Loading...
RF-04-22-931Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 05/03/2022 Location Address Parcel Number 65 NE 105TH ST, Miami Shores, FL 33138 1121360060140 Contacts Permit NO.: RF-04-22-931 Permit Type: Roof Work Classification: Tile Permit Status; Approved Expiration: 11/03/2022 Jefferson W Geimer Owner ISAACS ROOFING & INSULATION Contractor 65 NE 105 ST, Miami Shores, FL 33138 CORPORATION ISAIAS DEL SOL Mobile: 3052345234 abigail@isaacsroofing.com Description: RE-ROOFTO CONCRETE S TILE Valuation: $ 20,800.00 Ins ection Requests: 305-762-4949 Total Sq Feet: 1,600.00 Fees Amount Application Fee - Other $50.o0 CCF $12.60 DBPR Fee $4.13 DCA Fee $2.75 Education Surcharge $4.20 Roofing Fee $225.00 Technology Fee $6.88 Total: $305.56 Building Department Copy Payments Date Paid Amt Paid Total Fees $305.56 Credit Card 05/03/2022 $255.56 Check N 16091 04/13/2022 $50.00 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT, Ice i that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regula'hg cons io a o ng. Futhermore, I authorize the above named contractor to do the work stated. �g 1& al?! a `J d oriz Signature: wner I Applicant / Contractor / Agent Date May 05, 2022 Page 2 of 2 RECEIVED Miami Shores Village Building Department BY:_ 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762.4949 FBC 20 BUILDING Master Permit No. PH-()H- 2-2-q.34i PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC Q ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL [-]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 65 NE 105 Street City: Miami Shores County Miami Dade Zip: -T7/JP Folio/Parcel#: 11-2136-006-0140 Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BIT: FFE: _ OWNER: Name (Fee Simple Titleholder): Jefferson Geimer Phone#: 786-999-3320 Address: 65 NE 105 Street City: Miami Shores State: FL Zip: 33138 Tenant/Lessee Name: Same Phone#: Email: 1W9eimer@yahoo.com CONTRACTOR: Company Name: 1 5GIOLC•S f-o0 ('1 nq Phone#:30r-2.3Q-S2-3 cf Address: 17 22- S S D f X2 FitAl & -e- 2- City: RCA I yv- Pcly E" 1961 State: FItr Zip: 33 1 ,5 �4- Qualifier Name: SSA t ct S rt> G ( Col Phone#:317 S- '11?8- 8803 State Certification or Registration #: GCL, 13 Z-7g"O I Certificate of Competency #: DESIGNER: Architect/Engineer: State: Zip: Value of Work for this Permit: $ 20 1�0 V ' n o Square/Linear Footage of Work: i (�OC'-7 Type of Work: ❑ Addition ❑ Alteration ❑ New ❑■ Repair/Replace ❑ Demolition Description of Work: R e.- aoQ r- -1­9 Coy.( r1ff'4-e' S T t D Specify color of color thru tile: 11 Ov n q ,, v\V/ kj e. q Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CCF $ - _ CO/CC $ DBPR $ Notary Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing Information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise In good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. I , Signat / 1- OWNER or AGENT The foregoing instrument was acknowledged before me this 17 111� day of ikP 2l (_ , 20 .7)Z by J�C/`FEFU'OA) 6—Ei n.l E/L , who is personally known to me or who has produced identification and who did take an oath, The foregoing instrumeyt was acknowledged before me this 13 IL- day of iq P2( L 20 ZZ by n A I A R D EC S' UL who is personally known to as me or who has produced identification and who did take an oath. as NOTARY PUBLIC: NOTARY PUBLIC: �,,\ Sign: 1L` Sign: Print: MARIH ELENA CRISTOBAL Print: MARIH ELENA CRISTOBAL Seal: Seal: " MARIAELENACRISTOBAL MARIHELENACRISTOBAL `- ,: MYCOMMISSION#GG 987418 MY COMMISSION 987418 imi : , ro; EXPIRES: May 12, 2024 ''' EXPIRES: May 12, 2024 ++«+«+«« % APPROVED BY S ( Plans Examiner Zoning Structural Review _ Clerk (Revised02/24/2014) Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.4ov SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics -Workmanship: the workmanship provisions of Section R4402 are f e purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the a reement between the owner and the contractor. Renailing wood decks: When replacing roofing, the existing wood roof deck ay have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation ke!y4en neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of ad' ent units of roofing to be performed. 4. _ Exposed Ceiling: Exposed, open beam ceilings are where the underside of the o decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be ac table. This provides the option of maintaining the appearance. S. Ponding water: The current roof system and/or deck of the building may not krAi:p/well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. Rev01 142021 Owners roofing consideration Page 1 of 2 Lit Miami Shores Village - BUILDING DEPARTMENT t� 10050 NE 2 Ave Miami Shores, FL 33138 i� «< 305-795-2204 www.msvfl.aov all ES IN 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that trtheo f is not overloaded from a buildup of water. Perimeter/edge wall or other roof sion may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Se ions R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural :�tt through the interior of the structure assembly (the building itself). The existing of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. _-� Z o 2Z — - ---- Z Ow r/Age 's Signature Date Co tract r igna re Date For Forms and Applications click here: http://bldg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia miShoresVillage Rev01 142021 Owners, roofing consideration Page 2 of 2 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.gov OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2"d Ave Miami Shores, FI 33138 Re: Owner's Name: SeWerSon lmcr Property Address: (OS- N G— f DSO si- Roofing Permit Number: Dear Building Official: I JTEFnJ ErCM s,2 certify that I am not required to retrofit the roof cThall connections of my building because: e just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) �Signai►� e - State of Florida, Miami Dade County Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this I' i day of Notary Public, State of Florida at Large MARIA ELENA CRISTOBAL MY COMMISSION R