Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
44128
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 1 /25/99 JobAddress 11300 NE 2nd Avenue Tax Folio 302231°023.0010 M' mi Shores, FL 33161 LegalDescriptian See Attache IistoricallyDesignated: Yes No XX . Owner/Lessee /Tenant Barry ljrlversity Thompson Bldg. Master Permit# n/a Owner's Address 11300 NE 2nd Avenue Miami Shores, FL phone (305) 899 -3052 33161 Contracting Co Allied Roofing Industries, Inc. Qe. Marcial I. . Garcia Stedte# CCC 044009 lvfatgagi n/a Permit Type (circle one): WORK DESCRIPTION S ture of o r k ®i sA 'Address 5Zaf r /r ea/iv-tut 1_57) ddress L =%-kit FL. ,3C)lra 335 Squares Notary as to Owner and/or Condo Presi My Commission Expires: esi% Christina Martinez *My Commission CC745003 1+,� / Expires May 25.2002 a Address 7050 NW 42nd Street ` � 305 / Address NIA LECTRICAL PLUMBING MECHANICAL OOFING AVING FENCE Re—roofing C OGvM r,/-e p t G 4 el -L, /r app ref .s OWNER'S AFFIDAVIT: I certify that all the foregoing information is laws regulating construction and zoning. Furthermore, I authorize the abo BAIL ea-Li um( ER. 5 ,1 e 7 , /2 6(9 9 er and/or Condo President �Datt � c a / sic v F a c t fl -e AC-11 � , 99 Date FEES: PERMIT 1005 RADON C.C.F. ur 11 SIGN $ 191,400:00 Square Ft Estimated Cost (value) WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK that all work will be done in compliance with all applicable contractor to do the work stated. D )2OOFING INDUSTRIES, INC. 1/25/99 f Contractor or Owner - Builder Date CO): Notary as t Contractor orOwner- Builder Date My Commission Expires: March 31, 2000 1/25/99 A MARIE FORMEL h f i kr My Commission CC5432/ ♦I Expires Mar. 31,200 aF Q r NOTARY BOND At 3 0 D- TOTAL DUE / 1 ,62.0 v g APPROVED: 1.. ,y Zoning Building I ) r zl k Electrical Mechanical Plumbing Engineering a .. CONTRACTOR Miami Shores Village, Fla. OWNER G�^f' DATE `oZl 4 ADDRESS �'.. INSPECTION TIME READY 9 J. � • PERMIT NO. .41i 04 . ..faigi TELEPHONE NO. Y47,- 73'/c INSPECTOR DATE it A RECORDED COPY 11 ST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. .302231 023001 0 STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: See Exhibit "A" for legal description. 11300 NE 2nd Avenue Miami Shores, FL 33161 2. Description of improvement: Building 2 - Thompson Hall - Re -roof 3.Owner(s) name and address: Barry University of 11300 NE 2nd Avenue Interest in property: Owner - Fee Simple Name and address of fee simple titleholder: 4. Contractor's name and address: Allied Roofing Industries, Inc. 5. Surety:(Payment bond required by owner from contractor, if any) Not Applicable Name and address: •o1 Print Owners Name Miami Shores, FL 33161 Amount of bond $ Not Applicable 6. Lender's name and address: Not Applicable 7050 NW 42nd Street Miami, Florida 33161 Not Applicable N/A Sworn to and subscribed before me this 23rd day of Notary Public Print Notary's Name My Commission Expires: / (a et 31, Q E500 STATE OF FI-ORI')4, COIJNTY f) DADE 4.HEQE3Y Cc12i1rY }.'gyp If,L.:: a I •a. rf the fled o.'H,•- on � 01 Ai) t4 W LV ::h5 •.i h. „d 11/3ut•vLi \, ...f 8 Miami Shores, Florida 33161 98R628C132 1998 DEC: 28 13 :05 Barry University 11300 NE 2nd Avenue 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provide by Section 713.13(1)(a)7., Florida Statutes, Name and address: N/A 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recordi different date is specified) 1 Year F ' 7 — gsrn 4 - 47 t/»V v TtL s r.27 9 Print or type ame o Notary Personally k own or Produced MI J Type of ID produce, & In number By Freddy Ulloa, .Assoc . VP Facilities Mcm epared by: A.M. Formel December1998 Allied Roofing Indust 7050 N W ���r "tJSfr� 40011:1:"4„. ° A MARIE FORMEL Address: >¢ E r os mmiesb„ ccsasa7o Miami, Florida 33161 13(251 $$ /D y. unless a 123.01.52 Exhibit "A" LEGAL DESCRIPTION NOC: 98R628032 in Dade County, FL Recd.: 12/28/98 Street: 11300 NE 2nd Avenue, Miami Shores Subdiv: SEC 36 -52-41 barry university - THOMPSON HALL Exhibit "A" LEGAL DESCRIPTION NOC: 98R628032 in Dade County, FL Recd.: 12/28/98 Street: 11300 NE 2nd Avenue, Miami Shores Subdiv: SEC 36 -52-41 barry university - THOMPSON HALL 'sd °�'r'�. -- Le.r5 ' 7 li o - ? y oeo a: Vii=. �.� Contractor's Name: Job Address: ° (Low Slope Application) ❑ (Asphalt/Fiberglass Shingles) 123.01.76 9198 ❑ New Roof F t. ir l Ft. A V O Deck type: l _LI ATTACHMENT Fastener Type: )01/1 SPACING Field: OA Perimeter: Cornea /' 1 1 & 2 Page -1 PROCESS No. 8E ROOF CATEGORY + + Sh` 5 FL- 3161 ❑ (Nail -On Tile) ❑ (Mortar- Adhesive Set Tile) ❑ ( Metal Roofs\Wood Shingles & Shakes) ❑ (Other) ROOF TYPE e- roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft Sloped Roof Area (ft ` Total (ft 0‘ Master Permit No. Exposure category (per ASCE 7-88): C., Building Classification category (per ASCE 7-88 table 1): ROOF HEIGHT AND SYSTEM DETAIL .�- t ,- (Draw details as needed) VS �� l mu _ f t tri2 t : g2 . h1/4.9 OA r r r r Et r r • 91 1 4 1 9 0 5 ( C ) I F PLAN 1 1 , , 1 1 , _ 1 ; 1 - ' - - - -- • 0 • • • • • • ------------------------------- - - - - -- Ridge Ventilation? MEAN HEIGITT Deck type: z Underiayment: D E T A I L 3 • 1Z 11001P SLOP! 1Pmax1' x X (Aerodynamic Multiplier): ) - M fmax2: x a, (Aerodynamic Multiplier): ) - M i 'mod: x ? (Aerodynamic Multiplier): ) - M _ . - _ -.... a AA. ..2r r Saltall i ArrLIC:ATION PROCESS No. SLOPED SYSTEM DESCRIPTION fn: Fastener type & sparing: Cap Sheet: Roof Covering: Drip edge: TILE CALCULATIONS Mr t ' Mri = M rs : PCA: PCA: PCA: ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals LUED ROOFING INDUSTRIES, INC. 050 N.W. 42nd Street - Miami, FL 33166 'hone: '(305) 477-7810 Fax (305) 594-9912 .0085 - 8arty Univenr - Thompson Burtgjob Legend Pitch Description • Drawing Report RC36 - Main (V.E.) Contract ,,,.„.PION, <none> Koppers 420-4 <none> Wall Flashing # 182 M T (4) <none> Gravel Stop / Flashing (8) <none> Equipment Flashing (9) <none> NC Curb Flashing (10) THE EDGE ................... .. • .................. 33,436.56 SF 2,015.48 536.58 1,478.42 32.58 15.67 l ualuay, Uat.a111ua1 44, 1070 11:39 AM Page 1 RFDATAW LF EA METRO- APPROYIED: 12/30197 METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING P OD C' ' CONTROL NOT ICE OF ACCEPTANC Koppers Industries. Inc. 436 Seventh Ave Pittsburg. PA 15219-1800 Your application for Product Approval of Koppers Built --Up Roofing Products over Concrete Decks under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely d crt - bed in the plans, specifications and calculations as submitted by: Factory AlutualResearch Corporation, Underwriters Laboratories, Into lynateelu Rngineerbrg Corp, and Exterior Research & Design, LLC. has been rccoaunendcd for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 to 17 and the standard conditions an page 18. This approval shall not be valid after the expiration date stated below. This' Building Code Compliance Office reserves the right to secure this product or material at any tfmc from a jobslte or manuf'acturer's plant for quality control testing. If this product or material fails to perform In the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Cade. The expense of such testing will be Incurred by the manufacturer. ACCEPTANCE NO.: 97- 1120.01 Revises No.: 964172.03 EXPIRES: la00 /0f aul Rodriguez Product Control Supervisor THIS IS THE COYERSHEET ADDITI PACES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Ftoridn under the conditions set forth above. 1 interne! mail address: postmaster ebuiloingcodeoniine.com Nomepage: hrtp://www.buildIngcodeonlitie.com m a U 4 Z 1O a 6861'T99CT8 YV;3 9C: Z1 l�ll15 96/80/Z0 • BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 M1AMi. FLORIDA 33130 -1563 (3D5) 275 -2901 FAX (305) 375 -2905 PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6339 Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County KOPPERS INDUSTRIES, INC. ACCEPTANCE NO.: 97- 1120.03 Applicant: Koppers Industries, Inc. 436 Seventh Avenue Pittsburg, PA 15219 -1800 ca tenory: Membrane Roofing System Sub -Catot ory: Built-Up Roofing Type: Coal Tar Pitch Sub - Tune: Fiberglass, Polyester /Organic Deck Type: Concrete ROOFING SYSTEM APPROVAL Product Control No.: 97- 1120.01 Approval Date: ece r 30, 1997 Expiration Date: December 30 2000 $ ystem Description Koppers Industries, Inc. manufactures coal tar pitch and coal tar bitumen built-up roof assemblies which are applied over insulated or uninsulatcd substrates. Coal tar systems may be applied over dead flat or very minor slope applications. All coal tar systems require surfacing of gravel or slag. Koppers Industries, Inc. has been supplying coal tar pitch and bitumen products to the roofing industry for better than fifty years. Coal tar pitch roof systems have some unique qualities due to the low softening point of the matsrial. Coal tar pitch built -up systems may be constructed of organic tarred felts, standard fiberglass felts or coal tar impregnated fiberglass felts. Contact: Frank Moore 436 Seventh Avenue Pittsburg, PA 15219 -1800 (412) 227 —2421/227-2002 Page 2of18 II O Z u 0 D Zuloaga Roofing Product Control Examiner 69617T99CT9 %v3 6C :ZZ NBS 96/90/Z0 Insulation Tpeq: Maximum F' t assifica Material Classification Concrete Class 'A' KOPPERS INDUSTfRIES, INC. ACCEPTANCE NO.: 97- 1120.0I Rockwool Regular/High Density Wood fiber Fibrous glass Perlite Potyisocyanurate Composite Board Maximum Design Pressure M rig] Design Pressure Concrete -317.5 psf 1' Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck types. Review system listings for design pressures and the Underwriters Laboratories Roofing Materials Directory for Fire Classitieations. Page 3 of 18 u0'Iu0D Frank Zuloaga Roofing Product Control Examiner 8881'T99CT8 %V3 BC :ZZ tIfRS 88/80/ZO 200 1pl KOPPERS INDUSTRIES, INC. TRADE NAMES OF PRODuers MANUFACTURED OR LABELED BY APPLICANT radnct Dim ---$' — Coal Tar Bitumen Available in 20 or 5S gallon drums or in bulk. Coal Tar Pitch Glass Fiber Base Sheet Kop -R (WC) Kop -R (WI) Kop -R (WII) Koppers Polyester Roofing Felt Available in 20 or S5 gallon drums or in bulk. Roll size; 36" x 108' various various various Kop-R High Density various Wood Fiber 8 sq./roll No. 15 Tarred Felt Ply Roil size: 36" x Sheet 