RF-10-1619RE -ROOF TILE Passed Inspector Comments Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until 'Inspection Number: INSP - 151096 Permit Number: RFC -9 -10 -1619 I Inspection Date: October 27, 2010 Inspector: Bruhn, Norman Owner. , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue LaVoie Hall Miami Shores, FL 33138 -0000 Project: <NONE> Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Contractor: INFINITY ROOFING AND SHEET METAL INC Building Department Comments October 27, 2010 For Inspections please call: (305)762 -4949 Permit Type: Roof Inspection Type: Final Roof Work Claslsification: Tile Phone Number Parcel Number 1121360010160 -12 Phone: (954)917 -7107 Page 1 of 1 i (: I i v °TInA Miami Shores Village Building Department BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building riloo fing Owner's Name (Fee Simple Titleholder) BARRY UNIVERSITY Phone # q S f -917 - 71 0 T Owner's Address 11300 NE 2 AVE City MIAMI SHORES S tate FL Tenant/Lessee Name Job Address (where the work is being done) 11300 NE 2 AVE - Lavoie City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # 11 - 2136 - 000 - 0050 Is Building Historically Designated YES NO Contractor's Company Name INFINITY ROOFING AND SHEET METAL, INC. Phone # 954 - 7107 Contractor's Address 1150 SW 10TH AVE STE 201W City POMPANO BEACH State FL Qualifier Name JOHN B MITALA Value of Work For this Permit $ Type of Work: Describe Work: Structural Review. $ /0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Colt r- (■ IQ Permit No. octo- \w C Master Permit No. zi 33161 Phone # zi 33069 ph # 954 -849 -4778 Square / Linear Footage Of Work: State Certificate or Registration No. CCCO57467 Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Qc S a J= ['Addition ['Alteration ❑New El Repair/Replace ❑ Demolition Fees Submittal Fee $ Permit Fee $ \ 3A.) CCF $ CO /CC Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Total Fee Now Due S 13 See Reverse side -4 Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) NIA Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be app 1"', r <, a reinspection fee will be charged Signature who is personally known to me or who has produced NOTARY PUBLIC: Sign: Print: My Commission Expires: * * * * * * * *MM * *t *tt* * *t * * ** **a APPLICATION APPROVED BY: (Revised 07/10/07) As identification and who did take an oath. ' . ila . P(4 Notary Public State of Florida My Commission DD613542 LI Signature Owner or Agent The foregoing instrument was acknowledged before me this 31 sr The foregoing day of4 , 20 fl by C, oiriar frder 9 Contractor ent was acknowledged before me this 6 day of ,CS , 20 /0 by JOHN B MITALA who is personally known to me or who has produced as iden NOTARY PUBLIC Sign: Ark Print: . �T L 1 ,, ,� t MARTIN* ADAMS Commission # DD 898064 My Commission Expires 10 - 07 - 2013 , Bonded Through Notional Notary Assoc. , ® - -- My Commission Bop 19 /;//5 ** * *M* * * * * *tttttttt *Malt t * *** * *M ** *******210101%**11 lilt * ** ***** * * *** *** Rf9 WR1an& Vs *Fs Plans Examiner Engineer Zoning A SECTION 1524 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section.. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. Aesthetics - Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 9GRi 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). ►�� 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code provides the option of maintaining this appearance. 5. Ponding Water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. ` 1. pp ee 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the Florida Building Code, Plumbing. bfW 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to co• er additional venting which can result in extending the service life of the roof. zigie ) i f / / I% k, eft/Agent's Signature Date (^ • 1. or's Signature 11300 NW 2ND AVE MIAMI SHORES Property Address Permit Number Rev:1/20/2005,Computer Services, Budding Department HIGH- VELOCITY HURRICANE ZONES 44,208 SECTION R4402.14 HIGH-VELOCITY HURRICANE ZONES }-- UNIFORM PERMIT APPLICATION l Bddding Code Edt • • .