Loading...
EL-05-39Electrical Permit Miami Shores Village 10050 NE 2nd Avenue Phone: 305 - 795 -2204 Permit Number: EL2005 -39 Printed: 2/17 /2005 Applicant: UNIVERSITY Owner: UNIVERSITY JOB ADDRESS: 11300 NE 2 AVE Contractor DANIEL ELECTRICAL CONTRACTORS INC Contractor's Address: 5965 NW 82 AVE Local Phone: 305/592 -8777 Parcel # Legal Description: 36 52 41 40 AC SE1 /4 OF NE1 /4 LESS E35FT & LESS W4OFT LOT SIZE 1740400 Fees: Description Amount FEE2005 -2121 Building Fee $1,376.00 FEE2005 -2122 CCF $11.40 FEE2005 -2123 Training and Education Fee $3.80 FEE2005 -2124 Technology Fee $34.40 FEE2005 -2126 Scanning Fee $6.00 Total Fees: $1,431.60 Total Feed111,431.60 Total Receipts: $0.00 Permit Status: APPROVED Permit Expiration: 7/26/2005 Construction Value: $19,000.00 Work: UPGRADE OF EXISTING GENERATOR FROM 45 KW TO 100 KW Signed: (INSPECTOR) Page 1 of 1 F:3 18 PROD In consideration of the issuance to me of this permit, 1 agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responisibility for all work done by either myself, my agent, servants or employes. Signed: (Contractor or Builder) BY: MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request Date Type Insp'n ∎00 )1 Permit No. t 1 V 5 3 Q Name I oniusifui Address fi_ "-'�_ Company D 011-et . I. Phone # 3 ° S T 7 Inspection Date A Approved L'I Correction Re- Insp'n Fee kLtsrexts-12, k Jc'\ Permit No. Nain CMC/ n1(15)1(1 Address ° T),( 9 " 1,N"J Company 1 ) s93- Type Insp'n Phone # MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305-795-2204 Building Inspection Request Date ( Pooc Inspection Date Approved Correction 171 Re-Insp'n Fee 171 If CD I C / f 1 3055926978 02/14/2005 12:01 9055926978 Fax To: k, From: S D:aniel Electrical Contractors, Inc State License # EC 0001974 Tony Gervasio, Sr., President it EC- 0002190 Fa x, I_L/X Pagers: SERVICE DEPT PAGE 01/05 Date: 49-11L46 ❑ Urgent ❑ For Review 0 Please Comment ❑ Please Reply ❑ Please Recycle If you do not receive all pages, call Vivian at ext. 137 5965 NW 82 Avenue MIAMI, FLORIDA 33166 305.592.8777 FAX: 305.592.6978 02/14/2005 12: 01 3055926978 November 22, 2004 Cummins Southeastern Power Inc. 9900 NW 77 Court Hialeah. Gardens, Fl 33016 ATTENTION: George Braun Daniel Electrical Contractors,, Inc.. State License # EC- 0001974 Tony Gervasio, Sr., President # EC- 0002190 SERVICE DEPT PAGE 04105 RE: BARRY UNIVERSITY 100 KW GENSET UPGRADE Gentlemen: We are pleased to have been. invited to prepare a proposal for, the electrical work on the above referenced project as per our site walkthrough. Our lump sum price as submitted is based on contract tennis being those in the Construction Industry Standards Council Subcontract form, 1996 edition, includes labor, material, and permit for the installation of the following Scope of Work: 1. Disconnect and remove existing generator, conductors and A.T.S 2. Removal of existing generator concrete pad and. disposal to customer supplied dumpster 3. Rigging, hoisting and Installation. of new custorn.er provided generator 4. Supply, install and level new concrete pre -cast base 8' X 16' for new 100kw generator 5. Supply and install new main disconnect for generator 6, Installation of new customer. provided A._T,S and enunciator panel. 7. Removal and replacement of existing conductors from the new generator to the A.T.S. 8. Replacement of existing conductors and Installation of new 150 amp.breaker from A.T.S to panel EH -1 9. Hauling of old 45kw generator to campus storage yard. However we do not include work not shown on the above- described drawings or in said specifications, design responsibilities or the following: 1. Patching and painting. 2. Pitch pans. 3. Removal of trash from site. 4. Housekeeping pads 5. Responsibility for any underground utilities not clearly marked, and/or any possible hand digging of trenching caused by the presence of any underground utilities located within the digging area. 5965 NW 82` Avenue - MIAMI, FLORIDA 33166 305.592.8777 FAX: 305.592.6978 J 0201412005 12:01 3055926978 Page 2 of 2 Barry University 100 kw Gen Set Upgrade November 22, 2004 Daniel Electrical Contractors, Inc. 6. Fuel, natural gas connection or mechanical work for the generator. 7. Security equipment, fire alarm wiring or installation. 8. Start up and generator, testing by others. 9. Generator manuals to be submitted by the manufacturers representative. 