Loading...
46938Date Legal Description Historically Designated: Yes Owner/Lessee / Tenant rr Din fi v e r S7 4 i Owner's Address I l 3' 0 0 N. E 2-Ave, t t u.1 ' S r - l brc S Phone gq -- 1q Contracting Co. V 6 C .J C � t� `�C t v� Address3 4 'ko V c, J v`A b' Qualifier -3 rn C (v Y State #C0( 4- 3 C Municipal # Competency Cali L S Ins Co.1 -I- i e Architect/Engineer Address Bonding Company 1 i Address Mortgagor Address Permit Type (circle one): I DING ELECTRICAL PLUMBING MECHANICA6 FENCE SIGN WORK DESCRIPTION EerOo LA-DI 4h 14( e r q -1_1\ I One S-\--C7r' 0,0ittA a Oh e 5#or1 a r c , —P0.44 o r e a S S1J v. ec_ � � K1 e w 6-1). CI_. i4 oLo/z - /tia ci 6 c/ r � Square Ft. b E Cost (value) ` 'f) , 4 WARNING TO OWNER YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Fjygthermore, I authorize the above -named contractor to do the work 13.04.0- U'�1 Si e of owner and/or Condo President Date FreAkt 1 it all" Aidar No :' Own : , r 111 II • to O ACEVEDO SOTO ,� MY COMMISSION • CC 841281 l'or M1&� FIRES: May 31, 2003 1.800.3.NOTARY Fla Notary Service & Bonding Co. 1 My C FEES: PERMIT APPROVED: Zoning Mechanical • t PERMIT APPLICATION FOR MIAMI SHORES VILLAGE c (c ( loin Job Address it 3 0 ® IQ (2 - i 9 ax Folio / 3 —OQD -oar?) RADON C.C.F. Master Permit # 4&'9 3?5 SS# % Phone l Si — I 2. or e. v\ of Contractor or Owner- Builder Notary as to Contractor or Owner - Builder My Commis •. SANDRA D. HART 41 (COMMISSION it CC623713 l 1T k ' EXPIRES MAR 12.20101 O ;_ £O 114RCUON AMC I ' D IM MO co. g ' 7 NOTARY BO Electrical No Ve2/60 Plumbing Structural Engineer AWN I 'VC �vavuvasima.ivaa.a. ■ • A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION o PERMIT NO. TAX FOLIO NO. ; l i — ' 3 r0d 04.C-1) STATE OF FLORIDA: 01 R 7'37562 2000 MAY 18 11 :22 COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property. and in accordance with Chapter 713, Florida Statutes, the following information is provided in Notice of Commencement. 1. Legal description of property and street address: • K £) P 1 k i ✓1 q 113'00.1\t2e-.:2i:A1C, • Pi Awe ► S h c�1r e s I= I 3 3 l 3S ' 2. Description of improvement: .CA -i �1 q ' 4 i l c ` r.? vl d f). d I- t e 1 3. Owner(s) name and address: r h \-1 ore Av qtr ►ut S h s fI 3313 t1� ��c� WE �� c Interest in property: Name and address of fee simple titleholder: 4. Contractor'' name and address: v b C N bC f C( vl C� ► II-4 q_ Sue()) \t7 C (i t/ 1 t Alt_ Avc. Su + -Jlo) tLtiQk -ti Shoe =:S f 331 5. Surety:(Payment bond required by o Name and address: Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statues, • Name and address: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Comme different date is specified) U K i,vv e c (ry' ' 01 owna c , 1 U (�a•. f15toI �zcccG.t Print Owners Name `t G fir Swom to and subscribed before.me this /,Allay of / , 2 " oP er from contractor, If anypTATE QF FLORIDA, COUNTY OF DADE 1 HEREBY CERTIFY that this is a true 1 y of the ment: (the expiration date is 1 year from the date of recording unless a Notary Public ^ � Print Notary's Name / e v1 I`C 4 e✓ed d S01 My Commission Expires: I A Y 3) l 20r1 Str NMONICA ACEVEDO SOTO s ly MY COMMISSION # CC 841281 "to le EXPIRES: May 31, 2003 1 Ra Notary Service & Bonding Co. 1 Prepared by: Address: WO jWL QP a VU1A , rt 330 123.01-52 7/98 5104 APPENDIX "F" APPENDIX "F "REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 4 As it pertains to this Appendix "F ", it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, to provide the owner with this appendix and to explain to the owner the content of this form. The provisions of Chapter 34 of the South Florida Building Code (SFBC) govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. 1. Aesthetics - Workmanship: The workmanship provisions of Chapter 34 are for the purpose of viding that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are notpart of a zoning code, should be addressed as part of the agreement between the owner and the contractor.- 2. Reuniting Wood Decics: When placing roofing, the existing wood roof deck may have to be ailed in accordance with the current provisions of Chapter 29 of the SFBC. (The roof deck is usually concealed prior to removing the existing roof system) 2 - 3. Common Roofs: Common roofs are those which have no visible delineation between b units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The SFBC provides the option of maintaining this appearance. 5. Ponding Water: The current roof system and/or deck of the building may not drain well and _ cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not loaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with Chapter 23 of the SFBC. 7. Ventllatlon: Most roof structures should have some ability to vent natural airflow through the rior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. ntractor's Signature ' Strip and Removal Glove Bag Bulldozer fi n , ? - Wrecking Ball I _ l L. `.1 . Wet Method s Dry Method Explode Bum Down OTHER: �� ..,11 MIMED .,==zduN 0 7 20 Air '. OTtCE OF ASBESTOS RENOVATION OR DEMOLITION Facility Name Address TYPE OF NOTICE (CMeigaggiggirt Divisi .h O RIGINAL ❑ REVISED p ❑ CANCELLATION TYPE OF PROJECT (CHECK ONE ONLY): ❑ DEMOLITION ❑ RENOVATION [ 4100FING IF DEMOLITION, WAS IT AN ORDERED DEMOLITION? ❑ YES II NO IF RENOVATION: ,r IS IT AN EMERGENCY RENOVATION OPERATION? ❑ YES NO IS IT A PLANNED RENOVATION OPERATION? ❑ YES l 'NO City'; �. 4P ° � " ° : S t a t e r- Zip County Site x I 3• Consultant Inspecting Site h = Building Size 7 (Square Feet) # of Floors Age in Years Prior Use: SchooVCollege/University Residence Small Business Other Present Use SchooVColleke/LJniversi§iD Residence Small Business Other II. Facility Owner : -'- V r4 I a t: ',' f L :. Phone U 4 Address I a , t_ t. h= ! o" 2 6 City 'i , r G;, d _ State 4 Zip III. Contractor's Name f,` /.i €_.T r`;a ` n l,i,-q Phone f 1 °' . Address e : G I'� 9` : ' - ?` i N / ; `' �l City -): , 0::.,, 1 a �' State ,... Zip J Florida Licence No. -' '� t= :: IV. Scheduled Dates: Asbestos Removal (mm/dd/yy) Start ". ^- Finish: E' V. Procedures to be Used (Check All That Apply): tf� • MUST OBTAIN PRIOR DERM APPROVAL BEFORE USIN VI. Procedures for Unexpected RACM:nr, '/ %`a` VII. Asbestos Waste Transporter: Name ;f4 a Y Address Vii. / ii ,r a , (, / —..0 State p. Zip Address r City IX. Amount of RACM or ACM 1 square feet surfacing material linear feet pipe cubic feet of RACM off facility components square feet cementitious material square feet resilient flooring square feet asphalt roofing Environmental Protection Florida Department of Division of Air Resource Management State 1 Zip ❑ COURTESY File # Process # Is the contractor exempt from licensure under section 469.004(7), F.S.? ❑ YES ❑ NO Demo/Renovation (mm/dd/yy) Start: Miami -Dade DERM Air Section 33 S.W. 2nd Avenue, Suite 9-223 Miami, Florida 33130-1540 Finish: Phone ( ) City VIII. Waste Disposal Site: Name Class X. Fee Invoice Will Be Sent to Address in Block Below: ( Print or Type) I certify that the above information is correct and that an individual trained in the provisions of this regulation (40CFR Part 61, Subpart M) will be on -site during the demolition or renovation and evidence that the required training has been accomplished by this person will be available for inspection during normal business hours. . Na of Owner / Operator ('R4N (Signattfre of Owner /Operator (Contact Phone #) DERM USE ONLY Postmark/Date Received ID# �, � fi n , ? - : : A,r _ l L. `.1 . e /1 � :7 �� ..,11 MIMED .,==zduN 0 7 20 Air '. OTtCE OF ASBESTOS RENOVATION OR DEMOLITION Facility Name Address TYPE OF NOTICE (CMeigaggiggirt Divisi .h O RIGINAL ❑ REVISED p ❑ CANCELLATION TYPE OF PROJECT (CHECK ONE ONLY): ❑ DEMOLITION ❑ RENOVATION [ 4100FING IF DEMOLITION, WAS IT AN ORDERED DEMOLITION? ❑ YES II NO IF RENOVATION: ,r IS IT AN EMERGENCY RENOVATION OPERATION? ❑ YES NO IS IT A PLANNED RENOVATION OPERATION? ❑ YES l 'NO City'; �. 