bitumen membrane reinforced with non -woven polyester mat. SBS Premium 39.4" x 33'10" ASTM D 6164 Granule surfaced, modified bitumen membrane reinforced with polyester mat. Applied in hot asphalt. SBS Premium FR 39.4" x 33'10" ASTM D 6164 Ceramic granule surface, fire rated, modified bitumen membrane reinforced with non -woven polyester mat. SBS Base Sheet 39.4" x 50' ASTM D 6163 Fiberglass reinforced SBS base sheet. Applied in hot asphalt or mechanically attached. SBS Smooth 39.4" x 33'10" ASTM D 6164 , Sindft $Nrfagd. mW; d-bitumen memblary tigf" pvitll, non -woven • puler aW A'pp7id2i ipliot asphalt. SBS Glass Torch Base 39.4"x33 ASTM D 6163 Modified bitumen base sheet with a bum- .. off film a4d re foreq with non -woven :. fibdlglast fat. ; . . • • • • ' ' •' : MA :qo.: 08- 0118.07 Expiration Date: 03/08/11 t M c ► Approval Date: 07/10/08 j • : : : : ':' ; ; Page 2 of 30 ••• • • • ••• • • Test Product Product Dimensions Specification Description SBS Premium FR 39.4" x 33'10" ASTM D 6164 Ceramic granule surface, fire rated, Torch modified bitumen membrane with a burn - off film and reinforced with non -woven polyester mat. SBS Glass 39.4" x 33'10" ASTM D 6163 Fiberglass reinforced, granule surfaced, modified bitumen membrane. Applied in hot asphalt. SBS Glass FR 39.4"x33'10" ASTM D 6163 Granular surfaced, fiberglass reinforced, fire regardant, modified bitumen membrane. Applied in hot asphalt. Rhoflex Base Sheet ASTM D6509 Asphalt coated glass fiber base sheet Rhoflex FR Granule ASTM D6223 Glass/Polyester reinforced modified bitumen cap sheet Type IV 33" x 180" ASTM D2178 Fiberglass reinforced, asphalt impregnated, roofing ply. Applied in hot asphalt. Type VI 33" x 180" ASTM D2178 Fiberglass reinforced, asphalt impregnated, roofing ply. Applied in hot asphalt. Type IV M 39.4" x 164.5' ASTM D2178 Fiberglass reinforced, asphalt impregnated, (1 m x 50.4 m) roofing ply. Applied in hot asphalt. Type VI M 39.4" x 164.5' ASTM D2178 Fiberglass reinforced, asphalt impregnated, (1 in x 50.1 m) roofing ply. Applied in hot asphalt i i I L . . . %: ....... . ........ . ... ... .. . .... •• • . . • • • • • IJOA Vb.: 08- 0118.07 Expiration Date: 03/08/11 Muahi�apeCOtmn Approval Date: 07/10/08 ':' : : : : ':' Page 3 of 30 • • : •0 . . . . . •• .. . . . •• •• 000 0 , APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) ACFoam H Isocyanurate Insulation Atlas Roofing Corp. ISO 95 +, ISO 95+ GL, 95+ GW Isocyanurate Insulation Firestone ISO 95± Composite Isocyanurate Insulation with perlite facer Firestone Fiber Top Regular wood fiber insulation Firestone Rhoflex Composite Polyisocyanurate foam / perlite insulation Firestone Dens Deck Silicon treated gypsum G -P Products ENRGY 3, ENRGY PSI -25, Isocyanurate Insulation Johns Manville UltraGard Gold 11, UltraGard H Fesco Foam Isocyanurate Insulation with perlite facer Johns Manville High Density Wood Fiberboard High Density Wood Fiber insulation Generic board. Perlite Insulation Board Perlite Insulation Generic Iso -Lite E Polyisocyanumte foam insulation International Permalite Multi -Max FA Isocyanurate Insulation Rmax, Inc. C f i i • •• r . • • ••• • s • • • • • • • • • • • • • • • • • • • V r1041o.: 08- 0118.07 rnanaoscot�rrY Expiration Date: 03/08/11 Approval Date: 07/10/08 .� •;• + ; •:• : Page 4of 30 ... . 0 0 ... . . 1 1 . I i I( APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Firestone All - Purpose Insulation and membrane Various Firestone Fastener fastener .2. Firestone HD Fastener Insulation and membrane Various Firestone fastener 3. MB Barbed Metal Metal plates used for 2" dia Firestone Seam Plate membrane securement. 4. Hexagonal Plate Insulation attachment 3j /8" x 2- Firestone hexagonal plate 1 / 8 " 5. Seam Plate Membrane seam attachment 2- dia Firestone plate. 6. Metal Plate Membrane attachment plate. 2" dia Firestone 7. Dekfast Fasteners Insulation and membrane Various SFS Intec fastener 8. Dekfast Hex Plate Insulation and membrane Various SFS Intec fastener 9. # 12 & # 14 Roofgrip Insulation and membrane Various oMG fastener 10. Metal Plate Galvalume AZ50 stress plate 3 square OMG 3" round I 11. Plastic Plate 3.2" round polyethylene stress 3.2" round OMG plate { 12. Olympic Fasteners Insulation and membrane Various OMG fastener 13. Olympic Standard 3" round Galvalume AZ55 3" round OMG stress plate 14. Olympic Plastic plates for fasteners. 3" round OMG 15. Insul-Fixx Fastener Insulation fastener for use in Various SFS Intec wood, steel and concrete decks 16. Insu1-Fixx S Galvalume AZ55 stress plate 3" round SFS Intec 17. Insul -Fixx PG Polyethylene stress plate 3" round SFS Intec 18. Tru -Fast Fasteners Insulation and membrane Various The Tru -Fast Corp. fastener 19. Tru -Fast MP -3 3.23" round Galvalume A.440 • • �.?3 ;roypd • • Th ru -Fast Corp. steel plate • • • • • • 20. Tru -Fast Plastic Plate 3" round polyethylene stress ': T' found: ;' Abe lru -Fast Corp. plate •. ... .. •• • • •.• ••s ••• • • • • • • • • • • • • • • • • •• •• •• • • NOA No.: 08- 0118.07 Expiration Date: 03/08/11 .,tpprovvj Date: 07/10/08 i i i i• i i i i Page 5 of 30 EVIDENCE SUBNIITTED: Test Agency Test Identifier Description Date Factory Mutual Research Corp. 1D5A8.AM FM 4470 09/09/98 3003597 FM 4470 07/14/99 3004786 FM 4470 05/16/00 3005030 FM 4470 08/08/00 3007328 FM 4470 07/12/02 Trinity ( ERD 4810.01.96 -1 PA 114(C) & PA 114(D) 01/31196 4810.10.96 -1 PA 114(J) 10/31/96 F10370.05.08 ASTM C 1289 05/08108 Atlantic & Caribbean Roof ACRC 03 -001 TAS 114 03/06/03 Consulting, LLC. ACRC 03 -007 TAS 114 05/01/03 PRI Asphalt Technologies FBP - 018 -02 -01 ASTM D 6163 09/07/04 FBP -011 -02-01 ASTM D 6164 09/02/04 FBP- 008 -02 -01 ASTM D 6222 09/10/04 FBP - 009 -02 -01 ASTM D 6222 08/31/04 FBP- 010 -02 -01 ASTM D 6164 09/04/04 FBP - 014 -02 -01 ASTM D 6164 09/02/04 FBP -0 15 -02 -01 ASTM D 6509 09/02/04 FBP - 016 -02 -01 ASTM D 6509 09/02/04 FBP- 017 -02 -01 ASTM D 6163 09/13/04 FBP - 019 -02 -01 ASTM D 4601 09/14/04 FBP- 023 -02 -01 ASTM D 6223 09/01/04 FBP - 007 -02 -01 ASTM D 6222 09/14/04 FBP- 020 -02 -01 ASTM D 2178 09/14/04 t i i i • • • • • • . • I MA 1V'o.: 08- 0118.07 Expiration Date: 03/08/11 MIAMI•DADE COUNIY •. • • • • . •. i g prova I Date: 07/10/08 IAPPROVEDIJ • • • • Page 6 of 30 • • • • • • • ..• I • •• •• 0 • •• •• Membrane Type: APP Deck Type 11: Wood, Non - insulated Deck Description: 19/32" or greater plywood or wood plank fasten to supports with #8 x 1 -5/8" wood screws at a maximum spacing of 6" o.c. System Type E(3): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Firestone MB Base or MB Base M mechanically fastened to the wood deck as described below: Fastening #1: Base sheet shall be Iapped 4" and fastened with Firestone #14 AP fasteners 3" ' Round Metal Plates 12" o.c. in the lap and two rows staggered in the center of the sheet 12" o.c. Fasten' 2: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 6" o.c. at the lap and two rows staggered in the center of the sheet 6" o.c. Ply Sheet: (Optional) One or more plies of Firestone MB. Base Sheet, Type IV, Type IV M, Type VI or Type VI M ply sheet or other listed base sheet applied in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 ibsJsq.; or one ply Firestone APP 160 or APP 170 torch applied Membrane: One ply of APP 160, APP 170, APP 180 or APP 180 FR torch applied parallel to the base ply, with overlaps staggered 12 ". i Surfacing: (Optional) Install one of the following. 1. Gravel or slag at 400 lb. and 3001b., respectively, set in a flood coat of type .III or IV asphalt at 60 lbJsq.. 2. Karnak No. 97, No. 97 AF or No. 169 at an application rate of I %2 galJsq.. 3. Fields F900 emulsion, Gilsonite Durakote # 151, Gibson Homans #6192 -900 applied at 6 gal.Jsq. with 60 lbs. of roofing granules set in the wet coating. 4. Owens Corning Fiberglass Cap sheet GAF Mineral Surface Capsheet or Manville Glaskap in a full mopping of approved asphalt applied within the ' EVT range and at a rate of 2040 lbs. /sq.. Maximum Design Pressure: —52.5 psf (See General Limitation #7) ....... . .. .. • .... ••• .. ... .. . .... • • • • • • • • • • *00 • • • Soo :' NSA NV. 08- 0118.07 Expiration Date: 03/08/11 I APPROVED c Approval Date: 07/10/08 •;' ; ; ; ; ';' ; : Page 28 of 30 ♦ t f WOOD DECK SYSTEM LDnTATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIlVIITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EW range and at a rate of 20- 401bsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every IT in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 Ibf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant. (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e, perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance AWMadofd4ft Britt tUfflorida Building Code and Rule 911-72 of the Florida Administrative Code. .:.': .: '.. END OF THIS ACCEPTANCE" • ' •• • • • • • • • • • •• • • • • • • • •• •• NOA No.: 08- 0118.07 M�AM�z�4DE CouwT�r • • • • • Expiration Date: 03/08/11 � • A�prov * .. l Date: 07/10/08 • . • Page 30 of 30 • •..... . . ... . . . ... . . M IA:M HD MIAMI -DADS COUNTY, FLORIDA _ MEIRO -DADS FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE (NOA) Firestone Building Products Company 310 East 96 Street Indianapolis, IN 46240 -3702 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AFU (in than Miami Dade County) reserve the right to have this product or material tested for q ity '' ce purposes. If this product or perform in the material fails to accepted he A uf�r `` ur the expense of such testing pted manner, and the AHJ may immediately revoke, modify r s $tithe of product or material within their jurisdiction. BORA reserves the rightroke > s acepce, if it is determined by Miami -Dade County Product Control Division that this pro4uc or fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building i Code, including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Firestone Modified Bitumen Self Adhered Roof Systems over Recover Decks I LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site4 t$g request 0 Builc g Official. This NOA Supercedes NOA No. 08- 0118.03 and consists of pages I; h=ow li. ; •; • • • The submitted documentation was reviewed by Jorge L. Acebb. 