10. No allowances have been included for unforeseen electrical conditions Lurnp Sum: $ 19,316.00 SERJIC.E DEPT PAGE 05/05 This price is based on being afforded site access and reasonably efficient continuity. It is anticipated that this work will be performed during the year of 2004- 2005. The price for this is conditioned upon usage of unaltered AIA contract documents or another contract acceptable to Daniel Electrical Contractors, Inc. This proposal will expire if not accepted within 30 days from date. It is to remain confidential. This proposal will be accepted by you in any of the following methods: a) Utilizing our price, drawings, and/or value engineering ideas for any purpose, including but not limited to sharing or shopping our price or value engineering ideas with any other person., b) requesting us to proceed with any work for the project, c) our beginning to perform work on site at the project after your request, d) use of any of our value engineering work product, e) execution of a written or oral agreement, or f) written acceptance of our proposal, including letter of intention to enter into contract. Upon your review, if you have any questions or need additional information, please do not hesitate to contact me. Sincerely, DANIEL ELECTRICAL CONTRACTORS, INC. Javier R. Flores if this proposal meets with your approval, please sign where indicated below and return same to our office as soon as possible. This will authorize us to proceed with the aforementioned electrical work so as not to delay the project schedule. Progress Payments are due as work is put into place and completed. Signature Title Date 0 NEW EM GEN 100KW- 480V/277 VOLTS Y -4W, 30, 150A t NEW DISCONNECT '200/150A, 30., 600V, 3 POLE 0 EXISTING 150A, 30 AUTOMATIC TRANSFER SWITCH 0 EXISTING LIGHTING PNL 100A, 30, 480/277 VOTS, 24 SPACES, M.L.O., 4W O EXISTING 15KVA XFMR, 480/108 -120 VOLTS, 30, DRY TYPE © EXISTING RECEPTACLE PNL 100A, 30, 208/120 VOTS, 24 SPACES, M.L.O., 4W EXISTING 75KVA XFMR 480V/208- 120VOLT, 30 DRY TYPE. © EXISTING DISCONNECT 200/200A, 30, 240V, 3 -POLE W h X NEW EXISTING 0 EM GEN 40KW- 480V/277 VOLTS Y -4W, 30 © DISCONNECT 100/70A, 30. O 150A, 30 AUTOMATIC TRANSFER SWITCH • PNL 100A, 30, 480/277 VOTS, 24 SPACES, M.L.O., 4W 0 15KVA XFMR, 480/108 -120 VOLTS, 30, DRY TYPE 60 PNL 100A, 30, 208/120 VOTS, 24 SPACES, M.L.O., 4W 70 75KVA XFMR 480V/208- 120VOLT, 30 DRY TYPE. 0 DISCONNECT 200/200A, 30, 240V, 3 -POLE 8X16X6 CONC. PAD 11. 4 #1/0 IN 1 -1/2 "—\ 4 #1/0 IN 2" • 4# 1 IN 1 -1/4 "— CY" 4 #1 IN 2" /E A.T.S. A.T.S. 4 # IN 1 -1/2" 4#1/0 IN 1 -1/2" 4 #1/0 IN 1 -1/2" 4 #1/0 IN 1 -1/2" 4#1/0 IN 1 -1/2 " // /- / ///////0 siRV /— ' / / / / /// / /// 4 #1 IN 1 -1/4" 0 / / // // / / / / / /// OV /-/ // LIGHTING EH -1 0 � •• EH -1 TO SWITCHGEAR AT METER ROOM 150A BREAKER LIGHTING GUTTER GUTTER RECEPT. EL -1 TO SWITCHGEAR AT METER ROOM 70 AMPERES Electrical Engineer. Michael E. Hams 5965 N.W 2 AVE. Miami, • ride 3316 P.E.# 24 Signatur • ,I• RECEPT. EL -1 / /// / /// SCALE: N.T.S. uJ w u 0 a 0 0 0 8 DRAWING REF SHEET* - DATE: 8 -10 -04 REV* 1 1 SHEET#TP -1 rifiThlicrEr - F '0(15 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. 11-2136-000-0050 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street / address: 41 40 A RF. 1 /4 of NF; 1 /4 T,ESS E 35 FT & LESS W4OFT 3n0 NF. 7 AvP .4. A 1 2. Description of improvement 100KW Generator Upgradc 3. Owner(s) name and address: Barry College 11300 NE 2 Ave Interest in property: Name and address of fee simple titleholder. 4. Contractor's name and address Daniel Electrical Contrarto* , S*it- _ Signature of Owner Print Owner's Name Ali- 1( - 1\14.wA.. - STATE OF FLOFUDA, COUNTY OF DADE I ?HEREBY CERTIFY RTIFY that thfr: t^ • ;' nfi tha orb fileci It1ti afar. 7 rs .AD21 w. HRVEY of 'not and County C By 10104 44 C F 2005R0168914 R Bk 23098 Ps 1067; (ins) RECORDED 02/18/2005 11:47 :51 HARVEY RUVIFIe CLERK OF COURT MIAMI -DACE COUNTY? FLORIDA LAST PAGE 5965 NW 87 AvP Mi ami , FT, 33166 5. Surety: (Payment bond required by owner from contractor, if any) Name and Address: Amount of bond $ 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and Address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Uenor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Address: xpiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a ifferent d = s specified) ANIL Prepared byVivi an Perez Notary Public: Print Notary's Name: My commission_expires: (0 , op *x.024 mint 255 ate '76 - /82 St6ven