RF-10-784• BUILDING PERMIT APPLICATION FBC 2004 Tenant/Lessee Name City Miami Shores Villa e FOLIO / PARCEL # 11- 2136- 000 -0050 Structural Review. $ Miami Shores Village Building Department /0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. p r 1 Q 69 Master Permit No. Permit Type (circle): Building Owner's Name (Fee Simple Titleholder) BARRY UNIVERSITY Owner's Address 11300 NE 2 AVE City MIAMI SHORES State FL Zi 33161 Job Address (where the work is being done) 11300 NE 2 AVE - Dunspaugh County City POMPANO BEACH State FL Qualifier Name JOHN B MITALA State Certificate or Registration No. CCCO57467 Miami -Dade Phone # Is Building Historically Designated YES NO Contractor's Company Name INFINITY ROOFING AND SHEET METAL, INC. Contractor's Address 1150 SW 10TH AVE STE 201W BY: Zip qn Io3CrAx. Phone # 954 -917 -7107 Z i p 33069 Phone # 954 - 849 -4778 Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ Square / Linear Footage Of Work: 4/ ti 7O $,/' J OS O / Type of Work: ['Addition ['Alteration DNew Repai Replace ❑ Demolition Describe Work: Dunspaugh Dormers % ,e®,4- Submittal Fee $ Permit Fee $ /SP CCF $ 1 0 CO /CC Notary $ aining/Education Fee $ 9.A) Technology Fee $ 9 • (PO Scanning $ " 1-0(J Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ q c� y n Total Fee Now Due $ 1 oti() °.:2 See Reverse side -+ Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection whic urs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be appr and a reinspection fee will be charged Signature (Revised 07/10/07) Owner or Agent The foregoing instrument was acknowledged before me this day of A- -pp „( ,20 16 , by g'rwe4e E3i r3, s who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Si Print: 1. M Commission Expires: APPLICATION APPROVED BY: Signature t1 �, Contractor The foregoing instrument was acknowledged before me this 5 day of Mt/ , 20/t0 , by JOHN B MITALA who i personally known to me r who has produced as identification and who did take an oath. OTARY P IC: JAVIER MARTINEZ it t S1tF � Notarfl'u - •F My Comm. Expires Jun 10, 2013 Commission • OD 698148 LINDA S. MITTS Notary Public - State of Florida • ,,, ,, Tres Jun 16.201 Commission NOD 883031 u Assn. nt: AUJPJ 41 y Com issio Engineer Zoning Gun° 1 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED PERMIT NO OSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION r I il k 1 ' ( { TAX FOLIO NO. 11-2136- STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this yotice of Commencement. pre.prd 5y - 746k kw /5 1 15 0 AM 54 6 6 24 l w Pomp°` aeaC1, .FL, 3 3 06/ 1. Legal description of property and street/address: 11300 NE 2 AVE MIAMI SHORES 36 52 41 40 AC SE1 /4 OF NE1 /4 LESS E35FT & LESS W4OFT LOT SIZE 1740400 SQUARE FEET 2. Description of improvement: Dunspaugh Dormers 3. Owner(s) name and address: BARRY UNIVERSITY, INC. 11300 NE 2ND AVE. MIAMI FL 33161 Interest in property: Name and address of fee simple titleholder: 4. Contractor's name, address and phone number: INFINITY ROOFING AND SHEET METAL, INC. 1150 SW 10TH AVE STE 201W POMPANO BEACH FL 33069 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number: NA Amount of bond $ 6. Lender's name and address: NA 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number: NA 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number: NA 9. Expiration date of this Notice of Commencement: (the expiration date Is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU I 1 TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOT MENCEMENT. Signature(s) of Owner( By Print Name /0 -A.4 Title /Office V , CeSO.cs fc_S f 1r r/Ai STATE OF FLORIDA COUNTY OF MIAMI -DADE The for going instrument was acknowledged before me this s2L, day of By ❑ Individually, or I as II P for ( c - [ ( r a U Ir `1 Personally known, or ❑ produced the following type of identificati n: Signature of Notary Public: . _ rvi Print Name: v ., S: sAA (SEAL) VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it ar _rue, to the best of my knowledge and belief. 