Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
45331
Date Legal Description PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Job Address 131 E �°� e, Tax Folio Historically Designated: Yes No Owner/Lessee / Tenant 6 t` e \l ULY e t s ;i7 £ P b,r:S x icl Master Permit # Owner's Address t vANI E A � e. Phone g o..r ?kcI.°1 - 3 9 Contracting Co. flotiAzt Stair C dl t Sat-t.)34 Qualifier boActtel o Lwabe4'1 State # EF& 106, 3 Municipal # Competency # Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING 1 LECTRIICA PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Z-15 /(. Fo c 3921 SkJ 47 &vie ?33/4 ss# - -/%/ Phone / sit-7 9/-/3/ 3 Address Arm Sys ► Square Ft. Estimated Cost (value) � 3 i .f WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. e of owneyand/or Condo 'resi +ent Date Notary as to Owner and/or Condo President Date My Commission Expires: , DENISE PLACE COMMISSION # CC 664456 0 EXPIRES JUL 16, 2001 BONDED THRU PO ATLANTIC BONDING CO., INC. FEES: PERMIT k' 345 RADON APPROVED: Zoning Mechanical Notary as to Contractor or Owner - Builder My Commission Expires: Y C.C.F. / - O t NOTARY TOTAL DUE Building Electrical DENISE PLACE t■5MMISSION # CC 664456 Y I Es JUL 16, 2001 RoNDED THRU Al AWN! ROt4DING CO. INC Date Plumbing Engineering • SERER RELAY SOUR GAS ;NOUM TO EUIL DING PERMIT APPLICATION (AN A?_LIC_ ION 1C3 BUILDING PERMIT KIST .1CCOANT =S ADDENDUM. IF A MASTER ?ER= HAS 3- O3T ::NRD, = OWNER'S NOTAR. ZI £ .:Q T .Z NEED NOT BE PRESENT NT ON SUBSEQUENT A2PLICATTONS.) • INDIRECT YAISTES F IRE SPR DICER • HEATER -NEST LAWN RINKR._L - aL S7111111NG POOL SERV ICE SIZE IN A PS ScRVICE REPAIR/IETER =IC c 10TCRS OVER 3- 5 HP 113T1RS OVER 8- 10 HP 113TCRS OVER 10- 25 If AIR CkOIT1ONERS SIGN TIME CLOCK FIXR3RES VIOLATION RERIEE RATION PRO SS AO PRESS PIPING )OT HATER BOILERS lEG`IANICU. VENTILATION FIRE SFRIIH MLR SYSIE S ITE51 BATH TU3 8IOET B ISAYIAS'S DISPOSAL DR INK DG FOUNTAIN FLOOR CHAIN GREASE TRAP INTERCtPTOR CLOTHES BASER SHOYIER S110. POT/3 CIF. SINK. RES109a SINK. TEMrFORARY KATE a..MT t RINAL WATER WAT!!R SLPPLY UT IL ITY- SETTER UT IL TTY- NAATE:I SEPTIC TANK ORAINFIEID. PLUMBING PU1P & ABANDON Sc T1C TAM( SOAKAGE PIT CI. F T. CATOi BASIN 0ISC-IARGE COEST IC AREA CRA ROOF INLET F IRE STANT POOL PIPING LAWN SPRINKLER STST i METER Sc. iI (GAS) GAS P IP DC ELECTRICAL MECHANICAL FE! 0 M NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Nt Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. ►i j 1. Legal description of property and street addre s: 4 2 z.L-/ ,2L)J 1/WAS 17 . %'gZ.Nt ✓ PA/ K.,/ , S 3D0 It d� M � ' S„�� �S sue . / I 0. 2. Description of improvement: *,•C f/44 3. 3. Owner(s) name and address: 9714M/ /2/✓/ // 4 Y //1 A %� Z`" )'t4 / e 1 .S!'71/ S / ,C1- '.'l ( / Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: C1 O/ / 94- g ; 7 7 Z• .SLR 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $_ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Far la's rr+i ()4 t Vers.t �N SigAiture of Oe1 er Print Owners Name Fecto(tf E . M I I•a An" "f .co t! {T,e s Sworn to and subscribed before me this p 1 day of •...XCLAINQ., 19 . Notary Public Print Notary's Name EXPIRES (`e "r,, •r er inn Pnvr, • Address: 'Y13 t W;it` E COMMISSION # CC 4644 IRES JUL 16, 2001 BONE H TRU +` OF ATLANTIC BONDINC CO., INC. STATE OF FLORIDA, COUNTY OF DADE HEREBY CERTIFY that this Is a trace copy of the original filed in this office on Q GCr dc of VSO —7 0. - 77 - 37 ➢93 WITNESS my HARRVEY 8 y nd and Official S K, of Circuit andCount7 Court - Prepared by: Q 5 �►.1SCVVh.2.i a-c' 4M l>. • NOTIFIER A Subsidiary of Pittway Corporation November 21, 1996 A -103 AFP -400 Analog Fire Panel Release 2.0 Section: Intelligent Fire Alarm Control Panels GENERAL The AFP -400 is a compact, cost- effective, intelligent fire alarm control with a capacity of 563 points and an extensive list of powerful features. The AFP -400 integrates conven- tional output circuits, such as notification, telephone, and speakers, with the intelligent features of two signaling line circuits (SLC) and 396 intelligent/addressable points. SOFTWARE RELEASE 2.0 FEATURES • The Fire VIEWT'a System: ✓ Revolutionary new spot laser detection. s/ Advanced AWACS"' algorithms differentiate between smoke and non -smoke signals. ✓ Addressable operation pinpoints the fire location. ✓ No moving parts to fail or filters to change. ✓ Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. • New Advanced Multi- Sensor (AMS) detector support. • Expanded sensitivity window: r/ ION — 0.5 to 2.5 %/foot obscuration. ✓ PHOTO — 0.2 to 2.35 %./foot obscuration. ■ LASER — 0.03 to 1.0 %ffoot obscuration. ® s, MULTI-SENSOR — 0.75 to 4.0 %/foot obscuration. • Low pressure CO, support: ✓ Expanded soak timer - 0 to 9999 seconds. ✓ Manual release delay (10 seconds) type ID. r/ "Second shot" monitor module type ID. ✓ Triple -coded notification circuit type ID. • Combo zone. Connect tamper and waterflow detectors to a common monitor module. • Modified California Code, pulsed on time. • Telephone control module type ID. • Simplified UDACT point reporting and programming. • Verification Trouble counter. Trouble indication after a detector verifies 20 times. • Improved VeriFiren' 400: ✓ Look and feel. ✓ Report option. Sort Maintenance Reports by dirty detector, peak value, or alarm level. OTHER FEATURES • Two intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7. • 396 intelligent device capacity (198 intelligent detectors and 198 monitor /control modules). • Up to 68 internal circuits /relays, plus 99 programmable zone output relays for a total capacity of 563 points. • S635 This document is not intended to be used for installation purposes. We try to keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484 -7118 0 N OTI FI E It 12 Clintonville Road, Northford, Connecticut 06472 CS 118/733 MEA 17 -96 -E California State Fire Marshal 7170 - 0028:182 7165 - 0028:181 The AFP - 400 • Intelligent features: ✓ Manual sensitivity adjustment - 9 levels. ✓ Pre -alarm AWACS"' 9 levels. ✓ Day/Night automatic sensitivity adjustment. ✓ Drift compensation (U.S. Patent Pending). ✓ Multi - detector algorithm Involves nearby detectors in alarm decision (patent pending). a/ Auto detector test (meets NFPA 72). ✓ Maintenance alert (two levels). ✓ Self - optimizing pre -alarm adjusts pre -alarm level to environment automatically. ✓ Activate local sounder base on pre - alarm. s✓ LED blink control for sleeping areas. ✓ Automatic device type check. • Releasing features: ✓ Ten independent hazards. ✓ Sophisticated cross -zone (three options). ✓ Delay timer and Discharge timers (adjustable). ✓ Abort (four options). ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Made in the U.S.A. DN -5262 — Page 1 of 10 OTHER FEATURES, continued • Voice and telephone features: ✓ Solid state message generation. ✓ Hard -wired voice control module options (System 5000 class modules). ✓ Distributed voice options (XP transponders). ✓ Fire fighter telephone option. ✓ 30- to 120 -watt high - efficiency amplifier. ✓ Backup tone generator and amplifier option. ✓ Dual channel option. • Optional universal 396 channel DACT, with AC fail delay. • LCD -80 remote 80- character displays (up to 32). • ACS annunciators (EIA -485), including LDM custom. • Printer interface (80- column and 40- column printers). • 6.0 A usable regulated output power, plus 3.0 A ex- panders. • 80- character LCD display, backlit (2 lines x 40 charac- ters). • History file with 800 -event capacity in non - volatile memory, plus separate 200 -event alarm -only file. • VGAS graphic monitor system supports up to 8 AFP- 400's. • Waterflow or supervisory selection per point. • Alarm Verification selection per point, with tally. • Autoprograming and Walk Test reports 2 devices set to same address. • Positive Alarm Sequence (PAS) Presignal per NFPA 72. • Silence inhibit and Auto Silence timer options. • March time /temporaVCalifornia/two -step code for bell circuits. • Field- programmable on panel or on PC, with VeriFireT"" program check, compare, simulate. • Full QWERTY keypad behind flip -down door. • MMX -2 two -wire detector interface provides compat- ibility with many non - NOTIFIER detectors for retrofit applications. • Dual rate charger for up to 90 hours of standby power. • Tomado Warning activates different Notification Cir- cuit code. • Non -alarm points for lower priority functions. • Remote ACK/Silence /Reset/Drill via MMX modules. • Automatic time control functions, with holiday excep- tions. • Rapid poll algorithm for manual stations. Responds in < 3 seconds. • Operates with untwisted, unshielded wire (up to 1,000 feet) for retrofit applications (U.S. Patent 5, 210, 523). • Surface Mount Technology (SMT) Electronics. • High -speed RISC 16 -bit Microprocessor. • Extensive, built -in transient protection. Page 2 of 10 — DN -5262 • • • N OTI FI E R A Pittway Company June 18, 1998 SDX -551 and SDX -551 TH Intelligent Photoelectric Detectors Section: Intelligent/Addressable Devices H -105 GENERAL The SDX -551 and SDX -551TH Analog Photoelectric Detec- tors are used with the NOTIFIER AM2020, AFP1010, AFP - 400, AFP -300, AFP -200, and System 5000 (when equipped with AIM -200 module) Advanced Multiplex Systems to mea- sure the analog level of smoke and report this analog level to the control panel. The use of analog data provides signifi- cant benefits to the end user, installer, and service personnel in ways not possible with a conventional -type system. Since this detector is also addressable, it will help firefighters to more quickly locate a fire during its early stages. The SDX -551TH offers the same features as the SDX -551 with the addition of a 135 °F (57 °C) intemal thermal element. FEATURES • Unique optical sensing chamber. • Optional integral 135 °F (57 °C) fixed - temperature element. • Superior signal -to -noise ratio (2.0). • Stable photoelectric operation. • 1.6% nominal sensitivity for panel alarm threshold level. • Fully coated circuit boards and superior RF /transient pro- tection. • Addressable by device. • Rotary DECADE 01 -99 address switches. • Two -wire loop connection. • Visible LEDs "blink" every time the unit is addressed, and illuminate steadily on alarm (this feature may be deselected on the AM2020, AFP1010, AFP -400, AFP -300, and AFP - 200). • 360° -field viewing angle of visual alarm indicators (2 LEDs). • Integral communications, built -in device type identification. • Compact, stylish design. • Remote test feature from the panel. • Built -in functional test switch activated by extemal magnet. • Low standby current. • Listed to UL -268. • Built -in tamper- resistant feature. • Designed for direct - surface or electrical -box mounting. • Sealed against back pressure. • Optional sounder, relay or isolator bases. • Plugs into separate base for ease of installation and main- tenance. • Separate base allows interchange of photoelectric, ioniza- tion and thermal elements. • 94 -VO plastic flammability rating. • Removable cover and insect screen for field cleaning. • Remote LED annunciator output connection. S1115 93/00141 (SDX - 551) CS308 CSI 18/CS733 (SDX-551A) US Coast Guard 161.002/27/1 161.002/23/1 (SDX - 551) BASES LISTED SEPARATELY. CONTACT FACTORY. Base (order \� separately) Califomia State Fire Marshal 7272 - 0028:148 0Q4AO.AY MEA 460 -92 -E 290 -91 -E BSA 578 -81 -SA (SDX -551) This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484-7118 0 N OTI FI E It 12 Clintonville Road, Northford, Connecticut 06472 ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Made in the U.SA. DN -1884 — Page 1 of 2 APPLICATIONS Photoelectric detectors are often faster than ionization de- tectors in sensing smoke from slow, smoldering fires. Ion- ization detectors are often better than photoelectric detec- tors at sensing fast, flaming fires. CONSTRUCTION These detectors are constructed of LEXAN® in an off -white color. The SDX -551 plug -in series of smoke detectors is designed to commercial standards and offers an attractive appearance. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. INSTALLATION The SDX Series Plug -In Detectors use a separate base to simplify installation, service and maintenance. A specially designed tool allows maintenance personnel to plug -in and remove the sensors without using a ladder. Mount base (all base types) on a box which is at least 1.5 inches deep. Suitable boxes include: • 4" (101.6 mm) square box with, or without, plaster ring. • 3 -1/2" (88.9 mm) or 4" (101.6 mm) octagonal box. • Single -gang box. • For the B524RB orB524B/ base: use a 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box; or 4" (101.6 mm) square box. • When using the SDX with the B501BH sounder base: use a 4" square box (1.5" [38.1 mm] deep). NOTE: Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wir- ing "T -taps" or branches are permitted for Style 4 (Class "B ") circuits. OPERATION Each SDX- 551/SDX -551TH uses one of 99 possible ad- dresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the analog level of its smoke - sensing chamber. If it re- ceives a TEST command from the panel (or a local magnet test), it stimulates its chamber electronics and reports an alarm analog level. It blinks its LEDs when polled, and turns the LEDs on when commanded by the panel. The SDX detector uses the light - scattering principle, rep- resenting the latest in smoke - sensing technology. ARCHITECTURAL /ENGINEERING SPECIFICATIONS For specifications request a copy of the Architect/Engineer Specification Disk, available from NOTIFIER Literature Ser- vices, on IBM format 3.5" 1.44 Mbyte magnetic disk. This disk includes files in both ASCII and WordPerfect® 5.1 formats. WordPerfect® is a registered trademark of the WordPerfect Corporation. Page 2 of 2 — DN -1884 COMMON SPECIFICATIONS • Operating voltage: 15 — 28 V (peak DC). • Current range: 6.5 mA current for visible LEDs latched "ON ". • Detector standby current: 230 pA maximum (no com- munication); 330 pA maximum (with LED blink). • Standby current for B524RB or B524BI: < 700 pA @ 24 VDC (includes detector). • Sensitivity: 1.6% nominal. • Sensor: Photoelectric (light - scattering principle). • Ambient temperature: SDX -551: 0 °C to 49 °C (32 °F to 120 °F). SDX- 551TH: 0 °C to 38 °C (32 °F to 100 °F). • Relative humidity: 10% to 93 %. • Air velocity: 3,000 feet/minute maximum. • Weight: 6 oz. (170 gm.). • BX -501 Base diameter: 6.2" (15.8 cm). • B524RB Relay Base: Screw terminals: Up to 14 AWG (2.0 mm Relay type: Form -C. Contact rating: 2.0 A © 30 VDC resistive. 0.3 A @ 120 VDC inductive. 