Loading...
EL-10-22251 FIRE ALARM LEGEND SYMBOL DESCRIPTION MANUFACTURER MODEL 1/8" = 1' -0" FIRE ALARM CONTROL PANEL BOSCH FPD -7024 FACPI REMOTE ANNUNCIATOR BOSCH FMR -7033 ANN 5495 DISTRIBUTED POWER MODULE SILENT KNIGHT 5495 FIRE TRANSCEIVER AES— lntelliNet 7788F RADIO SD PHOTOELECTRIC SMOKE DETECTOR BOSCH D263 CONVENTIONAL PULL STATION WEATHER PROOF FIRE —LITE BG -12LOB WITH WP BACK BOX (WBB) P wp H 1 HORN SYSTEM SENSOR HW HORN /STROBE (75cd) WEATHER PROOF SYSTEM SENSOR P2RK WITH WP BACK BOX (SA —WBB) HS 1 Wp M 4 MINI HORN SYSTEM SENSOR MHR FIRE ALARM NOTES 1 —FIRE ALARM SYSTEM SHALL BE U.L LISTED AND NFPA 72 APPROVED AND COMPATIBLE. 2 —RISER INTERCONNECTIONS ARE DIAGRAMMATIC ONLY. 3 —TOTAL ACTIVE AREA: 21,556 SQ. FT. 4 —FIRE ALARM SYSTEM TO BE "POWER LIMITED ". 5 —THE INSTALLATION SHALL COMPLY WITH NFPA 70 CHAPTER 760. 6 —ALL WIRING AND CONDUIT SIZE SHALL BE IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION, LOCAL CODES AND NFPA. 7 —ALL CONDUCTORS SHALL BE SOLID OR STRANDED COPPER. 8— MAXIMUM CONDUIT FILLS TO BE 40 %. MINIMUM RACEWAY SIZE 3 ". 9— SYSTEM SHALL BE GROUNDED ACCORDING TO MANUFACTURER SPECIFICATION AND NEC ARTICLE 250. 10—ALL FIRE WALL PENETRATION SHALL BE MADE WITH APPROVED (NEC) ELECTRICAL TUBING AND SEALED WITH A U.L. LISTED FIRE STOPPER. (SEE FIRE STOP DETAIL). 11 -TiiE 120V AC POWER FEED FOR THE FIRE PANEL MUST BE FROM A DEDICATED CIRCUIT AND THE BREAKER MUST BE IDENTIFIED FIRE ALARM CIRCUIT AND HAVE A LOCK ON IT 12— VISUAL ALARM PER ANSI A117.1, 4.26, AND ADA APPROVED. WALL MOUNTS 80" A.F.F. TO BOTTOM OF STROBE LENS. 13 —ALL NEW WIRING INSTALLED IN DUCTS, PLENUMS AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP, AS PER NEC (NATIONAL ELECTRIC CODE) ARTICLE 760 -61. 14 —ALL N.A.C. WIRING SHALL BE CLASS "B" (STYLE "Y"). INITIATING CIRCUIT WIRING SHALL BE CLASS "B ". 15 —HORN /STROBES SHALL BE LOCATED AS PER NFPA 72, CHAPTER 7. 16— STROBE LIGHT CIRCUITS SHALL BE SYNCHRONIZED AT 1HZ PER ADA AND NFPA 72. 17— UNLESS OTHERWISE NOTED ALL CEILING HEIGHTS DO NOT EXCEED 10' -0" AND ALL CEILINGS ARE FLAT. 18— FURNITURE AND EQUIPMENT SHALL NOT EXCEED 72" IN HEIGHT WHERE PLACED ALONG THE PATH OF VISUAL SIGNALS. 19— AUDIBLE DEVICES SHALL BE MINIMUM 75db IN SLEEPING AREAS. 20 —NEW SYSTEM IS CLASSIFIED AS CERTIFICATED FOR CENTRAL STATION SERVICE PER NFPA 72 8.2. 