Loading...
MC-09-23-2255Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit NO.: MC-09-23-2255 Permit Type: Mechanical - Residential Work Classification: A/C Replacement Permit Status: Approved Issue Date:09/14/2023 Expiration:03/11/2024 Location Address Parcel Number 13 NW 108TH ST, Miami Shores, FL 33168 1121360110310 Contacts ALEJANDRO ESTALELLA Owner CENTRAL COMFORTAIR CONDITIONING Contractor 13 NW 108 ST, MIAMI SHORES, FL 33168 ALEX ALBERT MARTINEZ aestalella@hotmail.com 12310 SW 129 CT, Miami, FL 33186 Business: 3055987575 centralcomfortacmiami@yahoo.com Description: EXACT AC CHANGE OUT Valuation: , $ 6,020.00 Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $4.20 DBPR Fee $3.26 DCA Fee $2.11 Education Surcharge $2.10 Permit Fee $160.70 Scanning Fee $15.00 Technology Fee $21.07 Total: $258.34 Payments Date Paid Amt Paid Total Fees $258.34 Credit Card 09/14/2023 $208.34 Credit Card 09/12/2023 $50.00 Amount Due: $0.00 7„2 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction arAlzoning. Futhermore, I authorize the above named contractor to do the work stated. �y-'l /1 /---j 191"4,"�'v 1 Authorized Signature: 0" / Applicant / Contractor / Agent Date September 14, 2023 Page 2 of 2 RECEIVED Miami Shores Village SEP 12 2023 Building Department BY: 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 2020" BUILDING Master Permit No. ,NjjC -09- 23-2ZSS PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION [-]RENEWAL ❑PLUMBING ❑■ MECHANICALPUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 13 NW 108TH ST City: Miami Shores Countv: Miami Dade Zip: Folio/Parcel#:11-2136-011-0310 Is the Building Historically Designated: Yes NO X Occupancy Type: RESID. Load: Construction Type: Flood Zone: BFE: FFE: N�'gS}�A �IbtLirl OWNER: Name (Fee Simple Titleholder):_Alt.-38NOYPhone#: ,,.,,,--13 NW 108TH ST City: MIAMI SHORES State: FL Tenant/Lessee Name: Phone#: Email: AESTALELLA@HOTMAIL.COM 33168 CONTRACTOR: Company Name: Central Comfort Air Conditioning Corporation Phone#: 305-598-7575 Address: 12310 SW 129th Ct City: Miami State: FL Zip: 33186 Qualifier Name: ALEX MARTINEZ Phone#: 305-598-7575 State Certification or Registration #: CAC057552 Certificate of Competency #: DESIGNER: Architect/Engineer: State: Zip: Value of Work for this Permit: $ %dzo • G U Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ■❑ Repair/Replace Description of work: EXACT AC CHANGE OUT Specify color of color thru Submittal Fee $ Permit Fee $ Scanning Fee $ Technology Fee Structural Reviews $ Radon Fee $ Training/Education Fee $ ❑ Demolition CCF $ CO/CC $ DBPR$ Notary: Double Fee $ Bond $ TOTAL FEE NOW DUE $ d . J (Rev1sed02/24/2014) L1 Bonding Company's Name (if applicable) Bonding Company's City S1 Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a ralacaaction fee will be charged. Signature V/ 11 Signature OWNER or AGENT The foregoing instrument was acknowledged before me this day of .20 . by who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: JPRHar6O APPROVED BY CONTRACTOR y The foregoing instrument was acknowledged before me this q T" day of %etia w . 20 Z3 by flex. M'X ili t , who is personally known to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: A 1 2 Plans Examiner Structural Review Commission k GG 922453 My Comm. Expires Oct 14, 2023 ad throuth National Notary Assn. as r�a••ra Zoning Clerk (Revised02/24/2014) Acknowledgment by Individual State of Florida County of Miami -Dade The foregoing instrument was acknowledged before me this 24th day of August , 20 23 , by means of ® physical presence or ❑ online notarization Alejandro Estalella (name of person acknowledging). ❑ Personally known to me ® Produced Identification Type of Identification Pr( Notary signature ► `� Notary name (typed or printed) Title (e.g., Notary Public) Notary Public Place Seal Here NWIG at* 9tetFlordl • MyemisalonEXPlrea121181M a t Db. GG 934rM For Bank Purposes Only Description of Attached Document Type or Title of Document Building Permit Application Document Date Signer(s) Other Than Named Above None Account Number (if applicable) N/A Number of Pages E © 2020 Wells Fargo Bank, N.A. All rights reserved. DSG5350FU595501 (Rev 05-05/21) OFFICE OF THE PROPERTY APPRAISER Summary Report PROPERTY Folio 11-2136-011-0310 13 NW 108 ST Property Address MIAMI SHORES, FL 33168-4310 ALEJANDRO ESTALELLA, NATASHA FLORIN Owner ESTALELLA 13 NW 108 ST Mailing Address MIAMI SHORES, FL 33168 Primary Zone 0800 SGL FAMILY - 1701-1900 SQ Primary Land 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Use Beds/Baths 3/3/0 /Half Floors 1 Living Units 1 Actual Area 1,662 Sq.Ft Living Area 1,611 Sq.Ft Adjusted Area 1,637 Sq.Ft Lot Size 9,225 Sq.Ft Year Built 1952 Year 2023 2022 2021 Land Value $350,777 $276,617 $229,154 Building Value $350,547 $354,771 $221,486 Extra Feature Value $19,053 $19,080 $19,080 Market Value Assessed Value Benefit Save Our Homes Cap Portability $720,377 $650,468 $469,720 $552,371 $536,283 $454,951 Type 2023 2022 2021 Assessment $168,006 $14,769 Reduction Assessment $114 185 Generated On: 09/05/2023 Year 2023 2022 2021 COUNTY Exemption Value $50,000 $50,000 $50.000 Taxable Value $502,371 $486,283 $404,951 SCHOOLBOARD Exemption Value $25,000 $25,000 $25,000 Taxable Value $527,371 5511,283 $429,951 CITY Exemption Value $50,000 $50,000 $50.000 Taxable Value $502,371 $486,283 $404,951 REGIONAL Exemption Value $50,000 $50,000 $50,000 Taxable Value $502,371 $486,283 $404,951 `ar SALESINFOBM Homestead Exemption $25,000 $25,000 $25,000 cos erati Previous OR OR Book - Second Sale Price Qualification Description Exemption $25,000 $25,000 $25,000 Homestead 04/12/2021 $810,000 32462-2454 Qual by exam of deed Note: Not all benefits are applicable to all Taxable Values (i.e. County, Corrective, tax or QCD; min School Board, City, Regional). 10/09/2018 $159,600 31173-4568 n id on 08/21/2017 $549,000 30672-4216 Qual by exam of deed DUNNINGS MIAMI SHORES EXT NO Financial inst or "In Lieu of 01/14/2015 $231,158 29486.4144 PB 52.33 Forclosure" stated LOT 15 BLK 214 LOT SIZE 75.000 X 123 OR 16625-2245 1294 1 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidad e.gov/info/disclaimer.asp ,o SEP 12 2023 BY:�� Certificate of Product Ratings AHRI Certified Reference Number: 208808192 Date : 09-05-2023 Model Status : Active AHRI Type; RCU-A-CB (Split System: Air -Cooled Condensing Unit, Coil with Blower) CITY Series: MERIT ML17XC1 SERIES Outdoor Unit Brand Name: LENNOX COPY Outdoor Unit Model Number (Condenser or Single Package) : ML17XC1-048-23W' Indoor Unit Model Number (Evaporator and/or Air Handler) : CBA25UH-048-230 Region: All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: On January 1, 2023, efficiency standards increased for central air conditioners. Beginning January 1, 2023, central air conditioners can only be Installed in region(s) for which they meet the new regional efficiency requirements. The manufacturer of this LENNOX product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 - 2017 with Addendum 1, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 47000 SEER: 15.10 EER (A2) - Single or High Stage (95F) : 12.20 Rated as follows in accordance with the latest edition of AHRI 210/240 —2023, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (AFeu) — Single or High Stage (95F), bluff : 45500 SEER2 : 14.70 EER2 (AFull) — Single or High Stage (95F) : 12.20 f"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced.'Production Stopped" Model Status am those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Rafings that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the previous (i.e. WAS) rating. The Department of Energy has published updated energy efficiency metrics for central air conditioners and heat pumps. This publication reflects both the 1987 metric (SEER) and the 2023 metric (SEER2). Efficiency requirements are published at 10 C.F.R. 430.32(c). Please refer to wwwAHRlneLorg for more information about updated energy efficiency metrics. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at wwwAhridirectoTy.