Loading...
RF-03-22-767Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address 672 NE 98TH ST, Miami Shores, FL 33138 Contacts Issue Date:04/14/2022 Parcel Number 1132060171780 Permit NO.: RF-03-22-767 Permit Type: Roof Work Classification: Tile Permit Status: Approved Expiration: 10/14/2022 NA Owner bruce & bruce, Inc. Applicant santiago martinez victor bruce 260 NE 95th ST, Miami Shores, FL 33138 370 NE 101st Street, Miami Shores, FL 33138 Mobile: 7737930782 santiagomartinezl@gmail.com Business: 3053105030 vb@b2-ai.com Other: 3053105030 F. ANTHONY GERACI 290 NW 161 ST, MIAMI, FL 33169 Business: 3059492627 tgeraci8@gmail.com Mobile: 7863010887 Ins e. on Re uests Description: TILE ROOF ON ADDITION ONLY Valuation: $ 24,750.00 0' Total Sq Feet: 2,300.00 - i la. Fees Amount Application Fee - Other $50.00 CCF $15.00 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $5.00 Roofing Fee $250.00 Scanning Fee (Manual) $12.00 Technology Fee $7.50 Total: $347.00 Payments Date Paid Amt Paid Total Fees $347.00 Cash 03/25/2022 $50.00 Credit Card 04/14/2022 $297.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I 9pAify that al the regoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction an zoning._ Fpth or T I auth2oze the above named contractor to do the work stated. Authorized Signature: Owner / k Pktllca)t / Contractor / Agent Date April 14, 2022 Page 2 of 2 Miami Shores Viflag p Building Department AR252022 • • 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 t Tel: (305) 795-2204 Fax: (305) 756-8972 By INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 BUILDING Master Permit No. C - 0 'Z �}��-SZz PERMIT APPLICATION Sub Permit No. I Y-na 2,2 ` -� ❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION Q EXTENSION ❑RENEWAL PLUMBING MECHANICAL PUBLIC WORKS CHANGE OF CANCELLATION ❑ SHOP i DRAWINGS 6 A. 1l ,p `CONTRACTOR JOB ADDRESS: C� l� City Miami Shores County: Miami Dade Zip: Folio/Parcel#: /I 320 6 D � �" { / 9-90 Is the Building Historically Designated: Yes NO occupancy Type: - Load: Construction Type: C0 Flood Zone:. BFE: FFE: OWNER: Name (Fee Simple Titleholder): d :H C G— Phone#:. Address,:- 4;200 ly'e- /c:5 S� City:State: Zip: 3 3 Tenant/Lessee Name: `� Phone#: Email: CONTRACTOR: Company Name: (-Den Address: Z�c? &ILJ City: ' Qualifier Name: �/'v ' 1 o State Certification or Registration #: We / !.)[0/ 30 /, ®Fly q— Phone#: ?-S to zz / /e) ,R ..; 7 of Competency #: DESIGNER: Architect/Engineer: N Phone#: 'Address: •�,,�^ City: State: -Zip: Value of Work for this Permit: $ L'f : ! •7 Q Square/Linear Footage of Work: 2— 3 ©©. `�' F .Type of Work: ❑ Addition ❑ Alteration ❑ New - ElRepalr/Repllace I El Demolition / Description of Work: � I /e RUO f 0/'j 6 6 Q 1 �T 1 co - 0"LPL•/ 1 Specify color of color thru tile: L% Le _ /-rrr,i o i A O Ai,3�j n�&) U Submittal Fee $ Permit Fee $ 2 00 CCF $ .�CO/CC $ Scanning Fee $ 1 2. 00 Radon Fee $ Ors DBPR $ Notary $ `— Technology Fee $ Training/Education Fee $ K�— 00 Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lenders Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... ,OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO, OWNER: .YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with on estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a relnspection fee will be charged Signature Signatures OWN FtorAGENT CONTRACTO The foregoing instrument was ackn wledged before me this \Z' daayof+11YV1✓\+\tTr �.20 ZZ,by p17 �pw�i�tA 7 I�pp�.Qf•'Y\ (J. \Yhlis personally known to me or or who has produced �C• LAC• L •1>_ L as identification and who ALBERT SEARA Notary Public State of Florida Commission # GG 304563 �y Comm. Expires Feb 24, 2023 through National Notary Assn. Print: r Seal: The foregoing instrument was acknowledged before me this Z Z day of CAK'A,.- CrV, 20 Z-2 by Qhm s orqnnnllv knnwn to me or who has pro uced as identificatidh and who did take an oath. NOTARY P40LIC: — —� Print: Seal: 4yr ny., ALBERT SEARA • y;�S Notary Public - State of Florida \ ♦ 4• 'ht a;Commission# GG 304563 through rrrrrrsrraaraararrrrasxrrrsrraaarrrrrrrrrrrrsrssrrssrsrrsssssssrararaaarraraarrrrwrrssrsrrssrrrrrrrrrrrrrrr APPROVED BY ����Plans Examiner Zoning Structural Review (Revised02/24/2014) Clerk Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Issue Date: 10/18/2022 2- 11,97,70MNATAt11150*450W II Permit Type: Revision Work Classification: Building Permit Status: Approved Expiration: 04/18/2023 Parcel Number Project 672 NE 98TH ST, Miami Shores, FL 33138 1132060171780 <NONE> Contacts NA Owner design home remodeling corp Applicant santiago martinez Tony GERACI 260 NE 95th ST, Miami Shores, FL 33138 290 nw 161 st 161 st, miami, FL 33169 Mobile: 7737930782 santiagomartinezl@gmail.com Business: 7863010857 tgeraci8@gmail.com Mobile: 7864878241 design home remodeling corp Contractor RMQ BUILDERS LLC Agent Tony GERACI RAMON MARTINEZ 290 nw 161 st 161 st, miami, FL 33169 717 PONCE DE LEON BLVD. SUITE 225, CORAL GABLES, FL 33134 Business: 7863010857 tgeraci8@gmail.com Mobile: 7863675517 ramonc@rmqconstruction.com Mobile: 7864878241 Description: Change of tile adhesive from file bond to ICP Valuation: $ 100.00 Inspection Requests: AH 160 305-762-4949 Total Sq Feet: 2,300.00 i Fees Amount Payments Date Paid Amt Paid Revision: Minor Change of Plans $60.00 Total Fees $60.00 Credit Card 10/18/2022 $60.00 Total: $6D.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOLwork. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named�° ntracto do the work stated. �C erg.► Oi ► f) ► I q I Authorized Signature: Owner / Applicant / Contractor / Agent October 18, 2022 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC H ROOFING ENTERED O C T 7 2022 By: 2 FBC 20 Master Permit No. RC-03-21-522 Sub Permit No. RF-03-22-767 (] REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 672 ne 98 st City: Miami Shores County Miami Dade zip: Folio/Parcel#: 1132060171780 is the Building Historically Designated: Yes NO XX Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Santiago Martinez Phone#:7737930783 ArIA'0«.260 ne 95 st City: Mia Shores FI State: _ Tenant/Lessee Name: NA Email: NA M 33138 CONTRACTOR: Company Name: Designhome Remodeling Phone#: 7863010857 Address: 290 nw 161 st City: miami State: FI Zip: 33169 Qualifier Name: Anthony Geracl Phone#: 7863010857 State Certification or Registration #: ccc057409 Certificate of Competency #: DESIGNER: Architect/Engineer: victor Bruce Phone#: 3053105030 Address:370 ne 101 st city: mia Shores State: Zip: 33138 Value of Work for