Loading...
DEMO-10-908Inspection Number: INSP- 144041 Permit Number: DEMO -5 -10 -908 Scheduled Inspection Date: November 05, 2010 Inspector: Bruhn, Norman Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Dalton Hall Miami Shores, FL 33138 -0000 Project: <NONE> Contractor: EZ CAULKING & WATERPROOFING INC Building Department Comments November 04, 2010 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 For Inspections please call: (305)762 -4949 Permit Type: Demolition Inspection Type: Final Work Classification: Building Phone Number Parcel Number 1121360010160 -17 Phone: (954)427 -9942 Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments Page 4 of 7 BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Roofing Owner's Name (Fee Simple Titleholder) BARRY UNIVERSITY Owner's Address 11300 NE 2 AVE City MIAMI SHORES Tenant/Lessee Name Job Address (where the work is being done) 11300 NE 2 AVE - Dalton Hall City Miami Shores Villa e FOLIO / PARCEL # 11 - 2136 000 - 0050 Is Building Historically Designated YES NO Contractor's Company Name EZ Caulking & Waterproofing, Inc. Contractor's Address 274 Military Trail City Deerfield Beach Qualifier Name Edward Zubik State Certificate or Registration No. CGC 1514643 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 State FL Zi 33161 County Miami -Dade Zip State FL Architect/Engineer's Name (if applicab:.,) 4C4C.- Phone # '9 - 9'2 "T1 cr) Value of Work For this Permit $ Vf Type of Work: ['Addition ['Alteration New ❑ Repair /Replace Describe Work: Dalton Dormers Demolition ct4 Odd oiie( fluat 0 van F per do /iner- /ei'.O'ecl, oQa, Permit No. Master Permit No. C - t 0 0 � CB Phone # Phone # Phone # 561- 756 -0041 Zip 33442 Phone # 561- 756 -0041 BY: Square / Linear Footage Of Work: % 9 - Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ OS F. E�G�III�I3 MAY 2 n zoo U Certificate of Competency No. 11 I See Reverse side -4 Demolition ter: * * ** * * * **** *** ** * * * * * *** **** * **** *Fees * ** * *****,t,v******** * *** *** * * ** ** *,r * *** ** Submittal Fee 4111 Permit Fee $ yQ CCF $ CO /CC TRW ►, Notary $ raining/Education Fee $ 1 • Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approv- % a s a reinspection fee will be charged. Signature Owner or Agent ,, pit Contractor The foregoing instrument was acknowledged before me this I - 1 The foregoing instrument was acknowledged before me this I 3— day of a9Vy , 20 l0 , by g1V& Q-- k7) �Y�`'�f , day of I.4 , 2010 , by d G t who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: APPLICATION APPROVED BY: (Revised 07/10/07) ; w R Notary Public State of Florida tz Jeffry J Yao My Commission DD613542 Ex ires 11/12/9010 p0Wl / ,, i JAVIER MARTINEZ . i Notary Public - State of Ftorida Comm. Expires Jun 10, 2013 Commission • DD 898148 NOTARY Sign: Print: My Com ssion Expires: r who has produced My Commission Expires: 11 71- i6 10 Plans Examiner Engineer Zoning lT Strip and Removal Glove Bag Bulldozer Wrecking Ball 1 Wet Method • Dry Method Explode Bum Down OTHER: MUST OBTAIN PRIOR DERM APPRnval aFr nvc 1 rarer- A MEW . - n 1,.., Florida Department of Environmental Protecti Division of Air Resource Mana NOTICE QF ASBESTOS RENOVATION OTICE (CHECK ONE ONLY): Ilif ORIGINAL ❑REVISED� Q CANCELLATION TYPE OF PROJECT (CHECK ONE ONLY):0 DEMOLITION 0 RENOVATION C°J ROOFING IF DEMOLITION, WAS IT AN ORDERED DEMOLITION? 0 YES 0 NO IF RENOVATION: File Quality 1.