0"', • • • • • • • • • •• • • • • • • PtOA No.: 08- 0716.03 Expiration Date: 06/26113 MI atn►aE eouwrr rov Date. 08/21/08 ;.; : ; Page 1 of 12 ... . . . .•. . 0 . i i ROOFING SYSTEM APPROVAL Categarv: Roofing Sub - Category_ Modified Bitumen Material: APP /SBS Deck Type: Recover Maximum Design Pressure See Specific Deck Types TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description APP 180 39.4" x 32'10" ASTM D 5147 Polyester reinforced modified bitumen, granule surfaced membrane. Torch applied. APP 180 FR 39.4"x32'10" ASTM D 5147 Polyester reinforced, fire regardant modified bitumen, granule surfaced membrane. Torch applied. APP 170 39.4" x 33'6" ASTM D 5147 Polyester reinforced modified bitumen membrane. Torch applied. APP 160 39.4"x32'10" ASTM D 5147 Polyester reinforced modified bitumen membrane. Torch plied 'M' MB Base SA Base Sheet 36" x 108' ASTM D 5147 Fiberglass re' rase sheet, asphalt coat n sides wrlh a ` astie release f. A ` ►e d�ders de p � " SBS Premium FR Torch 39.4"x33'10" ASTM D 6164 ire rated, modeJbitum membrane with a burn - off film'and reinforced with non -woven i polyester mat. j Rhoflex FR Granule ASTM D6223 Glass/Polyester reinforced modified bitumen cap sheet APPROVED NsuLATIONS: TABLE 2 Product Name Product Description Manufacturer j (With Current NOA) ISO 95+ GL Isocyanurate Insulation Firestone Dens Deck Prime Silicon treated gypsum G -P Products Securock Fiber Reinforced Coverboard US Gypsum t • • • • • • • • • • • • • • • • •• •• •• i • • NOAgNo.:08- 0716.03 ►aa coil, Expiration Date: 06!26/13 j . • • • • ,,Approval Date: 08/21/08 •; Page 2 of 12 . .. .. . . . .. .. APPRovED F ASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Firestone All- Purpose Insulation and membrane Various Firestone Fastener # 15 fastener 2. Firestone HD Fastener Insulation and membrane Various Firestone #15 fastener 3. Firestone Concrete 1 /4" diameter concrete deck Various Firestone Drives fastener. 4. MB Barbed Metal Metal plates used for 2" dia Firestone Seam Plate membrane securement. 5. Hexagonal Plate insulation attachment 3 3 /8" x 2- Firestone hexagonal plate 1 /8" 6. Seam Plate Membrane seam attachment 2- dia Firestone plate. 7. Metal Plate Membrane attachment plate. 2" dia Firestone 8. Polymer Fastener Glass reinforced nylon fastener 11 /6" dia Firestone for Gypsum or CWF decks 9. Polymer Plate Galvalumeplate for use with 3" square Firestone the Polymer Fastener 10. Insulation Fastening Insulation plate for use with 3" round restone j Plate Firestone Fasteners s E Bm EVIDENC Su n=D: 6 FY' ?,. Test ALYencv Test IdentifierDescriation Date i Factory Mutual Research Corp. 3022492 FM 4470 01/17105 3028093 FM 4470 10/26/07 3020395 FM 4470 11/29/04 3014537 FM 4470 11/29/04 3012321 FM 4470 07/29/02 3015692 FM 4470 08/05/03 Trinity I ERD F7370.11.07 FM 4470 / TAS 114 11/22107 F8800A1.08 -R1 ASTM D903 /TAS 114 01/17/08 F10370.05.08 ASTM C 1289 05/08/08 PRI Asphalt Technologies FBP- 011 -02 -01 ..... ,ASXM•D 6,16*4 .. 09/02/04 FBP- 008 -02 -01 1; 09/10/04 FBP- 009 -02 -01 • ; �,�5 M l� �2 • • • 08/31/04 FBP - 015 -02-01 ASTM D 6509 09/02/04 FBP -023 -02 -01 ASTMD 6223 09/01/04 { FBP- 007 -02 -01 . • • •' • A&T= 622% O V 09/14/04 i • NOA No.: 08- 0716.03 f Expiration Date: 06!26/13 a� 0VE rov .. ,. � .... ..... Alsp 1 Date: 08/21/08 p Page 3 of 12 1 i Membrane Type: SBS Deck Type 71: Recover, Insulated Deck Description: Concrete System Type A(4): One or more layers of insulation adhered with approved adhesive to existing BUR; membrane torch applied. All General and System Limitations apply. One or more layers of the following insulations: Base Insulation Layer Insulation Fasteners Fastener ISO 95+ GL (Table 3) Density /fe Minimum 1.5" thick N/A N/A Note: Insulation shall be adhered to the existing deck with Tite -Set Insulation Adhesive in 3-3YP ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners Fastener Secnrock (Table 3) Density /fi Minimum 1/" thick N/A N/A Note: Top insulation layer shall be adhered in full mopping of approved asphalt within the EW range and at a rate of 25 lbs/100 ft or with OlyBond at a rate of 1 gal/sq. or Insta -Stik, OlyBoud 500, Firestone I.S.O. FIX H, Firestone I.S.O. Twin Pack or Polyfoam Tite -Set in ribbons 12" o c. Please refer to Roofing Application Standard RAS 117 for insulation attachment Note: Securock shall be primed with ASTM D41 asphalt primer and allowed to dry prior to j application of base sheet. Base Sheet: One or more plies of Firestone MB Base SA base sh if ti e d t insulation. , a� Membrane: One ply of Firestone SBS Premium` FR Torc h apgliec e Surfacing (Optional) Install one of the following to o requ classification. 1. Gravel or slag at 400 lbs/sq or 3001bs/sq, respectively, in a flood coat of approved asphalt at 60 lbs/sq. 2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at B6 gal/sq. 3. Kokem Products Sunguard Acrylic Roof Coating at 1 gal/sq. 4. Monsey Endure Aluminum Roof Coating, Weather Check or Pro -Grade Aluminum Roof Coating at 1'h gal/sq. 5. Grundy al MB Aluminum Roof Coating at 1 -2 gal/sq. 6. Fields F350 Heat Shield Aluminum Coating or F630 Heat Shield Fibered Aluminum Coating at I YZ gal/sq. Maximum Design • • • • • • • Pressure: -262.5 psf (See General Limitation #9; • • • • . • •' • : • ' N4A Nj,; 08- 0716.03 MIAMI�QADECGUNTY • • • • Expirdtion Date: 06/26113 "' • Approval Date: 08/21/08 •�• .�. Page 7of 12 I i r RECOVER SYSTEM LIMIT ATIONS: I. All System Limitations and General Limitations shall apply. See specific deck type Notice of Acceptance for deck type System Limitations. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 IbsJsq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a I minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the i Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastene^r,acing shall utilize the withdrawal resistance value taken from Testing Application StandarTA�0:?and j calculations in compliance with Roofing Application Standard RAS 113* � 7. Perimeter and corner areas shall comply with the enhanced uplift s e u eht� of 140 areas. Fastener densities shall be increased for both insulation and base sh tjirl in, nce with Roofing Application Standard RAS 117. Calculations prepared,i ` ed Baled by a Florida registered Professional Engineer, Registered Architect, or Registoof Consultant (When this limitation is specifically referred within this NOA, General Limitati on #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this N%A euesaIjAmitatWu #7 vW not be applicable.) . . . ...... . 10 All products listed herein shall have a quality assurance giqdit Jul jcegjIA; a 49 the Florida Building i Code and Rule 9B -72 of the Florida Administrative Code. i END OF THIS ACCERTANCE. ...... I % •• .• • • • • a• 440A &o.: 08- 0716.03 Expiration Date: 06/26/13 M o� tlpprov al Date: 08/21/08 • • • • Page 12 of 12 I 4 � v t t f � . .. .. . . . .. .. . . . . . . . . . . • • • . • • • • • • • • • • • •• • • • • ••• • 0 •• ••• • • • • • •• 4 � v t t f � M I A M 1•DAIE MTANII -DARE COUNTY, FLORIDA _ METRO -DARE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WFS'T FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE (NOA) Owens Corning One Owens Corning Parkway Toledo, OH 43659 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. H this product or material fails to perform ' accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediatel voke, odify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the ri t to rev ok this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements o the ap 'cable building code. This product is approved as described erein, and been de i to comply with the Florida Building Code, including the High Velocity Hurricane ne. DESCRIPTION: Oakridge PRO 40 i LABELING: Each unit shall bear a p e 1 with the manufacturer's name or logo, city, state and E following statement: "Miami -Dade oun Pro Con 1 ppr unfQs ot.Rk se noted herein. 4 RENEWAL of this NOA shall be ca i after a ren " apps atign h# bee -and there has been no change in the applicable building code eg 'vely aff a x cd duct. TERMINATION of this NOA will occ the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any Product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA #04- 1124.01 and consists of4ages j 6r b*4 : • The submitted documentation was reviewed by Alex Tigers 0 00 .. . . ••• ••• ... • • • • • rbA 1G.: 05- 1213.02 • • • • • • • • ; Expi r4Uon hate: 07/19/11 Approval Date: 04127/06 • i • i i r i • i • i i Pap Iof4 I s t r ROOFING ASSEMBLY APPROVAL Cates Roofing Sub - Category: 07310 Asphalt Shingles Materials Laminate Deck Tyue: 'Wood 1. SCOPE This revises a roofing system using Owens Corning Oakridge PRO 40 AR. Asphalt shingles manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance. 2. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Oakridge PRO 40 AR 13 x 39'Is" TAS 110 A heavy weight, fiberglass reinforced four tab asphalt shingle. Accessory Shingles various proprietary Accessory shingles for hip, ridge and starter strip applications. 3. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Celotex Corp. Testing Service 258495B TAS 100 06/01/98 PRI Asphalt Technologies, Inc. OCF-069 -02 -01 TAS 100 08/21/03 OCF- 071 -02 -01 TAS 100 08!22103 OCF- 075 -02 -01 TAS 100 03/01/04 OCF -083 -02-01 q � 7 , TAS100 09/24/04 Underwriters Laboratories, Inc. 94NK9632r7� T AS ? 07 ' 07101!98 03NK04954 TAS .07 03/28/03 j 03NK04954 TAS 07 & 03/11/03 03NK21814 TAS 107 08/28/03 04NK06517 TAS 107 05/04104 03NK33481 TAS 107 12/02/03 96NK30503 ASTM E 108 .10/11/96 98NK16342 ASTM D 3462 05/14/98 98NK24243 ASTM D 3462 09/03/98 OONK14644 ASTM D 3462 01/29/01 02NK02878 ASTM D 3462 10/15/03 02NK02878 ASTM D 3462 10/20/03 98NK38907 ASTM D 3462 12/14/98 4. LEMIITATIONS 0 00 • • • • • • } 4.1 Fire classification is not part of this acceptaAsev rAr 4 o a x; Approved Roofing Materials Directory for fire ratings of this product.• so* • • • • • f 4.2 Shall not be installed on roof mean heights in excess of 33 ft. 4.3 All products listed herein shall have a quality assurance audit in.acicordanw with the Florida j Building Code and Rule 9B -72 of the Florida U,dmi Aratiwe G ••• ••• • ••• �• JOAAe.:05. 1213.02 j Expiration Date: 07/19/11 Approval Date: 04/27/06 ••• • • • ••• • Pap 2of4 • •• •• • • • •• f• ` ••• • • w ••• • • , 5. INSTALLATION 5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115 5.3 The manufacturer shall provide clearly written application instructions. 5.4 Exposure and course layout shall be in compliance with Detail W, attached. 5.5 Nailing shall be in compliance with Detail W, attached 6. LABELING 6.1 Shingles shall be labeled with the Miami -Dade Logo or the wording "Miami -Dade County Product Control Approved". 7. BUILDING PERMIT REQUIREMENTS 7.1 Application for building permit shall be accompanied by copies of the following: 7.1.1 This Notice of Acceptance. 7.1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. 8. MANUFACTURING PLANTS 8.1 Savannah, GA 8.2 Medina, OH 83 Jacksonville, FL 8.4 Houston, TX 8.5 Irving, TX 8.6 Denver, CO. 8.7 Portland, OR. I I i i o y • • • • • • : : « 1UA if*.: 05- 1213.02 Expirationbate: o7n9n1 Approval Date: 04!27106 ••• • • • • ••• • • Page 3of4 1 DETAm A GE OF ROOF OWENS CORNING OAKRIDGE PRO 40 AR !3" THIRD COURSE SECOND COURSE ------- rA M rA rA FIRST COURSE DETAIL B 39 3/8" 4 13 -114" 1 6 g " ,r 518" EXPOSURE END OF THIS ACCEPTANCE ...... • . . • .. . . • • .. • %: . .. •.. •. . .... i • 'i i • i • • • • ` • • i • • @ is.: 05- 1213.02 j a L - Expiration Date: 07/19/11 Approval Date: 0412'1!06 Paw4of4 • •• •• • • A. •• •• I • ..• • • . • •• • • • • •. .. . TFWZ.R2453 - Prepared Roof - covering Materials http: / /database.ul.comlegi- bin /XYV /tomplate/LISEXT /1FRAME /show... UL ONLINE CERTIFICATIONS DIRECTORY TFWZ. R2453 Prepared Roof- covering Materials Pace Bottom Prepared Roof- covering Materials See General Information for Prepared Roof - covering Materials OWENS CORDING 82453 1 OWENS CORNING PKY TOLEDO, OH 43659 USA Asphalt glass fiber mat sheet roofing designated "Mineral Surfaced Roll Roofing ", for installation as Class C prepared roof coverings. These rolls may also bear the statement, "Also Classified in accordance with ASTM D3909. Asphalt glass fiber mat and shingles designated Berkshire, Classic, Supreme, Oakridge (Oakridge Pro 30), Oakridge Pro 40, Oakridge Pro 50, Woodcrest, Woodmoor, Prominence, WeatherGuard HP, Duration, Duration Premium, Skyview and Starter strip (Supreme), for installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks with underlayment such as asphalt saturated felt or shingle underlayment classified by UL as a prepared roofing accessory ( underlayment not required for hip and ridge shingles) and on minimum 15/32 in. thick plywood decks without underlayment. Asphalt glass fiber mat shingles, for installation as Class C prepared roof coverings on minimum 3/8 in. thick plywood decks without underlayment. Asphalt glass fiber mat and hip and ridge shingles for installation as wind resistant roof coverings. These shingles may also bear the statement "Also Classified in accordance with ASTM D3161, Class F ", "Also Classified in accordance with ASTM D3462" and "Also Classified in accordance with CSA -A 123.5 ". These roofing systems may Incorporate starter shingles designated "Strip Shingle" or "TRI- BUILT Shingle Starter'. Hip and ridge shingles designated "High Ridge ", "WeatherGuard HP ", "Berkshire", "Hip & Ridge shingles with sealant" for Installation as Class A prepared roof coverings. These shingles may also bear the statements, "Also Classified in accordance with ASTM D3161, Class F ", "Also Classified In accordance with ASTM D3462" and the Hip & Ridge with sealant shingle may bear the statement "Also Classified in accordance with CSA -A 123.5 ". Hip and ridge shingles designated "Deco Ridge ", for installation as Class A prepared roof coverings. Suitable for Installation on minimum 3/8 in. thick plywood decks and on minimum 15/32 in. thick plywood decks without undertayment. Also Classified in accordance with ASTM D3161, Class A or Class F. Last Updated on 2009 -09 -24 Questions? Notice of Disclaimer Page Top Copyright Cc) 2009 Underwriters Laboratories Inc .@ The appearance of a company's name or product in this database does not In Itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be consklered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must Include a copyright notice in the following format: "Copyright 2009 Underwriters Laboratories Inc. @" An independent organization working for a safer world with integrity, precision and knowledge. Ifil 1 7A , • ••• • • • • • •• • • • • • • • • • •• • • • • ••• • •• ••• •• • • • •• •• • • ••• ••• ••• • • • • • • • • • • • • • • • • • •• •• • • • • • • • ••• • • • • ••• • • 1 of 1 .:0 . . • • • • 0 0 0 ... . • • • • • 11/18/2009 9:39 AM . TGFU R9516 - Roofing System http:Hdatabase.ul.com/cgi- bin /XYV /template/LISEX`T/1FRAME/show... t ONLINE CERTIFICATIONS nIRECTDRY TGFU.R9516 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems FIRESTONE BUILDING PRODUCTS CO L L C R9516 250 W 96TH ST INDIANAPOLIS, IN 46260 USA References to Type G1 and Type G2 ply and base sheets Include "Type IV ", "Type VP' (Type G1), "Ply IV (4) Mn (Type G1), "Ply VI (6) Mn (Type GI), "MB Base Sheet M" (Type G2), "MB Base Sheet" (Type G2) in any of the following Classifications. "Firestone Venting Base Sheet" (Type G3) may be used in lieu of any Type G2 base in any applicable non - combustible Classification. "SBS Poly Base Sheet" can be used In any non- combustible deck system which utilizes a Firestone SBS cap sheet. "ISOGARD" and "150 300" are acceptable alternates to "ISO 95 +" In any applicable Classification. "IS.O.FD( Adhesive" may be used in any of the following Classifications to adhere insulation to the roof deck. "IS.O. Spray' S" may be used in any of the fotlowing Classifications to adhere Insulation to both non - combustible roof deck substrates and other Insulation layers including wood fiberboard and G -P Gypsum Corp. "Dens -Deck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuarc" Roofboard." "Tapered ISO 95 +CAN" may be substituted for "ISO 95 +CAN" In any of the systems listed below. "ISO 95 +CAN" may be perforated on one side for use as the contact side for BUR or modified bitumen membrane. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Class A 1. Deck: NC IncQrte: 3 Insulation: — "LSO 95 +FK", "GO, "GW" or "Rhofiex Isocyanurate FK", "GO, "GW ", any thickness, mechanically fastened or adhered with hot mopping asphalt. Ply Sheet: — Two to four layers Type 15, G1 or G2, any combination. Surfacing: — Gravel. 2. Dedk NC Incline: 3 Insulation: — "ISO 95 +Composite ", "Rhoflex Isocyanurate Composite" or "ISO 95 +Wood Fiberboard Composite ", mechanically fastened or adhered with hot mopping asphalt, 1.5 to 3.5 in. thick. Insulation (Optional): — Perilte, I in. thick. Ply Sheet: — Three to four layers Type 15, GI or G2, any combination. Surfacing: — Gravel, slag or crushed stone. 3. Deck. NC Incline: 3 Base Sheet: — "MB Base Sheet", mechanically fastened or hot mopped. Insulation (Optional): — Any UL Classified (EPS must be covered with 1/2 in. thick min glass fiber, wood fiber or perlite), any thickness, mechanically fastened or hot mopped. Ply Sheet: — One or more layers " MB Base Sheet " or Type G1, any combination. Surfacing: — Gravel, crushed stone or crushed slag, In a flood coat of hot roofing asphalt. 4. Deck C -15/32 Incline: 1 • • • • i s i • • • i i • • Insulation O tiona y • • • • • • • • • • • ( p �: —any UL Classified an thickness. • • • • • • • • • Ply Sheet: — One or more plies Type G1, G2 or "SBS Base Sheet ", meftnicall %stgrted o*r hod' Appd, any combination. Membrane: — "SBS Smooth ", "SBS Premium" or "SBS" (modified bitumen), hot mopped. Surfacing. — Gravel, crushed stone or crushed slag, In a flood coat of asphalt. •• • • ••• ••• ••• 5. Dedk NC Incline: 1 - 1/2 i• i i i i i • • • • • • • • • • • • • • • • •• •• •• Insulation (Optional): — any UL Classified, any thickness. • • • • • • Ply Sheet: — One or more plies Type G1, G2 or "SBS Base Sheet ", mechanically fastened or hot mopped, any combination. ••• • • • • ••• • • • • • • • • • • • • 1 of 43 • • • • • . • • • • 11/18/2009 9:56 AM ... . •.. . . TGFU R9516 - Roofing Systems bttp: / /database.ul.com/cgi- bin/ XYV /tomplate/LISEX`T /IFRAMEtshow... 