1.0 A @ 30 VDC inductive. Dimensions: 6.2" (157 mm) x 1.4" (36 mm). • B524BI: Dimensions: 6.2" (157 mm) x 1.4" (36 mm). Maximum: 25 devices between isolator bases. SDX -551TH SPECIFICATIONS Includes 135 °F (57 °C) fixed- temperature thermal element. PRODUCT Model SDX -551 * LINE INFORMATION Description Intelligent Photoelectric Sensor (base ordered separately). Intelligent Photoelectric Sensor with built -in 135 °F (57 °C) fixed- temperature thermal element (base ordered separately). * Order suffix A" for Canadian (ULC) approved devices. Bases... BX-501 Standard U.S. 6.2" diameter mounting base. B501 European style 4" diameter mounting base (without flange). B501BH Sounder base assembly (includes B501 base). B524RB Intelligent relay base. B524BI Intelligent isolator base. Optional Accessories... RA400Z** Remote LED. Mounts to a single -gang box. XR5 Removal Tool. XP-4 Extension Pole for Removal Tool. ** Supported by BX and B501 bases only. SDX -551 TH* • NOTIFIED A Pittway Company H -110 FDX -551 Series Intelligent Thermal Detectors Catalog Section: Intelligent / Addressable Devices April 12, 1995 GENERAL The FDX -551 Series intelligent thermal detector is used with the AM2020, AFP1010, AFP -200, and AIM -200 ad- vanced multiplex systems to measure thermal levels caused by a fire and report the analog level of the thermal mea- surement to the control panel. The use of analog informa- tion provides significant benefits to the end user, installer and serviceman in ways which are not possible with a con- ventional type system. Since this detector is also addres- sable, it will help firemen to more quickly locate a fire dur- ing its early stages. FEATURES • Dual Thermistors. • Rate -of -Rise model (FDX -551 R),15 °F (9.4 °C) per minute • Factory preset at 135° F (58 °C). • Addressable by device. • Direct DECADE 01 -99 entry of address. • 2 -Wire loop connection. • Visible LEDs "blink" every time the unit is addressed: — Optional with AM2020 software revision 5 or higher. — Optional with AFP1010. — Optional with AFP -200. • 360° field viewing angle of the visual alarm indicators (Two LEDs). LEDs illuminate steady during alarm. • Integral Communications and Built -in Device Type Iden- tification. • Compact, Stylish Design. • Remote test feature from the panel. • Built -in functional test switch activated by external mag- net. • Low standby current. • Listed to UL -521. • Built -in tamper- resistant feature. • Designed for Direct Surface or Electrical Box Mounting. • Sealed against back pressure. • Plugs into separate base for ease of installation and main- tenance. S747 This document is not intended to be used for installation purposes. We try to keep our product information up to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484 -7118 rJ N OTI FI E R 12 Clintonville Road, Northford, Connecticut 06472 0Q4A0.AY (FDX -551) 0Q4A7.AY (FDX -551 R) US Coast Guard 161•002/27/0 161.002/23/0 CS630 FDX-551A MEA 460 -92 -E 104-93 -E 290 -91 -E 93/00141 California State Fire Marshal 7270 - 028:150 (FDX -551) 7270 - 028:167 (FDX -551 R) BASES SEPARATELY LISTED. CONTACT FACTORY. • Separate base allows interchange of Photoelectric, Ion- ization and Thermal sensors. • SEMS screws for wiring of the separate base. • 94 -5V plastic flammability rating. • Remote LED output connection to optional RA400Z re- mote LED annunciator. • Optional sounder, relay and isolator bases. • Optional recessed base mounting kit (RMK400). ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Page 1 of 2 APPLICATIONS Use thermal detectors for protection of property. For further information call Notifier for manual 156 -407- 00, Applications Manual for System Smoke Detectors ", which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. CONSTRUCTION These detectors are constructed of Lexan® in an off-white color. The FDX -551 Series plug -in intelligent thermal detector is designed to commercial standards and offers an at- tractive appearance. INSTALLATION The FDX -551 Series plug -in intelligent thermal detector uses a separate base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. A specially designed tool allows maintenance personnel to plug -in and remove the sensors without using a lad- der. Mount base (all base types) on box which is at least 1.5" deep. Suitable boxes include: • 4" square box • 3 -1/2" or 4" octagon box. • Single gang electrical box (except relay isolator base) • Use a 4" square with B501 BH base. • Use a 3 -1/2" or 4" octagon or 4" square box for the B524RB or B524B1 base. NOTE: Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wir- ing "T-taps" or branches are permitted for Style 4 (Class "B ") wiring. OPERATION Each FDX -551 Series uses one of 99 possible addresses on a control panel SLC loop. It responds to regular polls from the control panel and it reports its type and status, including the analog level of its heat sensing elements. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm analog level. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel (de- tector blink is optional on the AM2020, AFP1010, and AFP -200). The FDX -551 Series offers features and per- formance that represent the latest in thermal detector technology. Page 2of2 SPECIFICATIONS Operating Temperature 32° -120 °F Operating Voltage/ Current Range 15 -28 V (Peak DC), 5 mA current for visible LEDs latched on. Detector Standby Current: 150 pA maximum. B524RB or B524 BI: < 700 uA @ 24 VDC (includes detector) Sensor Electronic, Dual Thermistors. Fixed temperature alarm 57° C. (135° F.) Rate of Rise Option 15 °F (9.4 °C) per minute. Relative Humidity 10% to 93 %. Weight 6 oz. (170 gm.) BX -501 Base Dia. 6.2 inches (15.8 cm). B501 Base Dia. 4.0 inches (10.3 cm). B524RB Relay Base: Screw terminals: Up to 14 AWG Relay type: Form -C Rating: 2 A @ 30 VDC resistive .3 A @ 110 VDC inductive 1.0 A @ 30 VDC inductive B524B1 Isolator base: Dimensions: 6.2 in. (157 mm) x 1.4 in. (36 mm). Maximum: 25 devices between isolator bases. PRODUCT LINE INFORMATION Model FDX -551 FDX -551 R Description Intelligent Thermal Sensor Intelligent Thermal Sensor. with Rate -of -Rise feature. FDX -551A Intelligent Thermal Sensor. ULC Version FDX -551 RA Intelligent Thermal Sensor with Rate of Rise. ULC Version Bases (order separately) Standard U.S. Base. Base, flangeless (European style). Flangeless base (B501) with 24 VDC, 85 dBA internal horn. Relay base. Isolator base. Loop short. Other Accessories XR5 Removal Tool. XP -4 Extension Pole for Removal Tool. RMK400 Recessed mounting kit for 500 series detec- tors (requires B501 base). SMK400 Surface Mounting Kit for 500 series detec- tors. Provides for entry of surface wiring conduit. A B501 base is required. RA400Z* Remote LED. Mounts to single gang box. * Supported by BX -501 and B501 bases only. BX -501 B501 B501 BH B524RB B524BI Isolates SLC Loop against Architectural / Engineering Specifications Specifications are available from Notifier for the AM2020, AFP1010, AFP -200, or System 5000 AIM -200 module on an IBM compatible 3.5" disk in Wordperfect® 5.1 and ASCII for- mats. • NOTIFIER A Pittway Company June 9, 1997 H -160 MMX-1 01 Monitor Module Section: Intelligent/Addressable Devices GENERAL The NOTIFIER MMX -101 (or Canadian MMX -101A) Moni- tor Module provides an interface between the AM2020, AFP1010, AFP -400, AFP -300, AFP -200, or System 5000 (equipped with an AIM -200 module) and normally -open contact alarm initiating devices. Though the MMX -101 can be used to monitor an entire Style B (Class B) initiating circuit, it is ideally suited for monitoring single devices. The MMX -101 is