••• ••• : •• • • • • • INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS S :QF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND 'ATTACH THE REQUIRED DOCUMENTS AS NOTED SOW: • ATTACHMENTS:-REQUIRED: ? . Fire Dir dory Lbiting page n't Product ;= FBA R don Roof Testi .: Colas • ` 1 From Produdt•Approvat: Page Specific-Sy OSSIFTP Specific System L //*one .I C Limitations Design Calculations per Section R4403, or Applicable, RAS 127 or RAS 128 . • • • • • • •• • • •. 1 .. • • :. • • • '••• • • •• •• • • • • • • ••• • . • • •••• • • • •' i•• ••• ••- ' • • • • • •.. • . • • • . • • • • ••■•• •• ••• • •• • • • • •' •• •• •' •••• , • • • Co • •• • • • • • , i • • • : ••• • • • ••• ■ • • FLORIDA BUILDING CODE - RESIDENTIAL r o f a • a i s. it :iws • I nlrlk• ' ,Po rt ,._ _. ...._. Pr rikr • Cot s ,., Oti Adctresti y a O�e' ;r,3,41 J/300 ;.. " %ove. / �4 � � 6/ 3 MeclordostiAistioneitti. :l { 1 rrd Sit The C7_ MOW ,P i i si- :.- El :. 4.... :. I New awe . .L1 R, D : ng r filikatisti . • Ro SEP .1 21i1t} • • Coilinifttii 2004. 9411084111301 h ROOfFisint IIIusbset ieve's and **o 4 r Ine r .o. . PPIF$ o w 010 Induda di�i 1e� e �: .� ��.�.. oh e e, rn and _ HIGH - VELOCITY HURRICANE ZONES • • ••• • • FLORIDA BUI ; • • _ J. • ; • ••• • . • •••;• • SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES•AND'REGULATIONS • 44.21R 712010 Goo; • •• •• Roof Slow 3 : 12 Ridge Vanilla on Waft m .� .. •• . •. • YOttindonliffnefte ittaulattan It►1fr Ake: FaStEDOP TYPE & ; i'I ► ► .iti, f k , s' R met 4 t ,A 40 y!'aG hap and a �►� bv 0. G fs en • r 9 = ff0 ng a • . Beek Typo: •• • .••• • • • ••• •• • • • • • • • • • • • . • • • • • • • • •• • • • • • • • • • •• - • • •• • • • • • • • • • • •'i• • ••• • ••• •' • FLORIDA BUILDING.Cp 1 vilspegnac •• • •. •• • • • •• .•• • • .• •• ••• • d HIGH VELOCITY HURRICANE ZONES rx fAt7"; 3' vi 646,11. .�• HIGH - VELOCITY HURRICANE ZONES • 44 .24R • • • • • 2410 Simon' "E 1e Wit# iga M **Mika sr gI *r, a equMt tot* 1 • weikoh4tiwittheliwit daft *idle afteithilailt : **od _ 9�e Z As" , . / ` . 9d � /a', ' ProituctA M (P �` / . � , } . M a prove p M r _- � � • �i�,(• .,�PralnctAppraval '.ii:•�1°,;; I • `• 3 Product Approval Mi ®. Maud P'Stulpaged Tile adewatioicreerope Odso bilufratratneitt omegas= 00 from Ts y, ^,,.,,,_, Product Approve' m 'fit Ue fer >:e0 *VA* .;3.. PHIVIrak t'' i °tom 3 0 11 % fOr t. It the: e F .grAS*ttiela•er±er • e0.1 , . : ;tbod 3' 't . 4 41 1* * � 1 . WOO " .�`$:, X • ,tVs ----�' -�— �.. ProdactAppro�a F' "r...,_Yc�S_..,.,°"r.]€ 4i3 ,r... � 1' WI; -.,..t Produc'tApproval ::, ....,s •tj`• 411 * "..e - civt O : Ft:4c product Approval Whoiiethadabibbiiiiittion 'Product •va1 Mad 1�a •. c • • 111191H1110MIL71,ik `' • ! • . , -• ,: _ �• ,�''. ••.. • • • • • • • • e • • • ;•: j• • ri •••• • • • • •• • •.•.• +'•.: •'••. •,.•• • • ••• • • • • . ••• • '•• •••• • • • a • • • • • • • • •• • • : • •• ', • • • • • • • • 'i' • • • • •• •• • • •• •• .• . ••• • • • ••••• • `FLORIDAlLUINCIf•tE - RESIDENTIAL M I A M I�DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polystick P, Basik, LR/IRX, TU, TU Plus, TU Polyester and MU Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSpEC1ipl'!: cow of thig entire NOA shall be provided to the user by the manufacturer or its distributors rind %riaa bE gualable for inspection at the job site at the request of the Building Official. • • ••• • • • • • •• This NOA revises NOA No. 06- 0505.01 and consists of pages 1 throu _a 6. The submitted documentation was reviewed by Jorge L. Acebo. . ... • ... .. • • • • • • • • • • • • • • • •• • • • • • • • • • •• • • • •• • • • • • • • • • • • • • • • • • • • • •• •• MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOA No.: 07- 1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 1 of 6 ROOFING COMPONENT APPROVAL Categor_: ,Sub- Category: Material: PRODUCTS DESCRIPTION: Test Product Dimensions Specification Polystick P Roll: underlayment 75' x 3' 40 mils thick Polystick Basik Roll: underlayment 65'8" x 3'3- 3 4" 60 mils thick Polystick IR/IRX Roll: underlayment 65'8" x 3'3- 3 / 8 " 80 mils thick Polystick TU underlayment Polystick TU Plus underlayment (Facer of Membrane Labeled in Orange or Black Ink) Polystick TU Polyester Polystick MU underlayment •• ••• • • • • • • • • ••• • • •• • • • • • • • • • • • • • • • • • • • • • • • •• • • •• • • • • • • • •.. • • • • • • • • • • • . • ••• • • • ••• Roll: 32' 10" x 3'3 100 mils thick Roll: 65'8" x 3'3 80 mils thick Roll: 32' 10" x 3'3 -3/8" 130 mils thick Roll: 65'8" x 3'3 80 mils thick • • • •• • • •• • • • •• • • • • • • •• • • • • • • • • • • • • • • • • • • • • •. .