Loading...
RF-06-23-1455Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Permit NO.: RF-06-23-1456 Permit Type: Roof Work Classification: Tile' Permit Status: Approved Issue Date:06/12/2023 Expiration: 12/12/2023 Parcel Number 1245 NE 96TH ST, Miami Shores, FL 33138 1132060143780 Contacts CURTIS BRODSKY Owner 1245 NE 96 ST, MIAMI SHORES, FL 33138 crbrodsky@aol.com OBENOUR ROOFING SHEET METAL & Contractor SUPPLY CO. INC JAMES OBENOUR 9822 NE 2 AVE SUITE 9, MIAMI SHORES, FL 33138 Business: 3057572612 OBENOURROOFING@AOL.COM Mobile: 3054696896 Sandy Hart 9822 ne 6avenue 9, Miami shores, FL 33138 Business: 3057572612 harttwohart5@aol.com Mobile: 9548022965 Home: 3057577861 Other: 3053311200 Description: REROOF 1&2 STORY ROOFS WITH GRANADA 2 Valuation: $ 122,000.00 PIECE HANDMADE CLAY BARREL TILE ADHESIVE SET - COLOR: CLAY Total Sq Feet: 3,531.00 Fees Amount Application Fee - Other $50.00 CCF $73.20 DBPR Fee $10.06 DCA Fee $6.71 Education Surcharge $36.60 Permit Fee (Manual) $620.89 Planning and Zoning Review Fee $70.00 Scanning Fee (Manual) $12.00 Technology Fee (Manual) $67.09 Total: $946.55 Inspection Requests: -05-762-4949 11' Payments Date Paid Amt Paid Total Fees $946.55 Check # 11873 06/12/2023 $896.55 Check # 11865 06/07/2023 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Signature: Owner tt�N[5 o !/he nex,, ✓ , / Applicant / Contractor / Agent 1a a 3 Date June 12, 2023 Page 2 of 2 RECE�TV�D Miami Shores Village JUN 0 7 2023 Building Department BY: !3� 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 2020 ' -14h BUILDING Master Permit No. f�>F"a40'23'ly$s" PERMIT APPLICATION sub Permit No. BUILDING ❑ ELECTRIC dROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL F-IPLUMBING ❑ MECHANICAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP � CONTRACTOR. DRAWINGS JOB ADDRESS: � L5 11 'InLO�1t.TO City: Miami Shores County: Miami Dade Zip: �3138 Folio/Parcel#: Ej"-O(,-0Ir{-3760 Is the Building Historically Designated:Yes NO ✓ Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: Tenant/Lessee Name Email: CONTF Acicim Email: Qualifi State Certification or Registration #: 6T-05 -2 4;- Certificate of Competency #: _ DESIGNER: Architect/Engineer: Phone#: 5!%S %d l a.G f 1— Address: / City: State: _Zip: Value of Work for this Permit: $ /.2 ?� o-b rl Square/Linear Footage of Work: -3'.531 Type of Work: ❑ Addition [1, Alteratpn ❑ New Repair/Replya ee - ❑ Demolition Description of Work: DO ul — ( t =11111C.81 ' /..§ Specify color of ccolor thru tile. G (AY Submittal Fee $ r� • � Permit Fee $ • e� CCF $ 73• w CO/CC $ Scanning Fee $ 12• 1�0 DCA Fee $ (O• Z ( DBPR $ LO. CX0 Notary $ Technology Fee $ &-7. o `1 Training/Education Fee $ .3 to 40 Double Fee $ Structural Reviews $ P&Z Review $ Bond $. TOTAL FEE NOW DUE $ F%1'h, riS (RevisedD4/05/2022) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or Installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with on estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature " -k & OWNER or AGENT The foregoing instrument was acknowledged before me this day of 20cA 3 . by i r who is personally known to me or who has produced r ( as identification and who did take an oath. NOTARY PUBLIC: Signat4�U`�"'c'Q CONTRACTOR The foregoing Instrumerlit was acknowledged before me this O C- day of ^ ( 20 � by ,,r Me5—bt/✓E�61�(1 who is_personallyknownto me or who has produced as identification and who did take an oath. NOTARY PUBLIC: r (Revised04/05/2022) Structural Review Clerk S GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECMON SERVICES DRn,INGSSRVICES - 0DEc DYNATECH ENGINEERING CORP. ,/ _ W .DYNATECHENGINEERING.COM ROOF TILE UPLIFT CAPACITY IN ACCORDANCE WITH 2020 FLORIDA BUILDING CODE, 7TH EDITION, TEST PROTOCOL TAS•106 STANDARD PROCEDURE FOR FIELD VERIFICATION OF THE BONDING OF MORTAR OR ADHESIVE SET TILE SYSTEMS AN MECHANICALLY ATTACHED, RIGID, DISCONTINUOUS ROOF SYSTEM DATE: JUNE 28, 2023 1 PERMIT#: RF-06-23-1455 CLIENT: OBENOUR ROOFING: 9822 NE 2nd Avenue, #9, Miami Shores, FL 33138 v ROOF AT FOR REPAIRED AREA ONLY: 340 NE 94TH STREET MIAMI SHORES, FL 33138 Testing Equipment: Humboldt Scale Model H-4620. The test results presented here reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof condition are continuously changing due to the exposure to the element and rooftop traffic. Client recognizes that actual conditions in areas not tested by Dynatech Engineering Corp (DEC) may differ from those anticipated in DEC's report. -Client understands and acceptsthatthis can significantly increase the cost of construction for its future projects. Client agrees that DEC shall not be responsible or liable for any variations in the actual conditions of areas not tested by DEC. NUMBER OF TESTS TEST LOCATIONS: SEE SKETCH FIELD UPLIFT PULL TEST TEST RESULTS 5 (F) FIELD > 35 LBS PASSED 2 (P) PERIMETERS > 35 LBS PASSED TILE TYPE/ATTACHMENT: Flat roof tile polyfoam set. INSPECTED BY: JM ROOF SKETCH Sincerely yours, �� i.!/rssDsvt Wissam Naamani, P.E. DYNATECH ENGINEERING CORP Florida Reg. No. 39584 Special Inspector No. 757 L it Page 1 of 1 9SO WEST 84TH STREET. HUaLEAH. FL 33014 PHONE (305)OW-0499 FAx(305)SM-9598E-n1FO0DMAMCHE4GINEERINGEOMAlrF r t Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.ciov AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 181 t 2 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: C *1s Property Address: I ('qs Li L S;t Roofing Permit Number: kr-vlp- 23- 1 5 6- Z' Dto-23 Dear Building Official: I oT C (ff J'P- certify that I have improved the roof to wall connections of the referenced property as required by the Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Residential Structures as adopted by the Florida Building Commission by Rule 9B-3.047 F.A.C. signature Print Name State of Florida Miami Dade County The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this 11 day of 20 2J� Notary Public, State of Fll ida at Large Seal "��—DUFFIN CATHERINE A. '0MMISSI08 �(pIRES:M #14HZ522 p25., _undervmu For Forms and Applications click here: http://bidg. mia mishoresvi llage.com/W ebLi n k/Browse.aspx?id=118080&d bid=0&repo=Mia miShoresVillage RevO1 142021 Affidavit of Compliance with roof to wall Page 1 of 1 Permit # W- ur Z3- Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.gov DATE: INSPECTION AFFIDAVIT i hi licensed as a(n) Co tror / Engineer / Architect, (Orint name and circle License Type) License #: C o, A �40'1 On or a & time) work I did personally inspect the roof deck nailing (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) State of Florida, Miami Dade County: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this day Notary Public, State of Florida at Large CATHERINE A, DUFFIN MY COMMISSION # HH 089522 EXPIRES: May 14, 2025 bonded TMu Notary Public Underwriters For Forms and Applications click here: http://bldg.miamishoresvillage.com/WebLin k/Browse.aspx?id=118080&d bid=0&repo=M is miShoresVillage Rev01142021 Inspection Affidavit Page 1 of 1 G£OT£C,,,,, L I£NVIRONM£NTAL I I TERJALS TESTING I ASBESTOS I ROOFTEbTING I INSMCMON SERVICES I DRILLING SERVICES DYNATECH ENGINEERING CORP. WW W.DYNATECHENGINEERING.COM ROOF TILE UPLIFT CAPACITY IN ACCORDANCE WITH 2020 FLORIDA BUILDING CODE, 7TH EDITION, TEST PROTOCOL TAS-106 STANDARD PROCEDURE FOR FIELD VERIFICATION OF THE BONDING OF MORTAR OR ADHESIVE SET TILE SYSTEMS AND MECHANICALLY ATTACHED, RIGID, DISCONTINUOUS ROOF SYSTEM DATE: AUGUST 22, 2023 PERMIT#: RF-06-23-1455 CLIENT: OBENOUR ROOFING: 9822 NE 2ND AVENUE MIAMI SHORES, FL 33138 ROOF AT (ONE STORY PORTION ONLY): 1245 NE 96TH STREET MIAMI SHORES, FL 33138 Testing Equipment: Humboldt Scale Model H-4620. The test results presented here reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof condition are continuously changing due to the exposure to the element and rooftop traffic. Client recognizes that actual conditions in areas not tested by Dynatech Engineering Corp (DEC) may differ from those anticipated in DEC's report. Client understands and accepts that this can significantly Increase the cost of construction for its future projects. Client agrees that DEC shall not be responsible or liable for any variations in the actual conditions of areas not tested by DEC. NUMBER OF TESTS TEST LOCATIONS: SEESKETCH FIELD UPLIFT PULLTEST TEST RESULTS 39 (F) FIELD > 35 LBS PASSED 40 (P) PERIMETERS > 35 LEIS PASSED 39 (F) FIELD > 35 LBS PASSED 14 (R) RIDGE AND HIP CAPS > 35 LBS PASSED TILETYPE/ATTACHMENT: Barrelrooftilepolyfoamset._ - - ---INSPECTEDBY:IM ROOF SKETCH 14' 19, C P P P P P P P C I, 7' 8' P F F F P F F F 16' C P P P P C 24 P F F P F F P F F F 24' P P F F F F P 12' P F F 19, P F F P P P F F P P F F F FT<F F l< F P C P P P P P P P P P P F F P 14' 12' 18, P F F P F 6 8 F C 4, 8' Sincerely yours, I Z3 •Z _ * No. 39584 Wissam Naamani; P. _ 3 DYNATECH ENGINEERING CORP. o ; srArE OF Florida Reg. No. 39584 -%�r •f,..... • Special Inspector No. 757 `' S�ONA... V e%" Page 1 of I 7 OV Tr 84TH 5TREET.HIAI.EAH. M33014 MOM(305) 828-9499 FAX(305) 826-GS9813 A-WFOOEFMAMCHENGINEERING.COM GEOTECNNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASEESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES c DYNATECH ENGINEERING CORP. / W W W.DYNATECHENGINEERING.COM ROOF TILE UPLIFT CAPACITY IN ACCORDANCE WITH 2020 FLORIDA BUILDING CODE, 7TH EDITION, TEST PROTOCOL TAS-106 STANDARD PROCEDURE FOR FIELD VERIFICATION OF THE BONDING OF MORTAR OR ADHESIVE SET TILE SYSTEMS AND MECHANICALLY ATTACHED, RIGID, DISCONTINUOUS ROOF SYSTEM DATE: OCTOBER 18, 2023 1 PERMIT#: RF-06-23-1455 41 • CLIENT: OBENOUR ROOFING: 9822 NE 2NO AVENUE MIAMI SHORES, FL 33138 ROOF AT: 1245 NE 96TH STREET MIAMI SHORES, FL 33138 Testing Equipment: Humboldt Scale Model H-4620. The test results presented here reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof condition are continuously changing due to the exposure to the element and roof top traffic. Client recognizes that actual conditions in areas not tested by Dynatech Engineering Corp (DEC) may differfrom those anticipated in DEC's report. Client understands and accepts that this can significantly increase the cost of construction for its future projects. Client agrees that DEC shall not be responsible or liable for any variations in the actual conditions of areas not tested by DEC. NUMBER OF TESTS TEST LOCATIONS: SEE SKETCH FIELD UPLIFT PULL TEST TEST RESULTS 10 (C) CORNERS > 35 LBS PASSED 