Loading...
RF-10-22-2569Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 11/09/2022 Location Address Parcel Number 550 NE 94TH ST, Miami Shores, FL 33138 1132060140940 Contacts ............_. Permit NO.: RF-10-22-2569 Permit Type: Roof -Work Classification: Tile Permit Status: Approved Expiration: 05/09/2023 FLORENCIA MARC[ Owner VARMO CONSTRUCTION, LLC Applicant 550 NE 94 ST WILLIAM H VARGAS 12354 SW 252 TER, HOMESTEAD, FL 33032 permitsflorida@gmall.com VARMO CONSTRUCTION LLC Contractor WILLIAM VARGAS 124354 252 TER, HOMESTEAD, FL 33032 Business: 3052448712 williamhvargas@hotmail.com Mobile: 3052448712 Description: RE ROOF TEAR OFF OLD TILE AND BUILD UP ROOFS, REPLACE ROTTEN WOOD, RE NOIL EXIST WOOD, DRY IN #30 SLOPE, INSTALL POLYSTICK . INSTALL TILE FLOT FODM SYSTEM. FLAT 2#75 METALS PERIMETER AND TORCH Fees Amount Application Fee - Other $50.00 CCF $16.80 DBPR Fee $9.41 DCA Fee $6.27 Education Surcharge $8.40 Permit Fee (Manual) $524.67 Permit Fee (Manual) $52.70 Scanning Fee (Manual) $12.00 Technology Fee (Manual) $62.74 Total: $742.99 Inspection Requests: Valuation: $ 28,000.00 3(15-762-4949 Total Sq Feet: 3,411.00 Payments Date Paid Amt Paid Total Fees $742.99 Cash 10/11/2022 $50.00 Credit Card 11/09/2022 $692.99 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating con,*ction and zoning. Futhermore, I authorize the above named contractor to do the work stated. , i/, 2 Z, Authorized Signature: Owner / Applicant / Contractor I Agent November 09, 2022 Page 2 of 2 Miami Shores Village �C-,P-JvE Building Department pC1112022 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 $Y; INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ROOFING ❑PLUMBING ❑ MECHANICAL ❑ CHANGE OF JOB ADDRESS: CONTRACTOR 550 N.-E . 94 FttBC 20� Master Permit No.Rf --—10 —22,— CI5V 1 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CANCELLATION ❑ SHOP DRAWINGS ­5T2E4C 7- 313 206 0/S4 499'A0 Is the Building Historically Designated:Yes NO X Occupancy Type:- Load: Construction Type: Flood Zone: BFE: FIFE: w,f /•/Ac2/ OWNER:Name(F,,eeeS•.i,•m,,--ple_TTitleholder):'/FLOI•�Wc/A Phone#: Address: / r • E�1 T' AS550 City: 141.6 f" 1 / �9 sHO46.S State: FL ' Zip: 33/ 3$ Tenant/Lessee Name: NZA Phone#: N1A Email: CONTRACTOR: Company Name: ya12MO cer45 �L� Phone#: a V' 2T S��Z Address: I23V- s.w. 25Z /Ez/1-AC6 �/oME�Ee/�, �L, 33032. Email: �%(n7iitx 6'Ior-/ do- &_ 9 f-f # GpM Qualifier Name: Wit C /AM i�• a 2 G1'9/S Phone#(/3o5) zy-tL State Certification or Registration #: eee /33 OOQIo Certificate of Competency #: DESIGNER: Architect/Engineer: Address: City: State: uZip: Value of Work for this Permit: $ Z ?j 000.00 Square/Linear Footage of Work: 3 / // Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace ❑ Demolition Description of Work: /?E' 400F 702 O}'/ ee0 j /Le 40 3v/4-T d� /UCFS /Ze AMC ltvl7W wccg + 126 /YD/(. i Xj37. wcc.J/ -* 3a 51XPE /NSrAU A%G S' IPJ57'AGL T/CE F(07 F'eO-fl�3r�_r1 707.2# ar NE771c.s P644"e;rOL 44P 704df Specify color of color thru til • WI- / 7X C(41 Submittal Fee $ �b (� Permit Fee $ �,CCF $ 6l .CO/CC Scanning Fee $ �� -•� DCA Fee $ I�, j 17 DBPR $ G •4.I. Notar Technology Fee $ ��• 1-1 Training/Education Fee $ Double Fee Structural Reviews $ —_ P&Z Review $ Bond ; TOTAL FEE NOW DUE $ (Revised04/05/2022) Bonding Company's Name (if applica Bonding Company's Address 111A City State Zip Mortgage Lender's Name (if applicable) AfA Mortgage Lender's Address A1J,b City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be apprqlXrlvnd a reinspection fee will be charged. Z� OWNER or AGENT The foregoing instrument was acknowledged before me this 30 day of 1hE0% , 20 ZZ by )CLO/LEr c /q MACIL I� ,,,rho is personally known to me or who has produced 44 016 M1 as identification and who did take an oath. pi16V�6R'f NOTARY PUBLIC: Print: ii `' a'• MERCEDES BENCOSME Seal: X': Notary Public - State of Florida y Commission # HH 106324 or r Bo My Camm. Expires Mar 2J, 2r Banded through National ;o Assn ry . APPROVED BY The foregoing instrument was acknowledged before me this 30 day of $0% 20 ?I- by pldio-4 V,614bg (who is personallyknowntg me or who has produced identification and who did take an oath. NOTARY PUBLIC: u� z, _i "5zg.,t i e # i i as Seal: MERCEDESBENCOSM_ Notary Public - State of Flu ca Commission # HH 10632� - ******************* r*17rp *Nfk GQtWN•xLMRir�nF M#w3cf*iA3B *******•**** Bonded through National Notary Assn. Plans Examiner Zoning (Revised02/24/2014) Structural Review Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: ZIZ-Z- Z 10050 NE 2nd Ave Miami Shores, A 33138 Re: Owner's Name: FLO/Z EYJG !A Mh /LC ( M<1 C/L l Property Address: $$o rl. "E • q st lu-c % Roofing Permit Number: Dear Building Official: I r,10 iLE r4G ,�A IA r A2L I certify that I am not required to retrofit the roof to wall connections of my building because: XThe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 191"ion of the South Florida Building Code (1994 SFBC) FLo/LC�c ��k /YA/zC I f-M c 2 Signature I g 7., MERCEDEBBENC0fF Print Name '+°�`��+��": NotaryPublic -State of Florida i� Commissian q HH 106324 My Comm. Expires Mar 21, 2025 State of Florida Bonded through National Notary Assn. County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this 'W4- ZL day of Z. ez 7— Notary Public, Sate of Florida at Large _ da—zi When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00. and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Miligation. Revised on 5/212009 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.aov SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. )rL Aesthetics -Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. � L. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. L Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. � t Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. t Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. Rev01 142021 Owners roofing consideration Page 1 of 2 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.gov 6. I Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. 1F�_ Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional ventin ' 6 can result in extending the service life of the roof. I , 9/z'/ZZ r/Agent's Sign2`ture Cont 112212z Date For Forms and Applications click here: http://bldg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia miShoresVillage RevOI 142021 Owners roofing consideration Page 2 of 2 23/092022, 10:11 Property Search Application - Miami -Dade County Address Owner Name Folio SEARCH: 550 ne 94 street Back to Search Results PROPERTY INFORMATION Folio: 11-3206-014-0940 Sub -Division: MIAMI SHORES SEC 2 Property Address 550 NE 94 ST Owner FLORENCIA MARCI Mailing Address 550 NE 94 ST MIAMI SHORES, FL 33138 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SO Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY:1 UNIT Beds / Baths / Half 2/2/0 Floors 1 Living Units 1 Suite D hitps://www.niimidade.gov/Apps/PA/propertyseuch/#/ i 23/09/2022. 10:13 Properq Search Application - Miami -Dade County Property Search Help Property Taxes Report Discrepancies Report Homestead Fraud Special Taxing Districts and Other Non -Ad valorem Assessments Tax Comparison Tax Estimator' TRIM Notice Value Adjustment Board ASSESSMENT INFORMATION Year\ 2022 2021 2020 Land Value v $450,974 $308,203 $308,203 vv Building Value $236,018 $179,224 $180,670 Extra Feature Value $26,795 $27,126 $27,456 Market Value $713,787 $514,553 $516,329 Assessed Value $713,787 $514,553 $516,329 TAXABLE VALUE INFORMATION 2022 2021 2020 COUNTY Exemption Value $0 $0 $0 Taxable Value $713,787 $514,553 $516,329 SCHOOLBOARD Exemption Value $0 $0 $0 Taxable Value $713,787 $514,553 $516,329 CITY Exemption