GG 987418 FYPIRFR-li 1 2024 M,ARIA ELENA CRISTOBA%-,44-g, V Bonded 7Tm Notary Public UndelwAlen • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. For Forms and Applications click here: http://bldg.miamishoresvillage-com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia miShoresVillage Pev01 1 4 V)) I Owner affidovit of exemption P�xae 1 0l Address Owner Name Folio SEARCH: 65 ne 105th st Back to Search Results PROPERTY INFORMATION Folio: 11-2136-006.0140 Su6•Divlslon: DUNNING$ MIAMI SHORES EXT NO 2 Property Address 65 NE 105 ST Owner JEFFERSON W GEIMER &W JENNIFER R Mailing Address 65 NE 105 ST MIAMI SHORES, FL 33136-2030 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SO Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY 1 UNIT Beds I Balhs / Halt 2 / 1 / 0 Floors 1 Living Units I Actual Area 2.344 Sq. Ft Suite I Tax Estimator Value Adjustment Board ASSESSMENT INFORMATION TRIM Notice Year 2021 2020 2019 Land Value $265,122 $230,638 $230.638 Building Value $133.772 $133,772 $133,772 Extra Feature Value $1,478 $1,484 $1,490 Market Value $400.372 $365.894 $365.900 Assessed Value $142.705 $140,735 $137.571 TAXABLE VALUE INFORMATION 2021 2020 2019 COUNTY Exemption Value $50.000 $50,000 $50,000 Taxable Value $92.705 $90,735 $87,571 SCHOOL BOARD Exemption Value $25.000 $25.000 $25,000 Taxable Value Sl17,705 $115.735 $112.571 CITY Exemption Value $50.000 $50,000 S50,000 Taxable Value $92.705 $90.735 $87.571 REGIONAL Exemption Value $50,000 $50.000 $50.000 Taxable Value $92,705 $90.735 $87,571 BENEFITS INFORMATION Benefit Type 2021 2020 2019 Save Our Homes Cap Assessment Reduction $257.667 $225.159 $228.329 Homestead Exemption $25.000 $25.000 525,000 Second Homestead Exemption $25,000 $25.000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i a County, School Board. City, Regional). a R�ECF,IVED ROOF ASSEMBLIES AND ROOFTOP STRUCTURES by; Florida Building Code 7th0) High -Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) Master Permit No. Process No. Contractors Name/ /�S,C441 - Sly^ {1 hUt I)yJ, QI __ Job Address 65 /V E /OS 6 / I � //rr+L(/�'I A oQ" ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF TYPE /' ❑ New roof ❑ Repair ❑ Maintenance b Reroofing ❑ RecoverlDi"•, ROOF SYSTEM INFORMA ION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF)� .....7otal ($F_40 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. IRclude-dimen .. sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of padped. '..*.: ...... : . .. . ...... CITY "'COPY Miami Shores Village Bu ding Departme Zoning Dept. Date Building Dept. Date Subject to compliance It all Feder I State and County rules and regulatiRE&RIDA BUILDIN Permit# G CODE — BUILDING, 7th EDITION (2020) ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 7th Edition (2020) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: t, )row b D(A lILC111�� Notice of Acceptance Number: d I 04an. Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:4 Zone 2e: %4 Zone 2n:109 Zone 2r: j0F Zone 3e:L� Zone 3r jJ a Deck Type: PlywoocQ 15161t Roof Slope:Type Underlayment: STM 'Na 6 T r I 3 12 •••• Insulation: /^//iL ...... Fire Barrier: Ridge Ventilation? Fastener Type&Spacing: 14 6k I— i/yl�•�fl`OUC+��S .' 1J i — 5 Adhesive T R•n�s Fos}ntd fl,I•'t7G tAfh ��" �rpfL(•,:• .. Type: sQIF adhPAe • •' : ..0. ....:. Type Cap Sheet: I'6Iy�jlas;•• I l/� ��•;1;r ;••••� Mean Roof Height: Roof Covering: G re \ 1 (Afyff� PHZR(e T pe &Sizes Drip �x3t 6A /AtlV' j1 F n. I, (�% 476 FLORIDA BUILDING CODE — BUILDING, 7th EDITION (2020) A ENTERED APR 2 5 2022 ROOF ASSEMBLIES AND ROOF -TOP STRUCTURES BY: r Florida Building Code 71h Edition (2020) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) 1 Roof System Manufacturer. —G1 r0w 1'1 R1,0t y) J Notice of Acceplance Number .d (— OL-�aL). 1� Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations) ( Zone 1 74 Zone 2e 74 Zone 2n ICV Zone 2, ]OF Zone 3e. ICS Zone 3r Vkk Roof Slope 3 12 Deck Type: P i�A:tJpp a 5/6 ( t Type Underlayment S Insulation: Fire Barrier: rl TM Ridge Ventilation? Fastener Type & Spacing: t 604" )- 1/411 kPf'nvlc(RS no � i-5/g 'Tin cep: F'i Oc R�Ni �'r`Stnfd ICI' OL tP(h .I^ eft Adhesive Type: Sp/F ad ltr!f� Type Cap Sheet: I uive IGS Mean Roof Height: ' Roof Covering: / rod V\ %N lb, C�/�.f(� Typem Drip C3 ��1 d` 67ACnfiIV Edge:: Si "�3`A L6 Got (�alv V,AI►cd eVlrY I Y� aPp,foved 2S IVa, l� �sTm M 70 Po Iva lcr-S rU Pam s spacTkS aFbacKna;1 : (t 476 FLORIDA BUILDING CODE — BUILDING, 7lh EDRION (2020) ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 7th Edition (2020) High -Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from M,. If the M, values are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (Zone 1:� x ), 054s = 2$- 16) - Mg: 2S= M„ 1q - I Product Approval M, 3e� 7 (Zone 2e:] x x OM3 =',1. i1) - Mg: &_%= M2a(!� Product Approval M, 1R. 7 (Zone 2nt& x x - Mgq" = Ml ,.e) . 4 Product Approval M, 'TAT, i (Zone 2r: a x xp 'Ai = 35.9 ) - Mg:" = M2r2_444 Product Approval M, q8. 7 (Zone 3e:� x x ¢ 3= 33 8 1- Mg:$ - = M .6 -L4 Product Approval M, '-W. -7 (Zone 3rYM x x per= W0.) - Mg: &--NR= M r!IA to Product Approval M, 'Sn - 7 Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval M, M, required Moment Resistance' Mean Roof Height Roof Slope 15' 20' 25' 30' • 40' 2:12 34.4 36.5 38.2 39.7 2.2 •• 3:12 32.2 34A 36.0 37.4 •• ••• 39.8 4:12 30.4 32.2 33.8 35.1 .37.3 .. 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 •32.4 7:12 24.4 25.9 27.1 28.2 • • • • •30.0 • 'Must be used in conjunction with a list of moment based the systems endorsed by the BroZard C lIunty Beard.Of Rules aW:. Appeals. For Uplift based tile systems use Method 3. Compare the values for P with the values for F,. If the F'walues�ary greater then or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. .. Method 3 "Uplift Based Tile Calculations Per RAS 127" (Zone 1:_ x L _ = _ x w: = _) - W: _ x cos r _ = F„ _ Product Approval F _ (Zone 2e:_ x L _ = _ x w: = - W: _ x cos r _ = F, _ Product Approval F' (Zone 2n:_ x L _ = _ x w: = _) - W: _ x cos r _ = FQ" _ Product Approval F' (Zone 2r:xL_=_xw:=_)-W:_x cos r_=Frr_ Product Approval F'. (Zone 3e:_ x L _ _ _ x w: _ _) - W: _ x cos r _ = FA• _ Product Approval F (Zone3r:_xL_=_xw:= )-W:_xcosr_=F,_ Product ApprovalP. Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analy- sis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 9 Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity M Product Approval Attachment Resistance M, Product Approval Required Moment Resistance M Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. FLORIDA BUILDING CODE - BUILDING, 7lh EDITION (2020) 477 4 � f I ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1626 HIGH -VELOCITY HURRICANE ZONES --UNIFORM PERMIT APPLICATION Florida Building Code 7th Edition (2020) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Attachments Required Permit Application Form See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive 13UR-RAS 150 A,B,C 4.5.6.7 Asphaltic Shingles A,B4O 1,2,4,5,6,7 Concrete or Clay Tile A,B.D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1.2.4.5.6.7 Other As Applicable 1.2,3,4.5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16. or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5 Municipal Permit Application 6 Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation FLORIDA BUILDING CODE — BUILDING. 7th EDITION (2020) 473 r 4 MIAMME M DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Crown Building Products of Florida, LLC. 6018 HWY. 72 Arcadia, FL. 34266 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www. m is m id ade.eov/econom v SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accgptednpanner, the manufacturer will incur the expense of such testing and the AHJ may immediately revokb, rgddify, or SDgpend the em: of such product or material within their jurisdiction. RER reserves the right to revoke As accellOtte, if it it. ..... .. ...... determined by Miami -Dade County Product Control Section that this product or material �� �: Tio meet the fequirements of the applicable building code. This product is approved as described herein, and has been designed to comply with'dV Florid2 Building Fblle•• including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Sanibel Concrete Roof Tile ' LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, stite aad following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 20-1105.09 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 21-0420.12 Expiration Date: 02/13/24 Approval Date: 09/02/21 Page 1 of 7 � t t ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This approves a system using Sanibel Concrete Roof Tile, as manufactured by Crown Building Products of Florida, LLC., and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Applicant Dimensions Specifications Sanibel Concrete Roof L = 17" TAS 112 Tile W = 13.25" H=3.1" Thickness: 0.56" Trim Pieces L = varies TAS 112 W = varies varying thickness 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BOND TM Roof Tile Adhesive Product Description Product e 0000O to ♦ 04006 000000 wipgon Dee eoeo e e High profile, interlock4dg7,0di1e-pieLV,'J3' shaped e e 0: e e concrete roof tile (Typeol`a Cass III), d'quipped.%4b. o two nail holes. For diPect cfmk or battened nail -on ®0O0 0 oao�o (4/12 min slope), mort� jj� pr adhe§ive %et e , e e O O applications. 000000 0O000a OOOOpQ Accessory trim, concret-eanaaf pieces for use at hips9 rakes, ridges and valley te*rm'natior.e 6 e 0 0 0 0 O Manufactured for each tile. profile. e e e o o e e e o 00 0 00 0 0 0 e o 0 0 00 Two component polyurethane foam adhesive. Single component polyurethane foam roof the adhesive. Touch `N Seal StormBonde One One component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive 2.2 MANUFACTURING LOCATION 2.2.1 Arcadia, FL Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. DuPont de Nemours, Inc. DAP Foam, Inc. NOA No.: 21-0420.12 Expiration Date: 02/13/24 Approval Date: 09/02/21 Page 2 of 7 2.� EVIDENCE SUBMITTED Test Agency Test Identifier PRI Construction Materials ACTI-002-02-01 ACTI-002-02-04 7161-03 Appendix III 7161-03 Appendix II P0402 Letter Dated Aug. 1, 1994 P0631-01 Redland Technologies Nutting Engineering The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Trinity/ERD American Test Lab of South Florida NEMO ETC, LLC PRI Construction Materials Technologies 13343.1 25-7688-3 25-7688-10 25-7688-5 25-7688-4 520111-3 520191-2-1 Calculations RT1028.01-13 RT1206.01-13 RT1203.01-18 4c-DPB S-20-L SOTM-O 1. A- Rl 2002T0003.08 Test Name/Report Date TAS-112 Sept. 2006 TAS-100 Sept. 2006 Static Uplift Testing Dec. 1991 TAS 102 & TAS 102(A) Wind Tunnel Testing Dec. 1991 TAS 108(Nail-On) Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Physical PropertieC .. ° ° :June 2006° ° ° ; ° 0 TAS 112 00 000000 0090° 0 0 0000 060000 0 Static Uplift Testing::: ° ° ° 11ne 19990 O 0 0 0 TAS 101 (Adhesive Set) ° ° ° o ° ° I&Y 1996,, 0, TAS 101 (Mortar Se4°0°° ° 00o609 Static Uplift Testing° a ° ° ° ne 19960 0 0 0 0 °1�o TAS 102 ®°°o°o �° (3"Headlap, Nails, Direct Deck, New °, 000000 O O Construction) O o a ® 00 0 O 000000 90 O Static Uplift Testing 00 O 0 o °14me 199; TAS 102 (4"Headlap, Nails, Clips) Static Uplift Testing Dec. 1998 TAS 101 March 1999 Aerodynamic Multiplier & Restoring Sept. 2006 Moment Due to Gravity TAS 112 11/13/13 Aerodynamic Multiplier & Restoring 02/05/14 Moment Due to Gravity TAS 112 12/11/18 TAS 101 12/17/20 TAS 101 10/06/20 NOA No.: 21-0420.12 Expiration Date: 02/13/24 Approval Date: 09/02/21 Page 3of7 3� LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 Mechanically attached tile minimum slope 4/12. 