____, A f IS IT AN EMERGENCY RENOVATION OPERATION? 0 YES 0 NO anagE'1T7 @fyt ®i!laSS IS IT A PLANNED RENOVATION OPERATION? 0 YES 0 NO Process # �: II. IV. V. VI. - FLORTDA TYPE OF N Facility Name • &J Y Uri/vers—i — Prior Use: City /' Gm + sShafe j Address / /300 Ale 02fieZ 41/eo4ue. Cit l a/ilf` (Shate 5 Site Building Size I668 (Square Feet) School/Col leg �C1 niversity Present Use School/Coll Facility Owner /f //G/ if / ?/4/ Address /Z3 /l/� 2'u five State FL Zip 33/‘ / Contractor's Name / / h Q c rhee Address e r' /5o ��ti /074 ' e,i�e • ove /w Cit 'r1J /gyp Qeaci State �L Florida Licence No. C,GC• 05 4 4 67" Scheduled Dates: Asbestos Removal ( mm/dd/yy) Start p rocedures to be Used (Check All That Apply): Procedures for Unexpected RACM: 11/16 VII. Asbestos Waste Transporter: Name \S S Address 990 /%//64:1 °live Cit L44174A/4 99 VIII. Waste Disposal Site: Name cs-Gvs Address b //U&`2 4 City 6e1 IX. Amount of RACM or• ACM square feet surfacing material linear feet pipe cubic feet of RACM off facility components square feet cementitious material square feet resilient flooring 90(/ square feet asphalt roofing 07/re i epaiks). DERM USE 0 LY Postmark/Date Received State y r, DeLiL r)iti i9-LL. State FL- Zip 23/6/ County Consultant Inspecting Site Age in Years # of Floors 2, Residence Small Business . Other Residence Small Business Other zip 33069 State Zip 339 a D4oO Ai /A' Phone ( 3 0 5 ) 9 - 3 / 55 Phone(9 1/7— - /07 - Is the contractor � exemptt from Iicensure under section 469.004(7), F.S.? 0 YES (F<10 Finish: /3g Der4 z�ReRBV rr( mm/dd/yy) Start: 4 ep Phone ( 7 ) / 6 12 8' / 3 1 ) ?- 3 2- Class zip 33 6 Z MIAMI -DADE D, E, R. AIR QUALITY 'MANAGEMENTtroVl` ILi This is to certify that the real.r :-d Notification(s) Regarding asbestc:; 1 e been submitted in Compliance with pplicable regulatio s. C! ., ate Signed I certify that the above information is correct and that an individual trained in the provisions of this regulation (40CFR Part 61, Subpart M) will be on -site during the demolition or renovation and evidence that the required training has been accomplished by this person will be available for inspection during normal business hours. j � ij4 , 44e2 Name of Owner / V I - . `; 1,,, ., f% " OJ ®2 , 11 — 91 — � '/o 7 (Signature o 0 er /Operat. (Date) (Contact Phone #) ID# Dept. of Environmental Resources Mgmt. Air Section 2nd Avenue, Suite 9-223 33130-7540 UMW MAY 2 4 zoo Finish: Ai ' PERMIT # :DE n --C PF. DATE: 1 2, (2-r-S Contractor ❑ Owner ❑ Architect Picked up 2 sets of plans and (other) S -0-' Address: 1 t a4 NiC 2 A■ra. From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to contin permitting process. Acknowledged by: PERMIT CLERK INITIAL: RESUBMITTED DATE: PERMIT CLERK INITIAL: RECEIPT M iami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 r MIAMFDiADE COUNTY BUILDING CODE COMPLIANCE OFFIKE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE Active Ventilation Products 311 First Street Newburg, NY 125504857 SCOPE: ''.' /!TH ALL FEDERAL MIAMI -DADE COUNTY, FLORIDA — TR ADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 �� MIAMI FLORIDA 33130 -1563 -2901 FAX (305) 375 -2908 This NOA is being issued under the applic bie rides and regulations lhe use a construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Aura - D Ventilator LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA#04- 0622.03 and consists of pages 