4P ° � " ° : S t a t e r- Zip County Site x I 3• Consultant Inspecting Site h = Building Size 7 (Square Feet) # of Floors Age in Years Prior Use: SchooVCollege/University Residence Small Business Other Present Use SchooVColleke/LJniversi§iD Residence Small Business Other II. Facility Owner : -'- V r4 I a t: ',' f L :. Phone U 4 Address I a , t_ t. h= ! o" 2 6 City 'i , r G;, d _ State 4 Zip III. Contractor's Name f,` /.i €_.T r`;a ` n l,i,-q Phone f 1 °' . Address e : G I'� 9` : ' - ?` i N / ; `' �l City -): , 0::.,, 1 a �' State ,... Zip J Florida Licence No. -' '� t= :: IV. Scheduled Dates: Asbestos Removal (mm/dd/yy) Start ". ^- Finish: E' V. Procedures to be Used (Check All That Apply): tf� • MUST OBTAIN PRIOR DERM APPROVAL BEFORE USIN VI. Procedures for Unexpected RACM:nr, '/ %`a` VII. Asbestos Waste Transporter: Name ;f4 a Y Address Vii. / ii ,r a , (, / —..0 State p. Zip Address r City IX. Amount of RACM or ACM 1 square feet surfacing material linear feet pipe cubic feet of RACM off facility components square feet cementitious material square feet resilient flooring square feet asphalt roofing Environmental Protection Florida Department of Division of Air Resource Management State 1 Zip ❑ COURTESY File # Process # Is the contractor exempt from licensure under section 469.004(7), F.S.? ❑ YES ❑ NO Demo/Renovation (mm/dd/yy) Start: Miami -Dade DERM Air Section 33 S.W. 2nd Avenue, Suite 9-223 Miami, Florida 33130-1540 Finish: Phone ( ) City VIII. Waste Disposal Site: Name Class X. Fee Invoice Will Be Sent to Address in Block Below: ( Print or Type) I certify that the above information is correct and that an individual trained in the provisions of this regulation (40CFR Part 61, Subpart M) will be on -site during the demolition or renovation and evidence that the required training has been accomplished by this person will be available for inspection during normal business hours. . Na of Owner / Operator ('R4N (Signattfre of Owner /Operator (Contact Phone #) DERM USE ONLY Postmark/Date Received ID# I certify that the above information is correct and that an individual trained in the provisions of this regulation (40CFR Part 61, Subpart M) will be on -site during the demolition or renovation and evidence that the required training has been accomplished by this person will be available for inspection during normal business hours. Name of Owner / Operator / PRINT (Signature of Owner /Operator (Date) (Contact Phone #) DERM USE ONLY Postmark/Date Received ID# Tr IV Li JUN 0 7 2000 IV. Scheduled Dates: Asbestos Removal ( mm/dd/yy) Start: V. Procedures to be Used (Check All That Apply): IX. Amount of RACM or ACM square feet surfacing material linear feet pipe cubic feet of RACM off facility components square feet cementitious material square feet resilient flooring square feet asphalt roofing Florida Department of Environmental Protection Air Quality Division of Air Resource Management Miami, Florida 33130-1540 NOTICE f ASBESTOS RENOVATION OR DEMOLITION TYPE OF NOTICE (CHECK ONE ONLY): ❑ ORIGINAL ❑ REVISED ❑ CANCELLATION ❑ COURTESY TYPE OF PROJECT (CHECK ONE ONLY):❑ DEMOLITION ❑ RENOVATION ❑ ROOFING IF DEMOLITION, WAS IT AN ORDERED DEMOLITION? ❑ YES ❑ NO IF RENOVATION: File # IS IT AN EMERGENCY RENOVATION OPERATION? ❑ YES ❑ NO IS IT A PLANNED RENOVATION OPERATION? ❑ YES ❑ NO Process # Facility Name Address City State Zip County Site Consultant Inspecting Site Building Size (Square Feet) # of Floors Age in Years Prior Use: School /College/University Residence Small Business Other Present Use School /College/University Residence Small Business Other II. Facility Owner Phone ( ) Address City State Zip III. Contractor's Name Phone O Address City State Zip Florida Licence No. Is the contractor exempt from licensure under section 469.004(7), F.S.? ❑ YES ❑ NO Finish: Demo /Renovation (mm/dd/yy) Start: MIAMI•DADE Miami -Dade DERM Mr Section 33 S.W. 2nd Avenue, Suite 9 -223 Finish: Strip and Removal Wet Method Glove Bag * Dry Method Bulldozer Explode Wrecking Ball Burn Down OTHER: * MUST OBTAIN PRIOR DERM APPROVAL BEFORE USING A DRY METHOD VI. Procedures for Unexpected RACM: VII. Asbestos Waste Transporter: Name Phone (J Address City State Zip VIII. Waste Disposal Site: Name Class Address City State Zip X. Fee Invoice Will Be Sent to Address in Block Below: ( Print or Type) The state asbestos rernoval pu)gram requirements of s. 376.60 F.5, and the renovation or demolition notice requirements of the National Emission Standards for Hazardous Air Pollutants (NESHAP), 40 CFR Part 61, Subpart M, as embodied in Rule 62-257, FA,C., are included on this form. Check to indicate whe hc/ this notice is an original, a revision, a cancellation, or a courtesy notice (be,, not required by law). If the notice is a revision, please specially indicate the entries wbich have been changed or added. Check to indicate whether the project isa demolition nrarenovation. f the deruohton was ordered by the State or a local government agency, in addition to the information required on the form, the owner/operator mug provide the name of the sgency ordering the demoinon, th' tte of the person acting on behalf o( the agency, the agency, the authority for the genc to ord'-r ttie dernohtion, the date of the order, and the date ordered to begm. A copy of the order rnust ako he attached to the notification. lithe renovation is an emergency renovation operation, in addition to the information required on the form, the owner/operator must provide the date and hour the emergency occurred, the description of the sudden, unexpected event, and an explanation of how the event caused unsafe conditions or would cause equipment damage or an unreasonable financial burden. lithe renovation is a planned renovation operation, the notice is effective for a period not to exceed a calendar year o( January 1 through December 31. Complete the fach,ydescription section where the renovation or demolition is scheduled. The address will 6e used hythe Department inspector to oate the project site, Provide the name ofU+e consultant or limn that conducted the asbestos site survey/inspection. For "prior use" and "present" check the appropriate 'box to indicate whether the prior or present use of the facility is that of school, college, or university, residence, as "residential dwe\|ing° is defined in Rule 62-257200, F.A.C..; small business, as defined in s, 288,703(1‘t, ES,; other, If "other" is checked, identify the use, U. Complete the facility owner information. U!. Complete the cumrwtor information. ( However, having n Florida harmer or disclosing the number m not required: mcmnpiv with the notxmuq"i�nm*^ |\( List separately the scheduled start and finish dates (month/day/year) for both the asbestos removal portion of the project and the renovation or don tor porton ef the project. V, Check the methods and procedures to be used, :Note: The NESHAPfo, asbestos, which is adopted and incorporated by refer ence in Rule 62-204.800, F,A.C., requires obtaining Department approval prior to using a dry removal method.) Vi Describe the procedures to be used in the event unexpected RACM is found or previously non friable asbestos material VU. Complete the asbestos waste transporter information. VIII. Complete the waste disposal site information. |X. List the amount of RACM or ACM of each type of ashestos to be rernoved. (Note: A vm| measurement ofRA[«v o facility components is only permissible if the length or area could not be measured previously.) X, Provide the address where the Department is to send the invoice for any fee due. Do not send a fee with the notification. The fee will be calculated by the Department pursuant to Rule 62-257.400, FA.C. Sign the form and mail the original kz the district o,local air program having jurisdicton n the couoty where the project ct is scheduled (D0 \O[ FAX). The correct address can be obtained by contacting the State Asbestos Coordinator at: Department o(Environmental Protection, Division of Air Resources Management, 2600 Blair Stone Road, Tallahassee, FL 32399-2400. r GEOTECHNJCAL ENVIRONMENTAL HYDROGEOLOGY ASBESTOS Miami, May 1 1": Mr. Jim Obenour OBENOUR ROOFING 9301 Park Drive, Suite A101 Miami Shores, FL 33138 