144' Tar -Glas Ply Sheet Roll Size: 36 "x 108' Test Specification ASTM D 450 type III ASTM D 450 type I AST141 D-4601 PA 110 PA 110 PA 110 PA 110 Proprietary ASTM D 227 Organic Base Sheet Roll size_ 36" s ASTM D 2626 75' ASTM D 4990 'Tar -01as Premium Pty Roll size: 36" x ASTM D 4990 Sheet 108' Page 4of18 II0'IU ACCEPTANCE NO.: 97- I120.01 Product ,lscriptiort Coal tar pitch used as o waterproof and adhesive material in conjuction with organic or inorganic felts. Coal tar pitch used as a waterproof and adhesive material in conjuction with organic or inorganic felts. Non - perforated, type II asphalt Impregnated and coated glass fiber base sheet for use in conventional and modified bitumen built-up roofing. Polyisocyanurate and perlite composite Insulation board. Polyisocyanurate foam insulation. Polyisocyanurate foam insulation board. Wood fiber insulation board_ Spunband polyester plysbeet for use in conventional built -up roofing. Organic fiber based felt saturated with refined coal tar. Non - perforated, organic fiber based felt saturated and coated with asphalt surfaced with a parting agent. A coal tar impregnated and coated glass fiber ply sheet for use in conventional built-up roofing. A coal tar itnpercgnated and coated glass fiber ply sheet for use in conventional bitumen built -up roofing. r oaga Roofing Product Control Examiner 69617T99CT9 TVd 6C :ZZ NI1S 96/00/Z0 Pyrox KOPPERS INDUSTRIES, INC. TRAM'. NAMES OF PRODUCTS Test Product Dimensions Specification ACF am II various PA 110 E'NRG °Y -2, PSI - 25 I IyT berm AP E'NRG'Y -2 Plus ACFoant Composite Fiberglass Perlite Insulation various various various various Various various various High Density Wood various Fiberboard DeWest Fawner Roofgrip Fastener Olympic HD Olympic CD-I0 Olympic Fluted Nail HD Insulfixx Fastener Tru-Fast Fastener Asphalt Primer Coal Tar Priming Oil 9OOIj PA 110 PA 110 PA 110 PA 110 PA I i PA 110 PA 110 PA 110 PA 114 PA114 PA 114 PA 1I4 PA 114 PA 114 PA 114 ASTMD4I ASTM D 43 Page 5 of 18 1VIANUFACTURED BY OTHERS Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate composite insulation Polyisocyanurate composite insulation Fiberglass roof insulation Perlite insulation board Wood fiber insulation board Insulation fastening assembly with steel and plastic stress plate. Insulation fastening assembly with steel and plastic stress plate. Insulation fastener Insulation fastener Insulation fastener Insulation fastening assembly with steel and plastic stress plate. Insulation fastening assembly with steel and plastic stress plate. Asphalt Primer Coal tar based primer ACCEPTANCE NO.: 97- 1130.01 Manufacturer Atlas (with current NOA) Johns Manville (with current NOA) Celotex (with current NOA) Apache (with current NOA) Johns Manville (with current NOA) Atlas (with current NOA) Sce Approved Systems Listings Sce Approved Systems Listings See Approved Systems Listings Construction Fasteners, Inc. (with current NOA) ITW Buildcx (with current NOA) Olympic (with current NOA) Olympic (with current NOA) Olympic (with current NOA) SFS Stadler (with current NOA) Tru -fast (with current NOA) generic generic ran Zuloaga Roofing Product Control Examiner u 0 I u 0 D 6866T998T9 rid 8v :ZZ N11S 88/80/ZO KOP'PERS INDUSTRIES, INC. ACCEPTANCE NO.: 97-1120.01 SYSTEMS System Type A: Anchor sheet optional; all layers of insulation adhered to anchor sheet or primed deck with approved bitumen. Deck Type 31: Concrete Decks, Insulated, New Construction Deck Description: 2300 psi structural concrete or concrete plank All General and System Limitations shall apply. Insulation Fastener Fastening Fasteners Fastener Base Laver Tvpe Detail No Per Board Density One or more layers of the fallowing: Approved Type(s):1{op-R(WII), AC -Foam II, Pyrox, flyTheruu AP Minimum: 1.0" x 4' x 4' N/A N/A N/A N/A Approved Type(s): E'NRG'Y 2, PSX -25 Minimum: 1.0" x 3' x 4' N/A N/A N/A N/A Approved Type(s): E'NRG'Y 2 Plus, Kop-R Composite, Kop- R(WC), ACFoam Composite Minimum: 1.5" x 3' x 4' N/A N/A N/A N/A Approved Type(s): Standard or Wide Flute Armor -R Glass, Fiberglas Roof Insulation or Fiber Glass Roof Insulation Minimum: 15/16" x 4' x 4' N/A N/A N/A N/A Approved Type(s): Kop-R Wood Fiber, Armor Board Regular or High Density Fiberboard, Esgard Fiberboard, Celotex Regular or 'Ugh Density Fiberboard, Traffic Top, High Density Roof Fiberboard, GAFTEMP Regular or High Density Fiberboard, Huebert Fiberboard Minimum: fZ" x 2' x 4' N/A N/A N/A N/A Insulation Fastener Fastening Fasteners Fastener Ton Laver T ;se Detail No. Per urd Density One or more layers of the following: Approved Type(s): E'NRG'Y 2 Plus, Kop -R Composite, Kop- R(WC), ACFoam Composite Minimum: 1.5" x 3' x 4' N/A N/A N/A N/A Approved Type(s): Standard or Wide Flute Armor - Glass, Fiberglas Roof Insulation or Fiber Glass Roof Insulation Minimum: 15/16" x 4' x 4' N/A N/A N/A N/A Approved Type(s): Kop-R Wood Fiber, Armor Board Regular or High Density Fiberboard, Esgard Fiberboard, Celotex Regular or High Density Fiberboard, Traffic Top, Hrgh Density Roof Fiberboard, GAFTEMP Regular or High Density Fiberboard, Huebert Fiberboard Minimum: 'f." x 2' x 4' N/A NIA NIA Approved Type(s): Cclotherm, ConPerl, GAFTEMP Permalite, Fesco Minimum: W' x 2' x 4' N/A N/A Page 7 of l II 8000 0 N/A c �tt oaga Roofing Product Control Examiner U 0 1 u 0 3 6981'T99t:T8 XV3 oT:zz AZAs 86/90/Z0 KOPPERS INDUSTRIES, INC. ACCEPTANCE NO.: 97- I120.01 Note: M7hcn using hat asphalt concrete deck shall be printed with ASTM D 41 asphalt primer and allowed to dry prior to application of vapor barrier or insulation. All insulation shall be adhered to the vapor barrier or primed deck in full moppings of approved asphalt or and tar pitch within the EVT range and at a rate of 20-40 lbs. /sq. Please refer to Metro-Dade County Roofing Application Standard PA 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top Layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Anchor Sheet: Base Sheet Ply Sheet: Cap Sheet Surfacing: Maximum Design Pressure: Maximum Fire Classification: Maxintutn Slope: 6000 (Optional) One ply of Organic Base Sheet or Glass Fiber Base Sheet or one or two plies of Glass Fiber Felt, Tar -Glas, Tar -Glas Premium, No. 15 Tarred Felt or Polyester Roofing Felt applied in hot asphalt, coal tar pitch or coal tar bitumen at 25 lbs./sq. per ply. (Optional) Koppers organic or glass fiber base sheet adhered to the insulation substrate with approved bitumen at an application rate of 25 Ibs./sq. t 15 %. Two, or more plies of Koppers Tarred Felt, Glass Felt, Tar -Glas, Premium Tar - Glas or Polyester Roofing Felt. Roof covet may be Glass Fiber Felt, Tar -Glas or Premium Tar -Gins Felt adhered in a full mopping of approved coal tar at an application rate of 25 Ibs - /sq. ± 15%. None. Flood coat of coal tar with an application rate of 701bsisq.; plus gravel or slag at application rates of 400 and 300 Ibssq., respectively. -317.5 psf (for min. L3" Approved polyisocyanurate with m in. %" Kop -R High Density Fiberboard eoverboard in hot asphalt.) -2123 psf (for min. 1.3" Approved polyisocyanurate with min.' /" GAFfEMP Permalitc in hot asphalt) -140.0 psf (for min. I.5" thick Approved composite board or min. 1a" Approved poiyisocyanurate with min. %" Structodek coverboard in hot asphalt.) -100.0 psf (for mitt. 1_3" Approved polyisocyanuratc with min.' /" Johns Manville Fesco Board in hot asphalt) - 45.0 psf Far ail other applications, (See General Limitation #20.) 'A'. See General Limitation # 2. See General Limitation #3_ Page 8ofl8 Prank Za ?gags Roofing Product Control Examiner u 01110 D 6866T99CT8 rid OV :ZZ .rns 96/90/ZO }COPPERS INDUSTRIES, INC. Test Anency/ Factory Mutual Research d_I. 1 WSAI.AM Corporation Factory Mutual Research FM Approval Guide Corporation Underwriters Laboratories, Inc. Dynatech Engineering Dynatech Engineering Dynatech Engineering Dynatech Engineering Dynatech Engineering Exterior Research 8c Design, LLC. L00M UL Roofing Materials and Systems Directory 1.94.17 4301 - 12.941 4301- 12.94 -.2 4302 - 1.95 -2 4302- 1.95 -4- 43 ©2.02.9 - 1 Namg TEST REPORTS P a g e 6of1it ACCEPTANCE NO.: 97 1130.01 Rcpgrt Date I -90 Wind Classification 08/12/93 insulation attachment Published Annually requirements Fire Classifications Published Annually Wind Uplift, Small Scale 01/17/94 Wind Uplift 12/05/94 Wind Uplift 12105/94 Wind Uplift 01 /03/95 Wind Uplift 01/04/95 PA 114(D) 02/15/97 Frank Zulonga Roofing Product Control Examiner U 0 1 u 0 3 6g81'T99VT9 %Vd 077 :EZ MRS 86/$0/EO ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU) — Continued 2. Deck: C -15/32 Incline: 3 (See Note) Insulation: : " SOFoam" (EPS), any thickness, field covered with 1 in. min perlite. Ply Sheet 3 to 5 plies Type 15, G1 or G2. Surfadng: Gravel or Type G3 mineral surfaced cap sheet. Note: Incline i s reduced to 1 in. when Type G3 mineral surfaced cap sheet is used as the surfacing. SINGLE PLY MEMBRANE SYSTEMS Class A - Ballasted Unless otherwise indicated, insulation may be loose laid or mechanical) fastened; membrane may be loose laid, mechanically fastened or adhered in place. 1. Deck: C -15/32 Incline: 2 Insulation:: " SOFoam" (EPS), any thickness, field covered with min 3/4 in. perlite, any thickness of EPS. Membrane: Any UL Classified membrane. Surfadng: River bottom stone (3/4 to 1 -1/2 in. diam) , 1000 lb /sq. 2. Deck: NC Incline: 2 Note: Deck must be one of the following: A.) Monolithic poured cementitious deck. B.) steel covered with gypsum board or perlite board, 1/2 in. min. C.) Structural decks with all joints covered with Type 30 base sheet, extending 6 in. (min) on each side of joint. D.) Metal deck covered with cellular concrete, gypsum concrete, vermiculite concrete or perlite concrete. Insulation: : " SOFoam" (EPS), any thickness, field covered with 1 in. min wood fiber or perlite. Membrane: Any UL Classified membrane. Surfadng: River bottom stone (3/4 to 1 -1/2 in. diam) , 1000 lb /sq. Class A, B or C (See Note) - Fully Adhered Unless otherwise indicated, insulation is mechanically fastened in place. 