MC-11-23-2843Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305.795-2204 Permit No.: MC-11-23-2843 Permit Type: Mechanical - Residential Work Classification: A/C Replacement Permit Status: Approved Issue Date:11/28/2023 Expiration:05/28/2024 Location Address Parcel Number 9720 BISCAYNE BLVD, Miami Shores, FL 33138 1132060143260 —� Contacts ERIC MANDELL Owner ALL YEAR COOLING & HEATING INC - Contractor 9720 BISCAYNE BLVD, Miami Shores, FL 33138 CAC058159 Business: 9546295235 MANDELLERIC@YAHOO.COM THOMASSMITH 12494 STONEWAY CT, DAVIE, FL 33330 Business: 9545664644 permits@allyearac.com Inspeon Requests: Description: ac change out of a 5 ton trance split system Valuation: $ 5,600.00 OS 762 4949 Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $3.60 DBPR Fee $2.94 DCA Fee $2.00 Education Surcharge $1.80 Permit Fee $146.00 Scanning Fee $9.00 Technology Fee $19.60 Total: $234.94 Payments Date Paid Amt Paid Total Fees $234.94 Check# 19727 11/13/2023 $50.00 Check# 19756 11/28/2023 $184.94 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating con,ssttruction and zoning. Futhermore, I authorize the above named contractor to do the work stated. J_ ed Signature: Owner / —Applicant // Contractor / Agent r Date November 28, 2023 Page 2 of 2 Miami Shores Village Building Department h 1131 2(D�3 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 C� Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FmBC 20 ?P p BUILDING Master Permit No. ' hC — �I �Z3 �Z 0 �� PERMIT APPLICATION sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION [—]RENEWAL PLUMBING 0 MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 9720 BISCAYNE BLVD City: Miami Shores County: Miami Dade Zio: 33138 Folio/Parcel#:11-3206-014-3260 Is the Building Historically Designated: Yes NO Occupancy Type: RES Load: Construction Type: RES Flood Zone: BEE: FEE: OWNER: Name (Fee Simple Titleholder):ERIC MANDELL Phone#:954-629-5235 Address:9720 BISCAYNE BLVD \ City: MIAMI SHORES State: FLORIDA Tenant/Lessee Name: Phone#: Email: PERMITS@ALLYEARAC.COM 33138 CONTRACTOR: Company Name: ALL YEAR COOLING & HEATING Phone#: 954-799-0110 Address: 4300 NW 124 AVENUE City: CORAL SPRINGS State: FLORIDA Zip: 33065 Qualifier Name: THOMAS ARVID SMITH State Certification or Registration #: CAC058159 of Competency #: DESIGNER: Architect/Engineer: Phone#: 954-799-0110 Address: City: State:Zip:_ Value of Work for this Permit: $5600 Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New Q Repair/Replace ❑ Demolition Description of Work: AC CHANGE OUT OF A 5 TON TRANE SPLIT SYSTEM Specify color of color thru Submittal Fee $ Scanning Fee $ Technology Fee $ Structural Reviews $ Permit Fee $ CCF $_ Radon Fee $ DBPR $ Training/Education Fee $ CO/Cc $ Notary Double Fee $ Bond $ M ' TOTAL FEE NOW DUE $ l (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2SOO, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signat 6re4,2�.' Signature/ eVM& t. OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this 9 day of NOVEMBER 2U 23 , by 9 day of NOVEMBER , 2U 23 ___,by ERIC MANDELL , who is personally known to THOMAS A. SMITH , who is personally known to me or who has produced DRIVERS LICENSE as me or who has produced PERSONALLY KNOWN as identification and who did take an oath. NOTARY PUBLIC: identification and who did take an oath. NOTARY PUBLIC: Sign• Sign: Print: LO L RINGTON Print: L Seal- ary Public State of Florida Arrington 5 Lorellys WIM My Commission HH 335691 1f, Expires 11 /28/2026 ************ ******************** APPROVED BY v` ans xaminer Structural Review ARRINGTON Notary Public State of Florida Lorellys Arrington My Commission HH 335691 Expires 