17. Deck: NC Incline: 2 Insulation: — One or more layers "ISO 95 +CAN ", any thickness, loose laid or mechanically fastened. Slipsheet (Optimal). — One ply "FR -30 ", "FR -11" or "FR400" loose laid or mechanically fastened. Membrane: — Any membrane Classified for use in a ballasted system. 18. Deck: C 15/32 Incline: 2 Insulation: — "ISO 95 +CAN ", 2 in. max, secured with mechanical fasteners, hot mopped or adhered with any cold application adhesive Classified under Roof Deck Construction Materials. Base Sheet (Optional): — Owens- Coming Fiberglas "Perma Ply R ", "Perma Ply 1V", "Perma Ply 28 ", "Roll Roofing No. 45" or Type 15 asphalt organic felt, mechanically fastened or hot mopped. Membrane: — Performance Roof Systems "Derbigum" (modified bitumen), heat fused. Surfacing: — Gravel or slag in hot roofing asphalt. 19. Deck: C 15/32 Incline: 3 Insulation: — "]SO 95 +CAN ", 1 -1/2 in. max, secured with mechanical fasteners, hot roofing asphalt or any cold application adhesive Classified under Roof Deck Construction Materials. Base Sheet (Optional): — Owens - Coming Fiberglas "Perma Ply R ", "Perma Ply 1V", "Perma Ply 28 ", "Roll Roofing No. 45" or Type 15 asphalt organic felt, mechanically fastened or hot mopped. Membrane: — Performance Roof Systems "Derbigum" (modified bitumen), heat fused. Surfacing: — Gravel or slag in hot roofing asphalt. 20. Deck: NC Incline: 3 Insulation: — "LSO 95 +CAN ", 1 -1/2 in. max, mechanically fastened or adhered with hot roofing asphalt or any cold application adhesive Classified under Roof Deck Construction Materials. Base Sheet (Optional): — Owens- Coming Fiberglas "Perma Ply R ", "Perma Ply N ", "Perma Ply 28 ", "Roll Roofing No. 45" or Type 15 asphalt organic felt, mechanically fastened or adhered with hot roofing asphalt. Membrane: — Performance Roof Systems "Derbigum" (modified bitumen), heat fused. Surfacing: — Owens - Coming Fiberglas "20 F asphalt emulsion" at 2 gal/sq. and No. 11 roofing granules, 50 lb/sq. Surface is allowed to weather 30 -60 days before emulsion application. 21. Deck. C 15/32 Incline. 1/2 Insulation: — "ISO 95 +CAN ", 1 -1/2 In. max, mechanically fastened or adhered with hot roofing asphalt. Base Sheet (Optional): — Owens- Coming Fiberglas "Perma Ply R ", "Perma Ply 1V", "Perma Ply 28 ", "Roll Roofing No. 45" or Type 15 asphalt organic felt, mechanically fastened or adhered with hot roofing asphalt. Membrane: — Performance Roof Systems "Derbigum" (modified bitumen), heat fused. Surfacing: — Owens - Coming Fiberglas "20 F asphalt emulsion" at 2 gall /sq. and No. 11 roofing granules, 50 lb/sq. The surface is allowed to weather 30 -60 days before emulsion application. 22. Deck NC Incline: 3 Membrane: — Any UL CLassiffed PVC, EPDM, CPE, CSPE, TRE, nitrile alloy or modified bitumen, loose laid or mechanically fastened. Insulation: — "LSO 95 +CAN ". Surfacing: — River bottom stone (3/4 to 1 -3/4 in. diam. ) 1000 lb/sq. Class A - FuOy Adhered The Insulation may be mechanically fastened to the deck with screws and metal or plastic discs, hot roofing asphalt or a combination of screws /discs and hot roofing asphalt. As an alternate In all assemblies except those Incorporating "Fire Retardant (FR) RubberGard" or EPS, a layer of 1/2 In. thick gypsum board may be placed between the insulation and the roof deck to establish a combustible deck (15/32) Classification. The membrane Is adhered to the Insulation with "BA -2004 Bonding Adhesive ", "Royal BA2004T", or "Single -Ply LVOC Bonding Adhesive ", "Single -Ply LVOC Bonding Adhesive - 1168" or "Single -Ply LVOC Flashing Adhesive - 1168 ", "UltraPly 13736 LVOC ", "Water Based Bonding Adhesive ", "Firestone Water Based Bonding Adhesive S" or "Triumph Bonding Adhesive" applied to the insulation and to the membrane at 1 -2/3 gal /sq total, except the "Water Based Bonding Adhesive" which Is applied at 1 gal/125 sq ft total and "Firestone Water Based Bonding Adhesive S" which is applied at 1 gal/120 sq it total. The lap splices are sealed with "SA 1065 Splicing Adhesive ", "SA -1065 Splice Adhesive Plus" or "Triumph Splice Adhesive" applied at approximately 150 to 175 lin ft per gal (3 in. lap coated both mating surfaces) or approximately 130 to 150 lin ft per gal (4 In. lap coated both mating surfaces). The laps may also be sealed with "QuickSeam Splice Tape" (510/9/92A) or "Triumph Seam Tape ". The edges of the laps are sealed with a 3/8 in. by 1/4 in. bead of "LS- 3029A1 Lap Sealant ", "Lap Sealant HS" or "Triumph Lap Sealant" (use of lap sealant with splice tapes is optional). The lap splices of the EPDM membranes may be sealed with "Quickseam Splice Tape ST 510/9/92A" then covered with "5 in. QuickSeam Flashing ". Only Triumph Accessory Products are acceptable for use with Triumph EPDM membranes. Firestone "QuickPrime Plus LVOC ", "QuickPrime" or "QulckPrime Plus" and "Royal CW3g51 rpoiing piimeg rgpy bgjmd with any Classified Firestone EPDM membrane assembly to prepare the seam area to receive any QwickSeampr•duet or SA - 4085 Splice Adhesive and maintain the rating for that assembly. • • • • • • • • • • •• • • • • ••• • "RubberGard 90 ", is an acceptable alternate to "Standard RubberGard" (45 or 60"11) "arty syMm Acoroor'atirlc'the latter at Incliner not exceeding 1/2 In. Unless otherwise indicated, the EPDM may be surfaced with "PC -100 coating" at 1 galAsq with the op*m of applying eral purpose or silica sand (sieve size 50 to 100) into the wet coating at 35 lb/sq. Membrane should weld er appr)xim4el� 2 *eks prkt to agpl cation of the "PC -100" coating. • • • • • • • • • • • • • • • • % •• % Karnak No. 81 modified bitumen adhesive may be used as an alternate method'of attachment for the modified bitumen membranes in the following ballasted or heat fused systems. An additional ply of "Firestone APP 140 ", "APP 160 ", "APP 170" or "Monoply Plus" may be used In any 7of43 �;• ;• •; ••• •;• ;• '; 11/18/20099:57 AM TGFU R9516 - Roofing Systems bttp: / /database.ul.comtcgi- bin/ XYV /teiMlate/LJSEX`T/1FRAME/show... , APP modified bitumen Firestone "MB Base Sheet ", "MB Base Sheet M ", "APP 80 Glass Base ", "SBS Glass Torch Base ", Malarkey "Premium I SBS Modified Base Sheet No. S01" and Yntec /Permaglas "Ultra Base" are acceptable substitutes and may be used in any assembly which utilizes Type G1, Type G2, Johns Manville "No. 28 Glasbase ", Bird "CRS" base sheet or GAF "GAF -Glas Base Sheets ". "MB Base SA" may be used In any modified bitumen roofing system as an optional additional base sheet. "Nall Base" insulation Is an acceptable alternate to all Insulations except gypsum wallboard or G -P Gypsum DensDeck ®) In the following Classifications. "Fire Retardant Reinforced" EPDM membrane is an acceptable alternate to "FR RubberGard ", "Standard RubberGard " "RubberGard MAX FR" and "Standard Reinforced RubberGard" in all applicable Classifications. "Standard Reinforced RubberGard" or "RubberGard MAX FR" EPDM membrane Is an acceptable alternate to "Standard RubberGard" in all applicable Classifications. Unless otherwise indicated, insulation and base sheets may be mechanically attached, hot mopped or attached with cold application adhesive as Listed under Adhesives, Roof Construction Materials, in any system incorporating modified bitumen. "APP 140" and "APP 180" are acceptable alternates to "APP 160" or "APP 170" in all applicable systems. The following membranes are equivalent: A.) "SBS Premium FW, "SBS Premium FR Torch Grade ", "SBS FR ". B.) "SBS ", "SBS Torch Grade ". C.) "SBS Premium ", "SBS Premium Torch Grade ". D.) "SBS Smooth ", "SBS Smooth Torch Grade ". E.) "SBS Glass ", "SBS Glass Torch Grade ". F.) "SBS Glass FR", "SBS Glass FR Torch Grade ". "SBS Glass" is an acceptable alternate to "SBS ", "SBS Smooth" and "SBS Premium" In all applicable systems. "SBS Smooth" / "SBS Smooth Torch Grade" membrane may be used In any noncombustible system utilizing the above "SBS" membranes as an alternate to Type G1 or G2 base /ply sheets, provided the substitution occurs directly over wood fiber, glass fiber or perirte insulation only. The "SBS Smooth" / "SBS Smooth Torch Grade" membranes may be utilized in more than one layer. "SBS Premium Base Sheet" may be used in lieu of "SBS Base Sheet" in any system Incorporating the latter. "SBS Poly Torch Base Sheet" may be added to any applicable classified system without adversely affecting the existing Classification. It may also be used as a substitute for any base sheet In non - combustible deck roofing systems. (Optional) Noncombustible deck Classifications ( "FR RubberGard" systems excluded) are applicable for use over combustible (15/32 in. min plywood) decks when 1/2 in. (min) gypsum board or 1/4 in. (min) G -P Gypsum. DensDeck® are used directly over the deck with all joints staggered 6 In. (min) from plywood joints. "Standard RubberGard Fleece - Backed" (EPDM) membrane, adhered with Insul Foam "Roof -Bond RB -100 Adhesive" at a thickness of 3/8 in., is an acceptable alternate to "Standard RubberGard" In all of the applicable fully adhered systems below. Firestone "Ply IV ", "Ply Vr, "Ply IV (4) M" or Ply VI (6) M" are acceptable alternates In all systems where a Type G1 ply sheet Is indicated. "Triumph EPDM", "Triumph Reinforced EPDM ", "Triumph FR", "Triumph LS -FR" are acceptable alternates to Firestone "Standard RubberGard ", Firestone "Standard Reinforced RubberGard ", Firestone "Fire Retardant RubberGard ", Firestone "LS -FR", respectively in all applicable Classifications. Unless otherwise Indicated,. the "UltraPly TPO" and "UltraPly" (TPA) membranes are fully adhered with "UltraPly Bonding Adhesive ", 1 gal/45 sq ft finished application rate or "Water Based Bonding Adhesive" applied at 1 -1/4 gai/sq. Adjacent sheets are lapped 3 to 6 in., laps are heat sealed. Edges of laps may be sealed with 1/4 bead of "WS6 -TPO- 3002 ". "SBS Base Sheet" may be used in lieu of "MB Base Sheet" In all applicable Classifications. "ACRYLIC Base Coat for Asphalt" (1 -1/2 gal/sq) and "PC -100 Coating" (1 gal/sq) may be used over any of the following modified bitumen membranes: "SBS FR ", "SBS FR Torch Grade ", "SBS Premium FR ", "SBS Premium FR Torch Grade ", "SBS Glass FR", "SBS Glass FR Torch Grade ", "APP 180 FR" or "Rho Flex FR." Unless otherwise indicated, the EPDM membranes may be fully adhered with "BA- 2004x, "Single -Ply LVOC Bonding Adhesive- 1168" or "Single -Ply LVOC Flashing Adhesive - 1168" 1 gal /45 sq ft finished application rate. 1. Deck: NC Incline: 1/4 • • • • • • • • • • • • Insulation (Optional): — Any combination of the following may be use:Kgo n1bi ti l�te IQrri�t'i polystyrene (expanded or extruded), perlite, wood fiber, glass fiber. .. • • • • • • • • • • Insulation: — Wood fiber (Huebert), 1 In. thick, or "FiberTop B ", " FiberTop E", "FiberTop C" or "FiberTop S ", 1/2 in. thick min. Membrane: — "Standard RubberGard" (EPDM), 45 or 60 m8. 2. Deck: NC •• • • ••• ••• ••• indine:l • • • • • • • • • • • • • 0 • • • • • Insulation (Optional): — Polylsocyanurate, expanded polystyrene dfextreV poly.V%ne:Jf phenor, ant thickness, any combination. Insulation: — Wood fiber (Huebert), 1 In. thick, or "FiberTop B ", " FlberTop E", "Fiber�rop C" or "FiberTop S ", 1/2 in. thick min. Membrane: — "Standard RubberGard" (EPDM), 4S or 60 mI. ••• • • • • ••• • • • • • • • • • • 8 of 43 : : :.'.: 11/18/2009 10:09 AM ... . . . .•. . . TGFU R9516 - Roofing Systems htip: / /database.ul.com/cgi- bin /XYV /template/LISEXT /1FRAME/show... sealed with Uniroyal "Royal M6365 " adhesive at 1/2 gal /100 sq It and the lap edges are caulked with Uniroyal "Royal M6389 ". 79. Dedc C -15/32 Inane: 1/2 Insulation (Optional): — Periite or glass fiber, 15/16 in. thick min, or polylsocyanurate, 2 in. thick min, joints In Insulation offset 6 In. with joints in deck. Base Sheet: — Two or more plies "MB Base Sheet" (Type G2) or any Type G2 weighing a min of 23 Ibs /sq, mechanically fastened, spot or fully mopped. Ply Sheet (Optional): — "APP 160" or "APP 170" (modified bitumen), heat fused. Membrane: — "APP 180 FR" or "RhoFlex FR" (modified bitumen), heat fused. 80. Dade NC Incline: 1 Insulation: — Polystyrene (1 to 2.5 Ibs /cu /ft), 1 in. min. Slip Sheet: — Atlas Roofing "FR -10 ". Membrane: — "UitraPly" (TPA), 40 -100 mil. 81. Deck: NC Incline: 1 Insulation: — Perite, any thickness. Membrane: —"UltraPly" (TPA), 40 -100 mil. 82. Dedc NC Incline: 1 -1/2 Insulation (Optional): — Polystyrene (tapered or uniform thickness) or Dow Chemical "Styrofoam LG, PD, RM, SM, TG or STYROIB" , any thickness or glass fiber, any thickness. Insulation: — Wood fiber (Huebert) 1 in. or "FiberTop B ", " FiberTop E", "FiberTop C" or "FiberTop S ", 1/2 in. min. Membrane: — "UltraPly" (TPA), 40 -100 mil. 83. Deck: NC Incline: 1 Insulating Concrete: — Deck covered with either of the following insulating concretes (poured in place): cellular, vermiculite, perlite, gypsum or structural. Optionally, a base concrete deck may be used If all exposed surface joints are grouted. Membrane: —"UltraPly" (TPA), 40 -100 mil. 84. Meted 85. e . 6. Deck. 15/32 Incline: 1/2 ulat on (Optional): — Perlite or glass fiber, 15/16 in. thick min, or polyisocyanurate, 2 in. thick min, joints in insulation offset 6 In with joints in deck. Base Sheet: — Two or more plies "MB Base Sheet" (Type G2) or any Type G2 weighing a min of 23 ibs /sq, mechanically fastened, spot or fully mopped. Ply Sheet (Optional): — "APP 160" or "APP 170" (modified bitumen), heat fused. Membrane: — "APP 180 FR" (modified bitumen), heat fused. 87. Dads: NC Incline: 1/4 Insulation: — Atlas Roofing "ACFoam II", Rmax "Mufti -Max FA ", Apache "White Line" or "Pyrox ", any thickness. Membrane: — "LS -FR" (EPDM), 45 or 60 mil. 88. Dedc NC Incline: 3/4 Insulation (Optional): — Any UL Classified, any thickness. Insulation: — Wood fiberboard, 1/2 in. thick min. Membrane: — "LS -FR" (EPDM), 45 or 60 mil. 89. Deck NC Incline: 1/2 Insulation (Optional): — "ISO 95+ GL ", wood fiberboard or perlte, any thickness. Membrane: — "LS -FR" (EPDM), 45 or 60 mil. 90. Deck: C -15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified, any thickness. Barrier Board: — G -P Gypsum DensDe ®, 1/4 in. thick min or gypsum wallboard, 1/2 in. thick min. Membrane: — "UltraPly" (TPA), 40 -100 mil. 91. Deck: NC Incline: 1 Insulation (Optional): — Glass fiber or perite, 1 in. max, mechanically fastened. Membrane: — One layer "SBS Metal Flash -AL" (modified bitumen), heat fused or hot mopped. 92. Deck: NC Incf)ne: Unlimited Insulation (Optional): — Polylsocyanurate, polylsocyanurate /perite composite, phenolic, phenolic/perlite composite, glass fiber, wood fiber or perilte, any combination, any thickness and /or EPS covered with min 1 in. pertte, wood fiber or 15/16 In. glass fiber. Base Sheet: — Type G2, one or more piles. Membrane: — "SBS Metal Flash -AL" (modified bitumen), heat fused. 93. Dedc C -15/32 Incline: Unlimited Insulation: — Polylsocyanurate, 1 -1/2 in. thick min, joints in Insulation offset 6 In. with joints In deck. Base Sheet: — One or more piles Type G2, mechanically fastened, spot or fully mopped. Membrane: — "SBS Metal Flash -AL" (modified bitumen), heat fused. 94. Deck. C -15/32 Incline: Unlimited • • • • • • • • • • • Insulation: — Periite or glass fiber, i in. thick min, joints in insulation off;A641 vkAo4>tsdn deck. Base Sheet: — One or more plies Type G2, mechanically fasten% spdt:r':'uIJ n1opDe4'; ' • Base /Ply Sheet: — One or more plies Type G2, hot mopped ire placer • • • • • • • • • Membrane: — "SBS Metal Flash -AL" (modified bitumen), heat fused. 95. Deck: NC Incline: 2 Insulation: — Perite, any thickness. 0 • • • • • • • • " "' Membrane: — "UftraPly" (TPA), 40 -100 mil., fully adhered VOM " Weter Bas Adhesive ", 1* 1/4 gal/sq. 96. Dedc. NC Incline: 2 i i i i • • • • i • • i • i • Insulation (Optional): — Polylsocyanurate, polystyrene (tapered or uniform thickness) or Ow Chemical "Styrofoam LG, PD, RM, SM, TG or STYROIB" any thickness or glass fiber, any thickness. ••• • • • • ••• • • 16 of 43 . �•••. � �•••� 11/18/2009 10:14 AM .•. . ... . . TGFUR9516 - Roofing Systems htip:H database. ul. com/ cgi- binAW /te"late/LISEX`T /IFRAME /show... Barrier Board: — Water resistant wallboard, 1/2 In. nom, joints in wallboard offset 6 In. with joints in deck. Insulation (Optional): — Atlas Roofing "ACFoam Ir or Rmax "Multi -Max ", any thickness. Membrane: — "RubberGard MAX" (EPDM), 45, 60 or 75 mil. 130. Deck. C -15/32 Incline: 1/4 Barrier Board: — Regular or water resistant wallboard, 1/2 In. nom, joints in wallboard offset 6 In. with joints In deck. Insulation (Optional): — Any combination of the following may be used: Perltte, wood fiber, glass fiber, any thickness. Insulation: — Wood fiber, 1/2 in. min. Membrane: — "RubberGard MAX" (EPDM), 45, 60 or 75 mil. 131. Deck: NC Incline: 1/4 Insulation: — Celotex "Hy -Therm AP ", "Hy -Tec ", "Hy -Tec II" ( "Energy- Lok "), "Top -R -II" or "Hy -Therm Tapered ". Membrane: — "FR" (EPDM), 45 or 60 mils, fully adhered with one of the following:. 1. Uniroyal bonding system. The membrane is adhered with "Royal M6504" bonding adhesive, applied at 60 sq ft/gal. The membrane laps are sealed with "Royal M6365" lap adhesive, applied at 75 sq ft/gal. The lap edges are caulked with "Royal 6346 ". 2. Ashland Chemical bonding system. The membrane Is adhered with "PLIOBOND 2375" bonding adhesive, applied at 60 sq ft/gal. The membrane laps are sealed with "PLIOBOND 9053" lap adhesive at 131 lin ft/gal. The lap edges are caulked with "PLIOBOND 5533 ". 132. Deck. NC Incline: 1/4 Insulation: — Celotex " Top -R -Ir or "Celo -Foam Ultra ", any thickness. Membrane: — "RubberGard MAX" (EPDM), 45, 60 or 75 mil. 133. Deck. C -15/32 Incline: 1/4 Insulation: — Celotex "Top -R -II" or "Celo -Foam Ultra ", any thickness. Membrane: — "RubberGard MAX" (EPDM), 45, 60 or 75 mil. 134. Dedc NC Incline: 1 Insulation (Optional): — Any UL Classified, any thickness. ( EPS must be covered with 1/2 in. min wood fiber, glass fiber, perlite or gypsum wall board). Base Sheet: — One or more pines Type G3, G2 or G3 or "MB Base Sheet", mechanically fastened or hot mopped. Membrane: — "SBS FR" (modified bitumen), hot mopped. 135. Deck. C -15/32 Ind: 1/2 Base Sheer — One or more layers "MB Base Sheet ", (Type G2), mechanically fastened. Ply Sheet: — One or more layers "Type 1V" or "Type Vr (Type GI), hot mopped. Cap Sheer — One layer "SBS FR" or "SBS Premium FR ", (modified bitumen), hot mopped. 136. Meted. 137. Meted. 138. Deck: NC Incline: 1/2 Insulation (Optional): — Any UL Classified polylsocyanurate, wood fiber, glass fiber or perlite, any thickness, hot mopped or mechanically fastened. Base Sheet: — "SBS Poly Torch Base ", heat fused. Ply Sheet (Optional): — One or more layers "Type Ar, "Type Vr, "MB Base Sheet ", "SBS Base Sheet ", "SBS Smooth ", "SBS Premium Base Sheet ", hot mopped or "SBS Poly Torch Base Sheet ", mechanically fastened in the sidelap, then overlap Is heat fused. Membrane: — One or more layers "SBS FR" or "SBS Premium FR" (modified bitumen), hot mopped or "SBS FR Torch Grade" (modified bitumen), heat fused. 