49 (P) PERIMETERS > 35 LBS PASSED 65 (F) FIELD > 35 LBS PASSED 31 (R) RIDGE AND HIP CAPS > 35 LBS PASSED TILE TYPE/ATTACHMENT: Barrel roof tile polyfoam set. INSPECTED BY: JM ROOF SKETCH C g• 10' P P F F P F 16, P F F F.' F C P P P P P •. F F,•• P F F F F pp F{t F� l3' F F '. F F' F F P F F F F F F C F P F P P F F P M, I8' P F F P F F F P 3' P F F F F 25' P F F F p F 7. P P F F F P 3'. P P P 4 P F 4- F P F F p 16' Sincerely yours, , ; °SAAD yq''-, S5 ,L/�.,, 'C a? .. �\C ENSf'gTq Wissam Naamani, P.E. No. 39584 ' DYNATECH ENGINEERING CORP. qp:. suTE or Florida Reg. No. 39584 =;o '••�CORtov, Special Inspector No. 757 °,SS/ONAI-�` F P F FF P19, F F F F P Page 1 of 1 750 WEST 847rH STREET, HMLEAH, FL 33014 PHONE (305) e2a-7499 FAx (30s) eas-95sa EMAIL:INFOODYNAMCHENGINEEREJG.COM EC J?Y�GFav E'�!D JUN 0 7 2023 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES BY: P11011— SECTION 1525 HIGH -VELOCITY HURRICANE ZONES —UNIFORM PERMIT APPLICATION Florida Building Code 7th Edition (2020) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 172,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,I ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2, From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation CITY COPY Miami Shores (01 Vi la uilding Department Zoning Dept. ( Date 1 3 Building Dept. Date Subject to compliance l all Fe a al, State and Qounty rules Z3rSns. Permit# F-06 - FLORIDA ROOF ASSEMBLIES AND ROOFTOP STRUCTURES yJ JU,N b 7 202J Florida Building Code7th Edition (2020) BY: High -Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) Master Permit No. Contractor's Name '2D�'o��F/�!' Process No. Job Address %,tfr A1,C 9'G fr.pr/Mro' *64 S ROOF CATEGORY / ar Mortar/Adhesive Set Tiles ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF TYPE ❑ New roof ❑ Repair ❑ Maintenance 2--"Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) — Steep Sloped Roof Area (SF) 3S9/ Total (SF) 315-51 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, root crams, scuppers, ovemow suu i1U15 GI U UVtl111UW UIUIIIJ. II IUUVG VII11011- sions of sections and levels, clearly identify dimensions of elevated pressure zones en location of parapets. . /Sro2y N 474 5 FLORIDA BUILDING CODE — BUILDING, 7th EDITION (2020) ROOF ASSEMBLIES AND ROOFTOP STRUCTURES ' Florida Building Code7th Edition (2020) High -Velocity Hurricane Zone Uniform Permit Application Form Ci.i/o�Y) Sectlon D (Steep Sloped Roof System) Roof System Manufacturer: Notice of Acceptance Numb Minimum Design Wind Pressures, If Applicable (From R� S 127 or Calc0aWZS)ne 3e: G•%d Zone 3r: Zone 1:f. f4 Zone 2e: 9_9 Zone 2n &' Zone - - AWN A 7 2023 BY: Deck Type: 1 wood Type underlayment .4fr.N D 3 2 4 Roof Slope: 12 Insulation: � Fire Barrier: RidgeVe 'cation. Fastener Type &Spacing: � e�✓�°c c Oe/aL y/�sH2ia�f (mod"�c \ Adhesive Type: \ Type Cap Sheet: e� EMeanRoof Roof Covering: Type & Size Drip Edge: 3 FLORIDA BUILDING CODE — BUILDING, 7th EDITION (2020) 476 ROOF ASSEMBLIES ANP;tPjEQtiC#6J-.RF.S_ .1NN q 7 202? Florida Building Code7th Edition (2020) 1 High -Velocity Hurricane Zone Uniform Permit Application Form$y: ('/srQ,�y) Section E (Tile Calculations) arre greater than or tile systems, to the M values, for eachchoose either area of the roof,pare thentthe fleues for attachmentwith method is acceptablrom e if the M, values Method 1 "Moment Based Tile Calculations Per RAS 127" (Zone 1 %1 x X -Ao = UL U - Mg: qr 'Y = Mn Y� Product Approval M, / 4 7. J� (Zone 2e-Jo x R, rel ='!1.M - M9:'f`" = M, Y' =! Product Approval M, (Zone 2n:/o V x 1,. I & - Mg: .Gv = M,Q /7� Product Approval M, / i 7 (Zone 2rr1vY x X 4 d = ?L4- J-M9:�= MaIL-Le Product Approval M, !39• y (Zone3e-�va x7w:A= lL � �-Mg: N-✓'/=M�G.7� Product Approval M, �37. s� (Zone 3nL x ?L. 2 o =-�i - Mg: = M�4 Product Approval M, i37• t� Method 2 "Simplified Tile Calculations Per Table Below" /AA % C,nm TahIP RPIOW Product Approval M, HequlreO IVIOmenl-vi He——mo Old , ,-•••----- M, required Moment Resistance' Mean 15' 20 25' 30' 40' 42.2 34.4 35.5 38.2 39.7 M412 32.2 34.4 36.0 37.4 39.6 30.4 32.2 33.8 35.1 37.3 28.426.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 __ -..aw nc Pn inn Prl By the Broward County Boa rd of Rules and or muDassa um zy •-•••_ _..____- -. -Must be used in conjunction with a fistmnm Appeals. Ulift basedtile Po , the values for P with the values the the file attachment method isacceptarble.if the F values are greater than or u arMethod 3. Compare eFor esystems qual the ea of the roof, Method 3 -Uplift Based Tile Calculations Per RAS 127" (Zone 1:— x L — _ — xw:=_�-W:—xoosr—=FI— Product ApprovalF' cos r F Product Approval F' (Zone2e:_xL—=—xw:=_a-W�-- x —= �— Product ApprovalF' (Zone 2n:_.xL---xw:=-1-W=—xcosr—=F�— (Zone2r:—xL—=—xw:=-1-W:—xcosr_=F2— Product ApprovalF' Product Approval F' (Zone 3e:—x L—=— x w: = ) - W:.— x cos r _. = Fa. — F)-W�—xcosr—= Product Approval F (Zone 3r:—xL—=—xw:=— r',— 477 FLORIDA BUILDING CODE — BUILDING, 7th EDITION (2020) ROOF ASSEMBLIES AND ROOFTOP STRUCTURES JUN O 7 2023 Florida Building Code7th Edition (2020) �--- High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) 2 SHAY/ Roof System Manufacturer. Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:/0./6 Zone 2e: d U Zone 2n:_ Zone 2r:/� Zone 3e:h[ f�Zone 3r:_ Deck Type: Type Underlayment Roof Slope: 3 : 12 insulation: I \ Fire Barrier: Ridge Ve lation? Fastener Type & Spacing: �o�y�os �<c��s �y� F/ Adhesive Type: s5;t f \ \ Type Cap Sheet 19/yes Tv .UAy Roof Covering: �[AN�.4 2�YBCC ffRdD v Fd� Mean Roof Height:�sYee Type & Siza Drip SAC Co r Edge: .3 FLORIDA BUILDING CODE — BUILDING, 7th EDITION (2020) 476 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code7th Edition (2020) JUN 0 7 2023 High -Velocity rAcane Zone Uniform Permit Application Form �1'p srleY / BY:---� Section E (Tile Calculations) he ve aFor Moment re grater than or eiqual o the le systems,Mr values, for each achoose either rea of the Croof, Phenare t he file uattaches for ment method iwith the ts acceptablfrom e If the M, values Method 1 "Moment Based Tile Calculations Per RAS 127" (Zone I -L3 x X ,1c = /+ ) - Mg: ±±f= Mn /0-/0 Product Approval MI (Zone 2e:" ifV x X lk = z o) - Mg: 4-/`y = M1,1W-14 Product Approval Mr /3x3- (Zone2n:-xl-= --j-Mg:-=Me"- Product Approval M, (Zone 2r. `»x 7 .la = - Mg: y = Mrz/-' 4 Product Approval M, '389; (Zone 3e<� x 7, - A° = -LA - MIT p_y N* N= Mra,� 44 Product Approval M, �33 r (Zone 3r:- x 1r- = _) - Mg: - = Mrjr - Product Approval M, Method 2 "Simplified Tile Calculations Per Table Below" .._�_... -4 o,.cicienre fRA I Prnm Table BeIOW Product Approval M, Hequueu rv,uu.cnw. „ „�.......... �...,, .._....-._ _. M, required Moment Resistance' Mean Roof Height Roof Slope 15' 20' �� � � 2:12 34.4 36.5 38.2 39.7 42.2 3:12 322 34.4 35.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 32.4 6:12 28.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 2-7.1 28.2 30.0 ...,...,,...� nnrin.cari by The Froward County Boal rd of Rules and "Must be used in conjunction with a list Appeals. eFor qual to the Fevfile systems use Method 3. alues, or each area of the roof, hen the tile are, the attachm attachment method is ues for F with the acceptables for e.lf the P values are greater than or Method 3 °Uplift Based Tile Calculations Per RAS 127" (Zone 1:-xL-=-xw:=- 1-W:-xcosr-=Fn- Product Approval F' (Zone 2e:- x L- _ - x w: _ _) - W: x cos r -= Ff1B - Product Approval F Product Approval - r-=Fe"- (Zone 2n:-xL-=-xW:= -W:-x cos x cos r - = F m- Product Approval F (Zone2r:-xL-=-xw:=_�-W:- (Zone 3e:._.xL-=-xw:=-)-W:--x�r-=Fa,- ProductApprovalP (Zone 3r:-xL-=-xw:=-)-W:-x cos r-=F,s,- Product Approval P Where to Obtain Information Description Symbol Where to find Zona 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analy- Design Pressure sis prepared by PE based on ASCE 7 Mean Roof Height H Job She Roof Slope 0 21 Job Site Product Approval Aerodynamic Multiplier M Product Approval Restoring Moment due to Gravity M, Product Approval Attachment Resistance M Calculated Required Moment Resistance P Product Approval Minimum Attachment Resistance Fr Calculated Required Uplift Resistance W Product Approval Average Tile Weight Tile DimensionsL =length W = width Product Approval All calculations must be submitted to the building official at the time of permit applicatin. 477 FLORIDA BUILDING CODE - BUILDING, 7th EDITION (2020) CREEK Certifko=e of Authorization No. 19824 17520 Edinburgh Dr Tampa, FL33647 TECHNICAL SERVICES,LLC- - ---= _ _ - (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7Te EDITION (2020) Distributor: GRANADA ROOF TILE INC. Issued August 12, 2020 7275 NW 6151 Street Miami, FL 33166 (786)641-9154 www.HandMadeRooMie.com Manufacturing Plants: Guatemala (Granada) Quality Assurance: Keystone Certifications, Inc. (QUA1824) SCOPE Category: Roofing Subcategory: Roofing Tiles Code Edition: Florida Building Code, 7v' Edition (2020) including High -Velocity Hurricane Zones (HVHZ) Code Sections: 1507.3.4, 1507.3.7, 1523.6.5.2, 1523.6.5.2.2 Properties: Physical Properties, Static Uplift Resistance REFERENCES Entity Report No. Standard Year American Test Lab of South Florida Inc (TST3782) RT0727.02-15 TAS 101 1995 American Test Lab of South Florida Inc (TST3782) RT0609.01-15 ASTM C 1167 2011 PRODUCT DESCRIPTION Granada, Handmade, Clay, Barrel Roof Tile Profile: ASTM C 1167, TAS 101, high profile, clay roof tile Description: TAS 101 Type 1, high profile, class III clay tile, handmade Dimensions: 17.25" x 7.75" x 3.0"; Nominal weight 6.5 lb GRAN15001.2 FL19320-R2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK---- ___= TECHNICAL SERVICES, LLC --- APPLICATION METH6B_ GRANADA ROOF TILE INC. Granada, Handmade, Clay, Barrel Roof Tile Installation for Granada, Handmade, Clay, Barrel Roof Tile Limited to slopes 3:12 or greater In the HVHZ; Outside the HVHZ, shall be in accordance Slope: with the recommendations of the FRSArrRI Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition or RAS 120. Solid or closely fitted min. 15132-inch plywood sheathing for new and existing construction Roof Deck: at max 24 in. span; In the HVHZ, new construction shall be min.19132 in. plywood at max. 24 in. span; Designed by others in accordance with FBC requirements. installed in accordance with FBC requirements. For adhesive set attachment of tile with Underlayment: ICP Adhesives Polyset AH-160 or in the