this Permit: $106 square/Linear Footage of Work: 2300 Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ lace Re air Re p / p ❑Demolition Description of Work: REVISION of foam adhesive for the attachment Specify color of color thru tile: Submittal Fee $ Scanning Fee $ Technology Fee Structural Reviews $ Permit Fee $ CCF $ Radon Fee IS _ DBPR __ Training/Education Fee $ CO/CC $ — Notary Double Fee $. Bond $ TOTAL FEE NOW DUE $ dovised02/24/2014) Bonding Company's Name (if applicable) na Bonding Company's Address na city na State na Mortgage Lender's Name (if applicable) na Mortgage Lender's Address na city na State Zip na Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant., As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is Issued. In the absence of such posted notice, the inspection will not be approved and a reinspedion fee will be charged Signature f' O ER or AGENT The foregoing instruments as acknowledged before me this Q�d— ayof &TOber 20 2Z .by ft.d—BLJ�A 41 Mfiols�ersonallyknownto me or who has produced DC- as identification and who did take an oath. Signature CO CT The foregoing instrument was acknowledged before me this 7 day of October 22 2D by anthony geraci whclis ersonally known o me or who has produced fJ A as identlficat n a ho did take an oath. NOTARY P LIC q— ALBERT SEARA Notary Public State of Florida a Sign: '. Commission # GG 304563 My Comm. Expires Feb 74. 2023 hrou h National Notary Assn. Print: Albert S a Seal: APPROVED BY V1 7Ir1plans Examiner Zoning Structural Review (Revised02/24/2014) Clerk Florida Building Code 7th Edition 2020 HIGH VELOCITY HURRICANE ZONE UNIFORM ROOFING PERMIT APPLICATION SECTION E (Tile Calculations) For moment based file systems, chose either Method for 2. Compare the values for Mr with the values from Mn If the Mr values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based yTil�e Calculatio s Per RAS 127" ( Zone 1: �) x .nI L = / 9, 7 ) - Mg: 7- Mr 1 ( Zone 2e:•- 1 x 1 2-7 = ) - Mg: iiz (Zone2n: xILZL22�='ZIMg:!�F-b% =Mr2n (Zone 2r:-%i xX-12 _ )-Mg:?•07 =Mr2r (Zone 3e:-lZZ al ( )-Mg: 7.07 =Mr3e (Zone 3r:- � _-7xA1� 9Z(•P -Mg: r�0)=1VIr3r /Z?� Product Approval Mf. e) < Product Approval Mf! © r 41 c 1 Product Approval Mf: 410,11 2 • Product Approval Mf: , ZG • b y Product Approval Mf: jq�Ul Product Approval Mf: 0 Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From Table Below: NOA Mr Required Moment Resistance* Mean Roof Height Roof Sloe 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 5:12 30.4 28.4 32.2 30.1 33.8 31.6 35.1 32.8 37.3 34.9 6: 1 29.4 30.5 32.4 7: 1 27.1 1 28.2 1 30.0 This table must be used in conjunction with a list of moment based the systems endorsed by the Broward County Board of Rules and Appeals. For uplift based the systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (Zone 1: x 1:—= _ x w:=___-_) - w: x cos r: _ (Zone 2e: x 1: = _ x w:=___) - w:_ x cos r (Zone 2e:_ x 1: = _ x w:=_) - w:_ x cos r (Zone 2r._x1: =_xw _)-w:xcosr:_ (Zone 3e:_ x 1: = _ x W.=----) - w:_ x cos r (Zone 3r:_ x 1: _ _ x w:=___) - w:_ x cos r Where to Obtain Information = Frt: NOA F' = Fri NOA F = Fa.NOA F _= Far NOA F' = Fr3e NOA F' = Fr3r NOA F' Description Symbol Where to Find Design Pressure ZONE i,2ean,2r,3c,3r RAS 127 Table 1 or by an engineering analysis r azed b a P.E. based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier 2, NOA Restoring Moment due to Gravity M NOA Attachment Resistance Mr NOA Required Moment Resistance M. Calculated Minimum Attachment Resistance F' NOA Required Uplift Resistance Fr Calculated Average Tile Weight W NOA Tile Dimensions L = length W = width NOA All calculations must be submitted to the Building Official at the time of permit application. 4bout Us - Number nhb -: Products - Specifiers - Resources - Technical - it :flex o 0 �:,�a ..oar• ©®-� Category Standard Select Description Hues of Dark Brown. Black Streaks Ref Aged Ref.(3 yr) EMI Aged EMl.(3 yr) SRI Aged SRI(3 yr) CRR 0.13 0.17 094 a92 12 16 091" `:. T24 IWI i �4 S I�.o res Ffa KIF . • . COUNTY DEPARTMENT OF REGULATOR BOARD AND CODE ADMDVISTR NOTICE OF ACCEPT Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 Miami Shores Village Zoning Dept. Building Dept._ Subject to compliant MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Low Profile Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This NOA revises NOA #21-0315.03 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. NOA No. 21-0420.08 M1 :4 INUN A.A Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This approves a new roofing system using "Low Profile Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Applicant Dimensions Low Profile Lenght = 17" Concrete Tile Width =12 '/a" Thickness = V? Test Specifications Product Description TAS 112 Flat profile concrete roof the equipped with two Type 3a nail holes. For adhesive set, direct deck or Class III battened nail -on applications. Trim Pieces Lenght = varies TAS 112 Width = varies varying thiclaiess 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyse& AH-160 TILE BONDTM Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Touch `N Seal 9tormBone 2 Two- Two component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive Touch `N Seal StormBone One One component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive 2.2 MANUFACTURIN(T LOCATION 2.2.1. Sumterville, FL Accessory trim, concrete roof pieces for use at hips, rakes and ridges. Manufactured for each tile profile. Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. DuPont de Nemours, Inc. DAP Foam, Inc. DAP Foam, Inc. NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 2 of 9 2.3 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies ERPF-001-02-01 TAS 112 Aug. 2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102(A) 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail -On) P0402 Withdrawal Resistance Testing of screw vs. Sept. 1993 smooth shank nails Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail -On) P09647-01 Wind Tunnel Testing Aug. 1994 TAS 108 (Mortar Set) The Center for Applied 94-084 Static Uplift Testing TAS 101 (Mortar Set) May 1994 Engineering, Inc. 25-7094-(2, 5, & 8) Static Uplift Testing TAS 102 Oct. 1994 25-7183-(5 thru 6) Static Uplift Testing TAS 102 Feb. 1995 25-7214-(1, 5, & 8) Static Uplift Testing TAS 102 March, 1995 25-7487-2 Static Uplift Testing TAS 102 Dec. 1995 25-7496-(1 & 4) Static Uplift Testing TAS 102 Dec. 1995 25-7804-6 Static Uplift Testing TAS 102 Sep. 1996 Celotex Corporation Testing 520109-1 Static Uplift