J. Rauser Commission #DD37002?' ; Expires: Nov 0S, 200€ 6FR� :' ` BOIIQed Tf, • "nr.' Atiantic Bonding CU., Inc. 11111111 1111111111111111111111111 [111lIllhIIIi«i APA Sworn to and subscribed before me this /6 day of te4ft.e4 , 20 a.c . Address: BUILDING PERMIT APPLICATION FBC 2001 Qualifier K ri . R . &f...e.lT c Code Enforcement $ Total Fee Now Due $ (Continued on opposite side) Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. Q -• 3 Master Permit No. Permit Type (circle): Building Electrical Plumbing Mechanical Roofing Owner's Name (Fee Simple Titleholder) 134rry 2..otie Phone # 305° $4f — WOO Owner's Address 11340 / v a 2. ii,. City M;Gvn. S bohes State 1=G Zip 33 LCD Tenant/Lessee Name Phone # Job Address (where the work is being done) 1! .300 t'U` 6._ z. 1�ve City Miami Shores Village County Miami -Dade Zip 33 161 Is Building Historically Designated YES NO Contractor's Company Name an, Le/ eo ane,Eo ►hone # 301 .�9-2. ¢3 - 27j Contractor's Address Sg4,6" sr) it) $Z due. City State FL State Certificate or Registration No. p ®b Le9c Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # $ Value of Work For this PermuZ4 bee) Square Footage Of Work: Type of Work: ['Addition DAlteration ❑New g- Repair/Replace 0 Demolition Describe Work: lsl pl r Cp 6-F 4 se i.$ c r esa" 'F 11 tiS !Cud - G ® ®bCr...) 'Ul ****************** *******F F **** * * * * ** **** *** ** * ** * *** ** Submittal Fee $ Permit Fee $ #s,�,�— CCF $ ) 1- "f coicc Notary $ Training/Education Fee $ 6 [ 41b 4�' Technology Fee $ �. Scanning $ Radon $ Zoning Bond $ Structural Plan Review. $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day of ,20_,by who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: * * * * ** **** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * ** L APPLICATION APPROVED BY: Chc 05/13/03 Signature Contractor The foregoing instrument was acknowledged before me this day of ,20by who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: **** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Plans Examiner Engineer Zoning BUILDING PERMIT APPLICATION FBC 2001 Permit Type (circle): Building Miami Shores Village Building Department (0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. Master Permit No. Plumbing Mechanical Roofing Owner's Name (Fee Simple Titleholder) etosri C,4) /le e. Phone # $99 - • OCan Owner's Address 11300 /l7 E: z Aoe City MI' et wi i S beAre5 State a Zip 3 3 /4,/ Tenant/Lessee Name Phone # Job Address (where the work is being done) l l Soo N E City Miami Shores Village County Miami -Dade Is Building Historically Designated YES NO Zip 33/6/ Contractor's Company Name Dat& ieI t (PP4c1a41 C..4DH +re.e-4e Phone# 30f - 5 — 8 77'7 Contractor's Address 5T4.6 /ow Az A City M ( , State (L zip 33/40(0 Qualifier Architect/Engineer's Name (if applicable) Phone # $ Value of Work For this Permit dir If ©e Type of Work: ['Addition ❑Alteration ONew / Repair/Replace 0 Demolition Describe Work: Up 4 r Add ea 4 a )(..t's j 9 ev+e t'a4e,r O q / �0 /64 /cud Submittal Fee $ Permit Fee $ Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ Bond $ Code Enforcement $ Structural Plan Review. $ Total Fee Now Due $ (Continued on opposite side) Square Footage Of Work: CCF $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prim to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first i' . ction hich occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection i ,t be ,'roved and a reinspection e - be charged ip f Signature Owner or Agent The foregoing instrument was acknowledged before me this c . 2 day of Tait • , 20 Or by ate kletc,A/amarea who is personally known to me or who has produced As identifi Nolaty Public - Slab 01141101, PUBLIC• 6 's Chc 10/14/03 NOTAR Sign: Print:ditti APPLICATION APPROVED BY: My Commission Expires: Apr . a l , aool My Commission Expires: n v Signature Contractor The foregoing instrument was acknowledged before me this 26 ' day of aI� c ; y , 20 05 by /Ke, /h Ail; // , who is personally known to me or who has produced as identification and who did take an oath. J . 13 Sign: dadsdityNallonatNotcavAssn. kPrint: ire eJ�ii. ,1 � /€ 4 (Certificate of Competency Holder) State Certificate or Registration No. 64. - op ® 2.4 4 Certificate of Competency No. ALLelit_e_1(2 L z1.4a - 7 . Steven J. Rauser 'on #DD370028 OC: D,,::� N ��� o �� v Ty 0 � 8 ' 2008 o* * * ** **mil ah u �" Atlantic Bonding Co., Inc. Plans Examiner Engineer Zoning