• Roofing Underlayment SBS , APP Self - Adhering Modified Bitumen Product Description ASTM D 1970 A polyethylene top surface, self- adhering, SBS polymer modified bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. ASTM D 1970 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use an underlayment for metal roofing. TAS 103 and A fine granular /sand top surface self - adhering, ASTM D 1970 APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. TAS 103 and A heavy granuled surface self adhering, APP ASTM D 1970 polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. TAS 103 and A non - wicking fabric surfaced, self - adhering, ASTM D 1970 APP polymer modified, fiberglass reinforced with a high strength polyester fabric, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. TAS 103 A rubberized asphalt waterproofing membrane, glass - fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. TAS 103 and A non - wicking fabric surfaced, self - adhering, ASTM D 1970 APP polymer modified, fiberglass reinforced, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. NOA No.: 07- 1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 2 of 6 EVIDENCE SUBMITTED: Test Agency Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated, new construction Base Sheet: One or more plies of ASTM D 226 Type lI or ASTM D 2626 or Polyprotector UDL or Polyprotector UDL AS. Fastening: Nails and tin caps 12" grid, 6" o.c. at laps. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-'h" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current .rro t �oitroJ NQtike otAcceptance. • • • • • • • • • 8. • ivtagitipt qr ctrAnsIhall be initially taped with a 6" piece of underlayment. The flashing • •taps shaft kre lSi s 1 *i plate and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • •• • • • • •• • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • • • 0 •• • • • 0 •• • • Test Identifier Test Name/Renort Date #11756.04.01 -1 TAS 103 04/27/01 #11756.08.01 -1 ASTM D 1970 08/14/01 #02202.08.05 TAS 103 08/29/05 #P5110.08.07 TAS 103 08/29/07 PRI01111 ASTM D 4977 04/08/02 PUSA - 005-02 -01 ASTM D 4977 01/31/02 PUSA -018 -02 -01 ASTM D 2523 07/14/03 PUSA -035 -02 -01 TAS 103 09/29/06 PUSA -033 -02 -01 ASTM D 1970 01/12/06 JX20H7A ASTM D 4798 04/01/08 ASTM G 155 NOA No.: 07. 1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 3 of 6 Tile Profile Polystick IR/IRX Polystick MU Polystick TU, TU Plus TU Polyester Flat Tile 5:12 No limitation No limitation Profiled Tile Prohibited 5:12 No limitation GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick P, Basik and IR/IRX may be used in asphaltic shingles, wood shakes and shingles, non- structural metal roofing, and quarry slate roof assemblies. Polystick P and Basik shall not be used as roof tile underlayment. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick membranes shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polystick P, Basik, IR/IRX, TU, TU Polyester and MU Underlayments shall not be left exposed as a temporary roof for longer than 30 days after application. Polystick TU Plus shall not be left exposed as a temporary roof for longer than 180 days after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice. Polystick TU, TU Plus and MU may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR/IRX is limited to mechanically fastened roof tile applications. Polystick TU Polyester may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as described below: The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. 9. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass Tile loading detail for loading procedure. 0. 0 • • • • • • • • • • • • • • • • • • • • •• • • • • • • • •• • • • • • • • • •• .. • • ••• • • • • • • • • • •• • • • •• • • • 0 • • • • • • • • •• • 6 Roofing Tiles 16 Max. Per Stack) 12 NOA No.: 07-1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 4 of 6 GENERAL LIMITATTIONS: (CONTINUED) 10. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick P, Basik, IR/IRX, TU, TU Plus, TU Polyester & MU may be used with any approved roof covering Notice of Acceptance listing Polystick P, Basik, IR/IRX, TU, TU Plus, TU Polyester & MU as a component part of an assembly in the Notice of Acceptance. If Polystick P, Basile, IR/1RX, TU, TU Plus, TU Polyester & MU is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus and Polystick MU should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus and Polystick MU should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB • Has qg cepnejcPQlyAlass•PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Plashi$g jnlAt:Mte - Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide • 42111i4od R P1as'hi*g Ackeitive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick Basik. 5..•. At pximn of tithes pep stack are allowed when loading tile on the underlayments. Refer to the PojyglgsQTtle 1:oaajjng juijletines. •• •• •• •• •••• • • • • • • • • • • • • • • •• •• • •• • • • • • • • •• • • • • • • • • • • • • • •• •• NOA No.: 07- 1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 5 of 6 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6 1 4 "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty Eight (48) Hours. 8. Polystick TU Plus, Polystick MU may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self- adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1(800) 894 -4563. 13. Polyglass offers a 10 year Limited Material Warranty on all properly installed Polystick self - adhered underlayments. Warranty must be requested and registered by Polyglass to be in force. 14. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 15. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. ••••••• • •. •• • • • • • • • • • •• ••• •• • • • •• • ••• • •e• •• • • • • • • • • • • • • • • • • •• • • • • • • • • • • • •• • • •• • • • • • • • • • • • • • • • • • • •• •• ••• • • • • • • • ••• • • • • • • • • • • • It •• •• • ••• • • END OF THIS ACCEPTANCE NOA No.: 07-1025.10 Expiration Date: 09 /13/11 Approval Date: 04/10/08 Page 6 of 6 MIAMI�DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) MonierLifetile, LLC 200 Story Road Lake Wales, FL 33853 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 (Shake, Slate & Split Shake) Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. IN$PEC'l qN: A. Cap f of tI3iS'hntire NOA shall be provided to the user by the manufacturer or its disTributoura aid shill auaitable for inspection at the job site at the request of the Building Official. •• •.•• • •.• • • . • • • • •• This revises NOA# 07 -0228.03 and consists of pages 1 through 7. ntat The submitted documentation was reviewed by Alex Tigera. . ... . ... .. • • • • .. • • .. • .. . .. . . • • • • • • • • • • . .. • • • • • • • • • 0•• • • • • • • • • • • • • .. . . • • • .. .. ... • • • 0 .. • • MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOA No.: 07- 0711.03 Expiration Date: 04/26/12 Approval Date: 09 /07/07 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Sub - Category: Material: Roofing Flat Profile Roofing Tiles Concrete SCOPE: This new NOA approves a system using MonierLifetile Saxony 900 (Shake, Slate & Split Shake) Concrete Roof Tile, as manufactured MonierLifetile LLC and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions MonierLifetile LLC 1= 17" Saxony 900 w = 13" 1 -5/32" thick Slate 1- 9/32" thick Shake & Split Shake Trim Pieces 1= varies w = varies varying thickness SUBMITTED EVIDENCE: Test Agency Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. • • • • The'Cent6f for Engineering, Inc. • ... • • • • • • • • • • • .. • • • . • • . .. • • .. • • • • • • • • . • • • .. • • • • • • • • • ... • • • • • • • • • • • • .. .. • • • .. .. 