Value $0 $0 $0 Taxable Value $713,787 $514,553 $516,329 REGIONAL Exemption Value $0 $0 $0 Taxable Value $713,787 $514,553 $516,329 BENEFITS INFORMATION Benefit Type 2022 2021 2020 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). FULL LEGAL DESCRIPTION Mips://www.miamidade..guv/Apps/PA/propertysearch/l// 3/8 23109/2022,10:11 Property Search Application - Miami -Dade County MIAMI SHORES SEC 2 PB 10-37 LOTS 6 & E112 LOT 7 BLK 56 LOT SIZE 75.000 X 128 OR 19704-0242 05 2001 1 COC 26499-1693 06 2008 1 SALES INFORMATION Previous Sale Price OR Book -Page Qualification Description Previous Owner 1 Previous Owner 2 09/30/2021 $875,000 32817-2026 Corrective, tax or QCD; min consideration JOSEPH R PRICE VICTOR J ZABORSKY 09/30/2021 $100 32803-2539 Corrective, tax or QCD; min consideration JOSEPH R PRICE JTRS VICTOR J ZABORSKY JTRS 08/19/2013 $100 29360-1665 Unable to process sale due to deed errors JOSEPH R PRICE JTRS 06/01/2008 $715,000 26499-1693 Sales which are qualified DEANNA SINGER 05/01/2001 $387,000 19704-0242 Sales which are qualified 07/01/1997 $163.800 17722-3977 Sales which are qualified 02/01/1995 $147,500 16693-2394 Sales which are qualified 08/01/1991 $155,000 15170-2652 Sales which are qualified 05101/1981 $93.000 11114-2261 Sales which are qualified For more information about the Department of Revenue's Sales Qualification Codes. 2022 2021 2020 LAND INFORMATION Land Use Muni Zone GENERAL R-17.5. R-18.5 BUILDING INFORMATION Building Number Sub Area 1 1 2 1 3 1 4 Current Building Sketches Available EXTRA FEATURES PA Zone Unit Type Units Cale Value 1000 - SGL FAMILY - 2101-2300 SO Front Ft. 75.00 $450,974 Year Built Actual Sq.Ft Living Sq.Ft. Adj Sq.Ft. Cale Value 1939 2.530 2,029 2,083 $197,281 1957 253 0 84 $7,956 1970 81 81 81 $7,672 1974 366 366 244 $23.109 https://www.miamidade.gov/Apps/PA/pmpertyseuch/#/ 4/8 _P'_P�CF�ivLD ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Or,T .I ?filz BY: rTIL 1525 HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED RFLOW- Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 112,3,415,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Miami Shores Village B�i Depa*1,t CITY Zoning Dept. _ Dat-Building Dept. Da._Subject t0 rulcmance e COPY and Court rules and regulations. Permit# 15.36 FLORIDA BUILDING CODE— BUILDING, 5th EDITION (2014) t I Agreement. No further reproductions outhorimd. ' t I I I Copyright to, or licensed by, [CC (ALL RIGIIrS RESERVED); 8mmed by Elicter Palacio on Jun S. 2015 10:32:12 AM pursuant to Llceom ROOF ASSEMBLIES AND ROOFTOP STRUCTURES •• ■a i�■■MEMO ■■C�,Si■■■■■■■■,,�.■■a viks L� ■ N■►�■■fl'Si■■�9ifiii■■■■■■��►Ji■ ■ 11IM111111 EN ir�a a■a�w�■.■r.•■s.���e ems;■■■ ■ II d ■ ■lily■rS •LMAds— �ir'i��iii�l �I\ ■ ■ Ifl 1■iiiooi■�� miA0l�ir■■ FLORIDA BUILDING CODE - BUILDING, Sth EDITION (2014) v 15.37 Copyrighuo, or licensed by, ICC (ALL R1GIiTS RESERVED); accessed by Eliezer Palacio on Jun S. 2015 10:32:12 AM Pursuant ro License Agmement. No further mpmductions aulhodred. „r•�T, .aura � .v: _;�.� s:.— p r �. sip., i~ "}•g� �ncr. frn� - 4 ROOF ASSEMBLIES Alba- ROOFTOP STRUCTURES _. y _ Florida Building Coate 5th Edition (2014) high -Velocity Hurricane Zone Uniform Permit Application Form. 2�22 ;Orin 1p��ir Slope Application) specific roof assembly components and iden po triy manufacturer fl of a component is, not used, -identifj as "NA ”) ll 1 1 1 1 1 .a• 1 7w System Manufacturer 017190 Product Approval �No.; ofie A • Design Wind Pressures,. From RAS 128 or Calculations: PI: P�: � p Y T Max. Design Pressure, from the specific product approval system: ,ji • Deck.?4 y woa Two' I. Slope: O AnchodBase Sheet & No. of Pty(s): Anchor/Base:Shaet Fastener/Bonding Material: 0 A Insulation Base Layer. Base Insulation Size and Thiokness: Base Insulation -Fastener/Bonding Material: PIA Top Insulation Layer; Top Insulation Size and Thickness: Top insulation Fastener/Bonding Material: lA Base Sheet(s) &.No, of plyw.