RF-04-22-922Permit NO.: RF-04-22-922
Permit Type: Roof
Work Classification: Repair Roof
Permit Status: Applied
Issue Date: Expiration:10/08/2022
Location Address
Parcel Number
1235 NE 96TH ST, Miami Shores, FL33138
1132060143790
Contacts
ROBERT WILLIAMSON
Owner OBENOUR ROOFING SHEET METAL& Contractor
1235
SUPPLY CO. INC
JAMES OBENOUR
9822 NE 2 AVE SUITE 9, MIAMI SHORES, FL 33138
Business: 3057572612 OBENOURROOFING@AOL.COM
Description: TEAR OFF TWO ONE STORY FIRE GLASS SHINGLE
ns e
Valuation: $ 6,795.00 Iction Requests:
ROOFS. INSTALL OVER CORNING SUPREME AR THREE TAH
FIREGLASS SHINGLES
Total Sq Feet: 262.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$4.20
DBPR Fee
$3.75
DCA Fee
$2.50
Education Surcharge
$1.40
Roofing Fee
$200.00
Scanning Fee (Manual)
$9.00
Technology Fee
56.25
Total:
$277.10
Payments
Date Paid
Amt Paid
Total Fees
$277.10
Check# 11371
06/21/2022
$227.10
Check# 11288
04/11/2022
$50.00
Amount Due:
$0.00
Building Department Copy
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating construction and zoning. Futhermore, I authorize t" above npmed contractor to do the work stated.
Authorized Signature: Owner
/ Applicant /
Agent
Date
June 21, 2022 Page 2 of 2
Miami Shores Village
�c'ti:IVED
BuildingDepartmentAvenue,
Florida R
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
BUILDING
PERMIT APPLICATION
❑BUILDING ❑ ELECTRIC 19400FING
FBC /21[0J,
Master Permit No. .0 I - 2Z IQ
Sub Permit
❑ REVISION Ej EXTENSION ❑RENEWAL
F-IPLUMBING MECHANICAL DPUBLICWORKS 0 CHANGE OF CANCELLATION 0 SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: /234,— A%:E 96
City' Miami Shores County Miami Dade Zip: 3 3/ 3 '-
Folio/Parcel#: —o/ V —31 /1' Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): '/2' j%n" Phone#: c' el v 7J
Address: /'7 3 j Nr Y / .f /
City:
Tenant/Lessee Name:
Email:
State: ,` L
33/3 �--
CONTRACTOR: Company Name: 04f-✓0✓x Phone#: 3a'r7.r7. 1G /2�
Address:
City: X%i s?Nt� S%v iC1
31/3Y.
Qualifier Name: h,,-Pis /D /74Y.✓y✓/4- Phone#: 364— 'Zr7-JG/L
State Certification or Registration M. LG L O/ �/ 3 o C Certificate of Competency #:
DESIGNER: Architect/Engineer:
Address: / City: State:Zip:
Value of Work for this Permit: $ G 7�J,t . Square/Linear Footage of Work: Z/r Z
Type of Work: ❑ Addition ❑ Alteration ❑ New E Repair/Replace ❑ Demolition
Description of Work: lCo2 r<F 2
/J,al,.� �. e..:.. l• SlA/J f..i // /L 3 A Z t4'4ZSs S 4 /w 5
Specify color of color thru tile: ✓/r1�\ r\
Submittal Fee $ _ Permit Fee $ ' U V CCF $ 4ZV CO/cc $
Scanning Fee $ I • U�}I/ Radon Fee $ .�� D//B''PR $� Notary:
Technology Fee $ I - CT� Training/Education Fee $ I •'T O Double Fee $,
Structural Reviews $ �-.eev!� Bond $
TOTAL FEE NOW DUE $
(Revised02/24/2014)
Bonding Company's Name (If applicable)
Bonding Company's Address
City 51
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
E.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection whlo occurs seven (7) days after the building permit is issued. in the absence of such posted notice, the
inspection will not be a d apl reinsRectioylfee will be charges
The foregoing �instruum'e/qi:: was
� � dayof1/✓
7
-/ L ,l1'44�
me or who has produced
20 -,q7' , by
who is pummally known to
identification and who did take an oath.
NOTARY PUBLIC:
Seal:
APPROVED BY
CATHERINE A. DUFFIN
MY COMMISSION 9 HH 089522
EXPIRES; May 14, 2026
as
The foregoing instru t�w�as ajknowledged before me this
J//L L day of :� ^� 20 �Z/ by
, AM ey [I b egoc-✓ , who is erson own to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
4. 7—
Plans Examiner
Cg7HERINEA�-1N
&'YCOMMISSION # HH 089522
ES;
:;ded ES:
EXPXPIRMay 14, 2025
_
(Revised02/24/2014)
Structural Review
Clerk
A N A R E N: l I E R 1 N D 1 6 R
0 99
May 31, 2022
OBENOUR ROOFING, SHEET METAL & SUPPLY CO.
c/o Jim Obenour, Jr
9822 NE 2ND AVE NO 9
Miami Shores, FL 33138
Via email: obenourroofing@aol.com
RE:1235 NE 96 St
Miami. Shores, FL
Hello Mr. Obenour:
As per the inspection conducted today at 1235 NE 96 St of the two shingle
overhangs on the rear of the property, these are my findings:
Based on Section 707.3.2 7h Edition (2022) FBCEB, the existing overhang diagram
located on the HVHZ does not meet the current code requirements. This is
because the roof diaphragms connection to the roof framing members and roof -to -
wall connection are not adequate to resist 75% of the current wind uplift under
current conditions.
Any questions., please feel free to call me
Bernardo Coiffman, PE 56562
May 31, 2022
Digitally signed by
Bernardo L Coiffman
Date: 2022.05.31
13:18:27-04'00'
11 I 1 Kane Concourse #610* Bay Harbor, FL 33154 * 305-868-5717 * FAX 305-351-9835 CA 31174
RECEIVED
i 'OOF AS--EMBLIES AND ROOFTOP STRUCTURES - CITY
( Florida Buie IngZone
a Uniform
or Permiditiont
( ppli)O PY
High -Velocity Hurricane Zone Uniform Permit Application Folic
Section A (General Information)
Master Permit No. Process No.