HVHZ, the minimum undedayment shall be Hot Mop 30190 installed as described in RAS 118 Section 3.01. Installed in accordance with FBC requirements. For adhesive set attachment of file with ICP Adhesives Polyset AH-160 or in the HVHZ, the pan files shall be set with a 104nch center -to -center spread in a minimum 11-inch long x 44nch wide x 1.5-inch thick paddy of Attachment: ICP Adhesives Polyset AH-160 placed approximately 2.5-inches up from the nose. The cap tiles shall be adhered by placing one (1) minimum 17.25-inch long x 1-inch wide paddy of ICP Adhesives Polyset AH-160 along each longitudinal inside edge of the tile and immediately setting onto the pan tiles. Data for Attachment Calculations Nominal Weight (W) and Aerodynamic MAbft3) rs Restoring Moments due to Gravity - Mn (ft Ibf) Dimensions 0 x w) Direct Deck Roof Tile W (Ibf) L (ft) w (ft) Direct Deck 3":12" 4"A 5':12' 6":12" >T:12" — Application Granada 6.92 1A6 0.65 0.20 4.84 4.74 4.61 1 4.48 1 4.33 Attachment Resistance Expressed as a Moment Pan Tiles Cap Tiles Mr(ft-lbf) Roof Tile Pad d Paddy Adhesive Size Weights Adhesive Paddy Size' We ghts ICP ICP Granada Adhesives Polyset AH- 11'x4"A.5" 1 41.9g 1 Adhesives Polyset AH- 17.25"x1"x1" 18.5g 137.5 160 160 Notes: 1) Minimum dimensions and weight tor aonesive app icauon 7;Z_f�4CE;i v ED 1-W JUIN 0 7 2021 GRAN15001.2 FL19320-R2 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61020-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. ACREEKGRANADA ROOF TILE INC. -Granada, Handmade, Clay, Barrel Roof Tile TECHNICAL SERVICES, LLC LIMITATIONS -- "-- - - 1) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's published application instructions. Installations in the HVHZ shall comply with RAS 120. Where discrepancies exist between these sources, the more restrictive detail shall prevail. 3) Design wind load requirements shall be conducted in accordance with FBC Section 1609.5.3 in the non- HVHZ and RAS 127 in the HVHZ, using a moment based system. 4) All tiles shall bear the imprint or indelible label "Granada, Made in Guatemala". 5) In the HVHZ, a static field uplift test shall be conducted in accordance with TAS 106. 6) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building Code, 7`" Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. %�1PG?P�O E N No 74021 5 ; ¢= '9 STATE OF .'44/Z 'O.• c �: O R t�p'�j���, 10 N A' CERTIFICATION OF INDEPENDENCE 2020.08.12 17:28:05 M Wnx w,.n -041001 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will It acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT GRAN15001.2 FL19320-R2 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MIMI®M MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Polyglass USA Inc. I I11 W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 21-1217.02 and consists of pages 1 through 12. The submitted documentation was reviewed by Alex Tigera. jU N 0 7 Z023 NSA No.: 22-1221.01 MIAM4DADE COUNTY Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 1 of 12 ROOFING COMPONENT APPROVAL Category Roofing Sub -Category: Underlayment Material: SBS, APP PRODUCTS DESCRIPTION: Y CEX Y ED [J JUN 0 7 2023 B3V -- -1 Test Product Product Dimensions Specification Description Polystick IR-Xe 65' x 3' Or 33.4' x ASTM D1970 A fine granular/sand top surface self -adhering, APP Manufacturing 3' polymer modified, fiberglass reinforced, bituminous sheet Location #1, #2, & #3 60 mils thick material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. Polystick MU-X 65' x 3' ASTM D1970 A polypropylene film surface self -adhering, SBS polymer Manufacturing 60 mils thick modified, fiberglass reinforced, bituminous sheet Location #1, #2, & #4 material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. Polystick TU Max 65'8" x 3'3-3/8" TAS 103 A rubberized asphalt self -adhering, polyester reinforced Manufacturing 60 mils thick waterproofing membrane. Designed as a a roof tile Location #1, #2, & #3 underlayment. Polystick TU P 32' 10" x 3'33/8" TAS 103 A rubberized asphalt waterproofing membrane, glass - Manufacturing 130 mils thick fiber/polyester reinforced, with a granular surface Location #1, #2, & #3 designed for use as a tile roof underlayment. Polystick TU Plus 65' x 3'33/8" TAS 103 A rubberized asphalt self -adhering, glass-fiber/polyester (Surface Printing) 80 mils thick reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof tile underlayment. Location #1, #2, #3, & #5 HydraGuard Dual 65' x 3'33/8" TAS 103 A rubberized asphalt self -adhering, glass-fiber/polyester Pro 80 mils thick reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof We underlayment. Location #1, #2, #3, & #5 HydraGuard Tile Pro 65' x 3'33/8" TAS 103 A rubberized asphalt self -adhering, glass-fiber/polyester Manufacturing 80 mils thick reinforced waterproofing membrane. Designed as a metal Location #1, #2, #3, & roofing and roof tile underlayment. #5 Polystick MTS 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal Location #1, #2, #3, and #4 roofing, roof tile, slate tiles and shingle underlayment. NOA No.: 22-1221.01 Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 2 of 11 FZEC.F�V�I� PRODUCTS DESCRIPTION: Product Dimensions Polystick MTS 65'8" x 3'33/8" Manufacturing 60 mils thick Location #5 JUN 0 7 2023 Test Product RV• Specification Description ' ASTM D 1970 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick MTS Plus 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #1, #2, #3, & on the upper surface for use as an underlayment for metal #4 roofing, roof tile, slate tiles and shingle underlayment. Polystick MTS Plus 65'8" x 3'33/g" ASTM D 1970 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #5 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Elastoflex S6 G 32' 10" x 3'3 3/e" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D6164 with a sanded back face and a granule top surface. For Location #1 & #2 use in roof file underlayment systems. Polytlex SA P 32' 10" x 3' 33/8" TAS 103 and Self -adhered, polyester reinforced, APP modified Manufacturing ASTM D6222 bitumen membrane with a self -adhering back face and a Location #2 & #3 granule top surface. ELASTOFLEX SA V 65' 8" x 3' 33/s" ASTM D1970 Self -adhered, fiberglass reinforced, SBS modified Manufacturing bitumen base or interplay membrane with a self -adhering Location #3 & #4 back face and a smooth top surface. MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL 3. Waco, TX 4. Fernley, NV 5. Ponte di Piave TV, Italy NOA No.: 22-1221.01 MIAMI•DADE COUNTY Expiration Date: 09/13/27 E3 Approval Date: 04/06/23 Page 3 of 12 JUN 0 7 2023 EVIDENCE SUBMITTED Test Aeencv PRI Trinity I ERD NEMO ETC, LLC Test Identifier DAPF-002-02-01 P40390.10.12 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14-R1 P43290.10.14-111 PLYG-SC7550.03.15 PLYG-SC 10130.06.16-3 PLYG-SC 10130.06.16-1 PLYG-SC10130.09.16 PLYG-SC13035.08.17 PLYG-SC 13 320.10.17-R 1 4-PLYG-18-004.03.18 4j-PLYG- 19-S SUDL-OO.A 4S-PLYG-18-004.10.19-G 4S-PLYG-18-004.10.19-I 4S-PLYG-18-004.10-19-L 4S-PLYG-18-004.12.19-F 4j-PLYG-l9-SSUDL-02.A 4S-PLYG-18-004.01.20-H 4S-PLYG-18-004.01.20.K 4S-PLYG-18-004.01.20.A 4S-PLYG-18-004.01.203 4p-DOW-I9-SSLAP-OI.A.R2 PLYG-SC 15855.05.20-A 4S-PLYG-18-004.12.19.D 4j-PLYG-I9-SSUDL-0l .A 4j-PLYG-20-SSUDL-05.0 4j-PLYG-20-SSUDL -05.A 4p-ICP-20-SSLAP-03.A-Rl PLYG-SC 15855.06.20-B 4j-PLYG-2I-SSUDL-03.A 4j-PLYG-20-SSUDL-07.A 4j-PLYG-20-SSUDL-09.A 4j-PLYG-21-S SUDL-04.B 4j-PLYG-2I-SSUDL-09.A 4j-PLYG-2l-SSUDL-04.A.R1 4j-PLYG-22-SSUDL-01.A 4j-PLYG-22-SSUDL-02.A 4j-PLYG-22-SSUDL-03.A 4j-PLYG-2l-SSUDL-02.A BY: Test Name/Report ASTM D1623 ASTM D 1970 ASTM D6164 TAS 103, TAS 110 & ASTM D1623 ASTM D1623 TAS 103 & TAS 110 ASTM D 1970 & TAS 110 TAS 103 & ASTM D4798 TAS 103 & TAS 110 ASTM D1970 & TAS 110 ASTM D1623 TAS 103 & ASTM D4798 TAS 103 ASTM D1970 ASTM D1970 TAS 103 TAS 103 TAS 103 TAS 103 TAS 103 ASTM D1970 ASTM D1970 TAS 103 ASTM D6164 ASTM D1623 TAS 103 & TAS 110 ASTM D1970 TAS 103 TAS 103 ASTM D1970 ASTM D1623 ASTM D4073 ASTM D1970 ASTM D1623 TAS 103 ASTM D1970 ASTM D1970 TAS 103 ASTM D1970 ASTM D1970 ASTM D1970 ASTM D4073 Date 03/08/18 10/03/12 07/02/13 05/12/14 10/03/14 10/07/14 10/17/14 03/24/15 06/27/16 06/27/16 09/22/16 10/31/17 10/25/17 03/29/18 09/10/19 10/08/19 10/08/19 10/09/19 12/18/19 01/02/20 01/14/20 01/14/20 01/16/20 01/16/20 02/10/20 05/29/20 10/27/20 11/18/20 11/19/20 11/19/20 03/04/21 05/12/21 10/29/21 10/29/21 10/29/21 01/17/22 02/14/22 07/05/22 09/08/22 09/08/22 09/08/22 10/12/22 NOA No.: 22-1221.01 ML4MMADE COUNTY Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 4 of 12 LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERmiT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick NITS, Polystick NITS Plus, Polyflex SA P or ELASTOFLEX SA V, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Deck Description: System Type E(2): Anchor/Base Sheet: Fastening: Membrane: Surfacing: APPROVED Wood, non -insulated Min. 19/32" plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered One or more plies of ASTM D 226 Type II or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Elastoflex S6 G, hot asphalt applied. See General Limitations Below. RF, C F,-;t v JUN 0 7 ZOZ3 BY: NOA No.: 22-1221.01 Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 5 of 12 �E CEx VET Deck Type 1: Wood, non -insulated JUN 0 7 2023 Deck Description: Min. 19/32" plywood or wood plank BY: ---- System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Ply Sheet: Polystick MTS or Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, HydraGuard Tile Pro or HydraGuard Dual Pro, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(4): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS or Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Max, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(S): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS or Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU P", self -adhered. *This 2-Ply System will only use the Waco, TXplant. Surfacing: See General Limitations Below. NOA No.: 22-1221.01 MMLAMMADECOUNTYM Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 6 of 12 CF'1VEtiD Deck Type 1: Deck Description: System Type E(6): Anchor/Base Sheet: Fastening: Ply Sheet: Membrane: Surfacing: Wood, non -insulated JUN 0 7 2023 Min. 19/32" plywood or wood plank BY: Base sheet mechanically fastened to deck, subsequent cap membrane self- ad One or more plies