Testing TAS 101 Dec. 1998 Service 520111-4 Static Uplift Testing TAS 1.01 Dec. 1998 520191-1 Static Uplift Testing TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier Sep. 2006 Calculations Restoring Moments Due to Gravity Sep. 2006 ATL of South Florida RT0317.02-21 TAS-112 03/27/21 PRI Construction Materials DAPF-001-02-13 Static Uplift Resistance Testing TAS 1 Ol 11/30/17 Technologies DAPF-004-02-01 Static Uplift Resistance Testing TAS 101 07/09/18 DAPF-004-02-02 Static Uplift Resistance Testing TAS 101 07/09/18 NEMO ETC, LLC 4c-DPBS-20- TAS 101 12/17/20 LSOTMOLD.R1 PRI Construction 2002T0003.07 TAS 101 11/09/20 Technologies NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date., 09/02/21 Page 3 of 9 3 LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 shall be required, refer to applicable Building Code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami Dade County Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable Building Code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code Rule 61 G20-3 of the Florida Administrative Code. 4 INSTALLATION: 4.1 Eagle Roofing Products LLC Low Profile Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight-W (Ibf) Length-1(1t) Width-w (ft) Low Profile Concrete Tile 11.4 1.42 1.03 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Applicati n Low Profile Concrete Tile 0.301 0.278 Table 3: Restoring Moments due to Gravity - Mg (ftN Tile Profile 2" & 311:12 491:12" 5":12" 6":1 7":12" YN or greater Low Profile Concrete Tile _ Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Dire Dec Battens Direct Deck N/A 7.71 7.37 7.59 7.22 7.44 7.05 —7.21 6.86 7.07 NOA No. 21-0420.08 MtaMikDE COUNTY Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min.19132" plywood) Battens Low Profile Concrete Tile 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 50.3 65.5 48.3 1. Installation with a 4" the headlap and fasteners are located a min. of 2Y2"from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mt (ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application' Minimum Attachment Profile Resistance Low Profile Concrete Tile TILE BOND W Roof Tile Adhesive 632 TILE BOND TM Roof Tile Adhesive 653 ICP Adhesives Pol sett/ AH-160 31.34 Touch N Seal StormBond® 2 1095 Touch N Seal StormBond® (one component) 606 1 See manufactures component approval for installation requirements. 2 Medium paddy weight of 8 grams per paddy of TILE BOND rm Roof Tile Adhesive. 3 Medium paddy weight of 16 grams per paddy of TILE BOND TM Roof Tile Adhesive. 4 Medium paddy weight of 8 grams per paddy of Polyset@ AH-160 5 Medium paddy weight of 8 grams per paddy of Touch `N Seal StormBond ® 2 6 Medium paddy weight of 18 grams between tile and underiayment, paddy weight of 10 grams on overlap of tile of Touch `N Seal StormBond ® one component) MlAMMADE COUNiY T...� NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 5 of 9 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Tile Application' Minimum Attachment Profile Resistance Low Profile Concrete Tile ICP Adhesives Polyset® AH-160 / 118.91 _ ICP Adhesives Pol set®AH-160 40.4 1 Touch N Seal StormBond® 2 7310 Touch N Seal StormBond® 2 4411 .7 See manufactures component approval for installation requirements. 8 Large paddy weight of 45 grams of Polyset® AH-160. 9 Large paddy weight of 24 grams of Polyset® AH-160. 10 Large paddy weight of 45 grams of Touch 'N Seal StormBond ® 2 11 Large paddy weight of 24 grams of Touch 'N Seal StormBond ® 2 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Low Profile Concrete Tile Mortar Set12 43.9 12 Tile-Tite Roof Tile Mortar. 5. LABELING: All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved", EA GL Evil�� FLORIDA (LOCATED ON UNDERSIDE OF TILE) m EAGLE FL (LOCATED ON FRONTSIDE OF TILE) MIAMI•DADE COUNTY NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 6 of 9 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the installation of this system. A WING Low Low PROFILE ROOF TILE w P NOA No. 21-0420.08 .xpiratlon Date: 10/05/26 Approval Date: 09/02/21 Page 7 of 9 Low PROFILE ROOF TILE LOW PROFILE ROOF TILE V... NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 8 of 9 LOW PROFILE ROOF TILE END OF THIS ACCEPTANCE MIAM4DADE COUNTY NOA No. 21-0420.08 . • • • , Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 9 of 9 Florida Building Code 7tb Ed on 2020 d I ffiG AT SECTION E (Tile Calculations) • �� For moment based tile systems, chose either Method for 2. Compare the values for Mr with the values from Ail!If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculatio s Per RAS 127" (Zone 1- y � ( x _ - ) - Mg: - Mr 1 (Zone 2e:•-'ii x1.27N = ) - Mg: =Mr2e (Zone2n: 7�i' x]=21,t'$)-Mg: - =Mr2n (Zone2n -%1 x1 17:� =1� -Mg: 7.07 =Mr2n (Zone 3e:-IZZ x7 3 / )-Mg: 7•07 =Mr3e ! Zone 3r: - i Y x X = KL� - Mg: '7--07 = Mr3r iZ 7� Product Approval Mf: Fq Product Approval MP 410 , �7[ Product Approval Mf: 1 Z fy Product Approval Mf*L Zb• k4 Product Approval Mf: L, I Product Approval Mf: 0 : Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From Table Below: NOA Mr Required Moment Resistance* Mean Roof Height Roof Sloe 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 312 32.2 34.4 36.0 37.4 39.8 4:12 5:12 30.4 28.4 32.2 30.1 33.8 31.6 35.1 32.8 37.3 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 282 30.0 This table must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For uplift based the systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (Zone,: x 1: _ x w:=_____) - w:_ x cos r: = Frt: NOA F' (Zone 2e: Is 1: _ x w:=____) - w: x cos r : = Fr7s NOA F' (Zone 2n:, x L = _ x w --_) - w:_ x cos r : = Fn NOA F', (Zone 2,: x l: = x w:=_) - w: x cos r : = Far NOA F' (Zone 3e:- x 1:-= _ x w:=---) - w:_ x cos r : = Fr3n NOA F' (Zone 3r._ x ).--= _ x w:=___) - w: x cos r : = 17,3r NOA F'_ Where to Obtain Information Description Symbol Where to Find Design Pressure ZONE 1,2c,2n,2r,3g3r RAS 127 Table 1 or by an engineerin prepared by a CE ent Mean Roof Height H Job Site Villag lng at Roof Slope 0 Job Site ' _ - Dept. Dat Aerodynamic Multiplier 7. NOA ullding Dep c , 1, a Restoring Moment due to Gravity M NOA Subje ley aAty nd reg Attachment Resistance Mf NO an Re uired Moment Resistance M. Calculated Minimum Attachment Resistance F' NOA Required Uplift Resistance Fr Calculated Average Tile Weight W NOA Tile Dimensions L = length W = width NOA All calculations must be submitted to the Building Official at the time of permit application. Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County Section A (General Information) Master Permit Number: / Process Num r."��2- '9 6=� Contractor's Name: D e� 5 / 4/U �/d s?�1 P Job Address: ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile J 1"pTTcTlill ❑ Metal Panel/Shingles MAR 2 5 AR ROOF TYPE ❑ Repair ❑ Maintenance ❑ Mortar / AAi1ZSNe Set ve ❑ Wood Shinglev/Shakes " ROOF SYSTEM INFORMATION ❑ Reroofing .. . „17 Recovering Low Slop rea (ftz) Steep Sloped Roof Area (ftz) I (ftz✓� V Are there ents on the roof? © Yes O No If Yes what type? O Natural LPX Is there an existing roof top Solar System? O Yes O No If yes will it be reinstalled? O Yes O No Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. A M 0r*3LOY el , tk_� Ty 4 >>r771 Miami Shor4& Zoning Dept. Date Building Dept. Date-3t�4 SUb)eCt o� ct ompTance wi a e erd1- State and County rules and regulations. Permit# • Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County Section E (Tile Calculations) For Moment based tile systems, choose Method 1. Compare the values for M,with the values from Mf. If the Mf values are greater than or equal to the M, values for each area of the roof, then the tile attachment method is acceptable. Method 1• " Moment Based Tile Calculations per RAS 12r Enter positive uplift pressures when using this _table �.3.... 71 .0.(Zonel:0�(7)—Mg:�� =MnZ�PdApprova..� ...... (zone2e;�x] L=r9'7/ )—Mg: ,c7=Mo.JZ.7� ProductApprgva:WO' (-t7�'•, .••••• ( Zone 2n:7,8 x � �' G`c{�) Mg:! = Mr2" 14to L,/Product Appro% P[ fl • • • (Zone 2r.2� x) z?��yy = /j—Mg: =Mr2r 1Z,?71 ProductApprovaCM* •• •��•� _ ZZ I a 7� a (Zone3e: x = )—Mg:=Mr3:[.�i * ProductAppra%Wryrf LQ3 •••••• (Zone3r: _ x1to5 ,U =' rj—Mg: .C? =Mo. . +bI Product Approval W..* ��•�.. .. Tile attachment method: Alternate Tile attachment method: For Uplift Based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values for each area of the roof, then the tile attachment method is acceptable. Method 3• "Uplift Based Tile Calculations per RAS 127" (Zone 1: x L = x W = ) — (w) x cos 8 ) = Fn Product Approval F': (Zone 2e: x L = x W = ) — (w ) x cos B ) = Frz Product Approval F': (Zone 2n: x L = x W = ) — (w) x cos 0 ) = Frzo Product Approval F': (Zone 2r: x L = x W = ) — (w) x cos 0 j = Fr2r Product Approval F': (Zone 3e: x L = x W = ) — (w) x cos B ) = Fr3. Product Approval F': (Zone 3r: x L = _ x W = ) —(w) x cos 0 ) = Fr3, Product Approval F': *Method 2 "Simplified Tile Calculations" only applicable in Broward County. Where to obtain Information Description Symbol Where to Find Design Pressure Zones 1, 2e, 2n, 2r,3e, 3r From the applicable Table in RAS- 127 or be an engineering analysis prepared by a PE based upon ASCE 7 Mean Roof Height H lob Site Roof Slope 0 lob Site Aerodynamic Multiplier ), Product Approval / Notice of Acceptance Restoring Moment due to Gravity M Product Approval / Notice of Acceptance Attachment Resistance Mf Product A proval / Notice of Acceptance Required Moment Resistance M, Calculated 'r Minimum Attachment Reslstance F' Product Approval / Notice of Acceptance Required Uplift Resistance F, Calculated Average Tile Weight w Product Approval / Notice of Acceptance Tile Dimensions LmLength W= Width Product Approval / Notice of Acceptance All calculations must be submitted to the Buildin Official at the time of permit application. Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County Section D (Steep Sloped Roof System) Roof System Manufacturer: Product Control Number: G/ — Minimum Design Wind Pressures, From Applicable RAS 127 Table or Calculations: Zonel: Zone 2e: Zone2n: Q�lZone 2r T Zone 3e d one 3*r?,— 7 Slope Range: Q>_ 2:12 to 5 4:12 0> 4:12 to < 6:12 40> 6:12 to:512:12 • • . �3> Roof Shape: OtAll Hip Roof 0 Gable Roof or Partial GablerMip'Roofy'. Deck Type: 3 Roof EFa Ridge Ventilation? 1 Underlayment Type: Insulation: *41 ])-ZZ(p -i;t:7 &C Tv v Fire Barrier: I K) Fastener Type & Spacing: Cap Sheet Type:`A Mean Roof Height: y Cap Sheet Attachment: r Roof Covering: F I A+ Drip Edge Type & Size: 3 3 Cp A I V/ Ili- -JPJ s "'i is a /// o�� • MIMI®-MIAMI-DADE COUNTY E PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 SCOPE: .... This NOA is being issued under the applicable rules and regulations governing the use of construction irfatefials. TkC • •; documentation submitted has been reviewed and accepted by Miami -Dade County RER-Pl6avi;Control Seotion to be•._ used in Miami -Dade County and other areas where allowed by the Authority Having Jurisds Ki (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County kjpduct Grontrol•Section ' (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve tli"ght to 1gavp this prgc n; or material tested for quality assurance purposes. If this product or material fails to perform &the accepted manner• tbe.. manufacturer will incur the expense of such testing and the AHJ may immediately revoke,:ntglify, or suspend the use .' of such product or material within their jurisdiction. RER reserves the right to revoke this 'acceptance, If it is. .... determined by Miami -Dade County Product Control Section that this product or material fails-6-meet the Nquiretrow".; of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Low Profile Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #21-0315.03 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigers. . APPROVED NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This approves a new roofing system using "Low Profile Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. °°°°° ° 000000 2. PRODUCT DESCRIPTION: Manufactured by Test Aimlicant Dimensions Specifications Low Profile Lenght = 17" TAS 112 Concrete Tile Width =12 '/a" Type 3a Thickness = V? Class III Trim Pieces Lenght = varies TAS 112 Width = varies varying thickness 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BONDTM Roof Tile Adhesive Product Descriation Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Touch `N Seal StormBone 2 Two- Two component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive Touch `N Seal StormBone One One component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive 2.2 MANUFACTURING LOCATION 2.2.1. Sumterville, FL ° ° ° ° °° ° ° ° ° 0° ° ° ° °°°°°° °° °° °°°°°° °°°°°° ° ° ° R�®duct ° °°°°°° ° ° Deation : °°°° °°°°° °°°°°° ° ° Flat profile concrete z9 f rile equjgp;a withotwo o nail holes. For adhesbve set, direct deck or ° ° ° battened nail -on applications. ° ° ° ° ° ° ° : ° ° ° ° ° ° ° ° ° ° ° ° Accessory trim, conMete;oof Oftee for use at°°°° hips, rakes and ridges. Manufadtured for each tile profile. Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. DuPont de Nemours, Inc. DAP Foam, Inc. DAP Foam, Inc. NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 2 of 9 2:3 EVIDENCE SUBMITTED: Test Aaency Test Identifier Test Name/Report Date PRI Asphalt Technologies ERPF-001-02-01 TAS 112 Aug. 2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102(A) 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail -On) P0402 Withdrawal Resistance Testing of screw vs.0 ... kept. 1993 smooth shank nails°° .-0 0000 000000 Letter Dated Aug. 1, Wind Tunnel Testing ° 0 ° Aug. 1994 1994 O TAS 108 (Nail -On),::::: :° e 000000 P09647-01 Wind Tunnel Testing.. , o ° O Aug. 1 f94° ° o TAS 108 (Mortar Se� 00 O O O 0 0000 00000 0 0 The Center for Applied 94-084 O O O O O O O O O O Static Uplift Testing TAS 101 (Mottar Set) ° O O O A° 0 0 0 :0: O ° May 1994° o ° Engineering, Inc. 25-7094-(22 5, & 8) Static Uplift Testing TAS f0l ; ° Oct. 19940, 25-7183-(5 thru 6) Static Uplift Testing TAS 10? ° o ° O oFeb. 1005 ° ° o 25-7214-(1, 5 , & 8) Static Uplift Testing TASA02 0 0 . o March, 1995• e 25-7487-2 Static Uplift Testing TAS 102 e ° e •1bec. 1995 25-7496-(1 & 4) Static Uplift Testing TAS 102 Dec. 1995 25-7804-6 Static Uplift Testing TAS 102 Sep. 1996 Celotex Corporation Testing 520109-1 Static Uplift Testing TAS 101 Dec. 1998 Service 520111-4 Static Uplift Testing TAS 101 Dec. 1998 520191-1 Static Uplift Testing TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier Sep. 2006 Calculations Restoring Moments Due to Gravity Sep. 2006 ATL of South Florida RT0317.02-21 TAS-112 03/27/21 PRI Construction Materials DAPF-001-02-13 Static Uplift Resistance Testing TAS 101 11/30/17 Technologies DAPF-004-02-01 Static Uplift Resistance Testing TAS 101 07/09/18 DAPF-004-02-02 Static Uplift Resistance Testing TAS 101 07/09/18 NEMO ETC, LLC 4c-DPBS-20- TAS 101 12/17/20 LSOTM0l.D.R1 PRI Construction 2002T0003.07 TAS 101 11/09/20 Technologies NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 3 of 9 3 LINIITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 shall be required, refer to applicable Building Code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade County Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. .... 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall bt ir4Cgmplianee-with .... applicable Building Code. .' .... .. .. ....:. 3.7 All products listed herein shall have a quality assurance audit in accordance with tho FQiida Building Code $ule 61 G20-3 of the Florida Administrative Code. ...... • • : ""' 4 INSTALLATION: .. .. . ...... 4.1 Eagle Roofing Products LLC Low Profile Flat Concrete Roof Tiles and its componEt's's 111 be installed in strict, compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. , 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length-1 (ft) Width-w (ft) Low Profile Concrete Tile 11.4 1.42 1.03 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Application Low Profile Concrete Tile 0.301 0.278 Table 3: Restoring Moments due to Gravity - M8 (ft-lbf) Tile Profile 2" & 3":12 4":12" VAT' VAT' 7":12" or greater Low Profile Concrete Tile Battens Direct Deck Battens I Direct Deck Battens I Direct I Deck Battens I Direct I Deck Battens Direct Deck N/A 7.71 7.37 7.59 7.22 7.44 7.05 .7.27 6.86 7.07 NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbq for Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132" plywood) (min. 19132" plywood) Low Profile 2-10d Ring Shank Nails 30.9 38.1 17.2 Concrete Tile 1-10d Smooth or Screw 7.3 9.8 4.9 Shank Nail 2-10d Smooth or Screw 14.0 18.8 7.4 Shank Nails 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nail Field Clip) 1-10d Smooth or Screw 19.0 19.0. ....•22.1 „,,, Shank Nail Eave Clip) '..' : 2-10d Smooth or Screw 35.5 35.5...... ..'.:34.8.... Shank Nails(Field Clip) •••:•• 2-10d Smooth or Screw 31.9 31.9 • • • • , 32.2. Shank Nails EaveClip) •••• •••••• ...... . .. ..... 2-10d Ring Shank Nails' 50.3 65.5'•" '" •48.3...... 1. Installation with a 4" the headlap and fasteners are located a min. of 21/21rom head of i e.• : ", Table 5: Attachment Resistance Expressed as a Moment Mf M Jbtx for Two Patty Adhesive Set Systems Tile Tile Application' Minimum Attachment Profile Resistance Low Profile Concrete Tile TILE BOND Tm Roof Tile Adhesive 632 TILE BOND Tm Roof Tile Adhesive 653 ICP Adhesives Pol set® AH-160 31.34 Touch N Seal StormBond® 2 1095 Touch N Seal StormBond® (one component) 606 1 See manufactures component approval for installation requirements. 2 Medium paddy weight of 8 grams per paddy of TILE BOND TA0 Roof Tile Adhesive. 3 Medium paddy weight of 16 grams per paddy of TILE BOND TM Roof Tile Adhesive. 4 Medium paddy weight of 8 grams per paddy of Polyset® AH-160 5 Medium paddy weight of 8 grams per paddy of Touch 'N Seal StormBond 12 6 Medium paddy weight of 18 grams between tile and underlayment, paddy weight of 10 grams on overlap of file of Touch 'N Seal StormBond ® one component) NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 5 of 9 6: BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the installation of this system. I PROFILE DRAWING LOW PROFILE ROOF TILE LOW PROFILE ROOF TILE NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 7 of 9 LOW PROFILE ROOF TILE LOW PROFILE ROOF TILE ...... • .... ...... NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 8 of 9 ->� "*4�� LOW PROFILE ROOF TILE END OF THIS ACCEPTANCE 0000 0 0 oeoo ooeooo 0 0 00 00 ooe000 0 0 0 0 0 0 0 0 0 0 00 0 0000 0 0 00oo 0 0 0 0 0 00 00 0 00 0 0 0 0 0 oe 0 000 0 0 0 00 0 0 00 0 0 o e 0 00 00 0 0 0 0 0 00 000000 i o 0 0 000000 0 0 000000 0 0 ooeoo 0 0 00000 000000 0 0 0 0 e e o e e 0 0 000eoo e O NOA No. 21-0420.08 Expiration Date: 10/05/26 Approval Date: 09/02/21 Page 9 of 9 MI®' MIAMI-DARE COUNTY e PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) wmy ndamldade.my/economy DuPont de Nemours, Inc. 974 Centre Road Chestnut Run Plaza 721-2246 Wilmington, DE 19805 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of cons4ruct;on materials. The ...... documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdictt(W CAW). • • • • • • % This NOA shall not be valid after the expiration date stated below. The Miami -Dade County P,roduej Congo! Section " (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the tV t to have th -product or material tested for quality assurance purposes. If this product or material fails to perform iri Widcepte4 firaVl*r, the*' manufacturer will incur the expense of such testing and the AHJ may immediately