1. Deck: NC Incline: See Note Insulation: : "SOFoam" (EPS), any thickness, field covered with 1/2 in. min perlite or wood fiber. Membrane: Any UL Classified modified bitumen suitable for use with any roof insulation. Surfadng: See Note. Note: Classification (A, B or C) will be the same as that for the original insulation /membrane roofing system. Max incline and surfacing shall be in accordance with the classification established for the insulation /membrane roofing system. Base sheet (if any) shall be in accordance with the classi- fication established for the insulation/ membrane roofing system. 2. Deck: NC Incline: See Note Insulation: : " SOFoam" (EPS), any thickness, field covered with 1 in. min wood fiber or perlite. Membrane: Any UL Classified EPDM, CPE, CSPE, PVC, CR, NBP or PIB membrane, suitable for use with any roof insulation. Surfadng: See Note. Note: Classification (A, B or C) will be the same as that for the original insulation /membrane roofing system. Max incline, attachment of membrane and surfacing of membrane shall be in accordance with the classification established for the insulation /membrane roofing system. Class A, B or C (See Note) - Mechanically Fastened 1. Deck: NC Incline: See Note Insulation: : "SOFoam" (EPS), any thickness, field covered with min 1 in. thick perlite or wood fiber. Membrane: Any UL Classified EPDM, CPE, CSPE, PVC, CR, NBP or PIB membrane, suitable for use with any roof insulation. Surfadng: See Note. Note: Classification (A, B or C) will be the same as that for the original insulation /membrane roofing system. Max incline, attachment of membrane and surfacing of membrane shall be in accordance with the classification established for the insulation /membrane roofing system. KOCH MATERIALS CO PO BOX 2338, WICHITA KS 67201 ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Class A, B and C Hot roofing asphalt for use with organic asbestos and glass felts. R13166 (N) KOOL SEAL INC R12209 (N) 1499 ENTERPRISE PKY, TWINSBURG OH 44087 MAINTENANCE AND REPAIR Class A 1. Deck: NC Incline: 2 - 1/2 Existing Roof System: Class A, B or C BUR (gravel may be removed) covered with: Base Coat: "Kool Seal" or "Uniflex" Elastomeric White, Gray or Black roof coating. 2 gal /sq. Surfacing: "Kool Seal" or "Uniflex" Elastomeric White, Gray or Black roof coating, 1 gal /sq. coat. KOPPERS INDUSTRIES INC 436 7TH AVE, PITTSBURGH PA 1 ASPHALT FELT LOOK FOR MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) 227 ROOFING SYSTEMS (TGFU) — Continued 2. Deck: NC Incline: 1/2 Existing Roof System: Class A, B or C BUR (gravel may be removed) covered with: Su � ex 500 Aluminum Roof Coating" at 1 -1/2 R927 (N) 19 HOT ROOFING ASPHALT Class A, B and C roofing systems. Type 61 asphalt glass fiber felt, "Koppers Glass Fiber Roofing Felt", for use with hot roofing asphalt in Class A and B roofing systems. Class A 1. Deck: NC Incline: 3 Insulation: "KOP -R (WTI) Roof Insulation" or "KOP -R (WC) Composite Roof Insulation" or KOP -R (WT) Tapered Roof Insulation or any UL Classified insulation, any thickness, hot mopped or mechanically fastened. Surfadng: Class A gravel surfaced asphalt organic felt or asphalt glass fiber felt roofing systems, hot mopped to insulation with hot roofing asphalt. 2. Deck: C -15/32 Incline: 3 Insulation (Optional): "Kop -R Roof Insulation ", 3/4 in. min, mechanically fastened or hot mopped. Base Sheet Type G2 "Glass Fiber Base Sheet", nailed or hot mopped. Ply Sheet Min 2 plies Type Gi "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI ", hot mopped. Surfadng: Gravel or slag. 3 Deck: C -15/32 Incline: 3 Insulation (Optional): Wood fiber, 1 in. min, "Kop -R Composite Roof Insulation" or "Kop -R Roof Insulation ", mechanically fastened or hot mopped. Ply Sheet Min 2 plies Type G1 "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI ", hot mopped. Surfadng: Gravel or slag. 4 Deck: C -15/32 Incline: 3 Insulation (Optional): "Kop -R Composite Roof Insulation" or °Kop -R Roof Insulation ", mechanically fastened or hot mopped. Base Sheet Type G2 "Glass Fiber Base Sheet" or "Vented GB Base Sheet", nailed or hot mopped. Ply Sheet Min 3 plies Type 15 perforated asphalt organic felt, hot mopped. Surfadng: Gravel or stag. 5 Deck: C -15/32 Incline: 3 Insulation (Optional): "Kop - Composite Roof Insulation ", "Kop -R Roof Insulation ", 3/4 in. min, mechanically fastened or hot mopped. Base Sheet Type 15 asphalt organic felt or Type G2 "Glass Fiber Base Sheet" or "Vented GB Base Sheet", nailed or hot mopped. Ply Sheets: Min 3 plies Type 15 perforated asphalt organic felt, hot mopped. Surfadng: Gravel or slag. 6 Deck: NC Incline: 2 Insulation (Optional): Wood fiber, "Kop -R Composite Roof Insulation ", "Kop -R Roof Insulation ", glass fiber or perlite, mechanically fastened or hot mopped. Base Sheet Type G2 "Glass Fiber Base Sheet", nailed or hot mopped. Ply Sheets: Min 1 ply Type G1 "Glass Fiber Felt", hot mopped. Surfadng: Type G3 cap sheet Celotex Corp. "Leto -Glass Cap Sheet", hot mopped. 7 Deck: C -15/32 Incline: 1/2 Insulation (Optional): "Kop - Composite Roof Insulation ", "Kop -R Roof Insulation ", glass fiber or perlite, 3/4 in. min, mechanically fastened or hot mopped. Min 1 in. wood fiber is suitable on noncombustible decks. Base Sheet Type G2 "Glass Fiber Base Sheet", nailed or hot mopped. Ply Sheet: Min 2 plies Type G1 "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI ", hot mopped. Surfadng: Type G3 cap sheet Celotex Corp. "Celo -Glass Cap Sheet", hot mopped. 8 Deck: NC Incline: 2 Insulation (optional): Wood fiber, "Kop -R Composite Roof Insulation ", "Kop -R Roof Insulation ", glass fiber or perlite, 3/4 in. min, hot mopped. Ply Sheets: Min 3 plies Type Gi "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI", hot mopped. Surfacing: Type G3 cap sheet Celotex Corp. Celo -Glass Cap Sheet", hot mopped. 9 Deck: C -15/32 Incline: 1/2 Insulation (Optional): "Kop -R Composite Roof Insulation ", "Kop -R Roof Insulation ", glass fiber or perlite, 3/4 in. min, mechanically fastened. Ply Sheets: Min 3 plies Type G1 "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI ", hot mopped. Surfacing: Type G3 cap sheet Celotex Corp. "Celo -Glass Cap Sheet" hot mopped. , ?2ti ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU)— Continued 10. Deck: NC • Incline: 1/4 Insulation (Optional): One or more layers "Kop -R Composite Roof Insulation ", Kop -R Roof Insulation ", glass fiber or perlite, mechanically fastened or hot mopped. Base Sheet Type G2 "Glass Fiber Base Sheet", nailed or hot mopped. Ply Sheets: Min two plies Type Gi "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI ". Surfacing: Two applications Celotex Corp. "FR Bright'N White ", 0.75 gal/sq/coat. 11. Deck: NC Incline: 1/4 Insulation (Optional): "Kop -R Composite Roof Insulation ", "Kop -R Roof Insulation" or perlite, mechanically fastened or hot mopped. Ply heets: Three or four plies Type G1 "Glass Fiber Felt', "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI". Surfacing: Two coats Celotex "FR Bright 'N White ", 0.75 gat/sq/coat. 12. Deck: NC Incline: 3 Insulation: "Kop -R Roof Insulation ". One or more layers, any thickness, mechanically fastened or adhered with hot roofing asphalt. Surfacing: Any Class A or B roofing system composed of asphalt organic felts, glass felts or coal tar felts which are surfaced with gravel, crushed stone or crushed slag. 13. Deck: C -15/32 Incline: 1/2 Insulation: Foamed plastic, "Kop -R Roof Insulation ", "Kop -R Composite Roof Insulation ", "Kop -R Tapered Roof Insulation ", 4.1 in. max, sprinkle mopped to deck. Covering: Class A asphalt organic felt or asphalt glass fiber felt roofing system hot mopped to insulation. 14. Deck: NC Incline: 1/4 Insulation (Optional): Celotex Corp. "Hy -Therm AP", " Thermax EL V", Hy -Therm COMPOSITE Roof Insulation, Thermax "Hy- Tec -2 ", "Hy -Tec" ( "Energy- Lok"), " Thermax EL IV", Thermax "Hy -Tec Plus -2", " Thermax TRI- Star", "Hy -Therm STABLE -R" or perlite, mechanically fastened or hot mopped. Ply Sheets: Three or four plies Type G3 "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI ". Surfacing: Two applications Celotex Corp. "FR Bright 'N White ", 0.75 gal/sq/coat. 15. Deck: NC Incline: 1 -1/2 Insulation (Optional): Wood fiber, 1 in. min, Celotex Corp. "Thermax Hy -Tec Plus -2 ", 4.0 in. max, glass fiber or perlite, 3/4 in. min, mechanically fastened or hot mopped. Ply Sheets: Min three plies Type G1 "Glass Fiber Felt', "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI ", hot mopped. Surfacing: Two applications of Celotex Corp. "Bright 'N White FR" roof coating applied at a rate of 0.75 gat/100 ft/sq per coat. COAL TAR FELT SYSTEMS WITH HOT ROOFING COAL TAR PITCH Class A 1 Deck: C 15/32 Incline 3. Insulation: "KOP -R (WWII) Roof Insulation" or "KOP -R (WC) Composite Roof Insulation" or "KOP-R (WT) Tapered Roof Insulation or any UL Classified insulation, any thickness, hot mopped or mechanically fastened. Ply sheets: 4 plies Type G1 "TAR-GLAS" or "Premium TAR -GLAS" or "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI" or "Koppers Coal Tar Organic Felt", hot mopped with Koppers coal tar bitumen. Surfacing: Gravel, crushed stone or slag embedded in a flood coat or Koppers coal tar bitumen. 2. Deck: C -15/32 Incline: 1/2 Insulation Optional): Wood fiber, 1 in. min, "Kop -R Composite Roof Insulation ", Kop -R Roof Insulation ", glass fiber or perlite, 3/4 in. min, mechanically fastened or hot mopped. Base Sheet Type G2 "Glass Fiber Base Sheet", nailed or hot mopped. Ply Sheets: Min 2 plies Type Gi "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI ", hot mopped. Surfacing: Gravel or slag. 3. Deck: C -15/32 Incline: 1/2 Insulation Optional): Wood fiber, 1 in. min, "Kop -R Composite Roof Insulation ", Kop -R Roof Insulation ", glass fiber or perlite, 3/4 in. min, mechanically fastened or,hot mopped. Ply Sheets: Min 3 plies Type G1 "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI ", hot mopped. Surfacing: Gravel or slag. 4. