Loading...
FW-09-23-2389Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 11/21/2023 Location Address Parcel Number 29 NE 109TH ST, Miami Shores, FL 33161 1121360040600 Contacts��- Permit No.: FW-09-23-2389 Permit Type: Fence/Wall Work Classification: Wire Fence Permit Status: Approved Expiration: 05/21/2024 JACQUELINE GONZALEZ Owner I 29 NE 109TH ST, Miami Shores, FL 33161 Mobile: 3052818409 RAAB4.JIMENEZ@YAHOO.COM HOMEOWNER Contractor HOME OWNER Mobile:3054507783 administration@excelmanagement. net Description: CHAIN LINK Valuation: $ 100.00 Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $0.60 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.30 Planning and Zoning Review Fee $70.00 Scanning Fee $9.00 Technology Fee $10.00 Wire and Wood Fence Fee $50.00 Total: $193.90 Ins ection Requests: Payments Date Paid Amt Paid Total Fees $193.90 Credit Card 11/21/2023 $143.90 Credit Card 09/27/2023 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFF AVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating ruction and zoning. Futhe/n/nq/te, I authorize the above named contractor to do the work stated. ' �l �i V / /'�-L .1 f Z l - Z / - 2? Author' ed i re: Owner / Appr nt / Contractor / Agent Date November 21, 2023 Page 2 of 2 BUILDING PERMIT APPLICATION 121�1­1ILDING I3 ELECTRIC PLUMBING I3 MECHANICAL JOB ADDRESS: City: Folio/Parcel#: Occupancy Type: Miami Shores Village [F:SEP M T D d Building Department 272023 D10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 zq uE Loy —Z/3ro Load: OWNER: Name (Fee Simple Titlel \ Arirlracc• 2 "G iC) FBC 202.0 - Master Permit No.-F( . �� L —2b'?Y6�, Sub Permit N [I 3 ROOFING ® REVISION I3 EXTENSION ©RENEWAL CHANGE OF CANCELLATION ® SHOP CONTRACTOR DRAWINGS Sir ej - 0000 F the Building Historically Designated: Yes NO Construction Type: Flood Zone: BFE: FIFE: $b5 �L%1-64 0 1 City: r'C I a`^^+ State: T� Zip: 5 V 6/ Tenant/Lessee Name: Phone#: Email: ).0.G:L-Q„ O `v D I, V CL__�vo -C CONTRACTOR: Company Name: 1 �'^-� w� Phone#: Address: �c .ti.�rt_ cc .S AAG o .J -2i Email: Qualifier Name: Phone#: State Certification or Registration #: DESIGNER: Architect/Engineer: _ Value of Work for this Permit: � a of Competency #: _City: State: _Zip: TT Square/Linear Footage of Work: r L 1" Type of Work: I3 Addition 0 Alteration M New \ I3 Repair/Replace ® Demolition te� Description of Work: l U-L-ct""'- Ltw1� Specify color of color thru tile: Submittal Fee $ SS) go ' Permit Fee $ CCF $ CO/CC $ - - - Scanning Fee $ Technology Fee DCA Fee $ Training/Education Fee $ DBPR $ Notary $ Double Fee $ P&Z Review $ Bond $ TOTAL FEE NOW DUE$ iy3•a� Structural Reviews $ (Revised04/05/2022) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien low brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved qnd a reinspection fee will be charged. OWNER The foregoing instr��\\ nnt was ackno ledged before me this day of CJT. , 20 L.7 , by IF �d�.9�. 