revoke, moaifX *or suspen8 the use of such product or material within their jurisdiction. RER reserves the right to revoke this acgeptange, if it�q • , determined by Miami -Dade County Product Control Section that this product or material fails,to meet the tegllhftents, of the applicable building code. : .... • This product is approved as described herein, and has been designed to comply with the Florida Building tc'od®• including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TILE BOND"m Roof Tile Adhesive LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 20-1214.01 and consists of pages 1 through 12. The submitted documentation was reviewed by Alex Tigera. NOA No.: 21-1006.03 Expiration Date: 08/23/26 Approval Date: 01/13/22 Pagel of 12 ROOFING COMPONENT APPROVAL Category: Roofing Sub Category: Roof Tile Adhesive Material: Polyurethane SCOPE: This approves TILE BON61 Roof Tile Adhesive and TILE BONDTM Roof Tile Adhesive (HFO) as manufactured by DuPont de Nemours, Inc. as described in this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable building code, do not exceed the design pressure values; as obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems and two piece barrel profiles using TILE BONVI Roof Tile Adhesives. 8660 PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Suecidiications TILE BONDTM Roof Tile N/A TAS 101 Adhesive TILE BONVm Roof Tile N/A TAS 101 Adhesive (BFO) PRODUCTS MANUFACTURED BY OTHERS: e 0 0 e o e e e o e o 0 0 0 0 0 00 o e o 0 e e o 0 Oeoe00 ea 00 oeooeo ProductMak intion e e e ooeoo;► 0aW0 o a 0 • e s a e o e e Single foam file oeoa eure component pol%e rgaf . e oee00 o eoo adhesive o e e a 00000 os eo 00 0 oe0000 Single component polruVhqne foam roof tile a 0 adhesive ° 0 06 a a e e i e e 0 0 0 a 40 0 00 0 0 0 0 0 oeooee Oe o 00 e o 0 0 0 e oe Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of TILE BONEP, Roof Tile Adhesive and TILE BON m Roof Tile Adhesive (HFO). MANUFACTURING LOCATION: 1. Wilmington, IL PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content TILE BONDTm Roof Tile Adhesive Test Results ASTM D 1622 1.6 lbs./fL3 ASTM D 1621 Parallel to rise 20 psi Perpendicular to rise 14 psi ASTM D 1623 31 lbf @ 180°F, 65% RH for 120 days, concrete to concrete ASTM D 2842 3% absorbed by Volume ASTM E 96 0 perms ASTM D 2126 -0.08% Volume Change @ 400C., 2 weeks -3.6% Volume Change @700C., 100% Humidity, 2 weeks ASTM D 2856 86% NOA No.: 21-1006.03 MlAMMl7AQE CCU1�1Y Expiration Date: 08/23/26 Approval Date: 01/13/22 Page 2 of 12 PHYSICAL PROPERTIES: (CONTINUED) TILE BONDTM Roof Tile Adhesive (UO) Pro a Test Results Density ASTM D 1622 2.2 Is./ft.3 Compressive Strength ASTM D 1621 23 psi parallel to rise 19 psi perpendicular to rise Tensile Strength ASTM D 1623 42 If ©,180°F, 65% RH for 120 days, concrete to concrete Water Absorption ASTM D 2842 1% absorbed by Volume Moisture Vapor Transmission ASTM E 96 3.1 perms Dimensional Stability ASTM D 2126 -0.01 % Volume Change @-40°C., 2 weeks 4.4 % Volume Change c@70°C.,100%. Hq timidity, Closed Cell Content ASTM D 6226 2 weeks 0 0 94% ° 00 ° P ° oeoo 000000 e e O ° 0 000000 0 0 o e ae oe og0000 poeea0 O O e Note: The physical properties listed above are presented gOeg00 as typical average valuWfid iieter cd 0 b accepted ASTM test methods and are subject to y P normal manufacturin�r v{°�Sg1y°.fyation ' ° ° 00006 boi� qe e 0 0 O 000 00000 0 0 0 EvimNCE SuBMrrTED: aye OO ° 0 g o e° P O O OO O OogOoe O o e Test AQencv Test IdentiSer q Test Name/Report o ° ate° e o ° q'' o e IBA Consultants Inc. 4848-8 ee m TAS 101 O 000 wl9/e8 e e a 4848-7 TAS 101 05/19/08 4848-6 TAS 101 05/19/08 4848-5 TAS 101 05/19/08 4848-4 TAS 101 05/19/08 4848-3 TAS 101 05/19/08 4848-2 TAS 101 05/19/08 4848-1 TAS 101 05/19/08 Trinity ERD D9840.09.09 TAS 110 09/ 17/09 MEMO etc. LLC 4L-DOW-18-002.12.19-A-Rl TAS 101 / TAS 123 08/28/20 4S-DOW-18-001.07.19-B-Rl TAS 110 07/31/19 NOA No,; 21-1006,93 ECOUN"M Expiration Date: 09/23/26 MW Approval Date: 01/13/22 Page 3 of 12 INSTALLATION: 1. TILE BOND Roof Tile Adhesives may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of TILE BONDTM Roof Tile Adhesives. 2. TILE BOND Roof Tile Adhesives shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of TILE BONDTM Roof Tile Adhesives shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof the assembly NOA. 3. TILE BONDTM Roof Tile Adhesives and its components shall be installed in accordance with Roofer Application Standard RAS 120, and DuPont de Nemours, Inc. TILE BONDTM Roof Tile A ftsive %Retdting ° ° ° 0: ° °° ° ° Instruction and Maintenance Booklet. O° ° ° ° 0 0 0 0 0 0 0 O O O O 0 0 0 0 0 0 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed -by wont de Nemours, O O O O O O O Inc. 0000 00 O 0 0 0 0 0 0 O 000 O O,O 0000 S. Pressure treated wood filler block or suitable piece of broken tile of similar size and sluap°e shall be requu ed on tie: 00000 eave course installation of flat, medium and high profile tile installed with the Interde=*pt adheaiiyg ° o 000000 placement. Two-piece barrel tile and all other tiles installed with the Independent plagowin do not require the .0 filler blocks. 00: 00 0 0 0 0 O: O 0 0 0 6. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after ME BOND" Roof o 00 ° oo 0 O 0 0: Tile Adhesives has been dispensed. ° ° ° 0 ° 0 00 7. TILE BONDTM Roof Tile Adhesive placement and minimum patty weight or minimum contact area shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Placement may be modified as needed for the particular file configuration as long as the minimum contact area is achieved. LE IITATIONS: 1. Fire classification is not part of this acceptance. 2. TILE BONDTM Roof Tile Adhesives can be used with cap and pan, ridge, flat, low, medium and high file profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of TILE BOND Roof Tile Adhesives with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. �F1 _ 1 W F MS 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 21-1006.03 �artFOAna couwrY Expiration Date: 08/23/26 Approval Date: 01/13/22 Page 4 of 12 LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. O O O O O O O O 0000 BUILDING PERMIT REQUIREMENTS: ° ° o 000000 ° ° O O O ° ° O O o As required by the Building Official or applicable building code in order to properly evaluate the $ds�taallatioS bftbis ° ° ° ° ° ° system. ° °°e°oo ° e O ° O O ° ° O O O O O O O O O O O O O O 0 0 0 0 O 0 0 6 6 0 0 0 O O 6 0 0 6 0 0 O O O O 00000 O O O O O TABLE 1: ADHESIVE PLACEMENT FoR EACH GENERIC TILE.PROFILE O TILE BOND' Roof Tile Adhesive and TILE BOND' Roof Tile Adhesive 00) v ° ° 0. 