of ASTM D 226 Type II or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Polystick NITS or Polystick NITS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Polystick MTS or Polystick NITS Plus, self-adbered. See General Limitations Below. INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the fast course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a right fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 22-1221.01 MIAMMADE COUNTY Expiration Date: 09/13/27 FM Approval Date: 04/06/23 Page 7 of 12 RF,CEs v £iD GENERAL LIMITATIONS: JUN 0 7 202 ) 1. Fire classification is not part of this acceptance. By 2. Polystick TU Plus, HydraGuard Dual Pro, and HydraGuard Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, adhered roof tile using adhesives listed in the table below, and mechanically fastened roof tile systems and quarry slate roof assemblies. Polystick MTS, and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non- structural metal roofing, mechanically fastened roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in asphaltic shingles, wood shakes and shingles, adhered roof tile using adhesives listed in the table below, and mechanically fastened roof file systems and quarry slate roof assemblies. Polystick Ht-Xe may be used in asphaltic shingles, wood shakes and shingles, and quarry slate roof assemblies. Polystick TU Max may be used in non-structural metal roofing, adhered roof tile using adhesives listed in the table below, and mechanically fastened roof tile systems. Elastoflex S6 G, and Polyflex SA P may be used in adhered roof tile using adhesives listed in the table below and mechanically fastened roof file systems. ELASTOFLEX SA V may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, mechanically fastened roof file systems and quarry slate roof assemblies. Roof Tile Adhesives Approved for Use with Tile Underlayment ICP Adhesive Polyset RTA-1 ICP Adhesive Polyset AH-160 DAP Storm Bond® 2 Roof Tile Adhesive DuPont TILE BOND m Roof Tile Adhesive Polystick TU Plus yes yes yes yes HydraGuard Dual Pro yes yes yes yes HydraGuard Tile Pro yes yes yes yes Polystick TU P yes yes yes n/a Polystick TU Max yes yes yes yes Elastoflex S6 G yes yes n/a n/a Polyflex SA P n/a yes n/a n/a 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick Ht-Xe, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS, Polystick MTS Plus, Elastoflex S6 G, Polyflex SA P or ELASTOFLEX SA V shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS, Polystick MTS Plus, Elastoflex S6 G, Polyflex SA P or ELASTOFLEX SA V shall not be adhered directly over a pre-existing roof membrane as a recover system. NOA No.: 22-1221.01 Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 8 of 12 6. Polystick IR-Xe, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, HydraGuard Dual Pro, HydraGuard Tfle Pro, Polystick NITS, Polystick NITS Plus, Elastoflex S6 G, Polyflex SA P or ELASTOFLEX SA V shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days) Winter Haven, FL Hazelton, PA Waco, TX Fernley, NV Ponte di Piave TV, Italy Polystick NITS 180 180 180 180 n/a Polystick Ht-Xe 90 90 90 n/a n/a Elastoflex S6 G 180 180 n/a n/a n/a Polystick TU Plus 180 180 180 n/a 180 Polystick TU P 180 180 180 n/a n/a Polystick TU Max 180 180 180 n/a n/a Polystick NITS Plus 180 180 180 180 n/a Polystick MU-X 180 180 n/a 180 n/a HydraGuard Dual Pro 180 180 180 n/a 180 HydraGuard Tfle Pro 180 180 180 n/a 180 Polyflex SA P 180 n/a 180 n/a n/a ELASTOFLEX SA V n/a n/a 30 30 n/a All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and 7. Rule �61 G20-3 of the Florida Administrative Code. RECF«�iT�p JUN U 7 2023 BY: NOA No.: 22-1221.01 Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 9 of 12 8. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Slippage Limitations for Direct -to -Deck Tile Assemblies Underlayment Tile Profile Staging Method Maximum Slope Elastoflex S6 G Flat / Profiled Max. 6-tile stack (4 over 2) 4:12 Polystick TU P Flat / Profiled Max. 6-tile stack (4 over 2) 6:12 Polystick TU Plus, HydraGuard Dual Pro, HydraGuard Tile Pro Flat / Profiled Max. 6-tile stack (4 over 2) 7:12 Polystick TU Plus, HydraGuard Dual Pro, HydraGuard Tile Pro Flat / Profiled Max. 10-tile stack 6:12 Polystick TU Max Flat / Profiled Max. 6-tile stack (4 over 2) 6:12 Polystick MTS, NITS Plus Flat Tile Max. 6-tile stack (4 over 2) 5:12 Profiled Tile Max. 6-tile stack (4 over 2) 4.12 Profiled Tile Max. 6-tile stack (4 over 2) 5:12 Polystick Two -Ply Underlayment Systems Polystick NITS Plus with Polystick TU Plus, HydraGuard Dual Pro or HydraGuard Tile Pro Flat Tile Max. 6-tile stack (4 over 2) 7:12 Profiled Tile Max. 6-tile stack (4 over 2) 6:12 Polystick NITS Plus with Polystick TU Max Flat Tile Max. 6-tile stack (4 over 2) 7:12 Profiled Tile Max. 6-tile stack (4 over 2) 6:12 Polystick NITS Plus with Polystick TU P Flat Tile Max. 6-tile stack (4 over 2) 6:12 Profiled Tile Max. 6-tile stack 4 over 2 5:12 The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall be utilized during loading and installation of tiles. 9. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four file stack parallel to the slope, for a total of 6 tiles. &&IS %of Deck prepared W th POLMCKTU Plea NOA No.: 22-1221.01 Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 10 of 12 10. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS, Polystick MTS Plus, Elastoflex S6 G, Polyflex SA P or ELASTOFLEX SA V may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS, Polystick MTS Plus, Elastoflex S6 G, Polyflex SA P or ELASTOFLEX SA V as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS, Polystick MTS Plus, Elastoflex S6 G, Polyflex SA P or ELASTOFLEX SA V are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. tTz1Cnj(V)MO JUN 0 7 2023 BY:. NOA No.: 22-1221.01 Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 11 of 12 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LEMTATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus, HydraGuard Dual Pro or HydraGuard Tile Pro should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a mint 1 %of metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus, HydraGuard Dual Pro or HydraGuard Tile Pro should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading file on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #8 and #9. 6. Battens and/or Counter -battens, as required by the file manufacturers NOA, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 VV/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. S. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 351bs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LINIITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS END OF THIS ACCEPTANCE NOA No.: 22-1221.01 Expiration Date: 09/13/27 Approval Date: 04/06/23 Page 12 of 12 MIMI M JUN U 7 2023 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION — 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy ICP Construction Inc. 150 Dascomb Road Andover, MA 01810 BY: SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyset® AR-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 22-0411.02 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 22-0614.10 Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 1 of 11 1YC14% V r D ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: BY: JUN 0 7 2023 This approves Polyset® AH-160 as manufactured by ICP Construction, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications Polyset®AH-160 N/A TAS 101 Two component polyurethane foam adhesive ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPack® N/A Dispensing Equipment 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Density @ 73'F ASTM D1622 Compressive Strength ASTM D1621 Tensile Strength ASTM D1623 Water Absorption ASTM D2842 Moisture Vapor Transmission ASTM E96 Dimensional Stability ASTM D2126 Closed Cell Content ASTM D6226 Results 2.1 lbs./ft.' 18 PSI Parallel to rise 14 PSI Perpendicular to rise 29 PSI Parallel to rise 0% 2.3 Perms +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @1580F., 100% Humidity, 2 weeks 94% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 22-0614.10 Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 2 of 11 EVIDENCE SUBMITTED: JUN 0 7 2023 Test Aeencv Test Identifier Test Name/Report BY: Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 NEMO ETC, LLC 4p-ICP-20-SSLAP-01.B Physical Properties 11/11/20 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polyset® AH-160 roof the adhesive with their the assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 22-0614.10 MLOMFDADECOUNTY Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 3 of 11 RECnI ED JUN 0 7 2R'i INSTALLATION: l�� 1. Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of Polyset® AH-160. 2. Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof file assembly's adhesive attachment with the use of Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA. 3. Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Construction, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by ICP Construction, Inc. ICP Construction, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. 7. Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after Polyset® AH-160 has been dispensed. 9. Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 22-0614.10 Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. MIAMIQWE COUNTY BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. RECE %, EjD Juju 0 7'-,' i NOA No.: 22-0614.10 Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 5 of 11 ADHESIVE PLACEMENT DETAIL ## 1 Nail through plastic cement Paddy(Baneathrile) (when required) Underlayment 1 ° R\\ 10 In.. . Battens optional ° Eave Castes* ° °10 itt. Fascia Eave Closun Eave Ciosun Fascia Nail through plastic c (whenrequired) Paddy (Beneath Tile) Undetiayment 1 101n.: 21n.whio Battens optional ll Ewa Course Fascia Waephole 101n. 21n. Eave closure Dripedge Flat/Low Profile Tile I. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the file being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 22-0614.10 Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 6 of 11 I CE;i w il�iD ADHESIVE PLACEMENT DETAIL ## 2 Nall through plastic cement Paddy (Beneath Tile) (when retiuired) UI nderla) ent io 1t 7in. 21n. Battens optional ° Eave Course a z yx Win. _"�O�v Fascia 210 Eave Closure plasticcement IBen earl, Tilel Battens Eave Closure Fascia ---TA—PPROVEDII Flat/Low Profile Tile BY: JUN 0 i zoz3 1. Starting at the eave course, apply a minimum 2" (50.8 torn) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm) - 12 (77.