139. Dedc C -15/32 Incline: See below Slip Sheet. —Two layers "VersaShield Underbayment" or "VersaShleld FB -2S ", preliminary attachment. Insulation: — Firestone "ISO 95+ GL" (any thickness), mechanically attached. Membrane: — Firestone .045 or .060; "LS-FR" (1/2:12); "RubberGard MAX" (1/2:12); "RubberGard MAX FR" (1- 1/2:12); UltraPly TPO ( 1/2 :12); EPDM membranes may be coated with "PC -100" at 1 gai/sq and maintain rating. 140. Deck: C -15/32 Incline: See below Slip Sheet: — Two layers "VersaShieki FB -1S ", preliminary attachment. Insulation: — Firestone "ISO 95+ GL" (any thickness), mechanically attached. Membrane: — Firestone .045 or .060; "LS -FR" (1/2 :12); "RubberGard MAX" or 75 mil (1/2:12); "RubberGard MAX FR" (3/4:12); UltraPly TPO ( 1/2 :12); EPDM membranes may be coated with "PC -100" at 1 gal/sq and maintain rating. 141. Deck: NC Incline: 1 -1/4 Insulation — Any UL Classified, any thickness, mechanically fastened. Insulation: — Oriented strand board, min 7/16 in. thick, mechanically fastened. n ra : — "UltraPly TPO" 142. Deck. NC Incline: 1/2 Insulat nal) — "ISO 95 +GL ", any thickness, mechanically attached. heet: — One layer "SBS Glass Base SA" or "MB Base SA ", self adhered. Membrane: —"SBS Premium FR ", "SBS Premium FR Torch Gr dam, nSB P� ",� S�3 fR` "18S, FWTorrh Grade ", "SBS Glass FR", SBS Glass FR Torch Grade ", "APP 180 FR and Rhoftex FR , hot mopped or�freatifused. • • 143. Deck NC Incline. 1/2 • • 0 : : : i : : • Insulation — "ISO 95 +GL", any thickness, mechanically fasten • * 0 • • a 0 • • • Membrane — "Platinum" (EPDM), fully adhered with "BA 2004 ", 1 -2/3 gai/sq. 144. Deck: NC Incline. 3 -1/2 •• • • ••• ••• ••• Insulation (Optional) — Any UL Classified, any thickness, Mechamlca_ly attached. Barrier Board — G -P Gypsum DensDe ®, 1/4 In. thick, mjAvn4ally f lAtene8. . • . • Membrane: — "Platinum" (EPDM), fully adhered with "BA 200 •, P J)3 gal/Sj! • • • 145. Deck NC Incline: 2 -1/2 ••• • • • • ••• • • 19 of 43 ��• :•�•: ••• V 11/18/20099 AM GEOTECHNICAL ya''' TESTING LABORATORIES ENVIRONMENTAL - — DRILLING SERVICES HYDROGEOLOGY INSPECTION SERVICES 'ASBESTOS ROOFING Miami, November 11, i3 YNATECH 09 E N G INEERING CORP. Mr. Jeff Anderson SERVICE WORKS 5423 North 59' Street Tampa, FL. 33610 Re: Bank of America @ 9499 NE 2 °d Avenue Miami Shores, FL. Dear Mr. Anderson: Pursuant to your request, DYNAT8CH ENGINEERING CORP. conducted an Asbestos Roof Survey on November 9, 2009 at the above referenced project. The purpose of our inspection was to secure bulk samples for analysis to determine the presence of Asbestos Containing Materials in the proposed renovation area. Access to the interior underside of the roof was not provided and is not part of this survey. The scope of our inspection covered the following areas: Roof at the above referenced project. (see attached plan) Based. on our laboratory analysis; it was evident that no asbestos fibers were found in the secured bulk samples. This inspection report is the results of a customary search of the facility for asbestos containing building materials (A.C.B.M.). This survey was destructive in order to expose potential hidden materials. We do not claim to have identified all of the asbestos containing building material present in the facility. If in the course of a renovation or demolition activity, suspect materials become exposed, (ie: inside walls and hidden conditions etc..,) all activities should immediately cease and the suspect material brought to our attention for evaluation and recommendation. Dynatech Engineering Corporation (DEC), will not be responsible for these conditions. It has been a pleasure serving you at this phase of your project and look forward to do so in the near future. YO Wis Naamani, P.E. • • DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 •• • • +• ••• ••• Asbestos Consultant No. EA 0045 • • • . • ..... . . . . . Asbestos Business No. ZA 0000045 • • • • • • • • 750 West 84 Street, Hialeah, FL 33014 -3618 - Phorge: b.01i 8Y$7 , J99; • F4i: (305) 828 -9598 E -Mail: Dynatech a 13eflsouth.net • • • ` • Pmod W DYNATECH ENGINEERING CORP. ASBESTOS SAMPLING REPORT 750 W. 84th Street, Hialeah, FL 33014 )ate : November 10, 2009 ;lient : SERVICE WORKS 'roject : Bank of America @ 9499 NE 2 nd Avenue, Miami Shores, FL. surveyor No. 09132004 ;ample T e Bulk SamiDles Analysis: P.L.M./D.S. Sample Approximate Condition Analysis No. Location DESCRIPTION. Amok F NP Potential for Damage 1 North perimeter Flashing plastic cement 3201inear X G/L NAD feet 2 North perimeter Flashing plastic cement N/A X GIL NAD 3 North perimeter Flashing plastic cement N/A X G/L NAD 4 North perimeter Flashing plastic cement N/A X G/L NAD 5 North perimeter Flashing plastic cement N/A X G/L NAD 6 West perimeter Flashing plastic cement N/A X G/L NAD 7 West perimeter Flashing plastic cement N/A X G/L NAD 8 West perimeter Flashing plastic cement N/A X G/L NAD 9 West perimeter Flashing plastic cement N/A X GIL NAD 10 NE field Built up tar and gravel over 1200 ft X G/L NAD fiberboard insulation over another BUR tar and gravel over wood F = Friable Condition Potential For Damage NF = Non Friable G = Good L = Low NAD = No Asbestos Detected D = Damaged M = Medium CHRY = Chrysotile S = Significantly Damaged H = High DYNATECH ENGINEERING CORP. Analyzed by: Premnath Boodoosing McCrone Research Institute Microscopical Identification of Asbestos No. # 09132004 . . • • • . • ... . • . • . • •. • • • • • • • • • • • •• •• •• ••• • • • • ••• • • • • • • • • • V • • i•• • • • • • •• • • • •• • • ••• • • t DYNATECH ENGINEERING CORP. _ASBESTOS SAMPLING REPORT 750 W. 84th Street, Hialeah, FL 33014 )ate : November 10, 2009 :lient : SERVICE WORKS 'roject : Bank of America @ 9499 NE 2 nd Avenue, Miami Shores, FL. zrveyor No. 09132004 yam le a Bulk Samiples Analysis: P.L.M./D.S. Sample - .Approximate Condition Analysis No. Location DESCRI MON Amount F Potential for Damage 11 North field Built up tar and gravel over fiberboard N/A X G/L NAD insulation over another BUR tar and gra vel over wood 12 North field Built up tar and gravel over fiberboard N/A X G/L NAD insulation over another BUR tar and gr avel over wood 13 NW field Built up tar and gravel over fiberboard NIA X G/L NAD insulation over another BUR tar and gr avel over wood 14 West field Built up tar and gravel over fiberboard N/A X G/L NAD insulation over another BUR tar and gr avel over wood 15 SW field Built up tar and gravel over fiberboard N/A X G/L NAD insulation over another BUR tar and gr avel over wood 16 SW field Built up tar and gravel over fiberboard N/A X G/L NAD insulation over another BUR tar and gr avel over wood F = Friable Condition Potential For Damage NF = Non Friable G = Good L = Low NAD = No Asbestos Detected D = Damaged M = Medium CHRY = Chrysotile S = Significantly Damag t • H = Hi h • • • � +044 � >«l 1AN EERING CORP. •• 00 ftalytedvby'Premtiath Boodoosing McCrone Research Institute •• • Micsoscapical i&vtifw,&tion of Asbestos % :: No:49122004 • • • • • • • • • • • • • • • • ••• • • • ••• • • r r ROOF ASBESTOS SURVEY } 9499 N.E. 2ND AVE MIAMI SHORES,FL N 75 1 2 3 12 10 UPPER 11 FLAT ROOF 13 9 5 4 SHINGLE ROOF 14 85 LOWER 6 FLAT ROOF 15 8 16 7 ROOFS NOT TESTED Dynatech Engineering Corp Client: Scale: SEVICE WORKS COMMERCIAL N.T.S. Project: Date: 9499 N.E.2 AVE MIAMI SHORES, FL 11 -10 -09 s # r v r � aD / 000 l 2,?, DERM PIAN REVIEW FINAL APPROVAL UEP'AWTMETNT OF ENVIRONMENTAL RESO RCE`Sj N CsEMENT CI IR49 REVIE SIGNATU DATE "17 � GEOTECHNICAL TESTING LABORATORIES ENVIRONMENTAL . ' DRILLING SERVICES HYDROGEOLOGY INSPECTION SERVICES ASBESTOS ROOFING DYNATE EN CO RP. Date : October 20, 2009 Client : SERVICE WORKS COMMERCIAL ROOFING, INC. Project : Bank of America @ Address :9499 NE 2 " Avenue, Miami Shores, FL. ASCE 7 -05 DESIGN PRESSURE CALCULATIONS Proiect Info: H = 32' Exposure: C Basic Windspeed V =146 MHP L = 85' Category : II Importance Factor 1 =1.00 W= 75' slope: < 10° Kz— 0.99 K =1.0 Kt Parapet Wall: < 3' Design Calculations: Velocity Pressure: q = 0.00256 (0.99) (1) (1) (146) (1.0) = 54 PSF Width of Pressure Coefficient: 0.1 (75') =7.5' 0.4 (32') = 12.8') use 7' - 6 " Approximate Tributary Roof Area: <10 Sq...Ft. For parapet height 3' or larger zone 3 & 4 can be tpeated as zone- 2.(ASCE 7-05) . ......... . .• . . 0. 0 ..... . . . . . . . . . . . .. .. .. 