Contractor's Name D/jENOu�C %Zopt'��Il
Job Address �� 3S NF .S-
ROOF CATEGORY
❑/ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
L Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF TYPE .....
❑ New roof ❑ Repair ❑ Maintenance Reroofing •1�,•Recoveririq*
ROOF SYSTEM INFORMATION ...... ..:. ....:.
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) ..... Total (SF)-!,!
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and ovVI op Grains. Inclyde dimen-
sions of sections and levels, cleady identify dimensions of elevaterj pressure zones and location of parapets
Ally •• ;•. •.
k
Miami Shores Village uilding Department
Zoning Dept. Dat
Building Dept. Da
Subject to compliance wI all Fed tare
and County rules and regulations.
hermit*A. i
FLORIDA BUILDING CODE— BUILDING, 7th EDITION (2020)
0000
0 0
000000
0000
O 0
0
e O 9-
0
0000
0 00 -
0
0
000000
0000
000000
O
O 0
- 0
000000
000000
_
0 0
0 0
0000
000000
0 O
00000
0
0000
0 0
00000
0 O
000000
000000
O O-
0000e0
O
00 00
0
e
OeeeOe
000000
0 00
0 O
0 0 0
0 0
00 O
O 0
000000
0 O 0
O O
0 00
O 00
0 O 0
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code7th Edition (2020)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer: _
Notice of Acceptance Number:
,✓
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1:_ Zone 2e: Zone 2n:Zone 2r Zone 3e:_ Zone 3r:_
`V Deck Type: a>s�
\ TypeUnderlayment:; ,4:ffry, D��C
�c •^••
Roof Slope:12
......
Insulation:)
y/
Fire Barrier: �/�
••••••
.... .
.....
...... .
.....
Ridge Vent'lation?
Fastener Type &Spacing:
...�.
Adhesive Type: DyELF 4-,0 �� •.
�....4
jW;J0 ..
Type Cap Sheet:
�j/y9/A�s 1ey 9P1/vt lr ✓.l�i�e�/ryi,rPwT
r �
Mean Roof Height:
/'° Roof Covering:
\ Type & Size Drip
9�' 9Al✓�
���
IN Edge:
v7G
476 FLORIDA BUILDING CODE —BUILDING, 7th EDITION (2020)
I v
♦
• ••••
••••
• ••
••••
••
•
••••
••••••
•••
•
M I A M MD=AMM*
MIAMI-DARE COUNTY
ME
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2574
99
T (78� 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eoy/economy
Owens Corning Roofing and Asphalt, LLC
1 Owens Corning Parkway
Toledo, OH 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to hay ethic
product or material tested for quality assurance purposes. If this product or material fails to perfraft in thelemepted •
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately.rey oke, modify,'or • .
suspend the use of such product or material within their jurisdiction. RER reserves the right U).Wpke this aiceptanc
if it is determined by Miami -Dade County Product Control Section that this product or material fails to rueet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Flofi*130ilding bode • • :
including the High Velocity Hurricane Zone of the Florida Building Code.
.. .. . ......
DESCRIPTION: Supreme AR 3 Tab Shingles .. • : ; �'
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state aidUllbwing
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or changc in tho
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA#12-1204.03 and consists of pages 1 through 4.
The submitted documentation was reviewed by Freddy Semino a
NOA No.:18-0215.01
MIAMMADE COUNTY Expiration Date: 03/20/23
.' . Approval Date: 03/15/18
Page 1 of 4
0 00 .
0 O 0
00 0 00 0
O O
000000
O O O
0 0 0 00
0 0
+• o 0 0
p O 00 0
000000
0 0 0
0
0
000090 0
p0 00 0
000000
0. ,•r
00000
00O0'O0
O O
0000 O
00000
O O O0O000
000000
000000 0000
000000
00 0 0000
O
0 -. 0000
000000
0 i.
ROOFING ASSEMBLY APPROVAL
Cater-ory_ Roofing
Si t� Asphalt Shingles
Materials 3-Tab
Deck T,v_ae ; Wood
SCOPE
This approves Owens Corning Supreme AR as manufactured by Owens Corning described in Section 2 of this Notice
of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Soecificatiions
Supreme AR 12" x 36" TAS 110 A heavy weight, fiberglass reinforced asphalt
oeoo
shingle o
MANUFACTURING LOCATION
1. Atlanta, GA.
2. Irving, TX.
3. Medina, OH.
EVIDENCE SUBMITTED
Test Agency
Underwriters Laboratories, Inc.
PRI Asphalt Technologies, Inc.
Test Identifier
R2453
OCF-415-02-01
OCF-417-02-01
OCF-419-02-01
OCF-415-02-02
OCF-417-02-02
OCF-419-02-02
• O e
0 0 0
00 0
ooe000
e
0 0. 0 0 e
0000
0 0
ooeo
oe0ooo
0 0
O 0 0 0
0. 0 0 0 0
0 0 0
0 0
Test NaMgftarte
e
Reference
ASTM D 3462
TAS 100
TAS 107/ASTM D3161
--oo 000.00
0
0 0 0 0 0
0 0
0 0 0 0 0 0 0 0 e 0
0 O O
O 0000
0 0 0 0
000000
0 90600
0 0
0 0 0 0. 0 O
000.eo
0 0 0 0 0 e 0
0
0 0
0
00 0 0 0 0. e o
0 0 O
0 e-6ate e
000000
00 0 O0 0 O
0
e 07/07/15
01/18/18
01/18/18
01/24/18
01/18/18
01/18/18
01/24/18
NOA No.:18-0215.01
Muwt�w�oE couKrir Expiration Date: 03/20/23
• Approval Date: 03/15/18
Page 2 of 4
LE%HTATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
5. Nailing shall be in compliance with Detail'B', attached.
LABEUNG o . ° O
° °
1. Shingles shall be labeled with the Miami Dade Seal as seen below, or the wor4p "khami-MUM County ° ° ® o
0
Product Control Approved". o . 0 e o o 00610 °
.
°.°000
ooeeoo ° ° °
MlAMl�DADE COUNTY ° ° • ° o o ° ° ° °
° • °.°eoo
• • • • f 0000 . 00000
o 0
0000.0 .00° oe.
0 0 oosoeo
BiTII wNG PERMIT REQUIREMENTS o o o 0 o o .