0011 Tile Tile Placement Minimum patty Weight ° 00Minii�pm°Conta4° Profile Attachment Detail per the (grams) o Awd (Square inches Flat / Low Profile Independent #1 25 32 Flat / Low Profile Independent #2 12.5 16 Medium Profile Interdependent #3 25 32 Medium Profile Independent #4 12.5 16 High Profile (Head) #5 12.5 16 Hi Profile (Nose)Interdependent 12.5 16 High Profile Stacked beads Independent #6 25 15 Two Piece Barrel Interdependent #7 25 20 Trim Lock Metal Ridge Interdependent #1,2,3,4,5,6,7 25 13.5 Board or 2x Ridge Board NOA No.: 21-1006.03 Expiration Date: 09/23/26 Approval Date: 01/13/22 Page 5 of 12 DETAIL #2: LOW (FLAT) PROFILE - INDEPENDENT PADDY PLACEMENT Two parallel beads minimum 2" x 2" x 4" Placed apx.1"above head of previous row or apx.4"from eave Minimum 8 sq. in. contact area per bead Battens Optional NOA No.: 21-1006.03 Expiration Date: 08/23/26 Approval Date: 01/13/22 Page 7 of 12 DETAIL # 7 TWO PIECE BARREL TILE — INTERDEPENDENT PADDY PLACEMENT Two beads min. VX1"Xa"at side edges of pan tile to contact cap tile Mtn. i.s'X i.s"x a" bead under cerderlineof pan the Minimu n 1.5" continuous bead on ridge 1"X 1"X 4" END OF THIS ACCEPTANCE overlap NOA No.: 21-1006.03 Expiration Date: 08/23/26 Approval Date: 01/13/22 Page 12 of 12 MIAMZDADE M MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www•aaawdade ¢oy/economy Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 . . .... ...... SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of COOMS tction m3ferrals. Th0" • % documentation submitted has been reviewed and accepted by Miami -Dade County RER - PrpopiteCont el Sreetion to.'ba ..: used in Miami Dade County and other areas where allowed by the Authority Having Jurisdlgtjgti (AHJ), • , This NOA shall not be valid after the expiration date stated below. The Miami -Dade County; Yrgduct Cegtfef section * * * 6 (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reservethe right to havethis , product or material tested for quality assurance purposes. If this product or material fails topeNosm in the accepted .... % manner, the manufacturer will incur the expense of such testing and the AHJ may immedi4elyteyoke, inodiiy, or . suspend the use of such product or material within their jurisdiction. RER reserves the righf to revoke Jd% aegeptanee,' if it is determined by Miami -Dade County Product Control Section that this product or material fails to lnet tthe requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code, DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This new NOA consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigers. NOA No.: 18-0502.03 MIAMIOADECOUNTY Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 1 of 4 ROOFING COMPONENT APPROVAL Cate orv: Roofing Sub -Category: Underlayment Mat. SBS PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description 9660 BORAL TileSeal 36" x 36' rolls TAS 103 SBS self -adhering aspg��slet mato riat with a° ° ° "0" ° 36" x 72' rolls ASTM D1970 white glass re-enforce&jj*cster st jg fabece;° °; ° for use as an underlaywa&ia sloped roof ° ° °ee° o ° ° ° 6 ° ° 0° assemblies. 00600 : Boral Citadel Plus 36" x 72' rolls ASTM D1970 a 00*0 0 00 :0600 SBS self -adhering asp la9ater� a° evith poly film -facer; for useava mid-plyPandarlaymex� e ° 0 e in sloped roof assembliet: ° : 000 O O 00 0 000060 ° ° ° MANUFACTURIGN LOCATION: 0 0 e 00 e 0 ° ° ° ° ° ° " ° 0 0 O O O e 0 O O O O 1. Brentwood, NH. 0 00 2. Houston, TX. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials OCF-356-02-04 ASTM D1623 07/25/18 Technologies, LLC. OCF-356-02-02 TAS 103 07/24/18 OCF-356-02-01 ASTM D 1970 07/26/18 OCF-424-02-04 ASTM D 1623 07/25/18 OCF424-02-01 ASTM D 1970 07/25/18 OCF424-02-03 TAS 103 07/25/18 Trinity ERD APPROVED BRLRF-SC 16810.11.17 ASTM D 1876 11/28/ 17 NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: "/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D226 Type 11 or ASTM D2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. ...... Ply Sheet Apply one layer of Boral Citadel Plus over Base sheet as per current aQ�roval. .' .. .. (Optional): .. .. .. .:. Membrane: One or more plies of BORAL TileSeal Underlayment with a minimAsmT.' head lip W, ..... minimum 6" end lap. Place the first course of membrane parallel tothe eav e, rollingtke ..:..' membrane to obtain maximum contact. Remove the release membrane es the membraA is .... applied. Vertical strapping of the roof with BORAL TileSeal Undetrat bldnt is acceptable. All •, end laps and laps without black selvage area shall be sealed under lap using an 5BS n1gdifred' • "" .. mastic. ...... Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. NOA No.: 18-0502.03 MIAMI•DADE COUNTY Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 0 0 o 0 00 0 ° a 9o00°.° 5. BORAL TileSeal underlayment shall not be left exposed as a temporary .roof for longer Ikan 1S0 daysdof 0 0 0 0 0 0 application. 0*0000 00 00 0°oam0 ° 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when dies are loade8 directly. 0 0 0 O. to the BORAL TileSeal underlayment; loading boards or battens are required on roof pi4 *)e os�reaterUnn fx 12". 00000 ° 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed apprevabe this produsbwith 0 ° o e m ° specific prepared roofing products. 0° 00 a 0 00 0m 000000 0 8. Tiles shall be stored on battens on roof pitches greater than 6:12". : ° ° o 0 0 0 9. BORAL TileSeal underlayment may be used with an approved roof covering Notice ofAcc °tance" istt' 0 0 ° ° 0 Y Y Y PP g �P ��� 0 0 BORAL TileSeal underlayment as a component part of an assembly in the Notice of Accep&&e. IMORAL, ° TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AAJ) o;r,&e Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Refasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below a cou�rnr END OF THIS ACCEPTANCE NOA No.: 18-0502.03 �WadddMl�1M�Q�, � M7Y Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 4 of 4 Daises Local Business Tax Receipt Miami —Dade County, State of Florida -THIS IS NOT A BILL -DO NOT PAY 4975679 BUSINESS NAMMCADON DESIGN HOME REMODELING CORP 290 NW 161STST MIAMI FL 33169-6425 14i RRENEWAL EXPIRES 772416 SEPTEMBER 30,2 023 Must be displayed at place of business Pumumnt to County Code Chapter BA - Art. 9 & 10 OWNER SEC. TYPE OF BUSINESS DESIGN HOME REMODELING CORP 196 SPECIALTY BUILDING CONTRACTOR PAYMEBTRECENEO F ANTHONY GERACI, QUALIFIER CCCO67409 BYTAXCOLLECTOB Worker(s) t $75.00 08/07/2022 INT-22 383627 This Local Business Tax Receipt only confirms payment of the Local Business Tan. The Receipt is not license, permit Ora certification ofthe holdersqualificadons,te do business. Hold rmust comply with any govetnmemal or nmlgavemmemal regulatory laws and mquimmems which apply to the bosinoss. The RECEIPT N0. above most he displayed on all commercial vehicles -Miami-Dade Code Sec Sa-276. Far mom imormaUon,visitwww 'dada ovt+-xc to lector Ron DaSantis, Gavemof McWnlas. GrlRe4 Sevemry r ( � IOn(iP STATE OF FLORIDA a , r - DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION f vlvsI Kv6:I Ivr4'r,4V, 5-TRY,�LJCENStNG BOARD THE ROOFING CONT§A" TOR NER1 iN'IS_Cf T]FIEp UNDER THE _ •' it ` b'.Si. 47. ---DESIGNH.OME REMODELING GORP- 280N W 161ST51'REET. 