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Wood fiber, 1 in. min, Celotex Corp. "Hy -Therm AP", " Thermax EL V", Hy-Therm COMPOSITE Roof Insulation, "Thermax Hy -Tec Plus -2 ", EL IV", " Thermax TRI- Star", "Hy -Therm STABLE -R ", glass fiber or perlite, 3/4 in. min, mechanically fastened or hot mopped. Ply Sheet Min 3 plies Type G1 "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type P1" or "Glass Fiber Roofing Felt, Type VI ", hot mopped. LOOK FOR MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU)— Continued Surfacing: Gravel or slag. 5. Deck: C -15/32 Incline: 1 Base Sheet Required for combustible decks - "TAR -GLAS" or "Premium TAR -GLAS" nailed. Ply Sheet Two or more plies coal tar organic felt, "TAR-GLAS" or "Premium Tar- Glas", hot mopped with coal tar pitch or bitumen, 25 lb /sq. Insulation: Dow Chemical Company "Styrofoam RM, PD or Styrorib" (plastic) 1 in. min, with or without attachment. Scrim: (Optional) "Fabrene ", "International Paper D689" or "Rufon Polypropylene ", 2 oz /sq yd. Surfacing: Crushed stone, river bottom stone, (3/4 to 1 -3/4 in. diam) 900 lb /sq, concrete blocks 10 lb /sq min, spread not more than 1/8 in. apart or Dow Chemical Company Styrofoam "Lightguard" panels surfaced with 5/16 in. min concrete mortar, butted together. COMBINATION HOT AND COLD SYSTEMS Unless otherwise indicated, all moppings are with hot roofing asphalt. Class A 1. Deck: NC Incline: 1 Insulation (Optional): Wood fiber, "Kop -R Roof Insulation ", "Kop -R Composite Roof Insulation ", glass fiber or perlite, mechanically fastened or hot mopped. Base Sheet: Type 15 "Organic Base Sheet", nailed or hot mopped. Ply Sheets: Min 2 plies Type G1 "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI", hot mopped. Surfacing: Cold application coating Celotex Corp. "Flat -Topp Emulsion" at 3 gal/sq or "Celotex Fibrated Aluminum Roof Coating" at 1.2 gat/sq. 2. Deck: NC Incline: 1 Insulation (Optional): Wood fiber, "Kop -R Composite Roof Insulation ", "Kop -R Roof Insulation ", mechanically fastened or hot mopped. Ply Sheets: Min 4 plies Type G1 "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type Ti" or "Glass Fiber Roofing Felt, Type VI", hot mopped. Surfacing: Cold application coating Celotex Corp. "Flat -Topp Emulsion° at 3 gal/sq or "Celotex Fibrated Aluminum Roof Coating" at 1.2 gal/sq. 3. Deck: NC Incline: 1 Insulation (Optional): "Kop -R Composite Roof Insulation ", "Kop -R Roof Insulation ", mechanically fastened or hot mopped. Base Sheet: Type G2 "Glass Fiber Base Sheet", mechanically fastened or hot mopped to insulation or deck. Ply Sheets: Three plies of Type G1 "Glass Fiber Felt", hot mopped. Surfacing: Cold application coating Celotex Corp. "Flat -Topp Emulsion" at 2.5 gal/sq. 4. Deck: NC Incline: 1/2 Insulation (Optional): "Kop -R Composite Roof Insulation ", "Kop -R Roof Insulation ", mechanically fastened or hot mopped. Base Sheet Type G2 "Glass Fiber Base Sheet", mechanically fastened or hot mopped. Ply Sheets: Three plies of Type G1 "Glass Fiber Felt", "Glass Fiber Roofing Felt, Type IV" or "Glass Fiber Roofing Felt, Type VI", hot mopped. Surfadng: Cold application coating Cetotex Corp. " Fibrated Aluminum Roof Coating" at 1.2 gat/sq. SINGLE PLY MEMBRANE ROOFING SYSTEMS Class A - Ballasted 1. Deck: C -15/32 Incline: 2 Membrane: "2040 -M ", "2040 -S" or "2050 -S" (modified bitumen), laid loosely. Surfacing: River bottom stone (1/2 to 2 -1/2 in. diameter) at 1000 (bs /sq. 2. Deck: NC Incline: 2 Base Sheet (Optional): Type 15, Type G -1 or G -2, hot mopped. Insulation: Polyisocyanurate, urethane, perlite /urethane composite, perlite /polyisocyanurate composite, glass fiber, perlite or wood fiber, 1.4 in. max. Base Sheet Type 15 or G2, mechanically fastened. Membrane: "2040 -M ", "2040 -S" or "2050 -S" (modified bitumen), heat fused. Surfacing: Gravel, applied loosely. 3. Deck: NC Incline: 2 Insulation (Optional): Any UL Classified (except polystyrene), any thickness. Base Sheet Type 15, Type G -1 or G -2, or vented base sheet mechanically fastened or hot mopped. Membrane: "2040 -M ", "2040 -S ", "2041 -M ", "2041 -S ", "2045 -M" or "2050 -S ", heat fused or hot mopped in place. Surfadn • Gravel, laid loosely or embedded in hot roofing asphalt or any UL Classified emulsion. Emulsion applied at 4 -5 gat/sq• 4. Deck: C -15/32 Incline: 2 Insulation: "Kop -R Composite Roof Insulation ", 1 -1/2 to 4 in., laid loosely, 1/2 to 2 in. wood fiber is suitable on noncombustible decks. Membrane: "Celotex Ceto -1 Roofing Membrane ", 45 mil (EPDM), or "Cetotex Celo -1 FR Roofing Membrane ", 60 mil (EPDM), laid loosely. Surfacing: River bottom stone, 3/4 to 1 -1/2 in. diam, at 1000 lbs /sq. Underwriters laboratories Inc. January 19, 1999 Allied Roofing Industries Ed Cardozo 7050 N. W. 4?' Street Miami, FL 33166 Dear Mr. Cardozo: This is to confirm our telephone discussion regarding the abbreviations and terms used in Classified Roofing Systems. A copy of the explanation of these terms as it appears in the Guide Information preceding the Roofing Systems category is attached. With respect to the roof deck description the reference to noncombustible (NC) limits that system only to noncombustible decks. The reference to combustible (C) with a suffix related to minimum thickness of the combustible deck also indicates it is suitable for use over noncombustible deck. If there is need for further clarification, please contact me. Very truly yours, Kenneth Rhodes Associate Managing Engineer Engineering Services, Dept. 3011 333 Pfingsten Road Northbrook. Illinois 60062 -209 United States Country Code (1) (847) 272 -8800 FAX No. (847) 272 -8129 hip. / /www.ul.com lf� a centari 0"i � public safety "" est. 1 394 rov r- profit crgarnzaticr .Heated to public safety :Ir •-mr , ;T to quality s; ^ /'C_ • 10 ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU) — Continued cement and surfaced with a cold application coating. See individual Classifi- cations for designations and application rates for cements and coatings. Unless otherwise required, granules or sand may be optionally applied to any coating. COMBINATION HOT AND COLD SYSTEMS These roofing systems are composed of asphalt saturated organic felts or asphalt coated glass fiber felts applied with hot roofing asphalt and surfaced with cold application coatings. Some systems are surfaced with mineral surfacings, such as sand or No. 11 roofing granules, which are embedded in the coating. Unless otherwise required, granules or sand may be optionally applied to any coating. See individual Classifications for designations and application rates for coatings and surfacing materials. FLUID APPLIED COATING SYSTEMS These roofing systems are composed of a number of layers or coats of plastic roof coatings. Adequate drying time is allowed between successive layers or coats to form a protective membrane. Some systems may utilize various types of reinforcing filaments embedded in a coating layer while wet. Also, some ms may utilize surfacing materials. See individual Classifications for esignations and application rates for coatings and surfacing materials. MAINTENANCE AND REPAIR SYSTEMS These roofing systems are composed of various types of roofing applications which are specifically limited for installation (recover) over existing roofing systems as specified. These systems may not meet Classification requiremen without being used over existing systems. Recovering may also be accomplis with Classified new construction roofing systems where compatibility has " en determined by test, by empirical data or by known performance prope . of similar matenals to the test methods. The following guidelines are pro '•ed to assist authorities having jurisdiction in determining the suitability o a new construction Roofing System as a recover system. NONCOMBUSTIBLE DECK CONSTRUCTION: 1. Insulated roof systems may be utilized over any type of exi : ng roof system and maintain its new construction rating when the ro deck is noncombustible. 2. Insulated multiple layered hot mopped, cold application or odified bitumen membrane new construction systems with a base ply o Type G1 or Type G2 may be used over any existing roof system amd mai tain its new construction rating when the roof deck is noncombusti e. The insulation may be omitted from the recover system. 3. Uninsulated multiple layered hot mopped, cold application or modified bitumen membrane new construction systems with a base ply of Typ G1 or Type G2 may be used over any existing uninsulated roof system - d maintain its new construction rating when the roof deck is noncom bustible. 4. Spray applied foam systems with minimum 1 -1/2 in. thick foam may be used over any existing roof system and maintain its new construction rating when the roof deck is noncombustible. COMBUSTIBLE DECK CONSTRUCTION: 1. Insulated roof systems Classified for use over combustible deck can be used over any type of existing roof system and maintain its new construction rating. 2. Insulated roof systems Classified for use over noncombustible deck may be used over any type of Class A, B or C existing roof systems. The resultant Class will be the lesser rating of the existing system or the new construction (recover) system. 3. Uninsulated multiple layered hot mopped, cold application or modified bitumen membrane new construction systems with a base ply of Type G1 or Type G2 may be used over any existing uninsulated roof system and maintain its new construction rating. 