11/28/2026 Zoning Clerk (Revised02/24/2014) Summary Repoli Folio 11-3206-014-3260 Property 9720 BISCAYNE BLVD Address MIAMI SHORES, FL 33138-2541 Owner ERIC JORDAN MANDELL , ARIELLE REBECCA SHUTER Mailing Address 9720 BISCAYNE BLVD MIAMI SHORES, FL 33138 Primary Zone 1100 SGL FAMILY - 2301-2500 SO Primary Land 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT Use Beds / Baths 3 / 2 / 0 /Half Floors 1 Living Units 1 Actual Area 3,075 Sq.Ft Living Area 2,331 Sq.Ft Adjusted Area 2,703 Sq, Ft Lot Size 11,688.3 Sq.Ft Year Built 1972 Year 2023 2022 2021 Land Value $654,392 $526,689 $318,643 Building Value $132,339 $274,758 $208,671 Extra Feature Value $1,385 $1,385 $1,403 Market Value $788,116 $802,832 $528,717 Assessed Value $788,116 $233,025 $226,238 Benefit Type 2023 2022 2021 Save Our Homes Assessment $569,807 $302,479 Cap Reduction Homestead Exemption $25,000 $25.000 $25,000 Second Exemption $25,000 $25,000 $25,000 Homestead Widow Exemption $500 $500 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). MIAMI SHORES SEC 3 PB 10-37 LOT 3 & SWLY 39.91 FT OF LOT 2 BLK 78 LOT SIZE 89.910 X 130 OR 17844-3303 0996 4 Generated On: 11/09/2023 Year 2023 2022 2021 COUNTY Exemption Value $50,000 $50,500 $50,500 Taxable Value $738,116 $182,525 $175,738 SCHOOLBOARD Exemption Value $25,000 $25,500 $25,500 Taxable Value $763,116 $207,525 $200,738 CITY Exemption Value $50,000 $50,500 $50,500 Taxable Value $738,116 $182,525 $175,738 REGIONAL Exemption Value $50,000 $50,500 $50,500 Taxable Value $738,116 $182,525 $175,738 Previous OR Sale Price Book- Qualification Description Page 09/16/2022 $800,000 33394- Qua[by exam of deed 2403 17844 Sales which are disqualified as 09/01/1996 $0 3303 a result of examination of the deed 12/01/1991 $119,000 15329- Sales which are qualified 3841 04/01/1980 $130,000 10728 Sales which are qualified 1693 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp «.OPl Miami Shores Village \ Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax:(305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC 1 l ^ Z3-2A-j This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done):9720 BISCAYN E BLVD City: Miami Shores Village County: Miami Dade Zip Code: 33138 ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED Change disconnecting means: YES❑ NO ❑■ ARHI Sheet Attached: YES ■❑ NO ❑ Contract Attached: YES ❑■ UNIT BEING REPLACED DATA NEW UNIT TRANE MANUFACTURER TRANE TEM6AOC60 AHU or PKG. UNIT MODEL # TEM6BOC6OH51 4TTR6061C COND. UNIT MODEL # 4TTR506ON1 10 KW KW HEAT 10 KW 5 TON NOM TONS 5 TON AHU 50 CU 30 PKG 1) M.C.A AHU 50 CU 30 PKG AHU 60 CU 50 PKG 2) M.O.P AHU 60 CU 50 PKG AHU 60 CU 50 PKG 3)VOLTS AHU 60 CU 5OPKG PKG UNIT / / PKG UNIT 15.40 SEER2 EER/SEER 15.40 SEER2 YES NOX REPLACING DUCTS YES NOX YES NOX REPLACING THERMOSTAT YES NOX YES NOX NEW 4"CONCRETE SLAB YES NOX YES NOX NEW ROOF STAND YES NOX YES NOX NEW RETURN PLENUM BOX YES NOX 1. Minimum Circuit Ampacity (Wire Size): 8 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 60 3. Voltage of Circuit (206/240/480): 208/230 4. Size Disconnecting Means: 60 Contractor's Company Name. ALL YEAR COOLING & HEATING Phone: 954-799-0110 State Certificate or Regiaftition No.CAC0581 9 Certificate of Competency No. Signature 1&a__rfo"MrDate: 11 /9/2023 lQualifiers signature) (Revised02/24/2014) uV■�1 CERTIFIED° www.ahridirectory.or9 Certificate Product AHRI Certified Reference Number: 208782749 Date: 11-09-2023 Model Status: Active AHRI Type: RCU-A-CB (Split System: Air -Cooled Condensing Unit, Coil with Blower) Outdoor Unit Brand Name: TRANE Outdoor Unit Model Number (Condenser or Single Package) : 4TTR506ON1 Indoor Unit Model Number (Evaporator