0 00 • • • 000 • • Test Identifier 7161 -03 Appendix III 94-084 94 -060A 25- 7183 -6 25- 7183 -5 Test Specifi TAS 112 TAS 112 Product Description Flat profile, interlocking, high- pressure extruded concrete roof tile equipped with two nail holes. For direct deck or battened nail -on, mortar set or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report Date Static Uplift Testing Dec. 1991 PA 102 & PA 102(A) Static Uplift Testing May 1994 PA 101 (Mortar Set) Static Uplift Testing March, 1994 PA 101 (Adhesive Set) Static Uplift Testing Feb. 1995 PA 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing Feb. 1995 PA 102 (2 Quik -Drive Screws, Battens) NOA No.: 07-0711.03 Expiration Date: 04/26/12 Approval Date: 09 /07/07 Page 2 of 7 The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Atlanta Testing & Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Nutting Engineers •• •• • • • • • • . • • • • • • • •. • •• •• • • • •. • ••• • •.• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • T 1'' • • 1 1!! • • • • ` • • • rrpV • ••• • • • • • •• •• • • ••• • • • • Test Agency • • • • • • . • •• • • • • • • • • • • • • • • • • • • •• •• Test Identifier 25- 7214 -1 25- 7214 -5 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 PO402 Project No. 307025 Test #MDC -77 R1.894 R2.894 R3.894 520109 -1 520111-4 520191 -1 Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Calculations Evaluation Calculations 130 Test Name/Reaort Static Uplift Testing PA 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 Physical Properties PA 112 Static Uplift Testing PA 101 Static Uplift Testing PA 101 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 25 -7183 Aerodynamic Multipliers Two Patty Adhesive Set System Restoring Moments Due to Gravity TAS 112 Date March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Aug. 1994 Dec. 1998 March 1999 February 1996 April 1996 December 1996 March 1995 January 2007 April 1999 February 2007 January 2007 NOA No.: 07- 0711.03 Expiration Date: 0426/12 Approval Date: 09/07/07 Page 3 of 7 Table 3: Restoring Moments due to Gravity - M (ft-Ibf) Tile 2 ":12" 3 ":12" 1 4"• 5 ":12" 6 ":12" 7 ":12" or 0.313 Profile greater Saxony Battens Direct Battens Direct Battens irect ttens Direct Battens Direct Battens Direct 900 •• ••• • •Deck • • •• Deck ; Deck Deck Deck Deck Slate, : Shake & ` t • . as • • • • • • : 1.0$ R.03 , : •: • .f 6.97 7.91 E 6.82 7.74 6.65 7.55 6.46 7.34 Split '• ii • • • • • •• ° Shake / Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight W (Ibf) Length -I (ft) Width -w (ft) MonierLifetile Saxony 900 Slate, Shake & Split Shake 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - I ft Tile X (ft3) A ( Profile Batten Application Direct Deck Application MonierLifetile Saxony 900 0.289 0.313 Slate, Shake & Split Shake 1 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3. Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 4. Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 5. 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 6. This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. INSTALLATION: 1. MonierLifetile Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 2. Data For Attachment Calculations • .•• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • ., T Ci • • • • . •• •• • • • • • • •• • • • • • • • • • .•. • • • • • • • • • • • • • • • •• • •• • •• • •• • • ••• • • • ••• • • NOA No.: 07- 0711.03 Expiration Date: 04/26/12 Approval Date: 09 /07/07 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibt) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Saxony 900 Slate, Shake & Split Shake 2 -10d Ring Shank Nails 30.9 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2 -10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 . #8 Screw 30.8 30.8 18.2 2 . #8 Screws _ 51.7 51.7 24.4 1 -10d Smooth or Screw Shank Nail (Feld Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Feld Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 Table 5: Attachment Resistance Expressed as a Moment Mf (ft -Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance MonierLifetile Saxony 900 Slate, Shake & Split Shake Adhesive 31.3 1 See manufactures component approval for installation requirements. 2 Dow Chemical TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance MonierLifetile Saxony 900 Slate, Shake & S lit Shake Polyfoam PolyProw 1 10.9' Po oam Po Pre'" ` 40.4 3 Large paddy placement of 45 grams of PolyProT"". ∎.- 4 '• Medium , ad • lacement of 24 s rams of Pol Prom' Table 5B: Attachment Resistance Expressed as a Moment - M for Mortar Set Systems Tile .....: PC0fJip, : : ." Tile Application Mortar Set' Attachment Resistance 43.9 MbrilerLitatile544 atlit '. Slatd, Slalc4 &aill@SKaIQa ... 