123.01 -52 PAGE3 11/07 ' Authorized Officer /Director /Partner /Manager By Print Name Title /Office 111111111111111111111111111111111111111111111 CFN 2010R0308947 OR Bk 27277 Ps 4856; f 1Ps RECORDED '35/10/2010 09 :19:50 I HARVEY RUVINe CLERK OF COURT MIAMI —DADE COUNTY? FLORIDA LAST PAGE Space above reserved for use of recording office - UNDA S. MITTS Notary runnC - State of Florida My Comfn. Explrea Jun 16, 2013 Co nntauton # 0131163031 _ARNO National ., Ann. Signature(s) of Owne'i• ' s)'s Authorized Officer /Director /Partner /Manager who signed above: By ` By Inspection Number: INSP- 142425 Permit Number: RF -5 -10 -784 Scheduled Inspection Date: November 05, 2010 Inspector: Bruhn, Norman Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Dunspuagh Hall Miami Shores, FL 33138 -0000 Project: <NONE> Contractor: INFINITY ROOFING AND SHEET METAL INC Building Department Comments DUNSPAUGH DOMERS REMOVAL Passed f/, Failed Correction Needed Re- Inspection Fee November 04, 2010 No Additional Inspections can be scheduled until re- inspection fee is paid. Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspector Comments For Inspections please call: (305)762 -4949 Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1121360010160 -16 Phone: (954)917 -7107 Page 2 of 7 1 r HI ©H- VELOCITY HURRICANE ZONES • • -'aD BY DA I B • • 0!NNG DEPT B EPT SUBJECT 10 CCMPLIANCE WITH ALL FEDERAL STATE AND CC -UN - 1Y HULES AND REGULATIONS 'Design Calculations per Section R4403, or If Applicable, RAS 127 or 'RAS 128 � ��ii ��,yy...����� COOT Can ' nt.Predir t 1'` roy.4iae MAY 0 6 391 HIGH- VELOCITY HURRICANEE ONES 4 UNIFORM PERMIT APPLICATION INSTRUCTION .PAGE COMPLETE THE NECESSARY SECTIONS Of THE UNIFORM ROOFING. PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS : AS NOTED BELOW: ATTACHIVIENTS . REQUIRED: Fire DinactorY Ling Page From Pod d# Approval: Piont Page Speoofia• SWIM ptiOn . gpecilka System LbnitalObros General Limibationg Applicable DOA Drawings FLORIDA BUILDING CODE — RESIDENTIAL 000000 • • • ..... • :t a r in k�liiliii'��yr� *lobar Pormittle Proms No. v Con o s.N te. i4i; Jf ua�h 07 She -pia* Job //30 ,(J .2nd �. site, //1441/4,4,, s alh ROOF CAMORY u,., sue: ni: d: . do . D . 0 M .P r C3 m ew Rea Low lfloof . Mot . FLORIDA BUILDING CODE RESIDENTIAL 9 1, eating a g OOOO Retook a 0tif ReCig" 400 ,s - /A • • HIGH - VELOCITY HURRICANE ZONES • ,. •••• • ••; • • • • • .. .• •. .• • • • • • • 44.21 • • ...••• • • ...•.• • • • • •• • • at , 200 f j Eurr p'A Sec"1nD'o t); 3 11 '44 77' W elev Wean Root g ft 227 FT • .. • • • • ... • • . • • .. • Roof Ste: 4 type: FLORIDA BUILDING. CODE — RESIDENTIAL / "x HicHVELDCny HURRICANE ZONES rigo HIGH - VELOCITY HURRICANE ZONES 44.24R A th t ,.. R � l� a� �X `e ; %rad 040t4ittlitaik* t Sit i t*41101 1 : ik " t . e , ,. '+ r ► - . •: • i( ; • 1 x. 0- � l 6 � U :/ . / Product Approval M, 7° 1 • (f ^ �. � �. 1�6 - Md. i .S & Product Approval • (P :. r r ';at1 *4S J fle )- Ma..7:•Fa 7' ProductApprov 117, �b Wiled 0 e • ,: oti .P,e Ta w • `Rcritiircd'Mateo ef' #ctaucc From Ts* CO* Product Approval Mr Wit. e i cau itch a 41,Aive 4k. , F :vim bawl 1lle ns d..3- - i r 1 :"I x F � r:v :than !i i . a IPJTIFI , t the:° ka#3 trrt+ n • ed tY B I I PeM1 ' '� _ r a ~i: _ , -, ,_ :e t VI►e _, -. x = _.._._ �;.. PraductApproval F . . ";; Js �* ti�3 s XCro '''' r , .—._. Product Approval F Product Approval F 'kto :ta ■ Where , find ,prate ;. • • ...... • • • • M I A M I.DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Entegra Sales, Inc. 819 S. Federal Highway, Suite 300 Stuart, FL 34994 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reservejlfe'fight to have this product or material tested for quality assurance purposes. If this product or m4terigt fails to yetfonn in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may lately revoke, modify, or suspend the use of such product or material within their jurisdiction. VOW reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division t this p 4uct or material