000000
°
o °
1. Application for building permit shall be accompanied by copies of the following: ° ° e .
0 0 0
o eo
. 0
1.1 This Notice of Acceptance. o o e ° . e°°°
1.2 Any other documents required by the Building Official or the applicable code°in ord0g teoproper y .
° 00
evaluate the installation of this system.
NOA No.:18-0215.01
MraMMoaoacoun�ry Expiration Date: 03/20/23
Approval Date: 03/15/1
Page 3 of 4
J', ,�..
ov00
0 0
000000
�u.00
0 0
0
-
_ • 0 ., ,4 •
p
0000
_
O 00
000000
61600
000000
O 1
0 0
0
000600
000000
0000 -
000000
0 O
00000
0
v000'-
O O
00000
O O
000000
000000
0 0
000000
0
00 00
0
000000
O
0 0 0
000000
0 00
0 0
0 0
0 0 0
00 0
0 0
000000
0,
0 90.
O 0 O
0 OV
p
oov0: o
ry
`.
EXPOSURE
DETAIL A
DETAIL B
NAILS
511
8
0000
0 0
0 0
aeon
00,0000
0 00 0 0
o
OooO
0
p
000000
0
00:0
o00e0o o
000000
0
a 0
ooao
0 o
9 0 0 0 0 0
O b
OOOoo{�
e e
0000
O
00000
600000
r 0
a O
09000
O 0
O 00000
0 0 0 0
O
000000
OOOOOa
® O O
O
O O
O O
O
a00Y00
o a
0 O 0
0 oe
o 0
0 0 0
0eooae
00 O
as a
0 O
0 0 0
0 00
ADHESIVE STRIPE
211—j 0 loll
END OF THIS ACCEPTANCE
1"
12"
NOA No.:18-0215.01
CIM41AMMMMMMOUb" Expiration Date: 03/20/23
Approval Date: 03/15/18
Page 4 of 4
O 00
PO a
O O O
oD a
0 °
0 0 0
OD000e
0 0
0 00
O 0
0 °
0 0 0
10 O
000400
O O O
0
O
090600
•O
00 00
O
000090
O O
O'A00D0
OPQO00
0
90000
O O
0000
O
00006
-- 0 p1
009000
- 0090
O P
0 O
000000
090900
0
0 0
°
POOPDp
0000
000909
4
0
90 0
0009
O
O 0 O
p p
O000
O
O00000
p 0
9600
.t �
UL Evaluation Report
UL ER2453-02
Issued: April 5, 2017
Visit Ws On -Line certifications Directory: www.ul.com/erdirectory
for current status of Report.
UL Category Code: ULEZ
CS] MasterFormat@
DIVISION:
07 00 00 —THERMAL AND MOISTURE
Sub -level 2:
07 30 00 — Steep Slope Roofing
Sub -level 3:
07 3100 — Shingles and Shakes
Sub -level 4:
07 31 13 — Asphalt Shingles
COMPANY:
OWENS CORNING
ONE OWENS CORNING PKY
TOLEDO, OH 43659
(419) 248-7060
hffP://www.owenscorning.com/
1. SUBJECT: Asphalt Shingles
CLASSIC®, SUPREME®, •, '
DURATION® PREMIUM, TRUDEFINITIONO DURATION®, TRUDEFINITIONO DURATION® STORM-
TRUDEFINITIONO DURATION® MAX-, TRUDEFINITIONO OAKRIDGE®, OAKRIDGEO,
WOODCREST®, WOODMOOR®, TRUDEFINITIONO WEATHERGUARD® HP, BERKSHIREOa,
DEVONSHIRE-,
WOODSTARTO STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI
BUILT STARTER STRIP
BERKSHIRE@ HIP & RIDGE SHINGLES, HIGH RIDGE HIP & RIDGE SHINGLES WITH SEALANT,
RIZERIDGE® HIP & RIDGE SHINGLES WITH SEALANT, WEATHERGUARD® HP HIP & RIDGE
SHINGLES, PROEDGE®, DURARIDGETM HIP & RIDGE SHINGLES AND PROEDGE® STORM® HIP
& RIDGE SHINGLES
2. SCOPE OF EVALUATION
■ 2015, 2012, 2009, and 2006 International Building Code ® (IBC)
■ 2015, 2012, 2009, and 2006 Intemational Residential Code ® (IRC)
■ ICC ES Acceptance Criteria for Quality Documentation (AC10). Dated December 2012
0 ICC ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012
0000
0 0
000000
0000
e •
p
0000
• ••
0
0
000000
0000
000000
•
• •
•
000000
••6600
• •
• •
0000
••0•00
0 e
00000
0
0000
0 0
00000
0 0
000000
000000
0 0
000000
0
00 00 •
0
0
p
e00000 ,
e
e 0 O
000000
O eo
0 e
0 0 0
0 0
00 0
e 0
000000
0 0 O .. .... ... - .-
0 0
0 00
0 00
0 0 0
•• • -
The products were evaluated for the following properties:
■ External Fire Exposure (ANSI/UL790, ASTM E108)
■ Wind Resistance (ASTM D3161; ASTM D7158)
■ Physical Properties ( ICC-ES AC438)
3. REFERENCED DOCUMENTS
■ ANSI/UL790 Eighth Edition, (ASTM E108), Standard Test Methods for Fire Tests of Roof Coverings
■ ASTM D3161-13, Standard Test Method for Wind -Resistance of Steep Slope Roofing Products
(Fan -Induced Method)
■ ASTM D7158-11, Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift
Resistance Method)
■ UL Subject 2375, Outline of Investigation for Hip and Ridge Shingles (UL Fire and Wind Tests)
■ ICC-ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012
4. USES
OWENS CORNING asphalt shingles described in this report are alternatives to asphalt shingles
complying with Section 1507.2.5 of the 2015, 2012, 2009 and 2006 IBC and Section R905.2.4 of the
2015, 2012, 2009, and 2006 IRC, and are Class A roof coverings for new and existing roofs. 0 0 0 °
° °
° 0 0 0 0 0
5. PRODUCT DESCRIPTION ° °
°° ° °°°°
°° 0 0 0°
°
°
°
ro°ernes
OWENS CORNING asphalt shingles are roof covering materials complying with the fe9QJ+jqg p p °
0
°°°°°°
° °
when installed as described in this report The products are three -tab shingles, lamina# ghingle% and,
0 ° ° ° ° o
hip & ridge shingles. The products are available in standard and metric sizes. ° 0000 ° o 00000
00000
Fire Classification: OWENS CORNING asphalt shingles covered under this Report�rAbeen tgstefor
°°
° ° ° ° °
fire classification Class A in accordance with UL790 (ASTM E108). Shingles tested imaggadance wqh
° ° ° 0 0 °
UL790 (ASTM El08) qualify for use under Section 1505.1 of the 2015, 2012, 2009 abd 20®6 IBCAnd 0
0 0 0 ° 0 0
Section R902.1 of the 2015, 2012, 2009 and 2006 IRC. 0 ° o ° ° ° °
0 0
° °
Wind Resistance: OWENS CORNING asphalt shingles covered under this Report have been fpstgq for
wind resistance in accordance with ASTM D3161 or ASTM D7158.