4. Spray applied foam systems with minimum 1 -1/2 in. thick foam Classified for use over noncombustible deck may be used over any type of Class A, B or C existing roof system. The resultant Class will be the lesser rating of the existing system or the new construction (recover) system. SINGLE PLY MEMBRANE SYSTEMS (INCLUDES MODIFIED BITUMEN MEMBRANES) These roofing systems are composed of various types of membranes (such as EPDM, PVC, CSPE and modified bitumen) which are either ballasted, fully adhered or mechanically attached. UL Classified insulation may be utilized, as well as various coatings, splicing adhesives, lap sealants and caulking materials. See individual Classifications for designations of products and application rates for various components. Unless otherwise required, granules or sand may be optionally applied to any coating. SPRAY APPLIED FOAM AND COATING SYSTEMS These roofing systems are composed of a foam, formed by the simultaneous spraying of two hquid components to a nominal thickness, covered with a cold application coating system to form a protective covering. Surfacing materials, such as sand or No. 11 roofing granules, may be embedded in the coating while wet. See individual Classifications for designation of products, foam thickness and application rates for the coatings involved. Unless otherwise required, granules or sand may be optionally applied to any coating. Where indicated in individual Classifications, specific systems have also been Classified for impact resistance in accordance with UL2218, "Impact Resistance of Prepared Roof Covering Materials". LOOK FOR MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU)— Continued The Classifications for impact resistance are expressed as Class 1, 2, 3 or 4, which relate to a system's ability to withstand impacts from 1 -1/4, 1 -1/2, 1 -3/4 and 2 in. diameter steel balls respectively. The acceptance criteria used for establishing the Classification is the system's ability to absorb these impacts without visible evidence of tearing, fracturing, cracking, splitting, rupture, crazing or other opening which would expose foam to the effects of weather. The effects of weathering prior to the impact resistance testing these systems have not been investigated. OTHER SYSTEMS These systems cover products such as building units used in specific Class A, B or C roofing systems. Building units may consist of composite insulation boards, metal faced insulation panels or insulating material, faced on top and bottom with metal or plastic reinforced glass fiber skins which are intended for direct application to rafters or purlins. The structural aspects of these materials have not been evaluated. See in r ividual Classifications for the specific system details. The basi ndards used to investigate products in tegory are ANSI - 90 "Tests For Fire Resistance of Roof Covering Materials". So of the ucts specified in these systems are covered in Standard UL 55A - "Ma 'als or Built -Up Roof Coverings" ABBREVIATIONS AND TERMS USED IN CLASSIFIED ROOFING SYSTEMS DESCRIBED FOR INDIVIDUAL MANUFACTURERS Decks - Noncombustible v NC; combustible (includes noncom- bustible a C. (Suffix number indicates the minimum thickness of plywood). Maximum incline in inches to the horizontal foot at Incline, "x" (in.). Inclines sufficient to permit drainage a Iodine - no limitation. Per 100 square feet a Per sq. Application rates for mineral surfadngs and liquid components shall be a number indicating either lbs or gals per square. Minimum surfadngs in a flood coat of hot roofing asphalt or coal tar pitch - 400 lbs gravel per square a gravel 400 lbs crushed stone per square a crushed stone 300 lbs slag per square a slag Application rates differing from the above are indicated in the individual Classifications. Any other surfacing materials used are described on individual Classifi- cations with type and application rates specified. LOOK FOR CLASSIFICATION MARKING ON PRODUCT Classification Marking of Underwriters Laboratories Inc. (shown below) on the "dle, package or container is the only method provided by derwriters Laboratorie o identify materials used in roofing syste ave been produced under its • tion and Foll Two methods of labeling are prove" - " for this material: (1) Each bundle, package, or container will bear the Classification Marking, (2) a Certificate is issued to the interested parties. This Certificate is prepared by the manufacturer for each construction site he supplies. The use of the Certificate is optional when each bundle, package, or container bears the Classification Marking but in all cases is restricted to material shipped directly from the manufacturer to a construction site. CEMENTS AND COATINGS FOR ROOFING SYSTEMS+ CLASSIFIED BY UNDERWRITERS LABORATORIES INC.® AS TO AN EXTERNAL FIRE EXPOSURE ONLY + - Or one of the following designations: 1. Type 15 Saturated Felt, Cap or Base /Ply Sheet For Roofing Systems. 2. Type 30 Saturated Felt, Cap or Base /Ply Sheet For Roofing Systems. 3. Type G1 Coated Base/Ply Sheet for Roofing Systems. 4. Type G2 Coated Cap or Base /Ply Sheet for Roofing Systems. 5. Type G3 Mineral Surfaced Base /Cap Sheet For Roofing Systems. 6. Mineral and Fiber Board for Roofing Systems. 7. Foamed Plastic for Roofing Systems. 8. Tiles for Roofing Systems. 9. Building Units for Roofing Systems. 10. Membrane for Roofing Systems. 11. Flashing Material For Roofing Systems. 12. Foamed Plastic Ingredient For Roofing Systems. 13. Base /Ply Sheet For Roofing Systems. 14. Slip Sheet For Roofing Systems. 15. Hold Down Device For Roofing Systems. 16. Membrane Splicing Tape For Roofing Systems. 17. Insulation Joint Tape For Roofing Systems. 18. Insulation Adhesive For Roofing Systems. As appropriate, the statement "Also Classified as to Impact Resistance (see Roofing Materials and Systems Directory)" may also be included. . .... ..... DeRose & Slopey CONSULTING ENGINEERS. MC. LAND PLANNING • CIVIL • STRUCTURAL ENVIRONMENT • ELECTRICAL • MECHANICAL 160 S. ANDREWS AVENUE SUITE 360 POMPANO BEACH, FLORIDA 33089 (305) 942-7703 c9 11641D r- e-e-1Pe ....... • • • • L4:1, r-s e7 Q cd' JOB SHEET NO OF CALCULATED BY d;75 DATE CHECKED BY DATE F1ZOX M o. C; , 4 SPO(06 1 SCALE woo FLAT-REG4104.31415 ate DEC 3 1qPRI. 14! O fef4 4 - ) 4 .-- 6r 410 — ?Z.-6 esie 1 THOMPSON FOR BUILDING BARRY UNIVERSITY V A r// W1r.1 ED l_ox>g='s !•l cacao 'w S /N CB 1-44-re-i4 Eu c X' }} Ak Tc, +t , FEe ZePs LPP L.1.1 Cn tLoo�tw (a 1JS ]�- Owt iR PROJECT Nur+em Fee Check Number no O IJ.W- 4 ck-Q • }- le.,. 4 L A2164, Other • " 8 1/25 WED 12:p tek auk37281.144 rL[uv nnrizn Florida Department of Environmental Protection State Asbestos Coordinator 2600 Blair Stone Road Tallahassee, Florida 3U99-2400 I. Facility Name �:L, _ . v v 5 ► • . � Address 113 0 D — Si L41 Air % g .102L 4 State L_ Tip 311G1 te _LDta + 2- • Surveyed by, Lr & - G i °aeo,1'm Butting size S3 7 (Square Feet) # of Floors 3 Age In Years Prior Use I. Fee Receipt Will Be Sent to Address in Block Below: (Print orType) - M. Facility Owner Phone Address t I S 2hg- City t-t t *rt t st -40'265 Stat4 . L. _.. •raw Cotttot'a Na t c _.. F - s Address 7O b N .w . 42 s-r2 r at ,-i,tktir t P h o n e ( 3or) All -1510 V. Demolition D NOTICE OF ASBESTOS REMOVAL PROJECT T or Notice: %Original ❑ Revised D Ca ceged. R E R i O O F ,3.f•7 Finish Date 3/3 /Pi VL REtio be1ounot4 PROCEDURES To BE Use) MUST OBTAIN NOR DD APPROVAL BERME Uri A Dm' MEIHCC1 K ve. Waste DiaPosd Ste Name Q 9 11 e •1 C • Addles VItL Fee Calculation &Type of RAON b Renovations or ACM in Demolitions RACK (cirdde Yes or No) Square Feet Surfadng Material Yes—No.— Upear Feet Pipe Yes._._. No... Square Feet C.ementitious Material Square Feet Reslieirt Roaring Feet Asphalt .. -Yes_ -No— "4" It; P dT quare RACM ( -. _ r feet) S — La '. !L �t • e) �' a,edk if Demolition only Yes ._No_ 3l "► • Rerrarra * Demolition with no ACM O Emergency O Demolition Start Date Metro -Dada DEMI Air Facilities Section 33 S.W. 2nd Avenue, Stole 9-223 Miami. Flocida•33130 -1540 zip 331 bl Annual D Class State 'L. 33 1ih6 Ronda Ucense No: (,L_ 4-o44too9 Finish Date X. Procedures for Unexpected RAGM Eon/TACT I FLAN REVIEW SECTION AIR REVIEW This is to certify that the required notification(s) regarding asbestos have been submitted in compliance with app lic Sic regulations ' 'E • P -12- BUILDER NAME: DATE OF TREAT ,4ENT: CHEMICAL: 1 L/ CHEMICAL: PEST CONTROL, INC. OTICE OF T E OTECTIVE TREATMENT As REQUIRED BY FLORIDA BUILDING CODE (FBC) 104.2.6 TIME OF TREATMENT: APPLICATOR: _ J � TREATMENT ADDRESS: /, /77/ (U r t- • JOB #: r � (3 JCQ *()' LOT: BLOCK: UNIT: SPRAY & TAMP SPRAY ONLY SPRAY # I RESIDENTIAL COMMERCIAL ADDITION % N3(C) GALLONS MONOLITHICC S/F STEMWALL SF L/F L/F DATE OF TREATMENT: TIME OF TREATMENT: APPLICATOR: Ise PERIMETER TREATMENT GALLONS 30 8. STATE ROAD 7 PLANTATION, FLORIDA 33317 954- 58441588 1- 800 - 749 -8588 FAX: 954384 -6117 ilomkittithiothilaNs ■ RECEIPT DATE g No .0299 RECEIVED FROM (We iLd Af ADDRESS .4-1-1- A - A 61 41 kx3 1-; los * %la A ".NH 62.15H gizibH DOLLARS $ Piq5: FOR e201 5 11 14 10 OH 34-210k 3405 A op • t4tzetole.- ACCOUNT AANitifiT AMT. PAID BALANCE DUE HOW PAID CASH CHECK MONEY ORDER BY July 19, 1999 7050NW42S Miami, FL 33166 Dear Contractor , re: Your check number #5526 Enclosed is a copy of your uncollected check for $1,420.80 returned to us by your bank due to non- sufficient funds. Please make payment no later than July 26, 1999 in the amount of $1,445.80 to cover the check including the return check fee charged by the bank. Payment must be be in the form of certified funds only. This includes cash, money order, cashier's check, etc.... There is currently a hold on all permits already issued to your company. No further work is to be done on any property until the permit fee is paid. There will be no permits issued until the amount due is paid in full. If payment is not received by the due date, the information will be forwarded to the Village Attorney for legal action. Sincerely, d Lisa Keeley Accountant Receivables enclosure 09)ravinu C�io4 ea 0)-taz 10050 .2nd Cryenue oAreemu (9'194 L E 33138 Wfinaince ..geiia/i irne/ist (305) Z95 -2208 VIA CERTIFIED MAIL # Z 419579 906 - 131 , 27-20:03 12:35 FROM: TO: �5443J344 &I& 1/003 COMMENTS: COMMENTS: • w,•= ;;i: • COMMENTS: PPROVED BY PE OF INSPEC ON: COMMENTS: APPROVED BY APPROVED BY APPROVED 8Y COMMENTS: TYPE OF INSPECTION: 1 c4. , t tit7c7 11111111. : APPROVED BY DATE I/ TYPE OF INSPECT! • " COMMENTS: PPROVED BY DATE: DATE: PPROVED BY DATE: /2 LOG OF APPROV: TYPE OF INSPECTION: „oft Js COMMENTS: toommxwmgAmomwompowisnmo 307.2 EXHIBIT 2 LOG OF APPROVED INSPECTIONS TO COMPLY WITH SFBC 307.2 PERMIT* ADDRESS: A!E CONTRACTOR COMMENTS: TYPE OF INSPECTI N: COMMENTS: r t ' /ie,r)r. PROVED SY TYPE OF INSPECTI +N: PPROVED BY DATE: - PE OF INSPECT* PPROVED BY DATE: / COMMENTS: PPROVED BY COMMENTS: TYPE OF INSPECTI'a N: PPROVED BY DATE: APPROVED BY DATE: COMMENTS: DATE: DATE: u EXHIBIT 2 LOG OF APPROVED INSPECTIONS TO COMPLY WITH SPBC 307.2 TYPE OF INSPECTION: COMMENTS: APPROVED BY COMMENTS: APPROVED BY APPROVED BY PE OF INSPECTION: PE OF INSPECTION: COMMENTS: PPROVED BY PE OF INSPECTION: COMMENTS: APPROVED BY 4 TYPE OF INSPECTION: A/'Z - "2 fill • DATE: / off' TYPE OF INSPECTION: 12/ ► /0. ;430,0.4. q COMMENTS: x: f DATE: m il PPROVED By,/ DATE i DATE: PPRO '_D BY_ TYPE OF INSPEC I +N:M 1e Agrft Ai`/. vgeigo eole_ 07 /. DATE: . 