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 torn) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on nextpage) NOA No.: 22-0614.10 Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 7 of 11 V i. ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nail through plastic ce Iwhen required) Daddy (Beneath Tile) Undedayment r 7 in.. '. 2 m. Battens optional , Eave Course Fascia Weephole 10 in. 2 in. Eaveclosure Drip edge BY: High Profile / Single Pan Tile JUN 0 7 2023 Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm) - 19 (122.6 cm) square inch adhesive contact with the underside of the tile. NOA No.: 22-0614.10 Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 8 of 11 ADHESIVE PLACEMENT DETAIL ## 3 Nail throughplasticcement Paddy 6aneen din) (when required; /\ I Bmens optional�'i Paddy(under tile) Sin t le of= pa t an top dtde r , again. I V, _ 5ugle paddy /••`•'• _.. under ti smglepaddy / oo underlayment e 2a a in. t0 Fascia Bsetlmue Flat/Low Profile Tile Hail through plastic cement Single paddy under tile (when requ(red) Paddy(betrreen tiles) Battens / Paddy(under tilel optional � of�� . 'F / twain. 1VU g4in.1' '* San I 101n. 21n — Fare Ckanre Eve Crone Fascia Maillum ProllkTOe APPROVED 1. On the eave course only, apply a minimum 2" (50.8 turn) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in2 (109.7-148.4 cm) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x V (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in2 (51.6-58.1 cm) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 22-0614.10 Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) tile) C,=— 3 High ProttleTile JUN 0 7 2023 BY. 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 mm) paddy on top of the eave course file surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the rile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 22-0614.10 MIAMFD/1DECOUNTY Expiration Date: 05/10/27 6 t Approval Date: 10/13/22 Page 10 of 11 Fc1ECF�i V F: !D ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq.in. Steep pitch applications in contact with the pan tile. (when required) 2) Tom covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area. IUnderlayment Sheathing Eave closure (motarshown) Weephole Fascia Board pemove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel -High Profile Tile Julu 0 7 M EEM Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave riles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the rile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover file over after foam is applied and place onto pan file course. Insure a minimum of 20 (129 cm) - 25 (161.3 cm') square inch contact area on each side of the cover file to the pan rile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 22-0614.10 Expiration Date: 05/10/27 Approval Date: 10/13/22 Page 11 of 11 Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Permit NO.: RC-06-23-1456 Permit Type: Building (Residential) Work Classification: Alteration Permit Status: Approved Issue Date:06/22/2023 I Expiration: 12/22/2023 Parcel Number 1245 NE 96TH ST, Miami Shores, FL 33138 1132060143780 Contacts CURTIS BRODSKY Owner 1245 NE 96 ST, MIAMI SHORES, FL 33138 crbrodsky@aol.com LESTER JENSEN 1665 NE 137 TER, MIAMI, FL 33181 Business: 3058926507 Other: 3058926507 arcoconstruction@aol.com Description: INSTALLATION OF RIGHT ANGLE ROOF GUSSETS Fees Amount Application Fee - Other $50.00 CCF $7.20 DBPR Fee $5.40 DCA Fee $3.60 Education Surcharge $3.60 Permit Fee $310.00 Scanning Fee $9.00 Structural Review ($60) $60.00 Technology Fee $36.00 Total: $484.80 .com Sandy Hart 9822 ne 6avenue 9, Miami shores, FL 33138 Business: 3057572612 harttwohart5@aol.com Mobile: 9548022965 Home: 3057577861 Other: 3053311200 Valuation: $ 12,000.00 Total Sq Feet: 350.00 Inspecrion Requests: _ 305-762-4949 Payments Date Paid Amt Paid Total Fees $484.80 Check# 11884 06/22/2023 $484.80 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner I Applicant / Contractor / Agent Date June 22, 2023 Page 2 of 2 G�IVEit� Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION dBUILDING ❑ ELECTRIC ❑ ROOFING ❑PLUMBING ❑ MECHANICAL ❑ CHANGE OF CONTRACTOR JOB ADDRESS: / ��� / %G S JUN U 7 2023 FBC 2020 - Master Permit No. �F- O( z3 L(&S Sub Permit No. ko - 0L -2,' " ILI SZv ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CANCELLATION ❑ SHOP DRAWINGS City Miami Shores County: Miami Dade Zip: 33 / 3 it Folio/Parcel#: // 6/4 - 37 74 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titlehholder): (_yyT/S-&-ew-vey Phone#: 50S60Y-7y�� Address: I p qf- lur z 6 j) _ City: 142'r / Sh0 ✓f -3 State: FL Zip: 3 3/ 3 Tenant/Lessee Name: Email CONTRACTOR: Company Name: 2f� ��NGi �)�,r (1 /x9G'�C� Phone#: Address: i)4�7�% Email: aVCQ(,, V1-?±Ir ( z'15 C CC Qualifier Name: State Certification or Registration #: Certificate of Competency #: 2x� 5 sE ( 2 i` DESIGNER: Architect/Engineer: J " bol- Phone#: Address: City: State: Zip: i Value of Work for this Permit: $ /�/ 6 0 o Square/Linear Footage of Work: 3S� Type of Work: ❑ Addition ❑ Alteration ❑ New ® Repair/Replace ❑ Demolition Specify color of color thru tile: "V i /'4- Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ DCA Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ P&Z Review $ Bond $ TOTAL FEE NOW DUE $ — (Revised04/05/2022) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $1500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged beforemethis _ day of u46a,`E e 20 G7 by CUi s 31 �Ls l<.I who is personally known to me or who has produced identification and who did take an oath. NOTARY Print: 'z�'•`6i'• ATHERINE A•D IN Seal: _ MY COMMISSION p HH 089 EXPIRES: May 14, 2025 M``E•`,... 6ondad Thm Notary Pub!., r. •asssssssssssssssstasssssasasssa APPROVED BY 9 day of /( (/L( 20 Z S by Lp s, (_z �� �sy who is personally known to as me or who has produced identification and who did take an oath. NOTARY as Sign: r`` 'u ( " old TlN Notary pubic ai tti tatatassasatata iatgatsassia 4MNR'a iss Hsaa _ Plans Examiner ' ( � is �°�) Zoning OG(l(r��3 1&i& Structural Review Print: Seal: CATHERINE A. _ My�� UFFIN • MMISSION A HH 089522 EXPIRES: May f4, 2025 q? Clerk (Revised04/05/2022) OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-0143780 Property Address: 1245 NE 96 ST Miami Shores, FL 33138-2553 Owner CURTIS R BRODSKY BARBARA WEINER Melling Address 1245 NE 96 ST MIAMI, FL 33138 USA PA Primary Zone 1400 SGL FAMILY - 3001-3250 SO Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds I Baths / Half 5 / 4 / 0 Floors 2 Living Units 1 Actual Area 4,803 Sq.Ft Living Area 3,662 Sq.Ft Adjusted Area 3,884 Sq.Ft Lot Size 20,250 Sq.Ft Year Built 1925 Assessment Information Year 2022 2021 2020 Land Value $1 2215,324 $765,716 $765,716 Building Value $393,838 $270,326 $272,679 XF Value $33,867 $34,259 $34,650 Market Value $1,643,029 $1,070,301 $1,072,945 Assessed Value $1,643,029 $362,009 $357,011 Benefits Information Benefit Type 2022 2021 2020 Save Our Homes Cap Assessment Reduction $708,292 $715,934 Homestead Exemption $25.000 $25.000 Second Homestead Exemption $25,000 1$25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 3 PB 10-37 LOTS 5 TO 7 INC BLK 83 LOT SIZE IRREGULAR OR 17922-2889 1297 4 Generated On : 5/11/2023 Taxable Value information 2022 2021 2020 County Exemption Value 1 $0 $50,0001 $50,000 Taxable Value 1 $1,643,0291 $312,0091 $307,011 School Board Exemption Value $0 $25,000 $25,000 Taxable Value $1,643,0291 $337,0091 $332.011 City Exemption Value $0 T $50,000 $50,000 Taxable Value 1 $1,643,0291 $312,0091 $307,011 Regional Exemption Value $0 $50,000 $60,000 Taxable Value 1 $1,643,0291 $312,0091 $307,011 Sales Information Previous OR Book- Pdca qualification Description Sale Page 34584 2685- 08/09/2021 $2,000,000 Ouai by exam of deed 17922- Sales which are disqualified as a result 12101/1997 $0 2889 of examination of the deed 00000- 11/01/1974 $130.000 Sales which are qualified 00000 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disdaimerasp Version: eCIS Home I Log In I User Regls don db a ®Product Approval CITYUSER: PUEIic Use. PmauR Aooroval Menu > PraauR ar AgRlication Search > Asullcatlon List > Application Debil FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Evaluation Entity Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FLvision R6 PY Revision 2020 CO Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Miami gSgho Shores �Wlqe B ilding Dep tm nt Zonin De t. Date ISimpson Strong-Tle Co. Buildin DB tDat 2151 S. Airport Drive Subject to compli ith all ed ral, McKinney, TX 75069 State and county rules and regulations. (800) 999-5099 Ext 3027 Rn K D 6 _ Z3 _ kcullum@strongtie.com Permit# Admin IAPMO UES barry.johnson@uniform-es.org U i /A Keith Cullum (New) lii'�L RE 2151 S. Airport.Dr: l n— — Shelby Short S956 W. Las Positas Boulevard Pleasanton, CA 94588 (800) 999-5099 sshort@strongtie.mm Structural Components Wood Connectors Evaluation Report from a Product Evaluation Entity IAPMO Uniform Evaluation Services LLC. IAPMO UES 12/31/2023 IAPMO Uniform ES 6 COI JAPMOE rtif- of Independence.P13F Standard AISI S100 ANSI/AWC NDS ASTM D7147 /"'A16 4+-5 V 2016 2018 2011 RECl�wItEH JUN 0 7 2023 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summery of Products Go to Page 0 Method 1 Option C 11/16/2020 11/20/2020 11/28/2020 00 Page 1/200 FL # Model, Number or Name Description 10446.1 A21, A23, A33, A34, A35, A44 Angles Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL10446 R6 II er 0112.12df Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: If used to resist wind uplift in HVHZ, provide FL10446 R6 AE er 0112.odf supplemental connectors to achieve minimum 700 lbs. 10446.2 APA21, APA4, APA6, APVA21, Outdoor Accents Angles APVA4, APVA6 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL10446 R6 II er 0280.odf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services I.I.C. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: If APA21 or APVA21 are used to resist wind uplift in FL10446 R6 AE er 0280.pdf HVHZ, provide supplemental connectors to achieve minimum 700 Its. 10446.3 APB44, APB44R, APVB66, APB66R, Outdoor Accents Post Bases APB88, APB88R, APB1010, APB1010R, APVB44, APVB44R, APVB66, APVB66R, APV888, APVB88R,APVB1010,APVB1010R Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL10446 R6 II er 0280.ggf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: FL10446 R6 AE er 0280.pdf 10446.4 APDJT2-4, APDJT2R-4, APD3T2-6, Outdoor Accents Deck Joist Ties APD3T2R-6, APVDJT2-4, APVD3T2R- 4, APVDM-6, APVD3T2R-6 Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL10446 R6 II er 0280.odf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services I.I.C. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: Products have not been evaluated for uplift FL10446 R6 AE er 0280.p ff resistance. 10446.5 APHH46, APHH46R, APHH610, Outdoor Accents Heavy Hanger APHH61OR Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL10446 R6 II er 0280.odf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: FL10446 R6 AE er 0280.p-df 10446.6 APL4, APL6, APT4, APT6, APVL4, Outdoor Accents L and T Beam -to -Column Ties APVL6, APVT4, APVT6 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL10446 R6 11 er 0280 odf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Design Pressure: N/A Other: 10446.7 APLH24, APLH24R, APLH26, APLH26R,APLH210,APLH210R Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If APLH24 or APLH24R are used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. Created by Independent Third Party: Evaluation Reports FL10446 R6 AE er 0280.odf Outdoor Accents Light Hangers Installation Instructions FL10446 R6 II er 0280.1?df Verified By: IAPMO Uniform Evaluation Services U.C. Created by Independent Third Party: Evaluation Reports FL10446 R6 AE er 0280 pdf 110446.8 1 BVLZ I Brick Veneer Ledger Connector Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Product has not been evaluated for uplift resistance. 10446.9 CBT2Z, CBT4Z Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL10446 R6 tI er 0280.odf Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL10446 R6 AE er 0280.pdf Concealed Beam Ties Installation Instructions FL10446 R6 II er 0280.12df Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL10446 R6 AE er 0280.pdf 110446.10 1 CJT3Z, CJT4Z, CITSZ, CIT6Z I Concealed Joist Ties Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 10446.11 DJT14 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Product has not been evaluated for uplift resistance. 10446.12 1 DS Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Product has not been evaluated for uplift resistance. 10446.13 R , FC6 Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL10446 R6 II er 0280.odf Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL10446 R6 AE er 0280.12df Deck Joist Tie Installation Instructions FL10446 R6 II er 0280.pdf Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL10446 R6 AE er 0280.p�f Dry Wall Stop Installation Instructions FL10446 R6 II er 0280.pdf Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL10446 R6 AE er 0280.odf Framing Clips Installation Instructions FL10446 R6 II er 0112.odf Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL10446 R6 AE er 0112.pdf 110446.14 1 FWANZ I Foundation Wall Angles Limps of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 10446.15 1 GAI, GA2 Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL10446 R6 II er 0112 odf Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL10446 R6 AE er 0112.odf Gusset Angles Installation Instructions FL10446 R6 II er 0112.pdf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: If used to resist wind uplift in HVHZ, provide FL10446 R6 AE er 0112.p,Qf supplemental connectors to achieve minimum 700 lbs. 10446.16 H2A, H2.5T, H8, H10A-2, H10S, Hurricane Ties H14, HGA30 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL10446 R6 II er 0112.odf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: If H2A, H2.5T, or HGA10 are used to resist wind uplift FL10446 R6 AE er 0112.pdf In HVHZ, provide supplemental Connectors to achieve minimum 700 lbs. 10446.17 HCJTZ Heavy Concealed Joist Tie Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL10446 R6 II er 0280.pdf Approved for use outside HVHZ Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: FL10446 R6 AE er 0280.pdf 10446.18 HH4, HH6 Header Hangers Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL10446 R6 It er 0112.pdf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: If HH4 Is installed on a single 2x post and used to FL10446 R6 AE er 0112.pdf resist wind uplift In HVHZ, provide supplemental connectors to achieve minimum 700 Its. 10446.19 KBS1Z Knee -Brace Stabilizer Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL10446 R6 II er 0280.Ddf Approved for use outside HVHZ: Yes Verifed By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: If used to resist wind uplift in HVHZ, provide FL10446 R6 AE er 0280.pdf supplemental connectors to achieve minimum 700 lbs. 10446.20 L30, 1-50, L70, L90 Angles Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL10446 R6 II er 0112.udf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services I.I.C. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: If L30 or L50 are used to resist wind uplift In HVHZ, FL10446 R6 AE er 0112.pdf provide supplemental connectors to achieve minimum 700 Its. Go to Page 0 Back M FMA 00 Pagel/200 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an ANEW employer. Copyright 2007-2013 State of Florida.:: Privacy statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your ¢-mall address released in response to a public -records request, do not send electronic mall to this entity. instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. "Pursuant M section 455.275(1), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide Me Department with an email address if they have one. The malls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which an be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dick bi Product Approval Accepts: Credit Card Safe Nome Connectors Wood Construction Connectors Masonry Connectors Truss Tiedowns for Masonry Ilurricane Ties for Masonry HGAM Hurricane Gusset Angle for Masonry N X 3 �® Wood Construction Connectors 2021-2023 A catalog including new product information as well as any applicable specification and installation instructions for wood -to -wood and wood -to - concrete stmeturel connectors. Product Details The HGAM is designed to secure the bottom chord of a gable end truss or other framing member to masonry. The engineered gusset In the angle increases strength for lateral and uplift loads. This hurricane gusset angle Installs easily with 1 1 /2' Strong -Drive® SDS Heavy -Duty Connector screws and Titen Turbo" masonry screws to concrete or masonry. Key Features • Engineered for increased loads in high -wind or seismic events • Also available in kits with Strong -Drive SDS and Titen Turbo screws • Strong -Drive SDS screws are high -strength structural screws that Install with no predrilling because of their patented, easy driving Type-17 point Material • 14 ga. Finish • Galvanized Installation • Use all specified fasteners; see General Notes • Connectors attached using hex -head Titen Turbo screws • Products shall be installed such that the Titen Turbo screws are not exposed to the exterior environment • Attach to grout -filled CMU with a minimum one ri5 rebar horizontal in the course • Hurricane ties do not replace solid blocking Related Links Wood Construction Connectors Technical and installation Notes General Corrosion Information Catalog Pages • ® C-C-2021 (Wood Construction Connectors)pages 252-253 Conectores para la construcci6n con madera 2021-2023 El cat3logo incluye informati6n sobre nuevos productos, asi como especificaciones a instmcciones de instalaci6n aplicables pare conectores estructurales de madem a madera y de madera a concreto. vaPsory High Wind Guide A comprehensive guide to help Designers select the most appropriate connections for challenging, high -wind regions. IGF Larnecrors iI� y ICF Connectors I-( ICPVL19—Flo, A flier featuring installation instructions for the ICFVL ledger connector system and provides information on the various products we have to serve the ICF market. Load Tables High -Wind Retrofit Solutions for Homeowners .nJk irr,: _ _. A flier providing recommendations on reducing the risk of hurricane- and other wind -Induced damage to existing homes. Connectors for Florida Hurricane Mitigation Retrofit When Re - Roofing A technical bulletin explaining how to achieve sufficient uplift capacity for roof -to -wall connections, with references to the 7th edition (2020) of the Florida Building Code. Fasteners (in.) OF/SP SPF/HF Allowable Loads Allowable Loads Model No. Ga. Uplift Lateral Lateral Uplift To Rafter/Truss To GFCMU TO Concrete (160) I (160) (1so1 Fr Fz (160) Fr Fz HGAM10KIA 14 (4)1/4x112SDS (4)1/4x23/4Titen Turbo (4) 114 x 1314 Tden Turbo 810 875 1,tO5a 585 630 795 1. Loads have been Increased for wind or earthquake loading, with no further increase allowed. Reduce where other loads govern. 2. HGAMI OKTA allowable loads are for one anchor. A minimum rafter thickness of 21/2" must be used when framing anchors are installed on each side of the rafter or truss. 3. Concrete shall have a minimum compressive strength of f � = 2,500 psi. 4. Grout -filled CMU (GFCMU) shall have a minimum compressive strength of f', = 1,500 psi. 5. The HGAMI OKTA is a kit with (10) HGAM10 connectors packaged with Stang -Drive SDS Heaw-Duty Connector screws and 2 3/4' Titen Turbo screws. (1 3/4' Titen Turbo screws for concrete installations sold separately.) 6. HGAM10 F. loads are for forces into the connector. Fz loads away from the connector are 640 lb. (DF/SP) and 460 lb. (SPF/HF). Moisture barrier not shown (typ.) away from connector) nin. HGAM10 Installed into Masonry Code Reports & Compliance Product Series HGAM Compliance/Certification Florida Building Code Footnotes 1. Please review compliance documents for information about specific product models. In some cases, Compliance documents cover most but not all models associated with a product series. 2. For additional Information regarding Florida's Statewide Product Approval System and Miami -Dade County Notice of Acceptance (NOA), 2U& hitma Related Products Strong -Drive® SDS HGA HEAVY-DUTY Hurricane Gusset Angle CONNECTOR Screw Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msyfl.9ov 14 11 toyd Tel ►III: U-1Io1iAk1 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. G� Aesthetics -Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. C iZ,,�5 Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Lz)77 Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. l2P% Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. S. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfi.sjov 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. CiZF7 Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Owner/Agent's Signature Date ntractor Signature Date For Forms and Applications click here: http://bldg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia miShoresVillage Ron DeSantis, Governor STATE OF FLORIDA Melanie S. Griffin, Secretary dbp hr DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD THE GENERAL CONTRACTOR HEREIN IS CERTIFIED UNDER THE PROVISIONS OF CHAPTER 489, FLORIDA STATUTES JENSEN, LESTER ARCO CONSTRUCTION CORPORATION 1299 NE 104 STREET MIAMI SHORES FL 33138 LICENSE NUMBER: CGC1505163 EXPIRATION DATE: AUGUST 31, 2024 Always verify licenses online at MyFloridaLicense.com Do not alter this document in any form. This is your license. It is unlawful for anyone other than the licensee to use this document. Local Business Tax Receipt Miami —Dade County, State of Florida THIS IS NOT A BILL— DO NOT PAY 275WS BUSINESS NAMS&OCATION ARCO CONSTRUCTION CORP 1299 NE 104TH ST MIAMI SHORES. FL 33136-2659 OWNER ARCO CONSTRUCTION CORP CIO LESTER JENSEN QUALIFIER vvoeiter(s) RECEIPT NO. RENEWAL 2889732 L 11 mT EXPIRES SEPTEMBER 30, 2023 Must be displayed at place of business R Pursuant to County Coat M*. Chapter SA — Art. 9 & 10 SEC. TYPE OF BUSINESS 196 GENERAL BUILDING CONTRACTOR CGC1505163 PAYMENT RECEIVED BY TAX COLLECTOR 45.00 091=022 0210-22-003520 This Local Suuacw Tax ftceipt a my con&= payment of *a Local eu:dnm Tax. The Receipt is n t a race mcs permit or a codfic tioo of the holder's qualibudom to do budne m Nolder must cexuply with any 9aa►crrumeatel eu eaapoyer reralatory lam mad n*incaec m which apply to the buthom The RECEEPT NQ ebe emtst be d oo aD commuchd altitles — Wami.Ebde Codo See: Sa M r aornoac� for MGM iafettasstioa. visit ACORN® CERTIFICATE OF LIABILITY INSURANCE `.� DATE(18/DDIYYYY) o7i/2o2z THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terns and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsements . PRODUCER °O TAcr Stacy Parks Insurance Industries PHONE 305 891-2808 305 891-6367 SL . stacy@insuranceindushiesine.com 953 NE 125th St. INSURERS) AFFORDING COVERAGE NAIC # INSURER A: PENN AMERICAN INSURANCE COMPANY North Miami FL 33161 INSURED INSURER B : INSURER c : ARCO CONSTRUCTION CORP INSURER D : 1665 NE 137 TERR INSURER E : INSURER F : North Miami FL 33181 COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. [NSR TYPE OF INSURANCE DL BR POLICY NUMBER POLICY EFF POLICY EXP LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1000000 CLAIMS -MADE a OCCUR DAMAGE TO RENTED ISES (Ea occurrengJa $ 100000 MED EXP (Any oneperson) $ 5000 PERSONAL & ADV INJURY $ 1000000 A Y Y PAV0266190 7/12/2022 7/12/2023 GEML AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2000000 POLICY PRO-- D LOC PRODUCTS - COMP/OP AGG S 2000OW $ OTHER: AUTOMOBILE LIABILITY COMBI aED SINGLE LIMIT (Ea accent $ BODILY INJURY (Per person) $ ANY AUTO OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY (Per acddertQ $ PROPERTY DAMAGE a $ HIRED NON•OVVNED AUTOS ONLY AUTOS ONLY UMBRELLA LIAS OCCUR EACH OCCURRENCE $ AGGREGATE $ EXCESS LIAB CLAIMS -MADE QED RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y 1 N ANY PROPRIETOR/PARTNER/EXECUTIVE PER OTH- STATUTE ER E.L. EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? ❑ N !A (Mandatary In NH) E.L. DISEASE - EA EMPLOY $ If yes. describe under DESCRIPTION OF OPERATIONS below EL DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If more space Is required) RESIDENTIAL REMODELING, CARPENTRY CGC#1505163 CERTIFICATE HOLDER IS LISTED AS ADDITIONAL INSURED SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN MlAMI SHORES VILLAGE BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2 AVE AUTHORIZED REPRESENTATIVE MIAMI SHORES FL 33138 O 1988 2015 ACORD CORPORATION. All rights reserved. ACORD 25 (2016103) The ACORD name and logo are reglstered marks of ACORD JIMMY PATRONIS CHIEF FINANCIAL OFFICER STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW * * CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 4/1/2023 PERSON: LESTER JENSEN FEIN: 650353747 BUSINESS NAME AND ADDRESS: ARCO CONSTRUCTION CORPORATION 1665 NE 137 TERRACE MIAMI, FL 33181 EXPIRATION DATE: 3/31/2025 EMAIL: PSINCO@AOL.COM This certificate of election to be exempt is NOT a license issued by the Department of Business and Professional Regulation. To determine if the certificate holder is required to have a license to perform work or to verify the license of the certificate holder, go to www.myfloridalicense.com. IMPORTANT: Pursuant to subsection 440.05(13), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to subsection 440.05(11), F.S., certificates of election to be exempt Issued under subsection (3) apply only to the corporate officer named on the notice of election to be exempt. Pursuant to subsection 440.05(12), F.S., notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT E01695185 QUESTIONS? (850) 413-1609 RULE 69L-6.012, F.A.C. REVISED 012023 ��EiVEI- JUN 0 7 2023 BY: C411t_ Notice to Owner — Workers' Com Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Insurance Exem Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if: 1. The officer owns at least 10 percent of the stock of the corporation, or in the case of an LLC, a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State, Division of Corporations; and 3. The corporation is registered and listed as active with the Florida Department of State, Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use day labor, part-time employees or subcontractors for your project The contractor has provided an affidavit stating that he or she will be the only person allowed to work on your project In these circumstances, Miami Shores Village does not require verification of workers' compensation insurance coverage from the contractor's company for day labor, part-time employees or subcontractors. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. Signature: A7,& O)vaer State of Florida Coumy of Miami -Dade f1, ^ The foregoing was acknowledge before me this day of �JNV 20_Zo3 By CL h- t - S (f ro eSt �i who is personally known to me or has produced �n tip` ? '> IDOR E. KIDD BARALT Notary: !`:"`: Notary Public • State of Florida y� Commission N HH 344658 SEAL:Pr2027 MY Comm. Expires Mar t5, Assn. "Bonded through National Notary Arco Construction Corporation RECEIVED JUN 00�7 Z023 BY: " May 25, 2023 State of Florida County of Miami Dade Before me this day personally appeared Lester Jensen who, being duly sworn deposes and says: That he will be the only person working on the project located at: 1287 NE 96 Street, Miami Shores, FL 33138 Sworn to (or affirmed) and subscribed before me this 25 day of May. 2023 ,by Personally know Or Produced Identification Type of Identification r µ• --� CATHERINEA DUFFIN P int,//T/y/pe or Stamp N e of Notary MY COMMISSION#HH08A622 �a `aa; q P? EXPIRES; May 14, 2018 Bonded T6N Noum General Contractors/CGC1505163/1665 N.E. 1371h Terrace/N. Miami, Fl, 33181 305.892-6507 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 PT0T�TJ JUL 06 M3 UI INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC WZ BUILDING Master Permit No.;; kr-1 jZ —)3 PERMIT APPLICATION Sub Permit No.1C*a/ ��-1�1 ❑BUILDING ❑ ELECTRIC ROOFING dREVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: Folio/Parcel#: A 3 2 d G U / y3 2�e- Is the Building Historically Designated: Yes V/ NO _ Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): ( 1�I, Address: 7� City: l<i%'y�r Ski[%✓phi State: Tenant/Lessee Name: �— Email: CONTRACTOR: Company Name: (- /j/ UVt1(jVT% Address: '� l� �• Email: T TV,,\ o v re) 4,0 Qualifier Name n (' 7 ' 0�)' State Certification or Registration #: DESIGNER: Architect/Engineer: J 14f k d C/ r\A V 1 Value of Work for this Permit: Type of Work: ❑ Addition Description of Work: ❑ Alteration Specify color or color tnru ti►e: r P:3�13 � 4 of Competency #: Ik Phone#:S _City: State: Zip: Square/Linear Footage of Work: q� ' 0L' �� IJ El Deco ition U Submittal Fee $ Permit Fee $ • �g Scanning Fee $ ' co DCA Fee $ Technology Fee $ Training/Education Fee $ CCF $ CO/CC $ DBPR S Notary $ Structural Reviews $ P&Z Review $ Double Fee $ Bond $ 7 TOTAL FEE NOW DUE $ `L (Rev1sed04/05/2022) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City Zip Zip Application is hereby made to obtain a permit to do the work and Installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the jab site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a relnspection fee will be charged. Signature C OWNER or AGENT The foregoing instrumel was acknowledged before me this �dof 20�3 by SKLY0. who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: ¢rf CATHERINE A. DUFFIN MY COMMISSION # HH 089522 EXPIRES: May 14, 2025 APPROVED BY CONTRACTOR The foregoing instrume was acknowledged before me this 54day of 20 a 3 . by —7/om C s > 6 who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign:_ Print: Plans Examiner CATNER04EA.O�— p J' MVCOMMISSION# HH 089522 EXPIRES: May.., as Zoning (Revised04/05/2022) Structural Review Clerk OBENOUR ROOFING, SHEET METAL & SUPPLY CO. 9822 NE 2nd Ave. No 9 Miami Shores, FL 33138 (305)757-2612 JUL 18 2023 BY:— LX_ REV-07-23-1691 1245 NE 96 St. Answer to review comments: Our original permit submission showed this area in question as a "awning". When roofing inspector came on site, he requested that a revision be made to reflect this area as a "metal roof" I have complied with the inspectors request with this revision. This area in question in not part of the scope of our work nor is it part of our contract with the owner. No work to this area. (the area appears to be a TPO with a aluminum paint) Thank you. Jim Obenour, Jr ROOF ASSEMBkIES AND ROOFTOP STRUCTURES MSV PLANNING DEPARTMENT DATE: D� 2{er�zLJULOBY: �.?�?