21 —THE SYSTEM SHALL HAVE BATTERY BACK UP FOR 24 HRS IN STANDBY MODE AND 5 MINUTES IN ALARM. 22 —NEW FIRE ALARM DEVICES TO BE COMPATIBLE WITH THE NEW CONTROL PANEL AND RATED FOR FIRE USE. 23 —THE F.A.C.P, POWER BOOSTER AND RADIO ARE INSTALLED IN CLIMATE CONTROLLED ENVIRONMENT MEETING THE REQUIREMENTS OF NFPA 72,4.4.4.1. 24 —THE NEW F.A.C.P FPD -7024 SUPPORT: — UP TO 255 ADDRESSABLE POINTS AND 58 PROGRAMMABLE RELAYS OUTPUTS. — FOUR DETECTOR ZONES (EXPANDABLE TO EIGHT); UP TO 20 TWO WIRE DETECTORS PER ZONE. — TWO NAGS ON BOARD WITH INTERNAL 24VDC, 4 AMP NAC POWER SUPPLY. SEQUENCE OF OPERATION: 1. —FIRE ALARM INITIATION DEVICES: A.— MANUAL FIRE ALARM PULL STATIONS ACTIVATION OF ANY FIRE ALARM PULL STATION SHALL CAUSE THE FOLLOWING ACTION AND INDICATIONS: — ACTIVATE THE AUDIBLE AND VISUAL SIGNAL THROUGHOUT THE FACIUTY. — ACTIVATE THE ALARM LIGHT AND A DISTINCTIVE SOUND AT THE FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR. — INDICATE THE LOCATION OF THE PULL STATION BY DISPLAYING IN ENGLISH THE ALARMED DEVICE ON THE FACP ALPHANUMERIC DISPLAY AND REMOTE ANNUNCIATOR. — TRANSMITS A FIRE ALARM SIGNAL TO THE DESIGNATED LISTED CENTRAL STATION BY WAY OF DIGITAL ALARM COMMUNICATOR (RADIO). B.— AUTOMATIC FIRE DETECTORS (SMOKE DETECTOR) ACTIVATION OF ANY AUTOMATIC FIRE DETECTION DEVICE SHALL CAUSE THE FOLLOWING ACTION AND INDICATIONS: — ACTIVATE THE AUDIBLE AND VISUAL SIGNAL THROUGHOUT THE FACIUTY. — ACTIVATE THE ALARM UGHT AND SOUNDER AT THE FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR. — INDICATE THE LOCATION OF THE AUTOMATIC DETECTOR BY DISPLAYING IN ENGLISH, THE ALARMED DEVICE ON THE FACP ALPHANUMERIC DISPLAY AND REMOTE ANNUNCIATOR. — TRANSMITS A FIRE ALARM SIGNAL TO THE DESIGNATED LISTED CENTRAL STATION BY WAY OF DIGITAL ALARM COMMUNICATOR (RADIO). NOTE: NOTIFICATION APPLIANCES WILL NOT BE ACTIVATED. 2.— TROUBLE SIGNALS. THE OCCURRENCE OF ANY TROUBLE IN THE SYSTEM SHALL CAUSE THE FOLLOWING ACTION AND INDICATIONS: — ACTIVATE THE TROUBLE UGHT AND A DISTINCTIVE TROUBLE SOUND AT THE FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR. — DISPLAY A TROUBLE DESCRIPTION ON THE FACP ALPHANUMERIC DISPLAY AND REMOTE ANNUNCIATOR. — TRANSMITS A TROUBLE SIGNAL TO THE DESIGNATED LISTED CENTRAL STATION BY WAY OF DIGITAL ALARM COMMUNICATOR (RADIO). NOTE: TROUBLE SIGNALS AND THEIR RESTORATION TO NORMAL SHALL BE INDICATED WITHIN 200 SECONDS. THE MAXIMUM TIME PERIOD FROM ACTUATION OF THE INITIATING DEVICE UNTIL INITIATION OF ALL RELATED FUNCTIONS AS LISTED ABOVE SHALL BE TEN SECONDS. BEDROOM T BEDROOM BEDROOM ,A /C LIVING ROOM P1.3.2 COMMON ROOF BEDROOM BEDROOM BATH. BAT, BEDROOM BEDROOM BEDROOM WP P 22.1 WP HS P1.3.1 75cd PATIO BEDROOM BATH. BEDROOM BEDROOM BEDROOM <AJC UVING ROOM I P1.1.2 2 _BATH. BEDROOM 1 BEDROOM BEDROOM 11111 WP WP LIVING ROOM BEDROOM LIVING ROOM A/C BEDROOM P Z2.4 HS P1.3.3 .c 75cd PATIO DISTRIBUTED POWER MODULE SILENT KNIGHT "5495" 722 P BEDROOM BEDROOM P1.1.4 DII UVING ROOM <A /C i; BATH BEDROOM PATIO =hlP1.1.1 WP WP 75cd TAI RS Z2.3 Trffiel P1.1.3 WP WP 75cd P4 H1 PATIO 0 UTILITY RM. LOCATED BELOW THE STAIR (NOTE: THIS ROOM SHALL BE MECHANICALLY VENTILATED.) FIRE ALARM CONTROL PANEL BOSCH "FPD- 7024" FIRE TRANSCEIVER AES 7788F. REMOTE ANNUNCIATOR BOSCH "FMR- 7033" INSIDE NEMA 4X WITH CLEAR COVER. NOTE: THE REMOTE ANNUNCIATOR PANEL LOCATION IS NOT EXPOSED TO DIRECT SUNUGHT. PROVIDE MINI HORN INSIDE NEMA 4X ENCLOSURE TO INCREASE SOUND LEVEL THE REQUIREMENTS OF SECTION 11- 4.28.3 OF THE FLORIDA ACCESSIBILITY CODE ARE BEING SATISFIED BY UTILIZING THE STANDARDS OF SECTION 7.5 OF NFPA 72 FOR THE PLACEMENT OF VISIBLE NOTIFICATION DEVICES. 1 4 P Z2.5 HS P1.3.5 75cd PATIO STAIRS FIRE ALARM PLAN (FIRST FLOOR) SCALE: 1/8" = 1' -0" THIS IS AN EXISTING 2 STORY NON- SPRINKLED BUILDING PATIO 0 PATIO Z2 7 P1.2.1 r 'tp 75cd WP WP STAI R ZONE #2 EA� P1.2.3 1)N 1 P 75cd WP WP PATIO 2 P1.2.2 C BEDROOM LIVING ROOM paEmni bi DEC 1 6 2010 nift Gee ZZZS Miami Shores Village ,t Jlt,ll .IMPROVED TONING DEPT 3LDG DEPT DATE CT l C) COMPLIANCE WITH ALL FEDERAL ;IAI I AND (;C)UN1Y RULES AND REGULATIONS BEDROOM I P1.2.4 LIVING ROOM SCOPE OF WORK: 1. FURNISH AND INSTALL NEW FIRE ALARM SYSTEM AS FOLLOWS: QTY DESCRIPTION 1 FIRE ALARM CONTROL PANEL BOSCH 1 DISTRIBUTED POWER MODULE SILENT KNIGHT 1 REMOTE ANNUNCIATOR BOSCH W/ NEMA 4X 1 FIRE TRANSCEIVER AES 1 SMOKE DETECTOR BOSCH 16 PULL STATION WEATHER PROOF FIRE —LITE 12 HORN /STROBE WEATHER PROOF SYSTEM SENSOR 16 HORN SYSTEM SENSOR 1 MINI HORN SYSTEM SENSOR CN [ MIAMI-DADE COUNTY FIRE DEPARTMJN FIRE ALARM SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 72; 