4, • 750 West 84 Street, Hialeah, FL 33014 -3618 - Phone: ;3fl5i E$ 7499; .F4j: (305) 828 -9598 E -Mail: Dynatech@11;t1south.net ft� . Page No. 2 9499 NE 2 " Avenue, Miami Shores, FL. External Pressure Coefficient: 1) GCPj _ -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: ± 0.18 Design Pressures: 1) Field : P1= 54 ( -1.0 ± 0.18) _ -54 PSF 2) Perimeter P2= 54 ( -1.8 ± 0.18) _ -98 PSF 3) Corners P3= 54 ( -2.8 # 0.18) _ -151 PSF Attachment Requirements: A- Wood Deck Areas # 2 and # 3 Based on N.O.A. # 08- 0118.07 page 28 of 30 option # 2; the following are our recommended fastening pattern: Field: 6 o.c. @ laps and 3 staggered rows 6" o.c. Perimeter: 6" o.c. @ laps and 4 staggered rows 6" o.c. Corners: 6 o.c. @ laps and 5 staggered rows 6" o.c. B- Concrete Deck Areas # 1, # 4, and # 5 Based on N.O.A. # 08- 0716.01 page 8 of 15; system acceptable as approved with -540 psf with oly bond or - -442.5 PSF with all of the listed insulation adhesive > -151 PSF. i t v Page No. 2 9499 NE 2" Avenue, Miami Shores, FL. External Pressure Coefficient: 1) GCP, _ -1.0 2) GCP2 = -1.8 3) GCP3 _ -2.8 Internal Pressure Coefficient: ± 0.18 Design Pressures: 1) Field ; P1= 54 (4.0 ± 0.18) _ -54 PSF 2) Perimeter P2= 54 ( -1.8 ± 0.18) _ -98 PSF 3) Corners P3= 54 ( -2.8 ± 0.18) _ -151 P Attachment Requirements: A- Wood Deck Based on N.O.A. # 08- 0118.07 page 28 of 30 option # 2; the following are our recommended fastening pattern: Field: 6 o.c. @ laps and 3 staggered rows 6" o.c. Perimeter: 6" o.c. @ laps and 4 staggered rows 6" o.c. Corners: 6 o.c. @ laps and 5 staggered rows 6" o.c. B- Concrete Deck Based on N.O.A. # 08- 0716.03 page 7 of 12; system acceptable as approved with -262.5 psf > 151 psf. . ......... . .. ... .. . .... .. . . ... ...... ..... . . . . . .... .. .. .. .. .... ....... . ..... ... . ...... . .... .... . . .... . M . .. ... . . .. .. . . . . . . . . . . ... . . . . ... . . .... .. .. .. .. . . . . . . . . . . .. . . ... ... ... .. ... •• • . . •• . ......... . ....... . .. .. M t Page No. 3 9499 NE 2 nd Avenue, Miami Shores, FL. Notes: Corners, extended corners and perimeter area dimension shall not be less than a= 7' -6 ". All work shall be in compliance with the local building code, product control notice of acceptance and manufacturer Specifications and Florida Building Code. Wind load calculations are based on ASCE 7 -05 and information provided by client. Roof uplift capacity shall be verified in compliance with Florida Building Code Protocol TAS -124. (when applicable). All work shall be inspected by our field engineer or City Inspector to verify compliance with specifications. In the event of exposed ceilings; the engineer must be notified to verify applicability of fastening pattern and penetration. Sincerely yours, lr� Wissam Naamani, P. E. DYNATECH ENGINEERING CORP. Engineer Florida Reg. No. 39584 Special Inspector No. 757 ....... . . • .. . •. . . . • . . .. . . . . ••• . .• ••• .. . • • .. .. . . ..• ...... .. . . • . ..... . . . . . .•• . GEOTECHNICAL TESTING LABORATORIES ENVIRONMENTAL _ DRILLING SERVICES HYDROGEOLOGY INSPECTION SERVICES AS`i§ESTOS ROOFING DYNA TECH ENGINEERING CORP. ROOF DRAINAGEC FLATIONS Date: October 20 2009 Client: Service Works Commercial Roofing Project: Bank of America a@ Address: 9499 NE 2 nd Avenue, Miami Shores, FL. Roof Area / Level: 1 / 32' High / Wood Deck Projected Roof Area: (sq.ft): 2800 ft A. Existing No. of primary drains: 3 Existing size of primary drains (W): 3" O Total area of primary drains (W): 21.21 W Per Table 1106.2 FBC Plumbing Section: Rain Fall Rate (in/hr): 5 Required -area of primary drains: 10 W < 21.21 W = Good as is. B.. Required area of Emergency drains Fig. 16173: N /A, Drip Edge Existing No. of emergency drains: 0, Drip Edge Existing size of emergency drains (i&): N /A Total Area of emergency drains (inz): N /A Notes: roduct control notice All work shall be in compliance with local building codes, p inspected by the of acceptance NoA and manufacturer specifications, and shall be building official or our representative to verify compliance with specifications: Contractor shall verify roof deck slopes upon tear off. if proper sl top es roofing provided to drains; the contractor must provide proper sloping p rior or relocate drains. Drain attachments shall be in compliance o the manufa specifications Building Code FBC 2007 Roof drainage calculations are b revisions and information provided by client. • • • • • Sincerely -C i • • • i i • • • Wis • Nagmwai,.P.E�. ... . DYNATEGI•I•EN*W��4 T.CV•: Florida Reg. NB 305$4 •' V : : • special Inspector No. 757 750 West 84 Street, Hialeah, FL 33014 -3618 ° Phone: 1310; J1J- 7a99. (305) 828 -9598 E -Mail: Dynatech @1fcllsoutt �nef "• PmW � GEOTECHNICAL , TESTING LABORATORIES ENVIRONMENTAL DRILLING SERVICES HYDROGEOLOGY INSPECTION SERVICES AS13ESTOS ROOFING DYNA TECH ENGINE CORP$ ROOF DRAINAGE CALCULATIONS Date: October 20, 2009 Client: Service Works Commercial Roofing Project: Bank of America @ Address: 9499 NE 2 nd Avenue, Miami Shores, FL. Roof Area / Level: 2 / 22' High / Concrete Deck Projected Roof Area: (sq.ft): 3575 ft A. Existing No. of primary drains: 2 Existing size of primary drains (in 4" 0 Total area of primary drains (in 25.14 in Per Table 1106.2 FBC Plumbing Section: Rain Fall Rate (in/hr): 5 Required area of primary drains: 12 in < 25.14 in = Good as is. B. Required area of Emergency drains Fig. 16173: 50 in Existing No. of emergency drains: 2 Existing size of emergency drains (in 6" x 12" Total Area of emergency drains (in 144 in > 50 in => Good as is. Notes: All work shall be in compliance with local building codes, product control notice of acceptance NoA and manufacturer specifications, and shall be inspected by the building official or our representative to verify compliance with specifications: Contractor shall verify roof deck slopes upon tear off. If proper slopes are not provided to drains; the contractor must provide proper sloping prior to re- roofing or relocate drains. Drain attachments shall be in compliance. with manufacturer specifications. Roof drainage calculations are based on the Florida. B> g(� ng Gods FBC -2007 revisions and information provided by client. . ......... . • . • . • .. ... .. . .... Sincerely ours, V sam Naamani, 11.1; • * -- -, - : 0 : 0 ; • DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 ... . .. . . ... . . 750 West 84 Street, Hialeah, FL I" ` (b5x82�70% ° �a4: (.3 05) 828 -9598 .. • . . .. &Mail: Dynatech @Bcllsm6.net . . • . 000 • . • PMMd PAwW .�P GEOTECHNICAL TESTING LABORATORIES ENVIRONMENTAL r - DRILLING SERVICES HYDROGEQLOGY INSPECTION SERVICES ASBESTOS ROOFING DYNAT ENGINEERING CORP. Miami, October 20, 2009 Mr. Jeff Anderson SERVICE WORKS COMMERCIAL ROOFING 5423 North 59` Street Tampa, FL. 33610 Re: Bank of America @ 9499 NE 2 " Avenue Miami Shores, FL. Dear Mr. Anderson: In accordance with your authorization, DYNATECH ENGINEERING CORP. performed a Roof Moisture Survey in compliance with TAS -126 and the Florida Building Code on October 16, 2009 at the above referenced project. Dynatech Engineering Corp. is a certified Dade County Testing Agency. The purpose of our inspection was to determine the moisture content of the existing roof. This is not a roof top inspection, this is a roof moisture survey only. The subject building consists of a (2 and 3) story CBS structure the 2 -story structures consists of built up tar and gravel roof system over perlite insulation over another smooth built up roof system over concrete roof deck. The 3 -story structure consists of built up tar and gravel roof system over fiberboard insulation over another smooth built up roof system over a wood roof deck. On October 16, 2009 our field engineer visited the site and conducted a nuclear moisture survey. In addition 6 core samples were secured to verify the oven dried moisture content. All tests were performed according to the Florida Building Code and the Rao cans 0 i t tandard P g g � ����t� Practice for the Detection and location of Latent Moisture in Building mo� $is - ?Y Nuclear Radioisotopic Thermalization using a Troxler model 3216. * 10 .. 000 000 000 0000 .. .. .. .. 0000 0000... 750 West 84 Street, Hialeah, FL 33014 -3618 ® Phone: (305):828s7499 ® Fax► ( ) 828 -9598 0000.. . 0000 E -Mail: Dynatech@Bcllso4h.;et • • • • c r Page No. 2 9499 NE 2 " Avenue, Miami Shores, FL. The following is a summary of the core test results: OVEN DRIED GRAVIMETRIC ANALYSIS DECK TYPE % MOISTURE Core No. CC -1 CC -2 CC -3 CC -4 CC -5 CC -6 Core Location: A -14 D -2 N -2 H -10 I -17 N -11 BUR Tar and gravel 0.6 0.4 0.3 0.9 1.4 1.9 Fiberboard Insulation 0.8 0.5 0.4 N/A N/A N/A Perlite Insulation N/A NIA N/A 4.8 31.7 37.2 Smooth BUR 0.5 0.6 0.6 3.2 3.0 3.5 Nuclear Reading 31 23 15 41 43 49 Nuclear test results are presented graphically thru a histogram in the appendix. Pursuant to the Florida Building Code Section 1521.12; the moisture content of the existing roof system shall not exceed 5% by weight in the roof membrane and 8% by weight in the insulation system. The moisture content of the existing roof deck was found in compliance with the Florida Building Code, TAS -126 at the time of our inspection, however elevated moisture levels were detected in the lower roof perlite insulation as shown on the attached sketch. ....... . .. .. . ......... . .. ... .. . .... .. . • ... •.. ••. :0. • . 0.0 ... . . . . • • . • • . •• • . ..... . ... . •• •• . . . •• •• ••• • • • ••• • • Page No. 3 9499 NE 2 " Avenue, Miami Shores, FL. The test results presented here, reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof conditions are continuously changing due to exposure to the elements and roof top traffic. It has been a pleasure serving you at this phase of your project and look forward to do so in the near future. Sincerely yours, 115�UA- ssam Naamani, P.E. DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 Special Inspector no. 757 .. ..• . . . . . .