�.�iQ,�� . w NSA Ply Sheets & No. of Ply(s): Top Ply Fastener/Sonding Material: WOr ATJ#blr Surfacing: [go � �� I� - -, P� M Fastener Spacing for Anchor/Base Sheet Attachment: } Field: 1oc ° @ Lap, # Rows @° oc Perimeter.AZocLa - 3 G� p,# Rows @ � oc seg'v& p Comer. oc @ Lap; # Rows, @ " oc Comer 1 Illustrate Components Noted and Details -as Applicable: 9 Woodblooldrig, Gutter, Edge TerminationStripppping, Flashing, 1 Continuous Cleat, Cant'Strip, Base Flashing, Counterfiashing, 1 Coping, Etc. I Indicate: Meats Roof Height, Parapet Height, Freight of Base Flashing, Component Material, Material Thickness, Fastener Type. Fastener Spacing or Submit Manufacturers Details that 1 Comply with. RAS 'I I I and Cholbr 16. R Number of Fasteners Per Insulation Field Perimeter -14 r�a�: � N6�1 i 18.38 FLORIDA BUILDING CODE— BUILDING, MENTION (2014) � fin 1 ; C0PYd ltt.to, 0efiCe=d by. 1CC. V L RfMM *W% RV�:D� aoass.cd by-9 ftedc on )wt:8. 201510:32:12 AM puns w to } kam AgrasaM Ro AUtw rewWuWans wthosind. F.l.E. af 14_1ti.titG0% tj �10 FLORIDA INTERNATIONAL ��' 1 ENGINEERING, INC. Certification # 07-0612.11-State of Florida ca #27273 INSIGHT•INNOVATION•INrEGRATION ENTERE da International Engineering, Inc. 5 NW 167 St., Bay G-20, Miami, FL 33015 hone: (305) 378-1991-Fax• (305) 378-1997 j�ov 01 2022 FASTENER SPACING CALCULATIONS PER ASCE 7-16 & 7`h edition FBC (2020) *Given Data: Job address: 550 NE 94 St., Miami Shores, FL Roof Type: Low Slope (<1/2:12) Deck type: Wood Roof height:10 ft. Dimensions: 38' x 17' System Mfr.: GAF Materials NOA No.: 18-0919.12 System Type: E (2) Fastening Option #3 MDP is -52.5 psf; General Limitation #7 applies. *Data provided by Contractor. Roof Zones & Layout: Smaller Horizontal Dimension <2.4h, Interior Field F' does not exist. Smaller Dimension is >1.2h Exterior Field F, exists. In this case Exterior Field is so small it may be treated as Zone 2. Perimeter: 0.6h is 6 feet wide. Corner: Length 0.6h = 6 feet., Corner Width 0.2h = 2 ft., but can not be < 3 feet. Use 3 feet. See attached roof sketch for designated Roof Areas & Layout. There are no continuous parapets. Drainage calculations are not required. *Data provided by Contractor. Design Criteria: Exposure: C Wind Velocity (V): 175 mph Risk factor: II RAS 128 (Table 1). III. Roof Design Pressure (P): Per RAS 128 (Table 1). Interior Field: F1= -37 psf; F (Field) = -68 psf; Perimeter (Zone 2) = -84 psf; Corner (Zone 3) = -115 psf SEE ATTACHED SKETCH FOR DIMENSIONS, ZONES, & LAYOUT IV. Conclusion: Enhanced Fastener Spacing per RAS 117/137: System Being Rated: GAF NOA No.:18-0919.12; System Type E (2); MDP: -52.5 psf Fastening option #3 Width of Sheet: 39.37" Net width: 39.37-4 = 36.37/12 = 2.95 Net Length to make Square: 100/2.95 = 33.9 No. of Rows: 3 Fasteners per Row at lap:12/9 x 33.9= 45 Fasteners in the center of the sheet: 45 X 2= 90 Fasteners per Square: 49 x 3 =147 Fasteners per S.F.: 100/147 = 0.68 Fastener Value: 52.5 x 0.68 = 35.7 Fz: 9"oc @ 4" wide side lap and two (2) rows staggered @ 9"oc in the center of the sheet. Enhanced Fastener Density: Field: 35.7 x 144/64 x 8.9 = 9 inches. Perimeter: 35.7 x 144/84 x 8.9 = 6.9 inches. Scale down, use 6" inches. Corner: 35.7 x 144/115 x 7.1= 6.3 inches. Scale down, use 6 inches In accordance with the design criteria for wind criteria specified in ASCE 7-16, and the 7a' Edition of the Florida Building Code (2020); the use of this flat roof system is acceptable for this application. The Contractor may, for practical reasons, treat Zone F, as Zone 2 (Perimeter). Roof area abutting Sloped Roof shall be treated as Perimeter. Follow RAS 115 & Manufacturer's published installation instructions. Install NOA No.:18-0919.12 2475 Base sheets (for use w/Torch membrane) with approved 1.25" ring shank nails and 1-5/8" tin caps, as follows: 1. Field (Fl): 9"oc #60 VA' If�►�9"oc in three (3) staggered rows in the field of the sheet. 