Re: Barry University -Kelly Building 11300 NE 2n Avenue Miami Shores, FL Dear Mr. Obenour: The scope of our inspection covered the following areas: A- Roof at the above referenced project. (see attached plan) Sincerely yours, bilisfOot Wis Naamani, P.E. D ATECH ENGINEERING CORP. Florida Reg. No. 39584 Asbestos Consultant No. EA 0045 iii. ''!"N 1111 111 \��1 1110161IN ATECH ENGINEERING CORP. TESTING LABORATORIES DRILLING SERVICES INSPECTION SERVICES ROOFING Pursuant to your request; DYNATECH ENGINEERING CORP., conducted an Asbestos Roof Survey on May 18, 2000 at the above referenced project. The purpose of our inspection was to secure bulk samples for analysis to determine the presence of Asbestos Containing Materials in the proposed renovation area. Access to the interior underside of the roof was not provided and is not part of this survey. Based on our laboratory analysis; it was evident that no asbestos fibers were found in the 'secured bulk samples. This inspection report is the results of a diligent search of the facility for asbestos containing building materials (A.C.B.M.). All analyzed samples were readily available to our surveyor. We do not claim to have identified all of the Asbestos Containing Building Material present in the facility. If in the course of a renovation or demolition activity, suspect materials become exposed, all activities should immediately cease and the suspect material brought to our attention for evaluation and recommendations. It has been a pleasure serving you at this phase of your project and look forward to do so in the near future. 750 West 84 Street, Hialeah, FL 33014 -3618 . Phone (305) 828 -7499 ® Fax (305) 828 -9598 Date Client Project Surveyor No. Sample Type Location 05 -18 -00 OBENOUR ROOFING Property @- Kelly Building- 11300 NE 2° Avenue, Miami Shores, FL : 7ME0209920031R By: C.G. . Bulk Samples Analysis: P.L.M./D.S. F = Friable NF = Non Friable NAD = No Asbestos Detected CHRY = Chrysotile DYNATECH ENGINEERING CORP. ASBESTOS SAMPLING REPORT 750 W. 84th Street, Hialeah, FL 33014 Condition G = Good D = Damaged S = Significantly Damaged Approximate Amount Condition Potential for Damag Analysis 1 2 3 4 5 6 7 8 9 NW side roof N. side roof S. side roof SE side roof NE side roof N. side roof E. side roof N. side roof N. side roof Flat cement roof tiles adhered with mortar to a wood deck Flat cement roof tiles adhered with mortar to a wood deck Flat cement roof tiles adhered with mortar to a wood deck Flat cement roof tiles adhered with mortar to a wood deck Flat cement roof tiles adhered with mortar to a wood deck Flat cement roof tiles adhered with mortar to a wood deck Flat cement roof tiles adhered with mortar to a wood deck Built up roof system over concrete deck Tar & gravel roof system over concrete deck 8700 sq.ft. N/A N/A N/A N/A N/A N/A 700 sq.ft. 250 sq.ft. X X X X X X X X X G/L G/L G/L G/L G/L G/L G/L G/L G/L Analyzed by: Nick DYNATECH ENGINEERING CORP. NIOSH 582 Cert. #7ME090203003DS Potential For Damage L = Low M = Medium H = High NAD NAD NAD NAD NAD NAD NAD NAD NAD 0 o / 0 ■AVAN 1kO1/435E Dynatech Engineering Co Client: O$ENOUR ROOFING Project: N3oo NG 2 as Me dS Mttacti SHIRES, FusgaDtk rp. Scale: N.T.S.v Date: 5.18•0 • 1 • Contractor's Name: (Low Slope Application) UNIIUKM k(UU1H1• PERM 11 AYYL1UA'1ION PROCESS No. DETAIL 1 & 2 ROOF CATEGORY ❑ (Nail -On Tile) Job Address: I 300 G_ _d' ' a (1LS ke 10,i ie nI s I L: (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs\Wood Shingles & Shakes) ❑ (Other) De/Re-roofing ROOF TYPE ❑ New Roof ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft � Sloped Roof Area (ft') 13 I G Total (ft l ) IT 2 .1 Master Permit No. Exposure category (per ASCE 7 -88): C Building Classification category (per ASCE 7 -88 table 1): Ft. A v Ft. A V Deck type: Wood, p1 A�Ik ATTACHMENT Fastener Type: SPACING • Field: • Perimeter: Corner: ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) ?7 0 Page -1 e (Mortar- Adhesive Set Tile) ROOF PLAN V D E T A I L 3 Appendix "E" . UNIFORM ROOFING PERMIT A PPLICA"ION PROCESS No. :J wood r) 1 It 1 ----e— UodKtaymems 4 FM M • D i besegadoec k SLOPED SYSTEM DESCRIPTION rastemar .yr. & spo itgl: ; SLOPS r �4 ado o�a1f1 LE A ( Pmaal: x A (A�y Mme) : • 2 ) • Ma: . o • M o PCA. 9 ( 2: �C X (Ar:ody,�ami. \tuhiplia): �. �) • Mg: /� • Mrs: � s.l X (Aerodynamic Muluplia): ) - M " M ��v PCA: i(f �' (Pmaa3: i• Csp Sint: 'r 0 Dt5'fM L�q wofco.am kIa Page-2 NITA age- ATTA1 *MEWS REQUIRED 1) Fire =tory Listing Page 2) Dade 'omty Product Control Nonce of Ace -Cover Shea a) Sp4 dfic System Description b), SF-dfic System Limitation c) Ge cal Limitations ions d) Alt: pliable Mali Drawings 3) Mani 'pal Pmt Application 4) per. etu Approvals Approved:12 /30/1999 tiU1LDTNG CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 ,MIAh11, FLORIDA 33110 -1563 (303) 375 -2901 FAX (305) 375 -2908 CONTRACTOR LICENSING SECTION (305) 375.2537 FAX (305) 375.2558 CONTRACTOR ENFORCEMENT SECTION (305) 375 -2966 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION Your application for Product Approval of (305) 37S -2902 FAX (305) 372 -6339 Atlantis Shake and Slate Flat Profile Tile under Chapter 8 the Code of Miarni -Dade County governing the use of Alternate Materials and Types of Construction, anil completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall nor be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material im nediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. PRODUCT CONTROL NOTICE OF ACCEPTANCE Monier Lifetile LLC 135NW20St. Boca Raton FL 33431 Acceptance No.:99- 1012.07 (Revises No.: 98- 0604.01) Expires:12 /I6/2002 THIS IS THE COVE SHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING_CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above, MIAMI -DADE COUNTY, FLORIDA METRO•DADE PLAQLER BUILDING Raul Rodriguez Chief Product Control Division rancisco Quintana, Director 1 of 8 Miami -Dade County Building Code Compliance Office 05/31/00 IN IS I. WE" ILE 1. SCOPE This revises a roofing system using Monier Lifetile Atlantis Shake & Slate Concrete Roof Tile, ' e as manufactured Monier Lifetile LLC described in Section o this Edo cceg Lance, designed to comply with the South Florida Building Code, ion for by Miami -Dade County. For the locations where the pressure requirements, obtain by calculations determined in SFC Chapter 23, do not exceed the design pressure values compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. Categ nry: Prepared Roofing Sub Category: Flat Profile Tile 2. PRODUCT DESCRIPTION 1VMano to rem 01 Monier Lifet.le 15 15" Atlantis Shake and w = 10 3/8" State Tile 1 y ' 4 " thick Trim Pieces Err Rainproof 11 Ice and Wa=r Shield I'1t1J l I tr(mmi' r-II V rcuLA ACCEPTANCE No. 99- 10174 A.P'PROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF C PTANCE: S N ARTS CQwI)t ION Dimensto = varies w = varies varying thickness 2.1 Components or products manufactured by others Product gescri tiara Test 1}intension "Petit'1+rntiOns 30 "x75' roll PA 104 36" x75' roll or 60 "x75'roll 36" x 75' roll PA 103 2 ■• Vt/ht.$APO Self - adhering unde Product Descri lion Test ecitications PA 112 Flat, interlocking, high pressure extruded concrete shale and slate roof tile equipped with two nail holes, For direct deck, mortar or adhesive set applications. PA 112 Accessary trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Single ply, nail-on underlayment with 2" self - adhering top edge. TAAh hAh ,AA VV/ AT•AT aanufactarer Protect -O -Wrap Inc. (with current NOA) W.R. Grace Co. 'OA) Frank Zuloaga, RRC Rooting Product Control Examiner n„1♦ -- AA !TT 1TA . 