Loading...
34556Date: - PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 74' 15 Job Address )I3 Pr: o. 4 Tax Folio 1 2/g4' 0 7 Legal Description 5 .01 01 OA Ng * Le f 7' T e l w ngr J) Lessee / Tenant 7Aw$LY Master Permit Q 1-C Owner's Address ) 1306 - ti ■ iIJD. Phone 5 - 5O ' Contracting Co. GdA5 Bata nxiiaJ /e, Address 5 tom+ -'rt. L 400 ,/ 170.. i#Z4 tAMt , 331 Li Qualifier St'a,vrs>a SO Phone .3a,".. U4 -00 State # 4C ooY31¢ Municipal # Competency # Ins.Co. Sara r ,- 33 # zlV Architect /Engineer AG441 l.35soo -t l U-$ Address ' f. LAamILWD.ALM. / 333oi Bonding Company Address Mortgagor Address Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION vtw»J 1: wTie1 Square Ft . • °O Estimated Cost (value) WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indidated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and •ping. Furthermore, I authorize the above -named contractor to do the work stated. , , 'o!Z 411r.vt a L.. (all us, actor or Owner- Builder Signature of owner and /or Condo President Notary as to Owner and /or Condo President My Commission Expires: Sig ature of Con Date* Notary as to My Commission ** * * * * * * * * * FEES: PERMIT' L RADON C.C.F. APPROVED: Fire Zoning Buildin Mechanical Plumbing Engineering NOTARY imaislOsoitratimihridad fe SCOTT W DAVIS * COMMISSION NUMBER 4 C C255237 AT MY COMMISSION EXP. F JAN 26,1987 ** TOTAL DUE 1 Other Electrical rn• 9. ti1140d .' SAS TARY M, H. R . EL. I • - - -�� w I . EL. 3. -•N (6..�. NV. EL. 3 ..7 INV.EL. 3. INV. EL.3. • 9�E(8� i .4 Tif".c': • $: • ,s July 1, 1993 Mr. Ed Cannon Project Engineer ACAI Associates, Inc. 5310 NW 33rd Avenue Suite 218 Fort Lauderdale, FL 33309 -6300 SUBJECT: Analytical Report Barry University Maintenance /Ground Building Chase Construction Site 11300 NE 2nd Avenue Miami Shores, Florida 33161 Atlantic Coast Project No. A -351 Dear Mr. Cannon: SAMPLE NO. MATERIAL 351 -B -1 Plaster/Wallboard 351 -B -2 351 -6 -3. Built -Up Roof Roof Flashing Atlantic Coast Environmental Services, Inc. 8980 DISCOVERY ROAD P.O. BOX 1207 • CAPE CANAVERAL, FL 32920 -1207 407 - 624 -3549 P.O. BOX 387 - DELRAY BEACH, FL 33447 -0387 407 - 272 -9042 LOCATION North End - Closet South - Central SE Corner ` u ACA 1 l On June 29, 1993, I inspected the above referenced facility for the presence of suspect asbestos containing materials (ACM) due to the building being scheduled for partial demolition. Bulk samples of suspect ACM were obtained and analyzed for the presence of asbestos using polarized light microscopy (PLM) in conjunction with dispersion staining. Bulk samples were analyzed by Advanced Industrial Hygiene Services, Inc. Mr. Bruce Marchette, CIH, performed the analysis. The results are as follows: PLM RESULT No Asbestos Detected No Asbestos Detected 5% CHRYSOTILE ASBESTOS RECEIVE. •��►Ss 1993 R REGISTERED ARCHITECT: AR0011378 - AR0012144 • CORPORATE LICENSE: AA- 0002138 • ASBESTOS CONSULTANT: AF0000010- AF0000017 Project No. A351 Barry University No suspect spray - applied materials or thermal system insulation were observed during the inspection. Atlantic Coast recommends the portion of the facility to be demolished be done utilizing wet demolition techniques and the waste disposed of as general construction debris. All demolition and disposal procedures should be in accordance with federal, state and local regulations concerning demolition. If you have any questions or require further information, please contact us at our Delray Beach office. Sincerely, Atlantic Coast Environmental Services, Inc. Lyhn E. Jay, R.A. Florida Licensed Asbestos Consultant AF 0000021 _,. P eter J. aird Vice - President Page 2. Grounds Building Advanced Industrial Hygiene Services, Inc. All Facets of Industrial Hygiene Service Account # 1309 Project # 157 Atlantic Coast Environmental Services P.O. Box 387 Delray Beach, Florida 33447 -0387 Attention: Gary Butler Sample Received: 29/JUN/93 Sample Designation: B ulk s sub mitted for analysis; Analytical Results: ASBESTOS CONTENT Date: 30/JUN/93 Page 3 Sample Log # NVLAP Lab Code 1006 Collected By: Client Rep Sample Analyzed: 30 /JUN /93 Sample # 1309 - 3505 - 1: Client Sample # 351 -B -1 1. Sample Appearance: W outer with brown 2. Was Asbestos Detected? No 3. Is Sample Homogeneous? no 4. Non - Asbestos Fibers: 20% cellulose fibers 5. Non - Fibrous Material: 70% calcite ineral granules 5% paint Cellulose fibers anisotropic, t sign of elongation, R.I. liquid tested: 1.550, Birefringence: medium, Pleochroic, incomplete extinction Advanced Industrial Hygiene Services, Inc. is accredited for asbestos fiber analysis through participation in the NISI National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 dated Friday, October 30, 