and/or Air Handler) : TEM6BOC6OH51+TDR Region: All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: On January 1, 2023, efficiency standards increased for central air conditioners. Beginning January 1, 2023, central air conditioners can only be installed in region(s) for which they meet the new regional efficiency requirements. The manufacturer of this TRANE product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 - 2017 with Addendum 1, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third parry testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 57500 SEER: 16.00 EER (A2) - Single or High Stage (95F) : 13.00 Rated as follows In accordance with the latest edition of AHRI 210/240 — 2023, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (AFu*— Single or High Stage (95F), btuh : 56000 SEER2 : 15.40 EER2 (AFUII) — Single or High Stage (95F) : 12.30 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Slopped' Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary m-rate. The new published rating is shown along with the previous (le. WAS) rating. The Department of Energy has published updated energy efficiency mettles for central air Conditioners and heat pumps. This publication reflects both the 1987 metric (SEER) and the 2023 metric (SEER2). Efficiency requirements are published at 10 C.F.R. 430.32(c). Please refer to www.AHRlnet.org for more information about updated energy efficiency metrics. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahridIrectory.org. TERMS AND CONDITIONS � RA' This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or In part, be reproduced; copied; disseminated; �..� entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's Individual, personal and confidential reference. AIR-CONDITIONING, HEATING. CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information for the model cited on this certificate ran be verified at www.ahridirectory.org, click on -Verify Certificate' link 11 make life bener- antl enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above, and the Certificate No., which Is listed at bottom right. ©2023Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 133440406133295243 �' ENGINEERING ENGINEERING EXPRESS® PRODUCT EVALUATION REPORT July 7, 2020 Application Number: FL 19588.3-R3 EX Project Number: 20-28643 Product Manufacturer: Trane US Inc Manufacturer Address: 6200 Troup Hwy Tyler, TX 75707 Product Name & Description: TRANE Condenser (Ground Mounted) Scope of Evaluation: This Product Evaluation Report is being issued in accordance with the requirements of the Florida Department of Business and Professional Regulation (Florida Building Commission) Rule Chapter 61 G20-3.005, F.A.C., for statewide acceptance per Method 1(d). The product noted above has been tested and/or evaluated as summarized herein to show compliance with the Florida Building Code Seventh Edition (2020) and is, for the purpose intended, at least equivalent to that required by the Code. Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or revisions. Substantiating Data; • PRODUCT EVALUATION DOCUMENTS EX drawing #20-28643 titled "A/C Unit Housing and Mounting Certification", sheet 1-1, prepared by Engineering Express, signed & sealed by Frank L. Bennardo, P.E. is an integral part of this Evaluation Report. TEST REPORTS Ultimate test loading structural performance has been tested in accordance with ASTM E330-02 and TAS 202-94 test standards per test report(s) #0708.01-15 by American Test Lab of South Florida, Inc. Signed and Sealed by Stephen W. Warter, P.E • STRUCTURAL ENGINEERING CALCULATIONS Structural engineering calculations have been prepared which evaluate the product based on comparative and/or rational analysis to qualify the following design criteria: 1. Minimum Allowable Unit Width 2. Maximum Allowable Unit Height 3. Minimum Unit Weight 4. Maximum Allowable Unit Surface Area 5. Clip Configuration and Anchor Spacing 6. Anchor Capacity for Various Substrates Maximum allowable roof -top heights for various installation wind speeds No 33% increase in allowable stress has been used in the design of this product. 