Shingles tested in accordance with ASTM D3161 are classified as Class F or Class A and qualify for use
under the exception to Section 1507.2.8.1 of the 2015 IBC, Section 1507.2.7.1 of the 2012, 2009 and
2006 IBC, or the exception to Section R905.2.4.1 of the 2015, 2012, 2009 and 2006 IRC.
Shingles tested in accordance with ASTM D7158 are classified as Class H and qualify for use in locations
as shown in Table 1504.1.1 of the 2015 IBC, Table 1507.2.7.1 of the 2012 and 2009 IBC or Table
R905.2.4.1 of the 2015, 2012 and 2009 IRC, where the maximum basic wind speed is 150 mph (67 m/s)
or less with exposure category of B or C (ASCE 7) and a maximum building height of 60 feet (18.3 m).
Installation must be in accordance with Section 1507.2.7 of the 2015, 2012, 2009 and 2006 IBC or
Section R905.2.6 of the 2015, 2012, 2009 and 2006 IRC, as applicable.
Physical Properties: OWENS CORNING asphalt shingles covered under this Report have been tested
for physical properties in accordance with AC 438. Shingles tested in accordance with AC438 qualify as
an alternative roof covering for use under Section 1507.2.5 of the 2015, 2012, 2009 and 2006 IBC or
Section R905.2.4 of the 2015, 2012, 2009 and 2006 IRC. When installed in new construction in
accordance with this report and the OWENS CORNING Installation instructions, the shingles are a Class
A fire classification roof covering. When the shingles are installed over existing roof coverings, the fire
classification is maintained.
Page 2 of 30
O 0
000000
0 0
000000
0
O
0
000000
00000
0 0
00000
0 0
000000
0 0
000000
0
0
0
000000
5.1 Three -Tab Shingles — Classic®, and Supreme®:
Classic® and Supreme® shingles are three -tab shingles manufactured with a single fiberglass
mat, coated on both sides with asphalt, and surfaced on the weather -exposed side with mineral
granules. The shingles are self-sealing and have a continuous bead of thermal -tab sealing
adhesive above the shingle butt on the weather side. The shingles are self-sealing and have a
dashed bead of thermal -tab sealing adhesive above the shingle butt on the weather side. See
Tables 2 and 3, respectively for product dimensions and manufacturing locations.
5.2 Five -Tab Shingles - Devonshirelrm
Devonshire"A shingles are five -tab shingles manufactured with a single fiberglass mat, coated on
both sides with asphalt, and surfaced on the weather -exposed side with mineral granules. The
shingles are self-sealing and have a dashed bead of thermal tab sealing adhesive above the
shingle butt on the weather side. See Table 13A for product dimensions and manufacturing
locations.
5.3 Laminated Shingles — Duration@ Premium, TruDefinition@ Durations, TruDefinition@
Duration@ Storm, TruDefinitionO Duration@ MAX, TruDefinitionS Oakridge@, OakridgeS,
WoodcrestO, Woodmoor@, TruDefinition@ WeatherGuardO HP, Berkshires:
Duration@ Premium, TruDefinitionS Duration®, TruDefinitlon@ Duration® Storm, TruDefinitionO
Duration® MAX, Oakridge@, Woodcrest@, Woodmoor@, TruDefinitionO WeatherGuard® kiP,"a a
Berkshire@ shingles are laminated shingles manufactured with 2 layers of fitbrgAs mat cbtled
with asphalt on both sides, and surfaced on the weather -exposed side with miriiral branules; """
0ato oa 0060
0
5.4 Hip & Ridge Shingles — Berkshire@ Hip & Ridge Shingles, High Ridge HIVWRidge with,*
Sealant, ProEdge@, ProEdge@ Storm®, WeatherGuardS HP, Duralkidge? RIA and Mol*"
Shingles, and RIZERIdgeS Hip and Ridge shingles with Sealant: a a"a
a00000 a a o
O a 0 0 0 0 0
Berkshire® Hip & Ridge Shingles, High Ridge Hip and Ridge Shingles with SMIM, ProEtlge@,
ProEdge StormT", WeatherGuard® HP, DuraRidgeTm Hip and Ridge Shingled"irfd RIZERidgb@
Hip and Ridge shingles with Sealant are prefabricated hip and ridge shingles! ProF-dge 3fornf';"
and WeatherGuard@ HP hip and ridge shingles are perforated so they can b® torsi into three 12
inch by 12 inch (305 mm by 305 mm) shingles. ProEdge@ hip and ridge shingles and o a 0 a
RIZERidge@ Hip and Ridge shingles with Sealant are perforated so they can be torn into three 12
inch by 12 inch (305 mm by 305 mm) shingles for standard , or four 13 % inch by 9 27/82 inch (337
mm by 250 mm) shingles for metric.
5.5 Starter Shingles - Starter Strip, Starter Strip Plus, Woodstart Starter Shingle, and Tri-Bullt
Starter Strip
Starter Strip, Starter Strip Plus, Woodstart Starter Shingle, and Tri-Built Starter Strip are
prefabricated starter course shingles with factory applied sealant. Starter Strip and Tri-Built
Starter Strip are 6-5/8" x 39-3/80. Starter Strip Plus and Tri-Bunt Starter Strip are 7-3/4" x 13-3/8".
Woodstart Starter Shingles are 13-3/8" x 40".