1987. Accreditation renewal date: April 1 1994. Analytical Method: 40 CFR Ch.1, Pt. 763, Subpt. F, App. A, Pgs. 293 -299, 1 -1 -87 ed.; (Polarized light microscopy in conjunction with dispersion staining) Analyzed By: Bruce Marchette Laboratory: Advanced industrial Hygiene Services, Inc., 2131 S.W. Telephone: (305) 854 -7554 This analysis report is valid for sample # 1309- 3505 -1 only. This report may not be used to claim product endorsement by NVLAP 2nd Ave., Miami, Florida 33129 or any agency of the U.S. Government. Respectfully S mitted, Bruce Marc t e, "H Authorized Signatory AIHS, Inc. 2131 S.W. 2nd Avenue • Miami, Florida 33129 • Tel (305) 854 - 7554 • Fax (305) 285 -0677 Account # 1309 Project # 157 Atlantic Coast Environmental P.O. Box 387 Delray Beach, Florida Attention: Gary Butler Sample Received: 29/JUN/93 I H 33447 -0387 Services Date: 30 /JUN /93 Page # 2 of 3 pages Sample Log # 3505 NVLAP Lab Code 1006 Collected By: Client Rep Sample Analyzed: 30 /JUN /93 Sample Designation: Bulk sample submitted for analysis; Project # A -351 Analytical Results: ASBESTOS CONTENT Sample # 1309 - 3505 -2: Client Sample # 351 -B -2 1. Sample Appearance: Black tarred felts with brown fibrous insulation 2. Was Asbestos Detected? No 3. Is Sample Homogeneous? no 4. Non - Asbestos Fibers: 65% cellulose fibers 5. Non - Fibrous Material: 30% bituminous resins 5% mineral granules Cellulose fibers anisotropic, + sign of elongation, R.I. liquid tested: 1.550, Birefringence: medium, Pleochroic, incomplete extinction Advanced Industrial Hygiene Services, Inc. is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 dated Friday, October 30, 1987. Accreditation renewal date: April 1, 1994. Analytical Method: 40 CFR Ch.1, Pt. 763, Subpt. F, App. A, Pgs. 293 -299, 1-1-87 ed.; (Polarized light microscopy in conjunction with dispersion staining) Note: This sample was ashed at 1000 0 F for two hours. This constitutes a departure from the above method. Analyzed By: Bruce Marchette Laboratory: Advanced Industrial Hygiene Services, Inc., 2131 S.W. 2nd Ave., Miami, Florida 33129 Telephone: (305) 854 -7554 This analysis report is valid for sample # 1309- 3505 -2 only. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Resfectfully Su mitted, • Bru a March te, C Authorized ignatory AIRS, Inc. IH U Account # 1309 Project # 157 Atlantic Coast Environmental Services P.O. Box 387 Delray Beach, Florida 33447 -0387 Attention: Gary Butler Sample Received: 29/JUN/93 Sample Designation: Bulk sample submitted for analysis; Project # A -351 Analytical Results: ASBESTOS CONTENT Date: 30 /JUN /93 Page # 3 of 3 pages Sample Log # 3505 NVLAP Lab Code 1006 Collected By: Client Rep Sample Analyzed: 30 /JUN /93 Sample # 1309- 3505 - 3: Client Sample ,41 351 -B -3 1. Sample Appearance: Black resinous tar -like material 2. Was Asbestos Detected? Yes 3. Is Sample Homogeneous? no 4. Sample Contained: 5% CHRYSOTILE Asbestos 5. Non - Asbestos Fibers: 5% cellulose fibers 6. Non - Fibrous Material: 10% mineral o granules s Chrysotile fibers anisotropic, + sign of elongation, R.I. 1.556, R.I. 1.542, Birefringence: tow, Non- pleochroic, parallel extinction Cellulose fibers anisotropic, + sign of elongation, R.I. liquid tested: 1.550, Birefringence: medium, Pleochroic, incomplete extinction Advanced Industrial Hygiene Services, Inc. is accredited for asbestos fiber analysis through participation in the NISI National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 dated Friday, October 30, 1987. Accreditation renewal date: April 1, 1994. Analytical Method: 40 CFR Ch.1, Pt. 763, Subpt. F, App. A, Pgs. 293 -299, 1 -1 -87 ed.; (Polarized tight microscopy in conjunction with dispersion staining) Note: This sample was ashed at 1000 ° F for two hours. This constitutes a departure from the above method. Analyzed By: Bruce Marchette Laboratory: Advanced Industrial Hygiene Services, Inc., 2131 S.W. 2nd Ave., Miami, Florida 33129 Telephone: (305) 854 -7554 This analysis report is valid for sample # 1309- 3505 -3 only. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Su • itted, Bruce Marche e, CI Authorized Sgnatory AIRS, Inc. Ci L1TY �� RELINQUISHED BY: ffRS G Cacot i — _S E /! i - y r DATE TIME I I RECEtVE9Y: SA M PLER(S) DATE TA RELINQUISHED BY: k20x E DATE TIME I RECEIVED BY: S t saATE1� lJ►B TYPE _ a T BATE AMAIYS S ASBESTOS AApIVE OA T£ Aac1ivER NUMBER ARCO INT*MS SPECIAL INS iAuCTI NS ANALYZED ea ru1S . N A-1 Y , i - c-I 3L X43 + all i . 4-_.3 PIA__.4 - • rilli at Atlantic Coast Environmental Services PROJ. M I PR 01 NAME BULK SAMPLE CHAIN OF CUSTODY RECORD RELINQUISHED BY: I DATE TIME yerA /6;64 RECEIVED BY: ALL SAMPLES WILL BE DISPOSED OF NINETY DAYS AFTER MNALYS /S UNLESS OTHERWISE REQUESTED