• ....... • . . . • see ... .. . .... .. . . ... ... ... . . . . .. . ... . . . . . . . . . . . . •. .. .. . ..... . ... . . .... ...V 9 : . .... . DYNATECH ENGINEERING CORP. MOISTURE GRAVIMETRIC ANALYSIS 750 W. 8e Street, Hialeah, FL 33014 DATE : October 20, 2009 CLIENT : SERVICE WORKS COMMERCIAL ROOFING, INC. PROJECT : Bank of America @ ADDRESS : 9499 NE 2 Avenue, Miami Shores, FL. TEST NO. AND DESCRIPTION Moisture % CC #1: BUR tar and gravel 0.6 Fiberboard Insulation 0.8 Perlite Insulation N /A Smooth BUR 0.5 CC #2: BUR tar and gravel 0.4 Fiberboard Insulation 0.5 Perlite Insulation N /A Smooth BUR 0.6 CC #3: BUR tar and gravel 0.3 Fiberboard Insulation 0.4 Perlite Insulation N /A Smooth BUR 0.6 CC#4: BUR tar and gravel 0.9 Fiberboard Insulation N /A Perlite Insulation 4.8 Smooth BUR 3.2 CC #5: BUR tar and gravel 1.4 Fiberboard Insulation N /A Perlite Insulation 31.7 Smooth BUR 3.0 CC #6: ....... • .. .. BUR tar and gravel 1.9 •. •; 0 0 0 0 0*: : ' • ••• •• • • • •• Fiberboard Insulation N /A Perlite Insulation 37.2 • • • ... 0 Smooth BUR 3.5:' • :: • ' •' + . . •• •• V • • • • • • • • • • • ••• • • • ••• • • I 25 t�l 1Q 15 16 2cs 18 26 16 N 15 0 4 tei 2 ?4 5 ZT 29 23 ib 15 21 ® 17 15 16 23 i4 813 3 23 22 2$ 21b 15 Zo 16 20 13 17 26 2� 15 11 4 18 17 lq 21 2H i�. ►6 t3 Ib 1 17 15 23 is 1 17 L£GF-t4© 9 0 -42 D ry zQ a7 as w 7 43 Wet 7 2z z3 + 2c 8 2F4 t8 IC- tq q za 115 Z,1 lq 27 z,9 � 24 2q J5 � 32 0 = Core Cuts to 27. 2 ` 4 V7 7.2 0 36 7 36 ?',4 8i it 25 t4 17 '2t 81 93 28 3a f9 H8 •••• l2 23 18 ly -Z Is 30 37 3q 27 2L •Z% i••••i •• • �••� (3 30 1S 18 21 34 34 35 U a- 23 ••si•• �••sr • • 3t 20 2t 17 L37 4z 3Z 33 2b 27 33 26 •i•••• • •• "s• •• 15 Z5 15 i7 37 3«1 ••�•• • •• •••••• 24 tic 15 ►4 3t 33 32. • • •!••ai 0 *000 • 17 2t 1Q tea 2i 3 3:{ 2b 3u ZCs 25 •••••• •••••• • •••••• A C D G • Dynatech Engineering Corp. Client Scale: SERVICE 'WORKS COMMERCIAL I N.TS. Project: 9499 NE 2 Avenue Date: Miami Shores FL. w 4t rP a 3vv Nov 18 100 000 00, • • • • • •• • • �j` "' 1T s 00 �• -• .• Miami Shores V ilag9 APPROVED BY DATE • • • • • • : ••: ZONING DEPT BLDG DEPT i 0 SUBJECT TO COMPLIANCE NTH ALL FEDERAL • • • ,. •• 0 � �••�� STATE AND COUNTY RULES AND REGULATIONS Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: I NSP- 132916 Permit Number: RF -11 -09 -1914 Scheduled Inspection Date: January 08, 2010 Permit Type: Roof Inspector: Bruhn, Norman Inspection Type: Tin Cap Owner: , Work Classification: Tile/Flat Job Address: 9475 NE 2 Avenue Miami Shores, FL 33138- Phone Number Parcel Number 113206013376 Project: <NONE> Contractor: SERVICE WORKS COMMERCIAL RO OFING, INC Phone: (813)626 -7717 Building Department Comments LOW SLOPE - FIRESTORE MODIFIED BITUMEN RE -ROOF Infractio Passed Comments TIN CAP SPACEING False STEEP SLOPE- OWNERS CORNING SHINGLE ROOF Inspector Comments Pass��Z A5 " Failed Correction ❑ Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. January 07, 2010 For Inspections please call: (305)762 -4949 Page 21 of 41 01/07/2010 15:44 8136267248 SERVICE WORKS OF TAM PAGE 01 SERVICE w N. f r; k J •. .. •al • .}h. ¢.i 4 , �� � n ��'. x r• s." a. w. a:..•. ..• a..:: rn..- n ro+. rn-+ r. n:.-:. s -.k» WOR .. ., YOUR FULL SER VICE R CONTRACTOR Date: ,January 7, 2010 Pages: 1 of 3 To Jr. Garza or German Zuniga — Service Works Company: c/o Homestead Studio Suites Miami Blue Lagoon Phone: 305- 260-0085 Fax: 3 2600042 Su ue Heate r Re: Lookin Pocket Specs j PLEASE HOLD AT FRONT DESK FOR PICKUP. a THANKS i Service Works 5423 North 5e Street Tampa FL 33610 Phone 813- 826 -7717 F=813-626-1248 www.servicewoftmofing.com 0110712010 15:44 8136267248 SERVICE WORKS OF TAM PAGE 02 ]FEATURES AND BENEFIT one wis Technoloqv mo solvents • Easy to apply • Low odor a ther 10, ek * T40 mixing • VOC free No temperature • No name hazards restrictions a 100% solids • Saves labor High strength Elaistomeric No flashing needed •w Flexible Lo ckin' P��cket • Absorbs stresses Inter-Locking Pitch ;.::: :. �; :, -::. ' ': Pocket System PRODUCT DESCRIPTION Weather -rite Lockin' Pocket Inter - Locking Pitch Pocket System is a pre- fabricated Inter-locking pitch Pocket system that Is easily assembled on site and filled with fast setting, solvent free, multi-use Weather- Weqther_'nt;.- Locktn' filled wO Wwrionr row I Sevier Tito Hurricane Force Universal Sealer that becomes waterproof within Minutes of application. APPLICATION LockIn' Pockets are available in different packaging options; the prefabricated pockets simply connect with tongue and groove joints and are composed of a high 1. Make sure substrate is clear of loose grave, dirt, strength, Hexlble polyurethane elestomer. All pieces granules, or all foreign Substances that car affect are easily joined by a Went pending locking system to adhesion. Refer to Surface Preparation guic ellnes. create a pocket of desired size. 2. Place Lockin' Pocket In desired location an mark the outside edge for reference. Lockin' Pocket should be placed to assure at least one (1) inch dower nee from BASIC USE the inside of the Loddn' Pocket and pens tn ition. Lockin' Pockets are designed to seal technically 3• Penetrations should be prepared by wire br Ahing challenging wetrations, where field flashing may not be to remove loose cements, sealers, HAStr or 3ther practical cont"MInants that would prevent a posItIvc seal. 4. Seal base of penetration with weather -Tire LPS, When installed and filled with Weather -Tate Hurricane sealant to prevent the potential of Hurricar e Force Force Universal Sealer, the Locktn' Pocket Inter-Locking Universal Sealer flowing through openings. Pitch Pocket System becomes a long tasting waterproof 5. Apply a liberal bead of LPS to the substra where solid maw that can make the most challenging Lockln'Pockets will be placed. penetrations watertight in minutes. 6. Apply a liberal bead of LPS to the lacking )Int of the Lockin' Pocket. APPROVED MEMBRANE SUBSTRATES 7. Set Lockin' Pocket In place and apply equa pressure Granule surfaced Modified Bitumen to assure positive contact with the roof su • r--PDM 8 Strike away excess sealant. • • TPO 9. Dispense an initial amount of weather-Tite Hurricane • Metal Force Universal Sealer to ensure a proper i nix. • Smooth surfaced asphalt Built-up roofs (BUR) Ia. Fill assembled pocket with Weather -Tits HL rricane Gravel surfaced BUR (asphalt & coal tar pitch) Force Universal Sealer until full. For a complete list of approved substrates, or for additional information, contact our Technical Department. SYSTEMS !@OD Agr oh; 0 A Afflietimium Adtve2i* n)paq WTT Systems - Roofing Division x A Millennium Adhesive Compony ■ 888_5 4.9733 ■ wttus.com it 01/07/2010 15:44 8136267248 SERVICE WORKS OF TAM PAGE 03 PACKAGING AND COVERAGE weather Tte Lockin' Pocket Inter•Locldng Pitch Pocket Systems are packaged in a variety of assembly options. Contact your local sales representative or our summer .. :: Service Department for details. For example, 4" One .a' # #' •Ir Piece Kit (shown at left) includes 6 (six) 4" Lockin' I Pockets and 2 tubes of Weather -rite LPS sealant. The „u 8/8 U -Build Component Kit (shown below) includes :nu•• •+'" `r' 8 outside corners 9 8 -6" stoat hts. and 2 tubes of LPS ` sealant. When used as a pitch pan sealer, one cartridge of Weather -Tlte Hurricane Force Universal Sealer will yield approximately 90 Cubic inches of feller. SURFACE PREPARATION All work suffaces should be clean, dry, and free of dirt, dust, debris, oils, loon and/or embedded gravel, un- adhered coatings, deteriorated membrane and other �.,. contaminants that may result in a surface that is not sound or is uneven. Penetrations should be prepared by ° wire brushi ng to remove loose cements, sealers rust or other contaminants that would prevent a positive seal. When Lockin' Pocket Is to be installed on a Single ply membrane, the surface of the membrane must be :'•.^ : ~ : ; Prepared according to the single ply manufi Mrer's recommendations. As a general guideline the following methods of surface preparation shall apply: • EPDM -clean with Splice wash surface cleaner and prime EQUIPMENT . TP4 - Clean with surface cleaner and prime The fast and dependable One Step applicators make OP- Gravel BUR'S -Remove gravel surfacing down to plies plying Hurricane Force Universal Sealer simple: For applications over existing weathered asphalt or coal • Battery Powered Single feed tar pitch built -up roof membranes apply Weather -rite • Pneumadc Single Bead Universal Primer prior to Lockin' Pocket irratMllation. For applications over fresh or noon - oxidized asphalt, coal tar pitch, or plastic film membranes apply weather -Tito Sur - WARRANTY face Treatment prior to Lockin' Pocket Installation. W1'i' Systems, LLC guarantees this product to be free of manufactured defects for the shelf life period of 12 STORAGE months from date of manufacture. All claims must be made In writing within 12 months of the original Keep temperature of contents between B5 -85 °F purchase. (18 0 C ^29 11 C) 24 hours prior to use. Do not store in direct sunlight or high temperatures 90 6 F (32 0 C) and higher, contractor shall verify that the Weather -Tate Hurricane Force Universal Sealer has been property mixed and cured before leaving the site. SAFETY For detailed information regarding 14 year, 3.S year or Prior to working with any product, be sure to read 20 year extended term system warranties, contact our labels and the Material Safety Data Sheet (MSDS). Take Technical Department, necessary health and safety precautions. LIMITATIONS • Do not apply to wet or damp surfaces . Do not use grout or any other type of fillers • Lockin' Pocket must be on a flat, level substrate, and is not intended for steep slope applications COLOR SYSTEMS Roonp, 0 - kin mAt slack A mniun ArMesrve Company �n WTT Systems Roofing Division s A Millennium Adhesive Company ■ 888564.9733 n wttus.com i I