160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH,, FLORIDA 33442 (954) 354-0660 1 (866) 396-9999 TEAM@ ENGINEERINGEXPRESS.COM ENGINEERINGEXPRESS.COM ENGINEERING Page 2 of 2 Trane US Inc — TRANE Condenser (Ground Mounted) Impact Resistance: Not applicable to this product. Wind Load Resistance This product has been designed to resist wind loads as indicated on the Product Evaluation Document (i.e. engineering drawing). Installation The product listed above shall be installed in strict compliance with the Product Evaluation Document (i.e. engineering drawing), along with all components noted therein. The product components shall be of the material specified in the Product Evaluation Document (i.e. engineering drawing). Limitations & Conditions of Use: Use of this product shall be in strict accordance with the Product Evaluation Document (i.e. engineering drawing) as noted herein. All supporting host structures shall be designed to resist all superimposed loads and shall be of a material listed in this product's respective anchor schedule. Host structure conditions which are not accounted for in this product's respective anchor schedule shall be designed for on a site -specific basis by a registered professional engineer. All components which are permanently installed shall be protected against corrosion, contamination, and other such damage at all times. This product has been designed for use within and outside the High Velocity Hurricane Zone (HVHZ). Respectfully, BE s i* 4 08/Od/2sglaNA4 �;� ��, Frank Bennardo, PE ENGINEERING EXPRESS® #PE0046549 I Cert. Auth. 9885 160 SW 12T" AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 (954) 354-0660 1 (866) 396-9999 TEAM@ ENGINEERINGEXPRESS.COM ENGINE ERINGEXPRESS.COM UNIT HO 'CERnFICS e4rX Yxli NG CERTIFICATION cup N •�`4M��'n XGM RE `j EW PERCUP Y 'y � •_ "BACKUP CLIP" ATTACHMENT SCALE: N.T.S. ISOM. LAYOUT A (1) BASE CLIP PER CORNER 1 SCALE: N.T.S. ^ Isom, D.R00• b 00.350' Q 6 C iJ i W OAO o RO.100' i E0.350' D0.250 eACRUPi RO.xsO- (ITS 0.2so•• los0 1-o.ler RO,25U' : a.00i U SO EENI L E0�x00 0.)ls' 0.032' T 0 9ASE TAR BRACKET 0.170' /{. XATENAL• 0.06'a IAL, PRE-"I GA"W"C'E0 IYP, STEEL E53101x03, PER 060 TX%. DAN- ROs30' TTP. aN .0601Xs10E MOII UNIE55 D oTXERHHU S=FIED PART ND A 0 C 0 E f dfi m!]oe6Fm dl 2.se Fs 4IF0 . an uC ! {I 01!]WNPJt LO L91 tM E93 3]! LW /. BASE TAB BRACKETS BRACKETS \ '1 / s M: N.T.S. HIR NWSING o.016' J.HD.178- 0.296"X " LONG NIPPLE BEAT 6.636• 0.396' SASEEPAH A/C HOUSING sfCl10N UNIT MODELS LAYOUT B �31(2) BASE CLIPS PER CORNER 1 SCALE: N.T.S. ISON. OA4S•0.004 ;2m- ROwm'(2K) f WITH CAONAK SURFACE CONVEn51GN. s OTHERWISE SPECIFIED. .030 THICK o.»e• amD- 0.0]u• m.Axs• ,OaS 0.239'� R0.030' 0.10o-T Ro.o d500• 0.190• WIDTH DTN� MAX � MA% 7 • n I`9A5' � Mq% r D ELEcra, Dq� I IxTKsM E01 1/ � J TS' HcvslxG ],xs ( MA% £ 6 CONNECTION LAYOUT A 1 sGrE: N.T.s. PLAK WE, r-WIDTH o a.3' �I p � 4.05' i�-�tiy-"✓N98 MAX • yp�L � � R0.060'(3%r o.310• /d eLrycTUIC ]] D S 0. 0.38 BACKUP CLIP- 1E4 ;;°��Tx 1 sCAIE: X.T.S. 7. MAX ATMuCARLE MDEEHL: CONNECTION LAYOUT B ]/I. Z/ZTNI. ROL ATTk Fny ATE. 1 lWE: x.T.S. KA. VIEPI RWA. LATVe. 1W0. ATxa.XnvZ. arryY Digitally signed ..t,1„IT;.,:>E.T:,:. 