5. Tile -Tite Roof Tile Mortar ... • ••• • • • • • • • • • • • • • • • • • • • • • • • .. ••rc;,. • • .. • • .. .. • • • • • • ... • . • • • • • • • ••• • • • • • • • • • • • • . .. • • • .. .. . .. • • • ... • • NOA No.: 07 0711.03 Expiration Date: 04/26/12 Approval Date: 09 /07/07 Page5of7 LABELING: All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Control Approved ". MONIERLIFETILE LLC, SAXONY 900 TfLE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NAIL HOLES 17 •• ••• • • • • . • • 0 • • • 0 • • •• • • ••• ▪ • • MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SLATE MODEL) • ••. • •• •• 0 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • i % • • • • • • • .• • • • • • • • • • •.• • 0 • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • •, PROFILE DRAWING WATERLOCK 13" 1 5/32 ° (slate) 1 9/32 " (shake) OVERLAY NOA No.: 07- 0711.03 Expiration Date: 04/26/12 Approval Date: 09 /07/07 Page6of7 PROFILE DRAWING MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SPLIT SHAKE MODEL) • • • • • • Mrm�rrAai st rmrr.E C ► �rnNnr I f fl CONCRETE ROOF TILE (SHAKE MODEL) • ' ' ' FiND OF THIS ACCEPTANCE •• • ..• •• • • • •• • •. ••• • ••. • • • • • • • •• • • • • • • •• • • • • • • • • • • • • • • •. • • • • • yT (ii • • • • J ■ ^ 0 • • ••• • • 1011P • • • • • • • ••• • . • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • NOA No.: 07- 0711.03 Expiration Date: 04/26/12 Approval Date: 09 /07/07 Page 7 of 7 MIA M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committce to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® AH160 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.01- 0521.02 and consists of pages 1 through 7 The submitted documentation was reviewed by JFrge L. Acebo. • • • • • • • •• ••• • • • • • •• • • • • • • • • •• ••• •• • • • •• • ••• • • • • • • • • • • • •• • • ••• • • • • • • • • • • • • ••• • • • • • • • •• •• • • ••• • • • ••• • • • • ••• •• • • • • •• • • • • • • • • • • • • • • • • • •• •• • • MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOA No.: 06-0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 1 of 7 ROOFING ASSEMBLY APPROVAL: Category: Sub Category: Materials: SCOPE: This approves Polypro® A11160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® All 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Polypro® AH 160 N/A Foampro® RTF1000 N/A FroPack® 30 & 100 N/A PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Note: The physical properties listed above are presented as typical average values as determined . h pceepted.ASTM testimethods and are subject to normal manufacturing variation. • • • • •• ••• •• • • • •• • • • • • • • . • • • • • • • • • • • • • • • • • • ... • • • • • • • .. • • .. • • • • • • • • • • • • • • • • • • • . . . • • • Roofing Roof tile adhesive Polyurethane Test Specifications TAS 101 Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment Results 1.6 Ibs. /ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft 3.1 Perm / Inch +0.07% Volume Change @ -40 F., 2 weeks +6.0% Volume Change @ 158°F., 100% Humidity, 2 weeks 86% NOA No.: 06-0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories N13 -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739 -062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® A11160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro AH160 roof tile adhesive with 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. • • • • their tile assemblies shall test in accordance with TAS 101. ••• ••• • • • • • IV W 1 • ? • . •• ••• •• • • -,• MS • • •• •• • • • • • • • • • • •• • • • • • • • • • • • • • • • • ••• • • • • ••• • • • • • • • • • • • • • ••. • • • • • • • • • • • • • • .. .• • • • •. •• 800 • • • 0 • • NOA No.: 06-0201.02 Expiration Date: 05 /10/11 Approval Date: 04/13/06 Page 3 of 7 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan 24 N/A N/A Flat, Low, High Profiles #2 Flat, Low, High Profiles #3 8 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polyproo AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polyproo AH160 roof tile adhesive and its components shall be installed in accordance with Roofmg Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro+? AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® A11160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. • • • • LABELING: All Polypro® AH 160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As regyirgdby .the Bteildieg.Offteial or applicable building code in order to properly evaluate the inst lation of t1s+s st®m• • • • ••••••:•• • • •••••••.