70;101• 50 STATE SECURITY SERVICE, INC. 1125 N.E. 125th STREET North Miami, FL 33161 TEL: (305)891 -7000 EF #0000818 REVISIONS BARRY UNIVERSITY DOSS HALL 11300 N.E. 2nd AVENUE MIAMI SHORES, FLORIDA 33161 DELEGATE ENGINEER ENRIQUE PEREZ P.E. ELECTRICAL ENGINEER, FL REG. No.71404 10277 N.W. 128 TERRACE HIALEAH GARDENS, FLORIDA 33018 TEL: (786)449 -4354 Email: enrique.perez.2010«gmail.com awsoomr BLDG. PERMIT FIRE ALARM 1/ r, FIRE SUPPRESSION WATER MAIN EXT. DATE: - 2 FIRE ALARM SHALL BE A CENTRAL STATION SERVICE. A CERTIFICATE OR PLACARD SHALL BE POSTED Al FINAL INSPECTION, AS PER NFPA 72 T a/Tithe(' 4"-- ll�3y2o(u PROJECT NO.: DRAWING NO.: SCALE: 1/8" = 1' -0" DATE: 11/30/10 DRAWN BY: I.M. SHEET NO.: FA -01 01 OF 03 metacaulk. (840}231 -3345 Copyright- 2008 UMerwdsrs L.b4ratces ine. Reprinted from the 2008 Fire Resistance Oirectoly with permission from Unclerwders Laboratories. Ina www oont www.fnetacaulicoorn System No. C -A) 3D26 November 29, 1995 (Formerly System No. 269) F Rating — 2 Hr T Rating W-- 1 -1/2 Hr 3 LA SECTION A -A 1. Floor or Wall Assembly nn 41J2 irt. thick reinf I ed lightweight or normal weight (100 -150 pcf) concrete. Wall may also be constructed of any U1. Classified Concrete Blocks *. Max dlam of opening is 1/2 in.See Concrete Blocks (CAZ't) category in the Fire Resistance Directory for rashes of manufacturers. 2. Cable Max 25 pair No. 24 AWG telephone cable, polyvinyl chloride insulation and jacket materials. One cable to be centered within the flrestop system. A nom annular space of 1,/8 in. is required within the flrestop system. Cable to be rigidly supported on both sides of floor or wall assembly. 3. Fill, Void or Cavity Material* -- Caulk Caulk fill material to be forced within the annulus to max extent passible, flush with top surface of floor or with both surfaces of waif. Additional fill material to be installed such that a min 1/4 in. crown Is formed around the penetrating item on both sides of wall and floor. RECTORSEAL -- Metacauffc 950 *Bearing tike UL Classification Marking 80" A.F.F. OR 6" BELOW CEILING (WHICHEVER IS LOWER) STROBE OR HORN /STROBE 48" A.F.F. PULL STATION t ADA HEIGHT REQUIREMENTS NO SCALE ALLOWABLE AMPACITY FOR COPPER WIRES SIZE ALLOWABLE AMPACITY 18 6 16 8 14 15 12 20 10 30 FROM NEC -TABLE 310 -16 & 402 -5 BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BATH.'