fails to meet the requirements of the applicable building code. • • • •••• • •••• This product is approved as described herein, and has been designed to comply with the H % ocity !11fic1ne • Zone of the Florida Building Code. •••••• • • • • • • • DESCRIPTION: Skandia Roof Tile • • • • •••• LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state add . • • • following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 00- 1106.03 and consists of pages 1 through 6. The submitted documentation was reviewed by Jor L. e lm s MIAMI -DARE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 • NOA No.: 05- 0413.01 Expiration Date: 12/08/10 Approval Date: 12/08/05 Page 1 of 6 • • • •••• • ••••• • • • • ROOFING ASSEMBLY APPROVAL Category: Sub Category: Material: 1. SCOPE This renews a roofing system using Entegra " Skandia" concrete roof tile, as manufactured for Entegra Sales, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Skandia. Skandia ABC Duratile USA "E" USA Trim Pieces 2.1 COMPONENTS OR PRODUCTS MANUFACTURED BY OTHERS Product Tile Nails Tile Screws Rainproof II Ice and Water Shield TU Underlayment Roofing Roofing Tiles Concrete Dimensions Length: 161/2" Width: 13" Length: varies Width: varies Thickness: varies Dimensions Min. 10dx 3" #8x 2 V" long 0.335" head dia. 0.131" shank dia. 0.175" screw thread dia. 30" x 75' roll 36" x 75' roll 60" x 75' roll 36 "x75' roll 39% "x32'10" roll Test Specifications TAS 112 TAS 112 Test Specification s TAS 114 Appendix E TAS 114 Appendix E TAS 104 TAS 103 TAS 103 Product . •• •••• • •.• Flat concrete roof tile for direct deck'oj • batten nail -on. • • Product Description Accessory trim, concreto, suoftieces for ; • • use at hips, rakes ridges and •ey • • • • terminations Corrosion resistant screw or smooth shank nails Corrosion resistant, coated, square drive, galvanized, coarse thread wood screws Single ply, nail -on underlayment with 2" self adhering top edge Self - adhering Underlayment Self - adhering Underlayment Descrip4on. • •••• ••• • • • • • • •••• •••• • • • • • • • • • • .• • • • • Manufacturer Generic (With current NOA) Generic (With current NOA) Protect -O -Wrap, Inc. W.R. Grace Co. Polyglass USA, Inc. .. • • .• .• NOA No.: 05- 0413.01 Expiration Date: 12/08/10 Approval Date: 12/08/05 Page 2 of 6 • • • •.•.•• • • • • • • • • • Roof Tile Mortar ( "TileTiteTM") Roof Tile Mortar ( "Quickrete® Roof Tile Mortar #1140) Roof Tile Mortar ("BONSAL® Roof Tile Mortar Mix) Roof Tile Adhesive ( "Polypro® AH 160 ") Roof Tile Adhesive ( "Tile Bond ") Hurricane Clip & Fasteners 3. LIMITATIONS N/A N/A N/A Various Factory premixed containers Clips Min. l /a" width Min. 0.060" thick Clip Fasteners Min. 8d x 1' /a" TAS 123 Prepared mortar mix designed for mortar set roof file applications TAS 123 Prepared mortar mix designed for mortar set roof tile applications TAS 123 Prepared mortar mix designed for mortar set roof tile applications See NOA Two component polyurethane adhesives designed for adhesive set roof tile applications See NOA Single component polyurethane adhesives designed for adhesive set roof tile applications TAS 114 Appendix E Corrosion resistant clips with corrosion resistant nails. Bermuda Roof Company, Inc. Quickrete Construction Products W.R. Bonsai Co. Polyfoarn Products, Inc. Flexible Products • • • • Heneric •••• • • � • • 1� curr i • •••:•QOA) •• • • •••• • • • • • •• • • ••••• • •••• • • •• •• 3.1 Fire classification is not part of this acceptance. • • 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with RAS 106 may required, refer to applicable building code. • • • • • 33 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to • • • • perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30190 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 "Entegra Sales Inc. Skandia Flat and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,119, & 120 4.2 Data For Attachment Calculations • NOA No.: 05- 0413.01 Expiration Date: 12/08/10 Approval Date: 12/08/05 Page 3 of 6 • • • •••••• • • • • • • • • • • Table 3: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) For Nall-On Systems Tile Profile Fastener Type Direct Deck (Min 15/32" plywood) Direct Deck (Min. 19/32" p 1 y wood: •• • ' ; Battens • • • . • • 1 Skandia 2 -10d Ring Shank Nails 30.9 38.1 600 • _ 17. . 