6. INSTALLATION
OWENS CORNING asphalt shingles must be installed in accordance with the applicable code, this report,
and the manufacturer's published installation instructions. The shingles must be installed in accordance
with Section 1507.2 of the 2015, 2012, 2009 and 2006 IBC or Section R905.2 of the 2015, 2012, 2009
and 2006 IRC, as applicable, except as noted in this report.
The manufacturer's published installation instructions must be available at all times on the jobsite during
installation.
Page 3 of 30
00a0a0
"
0
0
O O O 0 0 O
e o
0 0 0 0 0 0
0 0
00000
0 0
0 0 0 0 0
oa00 0
0
0
m
"aoo0a
0 0
0 0 0 0 0 9
O O
.? Y
oeaoeo
s•ed.e
- - s •
0
0ea6
0 en r
OOOb00
OOOb
600000
a
o a
e
s•s•ee
.
o000aQ
r
OOOOQ
Q
0006
00000
0 a
000006
0000bo
0 0
0
6
saeeo.e
e e e
0aaa6a
• ..fie
o _ o
0 0
0 0
0 oe
o se
00 0
6.3.1 Three -Tab Shingles — Classic®, and Supreme®:
For roof slopes of 2:12 up to 21:12 (16.67% or 90 up to 175% or 60"), each shingle must be
fastened to the roof deck using a minimum of four fasteners, spaced as shown in Tables 2
and 3.
For roof slopes over 21:12 (175% or 600), six fasteners must be used, spaced as shown in
Tables and four 1 inch diameter spots of asphalt plastic cement per shingle (2 inches up from
the bottom edge), spaced as shown in Tables 2 and 3.
Fasteners must be located above the top of the cut-out and below the sealant strip, % inch
(16 mm) above the tab cut-out
Maximum exposure to the weather must be 5 inches or 5-% t'/8 inch (127 or 143 t 3 mm). In
colder climates or wind regions where it is questionable whether the thermal -sealing adhesive
will activate to seal the shingles, the shingles can be hand -sealed. A 1-in diameter (25.4 mm)
spot of asphalt cement complying with ASTM D4586, Type I, Class I, should be placed under
the corner (1 — 2 inches (25 — 51 mm) from each end) of each tab (two spots per tab).
6.3.2 Five -Tab Shingles — Devonshire'":
For roof slopes of 2:12 up to 21:12 (16.67% or 90 up to 175% or 600) each shingle muSf6e °
fastened to the roof deck using a minimum of six fasteners, spaced as s6owla Table°f3A. ° ° ° ° o °
°° ° °°°° °
° °
For roof slopes over 21:12 (175% or 600), six fasteners must be used, aild tGM I inch° ° ° ° ° ° ° ° ° °
diameter spots of asphalt plastic cement per shingle and two spots of asDhaft°Mastic cement o ° ° ° ° e
under each shingle tab spaced as shown in Table 13A. O 0000 ° o ° ° ° e ° ° °
°°°° ° °°°°°
° °
Fasteners must be located 6-1/8 inches (157 mm) above the butt edge o°�nglese ° ° ° o ° ° ° ° ° °
00 00 ° ° ° ° ° ° °
o
Maximum exposure to the weather must be 5-5/e t'/8 inch (143 t 3 mm): ° ° a ° o ° °
° ° ° ° ° ° ° ° ° ° °
° ° °
In colder climates or wind regions where it is questionable whether the tgerrgal sealirrg ° ° o ° ° ° ° o
adhesive will activate to seal the shingles, the shingles can be hand -sealed'. Two, 1-ipea 0. °
diameter (25.4 mm) spots of cement should be placed under each shingle (Ten per shingle),
spaced as shown In Tables 13A.
6.3.3 Laminated Shingles — Duration® Premium, TruDefinition® DurationOD,
TruDeflnitiono Duration® Storm, TruDeflnttion® Durations MAX:
For roof slopes of 2:12 up to 21:12 (16.67% or 90 up to 175% or 600), each shingle must be
fastened to the roof deck using a minimum of four fasteners, spaced as shown in Tables 4-7.
For roof slopes over 21:12 (175% or 60°), six fasteners must be used, spaced as shown in
Tables 4-7.
Fasteners must be located 6-1/8 inches (157 mm) above the butt edge of the shingles (center
of the SureNail® fastening area).
Maximum exposure to the weather must be 5 % t'/8 jro (143 t 3 mm)
In colder climates or wind regions where it is questionable whether the thermal -sealing
adhesive will activate to seal the shingles, the shingles can be hand -sealed. Four, 1-inch
diameter (25A mm) spots of cement should be placed under the exposed portion of the
shingle, spaced 1 — 2 inches (25 — 51 mm) from each end of the shingle and two spots must
be evenly spaced in between.
Page 5 of 30
� MIAMI-DADE COUNTY
MIMI®
' PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.rniamidade.aov/economy
Polyglass USA Inc.
I I11 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
This NOA is being issued under the applicable Hiles and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if 4 j$ •
determined by Miami -Dade County Product Control Section that this product or material fails to meet thl ,raWlremeptg....
of the applicable building code. '
This product is approved as described herein, and has been designed to comply with the Florida Building (Ode
including the High Velocity Hurricane Zone of the Florida Building Code. • ""'
DESCRIPTION: Polyglass Polystick Underlayments •" :::"
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, C yo.61tate and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein .. ....: •
RENEWAL of this NOA shall be considered after a renewal application has been filed and therehas bgMne change
in the applicable building code negatively affecting the performance of this product. '
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.17-0614.22 and consists of pages 1 through 7.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 21-0602.14
Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 1 of 7
ir
t
v a
0000s6
0
0 0 0
0
0000
0 00
0
0
0000e9
0090:
06ee90 ,
0
0 0
0
000000
000000
0 0
0 0
0000
000000
0 0
00000
0
0000
0 0
00000
0 0
000000
000000
0 0
000000
0
00 00
o
,:�
boesoe
0
0 0 0
0 0 0
0 0
00 0
0 0
000000
0 0 0
0 •e
s' • e -
e •:o
00 0
ROOFING COMPONENT APPROVAL
Cateeorv: Roofing
Sub-Cateeorv: Underlayment
Material: SBS, APP
PRODUCTS DESCRIPTION:
Test Product
Product
Dimensions
Specification Description
Polystick iR-Xe
65' x 3' Or 33.4' x
ASTM D 1970 A fine granular/sand top surface self -adhering, APP
Manufacturing
3
polymer modified, fiberglass reinforced, bituminous sheet
Location #1 & #2
material for use as an underlayment in sloped roof
60 mils thick
assemblies. Designed as an ice & rain shield.