05/31/00 09:05 MEDITERRANEAN ROOF TILE -> 305 7588484 LONIER I. F�Tl1<.E j C od Wood Battens Tile Nails Tile Screws Roof Tile Mortar N/A (' °TileTite'r' ) Roof Tile Mortar ( "Quikrete40 Roof Tile Mortar #1140") Roof' Tile Mortar ("BONSALGt® Roof Tile Mortar Mix ") Root Tile Adhesive ( "Polyproe AH 160 ") T CE OF ACCE Pjmens'tons Vertical Min. 1 "x 4" Hontal Min. 1 "x 4" (or use with vertical battens or Min. 1 "x 2" for use alone Min. 10d.x3" #8:4,2 Vi" long 0.335" head dia. 0.131" shank dia. 0.175" screw thread dia. . N/A N PA 114 Appendix E PA 114 Appendix E PA 123 PA 123 PA 123 See PCA Corrosion resistant screw or smooth shank nails Corrosion resistant. coated, square drive, galvanized, coarse thread wood screws Prepared mortar mix designed far mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mi:c designed for mortar set roof tile applications. generic generic ACCEPTANCE No.:_914L/1.2.12. APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NC>E: ST -. D AR1) Cf3[vD1TfONS Test Product S eeifi .ions pescri tan Mrti tufacture.r Wood Preservers Salt pressure treated generic Institute LP — 2 or decay resistant lumber battens Bermuda Roof C Inc, with current PCA. Quikrete Construction Products with Current PCA W. R. Bonsai Co. with current PCA Two component Polyfoam Products, polyurethane Inc. adhesive designed for a dhesive set roof tile applications. Frank Zutoa,a, RAC Roofing Product Control Examiner 05/31/ 09:06 MEDITERRANEAN ROOF TILE 3 365 7556434 MOlER LIF,ETILE LLC Product Roof Tile Adhesive TileBond Hurricane Clip & Fasteners 3. LIMITATIONS NOTICE OF _CCE w e n sions Factory premixed canisters Clips Min.'/:' width Min. 0,060" thick Clip Fasteners Min. Sd x l %" 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with PA 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayrnent applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3,6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with chapter 29 of the SPBC. 3.7 May be installed on slopes 7 :12 and greater with a minimum of two screws. 4. INSTALLATION 4.1 Monier Lifetile Atlantis Shake & Slate Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Tile Profile Monier Lif +tile Atlantis Shake & Slate Tile Dl _UAL CE• ST Test S,pecifrgtionst See PCA PA 114 Appendix E 4 ACCEPTANCE No.: 99- 1012.07 APPROVED EXPIRES A DARD CONDITIONS Product Descj'iption Single component polyurethane foam roof tile adhesive Corrosion resistant clips with corrosion resistant nails. M:inufu tur 110. 1 J :December 30, 1999 :December 16, 2002 Flexible Products (with current NOA) Generic Table 1: Aerodynamic Multipliers - h (ft') X. (ft ) Direct Deck Application .x"-40 -� ran uIonsa, RR Roofing Product Control Exam 05/31/00 09:06 MEDITERRANEAN ROOF TILE 4 305 753334334 lMIONIER L1 ETILE Tab Tile Profile Monier Lifetile Atlantis Shake & Slate Tile Tile Profile Monier Lifetile Atlantis Shah :e & Slate Tile NOTICE 0 'Cable 3: to 2: Restoring M 3 ":12" Direct Deck 6,0 TANCE: STANDJ. t D DITI oments due to Gravity - M (ft -lbf) 4 ":12" 6 ":12 " Direct Deck 5.9 Attachment Resistance Expressed as a Moment - M, (ft -Ibf) for Nail-On Systems Fastener Type Direct Deck Direct Deck Battens (min 15/32" (min. 19/32" plywood) plywood) 2 -10d Ring Shank Nails 1 -10d Smooth or Screw Shank-Nail 2.10d Smooth or Screw Shank Nails 1 #8 Screw 2 #8 Screw 1 -10d Smooth Or Screw Shank Nail (Field Clip) 1 -10d Smooth or Screw Shank Nail (Eave Clip) 2 -10d Smooth or Screw Shank Nails (Field Clip) 12 Od Smooth or Screw Shank Nails (Eave Clip) 30.9 -F 7.3 14.0 30.8 51,7 24. 31,9 Monier tactile Atlantis Snake & Slate Tile Adhesive 2 See manufactures component approval for instattation req uirement , Flexitale Products Company TileSend Average weight per patty 13.9 grams. Pol earn Product A vers a wei ht pet pa B ra ms. 5 ACCEPTANCE No.: 99- 1012.97 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 6 ":12 " Direct Deck Direct Deck DirectDeck 5.6 j 5.6 - 5.5 38.1 9.8 18.8 51.7 19,0 19.0 35.5 ---r---- 35.5 7 " :12" or greater 24,3 31.9 65.5 2 -10d Ring Shank Nails' 50.3 Installation with a 4" tile headlap and fasterners are located a min. of 2 from head of tile. Table 4: Attachment Resistance Expressed as a Moment M, (ft -Ibf) for Two Pa Ad Set Systems Tile Profile Tile Application Minimum Attachment Resistance 31,3' raiik uloaga. RRC Roofing Product Control Examiner HO. 02R D05 17.2 49 7.4 18.2 24.4 24.2 22.1 34.8 32.2 48,3 05/31/00 09:07 MED I TERRRNEHN KUUh 1 1 t r att.+o4 MONIER. LIFETILLLIS NOTICE OF ACCEPTANCE: ST NDARD C Isi DITIONS Table 4A: Attachment Resistance x Set S as a Moment - M, (ft - lbf) a for Single Patty mum Attachment -- ..caton Minimum 115.9 40.4 Tile Profile Monier Lifetila Atlantis Shake & Slate `file Large • cld plac ement of 4$ rams of PolyPro r" Medium eddy placement of 24 grams of PolyProT ". I3: Attachment Resistance Expressed as a M oment - M, (ft-Ibf) for Mortar or Adhesive Set Syst Attachment Tile Tile A pplication Resistance Profile 39.0 Monier L.ifet,le Atlantis & Slate ` file °ra Sett 5. LABELING All tiles shall bear the imprint or identifiable marling of the manufacturer's name or logo. or following statement: "Miami -Dade County Product Control Approved". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following! ti.1.1 This Notice of Acceptance. 6.1.2 Any other documents rewired by the Building Official or the South Florida luilding Code (SFBC) in order to properly evaluate the installation of this system. 6 ACCEPTANCE No.: 99- 1012.07 APPROVED :December 30, 1999 EXPIRES :Decernber 16, 2002 11143 Frank Zuloaga, R.RC Roofing Product Control Examiner tJJ /.J J. tj'e MEDITERRANEAN ROOF TILE -3 305 7588484 MONIER LIFETILE LLC ACCEPTANCE No.: 99-1.012.07 NOTICE OF ACCEPTANCE: STANDA COND_ir PROFILE DRAWINGS LOCK ww.,. ,.•w '•� ,:'v..,. w� • •w` ' -.. •~ `..r ti w •w .- . •% • ..�. ..ti. 4VEP4.AY •, OVERLAY 7 APPPOVED :December 30, 1999 EXPIRES :December 16, 2002 1 MONIER LIF£TIL,E ATLANTIS SHAKE & SLATE CONCRETE ROOF TILE Frank Zulonga, RRC Ro. fing Product Control Examiner NO. A21 P07 05/31/00 09:08 MEDITERRANEAN ROOF TILE .4 305 7588484 MONIER, (METTLE LLC ACCEPTANCE No. 99�141122 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NQ' ICE OF ACCEPT C : S'I'AND R.D ONDITLQI Renewal of this Acceptance (approval) shell be considered after a renewal application has been filed and the original submitted documents, including test - supporting data, engineering documents, are no alder than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approval ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a. There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes. b. The product is no longer the same product (identical) as the one originally approved. c. IF the Acceptance holder has not complied with all the requirements of this. acceptance. including the correct installation of the product. d. The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall autom;.ticaliy be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any ol' the following shall also be grounds lot removal of this Acceptance: a. Unsatisfactory performance of this product or process. b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failum to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1 through 7 and this last page 8. END OF THIS ACCEPTAN 8 Frank Zuloaga, RRC Roofing Product Control Examiner Nu. 82E_ Poi8 • PRODUCT CONTROL NOTICE OF ACCEPTANCE GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 Your application for Product Approval of: GAF Ruberold® Modlfed Bitumen Roof Systems for Concrete decks under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Factory Mutual Research Corporation, Underwriters Laboratories, Inc., and Exterior Research & Design, LLC Trinity Engineering has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -61 and the standard conditions on page 62. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the manner, the Building Code Compliance Office may revoke, modify, or suspend the use of-such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florica Building Code. The expense of such testing will be incurred by the manufacturer. � ' -' _ a Acceptance No.: 97- 0804.16 Renews No.: 95- 0330.06 y'� 1 T/ Expires: ' 11/06/00 Raul Rodriguez Product Control Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. n • (2 4 Charles Danger, P.E. Director Building Code Compliance Dept. Approved: 11/06/97 Metropolitan Dade County 1 Applicant: GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 Category: Sub - Category: Type: Sub -Type: PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Membrane Roofmg System Built -up Roofing Modified Bitumen APP and SBS Product Control No: 97 0804.16 Product Control No.: 97- 0804.16 Approval Date: November 6, 1997 Expiration Date: November 6, 2000 System Description GAF Materials Corporation has been manufacturing commercial roofing products for more than 100 years. GAF produces a wide range of roof products for built -up roofing systems. The modified bitumen products include both APP and SBS products in smooth, granule and fire rated versions. In addition, GAF offers two ply modified systems to meet the specification requirements for multilayer SBS modified specifications. GAF products are distributed through a wide network of roofing wholesale distributors throughout the South Florida area. GAF provides warranted systems over various insulated and non - insulated substrates, copies of which can be obtained from GAF and can be found in the Ruberoid Modified Bitumen Application and Specification manual published annually. GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and Underwriters Laboratories. GAF modified bitumen membranes have been tested in compliance with ASTM D 5147 test requirements. Contact: William J. Woodring Director of Technical Services (973) 628- 4134 Page 2 of 62 Frank Zuloaga, Roofing Product Control Examiner Membrane Type: SBS Deck Type 3: Concrete Decks, Non - insulated, New Construction Deck Description: 2500 psi structural concrete or concrete plank System Type D(4): Base sheet adhered with approved asphalt. All General Limitations shall apply. Base Sheet: Ply Sheet: Membrane: Surfacing: Maximum Design Pressure: Maximum Fire ' Classification Maximum Slope: Specification No.: Product Control No: 97 0804.16 Install one ply of GAFGLAS® #75, GAFGLAS #80 UlltimaTM Base Sheet, GAFGLAS® PLY 4 ®, GAFGLAS'l PLY 6 ®, GAFGLAS FlexPly TM 6, RUBEROIDTM Modified Base Sheetor RUBEROID® 20 directly to the primed deck. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20- 401bs.sq.. (Optional) one or more plies of GAFGLAS® PLY 4® or GAFGLAS® PLY 6® or GAFGLAS FlexPlyTM 6 ply sheets adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. One or more plies ply of RUBEROID MOP Smooth, Ruberoid® Mop Granule, RUBEROID ULTRACLADTM, Ruberoid® Mop 170 FR, Ruberoid® Mop Plus Granule, Ruberoid® Mop FR, RUBEROID ULTRACLADTM , Ruberoid® 30 or Ruberoid® 30 FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.. (Optional, required over RUBEROID MOP Smooth) Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 Ibisq. 2. GAFGLAS Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. -457.5 psf Class 'A'; see General Limitation #2. 1:12; see General Limitation #3. Page 45 of 62 /,SP" rank Zuloaga, Roofing Product Control Examiner t Product GAF Asphalt Concrete Primer GAF Mineral Shield® Granules GAF WeatherCoat® 5 gallons Emulsion GAF Premium Fibered Aluminum Roof Coating GAF Jetblak All Weather Plastic Cement GAF Aluminum Emulsion GAF Aluminum Roof Paint GAF Built -Up Roofing Asphalt GAFGLAS® #75 GAFGLAS #80 UltimaT' Base Sheet GAFGLAS Ply 6® GAFGLAS FlexPlyTM6 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Dimensions Specification 5, 55 gallons ASTM D 41 60 lb. bags ASTM D 1863 1, 5 gallons ASTM D 2824 1, 5 gallons 5 gallons 5 gallons 100 Ib. cartons, bulk ASTM 1227 ASTM D 3019 Refined asphalt blended with a mineral ASTM D 3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM D2824, Type I ASTM D312, Tpyes I, II, III and IV 3 sq. roll ASTM D 4601 751b. roll 2 Sq. Roll ASTM D4601 70 lbsiroll 5 sq. roll ASTM D 2178 45 Ib. roll 5 sq. roll ASTM D 2178 45 lb. roll Page 4 of 62 Product Control No: 97- 0804.16 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. Surface coating for smooth surfaced roofs. Fibered aluminum coating. Mineral colloidial bituminous emulsion with reflective aluminum flakes Non- fibered. aluminum pigmented, asphalt roof coating Interply mopping and surfacing asphalt Asphalt impregnated and coated glass mat base sheet. Asphalt impregnated and coated, fiberglass base sheet Type VI asphalt impregnated glass felt with asphalt coating. Type VI t g ass with asphalt eat,ng. Frank Zuloaga, Roofing Product Control Examiner Product Ruberoid® Torch Smooth Ruberoid® Torch Plus (Granule) Ruberoid® Torch Granule Ruberoid® Torch FR Ruberoid® Mop Plus (Granule) Ruberoid® Mop FR Ruberoid® 20 Ruberoid® 30 Ruberoid® 30 FR Ruberoid® Mop 170 FR Vent Stacks (metal and plastic) Test Dimensions Specification 1 sq. roll ASTM D 5147 87 lbs. % sq. roll ASTM D5147 93 Ib. roll 1 sq. roll ASTM D 5147 102 Ib. roll 3/4 sq. roll ASTM D 5147 90 lbs. 1 sq. roll 102 lbs. 1 sq. roll 105 lbs. 1.5 sq. roll ASTM D 5147 95 lbs. 1 sq. roll ASTM D 5147 92 lbs. 1 sq. roll 92 lbs. 1 sq. roll 103 lbs. Page 8 of 62 Product Control No: 97 0804.16 Product Description Heavy duty, polyester reinforced, asphalt modified bitumen membrane. Heavy duty, polyester reinforced, asphalt modified bitumen membrane. Asphalt impregnated, coated felt, surfaced with mineral granules. Non -woven polyester mat coated with fire retardant polymer modified asphalt surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with fire- retardant, polymer modified asphalt surfaced with mineral granules. SBS modified asphalt base sheet reinforce with a glass fiber mat. Non woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non woven fiberglass mat coated with fire retardant, polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with fire retardant polymer modified asphalt surfaced with mineral granules. PA 100(A) One way valve vent used to relieve ASTM D 1929 built -up pressure within the roof system. ASTM D 635 " GAF Vent Stacks are available in metal or plastic. ran Zuloaga, Roofing Product Control Examiner GENERAL LINIITATIONS 1 All asphalt shall comply with ASTM D 312 type III or type IV requirements, and approved by applicant. 2 Fire ratings are determined by a combination of slope, deck type and assembly. Refer to current Underwriters Roofing Materials Directory or other fire testing data listed in the testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 of the South Florida Building Code. 3 Maximum slope range shall vary for each system; consult current Underwriters Laboratories Roofing Materials Directory and manufacturer's specifications for compliance with design criteria for each project. 4 An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet may be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs.sq. Note:, Spot attached systems shall be limited to a maximum design pressure of -45 psf except where GAFGLASI STRATAVENT® Perforated is used, the maximum design pressure is limited to — 90psf.. 5 All work shall be performed by a contractor licensed to do roofing work in Metro - Dade County. Contractor shall be familiar with the details and specifications published by the manufacturer, and the requirements of the SFBC. 6 The submission of system specifications and details shall accompany the Section II Building Code Permit. This information is available in the publications listed in the 'System Description' of this Product Control Approval. The submission of these documents, as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. 