. BATH. - BATH. TH. BATH: LIVING ROOM LIVING ROOM LIVING ROOM LIVING ROOM A/C A/C BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM P1.3.9 H COMMON ROOF P1.3.11 WP Z3.1 BALCONY BEDROOM BEDROOM c1/4. u BEDROOM BEDROOM <A LIVING ROOM P1.1.5 2 I I f._$ATH. BEDROOM BEDROOM _ BATH. BEDROOM BEDROOM BEDROOM BALCONY Z3.2 P WP wP HS f'1 i` 3 1 WP P1 6 3T A S Z3.3 WP AC B L ONY P1.1.7' E.O.L NAC #1 (P1) TOTAL WIRE RUN 170 FEET LIVING ROOM A/C I ,,BATH BEDROOM STAIRS El 4 wPu Z3.4 BALCONY P1.3.12 H P1.3.14 FIRE ALARM PLAN (SECOND FLOOR) Alt SCALE: 1/8" = 1' -0" WP Z3.5 BALCONY WP HS I P1 .2.1 cd 3 STAIRS wPu Z3.6 BALCONY H E.O.L BEDROOM NAC#3 (P1) TOTAL WIRE RUN 267 FEET BALCONY Z3 7 wP STAIRS DRAWING NO.: pl. SCALE: 2.5 Da DATE: 11/30/10 DRAWN BY: 73cd wP ONE #3 Z3.8 E.O.L�`fIF -1 F' wP BALCONY NAC #2 (P1) TOTAL WIRE RUN 240 FEET A/l UVING ROOM FIRE ALARM � Bh INSTALL WITH NFPA 72; 70;101. MLANQ -DADS COUNT' FIRE DEPARTMENT BLDG. PERMIT FIRE ALARM FIRE SUPPRESSION WATER MAIN EXT. DATE: 2 � .,�' /12 a FIRE ALARM SHALL BE A CENTRAL STATION SERVICE. A CERTIFICATE OR PLACARD SHALL BE POSTED Al FINAL INSPECTION, AS PER NFPA 72 50 STATE SECURITY SERVICE, INC. 1125 N.E. 125th STREET North Miami, FL 33161 TEL: (305)891 -7000 EF #0000818 REVISIONS E'4 W M r4 D M w w D Q O N U_ 1--� Of) W W Cn Z OC >241 C) 0 I C4r � Fil DELEGATE ENGINEER ENRIQUE PEREZ P.E. ELECTRICAL ENGINEER, FL REG. No.71404 10277 N.W. 128 TERRACE HIALEAH GARDENS, FLORIDA 33018 TEL: (786)449 -4354 Email: enrique.perez.2010@gmail.com &-iitzleodel? 11A0/2.0/6 PROJECT NO.: DRAWING NO.: SCALE: 1/8" = 1' -0" DATE: 11/30/10 DRAWN BY: I.M. SHEET NO.: FA -02 02 OF 03 E.O.L 2C #14 FPLR IN 1/2" CONDUIT. (0.0690)p) (0.176amp) (0.069amp) (0.069amp) (0.176amp) (0.069amp) 75cd 75cd NAC #3 I'. 4. ().60 amp, °.3.0 max) I OTAL 1 RUN 267 FEET FIRST FLOOR WP GE WP 0 P1.3.14 P1.3.13 P1.3.12 P1.3.11 P1.3.10 P1.3.9 (0.069amp) (0.176amp) (0.069amp) 75cd (0.176amp) (0.069amp) 75cd (0.176amp) (0.069amp) (0.176amp) 75cd 75cd P1.3.8 P1.3.7 P1.3.6 P1.3.5 P1.3.4 P1.3.3 P1.3.2 HS P W P1.3.1 E.O.L NAC #2 �� 2C #14 FPLR IN 1/2" CONDUIT. (0.069amp) (0.176amp) (0.069amp) 75cd (0.804 amp, 3.0 max) TOTAL WIRE RUN 240 FEET aa WP D P1.2.7 P1.2.6 P1.2.5 (0.069amp) (0.176amp) (0.069amp) (0.176amp) 