1 through 3. The submitted documentation was reviewed by Alex Tigera. NOA No.: 09- 0806.08 Expiration Date: 08/05/14 Approval Date: 09/23/09 Page 1 of 3 ROOFING COMPONENT APPROVAL Category: Roofmg Sub - Category: 07720 Ventilation Type: Static Roof Vent Materials Aluminum Deck Wood TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Aura -D (AV -24) Vent Vent : 28" dia. x 10" high TAS 100(A) Factory assembled 24" Deck Flange: 30" x 30" x 6 -'/4" opening aluminum static All parts 0.40" thick ventilation system. MANUFACTURING LOCATION: 1. Newburgh, NY EVIDENCE SUBMITTED Test Agency Test Identifier Description Date PRI Asphalt Technologies, Inc. AVP -005 -02 -01 TAS 100 09/24/03 APPROVED ASSEMBLY: System Type A: Mechanical attachment of static vent over composite shingles. Cutout: Installation: Starting with a shingle course down roof edge closest to horizontal centerline of the 24" cutout, roll all shingles in the area carefully upward, and completely remove all shingle nails that are exposed and within the area enclosed by the flange. Apply 3 4" continuous bead of approved roofing cement around the outside perimeter of the opening and two / beads of roofing cement beneath the vent flange at 1" and 2" respectively from the perimeter of vent flange, carefully slide upper half of flashing up roof beneath shingles previously rolled back, until base is centered over 24" cutout. Secure the base unit to roof using 11 ga. ring shank nails 1" from the edge at all four corners. Next place nails at approximately 7" o.c. from the corners and 1" from the outside edge of the flange. Use a minimum of (16) sixteen nails (See Fastening Pattern below). Nails shall be of sufficient length to penetrate through roof sheathing a minimum of 3 /16 ". Apply approved roofing cement to underside of shingles overlapping flashing, and press them down onto the flashing. Seal all nails and shingles edges with an approved roofing cement. Net Free Area: Refer to manufacturers published literature. At chosen location and centered between two roof rafters and aligned a minimum of 18" from the ridge, cut a 24" diameter hole through shingles and sheathing boards. NOA No.: 09- 0806.08 Expiration Date: 08/05/14 Approval Date: 09/23/09 Page 2 of 3 A LIMITATIONS: 1. Refer to applicable Building Codes for required ventilation. 2. Aura -D (AV -24) Vent shall comply with applicable Building Code. 3. This acceptance is for installations over asphaltic shingle or low slope roofing. 4. Aura -D (AV -24) Vent Vent shall not be installed on roof mean heights greater than 33 feet. 5. Aura -D (AV -24) Vent shall comply with 1517.6 of the Florida Building Code (FBC). 6. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. DETAIL Aura D Vent END OF THIS ACCEPTANCE NOA No.: 09- 0806.08 Expiration Date: 08/05/14 Approval Date: 09/23/09 Page 3 of 3 . • •••• • •••• • • • • • • • • Atlantic & Caribbean Roof Consulting, LLC TESTING & ENGINEERING SERVICES DADE TEST LABORATORY 08- 0709.13 FL. CERT. OF AUTH. #9036 DORMER REMOVAL EVALUATION DALTON HOUSE / DUNSPAUGH HOUSE BARRY UNIVERSITY 11300 N.E. 2 AVENUE MIAMI SHORES, FLORIDA Infinity Roofing Company, Inc. May 18, 2010 1839 NW 29 Street • Oakland Park, Florida 33311 • (954) 742 -9515 Phone • (954) 742 -9513 Fax E -mail: esmause @roofconsultant.net • dflood @roofconsultant.net AC RC Infinity Roofing Inc. 1150 SW 10 Avenue Suite 201W Pompano Beach, Fl. 