2. Perimeter�•�itc, i,9,e��ii��lap, 6"oc in three (3) staggered rows in the field of the sheet. 3. Corner 4 49 apt +t4�Lg V1v oc in four (4) staggered rows in the field of the sheet. ? No. 63107 • S r VMB Venkate'�: 0glD N. • �t�, (Florida Regist W011.NAL ■ ■ SEEN mmmm ,iww,mw ► wil%%m MENU MONO MEMO ■ ■ ■ ■ �ia!:s MEMO Ryan NOME aurW NONE �.�I■■ate;/SEES IF /.;■■mail ammo■ A !mmom ■mmmm "Um■ ■namm-m mmop somm-ArAm .,...,. zs:w■■i// ■ME■:NME■EW irISN ■misommooff ■mmom■liilim MENDEMEOND ■mmulumm!m■ mommummomm ■m■■ ■m■■ IEEE!!! ISMS■■■ IEEE!■■ 1■NNE■■ IEEE IEEE■!■ IMMENSE 1■MEN■■ 1■m■m■ OMENS ■EN■■ ■■■m■ 0 y Brown Fqn adan Voluntavy Wind Load Chaff _ :a. Perms: ftrt and, C{ j f�a�r r t in Amfdance With Fors'q 1 JnU"retatlan L For DM6hed One -and Two a SNekk S 30ftet Wlmd.170 rtph (3-second gust) { Expbsure.C" / Kd = b.851 Kzt =1.0 / Pressures are in P5F / i�Sot for use in Coastal (Exposure 'D' areas3 Using Ai#omrai=ie Strew Design methodology {p = 0:6w) /' sure C:ot ishal#:bgtdetermined according to► ASCE 7�-16 section 26J {Exposure Categories) Roof and W601 Zanb Chart Diagns Y Wan Pressure Chaff Fta t f a liht mart Qaie Rm* li K c t Hip Itd Uplift Chart :' •� sii t fry�1 3 '_ .. � fad r. '313 � •`' frit� ��` 4 �� fib+.: `ff li��i17 + wp� {Z'!� - �� 'Y �z-✓ l: ` MAN f Cw PLAN, 1E..l�` �} i PLAN q "a r {oAN j� instructions on flow to use these Charts: Determine Mean Roof Height, fir, which is top of roof for flat roofs or the mean roof height for pitched roof's. find your least horizontal dimension for your building, not including a overhang if it occurs. Calculate the value of, ®, ;10% of least horizontal dimension or 0,4 ^h, whichever is smaller, but not less than either 4% of least horizontal dimension or 3 feet. if your roof height is less than 30 feet, but not exactly 15, 20, or 25 feet, you will need to go to the next higher roof height. if your Mean Foof Height is higher than 30 feet, these charts do not apply. Review the diagram which illustrate the wall and roof zones and determine the wind zone In which the component Is loomed. Determine the tributary area of the components if the tributary area falls in between values, use the value of the smaller tributary area. Select the positive and negative wind pressures corresponding to the waif or roof zone where your component is located. Door pressures shown are for the most common door sizes and are worst case for heights <- 30 feet. W8108 PM UM For ADO R® Gafrage/Doff Preaums Mean Roof Hel 15 Ft 20 Et <= 30 Ft TributaryArea 10 20 35 50 100 20 35 50 100 500 Effective Wind Area positive negative Wall Positive Pressure 38.0 36.2 34.9 34.0 32.3 23 39.5 37.0 36.1 34.3 30.1 Width Height Zone 4 H .Lwe Pressure -41.2 39.5 -38.1 37.2 -35.5 37 -4L9 �40.5 39.5 -37.7 -33.5 8 8 38.6 -48.2 Zone 5 floe Pressure -SO.B -47.4 -�4.6 -42.9 39S 30 50.4 -,47.4 -45.6 -41.9 -33.5 i0 10 37.4 -45.7 Mean Roof Hei 25 Ft 30 I Ft 14 14 35.4 -41,8 Tdbuta Area 10 20 35 50 � a0F3nS W 100 5W 9 7 38.7 -48.3 Wall Positive Pressure 42.3 40.4 38.837.8 35.9 39 41.9 39.3 37.3 32.8 16 7 37.0 -45.0 Zone 4 Ne tive Pressure -0.8 -43.9 -42A -41.4 -39.5 -6 -45.7 .1 -43.1 -�41.1 36.5 3 7 A41.8 -54.6 Zone 5 Negative Pressure -56.6 11 -52.