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; ArMM entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the users individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information forthe model cited on this certificate can beverified at www.ahridirectory.org, click on "Verity Certificate' link ,.e make life Letter - and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which Is listed at bottom right. ©2023Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 133384164398152937 9/5/23, 3:36 PM Proposal Central Comfort Air Conditioning Corp. CALL US TODAY (305) 598-7575 Your Proposal Good ALEJANDRO ESTALELLA Address:13 NW 108th St Miami Shores, FL 33168 Phone: (305) 903-1010 Email: AESTALELLA@HOTMAIL.COM Consultation Code: ENGVSYHLD Date Presented: Aug 22, 2023 Date Accepted: Aug 22, 2023 Presented by: Howard Lizano Phone: (786) 759-5832 Email: hliz8888@gmail.com About Us Need a Fast & Reliable AC Solution in South Florida? It can feel hopeless, overwhelming and extremely uncomfortable when you find yourself stuck with AC problems. At Central Comfort Air Conditioning, we help South Florida homeowners and businesses find a fast, honest and reliable solution to what may seem like a hopeless situation. Whatever situation you may find yourself in... From broken AC, leaking AC, no cooling, or even replacing a unit, finding a reliable and fast solution can be timely, costly, and stressful. At Central Comfort Air Conditioning, we have the experience and expertise to help you resolve any situation you may find yourself in regarding your cooling and/or heating system in South Florida .At Central Comfort Air Conditioning, we've been servicing homes and commercial properties with top-notch air conditioning, heating, and indoor air quality products and services for the residents of Miami since 1997.We know how important it is for you and your family to always stay comfortable, no matter the time of year, or the temperature outside. We are always available to take your call and provide you with cost-effective, quality solutions for all your cooling and heating needs. Google. facebook ****f: W CAC057552 System Lennox ML17XC1 AC 4 Ton EQUIPMENT 2ITEMS https://app.oncellair.comMlhiew/accepted/2298af278b23cfl 64fee7cce99fdf2aaa03333014209211710528d346d8a769b/17251944264/2685606 1 /4 9/5/23, 3:36,PM Proposal INCLUDES Category: Condenser Name: Lennox, Merit Series ML17, 4.00 Ton, Air Conditioner Number: ML17XC1-048-230 Category: Fan Coil Name: Lennox, Merit Series, 4.00Ton, Air Handler Number: CBA25UH-048-230 Category:HVAC Add-Ons / Quantity: I Name: Lennox ECBA25-10CB HEATER KIT Number: WHATYOU'LLGET REcr'JVRD SEP 12 2023 By: 1 ITEMS 5 ITEMS Air Conditioner -Free A/C tune up with equipment install" TO BE DONE 6 MONTHS AFTER THE INSTALL DATE" An A/C tune-up keeps your air conditioning system in good working order. It includes Inspection of: coolant levels & pressure - wiring, contacts, capacitors & relays - evaporator coil - condensate drain- outdoor disconnect - condenser fan motor & blades - compressor at startup - Inspect & Clean Condenser - Check & adjust thermostat. When completed you will receive a recommendation for any other procedure needed to make your AC system run 100% efficiently. CENTRAL COMFORTTHREE (3) YEARS LABOR WARRANTY Every residential Air Conditioning unit comes with a Central Comfort Complimentary three (3) years laborwarrantyat no additional cost. This warranty covers labor and parts that break due to manufacturer defect if they have been properly installed and maintained by a licensed professional air conditioning contractor. Does not cover the expensive cost of laborfrom year Six (4) to Ten (10). Given the stress on your unit due to the brutal South Florida Heat and Humidity there is a verygood chance that something might go wrong with your unit in thefuture. Please ask ourtechnician about extended ten (10) labor warranty and our lowcost Monthly Maintenance Membership. PERMITS ARE NOT INCLUDED IN THIS PRICING, IF PERMITS ARE NEEDED THAN THEY ADDITIONAL Split unit installation Includes: - New Aluminum Stand - New Digital Thermostat- New Water Leak Prevention Sensor(s) - New Concrete Slab (if needed) - New Hurricane Approved Tie Downs - L Brackets - New Filter Dryer - One Free filter - All Materials are Included in the Price, if any additional materials are need Representative will notify if there is additional cost. WARRANTY-10 YRS Register Manufacturer Parts Warranty Registered Limited Warranty at no additional cost. This warranty covers parts that break because of manufacturer defect, but it does not cover the cost of labor (please ask about Labor Warranty Plans). Compressor, Outdoor Coil & Parts -Ten (10) Years. Indoor Coil and Parts - Ten (10) Years. Heater, Limited Warranty Period: Ten (10) Years https!//app.oncallair.00mt#tview/accepted/2298af278b23cfl64fee7cce99fdf2aaa03333014209211710528d346dBa769b/1725/944264/2685606 2/4 9/5/23, 3:36.PM INWt51 MtN I UL IAILS Proposal Sale Price $6,020.00 Total Investment $61,020.00 The Total Investment is the total cost of the goods and services described in this proposal FINANCING No Interest if Paid in Full in 18 Months. $334.45 / month FINANCING OPTION DISCLOSURE No Interest if Paid in Full within 18 Months with a one time Bank Fee of 4.89% of Total amount. (RECOMMENDED) Other financial options: 60 Month 0.00% interest with one time Bank Fee of 16.8% of Total amount Finance. 96 Months - 7.99% APR with equal monthly payments of 1.42% of the amount financed & one time Bank Fee of 6.55% of Total amount Finance. SIGNATURE TERMS AND CONDITIONS LIMITED WARRANTY: all materials, parts and equipment are warranted by manufacturers written warranty only. All labor performed by Central Comfort Air Conditioning is warranted for one year for all new unit installations, 90 days on replaced parts, ninety day for water leaks (water leaks due for lack of maintenance are not covered), or as indicated in writing. Central Comfort Air Conditioning will not be responsible for any property damage due to malfunctioning unit and/or water leak. Central Comfort Air Conditioning makes no other https:llapp.oncallair comt#/viewlaccepted/2298af278b23Cfl 64fee7Cce99fdf2aaaO3333014209211710528d346d8a769bll 725194426412685606 3/4 9/5/23, 3:36,PM Proposal warranties, express or implied, and its agents or technicians are not authorized to make and such warranties on behalf of Central Comfort Air Conditioning. RETENTION OF TITLE: Ownership and Title to and equipment or materials (the goods) furnished by Central Comfort Air Conditioning (the seller) shall remain vested in the seller and shall not pass to the buyer until the purchase price for the goods has been paid in full and received by the seller. Until title to the goods passes The seller shall have authority to retake, sell or otherwise deal with and/or dispose of all or any part of the Goods the seller and its agents and employees shall be entitled at any time and without the need to give notice, and/or without the need of court intervention, enter upon and property upon which the Goods or any part are stored or installed, or upon which the Seller reasonably believes them to be kept. The Buyer shall store or mark the Goods in a manner reasonable satisfactory to the Seller indicating that title to the Goods remain vested in the Seller, and the buyer shall be responsible for insuring the Goods to their full replacement value against damage from fire, water and theft at its own expense. Any amounts due from insurance claims or claims arising from tortuous act in the event of loss or destruction are herby assigned to the Seller, in this case at sellers request, buyer must provide seller with all the necessary information for collection and must allow an authorized representative to review the status of the assigned claims. Irrespective of whether title of the Goods remains vested in the Seller, risk in the Goods shall pass to the Buyer upon delivery. Until the secured claims are paid in full, the goods subject to retention of title can neither be pledged to third parties nor assigned. Buyer must immediately inform seller of any third -party access to sellers' property. LEGAL FEES: in the event Central Comfort Air Conditioning is required to bring any legal proceedings regarding the sale, delivery and service of the agreement, the buyer agrees to pay to all costs, including reasonable attorney fees, court costs and ancillary expenses incurred by Central Comfort Air Conditioning in enforcing its rights. RETURN POLICY: ALL SALES ARE FINAL. No refunds or exchanges will be given. An order may be cancelled only if done before the equipment or materials (the goods) have been delivered and installed. However, once an order has been successfully charged to a debit/credit card. All cancellations could be subject to a 20%fee. Furthermore, Buyer agrees to waive all rights to disputing the purchase of materials, equipment or services through American Express, Visa, Mastercard, and Discover internal dispute procedures. All requests for returns and or exchanges will be handled directly through Central Comfort Air Conditioning. PRICING IS VALID FOR 30 DAYS RECEIVE7D S€P 12 NO https:/Iapp.oncallair.comt#tviewlacceptedl2298af278b23cfl64fee7cce99fdf2aaa0333301420921171052Bd346d8a769b/I725/944264/2685606 4/4 &. j ENGINEERING `O^ ENGINEERINGExPRESS.COM 1 (866) 396-9999 CORP. OFFICE: 160 SW 12TH AVE SUITE 106, DEERFIELD BEACH, FL 33442 REPORT HOLDER: LENNOX INDUSTRIES LLfVNOX 2100 LAKE PARK BLVD RICHARDSON, TX 75080, USA 1-866-953-66091 WWW.LENNOX.COM SCOPE OF EVALUATION (compliance with the following codes): THIS IS A STRUCTURAL (WIND) PERFORMANCE EVALUATION ONLY. NO ELECTRICAL OR TEMPERATURE PERFORMANCE RATINGS OR CERTIFICATIONS ARE OFFERED OR IMPLIED HEREIN. This Product Evaluation Report is being Issued in accordance with the requirements of the Florida Building Code Seventh Edition (2020) per ASCE 7, FBC Building Ch. 16, FBC Building Sections 104.11 & 1522.2, FBC Existing Building Sections 707.1 & 707.2, FBC Mechanical 301.15, FBC Residential M1202.1 & M1301.1, FS 471.025, and Broward County Administrative Provisions 107.3.4. The product noted on this report has been tested and/or evaluated as summarized herein. SUBSTANTIATING DATA: • Product Evaluation Documents Substantiating documentation has been submitted to provide this product evaluation and is summarized in the sections below. • Structural Engineering Calculations Structural engineering calculations have been prepared which evaluate the product based on rational analysis to qualify the following design criteria: • Maximum unit dimensions and weight range certified herein • Maximum allowable lateral and uplift pressures certified herein • Tie -down dip/strap configuration and anchor spacing • Anchor capacity for various substrates Calculation summary is included in this product evaluation. NOTE: No 33% increase in allowable stress has been used in the design of this product INSTALLATION: The product(s) listed above shall be Installed in strict compliance with this product evaluation & manufacturer -provided enclosure model specifications. The product components shall be of the material specified in the manufacturer - provided product specifications. All fasteners and anchors shall be installed in accordance with the applicable provisions specified herein in addition to the anchor/fastener manufacturers' published installation instructions. LIMITATIONS & CONDITIONS OF USE: Use of this product shall be in accordance with this product evaluation as noted herein. The supporting host structure shall be designed to resist all superimposed loads as determined by others on a site -specific basis as required by the Authority Having Jurisdiction. Host structure conditions which are not accounted for in these products' respective anchor schedule shall be designed on a site -specific basis by a registered Professional Engineer. No evaluation is offered for the host supporting structure by use of this document, adjustment factors noted herein and the applicable codes must be considered where applicable. All supporting components which are permanently installed shall be protected against corrosion, contamination, and other damage at all times. UNIT CASING MATERIALS: Unit casing materials and fasteners are dependent on the Product Line. See next page for further descriptions. TERMINOLOGY: See herein for definitions of abbreviations used in this evaluation. Technical Evaluation Report DIVISION: 23 08 00 - COMMISSIONING OF HVAC FL 37637.2 THIS DOCUMENT CONTAINS (15) PAGES. Florida Building Code Seventh Edition (2020) NOTE: THE GRAPHICAL DEPICTIONS IN THIS REPORT ARE FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER IN APPEARANCE. OPTIONS: This evaluation is valid for all Lennox Merit, Elite, and Dave Lennox Signature Collection units described herein. Any structural changes outside of the design as described herein would void this certification. STRUCTURAL PERFORMANCE: Models referenced herein are subject to the following design limitations: Maximum Rated Wind Pressures*: t 148 psf Lateral, 117 psf Uplift - Required design pressures shall be determined according to the guide shown In the Appendix (see last page of this report) or on a site -specific basis in accordance with ASCE 7 and applicable sections of the building code(s) being referenced in accordance with ASO methodology. - Required design pressures shall be less than or equal to the maximum pressures listed herein. -'Maximum Rated Wind Pressures indicate the maximum pressures that all units listed herein are approved for. Valid for at -grade and rooftop applications. See limitations herein. - Valid inside and outside the High -Velocity Hurricane Zone (HVHZ) - Slte-specific wind analysis may produce alternate Ilmltations provided maximum rated wind pressures stated herein are not exceeded. VISIT ECALC.10/32211 r: FOR SITE -SPECIFIC DEVIATIONS & MORE ■ rl I ■ INFORMATION ABOUT THIS DOCUMENT �IL I l OR SCAN THE OR CODE TO THE RIGHT > ,,� VISIT ENGINEERINGEXPRESS.COM/STORE FOR ADDIMONAL PLANS, REPORTS & RESOURCES 91 F. _ J ENGINEER SIGNATURE AND SEAL Digitally signed by Frank Bennardo Date: 2021.04.15 15:25:59-04'00' April 15, 2021 Frank Bennardo, P.E., SECB ENGINEERING EXPRESS® FL PE #0046549 FLCA #9885 Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering Expre: TER-20-32211 UNIT CASING MATERIALS, CONTINUED Product Line I Unit Casing Materials I Fastener Information Unit Base: 18 GA, Fy = 15 ksi min. galv. EDDS steel Top Panel: 18 GA, Fy = 25 ksi min. galv. DDS steel REC EIVEn Control Box: 18 Ga, Fy = 30 ksi min. galv. CS Type B steel SEP 12 2023 Control Box Cover, Control Box Bottom (4 Sided Unit): 13y' Merit Series 18 Ga, Fy = 20 ksi min. gals. DDS steel Corner Posts, Mullion, Piping Panel: 24 Ga, Fy = 30 ksi min. galv. CS Type B steel Louvered Panels, Coil Guard: 24 GA, Fy = 30 ksi min. galv. CS Type B steel Unit Base, Top Panel: 18 GA, Fy = 15 ksi min. galv. EDDS steel Control Box: 18 Ga, Fy = 30 ksi min, galv. CS Type B steel Unit casing components are fastened together Control Box Cover: 20 Ga, Fy = 20 ksi min. galv. DDS steel with #8-18, 1575 lb min. tensile strength Control Box Bottom (4 Sided Unit): 20 Ga, Fy = 25 ksi min. galv. (ultimate) and 1000 lb Elite Series CS Type C steel min. shear strength (ultimate) SMS. Corner Posts, Mullion, Piping Panel: 20 Ga, Fy = 30 ksi min. galv. CS Type B steel Louvered Panels, Coil Guard: 22 GA, Fy = 30 ksi min. galv. CS Type B steel Unit Base, Top Panel: 18 GA, Fy =15 ksi min. gals. EDDS steel Control Box, Control Box Cover: 18 Ga, Fy = 30 ksi min. galv. CS Dave Lennox Type B steel Signature Corner Posts, Mullion, Piping Panel: 20 Ga, Fy = 30 ksi min. Collection gals. CS Type B steel Louvered Panels, Coil Guard: 22 GA, Fy = 30 ksi min. galv. CS Type B steel NOTE: See manufacturer for more information on unit construction. CORP. OFC: 160 SW 12r AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 2 of 15 (954)354-0660 1 (866)396-9999 1 TEAM@ENGINEERINGEXPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering Express' I TER-20-32211 MODEL INFORMATION See Next Pages for Additional Models / Product Lines Product Line: Merit Series Model Number Coil Protection Unit Width (in) Unit Depth (in) Unit Height (in) ML14XC1-018* Louver 24.25 24.25 29.25 ML14XC1S018* 14ACX-018* 14ACXS018* 16ACX-024* 16HPX-024* Louver 24.25 24.25 33.25 M L14XC1-024* Louver 28.25 28.25 29.25 M L14XC1-024* ML14XC1-036* ML14XClS036* 14ACX-024* 14ACXS024* 16ACX-036* ML14XC1-036* Louver 28.25 28.25 33.25 M L14XClS036* ML16XP1-024* ML16XP1-030* 14ACX-042 * 14ACXSO42* M L14XC1-030* Louver 28.25 28.25 37.25 M L14XClS030* ML14XC1-041* ML14XC1-042* ML14XC1SO42* M L14XC1-048* ML14XP1-036* ML14XP1-036* ML14XP1-036* 14ACX-030* 14ACXS030* 14ACX-036* 14ACXS036* 14ACX-041* 14ACX-048* 16ACX-048* ML14XP1-018* Louver 28.25 28.25 43.25 ML14XP1-024* ML14XP1-030* ML16XP1-018* Product Line: Merit Series Model Number Coil Protection Unit Width (in) Unit Depth (in) Unit Height (in) M L14XC1-047* Louver 32.25 32.25 33.25 ML16XP1-036* 16H PX-036* 16HPX-048* 14ACX-047* 14ACX-060* ML14XP1-042* Louver 32.25 32.25 37.25 ML14XP1-042* ML14XP1-042* ML14XP1-048* ML14XP1-048* ML14XP1-048* 14ACX-059* M L14XC1-059* Louver 32.25 32.25 43.25 M L14XC1-060* ML14XP1-060* ML14XP1-060* ML14XP1-060* ML16XP1-042* M L16XP1-048* M L16XP1-060* 16ACX-060* 16H PX-060* TSA036S* Wire Guard 24.25 24.25 29.25 TSA036S* TSA036S* TSA036S* TPA036S* Wire Guard 24.25 24.25 33.25 TPA036S* TSA042S* Wire Guard 28.25 28.25 29.25 TSA042S* TSA042S* TSA042S* TPA036H* TPA036H* MODEL INFORMATION NOTES: All unit net weights shall be between 100 lb and 375 lb. Model numbers, dimensions, and weights listed herein are based on information provided by the client. Please contact Report Holder and/or manufacturer for more information. Louver directions may be horizontal of vertical. See herein for unit views and definitions of dimensions. Model number characters following the asterisk (*) do not pertain to this structural certification and may be any combination of numbers or characters. See next page for link to full list of model numbers without asterisks. CORP. OFC: 160 SW 12111 AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 3 of 15 (954) 354-0660 1 (866) 396-9999 1 TEAM@ENGINEERINGEXPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering Expres- TER-20-32211 MODEL INFORMATION, CONTINUED See Previous / Next Page for Additional Models / Product Lines Product Line: Merit Series Model Number Coil Protection Unit Width (in) Unit Depth (in) Unit Height (in) TSA060S* Louver 28.25 28.25 33.25 TSA060S* TSA060S* TSA060S* TPA036H* TPA036H` TSA048S* Louver 28.25 28.25 37.25 TSA048S* TSA048S* TSA048S* TPA042H* Louver 32.25 32.25 37.35 TPA042H* TPA042H* TPA042H* TPA048H* TPAO48H* TPAO48H* TPA048H* TPAO60H* Louver 32.25 32.25 43.25 TPAO60H* TPAO60H* TPA06DH* MODEL INFORMATION NOTES: All unit net weights shall be between 100 lb and 375 lb. Model numbers, dimensions, and weights listed herein are based on Information provided by the client. Please contact Report Holder and/or manufacturer for more information. Louver directions may be horizontal of vertical. See herein for unit views and definitions of dimensions. Model number characters following the asterisk (•) do not pertain to this structural certification and may be any combination of numbers or characters. VISIT ECALC.10/32211 i FOR A LIST OF APPROVED MODEL NUMBERS Ali ray STATED IN FULL (NO ASTERISKS), OR SCAN �•i 17 THE OR CODE TO THE RIGHT > J . ❑ r Product Line: Dave Lennox Signature Collection Model Number coil Protection Unit Width (in) Unit Depth (in) Unit Height (in) XP21-024* Louver 39.5 35.5 37 XP21-036* XP25-024* XP25-036* SL18XP1-024* SL18XP1-030* SL25XPV-024* SL25XPV-036* SL18XC1-030* Louver 39.5 35.5 41 SL18XC1-036* SL18XC1-042* SL18XP1-036* SL18XP1-042* SL18XC1-024* Louver 39.5 35.5 47 SL18XC1-048* SL18XC1-060* SL18XP1-048* SL18XP1-060* SL25XPV-048* SL25XPV-060* SL28XCV-024* SL28XCV-036* SL28XCV-048* SL28XCV-060* XC21-024* XC21-036* XC21-048* XC21-060* XP21-048* XP21-060* xc25-024* XC25-036* XC25-048* XC25-060* XP25-048* XP25-060* CORP. OFC: 160 SW 12T AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 4 of 15 (954)354-0660 1 (866)396-9999 1 TEAM@ENGINEERINGEXPRESS.COM I ENGINEERINGEXPRESS.COM Lennox .Merit, Elite, Dave Lennox Signature Collection Engineering Express° I TER-20-32211 • MODEL INFORMATION, CONTINUED See Previous Pages for Additional Models / Product Lines Product Line: Elite Series Model Number coil Protection Unit Width (in) Unit Depth (in) Unit Height (in) EL16XC1-018* Louver 28 27 31 XP16-024* Louver 28 27 35 ELI8XCV-024* ELI8XCVS024* ELI8XCV-036* ELI8XCVS036* ELI8XPV-024* ELI8XPV-036* EL16XC1-024* Louver 35 30.5 31 EL16XC1-036* EL16XC1S036* XC16-036* XC16SO36* SSB036H* SSB036H* EL16XC1-036* Louver 35 30.5 35 EL16XC1S036* EL16XC1-041* EL15XP1-018* EL15XP1-024* EL15XP1-030* EL16XP1-024* EL16XP1-030* XC16-048* Louver 35 30.5 39 XC16SO48* EL16XC1-030* EL16XC1-042* EL16XC1-048* SSB048H* SSB048H* EL15XP1-036* MODEL INFORMATION NOTES: All unit net weights shall be between 100 lb and 375 lb. Model numbers, dimensions, and weights listed herein are based on information provided by the client. Please contact Report Holder and/or manufacturer for more information. Louver directions may be horizontal of vertical. See herein for unit views and definitions of dimensions. Model number characters following the asterisk (*) do not pertain to this structural certification and may be any combination of numbers or characters. See previous page for link to full list of model numbers without asterisks. Product Line: Elite Series Model Number Coil Protection Unit Width (in) Unit Depth (in) Unit Height (in) XC16-024* Louver 35 30.5 45 XC16SO24* EL16XP1-018* ELI8XCV-048* ELI8XCVSO48* ELI8XCVS060* ELI8XPV-048* ELI8XPV-060* EL16XC1-047* Louver 39.5 35.5 35 EL16XC1-060* XP16-036* SP13036H* XP16-048* SPB048H* EL16XP1-036* XC20-024* Louver 39.5 35.5 39 XC20-036* EL15XP1-042* EL15XP1-048* XP20-024* XP20-036* XC16-060* Louver 39.5 35.5 45 XC16SO60* SSB060H* SSB060H* XP16-060* SPB060H* EL15XP1-060* EL16XP1-042* EL16XP1-048* EL16XP1-060* ELI8XCV-060* XC20-048* XC20-060* XP20-048* XP20-060* CORP. OFC: 160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 5 of 15 (954) 354-0660 1 (866) 396-9999 1 TEAM@ENGINEERINGEXPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering TER-20-32211 CABINET TYPES, VIEWS, & DIMENSIONS LOUVER UNITS: MERIT SERIES WIDTH lA FRONT VIEW_ a SIDE VIEW -_ RIGHT 6 SCALE: NTS 6 SCALE: NTS NOTE: See next page for "Wire Guard Units: Merit Series" cabinet type DEPTH —� O 3 lc TOP VIEW 6 SCALE: NTS lD ISOMETRIC VIEW 6 SCALE: NTS 1A 6 NOTE: Unit depictions in Details 1A through iD are for illustrative purposes only. Actual units may vary slightly in appearance. Louvers on wall panels are not shown. Louver direction may be horizontal or vertical. This Cabinet Type is applicable for Merit Senes - Louver units (see "Model Information" on pages 3 through 5 for model designations). LOUVER UNITS: ELITE SERIES DEPTH -- DEPTH 2A FRONT VIEW 21 SIDE VIEW - RIGHT 2c TOP VIEW 6 SCALE: NTS 6 SCALE: NTS 6 SCALE: NTS 21 ISOMETRIC VIEW 6 SCALE: NTS 2A _I 6 NOTE: Unit depictions in Details 2A through 2D are for illustrative purposes only. Actual units may vary slightly in appearance. Louvers on wall panels are not shown. Louver direction may be horizontal or vertical. This Cabinet Type is applicable for Elite Senes - Louver units (see "Model Information" on pages 3 through 5 for model designations). LOUVER UNITS: DAVE LENNOX SIGNATURE COLLECTION • WIDTH --- -DEPTH -- S G / ;/. 3A_ 6 3 A. 6 k-FRONT VIEW 3B,, SIDE VIEW - RIGHT i33 TOP VIEW _ _ _3p . ISOMETRIC VIEW 6 SCALE: NTS SCALE: ITM 6 SCALE: NTS 6, SCALE: NTS NOTE: Unit depictions in Details 3A through 3D are for illustrative purposes only. Actual units may vary slightly in appearance. Louvers on wall panels are not shown. Louver direction may be horizontal or vertical. This Cabinet Type is applicable for Merit Series - Louver units (see 'Model Information' on pages 3 through 5 for model designations). CORP. OFC: 160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 6 of 15 (954) 354-0660 1 (866)396-9999 1 TEAM@ENGINEER-INGExPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering I TER-20-32211 CABINET TYPES, VIEWS, & DIMENSIONS, CONTINUED WIRE GUARD UNITS: MERIT SERIES aA FRONT VIEW cab SIDE VIEW - RIGHT sw E: NTs scaLE: Nrs DEPTH L4cP VIEW TNrs SEP 12 2023 BY: v aD ISOMETRIC VIEW � scams: Nrs NOTE: Unit depictions in Details 4A through 40 are for illustrative purposes only. Actual units may vary slightly in appearance. This Cabinet Type is applicable for Mart Series - Wire Guard units (see "Model Information" on pages 3 through 5 for model designations). TERMINOLOGY, CONTINUED The following abbreviations may appear in this report: "ASCE" for "American Society of Civil Engineers", "ASD" for 'Allowable Stress Design", "FBC" for "Florida Building Code', "FLCA" for "Florida Certificate of Authorization", "FMC" for "Florida Mechanical Code", "HVAC" for "heating, ventilation, and air conditioning", "in" for "inch", "lb" for "pound (force) "max." for "maximum", "min." for "minimum", "NTS° for "not to scale', "OD" for "outer diameter", "PE" for 'Professional Engineer', "SAE" for °Society of Automotive Engineering", "SECB" for "Structural Engineering Certification Board",'SMS" for "sheet metal screws", "SS" for "stainless steel", 'TER" for "Technical Evaluation Report" "typ' for "typical", "U.N.0.' for "unless noted otherwise", "w1c" for 'without", W for "number', and "0' for "diameter'. For additional abbreviation/terminology darifications, please contact this office. REMAINDER OF PAGE IS INTENTIONALLY LEFT BLANK CORP. OFc: 160 SW 12TM AVENUE SUITE 106, DEERFIELD BEACH, FLGRIDA 33442 Page 7 of 15 (954)354-0660 1 (866)396-9999 1 TEAM@ENGINEERINGEXPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering Express® I TER-20-32211 PRODUCT INSTALLATION TIE -DOWN CLIP SCHEDULE Cabinet Type Wind Pressure Lateral (Uplift) # of Tie -Down Clips Required Louver ± 67 psf 0 s 4 ± 90 psf 72 s 8 ± 120 psf 95 s 8 ± 148 psf 117 s 8 Wire Guard ± 67 psf 0 pso 8 ± 90 psf 72 s 8 ± 120 psf 95 s 8 ± 148 psf 117 s 8 TIE -DOWN CLIP SCHEDULE NOTES: Louver Units: For at -grade pressures up to ± 67 psf lateral (0 psf uplift), position (1) tie -down clip per comer of unit, (4) total. For rooftop pressures up to ± 148 psi lateral (117 psf uplift), position (2) tie -down clips per comer of unit, (8) total. See tie -down layouts on the following pages.Tie-down clip shall sit flush on host structure and flush against unit comer post. Fasten