7 Perimeter and corner areas shall comply with the enhanced uplift pressure of these areas, as calculated in compliance with Chapter 23 of the,South Florida Building Code. Fastener densities shall be increase for both insulation and base sheet as needed calculated in compliance with Metro -Dade County Roofing Application Standard PA 117. (When this limitation is specifically referred within this NOA, General Limitation #20 will not be applicable.) Page 59 of 62 Product Control No: 97- 0804.16 Pratruloaga, Roofing Product Control Examiner 8 All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Metro -Dade County Roofing Application Standard PA 111 and the wind load requirements of Chapter 23 of the South Florida Building Code. 9 Flashings shall be installed according to the manufacturers standard details, and may be applied in cold application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be submitted with the Section II Permit Application. All details shall comply with the provision of the South Florida Building Code. 10 Fastener spacing for base sheet attachment is based on a Minimum Characteristic Force (F) value as tested in compliance with Metro-Dade County Protocol PA 105. If the fastener values as tested are below those listed in the System Limitations, a professional engineer may submit a revised fastener spacing utilizing the withdrawal resistance value taken from a Metro- Dade County Protocol PA 105 test report and calculations that comply with the wind load requirements of Chapter 23 of the South Florida Building Code and Roofing Application Standard PA 117. 11 Fastener spacing for insulation attachment is based On a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with PA 105. If the fastener value, as field tested, are below 275 lbf. insulation attachment shall not be acceptable. 12 Asphalt moppings shall be with applied with approved asphalt and shall be in compliance with equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and temperature ranges shall be in compliance with Subsection 3403.4(a)(3) of the South Florida Building Code. 13 Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or adhesive, which shall comply with provision of Roofing Application Standard PA 117. 14 All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 15 In re- covery/re- roofing applications, prior to the application, all existing roof surfaces used as a bonding substrate shall be tested in compliance with Metro-Dade County Protocol PA 124 for uplift resistance. Test pressures shall be calculated in complianc w it iJ e wind Load requirements of Chapter 23 of the South Florida Building Code to the-des; : ugii s'sureiRf the roof. Page 60 of 62 Product Control No: 97- 0804.16 uloaga, Roofing Product Control Examiner • Product Control No: 97- 0804.16 16 In re- roofing applications, moisture content in an existing roof must be in compliance with Section 3401.10(m), (n) of the South Florida Building Code. 17 Roll good materials shall be stored on end and on a clean, flat and dry surface. 18 If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or approved adhesives may be used prior to the application of the insulation layer. 19 Consult current Underwriters Laboratories Directory for the appropriate coating for each roofing assembly to obtain the required fire rating. The assembly shall be installed in strict compliance with sections 3401.5 and 3401.6 of the South Florida Building Code for maximum fire classification. 20 The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) Page 61 of 62 Zuloaga, Roofing Product Control Examiner a Product Control No: 97- 0804.16 GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 1 ACCEPTANCE NO.: 97- 0804.16 APPROVED: November 6, 1997 EXPIRES: November 6, 2000 NOTICE OF ACCEPTANCE STANDARD CONDITIONS Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Metro-Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as lie one originally approved; c) lithe Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Metro-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8 Failure to comply with any section of this Acceptance'shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through 62 END OF THIS ACCEPTANCE Page 62 of 62 N • uloaga, Roofing Product Control Examiner • ROOF COVERING MATERIALS (TEVT) 1999 Roofing Mate ROOFING SYSTEMS (TGFU)— Continued ;`Deck: NC Incline: 1/4 Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or " Polyfoam '' 1 in. min. Base Coat: One or two applications "Gacoflex LIB- 7050 ", applied at 1 gal/sq/application or three applications, applied 1 -1/4 gat/sq/application I 16 -32 dry mils). urfacing: "Gacoflex UA-65" Series (various colors), applied 1 gal /sq (12 dry mils). Deck: NC Incline: 1/2 Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or " Polyfoam 303 ", 1 in. min. Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 gal/sq/apptication or three applications, applied 1 -1/4 gal/sq/application $ (16 -32 dry mils). urfacing: "Gacoflex UA -60" Series (various colors), applied 1 gal/sq (15 dry mils). Deck: NC Incline: 2 Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or " Polyfoam 303 ", 1 in. min. Base Coat: "GacoSil 5- 1000 ", applied at 1 gal /sq (10 dry mils). Surfacing: "Gacoflex S- 1000 ", applied at 1 gal /sq (10 dry mils). Deck: NC Incline: 1 Foam: "Polyfoam 251" or "Polyfoam 303 ", any thickness. Surfacing: "Gacoflex Ure- Shield 7007 ", 40 dry mils. I, Deck: NC Incline: 2 ;i Foam: " Polyfoam 275 ", any thickness. Base Coat: "Gacoflex A- 6211 ", 1 -1/2 gal /sq (14 dry mils). Surfacing: "Gacoflex A- 6200" series (various colors), 1 -1/2 gal /sq (14 dry mils). Deck: NC Incline: 2 Foam: Polyfoam 251, "Polyfoam 275" or "Polyfoam 303 ", any thickness. Base Coat: One or two applications "Gacoflex UB- 7051", applied at 1 gal /sq. /application (16 -32 dry mils). Surfacing: One application of "Gacoflex A -55 Series" (various colors), applied at 1 -1/2 gal /sq. (15 dry mils). 3S. Deck: NC Incline: 1/4 i! Foam: " Polyfoam 251 ", " Polyfoam 275" or " Polyfoam 303 ", any thickness. Base Coat: "Gacoflex UB -64," applied at 1 -1/2 gat/sq. (18 dry mils). Trowel Coat: 30/60 mesh crushed walnut shells mixed at a rate of 5 lb /gat with "Gacoflex UB -64," applied at 1 -1/2 gal /sq or "Gacoflex UB -64 ", applied at 1 -1/2 gal /sq (18 dry mils) followed by the broadcast application of 30/60 mesh crushed walnut shells applied at 7 -8 lb /sq. Surfacing: "Gacoflex U -66 ", applied at 1/2 gal /sq. (6 dry mils). GAF MATERIALS CORP R1306 '1361 ALPS RD, WAYNE NJ 07470 'RUBEROID 20" or "RUBEROID Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. "1/2 in. thick (min) gypsum board or 1/4 in. thick (min) Georgia - Pacific :'Dens- Decke" overlayment board may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is `acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board and overlayment board are offset 6 in. with the joints in the deck. If polystyrene is part of the roof system, it must be placed below the dverlayment board. Also, multiple plies of "GAFGLAS Ply 4" or "Ply 6" may be adhered to "Dens- Deck" in hot asphalt. "GAFGLAS Stratavent Nailable Base Sheet" may be mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof ems. -,GAFGLAS Perlite Insulation may be utilized as a cover board over "EVERGUARD" ;insulation in any of the following systems. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet" or " GAFGLAS #80 Premimum Base Sheet ") is a suitable alternate for Type G1 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or " GAFGLAS Ply 6 ") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with a Type G2 asphalt glass mat base sheet "GAFGLAS Stratavent (Vent -Ply) perforated" or "GAFGLAS Stratavent (Vent-Ply) for nailable decks ". Perforated to be mopped and nailable to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet", " GAFGLAS #80 Premium Base Sheet" or "GAFGLAS Stratavent (Vent -Ply) for nailable decks ") may be substituted for 61 asphalt glass fiber ply sheet _r6AFGLAS Ply 4" or " GAFGLAS Ply 6 ") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened. LOOK FOR THE UL MARK ON PRODUCT systems Directory ROOF COVERING MATERIALS (TEVT) 141 ROOFING SYSTEMS (TGFU) — Continued "GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes "GAFTEMP PERMALITEee" or any other UL Classified perlite insulation. Crushed stone or stag are suitable alternates for gravel in any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C -15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1/2 in. min gypsum board is an acceptable alternate for insulation over C -15/32 decks. The use of polystyrene insulation board between min 3/4 in. perlite board and deck with rosin paper (perlite /rosin paper /polystyrene /perlite) is a suitable alternate for isocyanurate board in the following Class A, B or C systems. "GAFTEMP Isotherm RA ", " GAFTEMP Tapered Isotherm RA" and "GAFTEMP Composite A" may be substituted for any isocyanurate insulation in any of the following Classifications. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". GAFGLAS #80 Premium Base Sheet may be used in any of the following systems. Class A, B and C. Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. Class A 1. Deck: C -15/32 Incline: 3 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or4nore layers Type 61 "GAFGLAS Ply 4" or " GAFGLAS Ply 6 ", hot mopped. Surfacing: Gravel. 2. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber / isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers Type 61 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet". 3. Deck: NC Incline: 2 ? Insulation (Optional): One or more layers perlite wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiberfisocyanurate composite, phenolic, 2 in. max. Ply Sheet Two or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet". 4. Deck: NC Incline: 1/2 Insulation: One or two layers "Isotherm R ", 4 in. max, hot mopped. Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. eck: C -15/32 Incline: 1 �' • Slip Sheet (Optional): Red rosin paper, nailed to deck. Base. Sheet: One layer of Type G2 "t;AFGLAS #75 Base Sheet" (may be nailed). • Ply Sheet One or more layers of Type 61 "GAFGLAS Pty 4" or GAFGLAS Ply 6". Cap Sheet One layer of Type G -3 " GAFGLAS Mineral Surfaced Cap Sheet ". 6 ) Deck: NC Incline: 3 ' Base Sheet One layer of Type G2 "GAFGLAS #75 Base Sheet". Ply Sheet One or more layers of Type G1 " GAFGLAS Ply 4" or GAFGLAS Ply 6 ". Cap Sheet One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet; 7. Deck: C -15/32 Incline: 2 Insulation: One or more layers perlite, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane composite, phenolic, 1.0 in. min (offset from plywood joints 6 in.). Base Sheet One or more layers of Type 61, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Cap Sheet "GAFGLAS Mineral. Surfaced Cap Sheet ", hot mopped. 8. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite / isocyanurate composite, perlite/ urethane composite, wood flber / isocyanurate composite, phenolic, any thickness. ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU) Continued 4 in. (min) Georgia- Pacific "Dens Deck® Overlayment" are used directly the deck with all joints staggered 6 in. (min) from plywood joints. A.vapor barrior may be optionally installed under all systems utilizing GUARD" insulation. " EVERGUARD" insulation is an acceptable alternate any polyisocyanurate insulation of the following systems. GAFGLAS may be used as an option over EVERGUARD insulation. GAFGLAS nt Perforated Base Sheet may be utilized as an additional ply in of the following systems. Class A - Ballasted Deck: NC Incline: 2 Insulation: One or two layers "Isotherm R ", any thickness, loose laid or mechanically fastened. Membrane: Any'UL Classified membrane used in a ballasted system. Surfacing: River bottom stone, 3/4 to 1 -1/2 in. diam, 1000 lbs /sq. Deck: C -15/32 Incline: 1/4 (NC -2) 6., Insulation: Perlite, glass fiber or wood fiber, 3/4 to 1 -1/2 in. Membrane: "Ruberoid® Torch 1" (modified bitumen). Surfacing: Gravel at 400 lbs /sq, loose laid or concrete blocks, at 10 .. lbs /sq and spaced not more than 1/8 in. Deck: NC Incline: 3 Insulation (Optional): Perlite, glass fiber or wood fiber, 3/4 to 1 -1/2 in. Base Sheet (Optional): Type 15 asphalt organic felt or Type G2. Membrane: "Ruberoid® Torch 1" (modified bitumen). Surfacing: Gravel. Deck: C -15/32 Incline: 1/4 Insulation (Optional): Perlite, glass fiber or wood fiber, any thickness. Membrane: "Ruberoid® Torch 1" (modified bitumen). Slip Sheet: 0.004 in. polyethylene (not UL Classified). Surfacing: 3/4 in. thick concrete with one layer of No. 10 Summerville Quarry tile (or equivalent) grouted in place. 5. Deck: NC Incline: 2 Insulation (Optional): Perlite, glass fiber or wood fiber, any thickness. Membrane: "Ruberroid® Torch 1" (modified bitumen). Surfacing: 3/4 to 1 -1/2 in. diam river bottom stone at 1000 lb /sq or concrete pavers weighing not less than 10 lb /sq ft and spaced not more than 1/8 in. 6. Deck: NC Incline: 3 Insulation: a)Polystyrene, 2 in. max, b)Isocyanurate, any thickness, laid loosely. Membrane: "EverGuard SR" or "EverGuard FB ", 40 -100 mil (TPA), laid loosely. Surfacing: River bottom stone (3/4 - 1 -1/2 in. diam) at 1000 lb /sq or concrete roof pavers. Class A - Fully Adhered 1. Deck: NC Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Base Sheet Optional): One or more layers Type G1, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Gravel, 400 lbs /sq, loose laid or applied in a flood coat of hot roofing asphalt. 2. Deck: NC Incline: 1/2 Base Sheet (Optional): One or more layers Type G1, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Coating: Karnak No. 97, 1 -1/2 - 3 gal /sq. 3. Deck: NC Incline: 1/4 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, any thickness. Base Sheet (Optional): One or more layers Type G1, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule). Coating: Karnak No. 97, 1 -1/2 - 3 gal /sq. 4. Deck: C -15/32 Incline: 1/2 Insulation: One or more layers perlite, glass fiber, isocyanurate, urethane, perlite / isocyanurate composite, perlite /urethane composite, phenolic, 1 -1/2 in. min thickness (offset from plywood joints 6 in.). Base Sheet: One or more layers of Type G2 or G3. Ply Sheet (Optional): One or more layers of Type G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Karnak No. 97, 1 -1/2 - 3 gal /sq. 5. Deck: NC Incline: 1/2 1999 Roofing Materials and Systems Directory 6. 7. 8. 9. 10. 11. 12. 13. LOOK FOR THE UL MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) 143 ROOFING SYSTEMS (TGFU) Continued Base Sheet (Optional): One or more layers of Type G1, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule). Surfacing Optional): Karnak "No. 97" or "169" at 1 -3 gal /sq or Grundy Ind. "20 F Emulsion" at 3 gal /sq. Deck: C -15/32 Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane composite, phenolic, 1 -1/2 in. min. Base Sheet (Optional): One or more layers of Type G1, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule). "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Gravel. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite] urethane composite, wood fiber /isocyanurate composite, phenolic. Base Sheet: Two or more layers of Type G2 or G3. Ply Sheet (Optional): One or more layers of Type G1. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule). "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Karnak No. 97, 1 -1/2 - 3 gat/sq or gravel. ,Deck: NC Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane composite, phenolic, 1 -1/2. in. min. Base Sheet (Optional): One or more layers of Type G1, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: "AL MB Aluminum Roof Coating" at 1-2 gal /sq. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, phenolic, 1 -1/2 in. min. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4 ", hot mopped in place. Membrane: "Ruberoid Mop FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1 - 1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, phenolic, 1 -1/2 in. min. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet" hot mopped or mechanically fastened in place. Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4 ", or "GAFGLAS Ply 6" hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1 - 1/2 gal/so or GAF Weather Coat Emulsion at 3 gal /sq. Deck C -15/32 Incline: 1/2 Insulation: Isocyanurate, 2 in. min., wood fiber, perlite or glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ". hot mopped or mechanically fastened in place. Ply Sheet (Optional): One or more layers of Type G1 "GAFGLAS Ply 4" or "Ply 6" hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal /sq or GAF. Weather Coat Emulsion at 3 gal/sq. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Isocyanurate, perlite or glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. Base Sheet One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4" or "Ply 6 ". hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1 - 1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. Deck: NC Incline: 1/2 Insulation (Optional): Isocyanurate, wood fiber board, perlite, glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. 1 • 144 ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU) — Continued Base Sheet One or more Layers of Type G2 " GAFGLAS #75 Base Sheet ", hot mopped in place. Ply Sheet (Optional: One or more layers of Type 61 "GAFGLAS Ply 4" or "Ply 6" hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optional): "GAF Fibered Aluminum Coating" at 1 -1/2 gal/sq or GAF Weather Coat Emulsion at 3 gal/sq. 14. Deck: NC Incline: 1/2 Insulation (Optional): Isocyanurate, wood fiber board, perlite, glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. Base Sheet One or more layers of " GAFGLAS #75 Base Sheet ", hot mopped in place. Ply Sheet (Optional): One or more Layers of "GAF GLAS Ply 4" or "Ply 6" hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optional): GAF Weather Coat Emulsion applied aj: 3 gal /sq or \GAF Fibered Aluminum Coating at 1 -1/2 gat /sq. ck: C -15/32 Incline: 1/2 nsulation (Optional: Perlite, fiber glass, isocyanurate, urethane, perlite/ isocyanurate composite or phenolic,. e ,„, �, Base Sheet One or more layers Type Gtr 537bafe sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers Type 61, hot mapped in place. Membrane: "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule): 16. Deck: C -15/32 Incline: 1/2 Insulation (Optional?: Perlite, fiber glass, isocyanurate, urethane, perlite/ isocyanurate composite or phenolic, offset 6 in. from joints. Base Sheet One or more layers of Type G -2 or G -3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers of Type G -1, hot mopped in place. Membrane: One layer of "Ruberoid Torch" or "Ruberoid Mop" (smooth). Membrane: One layer of "Ruberoid Torch 170FR" or "Ruberoid Mop FR" (granule) 17. Deck: NC Incline: 1 Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate, urethane, perlite /isocyanurate composite or phenolic. Base Sheet One or more layers Type G2 or G3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers Type 61, hot mopped in place. Membrane: One layer of "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule). 18. Deck: NC Incline: 1/2 Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate, urethane, perlite /isocyanurate composite or phenolic. Base Sheet (Optional): One or more layers of Type G -2 or G -3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers of Type G -1, hot mopped in place. Membrane: One layer of "Ruberoid Torch" (smooth), "Ruberoid Mop" (smooth). Membrane: One layer of "Ruberoid Torch 170FR ", "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule). 19. Deck: NC Incline: 1/2 Insulation (Optional): One or more layers of perlite, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite or phenolic, any thickness. Base Sheet One or more plies 61 or G2, hot mopped or adhered with Karnak Chemical Co. "No. 81" or Gibson -Homan "(Vo: 6160" cold applied adhesive at 1 -1/2 gal /sq. Membrane: One layer of "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule), hot mopped or adhered with Karnak Chemical Co. "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive at 1 -1/2 gal/sq. 20. Deck: C- 15/32 Incline: 1/4 Insulation: Polyisocyanurate, any thickness. Base Sheet " GAFGLAS #75" (Type G2), mechanically attached. Membrane: One or more plies of "Rubberoid Torch (smooth). Membrane: "Ruberoid Torch 170FR" (granule). 21. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Polyisocyanurate, wood fiber, perlite, glass fiber any thickness, hot mopped or mechanically fastened. Base Sheet: One or more plies of Type G2 " GAFGLAS #75" or "Ruberoid 20 FR" base sheets, hot mopped or mechanically fastened. Membrane: One or more plies of "Ruberoid 30 FR" hot mopped in place. 22. Deck: C -15/32 Incline: 1 Insulation (Optional): Polyisocyanurate, wood fiber, perlite, or glass fiber any thickness, hot mopped or mechanically fastened. Base Sheet One or more plies of Type G2 " GAFGLAS #75" hot mopped or mechanically fastened. 1999 Roofing Materials and Systems Directory 24. 25. 26. 27. 28. 29. 30. 31. 32. LOOK FOR THE UL MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU) — Continued Ply Sheet: One or more plies of "Ruberoid 20" or "Ruberoid 20 FR ", hot mopped in place. Membrane: One or more plies of "Ruberoid 30 FR ", hot mopped in place. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Fiber glass or perlite, mechanically fastened. Base Sheet One or more layers Type G2, hot mopped or mechanically fastened. Ply Sheet: Two or more layers Type 61, hot mopped or mechanically fastened. Membrane: "Ruberoid 30" or "Ruberoid Modified Cap Sheet 601 ", hot mopped in place. Deck: NC Incline: 1/4 Insulation (Optional): Polyisocyanurate, perlite, glass fiber or wood fiber, 2 in. max. Base Sheet: Type 15 asphalt organic felt, Type G2 or "Flex Base 60" (modified bitumen), mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid® Torch 1" (modified bitumen). Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" or "Karnak No. 97 Asbestos Free Aluminum Roof Coating" at 1 to 2 gal /sq. Deck: C -15/32 Incline: 1/4 Insulation: Two layers glass fiber (staggered joints), 1 in. each. Base Sheet: Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid® Torch 1" (modified bitumen). Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" at 1 to 2 gal /sq. Deck: NC Incline: 1/4 Membrane: 'Ruberoid® Torch 1" (modified bitumen). Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" at 1 to 2 gal /sq. Deck: NC Incline: 1/2 Insulation (Optional): Perlite, wood fiber or glass fiber, 1 in. max, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: Type G2 or "Flex Base 60" (modified bitumen), mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid® Torch 1 ", heat fused. Surfacing: Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro -Grade Aluminum Roof Coating ", 1.5 gal /sq. Deck: NC Incline: 1/2 Insulation (Optional): Perlite, wood fiber, glass fiber or isocyanurate/ urethane board, 2 in. max, mechanically fastened. Base Sheet: Type G2 (modified bitumen), mechanically fastened or adhered with hot roofing asphalt. Membrane: 'Ruberoid® Torch 1" (modified bitumen), heat fused. Surfacing: Monsey Products "Dura- White ", "Endure White Elastomeric Roof Coating" or "Pro -Grade White Elastomeric Roof Coating ", 3 gal /sq. Deck: NC Incline: No limitation Insulation (Optional): Polyisocyanurate, urethane, glass fiber, perlite, wood fiber, any combination in any thickness, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: Type G2 (modified bitumen), mechanically fastened. Membrane: "Ruberoid® Torch 1 ", heat fused. Surfacing: "Tuff -Corp" field mixed insulating coating composed of 6 -2/3 cu ft of perlite, 7 lb of "TC -500 Masterbatch ", 94 lb Portland cement and 17 gal of water spray applied to min 1/2 in. Deck: C -15/32 Incline: No limitation Insulation (Optional): Polyisocyanurate, urethane, glass fiber, perlite, any combination in any thickness, mechanically fastened. Base sheet: Type G2 (modified bitumen), mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid® Torch 1 ", heat fused. Surfacing: "Tuff- Corp" field mixed insulating coating composed of 6 -2/3 cu ft of perlite, 7 lb of "TC -500 Masterbatch", 94 lb Portland cement and 17 gat of water spray applied to min 1/2 in. Deck: NC Incline: 1/2 Insulation (Optional): Glass fiber, perlite, wood fiber, 1 in. max, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid® Torch 1" (modified bitumen), heat fused. Surfacing: Henry "No. 229 Asphalt Emulsion" at 1 gal /sq or GEO Industries "No. 929 Aluminum Emulsion" at 1 gal /sq. Deck: NC Incline: 1/2 Insulation: Polyisocyanurate, glass fiber, perlite, wood fiber, hot mopped or mechanically fastened any thickness. Base Sheet: Type G2, mechanically fastened or hot mopped. Membrane: "Ruberoid® Torch 1 ", heat fused in place. Surfacing: Henry, "Henry 520 Aluminum ", applied at 1 -1/2 gal /sq.