• •• ••• •• • • • •• • ••• • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • •• • • • • • • ••S • • • ••• •• • • • • •• • • • • • • • • • • • • • • • • • NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 4 of 7 1 1 , Nall Uvough plastic affluent Uadedaymem • • • • •• • • • • • • • • • • • • • • • • • • • •• • • • • • • • ••• •• • • • • • • • • • • •• • • • • • • • • •. • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • •• • • • • • • • • • • ••• • • ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY top portion of the save course war Ma. Matto wand come of pan tiles. Ensure eava end of paa and cover tiles ere Rush at nave tlne. Eavadouse Weeph& Fascia (mortar shown) tag through plastic named Optional Potd-up Qatar on edges 1es b NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 5 of 7 l 1 1 I S ... • • • • • .. • • • • • .. ... . • . • . ... • • • • • • • • • • • .. • • • • .. • • • • .. • • • • • • • • ... • • • • ••• • • • • • • • • • • . • • • • • • • • • • . . . • • • 0 . . 000 • • • 0 • • ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY NOA No.: 06- 0201.02 Expiration Date: 05 /10 /11 Approval Date: 04/13/06 Page 6 of 7 Nall through plastic cement PA n.x 3 In. Side tidy on underiayment Single paddy on top of tile ..... • •• • • . • •• • • END OF THIS ACCEPTANCE l '� • • • • • • • • • a� • • • • • • • • • • •• • • • • '1 • • • • • • • • • • • • • • ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• • • • • ••• • • ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Ewe Comae Single paddy under tile Single paddy between the 2hi.x7 in. medium size paddy ease course only Siigle paddy between tile Eave Closure 21a x 7 In. medium eke paddy eave course only Fascia NOA No.: 06- 0201.02 Expiration Date: 05 /10/11 Approval Date: 04 /13/06 Page 7 of 7 gi Strip and Removal ❑ Glove Bag ❑ Bulldozer ❑ Wrecking Ball ❑ Wet Method ❑ Dry Method ❑ Explode ❑ Burn Down OTHER: II. TYPE;OF NOTICE (CHECK ONE ONLY): FA ORIGINAL ❑ REVISED TYPE OF PROJECT (CHECK ONE ONLY): ❑ DEMOLITION ❑ RENOVATION ❑ YES IF DEMOLITION, IS IT AN ORDERED DEMOLITION? IF RENOVATION: IS IT AN EMERGENCY RENOVATION OPERATION? ❑ /O File # IS IT A PLANNED RENOVATION OPERATION? C� YES ❑ NO Process # I. Facility Name ] �.t.. F _- ! a . C gee- / Address J/3i 1 2 ''''d Art City 07 d ea t er! �,�hrrore..r* i State f l i Zip 1 / 4 ! County , if Mt; Site Consultant Inspecting Site Building Size 3 0� C (Square Feet) # of Floors / Building Age in Years Prior Use: ❑ SchooVCollege/University ❑ Residence ❑ Small Business Other Present Use: 'I SchooVCollege/University ❑ Residence ❑ Small Business Other Facility Owner ,66,, ( /'a/ta./ „r $ r �F, Phone ( ) Address `° d 4 0 C Air NOTICE OF DEMOLITION OR ASBESTOS RENOVATION City . ! aj:t a Shore 1 State c/ Zip / 3 / 4 a / III. Contractor's Name :. 45,, r7y £v/ Z. 0..d S ek 1 f Phone lit) 7fr1 ?1/ Address /Ire, /' Si. 7 ,�tl A, ,I' �►. City a�� .. s`. State Fi. Zip 3 30 S q Is the contractor exempt from licensure under section 469.002(4), F.S.? ❑ YES ❑ NO IV. Scheduled Dates: (Notice must be po , arked 10 workin days before the project start date) Asbestos Removal ( mm/dd/yy) Start J 4 Finish: Lf 1 Demo/Renovation (mm/dd/yy) Start: 0f / Finish: b1 ° in 1 V. Description of planned demolition or r` novation work to �be rfo ed nd ethods to be employed, including demolition o renovation techniques to be used and description of affected facility components. 0®a �5r ea /y itiOd Pro dures to be Used (Check All That Apply): Florida Department of Environmental Protection Division of Air Resource Management VI. Procedures for Unexpected RACM: ClclUbfk'. Q VII. Asbestos Waste Transporter. Name .504,T /ice,4 ?' rfe S Tc. r 4L C. Phone cove)-8042- 7 3 1° Address 7 io / 'I/ /l'hr'a T 1 o City 0.67.,0 6C+.se4 VIII. Waste Disposal Site: Name S�+ssl - '+a.