1 -10d Smooth or Screw Shank Nail 7.3 9.8 - ;,,, 4.9.... '.••• 2 -10d Smooth or Screw Shank Nails 14.0 18.8 ...... ..' • 7.i..:• • • • 1 #8 Screw 30.8 30.8 :•01,0: 18.2 • ' 24.4...: 2 #8 Screw 51.7 51.7 • 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2. 22.1 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nalls 50.3 65.5 48.3 1 Installation with a 4° tile headlap and fasteners are located a minimum of 2W from the head of tile. Table 4: Attachment Resistance Expressed as a Moment Mf (ft -Ibf) For Two Patty Adhesive Set Systems Tile Profile The Application Minimum Attachment Resistance Skandia Adhesive 31.3 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weights per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 2: Restoring Moments clue to Gravity - M (ft-Ibt) Tile Profile 3" :12" 4 ":12" 5 ":12" : 6 " 12" 7 ":12"or greater Battens Direct Deck Battens Direct , ir� Battens Direct Deck Battens Direct Deck Battens Direct Deck Entegra Skandia 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 N/A NOA No.: 05- 0413.01 Expiration Date: 12/08/10 Approval Date: 12/08/05 Page 4 of 6 • • • • • 000000 • • ..•••• • • • • • Table 1: Aerodynamic Multipliers - X (ft Tile A, (ft3) X (ft3) Profile Batten Application Direct p cation Skandia 0.267 0.289 NOA No.: 05- 0413.01 Expiration Date: 12/08/10 Approval Date: 12/08/05 Page 4 of 6 • • • • • 000000 • • ..•••• • • • • • Table 4A: Attachment For Single Resistance Expressed as a Moment Patty Adhesive Set Systems I Tile Application - Mf (ft-Ibf) Minimum Attachment Resistance Tile Profile Skandia PrOTM . PoIyProT"" — 40.46 La • e • - dd ' Iacement of 45 rams of • Po l ron". 5 ' Medium paddy placement of 24 grams of PolyProTM. !' Table 4B: Attachment Resistance Expressed as a Moment - Mf(ft -Ibf) for Mortar Set Systems Tile Profile Tile Application See specific mortar manufacturer's Notice of Acceptance. Attachment Resistance 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name o t6 , • or following statement: "Miami -Dade County Product Control Approval... • • • • • 5.2 Entegra Sales Inc., Skandia Roof Tile bears the following markings? 5' Ilia, Ska$dia ABC, Duratile, USA "E" USA, where the E is a stylized logo. • ..•• • • • • • •••• 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the fo1.l iag: • • • 6.1.1 This Notice of Acceptance. •••••• 6.1.2 Any other documents required by the Building Official or applicable Bd lding' Code in order to properly evaluate the installation of this system. ; •' • • .. • • 7. MANUFACTURING LOCATIONS 7.1 Indiantown, FL .. • • • • •.. NOA No.: 05-0413.01 Expiration Date: 12/08/10 Approval Date: 12/08/05 Page 5 of 6 • • • •••••• • • • • • • • • • • • • • PROFILE DRAWING SICANDIA FLAT CONCRETE TILE SKANDIA END OF THIS ACCEPTANCE NOA No.: 05- 0413.01 Expiration Date: 12/08/10 Approval Date: 12/08/05 Page 6 of 6 MIAMIDADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested•for gg'i ality assurance purposes. If this product or material fails to perform in the accepted manner, the.*malaufacturer nittncur • • the expense of such testing and the AHJ may immediately revoke, modify, or suspend the �'se of suchiyru&t or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is Attrimined by13CCO • • that this product or material fails to meet the requirements of the applicable building code. ... •••• • Zone of the Florida Building Code. • •..••• This product is approved as described herein, and has been designed to comply with the Hid,, VeJlocity Hurricane • • • •• •• DESCRIPTION: Polypro® AH160 RENEWAL of this NOA shall be considered after a renewal application has been filed ancCITe as be ap. • change in the applicable building code negatively affecting • the performance of this product. ' • • • • TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.01- 0521.02 and consists of pages 1 through 7 The submitted documentation was reviewed by Jprge L. Acebo. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 • • • • • • • • NOA No.: 06- 0201.02 Expiration Date: 05/10/11 _Approval Date: 04 /13/06 Page 1 of 7 ••.••• • • • • • • • ROOFING ASSEMBLY APPROVAL: Category: Sub Category: Materials: SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® Ali 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications • •.. • • Polypro® AH 160 N/A TAS 101 Two component polyuthsn4 foam... • • adhesive Foampro® RTF1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment • • • PRODUCTS MANUFACTURED BY OTHERS: list moment resistance values with the use of Polypro AH160 roof tile adhesive. • • • • •• • PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Roofmg Roof tile adhesive Polyurethane Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results • • • .. .. 1.6 lbs. /fl. 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft 3.1 Perm / Inch +0.07% Volume Change @ -40 F., 2 weeks +6.0% Volume Change @158 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. • •••• • • •••• ••. • • • • • • • • Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which • • •••• • • ••• • NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 2 of 7 • • • .•.••• • • • • • • •...• • • • • • • EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AII160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro their tile assemblies shall test in accordance with TAS 101. W 2 F MS Test Identifier #94 -060 257818 -1PA 25- 7438 -3 25- 7438 -4 25- 7438 -7 25 -7492 NB -589 -631 9637 -92 01- 6743 -011 01- 6739- 062b[1] 7050.02.96 -1 528454 -2 -1 528454 -9 -1 528454 -10 -1 520109 -1 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 520109 -2 -1 Test Name/Report TAS 101 TAS 101 SSTD 11 -93 SSTD 11 -93 SSTD 11 -93 ASTM D 1623 ASTM E 108 ASTM E 108 ASTM E 84 TAS 114 TAS 101 TAS 101 TAS 101 0 Date 04/08/94 12/16/96 10/25/95 11/02/95 12/12/95 02/01/94 04/30/93 11/16/94 01/16/95 03/14/90 • •••• • •••� 10/23/98. •••••• • • •••• •••• • /1/ x/28/98'.... • • • • • • •• • •• •• • • • • • • • • • • . .•.•• • • 1••• • • • •••• AH 160 roof tile adhesive with 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. 1 rF NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 3 of 7 • • • • • • • • • • Table 1: Adhesive Placement For Each Generic Tile Profile • ... • • • Two Pdddrifieight per pakry • (girarfis3 • N/A • • Tile Profile Placement Detail Single Paddy Weight Min. (grams) Flat, Low, High Profiles #1 35 High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan 24 • N/•A • N/A • ' Flat, Low, High Profiles #2 Flat, Low, High Profiles #3 8 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polyproe AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polyprog AH160 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTFI000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after ••••• Polypro® AH160 has been dispensed. • • • •••• 9. Polypro® AH160 placement and minimum patty weight shall be in accordance wittrthe:Placepienr Details' herein. Each generic tile profile requires the specific placement noted hereifi; • • • LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. •• • •• • • • • • • • • • • • • • • NOA No.: 06- 0201.02 Expiration Date: 05 /10 /11 Approval Date: 04 /13/06 Page 4 of 7 • •• •. • • .• • • •� ••• • • • Nan through plastic COMM Undadapnent 1) Place enough adhesive foaddeve17to23 Optional TA's tor square Was In contact with the pan tie ameppftch aPilkaGens 2) Turn covers n Pbce adhesive 112In` To 1 In. From outside �/ edge of cover file. Then install the tne. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY . ••• • • • . . • • • •••• •••• • . • • •••• •••• •••• • • . • • .. • .. . . • • • .. • • • • • . • • • • .. • •••• • • .... NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 6 of 7 • • • • • • • • • • Nall through plastic cement M. x3In. Single paddy on under- layment Single paddy on top of tile Single paddy under tale Paddy (between tie) Paddy (under tile) Eave course 2 in. X 7 in. medium size paddy eave Fascia course only Nail through plastic cement • in.x3In. Single paddy on Underlayment Single pay on top of tile ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Eave Cain Nall through plastic cement Underlayment }in.x 3 in. Single 4 ht. paddy on under - layment Single paddy under tile Single paddy between tile 21n. x 7 h►. medium size paddy eave course only Single paddy on top of tile Eave Cause Fascia Weephole Eave closure Dpedge • Single paddy between tle Eave Closure 21n. x 7 in. medium she paddy eave course only Fascia END OF THIS ACCEPTANCE • • • • • •• • • • • • • • • •• •• • • • • • •• • •• •. •••• • • • •• • • • • • • • • • •••• • • ••• • NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 7 of 7 • • •• • • • • • • •• • • • • •••• • • • • •••• • • • • •• • • • MIAM1•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements Af. the applicable building code. ' • • .••• • • • .. • • • ... This product is approved as described herein, and has been designed to comply with4he Florida guikfng Code and the High Velocity Hurricane Zone of the Florida Building Code. • DESCRIPTION: Polystick P, Basik, IR/IRX, TU TU PIu TU Polyester and Mly�nierlayt ;nth• • LABELING: Each unit shall bear a permanent label with the manufacturer's name orl city, s tag • and following statement "Miami -Dade County Product Control Approved ", unless olWi$e noted herein. • • • • RENEWAL of this NOA shall be considered after a renewal application has been fife t Ind there hoc,. been no change in the applicable building code negatively affecting the performance of this products • • • • TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 06- 0505.01 and consists of pages 1 throu 6. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOA No.: 07- 1025.10 Expiration Date: 09/13/11 Ap proval Date: 04 /10/08 Page 1 of 6 ROOFING COMPONENT APPROVAL Category: Sub - Category: Material: PRODUCTS DESCRIPTION: Product Polystick P underlayment Polystick Basik underlayment Polystick IR/IRX underlayment Polystick TU underlayment Polystick TU Plus underlayment (Facer of Membrane Labeled in Orange or Black Ink) Polystick TU Polyester Polystick MU underlayment Test Dimensions Specification Roll: 75' x 3' 40 mils thick Roll: 65'8" x 3'3 - / 60 mils thick Roll: 65'8" x 3'3 - / 80 mils thick Roll: 32' 10" x 3'3 - / 100 mils thick Roll: 65'8" x 3'3 80 mils thick Roll: 32'10" x 3'3-3/8" 130 mils thick Roll: 65'8" x 3'3- 80 mils thick Roofing Underlayment SBS , APP Self - Adhering Modified Bitumen Product Description ASTM D 1970 A polyethylene top surface, self - adhering, SBS polymer modified bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. ASTM D 1970 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use an underlayment for metal roofing. TAS 103 and A fine granular /sand top surface self- adhering, ASTM D 1970 APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies' • • • . Designed as an ice & rainshieltiand as a?at roof • tile underlayment. • • • • • • TAS 103 and ASTM D 1970 • • • • A heavy granuled surface,dhering, ARP polymer modified, fiberglass.oseolyester• • • • reinforced, bituminous sheetnnaterial for We as an underlayment in sloped'R,t7flisemblit §: • • Designed as a a roof tile uMeflAyment. ' • • • TAS 103 and A non - wicking fabric surfer 41f- adl{pring, ASTM D 1970 APP polymer modified, filderglass reinfMeedwith a high strength polyester fdhrics, lituminousloh.eet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. TAS 103 A rubberized asphalt waterproofing membrane, glass- fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. TAS 103 and A non - wicking fabric surfaced, self - adhering, ASTM D 1970 APP polymer modified, fiberglass reinforced, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. NOA No.: 07- 