1..f 2 Y LATE: .0? ve4 DATE: / - 5( -45 PERMIT # ADDRESS: A/E CONTRACTOR TYPE OF INSPEC1I COMMENTS: • PPROVED BY N: giumecttifmsuseahmiuMSPOVONAIYEA307 SAM DATE: T Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Contractor's Name: Job Address: I l3oo AJE a Prue ROOF CATEGORY ❑ (Low Slope Application) ❑ (Nail -On Tile) ,'(MortaAdhesive Set Tile ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) ROOF TYPE ❑ New Roof Re- roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft Sloped Roof Area (ft 0 V O 1 1 Total (ft a ' 0 ? Master Permit No. /// – Exposure category (per ASCE 7 -88): C— Building Classification category (per ASCE 7-88 table 1): Ft. v Ft. n A C( Deck type: ATTACHMENT Fastener Type: SPACING Field: Perimeter. Corner: DETAIL 1 & 2 ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) Page -1 leg Description MI Tile Hoof Ridge Material Hip Material — Ualleg Material — Gable Material -- Eaves Material — L- Flasbing/S.Stop SF -LE 28889. 1458.88 688.92 476.89 586.95 124.26 1258.95 198.86 ■ EA/SI. UNIFORM ROOFING PERMIT APPLICATION PROCESS No. SLOPED SYSTEM DESCRIPTION MEANDEIGHT 20 DETAIL 3 Fastener type & spacing: II 73- Azar /lo ci_ ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance-Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals vntaxpq "x X (Aerodynamic Multiplier): I ) - (Pmax2:1 I 73 x x (Aerod multiplier): ) - (Pmax3: 10( .2-x X (Aerodynamic Mukiplier): 2 - ) - TILE CALCULATIONS M 5 ; 2 ° = 1 PCA: i g 9 0 M = zz-5 M ° = M 1 To C t I PCA: \./ u - OQVA I),? C) Page-2 uoicuiars 08:47 FAX 1 561 338 5391 man APPROVED: 01/08/98 RODUCT ONTROL N i TICE OF A Monier Roof Tile 135 N.W. 20 St. Boca Raton, FL 33431 Your application for Product Approval of Bermuda Flat Tile 1 Internet mall address: postmaster @buildingcodeonline.com MONIER LI1 -EIILE ACCEPTANCE NO.: 96-0528.06 Renews No. :941221.08 EX Ol/ 8/01 CEPTAN E METROPOLITAN DADE COUNTY. FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 MIAMI, FLORIDA 33130.1583 (305) 375 -2901 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6339 under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Redland Technologies, The Center for Applied Engineering, Inc. and Professional Service Industries, Inc.. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -12 and the standard conditions on page 13. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, immediately. The Building Code Compliance Office reserves then t to revoke this approval, if it determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Raul Rodrl Product Control Supervisor S IS THE COVERSAEET SEE ADDITIONAL » A ES FOR SPECIE COnffism UIL CODE OC MMITT>i;E This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in�a1le County, Florida under the conditions set forth above. Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County Homepage: bttp :/ /www.buifdtngcodeonline.com gl002 06/26/98 08:48 FAX 1 561 338 5391 MONIER LINg1 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Product Control No.: 9 6 - 0528.06 &g am Monier Roof Tile 135 NW 20 St. Product Control No.: 2 6 -15281 Boca Raton, FL 33431 Ca e r : Prepared Roofing Sub Cateaory Tile Mortar Set/Adhesive Set SS ub e: Concrete System escr iption Monier Roof Tile is a member of the Redland Group, a world wide producer of primary building products and roof tile. Monier manufacturers concrete roof tile for nail -on, mortar set or adhesive set applications in plants throughout the United States ranging from Washington State to Florida. All tile is manufactured from extruded concrete consisting of Portland Cement, plasticizer, iron and metallic oxides, and blended aggregates. This Product Control Approval relates to M i ier's "Bermuda Flat" tile profile. Re er to a r ri to Product Control A royals f r other the r Iles. Monier sells tile systems through local distribution and directly to consumers. All profiles have matching trim pieces used for rake hip, ridge hip, and valley terminations. Tile system accessories such as underlayment, ventilation systems and flashing systems are also available. These accessories are manufactured for all profiles and form a part of this Product Control Approval. Monier's "Bermuda Flat" roof tile has been tested in compliance with the South Florida Building Code requirements for concrete, mortar or adhesive set tile applications. The minimum roof slope for Monier's "Bermuda Flat" mortar or adhesive set tiles shall be 2 " :12 ". See the "Profile Drawing" section in this approval for the "Bermuda Flat" profile drawing. The Monier "Bermuda Flat" tile profile has been tested for both wind characteristics and static uplift performance, therefore, any consideration for installation shall be done as a 'Moment Based System'. Data for attachment calculations is noted in Tables 1 through 3 of this approval. Contact: Reese H. Moody Technical Service Accessories Manager 135 N.W. 20 St. Boca Raton, FL 33431 (407)338 -8200 Page 2 of 13 Approval Date: January 8, 1998 Expiration Date: January 8, 2001 Frank Zuloaga Roofing Product Control Examiner fj003 06/26/98 08:53 FAX 1 561 338 5391 Comments: SYSTEMS Deck Type: Wood, Non - insulated Deck Description: New construction 19 /32" or greater plywood or wood plank. SYSTEM D: Mortar or Adhesive Set Application Slope Range: 2 " :12" to 7 " :12" Note: System D is only acceptable in this slope range. Underlayment: Install choice of approved underlayment County Protocol PA 120, in compliance with Section of PA 1I20. Dade System Limitation #6. Roofing Tile: Install tile in compliance with PA 120 using one of the approved mortars or .adhesives noted in this approval. Mortar or adhesive shall be applied in compliance with the mortar manufacturer's Roofing Component Product Control Approval. The mortar or adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with PA 115 or PA 127. The mortar and adhesive attachment data is noted in Table 3, attached. 1. For re -roof applications, 15 /32" plywood is an acceptable substrate. 2. For mortar set applications, the first three courses of tile shall be nailed with not less than one nail per tile. As an alternate, the first three courses of tile shall be applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than 3 /8" which is mechanically attached to the deck with not less than one roofing nail every 1 ft For roof pitches from 6 ":12" to 7 " :12 ", every third tile of every fifth course, beginning at the eighth course, shall be nailed with not Tess than one nail per tile. Page 8 of 13. • - MONIER LIFETILE Product Control No.: 96-0528.06 Frank Zuloaga Roofing Product Control Examiner li11 009 06/26/98 08:54 FAX 1 581 338 5391 BONIER LIFETILE .Product Control No.: 96- 0528.06 SYSTEM LIMITATIONS 1 . The standard minimum roof pitch for Monier "Bermuda Flat" mortar set or adhesive set tile applications is 2" rise in 12" run (2":12"). The maximum roof pitch for mortar set or adhesive set tile applications is 7" rise in 12" run (7 ":12 "). 2. Monier's "Bermuda Flat" tile profile has not been tested for nail -on applications, therefore, System A, (Counter - Batten Nail -On Application), System B (Direct Deck Nail -On Application) and System C (Horizontal Batten Nail -On Application) do not form part of this approval. 3. System installation shall be in compliance with the system sControl Approval. Mortar set or adhesive set tile shall bea ttached using an approved mortar or tile adhesive noted in this approval, the data of which is noted in Table 3 of this Approval. The method of attachment utilized shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Dade County Protocol PA 115 or PA 127. 4. For mortar set applications, the first three courses of tile shall be nailed with not less than one nail per tile. As an alternate, the first three courses of the shall be applied in mortar or adhesive over a single layer of minimum 12 ga. wire mesh with square openings of not less than 3/g" w mechanically attached to the deck with not less than one roofing nail eve 1 ft2. F hi roof is or from 6 " :12" to 7":12", every third tile of every fifth course, beginning at beginning eighth course shall to nailed with not less than one nail per tile. 5. For mortar set or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be required not less than 30 days after application to confirm tile adhesion. The results of this testing shall be reported to the Building Official and the installer stating that the application has passed or failed PA 106 testing. If the application fails PA 106 testing, the report shall state which portion of the test was failed; Category I (examination for loose tile) or Category 2 (uplift testing of tile). Subsequent to testing, the installer may repair not more than 5% of field area tiles and 10% of perimeter area (i.e. ridge/rake) tile with approved tile adhesive. The installer shall place an identifiable marking on each repaired tile for future reference. Any PA 106 re -test shall not include any marked tile. 6. For mortar or adhesive det tile applications, 30/90 hot mopped underlayment applications may be installed perpendicular to the roof pitch prior to June 1, 1995 unless stated otherwise by the material manufacturer. Thereafter, 30/90 underlayment systems shall be installed parallel to the roof pitch in compliance with Appendix 'A' of Dade County Protocol PA 120. 7. All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 8. The Monier "Bermuda Flat" tile profile has been tested for both wind characteristics and static uplift performance, therefore, attachment calculations for installation in compliance with Dade County Protocol PA 115 or PA 127 shall be done as a 'Moment Based System' Page 9 of 13 uloaga Roofing Product Control Examiner IIolo 08/28/98 08:55 FAX 1 581 338 5391 Page 10 of 13 MONIER LIFETILE Product Control No.: 96-0528.06 SYSTEM LIIVIITATIONS (CONTINUED) 9. Applications for roofing permits shall include a completed Section II of the Uniform Building Permit, a copy of Monier Roof Tile's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Rooting Component used in the proposed tile application. Reference shall be made to appropriate data for the required fire rating. 10. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Code and related protocols. Samples taken shall be in compliance with Dade County Protocol PA 112, Appendix 'A'. 11. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida Building Code. Frank Zuloaga Roofing Product Control Examiner 06/26/98 08:56 FAX 1 561 338 5391 DATA FOR ATTACXiMENT CALCULATIONS Page 11 of 13 MONIER LIFia'ILE Product Control No.: 96- 0528.06 Table 1: Aerodynamic Multipliers - ? (ft from PA 108 Testing X ( Batten A . ' lication Tile Profile Bermuda Flat Flat Tile ). (ft') Direct Deck A • plication 0.24 Tile Profile Monier Bermuda Flat Tile 3' :12" or 5.20 5.01 7":12" or greater Table 2: Restoring Moments due to Gravity - Mg (ft -lbf) from PA 101 Testing ' less 11111 1111161111 6 ":12" 4.89 N/A Table 4: Attachment Resistance Expressed as a Moment - M, (1t -lbf) from PA 101 Testing The Profile Monier Bermuda Flat Flat Tile Tile A . • lication Mortar Set Adhesive Set Attachment Resistance 39.00 118.90 ran Zuloaga Roofing Product Control Examiner gj 012 08/26/98 08:57 FAX 1 581 338 5391 MONIER LI1+k1'ILE • 1" PROFILE DRAWING BERMUDA FLAT FLAT TILE Page 12 of 13 Product Control No.: .96- 0528.06 Frank Zuloaga Roofing Product Control Examiner 1J013 06/26/98 08:58 FAX 1 338 5391 1VIonier Roof Tile 135 N.W, 20th St. Boca Raton, FL. 33431 MONIER LIFETILE Product Control No.: 96 -0528 06 ACCEPTANCE NO.: 96- 0528.06 APPROVED : Janu 81993 EXPIRES : Januu 3 2001 O I E FA CEPTANCE STA C ND IO I Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Metro -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the is not in compliance with the code changes; b) The product is no Longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Metro -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer: 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through 13. END OF THIS ACCEPTANCE Page 13 of 13 uloaga Roofing Product Control Examiner WIJ014 LG ENGINEERING SERVICES, INC. Consulting Engineers North Office: 7370 N.W. 36th Street Suite 374 Miami, Florida 33166 Tel: (305) 994 -8128 Fax: (305) 994 -8135 Allied Roofing Industries 7050 Northwest 42 Street Miami, Florida 33166 RE: Limited Askesios Surrey(Rod) Barry University Thompson Hall Building 2 11300 Northeast 2 Avenue Miami Shores, Florida Dear Sirs: South Office: 13380 5.W 131 Street Suite 120 Miami, Florida 33186 Project Number: LG98- 1286.ASB EN•G- I- N-EE•R December 15, 1998 On December 14, 1998, a representative of LG Engineering Services, Inc. performed a limited asbestos survey on the roof at the above referenced location. The survey entailed sampling the roof materials which will be disturbed at the time of the re- roofing activity. A total of eleven (11) samples were collected from the above referenced structure; three (3) from the roof field membrane, two (2) from the roof perimeter flashing, two (2) from the roof opening flashing, two (2) from the roof cement used for patching, and two (2) from the roof pitch pans. Based on the laboratory analysis, the roofing materials listed below which were obtained from the roof at 11300 Northeast 2 Avenue (Barry University - Thompson Hall), Miami, Florida on December 14, 1998 we r efo:0d to be asbestos- containing: b mate r 4al < It i ........................ ............................... ....................... ............................... ........................ ............................... ....................... ............................... e roxt at : g ttanti ................. ............................... ... ............... ...... ............................... ....................... ............................... ......................... ..... +} ......................... . is is p� s un ate an Attached is our full report for your review. LG Engineering Services, Inc. appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; LG Engineering Services, Inc. / 9t$2 Leo Garcia, P.E. Asbestos Consultant License Number EA 0000077 Asbestos Business Organization License Number ZA 0000091 RE: Limited Asbestos Roof inspe t1un Barry University Thompson Hall Building 2 11300 Northeast 2 Avenue Miami Shores, Florida. Project Number: LG98- 1286.ASB LG Engineering Services, Inc.-- Limited Asbestos Survey (Roof) — Project Number: LG98 -1286 -- Page 1 INTRODUCTION AUTHORIZATION SCQPE OF SERVICES Report of Limited Asbestos Roof Inspection for Barry University Thompson Hall Building 2 11300 Northeast 2 Avenue Miami Shores, Florida Project Number: LG98 -1286 This report presents the result of a limited asbestos roof survey performed for the proposed re- roofing project located at 11300 Northeast 2 Avenue, Miami Shsores, Florida. This inspection was performed on December 14, 1998. This inspection was authorized verbally on December 14, 1998 by a representative of Allied Roofing Industries. The scope of services for this project were the following: 1. Sampling of Roofmg Materials 2. Laboratory Analysis 3. Report Preparation En Inc.-- Survey - Project Number: LG98 -1286 -- Pa e 2 LG Engineering Services, Inc Limited Asbestos Survey (Rood Project g The bulk sampling procedures used for the collection of suspect materials first required the establishment of homogeneous sampling areas, which are defined as areas of materials of the same type and applied during the same general time period. The homogeneous sampling areas were then examined and representative samples of materials were obtained. The U.S. Environmental Protection Agency (EPA) has published guidelines and recommendations for obtaining samples of asbestos - containing materials. These guidelines were followed during our survey, where appropriate. Additionally, samples of these materials are obtained at our discretion based on past experience. All of the roofmg materials sampled at the time of our inspection were placed in individual plastic container prior to transporting them to the laboratory. These samples were clearly identified, both on the container and the field data sheet for future reference. The client is made aware that although the areas from which the samples were obtained were patched with a temporary patch only, there is always a chance that the roof may leak. LG Engineering Services, Inc. assumes no responsibility for any leaks as a result of this survey. LIMITATIONS The analysis of bituminous roofmg material by Polarized Light Microscopy (PLM) in conjunction with Dispersion Staining is accurate only on a qualitative basis and only when the laboratory reports that asbestos was detected in the samples analyzed. A laboratory analysis report which states that no asbestos was detected in the sample does not necessarily exclude the possibility that asbestos may be present in the homogeneous area represented by the sample analyzed. Furthermore, a quantitative appraisal of asbestos content in a bituminous roofmg sample is extremely subjective and a high interlaboratory standard deviation of analysis results on side -by -side samples is common. It is the material composition and production processes used in the manufacture of some bituminous roofmg material which create problems for analysis using Polarized Light Microscopy for asbestos identification and quantification. We have endeavored to observe the existing conditions within the area surveyed using generally accepted procedures. Regardless of the thoroughness of a survey, there is LG Engineering Services, Inc. -- Limited Asbestos Survey (Roo) — Project Number: LG98 -1286 -- Page 3 always the possibility that some areas containing asbestos were overlooked, inaccessible, or different from those at specific sample locations. Therefore, conditions at every location may not be as anticipated and as summarized in the report. In addition, renovation or demolition may uncover altered or differing conditions. We recommend that you notify us if any changed conditions are encountered so that we can assess the situation and its impact on the original recommendations. The results and conclusions contained in this report pertain to conditions which were observed at the time of the survey. No representations or assumptions are made as to the nature of past conditions or future occurrences from this report. The survey was designed to assist the roofmg contractor and his representatives in locating asbestos- containing materials (ACM). Under no circumstances is this survey and the quantities found in the survey to be used for bid purposes. This report is intended for the exclusive use of Allied Roofing Industries Use of this report or reliance upon information contained in this report by any other party acts as an agreement by that party to the same terms and conditions under which our services were provided. Furthermore, any use of this report by a party for purposes beyond those intended by ourselves and Allied Roofing Industries will be at the risk of that party. LG Engineering Services, Inc.-- Limited Asbestos Survey (Roof) — Project Number: LG98 -1286 -- Page 4 Based on the laboratory analysis, the roofing materials listed below which were obtained from the roof at 11300 Northeast 2 Avenue (Barry University - Thompson Hall), Miami, Florida on December 14, 1998 itere found to be asbestos - containing: and a category I non-friable material < bituminous. The approkimate approximate uare feet and it is in fair condition.. c Laboratory Results Section, . p o and' the drawing contau e otogra f cation. ver tl0 LG Engineering Services, Inc. -- Limited Asbestos Survey (Roof) — Project Number: LG98 -1286 -- Page 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 • Field Data Sheet Thompson Hall Building 2 11300 Northeast 2 Avenue Miami Shores, Florida North Sample Location i t< /d; o. i l / / (( ( <1 Z Asbestos - Containing Roofing Material , /7 / /(lf(/ ,! 