�� Florida Building Code7th Edition (2020) High -Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) CITY Master Permit No. F— 01,-Z3'-1 fs r Process No. Contractor's Name Z96E'AlOC/A 4v G�; no Py Job Address la 1(r '" � / l f f i rr� / f %f°Q es ROOF CATEGORY / ❑ Low Slope ❑ Mechanically Fastened Tile In Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF TYPE / ❑ New roof ❑ Repair ❑ Maintenance 9 Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) —� Steep Sloped Roof Area (SF) /'LL Total (SF) Ada Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. M Miami Shores V'Ila a Building DVFeder Zoning Dept. Date Building Dept. Subject to comp nce with all State and ,C.,, oyy.nty rules and regul tions. mitff t�- PerfV—iTI—?J�.1uR1 FLORIDA BUILDING CODE — BUILDING, 7th EDI 474 Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County Section D (Steep Sloped Roof System) Roof System Manufacturer: G2i1 N Product Control Number: A/ T 93.1 u fZ 2- Minimum Design Wind Pressures, From Applicable RAS 127 Table or Calculations: Zone1:1. '71- Zone 2e: �- S L Zone2n: 13.71 Zone 2r: 13- 72- Zone 3e: /3.7J- Zone 3r: a2f. ra Slope Range: Q>_ 2:12 to <_ 4:12 Roof Shape: QAII Hip Roof Deck Type: Roof Slope: G : 12 Ridge Ventilati n? A - Mean Roof Height: I B PQP� C9S4:12to56:12 0>6:12to512:12 ( 'able Roof or Partial Gable/Hip Roof b'.)V'Yd P14 Ok Underlayment Type: I 4,rfw A ZZ L yJ_3p Insulation: Fire Barrier: I 11,A Fastener Type & Spacing: 711;14 lcus/e o e Pack- ,GAGTfiG Cap Sheet Type: ,4-SfA b.2.yf --t� !ru Of , a f %//E �i%Ai�ffGO Cap Sheet Attachment: Roof Covering: 42A, Drip Edge Type & Size: /GOZ Coln�ev 3 � 3 G jl-�L I� oXy ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 7th Edition (2020) High -Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from M,. If the M, values are greater than or equal to the M, values, for each area of the roof, then the the attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127' (Zone 1:• -C? x R -ke = / - Mg: Ltk M Iy Product Approval M, /37 •.r (Zone 2e: s7 x + _ (�`� - Mg: t1 Ya= M28 9y Product Approval M r 37 f (Zone 2n: L l' fx x +?a = Mg: q-qr-- M, 13.7 2-- Product Approval M, 137• f (Zone 2r. 4/ x 2L ,;L9 = EY•L- - Mg: Y. yY= m. / 3. 75-Product Approval M, (Zone3e''I/ x2.-26 = 1- Mg, _tip Mr„!�•7Z Product Approval M, 137•J' (Zone 3r.-!2-0'x X +2s = "- Mg: y `rp= M � jU),- Product Approval M, V1` v1 Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval M, M, required Moment Resistance Mean Roof Height Roof Slope 15' 20' 25' 30' 2:12 34.4 36.5 38.2 39.7 ; ' 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 'Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based file systems use Method 3. Compare the values for P with the values for F,. If the P values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (Zone 1, xL_=_xw:= )-W:_xcosr_=F _ Product ApprovalF'_ (Zone 2e:_xL_=_xw:=_ I-W:_xcosr_=F._ Product Approval P (Zone 2n:_ x L = _ x w: = _ I - W: _ x cos r _ = F. _ Product Approval P (Zone 2r:_xL_=_xw:=--j-W.-xoosr_=FYI,_ Product ApprovalF'. (Zone 3e:_xL_=_xw:=_)-W:_xoosr_=Fq - Product Approval P (Zone 3r:_xL_=_xw:=--j-W:_x cos r_= Fa, _ Product Approval P. Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, Sr Fro applicable table In RAS 127 or by an engineering analy- m sis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope A Job Site Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity M Product Approval Attachment Resistance M, Product Approval Required Moment Resistance M Calculated Minimum Attachment Resistance P Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculatlons must be submitted to the building official at the time of permit application. FLORIDA BUILDING CODE - BUILDING, 7th EDITION (2020) 477 . ROOF ASSEMBLIES AND ROOFTOP STRUCTURES E1 151&8A.1 Roof rile systems, combining mechanically fastened file and mortar and/or adhesive, shall be acceptable. 151&8A.2 In an air permeable tile roofing system: (1) the length of each tile shall be not less than 12 inches (305 mm) and not greater than 21 inches (533 mm) and the exposed width of the tile shall be between 8.5 inches and 15 inches (216 min and 381 mm); (2) the maximum thickness of the nose (leading edge) of the tile shall not exceed 1.3 inches (33 min); and (3) mortar or adhesive set system shall have at least two-thirds of the tile free of mortar and/or adhesive contact. 1518.8.5 The proposed method of attachment for tile sys- tems which are considered to be air permeable, shall pro- vide sufficient attachment resistance (M.) (listed in tile product approval) to meet or exceed the moment of resis- tQfe (M,) as determined by following the procedures out- linfil in RAS 127. The aerodynamic multiplier (k) needed in PZAS 127 shall be part of the tile product approval and shiffi be derived from the following formulas fl direct deck application k = (0.156) x (b) x (1)2 f r batten application k= (0.144) x (b) x (1)2 b (in feet) = exposed width of the tiles 1(in feet) = length of tiles 1518.8.6 The proposed method of attachment for tile sys- tems which are not considered air permeable shall provide It minimum characteristic force (F) (listed in tile product ontrol approval) to meet or exceed the required uplift [resistance (F,) as determined by following the procedures outlined in RAS 127. 1518.8.7 Tile systems shall extend beyond the drip edge (not including the rake) not less than 3/, inch (19 min) but not more than 2 inches (51 mm). 1518.8.8 Reserved. 1518.8.9 Reserved. 1518.8.10 Mortar or adhesive set tiles applied at an incline from 6:12 up to and including 7:12 shall have the first course of tile (this applies to pan only on two-piece barrel tile) mechanically fastened with not less than one fastener per tie. As an alternate, the first course of file shall be applied in mortar over a single layer of minimum 20 gage galvanized wire mesh with openings of not less than '/_ inch (12.7 mm) or greater than l'/, inches (38 mm) with minimum exposure of 12 inches (305 mm) which is mechanically attached to the deck through the underlay- ment with approved fasteners and tin -cap when back -nail- ing the cap sheet. Additionally, for roof inclines of 6:12 up to and including 7:12, every third the of every fifth course, shall be mechanically fastened with not less than one fas- tener per tile. For roof inclines above 7:12, in addition to the mortar or adhesive, all tiles shall be mechanically fas- tened with not less than one fastener per tile. Apply approved flashing cement to seal all tile fastener penetra- tions, for all roof inclines. 1518.8.11 All tile systems shall be shingle lapped inter- locking and installed with the headlap as specified in the tile system product approval. In no case shall the mini- mum headlap be less than 2 inches (51 mm) for mortar or adhesive set tile, or less than 3 inches (76 mm) for mechanically set tile, unless restricted by product design. 1518.8.12 Where tiles are to be installed over an insulated roof deck, a suitable nailable substrate, in accordance with Sections 1520.5.6 and 1520.5.7 must be installed over the insulation prior to the installation of approved underlay- ment and tiles. 1518.8.13 For mortar or adhesive set tile, no more than two tiles shall be loose per roofing square [100 square feet (9.3 m')]. No loose file shall be adjacent to each other. 1518.9 Metal panels/ahmgles. Steel panels/shingles shall be a minimum of G-90 corrosion resistant, and shall be not less than 26 gage in thickness. Aluminum panels/shingles shall not be less than 0.025 inch (0.685 mm) thick. All other metal panel/shingle products shall be an equivalent weight All metal panel/shingle assemblies shall be capable of withstand- ing foot traffic without damage to the metal panels/shingles. Metal panels/sbingles shall have product approval for a com- plete metal system, which shall include the panel/shingle, underlayment and all related accessories to provide a com- plete waterproof system. 1518.9.1 All metal panels/shingles assemblies shall be tested in accordance with Section 1523 and TAS 125. 1518.9.2 The entire application method of all metal panel/ shingle systems shall be detailed in the product approval and RAS 133, as applicable. 1518.93 Metal shingles may be applied as a recover over a single layer of asphaltic shingles or smooth surface roof- ing, providing the deck is solid sheathed and in compli- ance with the provisions of this code, the existing prepared roof covering is in compliance with provisions of this code and the entire metal shingle system is applied as set forth in the product approval. 15189.4 Metal panel/shingle systems shall not extend more than 1 inch (25 mm) beyond the roof eave. 1518.95 All intersections shall be flashed in metal as pro- vided in Section 1517.6, RAS 111 and the roof assembly product approval. 1518.10 Wood shingles and shakes. All wood shingles and shakes shall be installed in accordance with RAS 130. Instal- lation of all wood shingles and shakes shall be limited to a roof mean height of 33 feet (10 m), unless otherwise specifi- cally noted in the product approval. 1518.10.1 All wood shingle/shake systems shall be tested in accordance with Section 1523. 1518.11 Building integrated photovoltaic roofing mod- ules/shingles. The installation of building integrated photo- voltaic roofing modules/shingles shall comply with the provisions of this section. FLORIDA BUILDING CODE - BUILDING, 7th EDITION (2020) 463 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH -VELOCITY HURRICANE ZONES —UNIFORM PERMIT APPLICATION Florida Building Code 7th Edition (2020) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT Baal IrATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2, 6,7 Wood Shingles and Shakes A,B,D 1,2,45,, 6,7 Other As Applicable ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable. RAS 127 or RAS 128 4, Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation FLORIDA BUILDING CODE - BUILDING, 7th EDITION (2020) 473. Section A (General Inrorman0ft) Mastet Pelmil ContcactoPSName Act Address /;' q r A)E 9'11 S r- Hr p'hr / Syr✓ ROOF CATEGORY / ❑ how Slope ❑ Mechanically Fastened Tile f3 Mortar/Adhesive Set Tiles Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF TYPE root ❑ Repair ❑ Maintenance ®' Reroofing ElRecovering ROOF SYSTEM INFORMATION Roof Area (SF)=_ Steep Sloped Roof Area (SF) Total (SF) -�_5/ n Section B (Roof Plan) Illustrate all levels and sectlone roof drains, scuppers, Overflow scuppers and overflow drains. Include dimes - and levels. Beady identify dims ions of elevated pressure zones and location of parapets. Y 3 f—