1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 2 of 6 EVIDENCE SUBMITTED: * Test Agency Test Identifier Test Name/Reoort Date Exterior Research & Design, LLC #11756.04.01 -1 TAS 103 04/27/01 #11756.08.01 -1 ASTM D 1970 08/14/01 #02202.08.05 TAS 103 08/29/05 Trinity I ERD #P5110.08.07 TAS 103 08/29/07 PRI Asphalt Technologies PRI01111 ASTM D 4977 04/08/02 PUSA-005 -02 -01 ASTM D 4977 01/31/02 PUSA -018 -02 -01 ASTM D 2523 07/14/03 PUSA -035 -02 -01 TAS 103 09/29/06 PUSA -033 -02 -01 ASTM D 1970 01/12/06 Momentum Technologies, Inc. JX20H7A ASTM D 4798 04/01/08 ASTM G 155 INSTALLATION PROCEDURES: Deck Type 1: Base Sheet: Fastening: Membrane: Surfacing: Wood, non - insulated, new construction One or more plies of ASTM D 226 Type II or ASTM D 2626 or Polyprotector UDL or Polyprotector UDL AS. Nails and tin caps 12" grid, 6" o.c. at laps. (for base sheet only) Polystick membranes self - adhered. None • • • • • .. • .. • • • • .... • • • • • • .. • • 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten •••• aose ddckiug• panels, and sweep the deck thoroughly to remove any dust and debris prior to appliftion. ... • 2. Place the underlayment over metal drip edge in accordance with RAS 111. •' •' • 3. Place the first course of membrane parallel to the eave, rolling the membrane tts obtait maximum. contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-Y2" and end laps shall be a minimum of 6." Roll the membrane into place after removinglbh• . release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be M nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 07. 1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 3 of 6 Tile Profile Polystick IR/ RX Polystick MU . a 0 Polystitk TU, TUplas: '1'tolyester • • P] g _ !i. C ation . .. Flat Tile 5:12 No limitation Profiled Tile Prohibited 5:12 lYQ lit'iitation .... ■ GENERAL LIIVIITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick P, Basik and 1R/IRX may be used in asphaltic shingles, wood shakes and shingles, non- structural metal roofing, and quarry slate roof assemblies. Polystick P and Basik shall not be used as roof tile underlayment. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. S. Polystick membranes shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polystick P, Basik, IR/IRX, TU, TU Polyester and MU Underlayments shall not be left exposed as a temporary roof for longer than 30 days after application. Polystick TU Plus shall not be left exposed as a temporary roof for longer than 180 days after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice. Polystick TU, TU Plus and MU may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR/1RX is limited to mechanically fastened roof tile applications. Polystick TU Polyester may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. The maximum roof slope for use as roof tile underlayment for ( direct -to -deck) tile assemblies shall be • as described below: • • i n e above slope limitations can be exceeded only by using battens and counter battensinrdance • : • • with the Approved Tile System Notice of Acceptance and applicable Florida Building care • • • requirements. . 9. are should be taken during the loading procedure to keep foot traffic to a minimum a • rid to atei • . • • dropping of tile directly on the underlayment. Refer to Polyglass Tile loading detajfor•,loading.... procedure. • • 0 H 6 Roofing Tiles (6 Max. Per Stack) 12 .. NOA No.: 07. 1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 4 of 6 • • • • • • • • • • .• • • 1 GENERAL LIMITATTIONS: (CONTINUED) 10. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick P, Basik, llUIRX, TU, TU Plus, TU Polyester & MU may be used with any approved roof covering Notice of Acceptance listing Polystick P, Basik, IR/IRX, TU, TU Plus, TU Polyester & MU as a component part of an assembly in the Notice of Acceptance. If Polystick P, Basik, IR/1RX, TU, TU Plus, TU Polyester & MU is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All nnmbranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement 'Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. • "" • 2. Any other documents required by the Building Official or applicable building code ut®xde to prgpedy: evaluate the installation of this materials. • • • • POLYGLASS GENERAL A P P L I C A T I O N G U I D E L I N E S F O R POLYSTICK M E M B R A N E ' . • • • 1. Polyglass does accept the direct application of Polystick underlayment membrannS td Abod do�c'Ic' • Installers are cautioned to refer to applicable local building codes prior to direct Ucli installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets Of di; corresponding products. 2. All rolls, with the exception of Polystick TU Plus and Polystick MU should be bade - nailed in .• "' • selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus and Polystick MU should be back nailed in designated area marked "nail area, area pare clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet /Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick Basik. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. NOA No.: 07 1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 5 of 6 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6 ' /a "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty Eight (48) Hours. 8. Polystick TU Plus, Polystick MU may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Idide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished request. It is recommended to refer to applicable building codes prior to installation to verify •••• . . • • acceptable substrates. • • • • • • • • • • • • • • 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polysti4 I l • • ranes and„ • • • PolyProtector UDL can be furnished upon request by our Technical Services Deggrpent by • • •. • • calling 1(800) 894-4563. • • • • 13. Polyglass offers a 10 year Limited Material Warranty on all properly installed Pblis'tFa c self-. •: •. • adhered underlayments. Warranty must be requested and registered by Polyglass tote in force. • • • 14. Questions in regards to the application of Polyglass products should be directedto ourlrechucj ,, ,; • Services Department at 1 (800) 894 -4563. • • • • • 15. Polyglass recommends that applicators follow good roofing practices and applicable procedufes•as.' • • outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 07.1025.10 Expiration Date: 09/13/11 Approval Date: 04/10/08 Page 6 of 6 SECTION 1524 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section.. The provisions of Chapter 15 of the Florida Building Code, Building govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the own � . the contractor. The owner's initial in the adjacent box indicates that the item has been explained. 1. Aesthetics Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Buiiding•code provietes the • option of maintaining this appearance. •• • • ••• • • • • • •• • . Ponding Water: The current roof system and/or deck of the building ma•roottdrain well and may • cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an •iwd'icgtion 91 ttit,ptural • • distress and may require the review of a professional structural engineer. Ponding•may shortet•ttie life • • expectancy and performance of the new roofing system. Ponding conditions may not beptdett untilitil,egginal roofing system is removed. Ponding conditions should be corrected. •• •• '• • • • • Overflow scuppers (wall outlets): It is required that rainwater flow off so that the 7ppf i not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may blp4if this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow sttipptrs in pettifti nce • with the Florida Building Code, Plumbing. "" We e Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to con 'der additional venting which can result in e din, the service life of the roof. Owner's /Agent's Signature 11300 NW 2ND AVE MIAMI SHORES Rev:1/20 /2005,Computer Services, Building Department or, OS/ 12010 Date Property Address Permit Number ontracto s nature • • •