1 xHU-A;iiD �ro] by Frank RON KX R6 .. .D I Bennardo „ I Date:2020.08.31 10:23:02-04'00' GENERAL NOTES ANCHOR NOTES: afxN, KpwpmDRNNP�,HD- SW2i ��wxf GmT0. yN'xW LmxoR ussumlrxx+Wao. LxmNeoroxW..N: v.x,nlEM:]Rx ,R .. P m f]c]r x..•. s,.,.rs luel u.N..]m wee 3.m, ,••+-:PAXP pPLN wr MN In��°"�n.wc wmxa:x.,,x .0 mnv.e MN.H... HH 9`u...,De`G T xXutaxX .mxwswnai. x,R o]xlf rwis VISIT ECALC.1O128643 �0 m elan rN,E6ANYT0 TXfM'" TY-� xw MCuxDrt ,xrsoNceCEL-_JLiEi=N � Inx;newnp �Rescunw ALLOWABLE WIND PRESSURES FOR MULTIPLE BASE BRACKET AND UNIT HOUSING CONFIGURATIONS u mul_ eu rM MICR. DF.f THE.1. n ' DIVINATION ml J -IT HIM DUHH NE14M YN NR/ ENIHI]6IIM ]Z ]J IH 60 KI NRIXttRi 4YOVIA fEY / 9N1 Z ZIX IS.N IN WKI iYIC IA U]W]A TYeE%0l wrry 2RKw 3zesp .0 ]R lx NKr ___ E IYKIGttPRx umrtA NR/pI ANIX ILK IN ]9.JJ IN 9pgl TRZXTFK3 4YW]A r ] ZI.Z9p IJ.H IX Ail]IM TYIE 16 )1➢CI Ae 4 Z3ZL$awp aqKA u1uAYYmMdRl]A ESt/v .[AI mTSE'KEMR// n ETUDE my hRLRTriEt N "AID, Nm1)p qKI IN]YK] IA]drtE IYFE NI./ .A,N P.Mp .I.N ]N NMI nre w R TVFE A/N N.N IX 326Ew 29.9a IN __. NKF rYK l6TFEI 4MV]A "= TABLE DIRECTIONS: I. XNCT VEHXD UNrt siZf z SELECT APPuapE A..JT TIPE DEx mMlNxinOx a vtu]Im D. DTHI 3. NRSZE WITH THE INTENDED N ONSTPl1RYCNRE YTD OCEEMA vX ALLowaeLe wpo Pwsuxf IDRTHEDw,W KEH H,.,,A I. IIED WINO FPF55VRF91LR TITH RFr[ cexnnC4nOx m Lr mxeAs YNYSE UYDDTgl LI$TCD IN LPGL. UV wecxr. uE LE rt INE14M. 30x HE (OCHIATTH wEWM. I]0NI bw wa maLL 3i 95 a<IN m �J^�W 3w- wm- W waG k gg's e�=X$g g Ee99�90.�ge �gg a � �lil� nEE��eo 9 g�g8$ All Year Cooling ERIC MANDELL 9720 Biscayne Blvd Miami Shores, FL 33138 % (954) 629-5235 ESTIMATE ESTIMATE #90274-2 ESTIMATE DATE Nov 9, 2023 EXPIRATION DATE Nov 30, 2023 TOTAL $7,400.00 CONTACT US 4300 NW 124th Ave Coral Springs, FL 33065 f, (888) 820-8705 p servicedept@allyearac.com Service completed by: Rudy Pesci 5 Ton 14TTR5060N1000` 15.4 SEER(2) AHU TEM6BOC60H51S` 1.0 $8.100.00 $8,100.00 Condenser 1 45-1/8H x 34-1/4W x 37-1/4D AHU 57.4 x 23.5 x 21.13 AHRI 208782749 Warranties Compressor: 10Years Condenser:10Years Evap Coil: 10Years Parts: 1 OYears Labor: 3Years Ruud stage t-stat New return box Concrete slab Removal and Legal Disposal of Existing Unit. Reconnect existing duct copper drain and electric. Duct Cleaning 10kw heater Permit UV Light Kit 1.0 $500.OU $500.00 1.0 $350.00 $350.00 All Year Cooling I CAC058159 https://www.allyearcooling.com, 1 of 2 G24 / Standard Services subtotal: $8,950.00 Subtotal $8,950.00 Fpl Rebate - $150.00 New Customer Promo - $600.00 Discount - $300.00 Discount - $500.00 Total $73400.00 All Year Cooling I CAC058159 https://www.allyearcooling.com/ 2 of 2 Ron DeSantis, Governor Melanie S. Griffin, Secretary dbpr a STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD THE CLASS B AIR CONDITIONING CONTRACTOR HEREIN IS CERTIFIED UNDER THE PROVISIONS OF CHAPTER 489, FLORIDA STATUTES SMITH, THOMAS ARVID ALL YEAR COOLING & HEATING INC 1345 NE 4TH AVENUE FORT LAUDERDALE FL 33304 LICENSE NUMBER: CAC058159 EXPIRATION DATE: AUGUST 31, 2024 Always verify licenses online at MyFloridaLicense.com 0 + ,��fi^ .•,�. :f�. Do not alter this document in any form. TIL. jy -�'Y�t{yi1�LFr This is your license. It is unlawful for anyone other than the licensee to use this document. • - �'�` BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. -Lauderdale, FL 33301-1895 — 954-357-4829 VALID OCTOBER 1, 2023 THROUGH SEPTEMBER 30, 2024 DBA: Receipt #:183-650 Business Name: ALL YEAR COOLING & HEATING INC Business Typ e:REATING/AIRCONDITION CONTRACTI (CERTIFIED AIR CONDITIONING CONTRACTOR) Owner Name: THOMAS A SMITH /QUAL Business Opened:10/03/1996 Business Location: 4300 NW 124TH AVE State/County/CertlReg:CAC058159 FT LAUDERDALE Exemption Code: Business Phone: 954-566-4644 Rooms Seats Employees Machines Professionals 10 For Vending Business Only Numher of Mar_hinna— %1, 82»» r....... Tax Amount Transfer Fee NSF Fee Penalty --------.. -1 -- Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 0.00 27.00 1\GL;'Z.LpL r CU 2-1. 