Polystick TU Max
65'8" x 31-3/8"
TAS 103 and A rubberized asphalt self -adhering, polyester reinforced
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed as a a roof file
Location #1 & #2
underlayment.
Polystick TU P
32'10" x 3'3 3/s"
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granulawS"ae • •
• •
designed for use as a tie rodurulkaymenl�
Location #2
.. ..
Polystick TU Plus
65' x 313/8"
TAS 103 and A rubberized asphalt self-adNCrt4g; glass-9btt/polyester•
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing me$t9frMt. Designed as a mOW..:
Manufacturing
roofing and roof file underlaym* * * • : • • • '
.... . .....
Location #1 & #2
•••••; ,,;, ••••••
Polystick MTS
65'8" x 31?4"
TAS 103 A homogeneous, rubberized asphalt waterproofing '
Manufacturing
60 mils thick
membrane, glass fiber reinfo►cedwith po]WlcSrnic fil" ..:.
Location #2
on the upper surface for use tls aq Vderlaymetrt for mf1a2. • ;
roofing, roof tile, slate tiles anfl shiflgle adgrlayment'
Polystick MTS Plus
65'8" x 3'3 '/s"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyclefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G 32'10" x 3'3-3/." TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2 use in roof file underlayment systems.
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
NOA No.: 21-0602.14
Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 2 of 7
3
p � gip'
� � _ .: .. •
000000
ooee
s 0 "'+�t `• -
0
0000
a ee
0
a
000000
ee00
090.000, t'
o s
e
oeasee
00000e'
t
0 0
e o
soop
000000
0; o
00000
0
ooee
0 0
'
00000
0 0
006000
e00000
0 0
000000
0
00 00
0
0 0 0
00 0
Test Aeencv
Trinity ( ERD
LABELING:
EVIDENCE SUBMITTED
Test Identifier Test Name/Report
P37300.10.11
P37590.07.13-1
P45270.05.14
P46520.10.14
P44360.10.14
P43290.10.14
PLYG-SC 10130.06.16-3
PLYG-10130.06.16-1
PLYG-SC 10130.09.16
PLYG-SC13035.08.17
TAS 110/ASTM D4798 & D 1970
ASTM D6164
TAS 103, TAS 110 & ASTM D 1623
ASTM D 1623
TAS 103 & TAS 110
ASTM D 1970 & TAS 110
TAS 103 & TAS 110
ASTM D 1970 & TAS 110
ASTM D 1623
TAS 103 & ASTM D4798
Date
10/19/11
07/02/13
05/12/14
10/03/14
10/07/14
10/17/14
06/27/16
06/27/16
09/22/16
10/32/17
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
0 0 0 0
0 0
MIAMM=E COUNTY
0 0 0000 0000e0
e 0 0 °
oo°o e
0 0
O.ONOO OoOe 000000
0
000000 O O O
BUILDING PERMIT REQUIREMENTS:
O V 0 0 0 0
0000 O O O O
O O 000000
0 0 0 0 V • 0 0 0 6
e 0 e e e e ° ° 000000
Application for building permit shall be accompanied by copies of the following:
00 so 0 0000°0
° 0 0 ° ° 0 ° o °
® ® ° 0
1. This Notice of Acceptance.
° ° ° 000000
e o 0
2. Any other documents required by the Building Official or applicable building code in
0 0 0 oe o 0
0
orl retb }$roperl .evaluate tip' ° ° °
installation of this materials.
a 0
e o0
°
NOA No.: 21-0602.14
MIAMM ME COUNTY Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 3 of 7
0000
0 O
000000 0000 O 0
0 o a a
0 oaeo 0 00
0 0
600000 0600 0e0e00
0
0 o a ee0000
0000vo
0 0 0 0 0000
000080 0 0
a0aoe a 0000
0 0
00000 0 a 006000
000089 0 0
0000vo 0 00 00
0
0 0 000000
0 0 0 0
000000 0 oe 0 0
0 0 a
o a 00 0 a 0
aooeeo
o
e o 0
00 0
INSTALLATION PROCEDURES:
Deck Type l: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type IT or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS
or Polystick NITS Plus, self -adhered.
Surfacing: See General Limitations Below.
Deck Type l:
Wood, non -insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E(2):
Anchor sheet mechanically fastened to deck, membrane adhered O ° ° O
° °
Anchor/Base Sheet:
O O 0 0 0 0 0 0 0 0 00
One or more plies of ASTM D 226 Type H or ASTM D 2626. ° ° ° O
0 0 O 0000
Fastening:
°
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a-miRimum. 4191 ecad lap. (U. °: °
base sheet only) ° ° ° ° ° ° O O O
Membrane:
O O O O O O
Elastoflex S6 G, hot asphalt applied ° 0000 ° : ° ° ° ° ° 00000
Surfacing:
See General Limitations Below. O O O O° O O O O°: O°°
O o 000000
O O 0 0 O 0 0 0 0: 0
00000o O
Deck Type 1:
°
O O O O
° O 00 O 000000
° °
O O O O O O O
Wood, non -insulated ° O O O O O O O°
00 O 00 O O O
Deck Description:
Min. 19/32" plywood or wood plank : ° 00 °
System Type E(3):
Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet:
One or more plies of ASTM D 226 Type H or ASTM D 2626.
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet:
Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane:
Polystick TU Plus, self -adhered.
Surfacing:
See General Limitations Below.
NOA No.: 21-0602.14
MADe COON W Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 4 of 7
JL
0000
O O
000000
0000
O 0
0
O O O
O
0000
O 00
0
0
000000
0000
00000:o., _
o -
0 0
0
000000
000000
0 0
0 0
0000
000000
0 0
00000
0
0000
0 0
00000
0 0
0000e0
000000
O 0
000000
0
00 00
0
0
0
0000eo
0
0 0 a
000000
0 00
0 0
0 0 0
0 0
00 O
0 0
000000
0 0 0
0 0
0 00
0 00
0 0 0
00 0
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to
lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment. °
00000
° ° °
GENERAL LDaTATIONS:
1.
2.
3.
4.
5.
Fire classification is not part of this acceptance.