1 f( l ! l (1 (1 / / r., ll ( ( �l i ,e; r t h Approximate Sample Location LG Engineering Services, Inc. Photographic Documentation -- Barg University, Miami, Florida • Photographic Documentation Thompson Hall Building 2 11300 Northeast 2 Avenue Miami Shores, Florida Roof Field Membrane LG Engineering Services, Inc. — Photographic Documentation -- Barry University, Miami, Florida Roof Field Membrane Roof Field Membrane LG Engineering Services, Inc. — Photographic Documentation -- Barry University, Miami, Florida Roof Perimeter Flashing Roof Perimeter Flashing LG Engineering Services, Inc. — Photographic Documentation -- Barry University, Miami, Florida 1 Roof Opening Flashing Roof Opening Flashing LG Engineering Services, Inc. — Photographic Documentation — Barry University, Miami, Florida Roof Cement Roof Cement LG Engineering Services, Inc. — Photographic Documentation -- Barry University, Miami, Florida Roof Pitch Pans Roof Pitch Pans LG Engineering Services, Inc. — Photographic Documentation -- Barry University, Miami, Florida Qualifications Thompson Hall Building 2 11300 Northeast 2 Avenue Miami Shores, Florida IN L DATE' . . I BATCH NUMBER . MN M EN 111111 N M SU UM MN E MI NM OM MI The Nam edhelow Under the provisions of t hapterF Expiration date: !".?r; V GARC 1353' €Iw tt' CLI StLi amen below s .. � ' Er45E Under the provisions of Chapter 469 Expiration ", date: ; NOV ` 3 ' 3 li E DATE I BATCH NUMBER 2 " DISPLAY AS REQUIRED BY LAW I L; REGU ATI AC# AIT QO ' STATE OF FLORIDA: E5 AND PROFS A B STO ARD T_ FARRE SECRETARY OM MI UM Ma U NM s••• OM NM I E MR MI RN • rassrb Exam:: February 15, 1998 Arcrrbaatiun''Eipirr February 14, 1999 5111 -b . igaguicawuras ; Rua?) ` Burk 167 Jackannutllc lnriaa 32217 uurtitito � # LEO GARCIA HS Bui tSSf tttLtj nut .ttrtt[itatt rrqut -rtmtnto far REFRESHER_ FACILITY SURVEY AND BUILDING SYSTEMS (Reaccreditation for Inspector under TSCA Title II/AIJERA) IIIIIII I= s — = I O I MN M M I I— = M=— s , tassrd futon: February 15, 1998 Acerrlitatinn .xturts:" February 14, 5111 -1 ilafiwrabnms Iao Duct afultll mrt ctrl ttratie rtquirtmeuto for REFRESHER: FACILITY SURVEY AND BUILDING SYSTEMS (Rcaccreditation for Inspector under TSCA TitleIUAHERA) Y�ultr 167 incksuttutUtr. Martha 32217 (9II4) 35a- 71189 ttrttf tto Oat MOHAMAI) SONNY SALLEI-I Miami, FL f;8rrtiftratr Numbrr 3374 ilariign 1f_ iiscnflaur Laboratory Analysis Thompson Hall Building 2 11300 Northeast 2 Avenue Miami Shores, Florida 1' L 'AR 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DATE: CLIENT NAME: PROJECT NAME: ENV!RONMENT,4 L INC. Asbestos Consulting • Radon Measurements • Lead Assessments • Indoor Air Quality • Laboratory Services • Air Monitoring & Analysis REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS December 15, 1998 LG ENGINEERING LGBB -1286 IS ASBESTOS PRESENT CHRYSOTILE % AMOSITE % CHROCIDOLITE % OTHER - SPECIFY % OTHER FIBROUS GLASS % CELLULOSE % SYNTHETICS % OTHER - SPECIFY tY 10 - 15 35 -45 10-15 35 -45 1 0-1 5 35 -45 OTHER NON - FIBROUS MATERIALS PRESENT MAJOR COMPONENT % OF TOTAL SAMPLE RFMARKS: ASBESTOS CONTENT None Detected FIBROUS MATERIAL PRESENT t ilinders Not Analyzed The sample components are identified by polarized Tight microscopy methods. Percentages are estimated by visual means. Analyzed by: Alexander Front, I.H. Page 1 of 4 None Detected 3inders Not Analyzed coupled Environmental Consulting Services Asbestos Business license # ZA- 0000164 CLIENT SUBMITTED SAMPLE PROJECT*: 981359 None Detected = inders Not Analyze with dispersion staining SAMPLE 1.13. # 981359 -1 981359 -2 981359-3 ADDITIONAL LD. DATA Roof Material Roof Material Roof Material BULK SAMPLE Field Membrane Field Membrane Feld Membrane SAMPLE COLOR Tan /Black Tan /Black Tan/Black IS MAT'L HOMOGENEOUS No No No IS SAMPLE LAYERED Yes Yes Yes — IS SAMPLE FRIABLE No No No IS SAMPJ, E FIBROUS Yac ., YPS Ypc 'AR 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DATE: CLIENT NAME: PROJECT NAME: ENV!RONMENT,4 L INC. Asbestos Consulting • Radon Measurements • Lead Assessments • Indoor Air Quality • Laboratory Services • Air Monitoring & Analysis REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS December 15, 1998 LG ENGINEERING LGBB -1286 IS ASBESTOS PRESENT CHRYSOTILE % AMOSITE % CHROCIDOLITE % OTHER - SPECIFY % OTHER FIBROUS GLASS % CELLULOSE % SYNTHETICS % OTHER - SPECIFY tY 10 - 15 35 -45 10-15 35 -45 1 0-1 5 35 -45 OTHER NON - FIBROUS MATERIALS PRESENT MAJOR COMPONENT % OF TOTAL SAMPLE RFMARKS: ASBESTOS CONTENT None Detected FIBROUS MATERIAL PRESENT t ilinders Not Analyzed The sample components are identified by polarized Tight microscopy methods. Percentages are estimated by visual means. Analyzed by: Alexander Front, I.H. Page 1 of 4 None Detected 3inders Not Analyzed coupled Environmental Consulting Services Asbestos Business license # ZA- 0000164 CLIENT SUBMITTED SAMPLE PROJECT*: 981359 None Detected = inders Not Analyze with dispersion staining -- •. wry •- .... -.- r frvr•�• FIBROUS GLASS % 10-15 10-15 10 CELLULOSE % 25 -35 25 -35 25 -35 SYNTHETICS % Flashing Silver /Black SAMPLE COLOR 1S MAT'L HOMOGENEOUS nTHFR - 5PFCIFY % . No IS SAMPLE LAYERED Yes Yes — - - -- ..._..- --. --' -.. r•.�...••.• MAJOR COMPONENT Binders Not Analyzed Binders Not Analyzed Binders Not Anal s4 % OF TOTAL SAMPLE REMARKS: Roof Material BULK SAMPLE Flashing Black Flashing Black Flashing Silver /Black SAMPLE I.D. # 981359 -4 981359 -5 981359 -6 ADDITIONAL I.D. DATA Roof Material Roof Material Roof Material BULK SAMPLE Flashing Black Flashing Black Flashing Silver /Black SAMPLE COLOR 1S MAT'L HOMOGENEOUS No No No IS SAMPLE LAYERED Yes Yes Yes IS SAMPLE FRIABLE No No No IS SAMPLE FIBROUS YPC YPC Yes _ ! ARS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ENC/IIWNMENTAL ! iVC. Environmental Consulting Services Asbestos Business License #ZA- 0000164 Asbestos Consulting • Radon Measurements • Lead Assessments • Indoor Air Qualitg • Laboratory Services • Air Monitoring & Analysis REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS DATE: December 15, 1998 CLIENT NAME: LG ENGINEERING PROJECT NAME: LG98 -1286 OTHER NON- Paae 2 of 4 CLIENT SUBMITTED SAMPLE PROJECT #: 981358 The sample components are identified by polarized light microscopy coupled with dispersion staining methods. Percentages are estimated by visual means. Analyzed by: Alexander Front, I.H. IS ASBESTOS PRESENT Yes Yes Yes CHRYSOTILE % 7 - 9 7 - 9 7 - 9 AMOSITE % CHROCIDOLITE % OTHEJI - SPPCIFY % ! ARS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ENC/IIWNMENTAL ! iVC. Environmental Consulting Services Asbestos Business License #ZA- 0000164 Asbestos Consulting • Radon Measurements • Lead Assessments • Indoor Air Qualitg • Laboratory Services • Air Monitoring & Analysis REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS DATE: December 15, 1998 CLIENT NAME: LG ENGINEERING PROJECT NAME: LG98 -1286 OTHER NON- Paae 2 of 4 CLIENT SUBMITTED SAMPLE PROJECT #: 981358 The sample components are identified by polarized light microscopy coupled with dispersion staining methods. Percentages are estimated by visual means. Analyzed by: Alexander Front, I.H. - - - - -- - - - -- - - -- ••■•-• ■ rr..r.r SAMPLE I.D. # 981359-7 981359 -8 981359 -9 ADDITIONAL I.D. DATA Roof Material Roof Materiel Roof Material BULK SAMPLE Flashing Silver /Bleck Cement Silver /Black Cement Silver /Black SAMPLE COLOR IS MAT'L HOMOGENEOUS No No No IS SAMPLE LAYERED Yes Yes Yes 1S SAMPLE FRIABLE No No No IS SAMPLF FIBR[1LIS YRC YaC V - - - - -- - - - -- - - -- ••■•-• ■ rr..r.r 1S ASBESTOS PRESENT Yes None Detected None Detected CHRYSOTILE % _ 7 - 25 -35 25-35 AMOSITE % SYNTHETICS % CHROCIDOLITE % OTHER - SPECIFY ah OTHER - SPECIFY �„ - - - - -- - - - -- - - -- ••■•-• ■ rr..r.r I.. FIBROUS GLASS % 10 -15 10 10 CELLULOSE % 25 -35 25-35 25 -35 SYNTHETICS % OTHER - SPECIFY ah ARSFNUIaONMENTAL, INC. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Environmental Consulting Services Asbestos Business License # ZA- 0000164 Asbestos Consulting • Radon Measurements• Lead Assessments • Indoor Air Quality• Laboratory San/ices • Air Monitoring & Analysis REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS DATE: December 15, 1998 CLIENT NAME: LG ENGINEERING PROJECT NAME: LG88 -1286 CLIENT SUBMITTED SAMPLE PROJECT t!: 981358 The sample components are identified by polarized light microscopy coupled with dispersion staining methods, Percentages are estimated by visual means. Analyzed by: Alexander Front, I.M. Paaa ;R of d MAJOR COMPONENT Binders Not Analyzed 3inders Not Analyzed Binders Not Analyzed % OF TOTAL SAMPLE _REIVIAR S, ARSFNUIaONMENTAL, INC. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Environmental Consulting Services Asbestos Business License # ZA- 0000164 Asbestos Consulting • Radon Measurements• Lead Assessments • Indoor Air Quality• Laboratory San/ices • Air Monitoring & Analysis REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS DATE: December 15, 1998 CLIENT NAME: LG ENGINEERING PROJECT NAME: LG88 -1286 CLIENT SUBMITTED SAMPLE PROJECT t!: 981358 The sample components are identified by polarized light microscopy coupled with dispersion staining methods, Percentages are estimated by visual means. Analyzed by: Alexander Front, I.M. Paaa ;R of d WINCH FIBROUS MATERIAL PRESENT SAMPLE I.D. # 981359 -10 981359 -11 ADDITIONAL I.D. DATA Roof Material Roof Material BULK SAMPLE Pitch Pans Pitch Pans SAMPLE COLOR Silver/Black Silver/Black IS MAT'L HOMOGENEOUS No No IS SAMPLE LAYERED Yes Yes IS SAMPLE FRIABLE N No 1 1$ SAMPI F FIBROUS Vac YPR WINCH FIBROUS MATERIAL PRESENT FIBROUS GLASS % 10 -15 10 -15 CELLULOSE % 25 -35 25 -35 SYNTHETICS % OTHEO - SPECIFY 1 A RSENWOIVMEIVTAL iNC. Environmental Consulting Services Asbestos Business License # ZA- 0000164 Asbestos Consulting • Radon Measurements • Lead Assessments • Indoor Air Quality • Laboratory Services • Air Monitoring & Analysis 1 1 1 1 1 1 1 1 1 1 f 1 1 1 REPORT OF BULK SAMPLE ANALYSIS FOR ASBESTOS DATE: December 15, 1998 CLIENT NAME: 1.6 ENGINEERING PROJECT NAME: LG98 -1288 IS ASBESTOS PRESENT CHRYSOTILE % AMOSITE % CHROCIDOLITE % OTHER - SPECIFY % Yes 5 -7 Yes 5 -7 MAJOR COMPONENT % OF TOTAL SAMPLE REMARKS= ASBESTOS CONTENT OTHER NON - FIBROUS MATERIALS PRESENT 3inders Not Analyzed The sample components are identified by polarized light microscopy coupled with dispersion staining methods. Percentages are estimated by visual means. Analyzed by: Alexander Front, I.H. 1 1 Page 4 of 4 CLIENT SUBMITTED SAMPLE PROJECT #: 981358 3inders Not Ana ed