3.8 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION • • %• 4.1 Crown Building Products of Florida, LLC.'s Sanibel Concrete Roof Tile anA jts•components installed in strict compliance with Roofing Application Standard RAS 118, RAS114,'and 1 AS420 4.2 Data For Attachment Calculations • • •... shalC be.. Table 1: Average Weight (W) and Dimensions (I x w) : •'; Tile Profile Weight-W (Ibf) Length -I (ft.) "dth-vr (ft.) Sanibel Concrete Roof Tile 1 11.33 1.417 01• • .104 Table 2: Aerodynamic Multipliers - 2 ft' Tile Profile 2, (ft3) Batten Application 2. (ft3) Direct Deck Application Sanibel Concrete Roof Tile 0.289 0.313 Table 3: Restoring Moments due to Gravity - M9 (ft: Ibf) Tile 2":12 3":12" 4":12" VAT' 6":12" 7":12" or Profile greater Sanibel Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Concrete Roof Deck Deck Deck Deck Deck Deck 1 Tile N/A 9.05 N/A 8.96 8.79 8.81 8.60 8.62 8.38 8.40 8.13 8.16 NOA No.: 21-0420.12 Expiration Date: 02/13/24 Approval Date: 09/02/21 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf) for Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132" (min. 19132" plywood) plywood) Sanibel Concrete 2-10d Ring Shank Nails 28.6 41.2 19.4 Roof Tile 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screws 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail (Field 23.1 23.1 19.0 Clip) 1-10d Smooth or Screw Shank Nail (Save 29.3 29.3 24.0 Clip) 2-10d Smooth or Screw Shank Nails (Field 27.6 27.6 38.6 Clip) 2-10d Smooth or Screw Shank Nails (Save 38.1 38.1 , • • •, 41.8 Clip)•••• Table 5: Attachment Resistance Expressed as a Moment Mr•(ftsl(�f) for Two Patty Adhesive[ Set Systems •... ••.. Tile Tile Application KlAinum k eabhment.. Profile ••;Resi ce ..:. Sanibel Concrete Roof Tile TILE BONDTM Roof Tile Adhesive 19a •• •••• TILE BONDT Roof Tile Adhesive 583' ICP Adhesives Pol set9)AH-160 .34'. •••• Touch'N Seal StormBond® one component) 95 :.... 1 See manufacturer component approval for installation requirements. ; •„• 2 Medium paddy weight of 8 grams between tile and underlayment, paddy weight of 8 grams on overlap of tile of TILE BONDTM Roof Tile Adhesive 3 Medium paddy weight of 10 grams installed on the center of the back of the tile, second paddy weight of 20 grams on the underlayment. Place tile so that both paddys combine. 4 Medium paddy weight of 8 grams per paddy of Polyset® AH-160 5 Medium paddy weight of 8 grams between tile and underlayment, paddy weight of 4 grams on overlap of tile of Touch 'N Seal StormBond ® one component) Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Sanibel Concrete Roof Tile ICP Adhesives Pol set® AH-160 66.57 ICP Adhesives Polyset® AH-160 38.76 6 See manufactures component approval for installation requirements 7 Lar a add weight of 63 rams of Pol set® AH-160. 8 Medium add weight of 24 rams of Pol set®AH-160. NOA No.: 21-0420.12 Expiration Date: 02/13/24 Approval Date: 09/02/21 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment - Mf t.-lbf) ' for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Sanibel Concrete Roof Tile Mortar Set9 24.5 9 Tile-Tite Roof Tile Mortar. 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". a °°.. ° . °.... 000000 . ° ° ° 000000 ° °°.... ° .° ....° ..°... LABEL FOR SANIBEL CONCRETE ROOF TILE ...... o 0000 ° ° ` ° ° . ...°. (LOCATED UNDERNEATH OF TILE ° ° ° ° ° ° . ° ...°.. ° . . . .. O ....... . .. . . 000000 . 6. BUILDING PERMIT REQUIREMENTS: a o 00 ° ° ° ° ° o ° 6.1 Application for building permit shall be accompanied by copies of the follbwi;&- ° ° ° ° ° ° . 000000 6.1.1 This Notice of Acceptance. ° ° o ° ° ° ° ° 6.1.2 Any other documents required by Building Official or Applicable building°code in order to properly evaluate the installation of this system. NOA No.: 21-0420.12 Expiration Date: 02/13/24 Approval Date: 09/02/21 Page 6 of 7 PROFILE DRAWING 13 VV SANIBEL CONCRETE ROOF TILE END OF THIS ACCEPTANCE o e 0 0 0 0 0 0 0 0 e e o e 0 0 eeee o e ° eeee ° 0000we ° 0 0 ee0000 e° 000eoo ° o ° e 0 e 0 0 ° e e o 000ee e e o 00 00 o o o e o o o ° 0 eo ° ° 000000 0 0 e ° 00 0 0 000eoo ee 0 ° ° ° o 0 ° 00 NOA No.: 21-0420.12 Expiration Date: 02/13/24 Approval Date: 09/02/21 Page 7 of 7 MIAMFD MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w cn.miamidadawic/cconomV Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have ibis product or material tested for quality assurance purposes. If this product or material fails to perform7n tbtaccepteehmanner, the.... manufacturer will incur the expense of such testing and the AHJ may immediately revoke, mMify' or suspplldthe use of such product or material within their jurisdiction. RER reserves the right to revoke this aFggptance, if t iS .... determined by Miami -Dade County Product Control Section that this product or material fails,tp meet the requireme$te...: of the applicable building code. This product is approved as described herein, and has been designed to comply with the Fltmda 8uilding.Code ..:..' including the High Velocity Hurricane Zone of the Florida Building Code. • • • • • • .. ...... DESCRIPTION: Polyglass Polystick Underlayments ••••:. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,ocity,•state ;rid fSkowing� statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.17-0614.22 and consists of pages I through 7. The submitted documentation was reviewed by Jorge L. Acebo. MIAMMADE COUNTY ,... 1 NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 1 of 7 ROOFING COMPONENT APPROVAL Cateizory: Roofing Sub -Category: Underlayment Material: SBS, APP PRODUCTS DESCRIPTION: Product Polystick IR-Xe Manufacturing Location # 1 & #2 Polystick TU Max Manufacturing Location # 1 & #2 Polystick TU P Manufacturing Location #2 Polystick TU Plus (Surface Printing) Manufacturing Location # 1 & #2 Polystick MTS Manufacturing Location #2 Polystick MTS Plus Manufacturing Location #2 Test Product Dimensions Specification Description 65' x 3' Or 33.4' x ASTM D 1970 A fine granular/sand top surface self -adhering, APP 3' polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof 60 mils thick assemblies. Designed as an ice & rain shield. 