be -down clip to comer post with (4) #10 SS316 self -drilling screws with 0.395" min. OD washers, typ. Utilize any (4) slots that have flush, solid contact with unit comer post, (1) screw per slot, typ. (See Detail 1/8). Ensure all screws fully engage with unit comer posts. Fasten tie -down clips to host structure using (1) anchor per tie -down clip per the "Anchor Schedule to Host Structure" table shown herein. WARNING: HIGH PRESSURE REFRIGERANT HAZARD ' Exercise caution while installing screws into the unit to avoid piercing refrigerant lines behind unit base / comer posts. Refrigerant fluid is under high pressure. Wire Guard Units: Position (2) tie -down clips per comer of unit, (8) total (see tie -down installation layout on the following pages). Provide 4" min. spacing between neighboring fie -down clips. Each tie -down clip shall sit flush on host structure and flush against vertical face of unit base (See Detail 2/8). Fasten tie -down clip to base rail with (2) #10 SS316 self-drilfing screws with 0.395" min. OD washers, typ. Utilize the (2) slots that make flush contact with vertical face of unit base, (1) screw per slot, typ. (See Detail 2/8). Ensure all screws fully engage with solid sections of unit base (do not position tie -down clips where holes/slots in the base rail interfere with screw connections). Fasten each tie -down clip to host structure using (1) anchor per the "Anchor Schedule to Host Structure" table shown herein. ANCHOR SCHEDULE TO HOST STRUCTURE Wind Pressure Lateral (Uplift) 3000 psi min. Concrete 1/8" min. thick Fy = 36 ksi min. Steel 1/8" min. thick 6061-T6 Aluminum ± 67 psf 0psf) A N/A N/A ± 90 psf 72psf) N/A B B ± 120 psf 95psf) N/A B B ± 148 psf 117 s N/A B B ANCHOR SCHEDULE TO HOST STRUCTURE NOTES: All host structures described in the anchor schedule are by others. Anchors shall be selected per site -specific wind pressures and host structure. Wind pressures up to ± 67 psf lateral (0 psf uplift) and below shall use the anchor specified in the ± 67 psf lateral (0 psf uplift) tier. Site -specific wind pressures that fall in-between pressure tiers shall use the anchor specified by the higher pressure tier. MIAMI TECH 1 TIE -DOWN CLIP O Miami Tech CUTD 1" wide and 8" tall ASTM 4� p A653 galvanized steel, 0.07" min. thick. O Fasten clip to host structure per the "Anchor (� O Schedule to Host Structure" table and notes. Fasten clip to unit base rail per the "Tie -Down O Clip Schedule" table and notes. O Q Miami Tech Kit #'s: LACUTD8KG - At -Grade or Slab Mounts LACUTD8KR - Rooftop or Rail Mounts 1 UNIT CORNER POST, TYP. UNIT WALL PANELS WITH O LOUVERS, O TYP. 0� UNIT BASE, U TYP 0 HOST STRUCTURE 0 SUBSTRATE(SEE ANCHOR o SCHEDULE TO 0 HOST STRUCTURE 0 HEREIN) ANCHOR (SEE ANCHOR 010 SCREW PER SCHEDULE TO HOST DESCRIPTION STRUCTURE HERBN) HEREIN, TYP. TIE -DOWN CLIP ATTACHMENT 1 TO LOUVER UNITS, TYP. 8 SCALE: NTS ISOMETRIC VIEW VERTICAL 1 WIRE FACE OF GUARD, UNIT BASE, TYP. TYP. INWARD - SECTION SLOPING SECTION OF UNIT BASE, TYP. HOST STRUCTURE SUBSTRATE (SEE ANCHOR SCHEDULE TO HOST STRUCTURE HEREIN) ANCHOR (SEE ANCHOR SCHEDULE TO HOST STRUCTURE HEREIN) Anchor Schedule to Host Structure Key: A: 1/4" 0 DeWalt UltraCon+ or equivalent with 1" min. OD washer, 1.75" embedment, and 3" min. edge distance from any edge of concrete, typ. B: 1/4" 0 SAE GR. 5 or SS Thru Bolt with 5/8" min. OD washers top and bottom, typ. Provide 1/2" min. edge distance between Thru Bolt and any edge of substrate, typ. NIA: Not applicable. 00 SCREWS PER DESCRIPTION HEREIN, TYP. TIE -DOWN CLIP ATTACHMENT 2 TO WIRE GUARD UNITS, TYP. 8 SCALE: NTS ISOMETRIC VIEW CORP. OFC: 160 SW 12T" AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 8 of 15 (954) 354-0660 1 (866) 396-9999 1 TEAM@ENGlNEERINGExPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering TER-20-32211 PRODUCT INSTALLATION CONTINUED TIE -DOWN STRAP SCHEDULE Cabinet Type Wind Pressure Lateral (Uplift) #of Straps Louver t 67 psf 0 sf 0 3 90 psf 72 sf 2 3120 psf 95 s 2 t 148 psf 117 2 Wire Guard t 67 psf D 0 t 90 psf 72 psfl 2 S 120 psf 95 2 t 148 psf 117 sf 2 TIE -DOWN STRAP SCHEDULE NOTES: 1. Tie -down straps are required for rooftop applicators. 2. Tie -down straps shall be 1" min. wide, 22 GA (0.03') min. thick, Fy = 30 ksi min. galvanized steel straps. 3. Tie -down straps shall be wrapped around unit and roof stand rail per Detail 1/9. and each tie -down strap shall be tightened to 50 Ib. 4. (Optional) Neoprene pads may be placed in-between unit and strap to protect the unit from damage. :�4]Icola C6Af_AW_i01111]:Ul4fdIIll For installation conditions where both L ) The wit in question is adequalely supported by the roof stand rails, and it. I The fie -dawn Gip and strap requirements are satisfied using only the root stand rails, It is permissible to forgo the roof frame specified herein. For all other conditions, a roof frame shall be be implemented per the specifications herein, or site -specific engineering is required. Support angles per NOA #17-1218.02 are included in Miami Tech Kit #LACUTD8KR. ATTACH TOGETHER FRAME USING (2) ��' 0 SS THRUSOLTS ROOF STAND OREOUNALENTPERCORNER r RAIL m. PROVIDE LOCK NUTAND I'OD OTHERE WASHER TOP AND BOTTOM. TYP. PROVIDE Y,- MIN. SPACING AND Y- EDGE DISTANCE MIN. FROM EDGE OF MEMBER, TYP. 3`X3'A'S0SI46 ALUMINUM ANGLES FOR ASSEMBLING FRAME ATTACH FRAME TO ROOF STAND RAILS USING (2) O SS THRU BOLTSOR EQUIVALENT PER CORNER. PROVIDE LOCK NUT AND 1.OD WASHER TOP AND BOTTOM, TYP. PROVIDE YI' MIN. SPACING AND W EDGE DISTANCE MIN. FROM EDGE OF MEMBER. TYP ROOFFRAME 2 , TYPICAL CONNECTIONS 9 SCALE: N75 PLAN VIEW TIE -DOWN STRAP ALUMINUM OR STEEL MEMBER, MIN. Y THICK (2) 014 EMS AT EACH STRAP END TO VERTICAL FACE OF ALUMINUM OR STEEL MEMBER (2) 014 EMS AT EACH STRAP END TO HORIZONTAL FACE OF ALUMINUM OR STEEL MEMBER TIE -DOWN STRAP ATTACHMENT TO HOST 9 SCALE: NTS SECTION VIEW NOTE: For Detail 3/9, the unit depicted is for illustrative purposes only and may be any of the cabinet types listed herein. Lowers on panels are not shown. See tie -down layouts on the next page. UNIT MOUNT ON ROOF STAND AND FRAME SCALE: NrS ISOMETRIC VIEW CORP. OFC: 160 SW 12T" AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 9 of 15 (954) 354-0660 1 (866) 396-9999 1 TEAM(•l0 ENGINEERINGEXPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering I TER-20-32211 TIE -DOWN CLIP & STRAP LAYOUTS MIN. EDGE TIE -DOWN CLIP, ANCHORS PER DISTANCE RESPECTIVE SCHEDULES, TYP. PER ANCHOR ONLY (1) CLIP PER CORNER IS SCHEDULE, REQUIRED FOR LOUVER UNITS. TYP. I I SEE SCHEDULE HEREIN. 3000 psi MIN. CONCRETE (BY OTHERS) Q1 AT -GRADE LAYOUT 10 SCALE: NTS PLAN VIEW SEP 12 zoj (2)TIE-DOWN STRAPS PER SCHEOUBl i ; MAY GO ALTERNATE DIRECTION AS FIELD CON D. DICTATE. SEE SEPARATE 3'k3"Op DETAIL FOR STRAP ATTACHMENT. ALUMINUM ANGLE 7 TIE -DOWN CLIP, ANCHORS FRAN PER RESPECTIVE SCHEDULES, TYP. SEE HEREIN. O . ��ROOF STAND RAILS (PER SEPARATE ENGINEERING) a) ROOFTOP LAYOUT 10 SCALE: NTS PLAN VIEW NOTE: The units depicted on this page are for illustrative NOTE: Units may be positioned on roof stand rails along purposes only and may be any of the cabinet types listed the unit depth or unit width as long as specifications herein. stated herein are satisfied. Miami Tech Kit IYs: LACUTDBKG - At -Grade or Slab Mounts LACUTD8KR - Rooftop or Rail Mounts CORP. OFC: 160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 10 Of 15 (954)354-0660 1 (866)396-9999 1 TEAM@ENGINEERINGEXPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering Express° I TER-20-32211 `PANEL DESIGNATIONS: LOUVER UNITS, MERIT SERIES 1 FRONT ISOMETRIC VIEW BACK ISOMETRIC VIEW 11 SCALE:NTS 11 SCALE:NTS NOTE;: The unit depictions In Details 1/11 and 2/11 are for illustrative purposes only. Actual units may vary slightly in appearance. Louvers on Panel Ns (Wall Panels) are not shown. Louver direction may be horizontal or vertical. Circled regions above illustrate additional screw locations per the additional screw directives below. This page applies to Merit Series louver units; see pages 3 through 7 for cabinet type classifications. PANEL INTEGRITY SUMMARY: LOUVER UNITS, MERIT SERIES Up to f 67 psf Lateral & 53 psf Uplift Wind Pressures Panel Additional Designation Screws Additional Screws Directive Required Top 0 No additional screws required for Panel #1 Top Panel #1. Panel A 0 No additional screws required for (Wall Panel) Panel A's (Wall Panels). Panel B (Comer 0 No additional screws required for Panel B's Post) (Corner Posts). Panel C (Control 0 No additional screws required for Panel C Box Cover) (Control Box Cover). Panel D 0 No additional screws required for Panel D. Panel E 0 No additional screws required for Panel E. NO