00 Packing/Processing/Canning Employees 0.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. Mailing Address: THOMAS A SMITH & GRETA B SMITH Receipt #WWW-22-00263896 4300 NW 124TH AVE Paid 08/07/2023 27.00 CORAL SPRINGS, FL 33065-7641 2023 .2024 BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-357-4829 VALID OCTOBER 1, 2023 THROUGH SEPTEMBER 30, 2024 DBA: ALL YEAR COOLING & HEATING INC Receipt#: 183-650 Business Name: Business Type' HEATING/AIRCONDITION CONTRACTR Owner Name: THOMAS A SMITH /QUAL Business Location: 4300 NW 124TH AVE FT LAUDERDALE Business Phone: 954-566-4644 (CERTIFIED AIR CONDITIONING CONTRA TOR) Business Opened:l0/c 1996 StatelCounty/CertlReg: CAC058159 Exemption Code: Rooms Seats Employees Machines Professionals 10 Signature For Vending Business Only llt�tmhar of 14Aa�l�inac• v..».�:».. r..»... Tax Amount Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.001 0.00 0.00 27.00 Receipt #WWW-22-00263896 Paid 08/07/2023 27.00 AC<> RV CERTIFICATE OF LIABILITY INSURANCE `...� DATE(MMNDmrYY) 11/10/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the pollcy((es) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER Alliant Insurance Services, Inc. 701 B St 6th FI San Diego CA 92101 CONTACT PHONE FAX • 619-238-1828 AIC No): 619-699-2100 ADDRESS: INSURERS AFFORDING COVERAGE NAIC # INSURER A: Main Street America Group, Inc L ce e ' OC36861 INSURED ALLYM-02 All Year Cooling and Heating Inc 4300 NW 124th Ave INSURER B: RetailFirst Insurance Company 10700 INSURER C :Main Street America Assurance 29939 INSURER D : Coral Springs FL 33065 INSURER E : ENSURER F : COVERAGES CERTIFICATE NUMBER:921069956 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE AODL SUBR POLICY NUMBER Map EFF POLICYEXP LIMITS A X COMMERCIAL GENERAL LIABILITY 71 CLAIMS -MADE I OCCUR 10,000 MPG0253X 9/5/2023 9/5/2024 EACH OCCURRENCE $1,000,000 DAMAGE TO RENTED PREMISES Ea occurrence $ 500,000 X MED EXP (Anyone person $10,000 PERSONAL & ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: POLICY JECTPRO a LOC OTHER: GENERAL AGGREGATE $ 2,000,000 PRODUCTS - COMP/OP AGG $ 2,000,000 $ C AUTOMOBILE LIABILITYCA00020884 ANY AUTO OWNED X SCHEDULED AUTOS ONLY AUTOS X HIRED X NON -OWNED AUTOS ONLY AUTOS ONLY 9/12/2023 9/1212024 COMBINED SINGLE LIMIT Ea accident $ 500,000 BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE Per accident $ UMBRELLA LIAB EXCESS LIAR OCCUR EACH OCCURRENCE $ HCLAIMS-MADE AGGREGATE $ DED RETENTION $ $ B WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANYPROPRIETOR/PARTNER/EXECUTIVE YIN OFFICER/MEMSEREXCLUDEDT (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below NIA 520-62495 1/31/2023 1/31/2024 XPER OTH- STATUTE ER E.L. EACH ACCIDENT $1,000.000 E.L. DISEASE - EA EMPLOYEE $1,000,000 E.L. DISEASE - POLICY LIMIT $1,000.000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, maybe attached If more space Is required) THOMAS A SMITH CAC058159 GRETA B SMITH CAC058160 TOM SMITH DEVELOPMENT II, INC. - EC13008936 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN MIAMI SHORES VILLAGE HALL BUILDING $ ZONING ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2ND AVENUE AUTHORIZED REPRESENTATIVE MIAMISHORES FL 33138 USA ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25 (2016/03) The ACORD name and logo are registered marks of ACORD