$ -49.7 -47.8 -43.9 38 -54.7 LL7 -4! -45,7 -36.5 6 7 I39.8 -50.fi Pane 2 of 3 ASDDESIDN WINO UPUFT FRESSURES IN PSF FOR ROOF SLOPE- TABLE 1 — MINUAUM s 07412 RISK CATEGORY 11 EXPOSURE CATEGORY'C' Roof F mNam Iona e.n INIEM 1 2 3 r 15' 37 G4 44 .115 >t5'ms2D .39 .fie 99 -122 XAsIZv•7n t >220IGcs2541 -it .94 .02 .74 .97 .128 -33 .78 .101 >3Dps95' .137 a 95'psdO 45 -78 .103 .141 >d0'msd5' 46 -SO -IDS -145 >d5'bsSD 47 82 .109 .148 >Sdbs55' 48 .B4 .111 .151 >55'm c60' .49 -r -113 -t54 MINIMUM ASO DESIGN WIND UPUFT PRESSURES IN PEP FOR ROOF SLOPE TABLE 2 — a 1172:12 RISK CATEGORY U EXPOSURE CATEGORY'D' N31 now Pn41t11n Zo1MA Gw14d15X1 1 2 J 1. _ ` hVv s 45 .T7 .102 .139 nd6 >IS gcffi A7 -dt -107 a2D ms25' -4S -8s .112 .152 >25't0s30' -so .67 -115 .157 r 3D'msJS 52 .90 •115 161 � >95'ms4' 50 .92 -121 .166 i >40'bs45' 54 -94 -124 .169 a d5'ms`A' .55 .96 •126 4T2 _ Job C .97 •128 /St14�lt�y s'_ .175 .130 '1n F Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County Section D (Steep Sloped Roof System) Roof System Manufacturer: Product Control Number: 4Sd),2j4 L 12-aopN4 L L G Z/- 0 SL2o.0 q Minimum Design Wind Pressures.. From Applicable RAS 127 Table or Calculations: Zone1: Zone 2e: Zone2n:lag Zone 2r:1 �(! Zone 3e: A Zone 3r: /�� Slope Range: >_ 2:12 to 5 4:12 Roof Shape: ® All Hip Roof ®>4:12to56:12 0>6:12to<12:12 ® Gable Roof or Partial Gable/Hip Roof Deck Type: iAlO Q� Underlayment Type: 3� �S7M ,� ZL�Tf,06 Roof Slope: 3 2. :12 / A Insulation: Fire Barrier: Af V J.S. Ridge Ventilation? Fastener Type & Spacing: 4I Ar C,, C la/f g iWtrJd Cap Sheet Type. to Mean Roof Height: 141 Cap Sheet Attachment: [0// Ad.#ai* �o cx A g _ Roof Covering: [JeAkO4 ' 146 Drip Edge Type & Size: 3 "" fA0Z 4raLV M.6ic. A41141CP Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County Section E (Tile Calculations) For Moment based tile systems, choose Method 1. Compare the values for M,with the values from Mf. If the Mf values are greater than or equal to the M, values for each area of the roof, then the tile attachment method is acceptable. Method 1* " Moment Based Tile Calculations per RAS 127" Enter positive uplift pressures when using this table ( Zone 1: 1[� 7 7 /j x A 0 317 = �S- 7 f) — Mg: 7' d3 = Ma )�' iou Product Approval Mf: 'n ( Zone 2e: x 1, Q ' fs = Z3. � I ) _ Mg: Q = Mr2e f s• Q Product Approval Mf: '/b� W/ ( Zone 2n: Op /08 x A Q.3I S = 17 3f-OL) — Mg: T• te3 = Mr2" UA Product Approval Mf: 40 (Zone2r: 108 xX 0.31-V J4,01.)—Mg: ?•b3 =Mr2, 26.15 Product Approval Mf: 60 ( Zone 3e: /t S x AOX f =34• G Z ) — Mg: 7'63 = Mr3* 14-3 f Product Approval Mf: 40 ( Zone 3r: 1?' 0 Q N x A #. 31a = �t 7 01 G ) — Mg: ?• 6J = Mr3, "q Product Approval Mf: go Tile attachment method: Alternate Tile attachment method: For Uplift Based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values for each area of the roof, then the tile attachment method is acceptable. Method 3* "Uplift Based Tile Calculations per RAS 127" (Zone 1: x L = x W = ) — (w) x cos B ) = Fri Product Approval F': (Zone 2e: x L = x W = ) — (w ) x cos 6 ) = Fr2e Product Approval F': (Zone 2n: x L = x W = ) — (w) x cos 6 ) = Fr2" Product Approval F': (Zone 2r: x L = x W = ) — (w) x cos 6 ) = Fr2r Product Approval F': (Zone 3e: x L = x W = ) — (w) x cos 9 ) = Fr3e Product Approval F': (Zone 3r: x L= x W = ) —(W) x cos 9 ) = For Product Approval F':, *Method 2 "Simplified Tile Calculations" only applicable in Broward County. Where to obtain Information Description Symbol Where to Find Design Pressure Zones 1, 2e, 2n, 2r,3e, 3r From the applicable Table in RAS- 127 or be an engineering analysis prepared by a PE based upon ASCE 7 Mean Roof Height H Job Site Roof Slope B Job Site Aerodynamic Multiplier 4 Product Approval/Notice of Acceptance Restoring Moment due to Gravity M Product Approval / Notice of Acceptance Attachment Resistance Mr Product Approval / Notice of Acceptance Required Moment Resistance M, Calculated Minimum Attachment Resistance F' Product Approval / Notice of Acceptance Required Uplift Resistance F, Calculated Average Tile Weight w Product Approval / Notice of Acceptance Tile Dimensions L=Length W= Width Product Approval / Notice of Acceptance All calculations must be submitted to the Building Official at the time of permit application. 04/04/2022. 