65'8" x 3'3-3/8" TAS 103 and 60 mils thick ASTM D 1970 32' 10" x 3'3-3/8" TAS 103 and 130 mils thick ASTM D 1970 65' x 3'3-3/s" TAS 103 and 80 mils thick ASTM D 1970 A rubberized asphalt self -adhering, polyester reinforced waterproofing membrane. Designed as a air®®f tile ° ° ° ° underlayment. ° ° ° ° ° °°°°°° 00 r 0000 ° ° A rubberized asphalt waterprbe f memb , glass-....:. fiber/polyester reinforced, willl Ygi'anular surface designed for use as a the roof unaeslaym "Go A rubberized asphalt self-adtRedflg.oglass-ftbe°r/polyestsre ° ° ° reinforced waterproofing meMb?'a°ne. Desig4d as a me4a►1° ° ° roofing and roof tile underlaymen°t.9 ° ° ° °° ° ° ° ° ° ° 00 ° ° 60060 00 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt watgprggf ng ° 60 mils thick membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. 6518" x 3133/8" TAS 103 A homogeneous, rubberized asphalt waterproofing 60 mils thick membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Elastoflex S6 G 32' 10" x 3'3-%" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location #2 use in roof tile underlayment systems. MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 2 of 7 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Trinity ERD P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P37590.07.13-1 ASTM D6164 07/02/13 P45270.05.14 TAS 103, TAS 110 & ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103 & TAS 110 10/07/14 P43290.10.14 ASTM D 1970 & TAS 110 10/17/14 PLYG-SC 10130.06.16-3 TAS 103 & TAS 110 06/27/16 PLYG-10130.06.16-1 ASTM D1970 & TAS 110 06/27/16 PLYG-SC10130.09.16 ASTM D1623 09/22/16 PLYG-SC 13035.08.17 TAS 103 & ASTM D4798 10/32/17 LABELING: 00 o 1. All membranes or packaging shall bear the imprint or identifiable marking of the manutactuter's name BP logo, eitp ° O ° and state of manufacturing facility and the following statement: "Miami -Dade County. Co Aopproved" o Aoduct O or the Miami -Dade County Product Control Seal as shown below. nt°rbt ° 0 0 ° ° ° ° OOOOOp O ` ° ooy0 MMO IAMADE COUNTY ° O •poo :0boo° 6666o o ° V ,...� ` 00000 0 0 6 0 0 0 O O ° O ° O 0.000 O O O 00 go Go O° 060000 0 0 0 0 6 0 O o p O o ° ° O BUILDING PERMIT REQUIREMENTS: o ° O °O O a 0 a 0 : 0 ° Go ° 00 0 o000wp 0o Application for building permit shall be accompanied by copies of the following: O ° ° ° ° ° 06 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 21-0602.14 ,COUNTY Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 3 of 7 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated 0000 Deck Description: Min. 19/32" plywood or wood plank ° ° °A 0000 000000 " ® *owo ° • System Type E(2). Anchor sheet mechanical) fastened to deck membrane adhered*-*-*" * w * * y 0 0 w 0 ° Anchor/Base Sheet: 000000 One or more plies of ASTM D 226 Type II or ASTM D 2626. 0 0 0 0 °woe 0 ° ° ° $t2imuFastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a"m 4" Read lap. 406 °w owwsw* base sheet only) � ° ° ° * o u ° o ° w w ° ° Membrane: ew *° Elastoflex S6 G, hot asphalt applied w w w w w w ow wo ° 000000 w Surfacing: See General Limitations Below. o *° 0 * 0 0 w o ° ° * ° ° w 0 ° ° ° 00 0 ° 00 00 0 ° ° ° 0 00 O 0 000000 o ° Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 4 of 7 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flasting tape,';jjajlobe pressed in place and formed around the protrusion to ensure a tight fit. A second layer.QfPdlystick "Lbe applied over the underlayment. 000000 ° °: ° ° ° ° ° : ° ° ° ° ° ° ° ° ° ° ° °°°°°° GENERAL LIMITATIONS: ° 0000 ° : ° ° ° : ° ° °°°° ° °°°°° 1. Fire classification is not part of this acceptance. ° ° ° ° ° ° ° ° ° 0000 ° ° ° ° ° ° 2. Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic. sbywles, woo¢ s�iakes ° ° ° o and shingles, non-structural metal roofing, roof tile systems and quarry slate roof asseanbltes. 00 ° ° ° ° °: ° Polystick TU P maybe used in all the previous assemblies listed except metal roofing. .0. : ° 000 °° ° ° Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing andaroof tie °systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. ° 00 Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days) Polystick MTS Polystick IR-Xe Elastoflex S6 G Polystick TU Plus Polystick TU P Polystick TU Max Polystick MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 Hazelton, PA NIA 90 NIA 180 NIA 180 N/A::�j 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 5 of 7 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (E3) Profile MTS S6 G Polystick TU P TU Max MTS Plus MTS Plus with TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 .k.12 Tile without battens • • '.... ' 10. The above slope limitations can be exceeded only by using battens in accordance with.the..Approved 2,jle SystM.:: • Notice of Acceptance and applicable Florida Building Code requirements. When battens elra required,.they shall , be utilized during loading and installation of tiles. � • • • ..... Care should be taken during the loading procedure to keep foot traffic to a minimum aqd lQ avoid dti;'a dropping of • directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading4r"Mure ' ",%Oles lajd„• • perpendicular to slope followed by a maximum four tile stack parallel to the slope, foise•tolal of 6 tiles— for all .' underlayments except Polystick MTS which shall be loaded onto battens. • • .... % a a N N b Roof Deck prepared vi0h POLYSTICK TU Rua Roofing Tiles (6 Max. Per Sack) 12 6 I/ 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. NOA No.: 21-0602.14 rawrt►laaoecoutan Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 6 of 7 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 W metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick NITS. 00000 .e. 0 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Ii*r to the Po1ji f ass Tile ° ° o o ° Loading Guidelines. See General Limitations #9 and # 10. oe0000 6600 eoo 000006 e 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be u°sea on°all projects for o ° °.. o pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 'WYJY o,aprecautienr.Uould be ° taken, such as the use of battens to prevent the sliding during the loading process. ° ° e ° e o ° ° o ° ° e 0 0 oeeoo 7. Minimum cure time after membrane installation & before loading of roofing tiles is Wiy= Eight (4)°H®tirs. 000000 ° 8. Polystick membranes may not be used in any exposed application such as crickets, e4os�d dal ley�e or &xposec , . o 0 0 roof to wall details. ° o e ° , ° ° ° e e o o .00... 