33069 Attn: Javier Martinez Re: Permit # RF -12 -09 -2064 Existing Dormer Elimination Barry University Dunspaugh & Dalton Halls 11300 NE 2 Avenue Miami Shores, Fl. Atlantic & Caribbean Roof Consulting, LLC TESTING & ENGINEERING SERVICES DADE TEST LABORATORY 08 -0709.13 FL. CERT. OF ADM. #9036 May 18, 2010 ACRC #10 -0017 ACRC This report is in reference to the existing dormer elimination for the 4/12 sloped tile roof area over the above referenced Dalton - Dunspaugh House located at Barry University in Miami Shores, Florida. The dormers consist of wood framing attached onto the existing r aflei .with a tile facing. The existing supports are configured in a kingpost type truss construction, with no diagonals. This „.tattlts in basic►alfy a series pt rafters vertically supported and spaced at 16" on center. The eave height is @ 20 feet and the dormers • are •situat .d moximaaely' halfway up the roof slope at 26 feet. Due to continuing leaks, these dormers are to be removed and • ntr)faced with 1 Vx 8" planked wood decking and subsequently sealed with a #30 felt and a layer of TU Plus self - adhering •' underlayment. Flat, coaoreioe •t 1es will finally be adhered over the underlayment using PolyPro AH 160 adhesive foam. •••. • •• •• • • • • 6Ai�'RC reptCs'ettatives V1tit. the site Monday, May 17, 2010 to view the dormer and deck attachments from underneath the roof. • tfig ACRC tisu t1 asseeSifieiit confirmed the 16" wood support spacings and the attachments of the decking that was used to replace • • • tl dormers. The dormerr V'ad been initially attached onto the supporting rafters with no type of spacing other than the 16' o.c. • • • w port ii ite ; Thest 4¶ft&i•supports span from the eave to the peak of the gable roof, extending through the existing dormers that • • were con ctid separafeT}r A$d supported by the rafters. • • •• •••• • • The existlgg i1grmers c a n of ctively be eliminated by insertion of additional 1"x 8" wood plank decking that matches the existing remaining deck. Attachment to the trusses must be done using three (3) - 8d common or ring shank nails at each truss support as per Table 2324.1 of the 2007 Florida Building Code. From a structural standpoint, based upon our observations, it is our opinion that the existing dormers can be replaced with matching wood plank decking without any additional stress on the wood framing. The existing dormers currently provide ventilation to the plenum area of the Dalton - Dunspaugh House roofs. Ventilation to these roofs must be maintained to comply with directives set forth by the Florida Building Codes. Therefore, a series of aluminum static roof vents are to be installed on the dormer locations to maintain adequate ventilation. The proposed vents are Aura -D (AV -24) Ventilators, manufactured by "Active Ventilation Products ", located in Newburg, N.Y. These roof vents will be installed as per Miami -Dade N.O.A. #09- 0806.08, and are approved by Miami -Dade County. The Aura -D Vent is also in compliance with Paragraph 1517.6 of the 2007 Florida Building Code. ACRC will continue to provide consulting services upon request. If further assistance is required, or questions arise concerning this report, please do not hesitate to contact this office. Donald J. Flood, P.E. Florida Registration #44847 @ou.AWL q'L---k 8 cc: file Attachments: 1) Photographs, 1 1839 NW 29 Street • Oakland Park, Florida 33311 • (954) 742 -9515 Phone • (954) 742 -9513 Fax E -mail: esmause @roofconsultant.net • dflood @roofconsultant.net • • • Infinity Roofing Inc. 1150 SW 10 Avenue Suite 201W Pompano Beach, Fl. 33069 Attn: Javier Martinez Re: Permit # RF -12 -09 -2064 Existing Dormer Elimination Barry University Dunspaugh & Dalton Halls 11300 NE 2nd Avenue Miami Shores, Fl. • • • • • • • .. • • ...