00 09� 3�01 who is personally known to me or who has produced 52-� 4 W q� 3 3 + as identification and who dh to an opth. L NOTARY PUBLIC: Sign: Print: Seal: ********»»***** APPROVED BY (Revised04/05/2022) Signature CONTRACTOR The foregoing instrument was acknowledged before me this day of me or who has produced 20 ,by who is personally known to identification and who did take an oath. NOTARY PUBLIC: d1 v tY Y" Print: HEBERT MARTINEZ Seal: MY COMMISSION # HH 323276 EXPIRES: October 18, 2026 11 as Plans Examiner /'/ . _ /7Y//�iOC�. Zoning 10/1(1 UZ3. s-2 Structural Review Clerk �C l� � SEP2i SEP 2 7 2023 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNER BUILDER DISCLOSURE STATEMENT NAMEj6AT tyt4. Qvvt-2-zG-2 DATE: lZ� I 23 ADDRESS:-2-1 NE (O`[ r' ,cxwu - l 33L(p Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, RS 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with -holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. Initial 2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. 1 understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial 4. 1 understand that I may build or improve a one family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction Is complete, the law will presume that I built or substantially improved it for sale or lease, which violates the exemption. Initial S. I understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. Initial 6. 1 understand. that I.may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial 7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously implies that the property owner is providing his or her own labor and materials. 1, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowners insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial 8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow these may subject to serious financial risk. Initial 9. 1 agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govern owner -builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial 10. 1 understand that I may obtain more information regarding my obligations as an employer from the rnal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 950.487.1395 or htto://www.mvforidalicense.com/dbor/pro/cilb/index.html Initial 11. 1 am aware of, and consent to; an owner -builder building permit applied for in my name and understands th t I am the party legally and financially responsible for the proposed construction activity at the following address: E 10 -L Initial 12. 1 agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information that I have provided on this disclosure. Initial Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who ibes not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit. A copy of the property owners driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this 2� day of 20 23 By G 52y 9 _M '918311 who was personally known to me or who has identification. gt"•n"k•; HEBERT MARTINEZ ARy '•. ,•= MY COMMISSION p HH 323276 ;x. •;d •'�_...�efr EXPIRES: October 18, 2026 OFFICE OF THE PROPERTY APPRAISER Summary Report Folio 11-2136-004-0600 29 NE. 109 ST Property Address MIAMI SHORES, FL 33161-7039 Owner JACQUELINE GONZALEZ Mailing Address 29 NE 109 ST MIAMI SHORES, FL 33151 Primary Zone 1000 SGL FAMILY- 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: I UNIT Beds / Baths /Half 3/2/0 Floors Living Units 1 Actual Area 2,056 Sq.Ft Living Area 1,727 Sq.Ft Adjusted Area 1,808 Sq.Ft Lot Size 9,150 Sq.Ft Year Built 1946 Year 2023 2022 2021 Land Value $512,493 $320.032 $262.833 Building Value $217,177 $167,059 $125,837 Extra Feature Value $2,560 $2,589 $2,618 Market Value $732,230 $489.680 $391,338 Assessed Value $385,371 $374,147 $363,250 Benefit Type 2023 2D22 2021 Save Our Homes Assessment S346,859 $115,533 $28,088 Cap Reduction Homestead Exemption $25,000 $25,000 $25,000. Second Exemption $25,000 $25,000 $25,000' Homestead '.Note; Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). I u< COLLEGE HEIGHTS PB 42-8 LOT 30 BLK 2 LOT SIZE 75.000 X 122 OR 19223-4565 07 2000 1 Generated On: 09/26/2023 Year 2023 2022 2021 COUNTY Exemption Value $50,000 $50,000 $50,000 Taxable Value $335,371 $324,147 $313,250 SCHOOLBOARD - Exemption Value $25,000 $25,000 $25,000 Taxable Value $360,371 $349,147 $338,250 Cm Exemption Value $50,000 S50,000 $50,000 Taxable Value $335.371 $324,147 $313,250 REGIONAL Exemption Value $50,000 $50,000 $50,000 j Taxable Value $335,371 $324,1417 $313,250 .. .wl I•I I, Previous Price OR Book Quali ication Description Sale Page 08/20/2018 $445,000 31116-0960 Qual by exam of deed 01/1112018 $100 30825-4218 Corrective, tax or QCD; min consideration 10/04/2017 $100 30823-1990 Corrective, tax or QCD; min consideration 02/20/2015 $100 29533-0760 Corrective, tax or QCD; min consideration The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:/1www.miamidad e.gov/info/disclaimer.asp SEP 27 2023 CITY A 0 10 20 Id^MPS` SCALE: I • 20' C GJ. t o k i t—, 1�t hC.0 +mpW4Pa=42 15 rally (par'842-P{l. B) one SUTY Resider" No. 29 74.11T M. 7£.0D'P. P essay N.E. 10901 Street to TbNI RNV too, PB 42- Pg W I 181'AgMRPMmPN tP -- � Mwbn V1L--- Fence Good Side Cat a -) g, Tie vertical and horizons' '. ` r members of a fence shalt fat:. tre of the plot on which the fe' ce Is l -' `'` ;nd the finished side shuii 'tic hi ofawlay'. lot or any abutting 9 re. aJyi. 6dw °4 73.00' If. 76.00' V. 1 bmMX, IyaN,2 dLo 28 'a'sidensi Ld;— IonPIP IIbA 2 LEGAL DESCRIPTION: ® � Lot Arcrded In P11ook Q Nok 2, C>ILEGE h EIGMS.acpr .r�c 42, N, i 8 of Me %Wc Retards o/ Niami-Dah�<ounry,llaRaa. SURVEYOR'S RE➢ORT AR D GENERAL NOTES (Novel d wMout fe a1NCM1nd Survey Map) 1. Leysl DesoRPan hasbemlumisNst byes, tlierM1 2 RNemmw N'Daed', Tanomo' °,'Pled tiler N dooaona and inNrvmerm f semi! Am pedd MM Ppi�aRiMwllotbn sand/"Mls aurveY verk Mea.rteddNb,ces.M.m m And angles :dog Wu star, line. are in immamy vaM oresxindin, vaM1les horn moo its, unlm. omen ehwm. 3. This am& w em hpcl toaldmNoul dried me ofMethotmnrd Nk,ere t fishamW b, Me m os "nine Agatef0! survaya. A title search has not awn p sk,eyed by Me savetar. 4. Not, arrox encpon N headed on an wemmd "Alan. Beuhpe ere Weed m an saYlwa morklan m a i.el"Madslmd Mtn. sand )as Ia Wh a PM M RR m Me Bsrvey Map 5. ON, abwa gralmd km+IMelPnb are Nos, Wish, Pommatior, , und.,n m d Mums aW fildw nem net bwn bca1M. E. Survey mortise Rome it Me Ask: have no idenfio'm most, oMeoise eWan. Any sue ry "Amin, set by our condo, s labeled -B 7282 a' PSM e1Cg. T Fema aercmaV hu hit even drtalmin. Dabnces Man eebWg ft.. to boundary law tie epprtxhreN. FmcsVmla sift ea disid.i must be considered b debt one Mo. kMpeat tend. bceed beyonl Ponds, host nigh or MI cot W Wing.4 y Wien. M1Een, W.Ia more as Main inaN'gaM 8. This Suney M sp d abnded to W laliaYed At Me seals Nova naeon. Daa is examemd n U S. Sanity Foot 0. This Survey Nip a Waal Pmepnet for Me me of Me PARyyPNe, Met A A xdRM N and dap M eNen! M any u meimd Mdvndwl, a 1My or angnw. IO.1al.000PUIN INFORMATION: AI soled lam Fademl masomas RAN Map (FIRM) of Cmmunby W- 12t1852 YYlsgis of MNM Stew), PMNI 0130, A L. timed m Sept 11M2 ,, Mi.real pmPntyfallsit 2ow')f' ILNOFRONTAL ACCUR ICY: Acsnay .14maa Mn menanmenN aid obulAbns "wA end Moved. Me Mnimum wr¢afal isaNm Mousey b . SVWMw area tsing "Who 