11:02 Roofing Application Standard (RAS) No, 127-20 Procedure for Determining the Moment of Resistance and Minimum Chamcterisfic Resistance Load to Install a Tile System on a Building of a 3.2 Determine the angle (6) of roof slope, from Tables 13, Tables 4-6, Tables 7-9 or Tables 10.12, as applicable. n 3.3 Determine the length (1), vAdth (w) and avera'aa t o walghr (,W'r of tile , per Product Approval. 1 ... . _ .• ... 3.4 Determine the required uplift resishmce.(.7; per follow(rIy fDTnula; . F— IPr�xIx'tAI-W)Xeth0 ,. -. .. ........ 3.5 Compare the values for Fr with the values for F noted in the Product Approval. If the F values are greater than or equal to the Fr values, for each area of roof, then the the attachment method is acceptable. TABLE 1 — GABLE ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE. a2:12to s4:12 RISK CATEGORY 11 EXPOSURE CATEGORY'C" Roof Mean Haight Roof prossureZones 1 W020 2n, 2r and 3e 31! >is to MY -78 -114 -136 > 20' b e 25' -82 -120 -142 >2$4063t7 -86 -125 -148 >30'toasv -as -129 -153 >36*bs40' -91 -132 -157 >40'Ios45' -93 .136 -102 >4VID,50' -95 -139 -165 >WtosSS -97 -142 -169 >Wbs60' -98 -144 -17/ "JcA I COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany, NJ 07054 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T(786)315-2590 F (786) 315-2599 www.miamidade.eov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid®Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 15-1020.01 and consists of pages 1 through 67. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 1 of 67 No A 2 ROOFING SYSTEM APPROVAL Cateizory: Roofing Sub-Cateeory: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -105 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description GAFGLAS® Ply 4 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet (1 meter) Wide reinforced with fiberglass mat. Tri-Ply® Ply 4 Ply Sheet 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet (1 meter) Wide reinforced with fiberglass mat. GAFGLAS® 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet F1exPly' 6 (1 meter) Wide reinforced with fiberglass mat. �-- GAFGLAS' #75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet (1 meter) Wide reinforced with fiberglass mat. Tri-Ply® #75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet (1 meter) Wide reinforced with fiberglass mat. GAFGLAS® #80 Ultima" Base 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet Sheet (l meter) Wide reinforced with fiberglass mat. GAFGLAS® Stratavene 39.37" ASTM D4897 Smooth surfaced asphaltic perforated Perforated Venting Base Sheet (1 meter) Wide venting base sheet reinforced with fiberglass mat. GAFGLAS® Stratavene 39.37" ASTM D4897 Smooth surfaced asphaltic nailable venting Nailable Venting Base Sheet (1 meter) Wide base sheet reinforced with fiberglass mat. Bottom side surfaced with granules. Ruberoid® HW 25 Smooth 39.37" ASTM D6163 Smooth surfaced torch applied SBS base (1 meter) Wide or ply sheet reinforced with a fiberglass mat. Ruberoid® HW Smooth 39.37" ASTM D6164 Smooth surfaced torch applied SBS base (1 meter) Wide or ply sheet reinforced with a polyester mat. Ruberoid® HW Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. �,.. Ruberoid® HW Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced heat- (1 meter) Wide welded SBS cap sheet reinforced with a polyester mat. Ruberoid® HW Plus Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® HW Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced torch FR (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 2 of 67 Product Ruberoid® EnergyCapT' HW Plus Granule FR Ruberoid® Torch Smooth Tri-Ply® APP Smooth Membrane Ruberoid® Torch Granule Tri-Ply® APP Granule Cap Sheet Ruberoid® Torch Plus Granule FR Ruberoid® EnergyCapT" Torch Plus Granule FR Ruberoid® EnergyCap"' Torch Granule FR Ruberoid® 20 Smooth Ruberoid® 30 Granule Ruberoid® 30 Granule FR No A �3 Test