ADDITIONAL SCREWS REQUIRED Up to 148 psf Lateral & 217 psf Uplift Wind Pressures Panel Additional Designation Screws Additional Screws Directive Required Top No additional screws required for Panel #1 o Top Panel #1. Panel A Install (4) screws at bottom of each panel into (Wall Panel) 4 Unit Base. Note: (4) per Panel A, (16) screws total. Panel B (Comer 0 No additional screws required for Panel B Post) (Corner Posts). Panel C (Control 0 No additional screws required for Panel C Box Cover) (Control Box Cover). Panel D 0 No additional screws required for Panel D. Panel E 0 No additional screws required for Panel E. (16) ADDITIONAL SCREWS REQUIRED IN TOTAL Panel Integrity Summary Notes: WARNING: HIGH PRESSURE REFRIGERANT HAZARD No additional screws are required for Exercise caution while installing additional screws into the Wind pressures up to :t 67 psf lateral & 53 psf uplift unit to avoid piercing refrigerant lines behind panels. Calculations were performed according to the information provided • Refrigerant fluid is under high pressure. by the client for a worst -case unit (which was determined by this office to be a (39.5" W x 35.5" D x 47" H unit). Panels were assigned various porosities depending on the ratio of louver area to total panel area, for tension and shear calculation purposes. Screw quantities were checked to reinforce unit panels as needed. Additional screws shall be #S min. diameter SAE GR. 2 or stronger SMS. They shall be positioned according to the "Additional Screws Directives" in the tables above and Details 1/11 and 2/11. Provide 1" min. spacing between neighboring screws (existing or additional). Distribute additional screws evenly between left and right sides of the panel U.N.O. Validate that each additional screw joins the panel to the 24 GA min. thick steel member. Screw sizes, quantities on panels, and panel characteristics are according to client's description. 1000 hours of ASTM B117 are required with zero red rust for all additional screws. CORP. OFC: 160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 11 of 15 (954) 354-0660 1 (866) 396-9999 1 TEAM@ENGINEERINGExPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering T- I TER-20-32211 PANEL DESIGNATIONS: WIRE GUARD UNITS, MERIT SERIES i FRONT ISOMETRIC VIEW \12 SCALE: WS 2 BACK ISOMETRIC VIEW 12 / SCALE: NTS Pv_ NOTE: The unit depictions in Details 1112 and 2/12 are for illustrative purposes only. Actual units may vary slightly in appearance.This page applies to Merit Series wive guard units; see pages 3 through 7 for cabinet type classifications. PANEL INTEGRITY SUMMARY: WIRE GUARD UNITS, MERIT SERIES Up to 1149 psf Lateral & 117 psi Uplift Wind Pressures Panel Additional Designation Screws Additional Screws Directive Required Top No additional screws required for Panel q1 0 Top Panel g1. Panel C (Control 0 No additional screws required for Panel C Box Cover) (Control Box Cover). Panel D 0 No additional screws required for Panel D. Panel E 0 No additional screws required for Panel E. Panel F (Wire Guard) wraps around the four Panel F sides of the unit and fastens to the Top Panel and (Wire NSA base pan via welding. The weld has been Guard) separately examined and deemed to adequately resist the uplift forces acting on the Top Panel. NO ADDITIONAL SCREWS REQUIRED Panel Integrity Summary Notes: SEP 12 k:? 3 No additional screws are required for wind pressures up to 1148 psf lateral & 117 pal' uplift Calculations were performed according to the information provided by the client for a worst -case unit (which was determined by this office to be a (32.25' W x 32.25' D x 43.25" H unit). Panels were assigned various porosities depending on the ratio of louver and/or opening areas to total panel area, for tension and shear calculation purposes. Screw quantities were checked to reinforce unit panels as needed. Weld strength was considered per client -provided specifications. CORP. OFC: 160 SW 122 AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 12 of 15 (954)354-0660 1 (866)396-9999 1 TEAm@ENGINEERINGEXPRESS.COM i ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering Ex, °" I TER-20-32211 PANEL DESIGNATIONS: LOUVER UNITS, ELITE SERIES SEP 1 2 7ruD FRONT ISOMETRIC VIEW BACK ISOMETRIC VIEW #1 BACK ISOMETRIC VIEW #2 1.3 SCALE: NTS 3 SCALE: NTS 3 SCAIE: NTS NOTE: The unit depictions in Details 1113 through 3/13 are for illustrative purposes only. Actual units may vary slightly in appearance. Louvers on Panels G, H, & L (Wall Panels) are not shown in full. Louver direction may be horizontal or vertical. Circled regions above illustrate additional screw locations per the additional screw directives below. This page applies to Elite Series lower units; see pages 3 through 7 for cabinet type classifications. PANEL INTEGRITY SUMMARY: LOUVER UNITS, ELITE SERIES Up to 167 psf lateral & 53 PSI Uplift Wind Pressures Panel Additional Designation Scr°cos Additional Screws Directive Required Top 0 No additional screws required for Panel #2 Top Panel #2. PanelC (Control Box 0 No additional screws required for Panel Cover) (Control Box Cover). Panel 0 No additional screws required for Panel 0. Panel E 0 No additional screws required for Panel E. Panels (Front Wall 2 Install (2) screws along the right edge of the Front Panel) Wall Panel W join with Panel I(Comer Post). Panel N Install (4) screws along the right edge of each Side ISide Wall 4 Wag Panel to join with Panel I's (Corner Posts). Panel) Note: (4) per Panel H, (8) total. Panel ( (Comer 0 No additional screws required for Post) Panel I's (Corner Posts). Panel l (Back Wall 2 Install (2) screws along Me fight edge of Side Back Panel) Wall Panel to join with Panel ((Comer Post). (12) ADDITIONAL SCREWS REQUIRED IN TOTAL Up to 148 psf Lateral & 117 psf Uplift Wind Pressures Panel Additional Designation Screws Additional Scrawl Directive Required Top 0 No additional screws required for Panel #2 Top Panel #2. Panel (Control Box 0 No additional screws required for Panel Cover) (Control Box [over). Panel 0 No additional screws required for Panel D. Panel 0 No additional screws required for Panel E. Panel G (Front Wall 5 Install (5) screws along the right edge of the Front Panel) Wall Panel to join with I(non-lowered Comer Post) Panel H Install (8) screws along the right edge of each Side (Side Wall 8 Wall Panel to join with Panel I's (Corner Posts). Panel) Note: (8) per Panel H, (16) total Panel (Comer 0 No additional screws required for Post) Panel I's (Comer Posts). Panel kW (Back Well 7 Install (7) screws along the right edge of Side Back Panel) Wall Panel to join with Panel l(Comer Post). (28) ADDITIONAL SCREWS REQUIRED IN TOTAL Panel Integrity Summary Notes: Q WARNING: HIGH PRESSURE REFRIGERANT HAZARD No additional screws are required for Exercise caution while installing additional screws into the Wind pressures up to t 24 psi lateral & 19 psi u Ip Ift 1 unit to avoid piercing refrigerant lines behind panels. Calculations were performed according to the information provided • Refrigerant fluid is under high pressure. by the client for a worst -case unit (which was determined by this office to be a (39.5" W x 35.5" D x 47" H unit). Panels were assigned various porosities depending on the ratio of louver area to total panel area, for tension and shear calculation purposes. Screw quantities were checked to reinforce unit panels as needed. Additional screws shall be #8 min. diameter SAE GR. 2 or stronger SMS. They shall be positioned according to the "Additional Screws Directives" in the tables above and Details 1/13 and 2/13. Provide 1- min. spacing between neighboring screws (existing or additional). Distribute additional screws evenly between left and right sides of the panel U.N.O. Validate that each additional screw joins the panel to the 24 GA min. thick steel member. Screw sizes, quantities on panels, and panel characteristics are according to client's description. 