9. Repair of Polystick membranes is to be accomplished by applying Polyglass POLYPUS 50, XtraTlcx°SO ° Premium Modified Wet/Dry Cement or Polyglass PG 500 to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be fumished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 7 of 7 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.ctov SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES— REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics -Workmanship: the workmanship provisions cif S(Gtion R4402 are*--:- f Nie purpose of providing that the roof system meets the wind resLZ apse ant4 ,outer ..., instruction performance standards. Aesthetics (appearance) are not a consideration with....: respect to workmanship provisions. Aesthetic issues such as color or a citectt 'r"al" appearance, that are not part of a zoning code, should be addressed of the,: a reement between the owner and the contractor. : . .. . ...... Renailing wood decks: When replacing roofing, the existing-wood-roofdecZ' ay have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation bet en neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of ad' ent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the o decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be ac table. This provides the option of maintaining the appearance. 5. Ponding water: The current roof system and/or deck of the building may not rai well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. RevOI 142021 Owners roofing consideration Page 1 of 2 ,Es1� Miami Shores Village - BUILDING DEPARTMENT 19]1 V� 10050 NE 2 Ave Miami Shores, FL 33138 ii •, i8:69e* 305-795-2204 www.msvfl.ctov 6. overflow scuppers (wall outlets): It is required that rainwater flows off so that the ro f is not overloaded from a buildup of water. Perimeter/edge wall or other roof tfision may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Se ions R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airfl through the interior of the structure assembly (the building itself). The existing ount of attic ventilation shall not be reduced. It may be beneficial to considef.additional venting which can result in extending the service life of the roof. ^••^ .....^ 022 • 3 � � Ow r/Age 'ssignature Date Co tract r igna re••••• "'Date,,,,,• For Forms and Applications click here: http://bidg.m iamishoresvi llage.com/WebLink/Browse.aspx?id=118080&clBid=a&repo=Mia.:. mi5horesVillage •• ; Rev01 142021 Owners roofing consideration Page 2 of 2 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.gov OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: `f /131a- O_2-"Z 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Seizerson Es1f',imev Property Address: (0S N G— IOS 's-F Roofing Permit Number: ...... ... ...... Dear Building Official: 6-[-', M s-.2 certify that I am not required,to-retrofit.the rope ; tro all connections of my building because: °•..:. The just valuation for the structure for purpose of ad valorem taxationis, less than ,,,,,• $300,000.00. Please attach proof of ad valorem taxation. ""•' ❑ The building was constructed in compliance with the provisions of the rlorida BLrilding Code.:% (FBC) or with the provisions of 1994 edition of the South Florida Building Codr. (1994 5FBC) .....; e State of Florida, Miami Dade County TEF (::j A,) [ram /M jae__ Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this I Z)t- day of I9 P tz I 1 20 77 Notary Public, State of Florida at Large MARIA ELENACRISTOBAL MY COMMISSION # GG 987418 FXPIRrS- Mav 1212 2024 e •'••;;o'sv;9: Bonded Thru Notary Public Underwriters MARIH ELENIa C{.IOTCbr�� • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. For Forms and Applications click here: http://bldg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia miShoresVillage Rev01 142021 Owner affidavit of exemption Page 1 of 1 Property Search Application - Miami -Dade County Page 1 of 1 • •w OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-2136-006-0140 Property Address: 65 NE 105 ST Miami Shores, FL 33138-2030 Owner JEFFERSON W GEIMER 8W JENNIFER R Mailing Address 65 NE 105 ST MIAMI SHORES, FL 33138-2030 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SO Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds I Baths I Half 2/ 1 I 0 Floors 1 Living Units 1 Actual Area 2,344 Sq.Ft Living Area 1,837 Sq.Ft Adjusted Area 1,922 Sq.Ft Lot Size 9,225 Sq.Ft Year Built Multiple (See Building Info.) Assessment Information Year 2021 Land Value $265,122 2020q$3605,"'�900 $230,638 Building Value $133,772 $133,772 XF Value $1,478 $1,484 Market Value $400,372 $365,894 Assessed Value $142,705 $140,735 $137,571 Benefits Information Benefit Type 2021 2020 2019 Save Our Homes Assessment $257,667 $225,159 $228,329 Cap Reduction Homestead Exemption $25,000 $25,000 $25,000 Second Exemption $25,000 $25,000 $25,000 Homestead Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). I Short Legal Description MIAMI SHORES EXT NO 2 41-78 r 14 BLK 202 r SIZE 75.000 X 123 16933-3748 0995 1 Generated On: 4/13/2022 Taxable Value Information • :...:. ' •20�� 2020. ..201 County " ••••• Exemption Value $a1,Odb ; $$59,00Q %0,•00 Taxable Value 1 $$2,7 • $90,786 : 871574 .. School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value 1 $117,705 $115.735 $112,571 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $92,705 $90,7351 $87,571 Regional Exemption Value 0.0001 $50.0001 $50,000 Taxable Value 1 $92.705 $90,735 $87,571 Sales Information Previous Sale Price OR Book -Page Qualification Description 09/01/1995 $106,900 16933-3748 Sales which are qualified 05101/1990 $90.000 14539-3597 Sales which are qualified 06/01/1974 $58.000 00000-00000 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:/Aw .miamidade.gov/info/disclaimer.asp https://www.miamidade.gov/Apps/PA/propertysearch/ 4/13/2022 r NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. STATE OF FLORIDA: COUNTY OF MIAMI-DADE: TAX FOLIO NO. 11 eIM ao„)140 THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street / address: 65 NE 105 Strael . OUNNI NGS MWAI SHORES EXT NO 2 P8 41.78 LOT 14 6LX 202 LOT SIZE 75 000 X 123 OR IN33.314tt 0995 1 2. Description of improvement: gcca f Tr lt_ -*1!2 co M VV i-_G_ S 'Ti I -t - Owner(s) name and address Jelrerson Go mot 6 Jannder G- mar b r IV_F.r Q S •�n ?"t ,L� -� • tuI ► m S ho re s .f- Interest in property* gWj- y Name and address of fee simple titleholder: NIA tl Contractor's Warne and address - --- -- - - �----- ------ - - ----� �- - -� --- ---�-- 1S eLot-C- s I n 5y 1 0L4-1 w f► LP r p �72zs S .