75cd 75cd 112 © NW P1.2.4 P1.2.3 P1.2.2 P1.2.1 E.O.L. NAC #1 (0.804 amp, 3.0 max) TOTAL WIRE RUN 170 FEET FIRE ALARM SYSTEM RISER N.T.S. 2C #14 FPLR N 1/2" CONDUIT. (0.069amp) (0.176amp) (0.069amp) 75cd V MY P1.1.7 P1.1.6 P1.1.5 (0.069amp) (0.176amp) (0.069amp) (0.176omp) 75cd 75cd HWP P1.1.4 P1.1.3 P1.1.2 P1.1.1 Fire Alarm Control Panel Bosch FPD -7024 Maximum Capacity 4 Amperes DESCRIPTION Main Board Remote Annunciator Conventional Zone #1 Conventional Zone #2 Conventional Zone #3 Conventional Zone #4 Mani Horn STANDBY CURRENT PER UNIT (Amp) 0.200 0.080 0.000 0.000 0.000 TOTAL STANDBY CURRENT (Amp) 0.200 0.080 0.000 0.000 0.000 0.000 0.000 0.280 ALARM CURRENT PER UNIT (Amp) 0.380 0.100 0.044 0.044 0.044 0.044 0.017 DO■ Q 000 1E1 NMI WI( NUN II NMI 111 RI0II QTY TOTAL ALARM CURRENT (Amp) 0.380 0.100 0.044 0.044 0.044 0.044 0.017 • ■ ■ 1 II Standby 24 1 Hours Alarm 5 1 Minutes x 1/60 1 0.0833 Hours 1 REQUIRED STANDBY TIME (HOURS) TOTAL SYSTEM STANDBY CURRENT (AMPS) REQUIRED STANDBY CAPACITY (AMP - HOURS) REQUIRED ALARM TIME (HOURS) TOTAL SYSTEM ALARM CURRENT (AMPS) REQUIRED ALARM CAPACITY (AMP - HOURS) 24 X 0.28 6.720 0.083 x 0.67 0.056 REQUIRED STANDBY CAPACITY (Am p /Hours) REQUIRED ALARM CAPACITY (AMP - HOURS) TOTAL REQUIRED CAPACITY (AMP - HOURS) OPTIONAL FACTOR OF SAFETY 6.720 0.056 6.776 x 1.2 REQUIRED BATTERY CAPACITY (AMP - HOUR) 8.131 FIRE TRANSCEIVER 7788F - /AESI OOFtPORATIQN 'ntellvet o Hann Monitodnp DESCRIPTION STANDBY CURRENT PER UNIT (Amp) QTY TOTAL STANDBY CURRENT (Am p) ALARM CURRENT PER UNIT (Amp) QTY TOTAL ALARM CURRENT (Amp) Main Board 0.175 0.175 0.175 0.800 0.800 Rs 01 €rats 9lz.T'it T5e :r6dar`y P w r SoliTtelf01 .NFP.A_7 :4.4 3- a ate'. Standby J 24 1 Hours .s °3) Alarm 15 Minutes x 1 /60 1 0.0833 Hours 1 SCALE: N.T.S DATE: 11/30/10 DRAWN BY: I.M. REQUIRED STANDBY TIME (HOURS) TOTAL SYSTEM STANDBY CURRENT (AMPS) REQUIRED STANDBY CAPACITY (AMP- HOURS) REQUIRED ALARM TIME (HOURS) TOTAL SYSTEM ALARM CURRENT (AMPS) REQUIRED ALARM CAPACITY (AMP - HOURS) 24 x 0.175 = 4.200 0.083 x 0.800 = 0.067 REQUIRED STANDBY CAPACITY ) C (Amp/Hours APACI ) REQUIRED ALARM CAPACITY (AMP- HOURS) TOTAL REQUIRED CAPACITY (AMP- HOURS) OPTIONAL FACTOR OF SAFETY REQUIRED BATTERY CAPACITY (AMP- HOUR) 4.200 + 0.067 = 4.267 x 1.2 I 5.120 II B,Al l YSLIP PL!Etx °:<. A SILENT KNIGHT "5495" DISTRIBUTED POWER MODULE LOCATED IN UTILITY ROOM. 120 /208V ELEC. PANEL W/ 2 112 & 1 #12G CU, THHN, IN 1/2" C., 20 AMP CB FIRE TRANSCEIVER AES 7788F 16 VAC, 40 VA UL LISTED CLASS II TRANSFORMER CONNECTED TO 120 /240V ELECT. PANEL W/ 2112 & 1#120 CU, THHN, IN 1/2" C., 20 AMP CB P3 RADIO ke 5495 P1 E.O.L 2C #14 FPLR IN 1/2" CONDUIT. 6 #18 TFFN IN 1/2" CONDUIT BATTERY Sc VOLTAGE DROP CALCULATIONS E.O.L ZONE 14 2 #18 TFFN IN 1/2" CONDUIT TO MONITOR RADIO ET_ - 2 #18 TFFN IN 1/2" CONDUIT. WP WP WP WP WP WP WP 11 WP E.O.L MA/ ZONE #3 Z3.1 Z3.2 Z3.3 Z3.4 Z3.5 Z3.6 Z3.7 Z3.8 WP 0 WP WP 0 WP WP 0 WP 0 WP 0 WP Z2.1 Z2.2 Z2.3 Z2.4 Z2.5 Z2.6 Z2.7 Z2.8 F.A.C.P P2 ZONE #2 E.O.L MA/ ZONE #1 (MAX. 20 TWO -WIRE DETECTORS PER ZONE) BOSCH "FPD -7024" FIRE ALARM CONTROL PANEL LOCATED IN UTILITY ROOM. 120 /208V ELEC. PANEL W/ 2 #12 & 1112G CU, THHN, IN 1/2" C., 20 AMP CB H1 2C #18 FPLR P4 V' 1 ANN. SECOND FLOOR PROVIDE MINI HORN INSIDE NEMA 4X ENCLOSURE TO INCREASE SOUND LEVEL BOSCH "FMR -7033" REMOTE ANNUNCIATOR PANEL LOCATED IN COMMON AREA GND FLOOR, PROTECTED IN NEMA 4X ENCLOSURE. 4C #18 FPLR cIN 1/2" CONDUIT. Distributed Power Module Silent Knight 5495 Maximum Capacity 6 Amperes DESCRIPTION Main Board Horn Horn/Strobe WP (75cd) STANDBY CURRENT PER UNIT (Amp) 0.075 0.000 QTY 1 16 TOTAL STANDBY CURRENT (Amp) 0.075 0.000 0.000 0.075 ALARM CURRENT PER UNIT (Amp) 0.175 0.069 0.176 QTY 1 16 12 1 TOTAL ALARM CURRENT (Amp) 0.175 1.104 2.112 3.391 Standby 1 24 1 Hours Alarm 5 1 Minutes x 1/60 1 0.0833 Hours 1 REQUIRED STANDBY TIME (HOURS) 24 TOTAL SYSTEM STANDBY CURRENT (AMPS) 0.075 REQUIRED STANDBY CAPACITY (AMP - HOURS) REQUIRED ALARM TIME (HOURS) TOTAL SYSTEM ALARM CURRENT (AMPS) 1.800 0.083 3.391 REQUIRED ALARM CAPACITY (AMP - HOURS) 0.283 REQUIRED STANDBY CAPACITY (Amp /Hours) 1.800 REQUIRED ALARM CAPACITY (AMP - HOURS) 0.283 TOTAL REQUIRED CAPACITY (AMP - HOURS) OPTIONAL FACTOR OF SAFETY 2.083 x 1.2 REQUIRED BATTERY CAPACITY (AMP - HOUR) 2.499 1 CIRCUIT CURRENT CALCULATION SILENT KNIGHT "5495" ON BOARD NAC CIRCUITS CIRCUIT NO. 1 QTY DESCRIPTION CATALOG NU BER CURRENT (mA) TOTAL (mA) 3 4 HORN /STROBE WP (75cd) HORN SYSTEM SENSOR # P2RK SYSTEM SENSOR # HW 176 528 69 276 NAC #1 TOTAL 804 CIRCUIT NO. 2 QTY 3 DESCRIPTION HORN /STROBE WP (75cd) CATALOG NU BER