small enough to fit inside a single -gang junc- tion box behind the device being monitored. The small size and light weight allow it to be installed without the need to be rigidly mounted. FEATURES • Built -in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two -wire FACP. No additional power required. • High noise (EMF /RFI) immunity. • Tinned, stripped leads ease of wiring. • Direct dial entry of DECADE address (01 -99). APPLICATIONS • Use to monitor a single device or a zone of 4 -wire smoke detectors, manual fire alarm pull stations, waterflow de- vices, or other normally open dry- contact devices. May also be used to monitor normally open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47 K ohm End -of -Line Resis- tor (provided) terminates the circuit. CONSTRUCTION Controls include two rotary switches for direct dial entry of DECADE address (01 -99). OPERATION Each MMX -101 uses one of 99 available module addresses on an SLC loop. It responds to regular polls from the con- trol panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). S635 BSA 578 -81 -SA CSI18 CS733 (MMX -101A) To Initiating Devices ADDRESS LOOP California State Fire Marshal 7165- 0028:141 7165 - 0028:144 7170 - 0028:153 7170 - 0028:154 7165- 0028:164 0Y0A6.AY, 0V4A5.AY (AFP -200) 0W6A2 (AM2020/AFP1010) MMX -90' (shown actual slze) To UL Listed Control Panel and to next device (SLC Loop) This document is not intended to be used for installation purposes. We try to keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484 -7118 C l OTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Made In the U.S.A. DN -2315 — Page 1 of 2 SPECIFICATIONS Operating voltage: 15 - 28 VDC (peak). Standby current: 230 pA max. plus supervisory current. Temperature range: 32 °F - 120°F (0 °C - 49 °C). Humidity range: 10% - 95 %, relative. Weight: 90 grams (3 ounces). PRODUCT Model MMX -101 MMX -101A SMB -500 LINE INFORMATION Description Monitor Module Monitor Module, ULC Listed Surface Mount Box INSTALLATION The MMX -101 Monitor Module mounts inside a single gang junction box behind the device being monitored. The small size and light weight allow it to be installed without the need to be rigidly mounted. Altemately, the MMX -101 Monitor Module may be mounted in the SMB -500 surface mount box. Mounting hardware and installation instructions are provided with each module. Page 2 of 2 — DN -2315 Minimum wire length 6.0 inches (15 cm) 2.75" (7 cm) 1.30" (3.3 cm) 0.50" (1.26 cm) ARCHITECTURAL/ ENGINEERING SPECIFICATIONS Monitor modules shall be provided to connect one super- vised Initiating Device Circuit (IDC) zone of conventional alarm initiating devices (any N.O. dry- contact device, in- cluding 4 -wire smoke detectors), to one of the Fire Alarm Control Panel Signaling Line Circuit (SLC) Loops. The monitor module shall be small enough to fit inside a single - gang junction box behind the device being monitored or directly into the Fire Alarm Control Panel. The monitor module shall be small enough in size and light enough in weight to allow it to be installed without the need to be rigidly mounted. The IDC zone may be wired for Style B operation. The monitor module shall provide address -set- ting means using rotary decimal switches and shall also store an intemal identifying code which the Fire Alarm Con- trol Panel shall use to identify the type of device. • • NOTIFIER A Pittway Company June 11, 1997 DHX -502 Intelligent Duct Detector Housing Section: Intelligent/Addressable Devices H -121 GENERAL The DHX -502 Series Duct Housing is designed to sample air currents passing through a duct and allows the early detection of developing fire. The DHX -502 Duct Housing will accommodate either the CPX -551 Intelligent Ionization Sensor or the SDX -551 Intelligent Photoelectric Sensor, either of which provides continuous analog monitoring of the unit's sensitivity. When sufficient smoke is sensed, an alarm signal is initiated at the AM2020 control panel, AFP1010 control panel, AFP -200 control panel or AIM -200 module (supports the SDX -551 detector head only) moni- toring the detector, and appropriate action can be taken to shut off fans and blowers, change over air handling sys- tems, etc. This can prevent the rapid distribution or isola- tion of toxic smoke and fire gases throughout the areas served by the duct system. The DHX -502 duct detector system features the superior capabilities of an intelligent sensor in a unit that is easy to install and maintain, making this duct detector the new in- dustry standard. FEATURES • Accommodates intelligent ionization or photoelectric heads. • Continuous sensitivity monitoring and alarm verification from the panel. • Simple change -out of detector heads: twist -in, twist -out. • Easy and quick mounting to round or rectangular ducts. • Outputs for remote test station (separate 24 VDC is re- quired). • Air velocity rating from 500 to 4,000 feet per minute. • UL 268A listed. • Clear polycarbonate cover for convenient visual inspec- tion of sampling tube filters. • Rugged Noryl® housing (mounting portion). • Three -year limited warranty. • Optional remote LED (RA400Z). CONSTRUCTION AND INSTALLATION The twist -in, twist -out detector and base allow the removal of detectors easily and quickly for cleaning and mainte- nance. In addition, detector heads can be changed to fit the application without removing the duct housing. The DHX -502 comes with a built -in exhaust tube. Sampling tubes are available to fit ducts from 1 to 10 feet wide. S1115 CS308 ML154 (DHX -502A) MEA 427 -91 -E ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 0T3A9.AY California State Fire Marshal 3240 - 0028:158 The DHX -502 Intelligent Detector Duct Housing SPECIFICATIONS Dimensions: 14 -1/2" (36.8 cm) wide, 5" (12.7 cm) high, 3-1/2" (8.9 cm) deep. Weight: 2 lbs., 8 oz. (1.1 kg). Operating temperature range: 0 °C to 49 °C (32 °F to 120 °F). Operating humidity range: 10% - 93% relative humidity. Air duct velocity: 500 to 4,000 feet per minute. UL listed to 268A. ELECTRICAL RATINGS Voltage range: 14.5 to 28.0 VDC peak Standby current (nominal): 150 pA at 24 VDC. Power -up surge at max. rated voltage: 1.5 mA -sec. LED current (nominal): 6 mA at 24 VDC. This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more Information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484-7118 C) N OTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 Made In the U.S.A. DN -3530 — Page 1 of 2 Outside Duct Width Inlet Tube Required* Up to 2 feet ST -1.5 2 to 4 feet ST-3 4 to 8 feet ST-5 8 to 10 feet ST-10 INLET TUBE SELECTION *NOTE: Inlet tube is required and must be purchased sepa- rately. Order one inlet tube for each duct detector housing you order. Page 2 of 2 — DN -3530 11111 111111111111111111111111111111111111111111 RA400Z Remote Annunciator LED PRODUCT LINE INFORMATION Model Description DHX -502** Intelligent Duct Housing. NOTE: Intelligent Duct Housing is priced without Inlet Tube or Sensor Head. Order one Inlet Tube and one Sensor Head for use with each Intelligent Duct Housing. CPX -551** Intelligent Ionization Sensor Head. NOTE: The CPX -551 is for use with the AM2020, AFP1010, and AFP200 only. This sensor head, when installed in a DHX -501, is not sup- ported by the AIM -200. SDX -551** Intelligent Photoelectronic Sensor Head. ST -1.5 Metal Sampling Tube, duct widths 1' - 2'. ST -3 Metal Sampling