000000
°
°
°
° ° ° °
° °
° 0000
°
0000 ° ° ° °
Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic ogles, VbocrAiakes° ° ° ° °
and shingles, non-structural metal roofing, roof tile systems and quarry slate roof asslieg. °
° ° °°°°°
° ° ° ° ° °
Polystick TU P may be used in all the previous assemblies listed except metal roofing° ° ° ° 000000
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing°W� roof tile systems. ° °
Polystick TU Max may be used in non-structural metal roofing and roof tiles stems ° 00 ° ° ° ° ° °
° ° °
Y Y g v °°° ° °° :°°°°:
Elastoflex S6 G may be used in roof tile systems only. 00 ° 00 ° ° °
° ° °
Deck requirements shall be in compliance with applicable building code. 660
Polystick IR Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS
Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities.
Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS
Plus shall not be adhered directly over a pre-existing roof membrane as a recover system.
° ° °
°
° ° ° 00 °
°
° ° ° ° ° °
°
°
° ° O °
6. Polystick IR Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS
Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below
after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the
preceeding maximum time limitations.
Exposure Limitations (Days)
Polystick
MTS
Polystick
llt Xe
Elastoflex
S6 G
Polystick
TU Plus
Polystick
TU P
Polystick
TU Max
Polystick
MTS Plus
Winter Haven FL
180
90
180
180
180
180
180
Hazelton PA
N/A
90
N/A
180
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 21-0602.14
Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 5 of 7
0000
0 O
000000 0000 O 0
O O O O
p 0000 O 00
0 O
000000 0000 000000
0
0 0 O 000000
000000
i
O O O O 0000
.000000 O O -
00000`
O O
000000 0. o..
000000 O 00 0.0
0 O 00000•
000000 O 00 0 �O
O O OO O O 0
000000 O O O
0 O 0 00 0 00
O O O
00 O
1
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically
fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystick
System (E3)
Profile
MTS
S6 G
Polystick TU P
TU Max
MTS Plus
MTS Plus with
TU Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:12
6:12
without battens
Profiled
Prohibited
4:12
6:12
6:12
4:12
6:12
Tile
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved.Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battos gr requiradt 4key shall.....
be utilized during loading and installation of tiles. • • • -
.
10. Care should betaken during the loading procedure to keep foot traffic to a minimum and.Uavoid dropping of the
directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading prooedure -. two:tiles lahl•
4 .es.
perpendicular to slope followed by a maximum four file stack parallel to the slope, for z tote t:l' of 6 —• for all.....
underlayments except Polystick MTS which shall be loaded onto battens. .....
A&&
bof Deck prelarc4 will,
POIYSnCKIU Pus
Hooting Tiles
(6 Max. Per Stack)
12
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus,
Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice
of Acceptance listing Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick
MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the
Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided
to detail compatibility of the products, wind uplift resistance, and fire testing results.
NOA No.: 21-0602.14
MIAMI-DADE COUNTY Expiration Date: 09/13/22
r Approval Date: 08/26/21
Page 6 of 7
A r }
O 0
O
0 0 O
0 0000
O 00
0 0
000000 0000
000000
0 t
0wo s
aaooeo
o �
00000
�seo.
0 0
00000 0 o
eoeeee
000000
000000 0
00 00
O
0 p
000000
0
0 0 O
000000 0 00
0 0
O 0 0
0 0 00 O
O O
000000
0 e O
O 0 O 00
0 00
0 0 0
00 O
q •
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 applied in between the
application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading file on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10. 0069
s s
6. Battens and/or Counter -battens, as required by the file manufacturers NOA, must be u ed mntall project? for 00000
pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/a"`1 o,.g*recauuo�s°°should be °
taken, such as the use of battens to prevent tile sliding during the loading process. O 0 , a ° ° 0 0 ° " °
7. Minimum cure time after membrane installation & before loading of roofing tiles is Foirr-PSight (,W JJ§Urs. CO O O OO
°
0000 9 00004
8. Polystick membranes may not be used in any exposed application such as crickets, expmedjyalleo• ® °°° y 9000°°&, or gxpose4 ° o ° ° °
roof to wall details. ® 000000
00000 0
9. Repair of Polystick membranes is to be accomplished by applying Polyglass POLYPjU;S§, XtraFlex 50 °
°
Premium Modified Wet/Dry Cement or Polyglass PG 500 to the area in need of repaiz, folbiwed by a, patch of We ' ° o
Polystick material of like kind should be set and hand rolled in place over the area ne8ding guch rqAair.°Patchigg ° ° °
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such°a. Ay so that
water will run parallel to or over the top of all laps of the patch.
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 8944563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 8944563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 21-0602.14
Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 7 of 7
noon
0 s
GOOD"
0,000
soe. i
G
O000
000060
6000
e'GOOO*
o
O O
g
006000
00000a
o
s
.GOOD.
0
aa0oes
00000
a
Good
o a
00000
0 0
000*00
0900O0
0 0
O60000
O
00 ?O,
00
0
000000 .
0
..
a .o; o '' ... .. ,� •
000000
0 OO
0., O
0 e
DO a
d. s
O00000
G it
e 0 0
a ss
0 0
e 0 0
eo s
f
Miami Shores Village - BUILDING DEPARTMENT
10050 NE 2 Ave Miami Shores, FL 33138
305-795-2204 www.msvfl.gov
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR
EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION
553.844 F.S.
To: Miami Shores Village Building Department
10050 NE 2"d Ave
Miami Shores, FI 33138
Re: Owner's I
Date: —2-
Property Address: /ylS ,f/_ qG S;
Roofing Permit Number:
ffDe�ildinracial:
I /9lu1✓Syvcertify that I am not required to retrofit the roof
to will connections of my building because:
�'fhe just valuation for the structure for purpose of ad valorem taxation is less than
$300,000.00. Please attach proof of ad valorem taxation.
❑ The bui ding was constructed in compliance with the provisions of the Florida Building Code
(F I h th pro isions of 1994 edition of the South Florida Building Code (1994 SFBC)
Ie-f- �A1�� Awo-
56ahWe 7 Print Name
State of Florid�f, Miami Dade County
The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the
abRve pro erty mentioned. Sworn to and subscribed before me this _day of
20J2i
•'d'+" CATHERINE A. DUFFIN
Notary Public, State of Florida at Large u fg`.. 4 „I C NpHH 0895%2
o:
'�;Eo� t� � • anndad , Nolery Public UndewNers
• When the just valuation of the structure for purpose 5FadvaTorem taxation is equal to
or more than $300,000.00, and the building was not constructed with FBC nor a 1994
SFBC. Then you must provide a building application from a General Contractor for the
Roof to Wall connection Hurricane Mitigation.