1000 hours of ASTM B117 are required with zero red rust for all additional screws. CORP. OFC: 160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 13 of 15 (954)354-0660 1 (866)396-9999 1 TEAM@ENGINEERINGEXPRESS.COM I ENGINEERINGEXPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering Expres- I TER-20-32211 PANEL DESIGNATIONS: LOUVER UNITS, DAVE LENNOX SIGNATURE COLLECTION n SIDE VIEW - LEFT /il FRONT ISOMETRIC VIEW 14 SCALE: I 14 SCALE: NTS e I FJ �K� ,2BACK VIEW ,14 1 SCALE: NITS NOTE: The unit depictions in Details 1I13 through 3113 are for illustrative purposes only. Actual units may vary slightly in appearance. Lowers on Panels G, H. 8 K (Wall Panels) are not shown in full. Lower direction may be horizontal or vertical. Circled regions above illustrate additional screw locations per the additional screw directives below. This page applies to Dave Lennox Signature Collection louver units: see pages 3 through 7 for cabinet type classifications. PANEL INTEGRITY SUMMARY: LOUVER UNITS, DAVE LENNOX SIGNATURE COLLECTION Up to 167 psf Lateral & 53 psf Uplift Wind Pressures Panel Additional Designation Screws Additional Strewn Directive Required Top D No additional screws required for Panelg3 Top Panel as. Panel G (Fren[ 2 Install (2) screwalong the right edge of the From s Panty)) Wall Panel to join with Panel )(Comer Post). Panel It Install (4) screws along the right edge of each Side (Side Wall 4 Wall Panel to join with Panel I's(Comer Posts). Panel) Note: (4) per Panel H, (a) total. Panel D No additional screws required for (Comer Post) Panel I's(Comer Posts). Panel J Install (2) screws along bottom left and right edges (Back Access 2 of Panel J. Equally distribute screws between left Panel) and right sides. (PanelK SSmalmaller D No additional screws required for Panel K's(smaller Back Panels) back panels). (12) ADDITIONAL SCREWS REQUIRED IN TOTAL Up to 1148 psf Lateral & 117 psf Uplift Wind Pressures parcel Additiolal Designation screws Additional Screws Directive Required Top D No additional screws required for Panel g3 Top Panel e3. PanelInstall(5) (FronttW Wall S screws along the right edge of the Front Panel) Wail Panel to join with Panel I (Comer Pon). Panel H Install (8) screws alongthe right edge of each Side (Side Wall 8 Wall Panel to join with Panel I's(Corner Posts). Panel) Note: (8) per Panel IN, (16) total. Panel G No additional screws required for (Comer Post) Panel I's(Comer Posts). Panel) Instan(8) screws along bottom left and right edges (Back access 12 of Panel J. Install (4) screws along top left and right Paneg edges of Panel J. Equally distribute screws between left and right sides. PanelK (Smaller D No additional screws required for Panel lrs(smaller Back Panels) back panels). () ADDITIONAL SCREWS REQUIRED IN TOTAL Panel Integrity Summary Notes: Q WARNING: HIGH PRESSURE REFRIGERANT HAZARD No additional screws are required for Exercise caution while installing additional screws into the Wind pressures up to 124 psf lateral & 19 psf uplift I unit to avoid piercing refrigerant lines behind panels. Calculations were performed according to the information provided • Refrigerant fluid is under high pressure. by the diem for a worst -case unit (which was determined by this office to be a (39.5" W x 35.5" D x 47" H unit). Panels were assigned various porosities depending on the ratio of louver area to total panel area, for tension and shear calculation purposes. Screw quantities were checked to reinforce unit panels as needed. Additional screws shall be #8 min. diameter SAE GR. 2 or stronger SMS. They shall be positioned according to the "Additional Screws Directives' in the tables above and Details 1113 and 2113. Provide 1" min. spacing between neighboring screws (existing or additional). Distribute additional screws evenly between left and right sides of the panel U.N.O. Validate that each additional screw joins the panel to the 24 GA min. thick steel member. Screw saes, quantities on panels, and panel characteristics are according to client's description. 1000 hours of ASTM 8117 are required with zero red rust for all additional screws. CORP. OFC: 160 SW 12T AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 14 of 15 (954)354-0660 1 (866)396-9999 1 TEAM@ENGINEERINGEXPRESS.COM i ENGINEERINGExPRESS.COM Lennox Merit, Elite, & Dave Lennox Signature Collection Engineering Tres I TER-20-32211 APPENDIX A: DESIGN WIND PRESSURE GUIDE Max. Ult. Wind Speed IVA Max. MRH (Roof Height) Exposure Category Required Design Wind pressures(ASD) lateral Pressure Uplift Pressure 140 mph At -Grade t0 ft) C 26 psf 21* psf D 31 psf 25* psf 100 It C 67 psf 53 psf D 75 psf 59 psf 200 ft C 76 psf 60 psf D 84 psf 67 psf 175 mph At -Grade (0 ft) C 40 psf 32* psf D 49 psf 39* psf 100 ft C 104 psf 82 psf D 117 psf 93 psf 200 ft C 119 psf 94 psf D 131 psf 104 psf 186 mph At -Grade (0 ft) C 46 psf 36* psf D 55 psf 44* psf 100 ft C 117 psf 93 psf D 132 psf 105 psf 200 ft C 135 psf 106 psf D 148 psf 117 psf Indicates a design wind pressure that Is not approved for use by this evaluation. Seek additional engineering or contact this office for design solutions. UNIT REACTIONS FROM WIND GUIDE DIRECTIVE: This design pressure guide is for reference only and shall be approved for use by the Authority Having Jurisdiction (AHJ). If the design pressures listed in this guide are not used, required design pressures shall be calculated on a site -specific basis by others. For site -speck scenarios classified as Exposure Category B, the required design pressures stated for Exposure Category C in the above guide shall be used or design pressures shall be calculated separately. For heights and parameters beyond the above values, consult with an engineer for a site -specific analysis. The required ASD design pressures listed in the above guide were calculated based on the parameters listed below. The project design professional or permitting contractor shall verify that the site -specific conditions are equal to or less than the design parameters listed below. *Note: Per the codes and standards referenced herein, uplift is optional for mechanical equipment at -grade. At the discretion of the AHJ, uplift may be taken as 0 psf or as the value listed in the guide. At -Grade (0 ft MRHI Required Destan Pressures: o ASCE 7 "Design Wind Loads: Other Structures o Structure Shape = Square, flat terrain o Height of structure (unit+ stand or curb, if used) = 6 it max. o Width of unit =1 It min., Depth of unit = 1 It min. o Uplift Pressure = Lateral Pressure x 1.5 / 1.9 (if considered) Rooftop (>15 ft MRHI Required Destan Pressures: o ASCE 7 "Design Wind Loads: Other Structures: Rooftop Structures and Equipment for Buildings" o Structure Shape = Square, flat terrain o z=up to7ft, wherez= heightof stand orcurb+%unit helght o Lateral GCr= 1.90; Uplift GG= 1.50 VISIT ECALC.10/FORCES 0 0 FOR HELP DETERMINING DESIGN PARAMETERS AND TO SEE MORE EXAMPLES, ❑ OR SCAN THE QR CODE TO THE RIGHT> U DIRECTIVE: This guide is intended for use by a design professional. Design parameters shall i abide all specifications and limitations stated in this report. Design professional shall consider all forces, including seismic and snow loads, per governing building code. Unit reactions • — D/2 obtained from this guide shall be vertfiied by a registered Professional Engineer. Reactions are applicable for unit -to -host connections only. Sample calculations are provided below. Design Parameters: D - Lateral Wind Pressure. P—lat - Uplift Wind Pressure, Pup - Unit Height, H - Unit Depth, D - Unit Width, W - Unit Weight, Wit L — _ - Support Spacing across Depth, ad - Support Spacing across Width, sw ry t Unit Reaction Equations: = Wt Long Side (Width x Height): Short Side (Depth x Height): - Sliding Force, L= P tat x W x H - Sliding Force, L= P_let x D x H sd - Uplift Force, U= Pup x W x D - Uplift Force, U= P_up x W x D - Total Tension per Long Side = - Total Tension per Short Side = (LxH/2+Uxsdl2—Wtx 0.6 xsd/2 )/sd (LxH/2+U xsw/2—Wtx 0.6xsw/2)/sw Example: A (48" W x 36" D x 42" H), 250 lb net weight unit at wind pressures of 120 psf lateral and 95 psf uplift, on a 24" wide roof stand, shall have the following unit reactions: Lona Side (Width x Height): Short Side (Depth x Height): 1, Sliding Force, L= Plat x W x H 1. Sliding Force, L= Plat x D x H = (120 psf) x (48 in) x (42 in) x (1 in'/ 144 ftz) = 1680 lb = (120 psf) x (36 in) x (42 in) x (1 in'/ 144 ft') = 1260 lb 2. Uplift Force, U= P_up x W x D 2. Uplift Force, U= P up x W x D = (95 psf) x (48 in) x (36 in) x (1 in'/ 144 It) =1140 lb = (95 psf) x (48 in) x (36 in) x (1 ina/ 144 fF) = 1140 lb 3. Total Tension per Long Side = 3. Total Tension per Short Side = =(Lx H12+U xsd/2—Wtx 0.6xsd/2)/ad =(LxH/2+Uxsw/2—Wtx 0.6xsw/2)/sw =((1680 lb x4212 in) +(1140 lb x 24/2 in)—=((1260 lb x42/2 in) + (1140 lb x 48/2 in) — (250 lb x 0.6 x 2412 in) ) / 24 In = 1965 lb (250 lb x 0.6 x 48/2 in) ) / 48 in = 1046 lb IN ALL CONDITIONS IT IS THE RESPONSIBILITY OF THE PERMIT HOLDER TO ENSURE THE HOST STRUCTURE IS CAPABLE OF WITHSTANDING THE RATED GRAVITY, LATERAL, AND UPLIFT FORCES BY SITE -SPECIFIC DESIGN. NO WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED, IS OFFERED BY ENGINEERING EXPRESS AS TO THE INTEGRITY OF THE HOST STRUCTURE TO CARRY DESIGN FORCE LOADS INCURRED BY THIS UNIT. CORP. OFC: 160 SW 12r AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 15 of 15 (954) 354-0660 1 (866) 396-9999 1 