Tube, duct widths 2' - 4'. ST -5 Metal Sampling Tube, duct widths 4' - 8'. ST -10 Metal Sampling Tube, duct widths 8' - 10'. RA400Z Remote LED. F36 -05 -00 Replacement Filters. MO2 -04 Test Magnet. P48 -21 -00 End Cap for Sampling Tube. A2650 -00 Installation Kit (parts bag). RS24 Photoelectronic Replacement Screen. RS14 Ionization Replacement Screen. MOD400R Sensitivity Test Kit. CRT400 Ionization Cover Removal Tool. 156- 473 -00 Applications Manual, Duct Detectors. RTS451 Remote Test Station. * *Order "A" suffix for Canadian (ULC) listed versions. • • NOTIFIER A Pittway Company December 23, 1996 D -122 LCD -80TM Liquid Crystal Display Section: Annunciator Control Systems GENERAL The LCD -80TM (Terminal Mode) is an 80- character, back- lit LCD display annunciator for the NOTIFIER AM2020, AFP1010, AFP -400, and AFP -200 Fire Control Panels. Up to 32 LCD -80TMs may be connected onto the two-wire EIA- 485 Terminal Mode port of each control panel. Each an- nunciator will mimic the fire control panel's display. The LCD -80TM requires no programming, which helps at sys- tem start-up time. FEATURES • 80- character Liquid Crystal Display (20 characters x 4 lines), backlit. • Control switches for System Acknowledge, Signal Si- lence and System Reset. • Time and date display field. • Enable /Disable key switch & phone jack options. • Can be remotely located up to 6,000 feet from the control panel. • Local piezo sounder with alarm/trouble resound. • Flush /Surface /Panel mount option. • Decorative cover plate option. TERMINAL MODE (AM2020, AFP1010, AFP -400, AFP -200, & INA with CCM -1 only) The LCD -80TM mimics the AM2020, AFP1010, AFP -400 and AFP -200 displays. Up to 32 LCD -80TMs can annun- ciate and provide remote reset, acknowledge, and silence of the control panel from remote locations. The AFP1010 and AM2020 display interfaces include a terminal mode driver port for the LCD- 80TMs. A terminal mode port is standard on the AFP -400 and AFP -200 main PC boards. • Displays device type identifiers. • Device and zone custom alpha labels. • Time /date and device address. • May operate in addition to CRT. • NO PROGRAMMING NECESSARY. The LCD -80TM dis- plays time, date, and custom messages received from an AM2020, AFP1010, AFP -400 or AFP -200 system. S635 CS100 MEA 104 -93 -E Vol. 111 California State Fire Marshal 7120 - 0028:156 0 HOLD FOR STATUS CONTRAST ADJUST HOLD FOR LAMP TEST GLOBAL ACKNOWLEDGE SILENCE RESET 0 U 1 LCD -80TM This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484 -7118 N OTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 wolimmomm Made In the U.S.A. DN -5249 — Page 1 of 2 The LCD -80TM AM2020, AFP1010, AFP -200, or AFP -400 PRN Printer RELATED OPTIONS Terminal Mode EIA -485 (2 wires + shield) 24 VDC (2 wires) 6,000 feet maximum wire length between each LCD -80TM LCD -80TM 1 EIA -232 • Up to 32 LCD -80TMs may be used in a continuous Printer Port 4 -wire loop (verify sufficient 24 VDC available). • Each may optionally have ACK/STEP, SIGNAL SILENCE, and SYSTEM RESET switches. • Copies control panel display. • No programming required for LCD- 80TMs. • Small compact design. • Decorative cover plate available. ABF -1D: The ABF -1D is a semi -flush mount backbox for the NOTIFIER LCD -80 Series Annunciator. The ABF -1 D mounts one LCD -80TM. It includes an attractive smoked glass door with NOTIFIER Keylock. Dimensions: Box only: Height = 9- 15/16 ", Width = 4 -5/8" Depth = 2 -12 ". Door: Height = 10.713 ", Width = 6 ", Depth = 0.75 ". O 0 0 0 LCD -80TM 1 Terminal Mode EIA -485 return (2 wires + shield) 0 O 0 CCM -1 Converter Module. Required for terminal mode operation on older AM2020s or AFP1010s that do not include the DIA -2020 or DIA -1010 Display Interfaces. Also required for AM2020 or AFP1010 systems which require a CRT with keyboard. Required for use with INA as well. Uses one ICA-4 chassis slot or two CHS- 4 chassis slots. ADP-4 Annunciator Dress Plate. Allows panel mounting of up to four LCD -80TM modules in a CAB -X3 series cabinet. ABF -1 Annunciator Flush Box, 9- 15/16" high, 4-5/8" wide, and 2 -1/2" deep. Order AKS -1 keyswitch and APJ -1 phone jack if desired. Can also be mounted in ABF -2 orrABF -4 Annunciator backboxes. ABS -1T Deep Surface Backbox (mounts one LCD- 80TM). AKS -1 Keyswitch to enable /disable controls when mounted in ABF or ABS -1T. APJ -1 Annunciator Phone Jack. Mounts to ABF Flush Box or ABS -1T. ABF -1D Flush Annunciator Box with decorative front door (1 module). ABF -2D Flush Annunciator Box with decorative front door (2 modules). DN -5249 — Page 2 of 2 • • 0 01 Flre•uTe® incorPoraTeD FCPS -24F 24 Volt, 6 Amp Remote Power Supply March 20, 1995 GENERAL The FCPS -24F is a compact, cost - effective, 6 amp remote power supply with battery charger. The FCPS may be connected to any 24 volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applica- tions include Notification Appliance (Bell) Circuit ex- pansion (to support ADA requirements) and support of 24 volt system accessory devices. The FCPS -24F provides regulated and filtered 24 VDC power to four notification appliance circuits (two Class B [Style Y] or Class A [Style Z], and two Class B [Style Y] only). Alternately, all outputs may be used in any combina- tion of resettable /non - resettable power outputs. The FCPS -24F also contains a battery charger capable of charging up to 7.0 Amp Hour batteries. FEATURES • Requires input trigger voltage of 24 VDC • FCPS -24F provides two fully isolated trigger inputs • Normally closed trouble contact • Fully supervised power supply, battery, and notifica- tion appliance circuits • Earth fault detection (selectable) • A.C. trouble report immediate, delayed 8 or 16 hours (selectable) • Capable of powering 4 -wire smoke detectors • Output power circuits may be configured as resettable (reset line from FACP required) or non - resettable • Two Class B (Style Y) or Class A (Style Z) notification appliance circuits (circuits 1 & 3) • Two additional circuits that may be individually con- figured as Class B (Style Y) notification appliance circuits (circuits 2 & 4) • Two input/control circuits (from FACP notification appliance circuits or jumper permanently on) • Self contained in lockable cabinet (15 "H x 14.5 "W x 2.75 "D) • Completely power - limited (3.0 amps max/circuit) • 6.0 amp full load output (4.0 amp continuous) • Fully regulated and filtered power output • Integral battery charger • Up to 7.0 AH batteries in FCPS -24F cabinet • Fixed terminal blocks for field wiring capable of accepting up to 12 AWG wire We try to keep our product information up to date and accurate. We can't cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact FiteLite. Phone: (203) 484 -7161 FAX: (203) 484 -7118 e Fireu a Alarms 12 Clintonville Road, Northford, Connecticut 06472 PcorporaTeo Cal fomia State Fire Marshal 7315- 0075:176 MEA 387 -94-E v voovvvvvvvvvvvvvvvvvvvovvvovvvvvvvvvvvv vvvvvvvvvvvvovvvvovvvvovvuvvvvvvovv000v CIOCICICICICIOCICILILICICICIDOOCIOUCIOCIOCIOCICIO0C113130013131,10 "0"0"""000000"""000000000000 vvoov o vvovvvvvvvvvvvvvvvvvvvvvoovvavovvvavvvv ovvvoovvavvovvvvvvvvvvvvoovvvvvvvvvvavvv FCPS -24 PM AVM P11111,01/11.11VIIIIIM 0 00000 00000 000000000000a0000000000000 000 OCICICIDOCICILICICICICICIC100000000CICICICICICILICICIOCICIDOCICILI 0000000000000000000000000000000000000000 o"""" "o"00000000000000 "00000 "0 "0"" "0000 ▪ 00000000000 0000000 ✓ vovov ❑oovoov vvvvvvvvvvvv vvvv voovvv v000v vvvvvvvvv vvvvv SPECIFICATIONS AC Power FCPS -24F: 120 VAC, 50/60 Hz Wire size: minimum #14 AWG with 600V insulation Battery (lead acid only) Nominal Charge Voltage: 27.6V Maximum Charge Current: 250 mA maximum Maximum Battery Capacity: 7.0 AH ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Pace 1 of 3 Page 2 of 3 TH1 • • To Transformer 62 To Transformer p1 Al- )3P1 B fuse 10A 3AG slow blow Tea 11111 R27 CO 1 Terminal Designations 7134 a o . p . H y v v H + + + + + + ... N N t+l cn t.f Of V O 888888888888 rs s r a e m n ra R76 .ao-. R176 R173 R63 . R134 JP2 ■ D31 1133 Tn+ - (Control input tf 1 from FACP) Out +/trouble Contact Out - Trouble Contact hi + (Control Input 62 from FACP) Auxiliary Output ( +24 VDC, 10 mA max) Common ORDERING INFORMATION FCPS -24F Remote charger power supply. Includes main printed circuit board, transformers, surface mount backbox, and installation instructions (120 VAC). PS -1270 Battery, 12 volt, 7.0 AH (two required) A77 -716B 12/24 VDC end-of -line relay for monitoring 4 -wire smoke detector power. NOTIFIER A Subsidiary of Pittway Corporation Jovember 14, 1996 H -130 BGX -101 L Addressable Manual Pull Station Section: Intelligent/Addressable Devices GENERAL The BGX -101 L is an addressable manual pull station with a key -lock reset feature. It provides the AM2020, AFP1010, AFP -400, AFP -200, and System 5000 (equipped with an AIM -200 module) with one addressable alarm initiating in- put. FEATURES • Within ADA 5 Ib. pull force when used without break -tube (models manufactured after 10 -1 -96, identified by an under station spring). • Highly visible. • Easily operated (dual- action). • Attractive shape and textured finish. • Semi -flush, mounts to a standard single -gang (2.125" mini- mum depth), double -gang, or 4" square electrical box. • Operates with or without a crush tube. • Handle latches in down position to clearly indicate the station has been operated. • Key reset. • Screw terminals for easy connection to SLC Loop Channel. • Optional trim ring. • Meets UL 38, Standard for Manually Actuated Signaling Boxes. CONSTRUCTION • Shell, door, and handle are molded of durable LEXAN®(or polycarbonate equivalent) with a textured finish. • 16 gauge steel back plate. OPERATION Pulling the handle down causes it to latch In the down posi- tion. The handle is restored manually by using a mechani- cal key which allows the top of the case to pivot forward and the spring - loaded handle to retum to its normal position. The case can then be pivoted back to its normal position and secured with the key. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow two -digit address setting. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. S692 ADA BGX -101 L BG -TR SB -10 0V4A5.AY (AFP -200) 0W6A2.AY (AM-2020/AF P1010) California State Fire Marshal 7150- 0028:003 93/00141 . 47':RCS - AS , L D 070FIER The BGX -101L Addressable Manual Pull Station PRODUCT LINE INFORMATION Model Description Standard unit. Dual action. Works with, or without, a fiber crush -tube. Includes key locking feature. Optional trim ring. 6 -1/2" High, 5 -1/8" Wide, 5/32" Deep. Surface backbox. This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484 -7181 FAX: (203) 484 -7118 N OTI Fl ER 12 Clintonville Road, Northford, Connecticut 06472 1SO - 9001 Engineering and Manufacturing Quality System Certified to International Standard IS0 -9001 Made In the U.S.A DN -3189 — Page 1 of 2 6011 Sl NSOR2 (736 7 767?), Fax 030 ' ltttp:/ /town.( si sternsensor.( orrt 2112/24ATR Features • Models with built -in sounder* producing NFPA 72 required temporal tone • Models with 135 °F fixed - temperature heat detection • Models with localized, nonlatching smoke alarm and latching thermal • Smart- Check'rm self- diagnostic maintenance feature to satisfy NFPA 72 sensitivity testing requirement • Large, supervised ** plug -in terminal block with captured SEMS screws decreases wiring and installation time • Removable, cleanable insect screen protects sensor from insects and airborne dust • Built -in test switch • Visual alarm, power, and maintenance indicator • 3 -year warranty *patented housing design **patent pending Specifications - 2100D and 2100TD Operating Voltage: 12 or 24 VDC (nominal) Standby Current: 50 pA maximum average Alarm Current: Temperature Range: 2100D: 2100TD: 100 mA maximum limited by panel 32° to 120°F (0° to 50°C) 32° to 100 °F (0° to 39 °C) 2100D Photoelectronic, 2 -Wire 2100TD Photoelectronic with Thermal, 2-Wire 2100TR Photoelectronic with Thermal and Relay, 2 -Wire 2112/24R Photoelectronic with Relax 4-Wire 2112/24TR Photoelectronic with Thermal and Relay, 4 -Wire 2100AT Photoelectronic with Thermal and Sounder, 2-Wire 2112/24ATR Photoelectronic with Sounder, Thermal and Relay, 4-Wire 2112/24AITR Photoelectronic with Sounder, Isolated Thermal and Relay, 4-Wire System Sensor 100 Series low profile, direct - wire detectors pack superb performance and reliability into a small package. Several new models contain a built -in sounder that produces the NFPA 72 required temporal evacuation tone. Advanced circuitry provides superior false alarm immunity, while reducing maintenance. And the Form C relay, standard on most models, allows the detectors to control remote functions such as elevator recall and door closure. The isolated thermal feature on the 2112 /24AITR reduces nuisance alarms and unwarranted calls to the central station. Dimensions Diameter: Height: Shipping Weight: Humidity Range: Models Available 5.5 inches (140 mm) 1.7 inches (43 mm) with bracket 5.3 oz. (150 grams) 10% to 93% RH, noncondensing Specifications - 2100TR Diameter: Height: Weight: Operating Temperature Range: Operating Humidity Range: Latching Alarm: Heat Sensor: System Voltage (VDC): Max. Ripple Voltage: Specifications - 2112/24R and 2112/24TR Diameter: Height: Weight: Operating Temperature Range: 2112/24TR 2112/24R Operating Humidity Range: Latching Alarm: Heat Sensor, 2112/24TR: 5.5 inches (140 mm) 1.7 Inches (43 mm) with bracket 6.8 oz. (192 g) 32° to 100 °F (0° to 38 °C) 10% to 93% Relative Humidity, noncondensing Reset by momentary power interruption 135 °F fixed temperature electronic thermistor 12/24 nom., 8.5 min., 35 max. 30 % of nom. (peak to peak) 5.5 inches (140 mm) 1.7 inches (43 mm) with bracket 6.8 oz. (190 g) 32° to 100°F (0° to 38°C) 32° to 120 °F (0° to 50 °C) 10% to 93% Relative Humidity, noncondensing Reset by momentary power interruption 135°F fixed temperature electronic thermistor Specifications - 2100AT Diameter: Height: Weight: Operating Temperature Range: Operating Humidity Range: Latching Alarm: Audible Signal: Heat Sensor: Specifications - 2112/24ATR and 2112/24AITR Diameter: Height: Weight: Operating Temperature Range: Operating Humidity Range: Latching Alarm: Audible Signal (at 24 VDC): Heat Sensor 2112/24ATR: 2112/24AITR: 5.5 inches (140 mm) 2.05 Inches (52 mm) 7.4 oz. (210 g) 32° to 100°F (0° to 38°C) 10% to 93% Relative Humidity, noncondensing Reset by momentary power interruption 85 dBA minimum when in alann or with supply polarity reversed 135 °F fixed temperature electronic thermistor 5.5 Inches (140 mm) 2.05 inches (52 mm) 7.5 oz. (210 g) 32° to 100 °F (0° to 38 °C) 10% to 93 % Relative Humidity, noncondensing Reset by momentary power interruption 85 dBA typical when in alarm or with supply polarity reversed 135 °F fixed temperature electronic thermistor 135 °F fixed temperature isolated electronic thermistor Standby Current: 50 pA average, 100 pA max. Alarm Current: 25.5 mA min., 100 mA max. (Alarm current must be limited to 100 mA by the control panel. If used, the RA400Z Remote Annunciator operates within the specified detector alarm currents.) Reset Voltage: Reset TIme: Start -up Time: Alarm Initiation and Auxiliary Relay Contact Ratings, Resistive Load: System Voltage (VDC): Max. Ripple Voltage: Standby Current: Alarm Current: System Voltage (VDC): Max. Ripple Voltage: Reset Voltage: Reset Time: Start -up Time: 1.3 VDC min. 0.3 seconds max. 30 seconds max. (after 60 sec. reset) IA 30 VDC 12/24 nom., 10 min., 35 max. 30 % of nominal voltage (peak to peak) 50 pA average 28 mA typical, 35 mA max. at 12V 36 mA typical, 45 mA max. at 24V Reset Voltage: 0.8 VDC min. Reset Time: 0.3 seconds max. Start -up Time: 30 seconds max.