• • • • • •. • • • • • . • • •• • • • • • • ••. • •••• • • • •• • • • • • • • ••.. .. •• • • • • •••• •••. • • .••. • • .• • • • • • Atlantic & Caribbean Roof Consulting, LLC TESTING & ENGINEERING SERVICES DADE TEST LABORATORY 08- 0709.13 FL. CERT. OF AUTH. #9036 DALTON - DUNSPAUGH HOUSE 2 1839 NW 29 Street • Oakland Park, Florida 33311 • (954) 742 -9515 Phone • (954) 742 -9513 Fax E -mail: esmause @roofconsultant.net • dflood@roofconsultant.net AC RC May 18, 2010 ACRC #10 -0017 • • • • • • Infinity Roofing Inc. 1150 SW 10` Avenue Suite 201W Pompano Beach, Fl. 33069 Attn: Javier Martinez Re: Permit # RF -12 -09 -2064 Existing Dormer Elimination Barry University Dunspaugh & Dalton Halls 11300 NE 2nd Avenue Miami Shores, Fl. •••• • • • • •••• • • • • • • • • • • • • • • • • • • Atlantic & Caribbean Roof Consulting, LLC TESTING & ENGINEERING SERVICES DADE TEST LABORATORY 08- 0709.13 FL. CERT. OF AUTH. #9036 EXISTING DORMER: EXTERIOR VIEW 3 1839 NW 29 Street • Oakland Park, Florida 33311 • (954) 742 -9515 Phone • (954) 742 -9513 Fax E -mail: esmause @roofconsultant.net • dflood@roofconsultant.net ACRC May 18, 2010 ACRC #10 -0017 Infinity Roofing Inc. 1150 SW 10 Avenue Suite 201W Pompano Beach, Fl. 33069 Attn: Javier Martinez Re: Permit # RF -12 -09 -2064 Existing Dormer Elimination Barry University Dunspaugh & Dalton Halls 11300 NE 2nd Avenue Miami Shores, Fl. • • • Atlantic & Caribbean Roof Consulting, LLC TESTING & ENGINEERING SERVICES DADE TEST LABORATORY 08- 0709.13 FL. CERT. OF AUTH. #9036 EXISTING DORMER CONSTRUCTION OVER RAFTERS 4 1839 NW 29 Street • Oakland Park, Florida 33311 • (954) 742 -9515 Phone • (954) 742 -9513 Fax E -mail: esmause @roofconsultant.net • dflood @roofconsultant.net AC RC May 18, 2010 ACRC #10 -0017 • • s e • • • • Infinity Roofing Inc. 1150 SW 10 Avenue Suite 201W Pompano Beach, Fl. 33069 Attn: Javier Martinez Re: Permit # RF -12 -09 -2064 Existing Dormer Elimination Barry University Dunspaugh & Dalton Halls 11300 NE 2 " Avenue Miami Shores, Fl. 4 • Atlantic & Caribbean Roof Consulting, LLC TESTING & ENGINEERING SERVICES DADE TEST LABORATORY 08- 0709.13 FL. CERT. OF AUTH. #9036 AC RC May 18, 2010 ACRC #10 -0017 EXISTING DORMER CONSTRUCTION: SUPPORTS & WOOD PLANK DECKING 5 1839 NW 29 Street • Oakland Park, Florida 33311 • (954) 742 -9515 Phone • (954) 742 -9513 Fax E -mail: esmause @roofconsultant.net • dflood cr,roofconsultant.net • • • • • • • • • Infinity Roofing Inc. 1150 SW l0` Avenue Suite 201W Pompano Beach, Fl. 33069 Attn: Javier Martinez Re: Permit # RF -12 -09 -2064 Existing Dormer Elimination Barry University Dunspaugh & Dalton Halls 11300 NE 2 " Avenue Miami Shores, Fl. Atlantic & Caribbean Roof Consulting, LLC TESTING & ENGINEERING SERVICES DADE TEST LABORATORY 08- 0709.13 FL. CERT. OF AUTH. #9036 AC RC May 18, 2010 ACRC #10 -0017 VIEW OF INTERIOR ROOF SUPPORT CONSTRUCTION 6 1839 NW 29 Street • Oakland Park, Florida 33311 • (954) 742 -9515 Phone • (954) 742 -9513 Fax E -mail: esmause(aroofconsultant.net • dflood @roofconsultant.net