TEAM@ENGINEERINGEXPRE55.COM I ENGINEERINGExPRESS.COM Certificate of Product Ratinqs AHRI Certified Reference Number: 208808192 Date : 09-05-2023 Model Status: Active AHRI Type; RCU-A-CB (Split System: Air -Cooled Condensing Unit, Coil with Blower) Series: MERIT ML17XC1 SERIES Outdoor Unit Brand Name : LENNOX Outdoor Unit Model Number (Condenser or Single Package) : ML17XC1-048-23OA" Indoor Unit Model Number (Evaporator and/or Air Handler) : CBA25UH-048-230-- Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SO, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: On January 1, 2023, efficiency standards increased for central air conditioners. Beginning January 1, 2023, central air conditioners can only be Installed in region(s) for which they meet the new regional efficiency requirements. The manufacturer of this LENNOX product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 - 2017 with Addendum 1, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 47000 SEER: 15.10 EER (A2) - Single or High Stage (95F) : 12.20 Rated as follows in accordance with the latest edition of AHRI 210/240 —2023, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (AFuu) — Single or High Stage (95F), btuh : 45500 SEER2 : 14.70 EER2 (A Full) — Single or High Stage (95P) : 12.20 t'Active' Model Status are those that an AHRI Cedificabon Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced.'Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS Indicate an involuntary re -rate. The new published rating is shown along with the previous (i.e. WAS) rating. The Department of Energy has published updated energy efficiency metdcs for central air conditioners and heat pumps. This publication reflects both the 1987 metric (SEER) and the 2023 metric (SEER2). Efficiency requirements are published at 10 C.F.R. 430.32(c). Please refer to www.AHRlnet.org for more Information about updated energy efficiency metrics. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are wild only for models and configurations listed In the directory at www.ahridirectory.org. TERMS AND CONDITIONS , This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and A1413- 1 confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated;OMM .` `' entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's Individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be "rifled at www.ahridirectory.org. click on 'Verify Certificate" link we make lire better and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certtflcete No., which Is listed at bottom right ©2023Air-Conditioning, Heating, and Refrigeration Institute I CERTIFICATE NO.: 133384164398152937 R Ron DeSantis, Governor STATE OF FLORIDA Melanie S. Griffin, Secretary DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION Always verify licenses online at MyFloridaLicense.com Do not alter this document in any form. This is your license. It is unlawful for anyone other than the licensee to use this document. 00eses Local Business Tax Receipt Miami —Dade County, State of Florida -THIS IS NOTA BILL -DO NOT PAY 3870533 BUSINESS NAMFAOCATIOM RECEIPTUD. CENTRAL COMFORT AIR CONDITIONING CORMENEWAL 12310 SW 129TH CT 4040861 MIAMIFL33186-6500 EXPIRES SEPTEMBER 30, 2023 Must be displayed at place of business Pursuant to County Coda Chapter SP. -Art. 9 St 10 0wtax SEC.TYPEOFBUSB/6S PAYMMBSCENES CEMRAL COMPORT AIR CONDITIONING CORP 196 SPEC MECHANICAL CONTRACTOR "7131 u 6 C/O ALF%MWNEZ QUAURER CAC057552 $75.00 07/19/2022 Worker(s) 1 CHECI(21-22-048803 This Local Business Tax Receipt only confirms payment of the Local Business Tax. The Receipt is am a license, permit "a certification of the holder cqualificatiorm, to do business. Holdermust comply with any governmental or nongovernmental regulatory laws and mquirementwhich apply to the business. The RECEIPT NO. above must be displayed on all commercial vehicles- Miami -Dade Code Sec Sa-276. For more information, visit vvwwm'emidade oovtaxcollector CENTCOM-01 BPOPOVSKA DAB! 6, 02D23 CERTIFICATE CIF LIABILITY INSURANCE THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorseme s . PRODUCER C ar CIC Hotalin�ggInsurance Services LLC 2301 NW 87M Ave Suite 401 _ PHONE' Fax LAIC. No Ext : 306393-8981 A/C, No : 845 471-7494 . cartificatesMIA@hgfin.net Doral, FL 33172 AFFORDING COVkRAGE NAIC ii IKSISRERA_Tokio Marine Specialty 23850 INSURED INSURER B INaINE.R C Central Comfort Air Conditioning Corporation INSURER D : 12310 SW 129 CT Miami, FL 33186 INSURER >~ INSURER F • COVERAGES CERTIFICATE NUMBER: REVISION NUMBER; THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. rypE OF INSURANCE ABDL BR POLICY NUMBER POLICY POLICY EXP LIMITS rA X COMMERCIAL GENERAL LIABILITY CLAIMS.MADE CJX OCCUR X X PPK2524B34 2/23=23 2123/2024 EACH OCCURRENCE$ 1,000,000 DAMAGE TO RENTED PREMISES (Ea OMM02M $ 100,000 MID W one rson GEN'L PERSONAL A AQV INJURY 1 1,000,000 AGGREGATE LIMIT APPLIES PER: ^� POLICY ❑ 11: F-1 LOC OTHER: GENE GATE 2,000,000 PRODUCTS - COMPIOP AGG 2,000,000 AUTOMOBILE LIABIUTY ANY AUTO OWNED AAUUTTNOOSyU��D AHFC% ONLY AUTOS ONLY COItiIBINED SINGLE LIMIT BODILY IN.IU�tY BODILY INJURY Par ecdclam ri eratxicMra GE $ UMBRELLA LIAS EXCESS LAB OCCUR CLAIMS -MADE EACH OCCURRENCE AGGREGATE DED + RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y I N ANY PR_Oj�RIETORIPAF EROMCUTNE CEEww �Wu endatory M EXCL DED? Ifyes d*=Ie under DESCRIPTION OF OPERATIONS below NlA PER OTii- STATUTE I E.L. EACH ACCIDENT E.L DISEASE • EA 1503LOYEE �_._.. S E.L DISEASE - POLICY LIMIT Ii I DESCRIPTION OF OPERATIONS I LOCATIONS 1 VEHICLES (ACORD 101 AtldManal Remarks Schedule. may be sttatdW If inoi spew is roqulrad Certificate Holder is included as an additional Insured wlih respect to General L16bllIty on a primary and non-contributory basis when required by written contract. Waiver of Subrogation applies where required by signed, written contract. License# CAC057SS2 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Miami Shores Village Building Department THE EXPIRAON DATE THEREOF, NCE ACCORDANCEnWITH THE POLICY PPROVISIOOTI WILL BE DELIVERED IN 10050 HE 2nd Ave Miami Shores, FL 33138 AUTHORIZED REPRESENTATIVE ACORD 25 (2016103) 01988.2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD 76 acoRV CERTIFICATE OF LIABILITY INSURANCE �•• DATE (MMlDDIYYY1f) 09I12/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME CT Marsh Affinity Marsh Affinity FAX At No. Ext : 800-743-8130 AIC No): E-MAIL ADPTotalSourcewmarsh.com ADDRESS: a division of Marsh USA LLC. PO BOX 14404 Dos Moinas, IA 50306.9686 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A: Illinois National Ins Co 23817 INSURED INSURER B: INSURER C : ADP TotalSource I, Inc. INSURER D: 5800 Windward Parkway Alpharetta, GA 30005 Alternate Employer: INSURER E: INSURER F: Central Comfort Air Conditioning Corporation 12310 SW 129TH CT Miami, F L 331860000 COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN: THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPEOFINSURANCE ADDL INSD SUBR WVD POLICY NUMBER POLICY EFF (MMIDDIYYYY) POLICY EXP (MMIDDIYYYY) LIMITS COMMERCIAL GENERAL LIABILITY CLAIMS -MADE ❑ OCCUR EACH OCCURRENCE S DAMAGE TO RENTED PREMISES Ea occurrence S GEN'L MED EXP (Any one person) S PERSONAL & ADV INJURY S AGGREGATE LIMIT APPLIES PER* POLICY PRO LOC OTHER JECT GENERAL AGGREGATE S PRODUCTS - COMP/OP AGG S S AUTOMOBILE LIABILITY ANY AUTO OWNED SCHEDULED AUTOS ONLY AUTOS HIRED NON -OWNED AUTOS ONLY AUTOS ONLY COMBINED SINGLE LIMIT Ea accident S BODILY INJURY (Per person) S BODILY INJURY (Per accident) S PROPERTY DAMAGE Per accident S S UMBRELLA LIAR EXCESS LIAB _ OCCUR CLAIMS -MADE EACH OCCURRENCE S AGGREGATE S DED RETENTION S $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY YIN ANYPROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory in NH) it yes, describe under DESCRIPTION OF OPERATIONS below NIA WC 034274994 F L 07/01/2023 07/01/2024 X ATUTE ER E.L. EACH ACCIDENT S 2.000,000 E.L. DISEASE -EA EMPLOYEE S 2.000.000 E.L. DISEASE - POLICY LIMIT S 2 000 000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101. Additional Remarks Schedule, may be attached if more space is required) All worksite employees working for Central Comfort Air Conditioning Corporation paid under ADP TOTALS0URCE. INC.'s payroll, are covered under the above stated policyy. Central ComfortAir Conditioning Corporation is an alternate employer under this policy. LICENSE+f CAC057552 LICENSE;* CAC057562 CERTIFICATE HOLDER CANCELLATION Miami Shores Village Department 10050 NE 2nd Ave Miami Shores, FL 33138 26 (2016/03) SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE 01988-2016 ACORD CORPOFWION. All rights reserved. The ACORD name and logo are registered marks of ACORD