(after 60 sec. reset) Alarm Initiation and Auxiliary Relay Contact Ratings, Resistive Load: 1A a 30 VDC EOL Relay: A77 -716B, 12/24 VDC 12/24 nom., 8.5 min., 35 max. 30 % of nom. (peak to peak) Standby Current: 50 pA average, 100 pA max. Alarm Current: 13 mA min., 100 mA max. (if used, the RA400Z Remote Annunciator operates within the specified detector alarm currents.) Reset Voltage: 1.8 VDC min. Reset Time: 0.6 seconds max. Start -up Time: 30 seconds max. (after 60 sec. reset) Reversing Relay: RR1, 12/24 VDC System Voltage (VDC): 12/24 nom., 11.3 min., 35 max. Max. Ripple Voltage: 30% of nom. (peak to peak) Standby Current: 50 pA average, 100 pA max. Alarm Current: 49 mA typical, 60 mA max. at 12V 57 mA typical, 65 mA max. at 24V 0.8 VDC min. 0.6 seconds max. 30 seconds max. (after 60 sec. reset) Alarm Initiation and Auxiliary Relay Contact Ratings, Resistive Load: IA 30 VDC Reversing Relay: RR1, 12/24 VDC EOL Relay: A77 -716B, 12/24 VDC NOTIFIER A Pittway Company August 6, 1998 J -120 Wheelock RS Series Strobes and RSS Series Non - Sync /Sync Strobes Section: AudioNisual Devices GENERAL Wheelock's new RS Strobes and RSS Series Non -Sync/ Sync Strobes offer low current draw and reduced inrush while maintaining their outstanding performance, reliabil- ity, and cost - effectiveness. They meet or exceed the latest requirements of NFPA 72 (National Fire Alarm Code 1996), ANSI 117.1 (National Standard for Accessible and Usable Buildings and Facilities) and UL Standard 1971 (Signaling Devices for the Hearing Impaired). RS /RSS Strobe appliances, when properly specified and installed in accordance with NFPA/ANSI standards, can provide the Equivalent Facilitation allowed under ADA Accessibil- ity Guidelines (ADAAG General Section 2.2) by meeting or exceeding the illumination which results from the ADA's strobe intensity guidelines of 75 candela at 50 feet (15.24 m). This is an illumination of 0.030 lumens per square foot. Wheelock's RS Series Strobes are available with 15 and 15/75 candela intensities for wall - mounting only and non - sync applications. Wheelock's RSS Series Strobes include non -sync and sync functions in one appliance. The SM or DSM Sync Module must be used to achieve synchronization of the strobe. Synchronized strobes can eliminate possible re- strictions on the number of strobes in field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations conceming photosen- sitive epilepsy. The strobe options for the RSS Series are 15, 15/75, 30, 75, and 110 candela intensities for wall mounting; and 15, 30, 75, and 100 candela intensities for ceiling -mount applications. All strobes use a Xenon flashtube enclosed in a rugged LEXAN® lens to provide maximum reliability for effective visual signaling. Wheelock's RS /RSS Series Strobes employ an integral Strobe Mounting Plate (patent pending) that makes it easy to mount to a variety of backboxes. The strobes can be mounted to single -gang, double -gang, 4" (10.16 cm) square, 100 mm European, or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the new NATP (Notification Appliance Trim Plate) may be used. It provides an additional 0.65" (16.51 mm) of trim for the appliance. An attractive cover plate is provided for a clean, finished appearance on all retrofit models. WM3T — Since the inception of UL 1971, strobes cannot be listed for outdoor use. Wheelock offers WM3T strobes for outdoor installations requiring weatherproof appliances and private mode operation where UL 1971 strobes are not required. They are UL 1638 listed at 117 S5391 MEA 151 -92 -E Vol. XIX, XX WM3T CS 356 CS 243 0D7A4.AY Plate California State Fire Marshal 7125- 0785:133 7125- 0785:141 cd and are designed for surface mounting indoors or out- doors. "Not to be used as an Indoor visual evacuation signal or for the hearing Impaired." Only 88 milliamps, 21 - 31 VDC. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. This document is not intended to be used for installation purposes. We try to keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484 -7118 N OTI FI E R 12 Clintonville Road, Northford, Connecticut 06472 ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Made in the U.S.A. DN -5765 — Page 1 of 4 COMMON FEATURES • ADA/NFPA/ANSI compliant. Meets OSHA 29, Part 1910.165. • L9w current. • Strobe mounting plate (patent pending) for single -gang, double -gang, 4" (10.16 cm) square, or 100 mm European backboxes. Wheelock's SHBB shallow backbox Is used for surface mounting. • Low current draw with temperature compensation to reduce power consumption and wiring costs. • Polarized 12 and 24 VDC models with wide listed voltage ranges using filtered DC or unfiltered VRMS input voltage. • Fast installation with In /Out screw terminals using #12 AWG (3.25 mm to #18 AWG (0.75 mm wires. RS Series Features: • 24 volt models only. • Wall- mounting models only. • Available in 15 and 15/75 candela intensities only. • Non -Sync application only. RSS Series Features: • Both non -sync and synchronized function in one appliance. To achieve synchronization, a SM or DSM Sync Module must be used. • Reduced inrush. • 12- or 24 -volt models. • Wall- mounting RSS available in 15, 15/75, 30, 75, and 110 candela intensities. ORDERING INFORMATION Page 2 of 4 - DN -5765 • 15/75 candela, low- current -draw, wall- mounting strobes are listed at 15 candela under UL 1971 and meet 75 candela intensity on -axis for ADA guidelines. • Ceiling- mounting RSS available in 15, 30, 75, and 100 can- dela intensities. GENERAL NOTES • Strobes are designed to flash at 1 flash per second mini- mum from 20 to 31 VDC for 24 VDC models; or 10.5 to 15.6 VDC for 12 VDC models. Note that NFPA -72 (1996) speci- fies a flash rate of 1 to 2 flashes per second and ADA guide- lines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective strobe in- tensity based on UL 1971. • RS /RSS Series strobe products are listed under UL 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C). • The WM3T strobe is listed under UL 1638 for outdoor use with a temperature range of -31 °F to 150 °F ( -35 °C to 66 °C), maximum humidity of 95 %. &WARNING! PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. WALL -MOUNT STROBES Series RS/RSS CEILING -MOUNT STROBES Series RSS 117 cd STROBE Indoor /Outdoor SYNC MODULES'wr** Model Number* RS- 2415W -FR RS- 241575W -FR RSS- 2415W -FR RSS- 241575W -FR RSS- 2430W -FR RSS- 2475W -FR RSS- 24110W -FR RSS- 1215W -FR RSS- 121575W -FR RSS- 2415C -FW RSS- 2430C -FW