� � ��_� ±�Iw_ _ � - S+G •z.00 . ��lrn�c+�-o. F,� y , a �. �� i s �-_ _ 5 Surety: (Payment bond required by owner from contractor, if any) Name and Address. Amount of bond $ - - - - - — - - -- - -- - - - - -- - - --___ -- - - - - - 6. Lender's name and address WA 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and Address: lerreraon Gerner 65 NE tOS S1r0e1 61lanu Snores. FL 33136 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Signature of Owner Print Owner's Name_ ���0iCS i / Prepared by fto(Ad PS I J 0 j, 041LC loWift Sworn to and subscribed before me this it day off r', _I L , 20 ? Notary Public Print Notary's Name: My commission expires: c; MY COMMISSION 9 GG 98y418 A EXPIRES: May 12, 2024 �: Banded T ivu Notary Public UedesMtiters Address. dress. 17 Z7-C S b lhl C tt.A) L. s PCAJJ�Bi PL .'.-ItiHW�:;' Fl.tl!W'Ob � .- - ctYtt;PYCP4 i � ,.. : •.��,;, .;:�(j C;O?4 �. +,TRACTOR&, AND t'AA I f t�U,` SUPPLIERS W ct PROPER MADE PAYN-NT 1=. GI!i UNDER FLORIDA I-AW, YOUR FAILURE TO MAKE SURE TFIAT WE ARE PAID MAY RESULT IN A I;EN AGAiWl T..uf rc.TO AVOID A LIEN AND PAYING TWICE. YOU MUST (MTAFN r, WIPMT--t ISAACS ROOFING AND, at PHONE 305-234-5234 TO: CERT# 7101 0412 3440 2928 4125 JEFFERSON W 8 JENNIFER R GEIMER 65 NE 105TH ST MIAMI FL 33138-2030 WOI 2548567 DATE: 4/19/2022 BATCH: 49154 ID: ISA41 FILE COPY BY: JM T:JM R:PD S:PD The undersigned hereby informs you that he or She has furnished or is furnishing services or materials as follows: REROOF TILE TO CONCRETE S TILE 8 RELATED SERVICES For im rovement Of the real property described as: JEFF GEIMER 65 NE 105 ST, MIAMI SHORES LOT 14 BLK 202 WINNINGS MIAMI SHORES EXT NO 2 PB 41178 MIAMI DADE COUNTY FLORIDA (TR) WD 16933/3748 9/1/95 FOLIO 1121360060140 (long legal available 800432-1959) Under an Order given by: JEFF GEIMER ADS22033116T Fl),Ahv la+ (re.,i.nt•?c the serving ,.I ilI, III n_a 8 t r,sl,;, I yp.n it ,i .I t . - ;•:,yn: tl=. iu';,7r y nir ..nb.Ta it , Ns� vi nin 713.06 Florida Statutes. Pursuant to Flondi Statute 713 16, 1) please bunt. I, a -oh.y of you; du ect Conk act will) the conrtdcDJi He, i-, !it t _,i c,:{y, l-ilt, i5 Request. lo, Sworn ?Iaellient Of ApCOW il must be iddreiSed to ISAACS ROOFING AND, INSULATION CORPORATION. 17225 S DIXIE HWY STE 200. PALMETTO BAY FL 331574345 IMPORTANT INFORMATION FOR YOUR PROTECTION Indai Flondas law. Ihn who work en yoiit properly ui pmvtl m3lerinl- and ale not I airl have 0 nght el bne Iheirdanit )i payment ejaoSt your properly This claim Is known as i-onytu.Chon lien II p-w cunhacloi MIN to pay subrjnlw-A-.r y materiyl vt,pha,, .). neglects to make other legally tequ;red payments the people who ate owed money may look to your p,gpgrly for payment. EVEN IF VIA-) HAVE PAID YOUR CON FRACTOR IN FULL PROTECTYOURSELF -REi:oG,NIZE Ihat Ih)� Nobs II) Owner may re5vll in a lied :gams! yo;u pioperlt unle'>E all thnce supplying a to Uv.tier have npgn Paid --LEARN moi, about the Conslru•tion Lien Low.::h,tplai ,13 FEW L Flnela Statute;. and the nreaning Ih 01 n noure hp ror*ft'bn) an at wricy or the Florida Del,arbnent of 8lsmeS ar.-I Piotess Jnal Raqulatwn It a payment bond 8'n'Li(g LSi Ilbi project, this notice shall 30ive ae Ike- pre.hmmaiy ❑Ohre It intention to n,a lv,,. lain) ayaui;l aay 'Ah honrJl>) Regilesl tot it eopy of Die bond(s) is hereby elude. wal: ac Wnoivledgrnent of nsl "isiLJdy for ropy ,_r= rallute to hnniah the rsquemed ropy may ;on.Segnence; as described in Fh;IdJ Slatufes FIRM: INSULA TON SY: OWNER W NIFER CING ORPOAND RATION JEFFERSON 8 J N12 R125 17225 S DIXIE H W V STE 200 GEIMER PALMETTO BAY FL 33157.4345 65 NE 105TH ST �• MUUJI FL 33138-2030 Regina Durand, Agent ST COST OWNERI OF GEIMER MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 17-0322.03 and consists of pages I through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 1 of 11 Page 13 of 30 OF THIS PACKET ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof the adhesive Materials: Polyurethane SCOPE: This approves Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using Polysce AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications Polyset®AH-160 N/A TAS 101 Two component polyurethane foam adhesive ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPack® N/A Dispensing Equipment 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density @ 73°F ASTM D 1622 2.1 lbs./fi.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 14 PSI Perpendicular to rise Tensile Strength ASTM D 1623 29 PSI Parallel to rise Water Absorption ASTM D2842 7% Moisture Vapor Transmission ASTM E96 2.3 Perms Dimensional Stability ASTM D2126 +0.03% Volume Change @ -40° F., 2 weeks -1.1% Volume Change @158°F., 100% Humidity, 2 weeks Closed Cell Content ASTM D6226 94% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 2 of 11 Page 14 of 30 OF THIS PACKET 1EVIDENCE SUBMI'I'7'ED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1 PA TAS 101 12/ 16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21 /12 TAS 123 Cclotcx Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 NEMO ETC, LLC 4p-ICP-20-SSLAP-0 I. B- Physical Properties 12/4/20 Rl LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polyset® AH-160 shall solely be used with flat, low, & high the profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polyset' AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. S. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 3 or 11 Page 15 of 30 OF THIS PACKET INSTALLATION: 1. Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of Polyset AH-160. 2. Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polyset' AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. Polyset AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP Adhesives ProPack" 30 & 100 dispensing equipment only. 7. Polysetg AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within I to 2 minutes after Polysctr` A14-160 has been dispensed. 9. Polyset AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic the profile requires the specific placement noted herein. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 4of11 Page 16 of 30 OF THIS PACKET Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles # 1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 IIigh Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. HUV0�� BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMMaADE COUPIT1f NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 5 of 11 Page 17 of 30 OF THIS PACKET ADHESIVE PLACEMENT DETAIL # 1 Nall through plastic cement Paddy ghmeath Tile) (when required) f IOIn. s�\\ \ gym. Betc.nsoptional E.ve[oun. -% 10In. _s _ascia Feve <losun �� Nall through plastic cement (when required) fascia Closure Nall through plastic Iwhen requlradl _ - - Paddy (Beneath Tile) Underlayment x\ \ .-� I0In. \\. •\-� 2 In. wide Battens �. • \ optional j •`` \••: Eave Course -_ Fes C1. Weephole ,21n.� Ea.edosure IOIn. !/ Drip edge Flat/Low Profile Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 em2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile I. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x I" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set. 2. Continue in same manner. Insure approximately 17 (109.7 em2) — 23 (148.4 em2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile I. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/29/21 Page 6 of 11 Page 18 of 30 OF THIS PACKET ADHESIVE PLACEMENT DETAIL # 2 Nall through plastic cement paddy l8 cneath U.) twhen required) inddaayment ° It 7ln.ti. 21n. caneonnsoptlonal - Eaw Courw 10In. '• _ Fascia 'kiln Eaveelosure cement required) Battens Fascia Flat/Low Profile Tile Starting at the cave course, apply a minimum 2" (50.8 Trim) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm 2) - 23 (148.4 cm?) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the the being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12(77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x I" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) - 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the the closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm') square inch adhesive contact with the underside of the tile. (instructions continued on next page) NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 7 of 11 Page 19 of 30 OF THIS PACKET ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nall through plastic ce (when required) Paddy (Beneath Tile) IUnderlayment 7in. _ •'. `��♦ BattensoptlonOf a\\� Eava Course Fascia Weephole IBIn. 7 in. Eave closure Drip edge High Profile / Single Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the Overlock of the the being set. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set. 3. Continue in same manner. Insure approximately 17" (109.7 cmZ) - 19 (122.6 cmZ) square inch adhesive contact with the underside of the tile. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 8 of l I Page 20 of 30 OF THIS PACKET AD[ ESI VE PLACEMENT DETAIL # 3 Kul avough platccement Paddy becreemtBefl halter reeuhedl linens opterul. k • Paddy under the iStage f a or, op fi , attain. .�- Lnykpad toln In L; 0 1 } raffia f�.r--- FaRCbene Flavl-ow Profile Tile Kati through plastl<cmrcnt Shale paddy under the (Whm reeuhedl Paddirlael>reen tlnl Battens ' �� Paddy larder Mel optlenal ]■ab.w.��"• ingtepaddy on ` - 10 Fare Course Earl clown ` Focht Medium Profile Tile I. On the cave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x I" (25.4 mm) foam paddy onto the underlaymcnt positioned as shown, under the strengthening rib for flat the or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the cave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in' (109.7-148.4 em2) of adhesive contact with the underside of the the 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x I" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in (51.6-58.1 cm) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 9 of 11 Page 21 of 30 OF THIS PACKET ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Man through plastic Single paddy wWtr die 1when requIredl \ Paddy ltetween ties) BattensGPtWW paddy loader tikl an ' 4x4ln. t� �•. 2xaIn. -•� • t"op of tie — Em Course — `•i Fasda Weephole 101n. 2In. Eavve dosure Orlpedge High ProfileYlle APPROVED J 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3j4" (19 mm) paddy on top of the cave course tile surface as shown, on top of the strengthening rib for flat the or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9(58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 20-1124.07 Expiration Date: OS/10/22 Approval Date: 01 /28/21 Page 10 of 11 Page 22 of 30 OF THIS PACKET ADHESIVE PLACEMENT DETAIL Two PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq.ln. Steep pitch applications In contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive In to 1 In. from outside edge of cover tile. Then Install the tEh. Ensure 20 to 2S sq.In. contact area. --. ° tlnderlayment - --�• Sheathing Eave closure (motor shown) Weephole Fascia Board Remove top portion of the cave course cover tile. Abut to second coarse of pan tiles. Ensure cave end of pan and cover tiles are Rush at cave tine. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tic wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 20-1124.07 Expiration Date: OS/10/22 Approval Date: 01/28/21 Page 11 of i 1 Page 23 of 30 OF THIS PACKET