� * s p ^ e .S +' 5 TG+ S Li. C Address 7 FU �d lira +rte /20,. /20,. City Th IX. RACM or ACM: Procedure, including analytical methods, employed to detect the presence of RACM and Categ ry ,� t� a aitI Nn. Ain QUAL.I�F Ia'1ANIAGEMCMT DIVISIOM square feet cementitious materikis is to c ertify that the required square feet resilient flooli4 ification(s) Regarding asbestos have been square feet asphalt roofing submit e. ompliance with Amount of RACM or ACM* square feet surfacing material linear feet pipe cubic feet of RACM off facility components *Identify and fecal nur:ac nggmaterial and►other materials as applicable: • • • • • • • • • certify that the above information is correct and that an individual trained in the provisions of this regulation (40 C FR Part 61, Subpart M) will be on- site during the demolition or renovation and evidence that the required training has been accomplished by this person will be available for inspection dud o met kuArrtshot{ • • •4• ••• ••• • nail- ;.lam; .. • • • (Print Na of- • tier/ 161 01 -158 4/10 • • • (Sign;'ture of Oawt perator • • • • • • • • • • s • • • • . .. - •••. • • A DERM USE ONLY ” • • • so. *Po D t RECeived ••• s • • • „ State df Zip V 7 State 6' Zip "3 7 7 �'612o/o (Date NO NO ❑ CANCELLATION ROOFING ID # DISTRIBUTION: White —DERM Yellow— Applicant Pink — Reserve Gold— Reserve COUNTY Miami -Dade DERM Quality Management Division 701 N.W. 1st Court, 2nd Floor Miami, Florida 33136 ❑ COURTESY MIAMFDA13 (Contact phone #) NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INFECTION PERMIT NO. STATE OF FLORIDA COUNTY OF MIAMi -DADE: TAX FOLIO NO. 11-2136-000-0050 THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided In this Notice of Commencement 1. Legal description of property and street/address: 11300 NE 2 AVE MIAMI SHORES 36 52 4140 AC SE1M OF NEII4 LESS E35FT & LESS W4OFT LOT SIZE 1740400 SQUARE FEET 2. Description of improvement; Lavoie 1111111111111111 11111111111111111111111111 GFI+i 2010R0613321 OR Bk 27415 Ps 4959; (fps) RECORDED 09/10/2010 109:34 :107 HARVEY RUVINr CLERK OF COURT MIAMI -DADE COUNTY ► FLORIDA LAST PAGE Space above reserved for use of recording office 3. Owner(s) name and address: BARRY UNIVERSITY, INC. 11300 NE 2ND AVE MIAMI FL 33161 Interest in property: Name and address of fee simple titleholder: 4. Contractor's name, address and phone number INFiNITY ROOFING AND SHEET METAL. NC. 1150 SW 10TH AVE STE 201W POMPANO BEACH FL 33069 5. Surety: (Payment bond required by owner from contractor, If any) Name, address and phone number: NA Amount of bond $ 6. Lender's name and address: NA 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1 Xa)7., Florida Statutes, Name, address and phone number. NA 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number: NA 9. Expiration date of this Notice of (the expiration date is 1 year from the date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE 11-E FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WiTH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR p OF COMMENCEMENT. Y Authorized Officer/Director/Partner/Manager ec J k y !1 /b,'tO(4 B 1 I SO 1 .4/ Ill Av? STE 201 w ,ft fn ire eeec j' j 1f' :? Print Name 3 3069 A .Q /Ice Title/Office Signature(s) of By Print Name Title/Office 4 a id STATE OF FLORIDA COUNTY OF MIAMI -DADE B e foreg�gi,�$ instrum t� was acknowledged before me this � s � day of IIL CI &V . 24 2016 ,A individually, or ❑ as for Personally known, or ❑ produced the following type of Identificall Signature of Notary Punic: • • ••• • • • • • • • Print Name: • ($ =o _ P " C State 0f Florida • • Jeffry J Yao ▪ • • MY Commission DD613542 ALL; . .�l.�,i.l.�.:.1s i :, _i.0 i.� ���{(1 L'...��_�!. .�!1i � s :. .�1T uncle pe " that! have read the forego 1+P Expires 1111212010 .. that the facts stated in It are true, to the best of my knowledge an n e Sn le)of gr • • • • 1231 -52 PA6E3 11■17 •••• ••••••• • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 4:Authorized Officer/Direotor/Partner/Manager who signed above: • • • • By STATE OF FLOi M, couN B U Ot DX =Z 1 HEREBY CERTIFY Mgt 0i43 is c' u& ; a y 6' tin rn icr�. LEF;K, a MARVE 5y A D 2V /0 Ce`ui? )' D.C.