For Forms and Applications click here:
http://bidg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia
miShoresVillage
Rev01 142021 Owner affidavit of exemption Page 1 of 1
OFFICE OF THE PROPERTY APPRAISER
Summary Report
Property Information
Folio:
11-3206-014-3790
Property Address:
1235 NE 96 ST
Miami Shores, FL 33138-2553
Owner
ROBERT F WILLIAMSON JR &W
JULIE
Mailing Address
1235 NE 96 ST
MIAMI, FL 33138-2553
PA Primary Zone
1400 SGL FAMILY - 3001-3250 SQ
Primary Land Use
0101 RESIDENTIAL -SINGLE
FAMILY:1 UNIT
Beds I Baths I Half
4 / 310
Floors
2
Living Units
1
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
2,741 Sq.Ft
Lot Size
20,250 Sq.Ft
Year Built
Multiple (See Building Info.)
Assessment Information
Year
2021
2020
2019
Land Value
$765,716
$765.716
$765,716
Building Value
$191,404
$191,441
$191,478
XF Value
$20,810
$20.947
$21,103
Market Value
$977,930
$978,104
$978,297
Assessed Value
$301,477
$297,315
$290,631
Benefits Information
Benefit
Type
2021
2020
2019
Save Our Homes
Cap
Assessment
Reduction
$676,453
$680,789
$687,666
Homestead
Exemption
$25,000
$25,000
$25,000
Second Homestead
Exemption
$25,000
$25.000
$25,000
Note: Not all benefits are applicable to ail Taxable Values (i.e. County, School
Board, City, Regional).
13hort Legal Description
5-6 53 42
MIAMI SHORES SEC 3 PB 10-37
LOT 89&10 BLK 83
LOT SIZE IRREGULAR
OR 9749-1620
Generated On : 4/11/2022
Taxable Value Information
2021
2020
2019
County
Exemption Value
1 $50.000
$50.000
$50,000
Taxable Value
1 $251,477
$247.315
$240,631
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
$276,477
$272,315
$265,631
city
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$251,477
$247.315
$240,631
Regional
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$251,477
$247,315
$240,631
Sales Information
Previous Sale
Price
OR Book -Page
Qualification Description
07/01/1977
$127,500
09749-1620
Sales which are quallfied
07/01/1971
$73,000
00000-00000
1 Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:flw .miamidade.gov/info/discialmor.asp
Version:
Miami Shores Village - BUILDING DEPARTMENT
10050 NE 2 Ave Miami Shores, FL 33138
305-795-2204 www.msvfl.ciov
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS
NOTIFICATION FOR ROOFING CONSIDERATIONS
R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to
provide the owner with the required roofing permit, and to explain to the owner the content
of the section. The provisions of Section R4402 govern the minimum requirements and
standards of the industry for roofing system installations. Additionally, the following items
should be addressed as part of the agreement between the owner ant the contractor. The
owner's initial in the designated space indicates that the item has been explained.
1. Aesthetics -Workmanship: the workmanship provisions of Section R4402 are
f r he purpose of providing that the roof system meets the wind resistance and water
instruction performance standards. Aesthetics (appearance) are not a consideration with
respect to workmanship provisions. Aesthetic issues such as color or architectural
appearance, that are not part of a zoning code, should be addressed as part of the
a e me t between the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck
y have to be renailed in accordance with the current provisions of Section R4403. (The
ro deck is usually concealed prior to removing the existing roof system).
3. Common roofs: Common roofs are those which have no visible delineation
tw en neighboring units (i.e., townhouses, condominiums, etc.) In buildings with
common roofs, the roofing contractor and/or owner should notify the occupants of
adj ent units of roofing to be performed.
4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the
r f decking can be viewed from below. The owner may wish to maintain the architectural
appearance; therefore, roofing nail penetration of the underside of the decking may not be
acc table. This provides the option of maintaining the appearance.
5. Ponding water: The current roof system and/or deck of the building may not
ain well and may cause water to pond (accumulate) in low-lying areas of the roof.
Pounding can be an indication of structural distress and may require the review of a
professional structural engineer. Pounding may shorten the life expectancy and
performance of the new roofing system. Pounding conditions may not be evident until the
original roofing system is removed. Pounding conditions should be corrected.
Rev01 142021 Owners roofing consideration Page 1 of 2
Miami Shores Village - BUILDING DEPARTMENT
10050 NE 2 Ave Miami Shores, FL 33138
305-795-2204 www.msvfl.Aov
�rffow scuppers (wall outlets): It is required that rainwater flows off so that
verloaded from a buildup of water. Perimeter/edge wall or other roof
extension may block this discharge if overflow scuppers (wall outlets) are not provided. It
may be necessary to install overflow scuppers in accordance with the requirements of
Sections R4402, R4403 and R4413.
7. Ventilation: Most roof structures should have some ability to vent natural
airflow through the interior of the structure assembly (the building itself). The existing
amount of attic ventilation shall not be reduced. It may be beneficial to consider additional
hich can result in ext nding the service life of th oof.
Owner/Agent'/5711 nature ate C tractor Signature Da e
For Forms andlications click here:
http://bldg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia
miShoresVillage
ReV01 142021 Owners roofing consideration Page 2 of 2
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1625
HIGH -VELOCITY HURRICANE ZONES —UNIFORM PERMIT APPLICATION
Florida Building Code 7th Edition (2020)
High -Velocity Hurricane Zone Uniform Permit Application Form
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW:
Roof System
Required Sections of the
Permit Application Form
Attachments Required
See List Below
Low Slope Application
A,B,C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A,B,C
4,5,6,7
Asphaltic Shingles
A,B,D
1,2,4,5,6,7
Concrete or Clay Tile
A,B,D,E
1,2,3,4,5,6,7
Metal Roofs
A,B,D
1,2,3,4,5,6,7
Wood Shingles and Shakes
A,B,D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED:
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
FLORIDA BUILDING CODE — BUILDING, 7th EDITION (2020) 473