SYSTEM SENSOR # P2RK CURRENT (mA) 176 TOTAL (mA) 528 HORN SYSTEM SENSOR # HW 69 276 NAC#2 TOTAL CIRCUIT NO. 3 QTY 6 804 DESCRIPTION HORN /STROBE WP (75cd) CATALOG NUMBER SYSTEM SENSOR # P2RK CURRENT (mA) TOTAL (mA) 176 1056 HORN SYSTEM SENSOR # HW 69 552 NAC #3 TOTAL 1.608 CIRCUIT NO.4 SPARE ACTUAL NOTIFICATION APPLIANCES LOAD IN AMPS 3.216 FIRST FLOOR N.A.C. VOLTAGE DROP CALCULATIONS SILENT D POHT MO DISTRIBUTED POWER MODULE DC RESISTANCE FOR SOLID COPPER WIRES @ 75 DEG -C SIZE 10 OHMS PER 1000 FT. 1.21 12 1.93 14 3.07 16 4.89 18 7.77 FROM 999 NEC - APPENDIX B TABLE 8 FORMULA FOR CALCULATION OF VOLTAGE DROP IN DC 2 WIRE CIRCUITS VD= 2RXLX1 WHERE VD = DROP IN VOLTS IN THE CIRCUIT TO THE LAST DEVICE, R= RESISTANCE OF WIRE IN OHMS PER FOOT {VALUES OF RESISTANCE FOR COPPER WIRE PER TABLE ABOVE)! = CURRENT IN AMPERES, AND L= LENGTH ONE WAY OF CIRCUIT IN FEET NOTES STROBE REGULATED VOLTAGE RANGE AS PER ATTACHED SPECIFICATION SHEET IS 16 TO 33 VOLTS STARTING POINT FOR VOLTAGE DROP CALCULATIONS EQUAL 20.4 VOLTS NAC #1 Wire 14 R = 0.00307 L = 170 I = 0.804 VD = 0.84 VOLTAGE TO LAST DEVICE NAC #2 Wire 14 R = 0.00307 L = 240 1= 0.804 VD = 1.18 VOLTAGE TO LAST DEVICE NAC #3 Wire 14 R = 0.00307 L= 267 1= 1.608 VD = 2.64 VOLTAGE TO LAST DEVICE NAC #4 SPARE 19.56 19.22 17.76 INSTALLED ALARM SYSTEM TO r-- IN ACCORDANCE WL ij NFPA 72; 70; 101. E mumPDAD E COUNTY FIRE DEPARTMENT BLDG. PERMIT FIRE ALARM FIRE SUPPRESSION WATER MAIN EXT. DATE: );2. /.13/217-9 FIRE ALARM SHALL BE A CENTRAL STATION SERVICE. A CERTIFICATE OR PLACARD SHALL BE POSTED AT FINAL INSPECTION, AS PER NFPA 72 50 STATE SECURITY SERVICE, INC. 1125 N.E. 125th STREET North Miami, FL 33161 TEL: (305)891 -7000 EF #0000818 REVISIONS BARRY UNIVERSITY DOSS HALL 11300 N.E. 2nd AVENUE MIAMI SHORES, FLORIDA 33161 DELEGATE ENGINEER ENRIQUE PEREZ P.E. ELECTRICAL ENGINEER, FL REG. No.71404 10277 N.W. 128 TERRACE HIALEAH GARDENS, FLORIDA 33018 TEL: (786)449 -4354 Email: enrique.perez.2010©gmail.com &xi ect„i- et/o/2010 PROJECT NO.: DRAWING NO.: SCALE: N.T.S DATE: 11/30/10 DRAWN BY: I.M. SHEET NO.: FA -03 03 OF 03 r9 - -1 1 Mao ( 1 qjz JOB COPY MIAMI DADE FIRE RES UE . )0.0.00/10 Not Applicable Disapp Not Applicable a ISI Is MOT A PERMIT MUST PROVIDE 1 E MUNICIPAL~ INSPECTION'REOUIREMENTS AND AT THE TIME OF A FIRE INSPECTION.