1 foot m 7, 500 thet 12.VERTMAL CNNTROL AND ACCURACr.. "W Maylow Re Noee an War" b the NaNwl Gedadc VeRcd DaNm c1102B (W 3VD 1828. TM osdom In fes as ed"Asd, mea s the Nandand of ph5 a moue O,M NN Wsm Me egwM nit f Me IMP ONtands M MI ElyNol are bawd me Mel bop hen and a tle follosap o cal Dinah Mvb: Ben h Malk R I: MIaM.Cade Couny Publk VAMs bpmment Bench MAM N3W, Eavitan=B.Ci fist( Ben A Mark d ): MIeM-EMN Coup y Publb Vamm Depnlmef By non Mef N6 Eav iban =10 78 feet €0 I � MSV PLANNING DEPARTMEN f1 /f� VED DATE: Ill/ l M-10 L ' Yyr �jRFPrqn. )aohidam De7g ,. • leZcn /9e�icY.ec as g I_ � • H That tbi SUrvy"hinnsor Me BNmNnda of RAM. ws.N fxth bl Me Flared. Bwnd f Proacs mel Sm,,yas.na Mapwm k, apMPI P... f doper 51-17, Flonaa l720Y7 FbWa SCRUM. Thli Survyk..yv%and ' admaaoe4e Mote Pursvan:NSeetlol owned p M.MhodinykmMed,a^tlWist J 7 OYPCRb e41.e. Radiruw in V aamvam m . g59 vasealDYvesOAS. Casio w ) tb 3 a®maa_enal. oa.ryM =:. BaaamP n + ® PiendWA Sunnryorana napperLsiiBB.9alaa Fkala, �; =. Flektwxk D.N:Inn4rz02s. M E oE= ?E �IL0 MeiY—toson Ilse R, aso SeenmM WdvM.wlMetiP amn am rays alowac. M. MeaWea elW mk rp m<aM•dls W u.tva Pna Fl .—,ed SnwywaM fame----// . ,mammon .frmru ..m.aern re nru ".-.. -.n Mu � 0..� "•'• • :� -e :` :D , .,e.e Pmp e0y Adc ress: I • ..,..,. ea.era� n m..•.., ....,.•.. '•'eR"e" xT .,n...�n �•^��"` •—m ;' ?;,� 29 N E. 109th Street, Miami Bootee, Floritla 32161 .�vn tie, e.e.enn.. a :2=.....n 1 '^'^"" •'a.�'os W""' Pmja ct No. 2315O D.e.: MFE Right totl �ECEIIIE SEP 27 2023 Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795,2204 Fax: (305) 756.8972 CHAIN LINK FENCE DESIGN DETAIL (ACCORDING TO THE F.B.C. SECTION R4408.11) TABLE R4408.11 CHAIN LINK FENCE MINIMUM REQUEREMENTS Fence Terminal Post Line Post Dimensions Terminal Post Line Post Concrete Height (ft) Dimensions (in inches) Concrete Foundation Size (in inches) (o.d. X wall thickness) Foundation Size (diameter X depth) (o.d. X wall thickness) (diameter X depth) (in inches) in inches U to 4 2 3/8 x 0.042 1 5/8 x 0.047 10 x 24 8 x 24 Ov o6 x x0.05 x2 8x24 For SI:1 inch = 25.4 mm. NOTES: 1. This table is applicable only to fences with unrestricted airflow. 2. Fabric:12 %: gauge minimum, Black or Green. 3. Tension bands: Use one less than the height of the fence in feet evenly spaced. 4. Fabric Ties: Must minimum the same gauge of the fabric. 5. Fabric Tie Spacing on the Top Rail: Five ties between posts evenly spaced. 6. Fabric Tie Spacing on Line Posts: One less than height of the fence in feet, evenly spaced. 7. Either top rail or top tension wire shall be used. & Braces must be used at Terminal Posts if top tension wire is used instead of Top Rail. 9. Post Spacing: 10 foot (3m) on center maximum. 10. Post shall be embedded to within 6 inches If 52 mm) from bottom of the foundation. 11. In order to follow the contour of the land, the bottom of the fence may clear the contour of the ground by up to 5 inch (127 mm) without increasing table values to the next higher limit. NOTICE TO PROPERTIES WITH POOLS: If the fence is to meet the criteria as a pool barrier, the fence shall not be climbable and all rails must be placed facing the inside of the property. Pedestrian gates shall have self -closing and latching devices installed at the minimum of 54" above ground. For further details see Section R4401.7.1 of FBC. CONCURRED Created on 5122/2009 MLOV,06122@015