RSS- 2475C -FW RSS- 24100C -FW WM3T 24 -VFR SM- 12/24 -R DSM - 12/24 -R Input Voltage 24 VDC 24 VDC 24VDC 24 VDC 24 VDC 24 VDC 24 VDC 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 12 VDC / 24 VDC 12 VDC / 24 VDC Strobe Candela 15 15/75 15 15/75 30 75 110 15 1575 15 30 75 100 117 Average Current** (Amps) @: 20 VDC 0.060 0.076 0.060 0.076 0.095 0.157 0.199 10.5 VDC 0.148 0.189 20 VDC 0.078 0.120 0247 0.285 24 VDC 0.050 0.065 0.050 0.065 0.081 0.133 0.161 12 VDC 0.126 0.161 24 VDC 0.067 0.102 0.204 0238 0.088 31 VDC 0.043 0.052 0.043 0.052 0.066 0.108 0.131 15.6 VDC 0.102 0.130 31 VDC 0.055 0.085 0.157 0.190 0.014 (12) / 0.025 (24) 0.020 (12) / 0.038 (24) Mounting Options B, D, E, F, G, H, J, N, 0, R, X B, D, E, F, G, H, J, N, 0, R, X B, D, E, F, G, H, J, N, 0, R, X B, D, E, F, G, H J, N, 0, R, X B, D, E, F, G, H, J, N, 0, R, X B, 0, E, F, G, H, J, N, 0, R, X B, D, E, F, G, H, J, N, 0, R, X B, D, E, F, G, H, J, N, 0, R, X B,D,E,F,G,H,J,N,O,R,X B, D, E, F, G, H, J, N, X B,D,E,F,G,H,J,N,X B, D, E, F, G, H, J, N, X B, D, E, F, G, H, J, N, X J, K NOTE: WM3T -24 -VFR - UL 1638 only. Refer to Wheelock installation instructions #P82037. E, N W NOTES: 1) SUFFIXES USED ABOVE: W = Wall mounting; C = Cei ing mounting; F = Fire lettering; R at end = Red; W at end = White. EXAMPLES: RS- 2415W -FR (Wall mounting - Eire lettering, Eed); RSS- 2415C -FW (Ceiling mounting - Eire lettering; White). 2) SPECIAL PLATE: NATP Trim Plate provides 0.65" (16.51 mm) additional trim for the appliance. Available in red only. * Series RS and RSS wall -mount models are offered in red only. Series RSS ceiling -mount models are offered in white only. Average current per actual Wheelock Production testing @ 10.5, 12, 15.6, 20, 24 and 31 VDC. For rated average and peak current across the UL listed voltage range for both filtered DC and full- wave - rectified (FWR), see the installation instructions (Wheelock #P83500 for wall -mount and #P83501 for ceiling- mount). For descriptions of MOUNTING OPTIONS, refer to NOTIFIER data sheet DN -6111, derived from Wheelock #S7000. SM Sync Modules are rated for 3.0 amperes at 12/24 VDC; DSM Sync Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to installation instructions for SM (Wheelock #P83123) and DSM (Wheelock #P83177). Model Number* Wall Mount Non- Sync Sync w/ SM or DSM Strobe Candela 24 VDC 12 VDC 2 Terminal 4 Terminal NS- 2415W -FR X X X 15 X NS- 2430W -FR X 24 NS- 241575W -FR X X X 15/75 X 7809 X 110 NS- 2430W -FR X X X 30 X NS- 121575W -FR X 12 NS- 2475W -FR X X X 75 X B,D,E,F,G,H,J,O,R,S,X X 7901 NS- 24110W -FR X X X 110 X 30 X NS4 - 2475W -FR NS- 1215W -FR X X X 15 7904 X X B,D,E,F,G,H,J,O,R,S,X NS- 121575W -FR X X X 15/75 NS4- 121575W -FR X X 15/75 NS4- 2415W -FR X X X 15 X Average SYNC MODULE * ** Current SM-12/24-R X NS4- 241575W -FR X X X 15/75 X .025 E,N X NS4- 2430W -FR X X X 30 X 24 .038 X NS4 - 2475W -FR X X X 75 X X NS4- 24110W -FR X X X 110 X X NS4- 1215W -FR X X X 15 X X NS4- 121575W -FR X X X 15/75 X X NH- 12/24 -R ** X X X — X X X Model Number* Order Code Input Voltage Strobe Candela Mounting Options ** NS- 2415W -FR 7805 24 15 B,D,E,F,G,H,J,O,R,S,X NS- 241575W -FR 7806 24 15/75 B,D,E,F,G,H,J,O,R,S,X B,D,E,F,G,H,J,O,R,S,X B,D,E,F,G,H,J,O,R,S,X NS- 2430W -FR 7807 24 30 NS- 2475W -FR 7808 24 75 NS- 24110W -FR 7809 24 110 B,D,E,F,G,H,J,O,R,S,X NS- 1215W -FR 7815 12 15 B,D,E,F,G,H,J,O,R,S,X NS- 121575W -FR 7816 12 15/75 B,D,E,F,G,H,J,O,R,S,X NS4- 2415W -FR 7900 24 15 B,D,E,F,G,H,J,O,R,S,X NS4- 241575W -FR 7901 24 15/75 B,D,E,F,G,H,J,O,R,S,X NS4- 2430W -FR 7902 24 30 B,D,E,F,G,H,J,O,R,S,X NS4 - 2475W -FR 7903 24 75 B,D,E,F,G,H,J,O,R,S,X NS4- 24110W -FR 7904 24 110 B,D,E,F,G,H,J,O,R,S,X NS4- 1215W -FR 7910 12 15 B,D,E,F,G,H,J,O,R,S,X NS4- 121575W -FR 7911 12 15/75 B,D,E,F,G,H,J,O,R,S,X NH- 12/24 -R 7449 12/24 — B,D,E,F,G,H,J,O,R,S,X Average SYNC MODULE * ** Current SM-12/24-R 6369 12 .014 E,N 24 .025 E,N DSM- 12/24 -R 6374 12 .020 W 24 .038 W Average Current (Amperes) @ 24 or 12 VDC Anechoic/ Reverberant dBA levels for Continuous & Temporal (Code 3) Tones Chart Key: Settings Low & High Model Number Low High NS- 2415W -FR .065 .072 NS- 241575W -FR .080 .086 NS- 2430W -FR .087 .097 NS- 2475W -FR .145 .155 NS- 24110W -FR .174 .185 NS- 1215W -FR .133 .137 NS- 121575W -FR .170 .175 Model Number Low Horn /Strobe High Horn /Strobe NS4- 2415W -FR .021/.054 .027/.054 NS4- 241575W -FR .021/.068 .027/.068 NS4- 2430W -FR .021/.081 .027/.081 NS4 - 2475W -FR .021/.133 .027/.133 NS4- 24110W -FR .021/.161 .027/.161 NS4- 1215W -FR .09/.126 .014/.126 NS4- 121575W -FR .09/.162 .014/.162 NH- 12/24 -R (12V).09 (24V).020 (12V).014 (24V).027 Specifications and Ordering Information WALL MOUNT ONLY n ts: * Model # Color is Red, can be ordered in White, Call Customer Service for order code & delivery. Model Code Suffix: W = wall, F = fire lettering or call Customer Service if other lettering is required (Ex. Feugo), R = red, W at end = white, 4 = 4 wire Example: NS-2415W-FR-.41—Red NS4- 2415W -FRt —Red NS- 2475W -FW —White Wall Fire Wall fILFire Fire 4 -tee W ** Refer to Data Sheet S7000 for Mounting Options or page 55 of this catalog. * * * SM Sync Modules are rated for 3.0 amperes at 12 or 24 VDC; DSM Dual Sync Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 and installation instructions (Refer to Fax -On- Demand List located in this catalog). SERIES NS odel # Color is Red, can be ordered in White, Call Customer Service for order code & delivery. ** NH -12/24 can also be ceiling mounted. SEE PAGE 3 FOR GENERAL AND TECHNICAL NOTES. whee bck WHEELOCK AVERAGE CURRENT Average current per actual Wheelock Production Testing at 10.5, 12, 15.6, 20, 24 & 31 VDC. For rated average and peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS, see Table A on page 58 of this catalog or see installation instructions. (Refer to Fax -On- Demand List located in this catalog.) dBA RATINGS FOR SERIES NS/NS4/NH HORN 9 Reverberant dBA Anechoic dBA Volume @ 10 ft. per UL 464 @ 10 ft. Description Setting 12VDC 24VDC 12 VDC 24VDC Continuous Horn High 82 88 89 95 Low 76 82 84 90 Code 3 Horn High 76 82 89 95 Low 70 75 84 90 Specifications and Ordering Information WALL MOUNT ONLY n ts: * Model # Color is Red, can be ordered in White, Call Customer Service for order code & delivery. Model Code Suffix: W = wall, F = fire lettering or call Customer Service if other lettering is required (Ex. Feugo), R = red, W at end = white, 4 = 4 wire Example: NS-2415W-FR-.41—Red NS4- 2415W -FRt —Red NS- 2475W -FW —White Wall Fire Wall fILFire Fire 4 -tee W ** Refer to Data Sheet S7000 for Mounting Options or page 55 of this catalog. * * * SM Sync Modules are rated for 3.0 amperes at 12 or 24 VDC; DSM Dual Sync Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 and installation instructions (Refer to Fax -On- Demand List located in this catalog). SERIES NS odel # Color is Red, can be ordered in White, Call Customer Service for order code & delivery. ** NH -12/24 can also be ceiling mounted. SEE PAGE 3 FOR GENERAL AND TECHNICAL NOTES. whee bck WHEELOCK AVERAGE CURRENT Average current per actual Wheelock Production Testing at 10.5, 12, 15.6, 20, 24 & 31 VDC. For rated average and peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS, see Table A on page 58 of this catalog or see installation instructions. (Refer to Fax -On- Demand List located in this catalog.) dBA RATINGS FOR SERIES NS/NS4/NH HORN 9