'f,=... `l MEAMI :FL 33169 -LICEIVSEWUt E ERt C EXPIRATION DATE AUGUST 31, 2o24 Alwayswrify limns,, online at MyFIOrldeUc,ree.Com Do notafter this document in any fom. , This is your license It is unlawful for anyone other than the licensee to use this document. db CERTIFICATE OF LIABILITY INSURANCE 13ATE(MMIDDIYYYY) 09-19-2022 { THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER Marker Insurance, Inc. CONTACT Jonathan L SON- • (954)456-7505 C, (0j: 954 458-6520 1720 Harrison Street Ste 6-A Hollywood, FL 33020 aDaREs�!JonathanQT4rRerinsurance.com License #: L00450 INSURER($) AFFORDING COVERAGE NAIC # INSURER A: Kinsale Insurance Company 38920 -- _ INSURED INSURER s : Design Home Remodeling Corp 290 NW 161 St ST INSURER C :�- Miami, FL 33169-6425 INSURER D : INSURER E : Y_ INSURER F : %o=m I Iri%.iA i t IVUI1f1t3tK: UUUUZ 12a-0 REVISION NUMBER: 91 TI ff[1 In TA AI-11Tffwi �. f.w .... .� ��. •�.�� -� ...-.. r Ho io r v vr-r% r rr T 1 rite 1 1 rnC rr.rULIUI1. UI' !NbURANC E LISTED 5ELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, ' EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. I ;t R j TYPE OF INSURANCE - A L S(i13R1 POLICY & ' POLICY - POLICY NUMBER IYIMID i MMIDD LIMITS ¢� �X .COMMERCIAL GENERAL LIABILITY CLAIMS -MADE ❑X OCCUR 0100104280-2 01/01/2022 01101/2023 EACH OCCURRENCE_ $1.00,000 PREMISES (Ea oxurrenae) $ 1000000 MED EXP (Any one person) 1 S 51000 -- PERSONAL & ADV INJURY _ S 1 000 000 } GEN'L AGGREGATE LIMIT APPLIES PER: POLICY JET Loc 1 ' GENERAL AGGREGATE S 2,000,000 PRODUCTS - COMPIOP AGG $ 2,000,000 , $ OTHER: 9 AUTOMOBILE - LIABILITY ANY AUTO OWNED i— SCHEDULED AUTOS ONLY ;. - - AUTOS HIRED ' ' NON -OWNED AUTOS ONLY �__ _E AUTOS ONLY 1 COMBINED SINGLE LIMIT S BODILY INJURY (Per person) __�_�......__. $ BODILY INJURY (Per accident} S _. PROPERTY QAMAGE er accident S S - f{ UMBRELLA LIAR -+� OCCUR EACH OCCURRENCE ' S EXCESS LIAR CLAIMS -MADE AGGREGATE S '� ` DIED RETENTION WORICM COMPENSATION AND EMPLOYERS' LIABILITY Y I N ANY PROPRIETORIPARTNERIEXECUTNE OFFICERNEMBER EXCLUDED? ❑ (Mandatory In NH) If yes, describe under f DESCRIPTION OF OPERATIONS below NIA = { ! SER OR . b — E.L. EACH ACCIDENT _ S E.L. DISEASE -EA EMPLOYE $ E.L. DISEASE -POLICY LIMIT _ S DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If morn space Is required) Roofing Contractor #CCO57409, CBC057769 Building Contractor --- Village of Miami Shores Building Department 10050 NE 2 Ave Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE v 'IVco-zU7o ACORD CORPORATION. All rights reserved. ACORD 26 (2016/03) The ACORD name and logo are registered marks of ACORD Printed by JLO on 05/26/2022 at 09:25AM CERTIFICATE OF LIABILITY INSURANCE 12/14/2021 Producer: Plymouth Insurance Agency This Certificate is issued as a matter of Information only and confers no 2739 U.S. Highway 19 N. Holiday, FL 34691 rights upon the Certifiate Holder. This Certlficatie does not amend, extend or alter the coverage afforded by the policies below, Insurers Affording Coverage NAIL # (727) 938-5562 .Insured: South East Personnel Leasing, Inc. & Subsidiaries Insurer A: Lion Insurance Company 11075 2739 U.S. Highway 19 N. Holiday, FL 34691 Insurer B: Insurer c: Insurer D: Insurer E: Coverages o policies of Insurance listed below have been issued to the imured named above for the Policy period Indicated. Notwlthstand ng any requirement, term or condition o any contract or othor document with respect to which this oertificate may be Issued or may pertain, the Insurance afforded by the policies described herein is subject to aU the terms, exclusions, and tmrtdidons of such policies. Aggregate limits shown may have been reduced by paid claims. INSR LTR ADDL INSRD Type of Insurance Policy Number Policy Effective Date Policy Expiration Date Limits (MM/DD/YY) (MM/DONY) ENERAL LIABILITY Commercial General Liability Claims Made ❑ Occur Each Occurrence Dam to ranted premises (EA Occurrence) Med Exp eneral aggregate limit applies per. Personal Adv Injury General Aggregate Policy a Project E3 LOC Products - Comp/Op An UTOMOBILE LIABILITY Combined Single Limit Any Auto (EA Accident) All Ovmed Autos Bodily Injury Scheduled Autos (Per Person) Bodily Injury fHired Autos Non -Owned Autos (Per Accident) Property Damage (Per Accident) EXCESSIUMBRELLA LIABILITY Each occurrence Claims Made Occur 1:3 Aggregate Deductible A Workers Compensation and Employers' Liability WC 71949 01/01/2022 01/01/2023 X WC state- to Limits oTH- ER E.L. Each Accident $1,000,000 Any proprietor/partner/executive officerimember excluded? RO If Yes, describe under special provisions below. E.L. Disease - Ea Employee $1,000.000 E L. Disease - Policy Umits $1,0m,000 Other Lion Insurance Company Is A.M. Best Com n rated A Exce!{ent . AMB # 12616 Descriptions of Operations/LocationsNehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 92-57-989 Coverage only applies to active employees) of South East Personnel Leasing, Inc. & Subsid'iaries that are leased to the following "Client Company": Design Home Remodeling Corp. dba Design Roofing Carp Coverage only applies to injuries Incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working In: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or email certificates@Itoninsuraneeoompany,com Project Nance; ISSUE 01-19-21 (PH). REISSUE 01 22 21 (KLT) in Date: B a 2020 CERTIfi1CATE HOLDER CANCEU.A'rtON MIAMI SHORES VILLAGE BUILDING DEPARTMENT Should any of the above described policies be cancelled before the expiratZon date thereof. the issuing Inaurer will andoavor to mall 30 day* written nouao to the oortificato holder named to the left. but failure to do so shall IRtpose no obligation or liability of any kind upon the insurer. Its agents or representatives. 10050 NE 2ND AVE MIAMI, FL 33138�r—