Dimensions Specification 1 meter (39.37") Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (l meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (l meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide Ruberoid® 30 Plus Granule FR 39.37" (1 meter) Wide Ruberoid® Mop Granule 39.37" (1 meter) Wide Tri-Ply® SBS Granule Cap 39.37" Sheet (1 meter) Wide ASTM D6164 ASTM. D6222 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6222 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6163 ASTM D6164 ASTM D6164 Product Description Fire retardant granule surfaced heat - welded SBS cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT' EnergyCoteT" Elastomeric Coating. Smooth surfaced torch applied APP base or ply sheet reinforced with a polyester mat. Smooth surfaced torch applied APP cap, base or ply sheet reinforced with a polyester mat. Granule surfaced torch applied APP cap sheet reinforced with a polyester mat. Granule surfaced torch applied APP cap sheet reinforced with a polyester mat. Fire retardant granule surfaced torch applied APP cap sheet reinforced with a polyester mat. Fire retardant granule surfaced torch applied APP cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT® EnergyCote' Elastomeric Coating. Fire retardant granule surfaced torch applied APP cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT® EnergyCote' Elastomeric Coating. SBS polymer -modified asphalt base or ply sheet reinforced with a fiberglass mat. Granule surfaced mop applied SBS cap sheet reinforced with a fiberglass mat. Fire retardant granule surfaced mop applied SBS cap sheet reinforced with fiberglass mat. Fire retardant granule surfaced mop applied SBS cap sheet reinforced with fiberglass mat. Granule surfaced mop applied SBS cap sheet reinforced with a polyester mat. Granule surfaced mop applied SBS cap sheet reinforced with a polyester mat. Intec Flex PRF 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® Mop Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base (1 meter) Wide sheet reinforced with a polyester mat. NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 3 of 67 NOA 4- Test Product Product Dimensions Specification Description Ruberoid® Mop Smooth 1.5 39.37" ASTM D6164 Smooth surfaced mop applied SBS base (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® Mop Plus Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base or (1 meter) Wide ply sheet reinforced with a polyester mat. Ruberoid® Mop Plus Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® Mop Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced mop FR (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. Ruberoid® EnergyCap' Mop 39.37" ASTM D6164 Fire retardant granule surfaced mop Plus Granule FR (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT' EnergyCote7 Elastomeric Coating. Ruberoid® Mop Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced mop (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. Ruberoid® EnergyCapT' 30 39.37" ASTM D6163 Fire retardant granule surfaced mop Granule FR (1 meter) Wide applied SBS cap sheet reinforced with a fiberglass mat. Cap sheet is factory coated with TOPCOAT EnergyCoteT" Elastomeric Coating. GAFGLAS® Mineral -Surfaced 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Cap Sheet (1 meter) Wide reinforced with fiberglass mat. Tri-Ply® BUR Granule Cap 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Sheet (1 meter) wide reinforced with a fiberglass mat. GAFGLAS® EnergyCapT"' 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Mineral -Surfaced Cap Sheet (1 meter) Wide reinforced with fiberglass mat. Cap sheet is factory coated with TOPCOAT® EnergyCoteT" Elastomeric Coating. TOPCOAT® Membrane 1, 5 or 55 gallons ASTM D6083 Water based elastomeric coating. United Coatings" Roof Mate 1, 5 or 55 ASTM D6083 Water -based elastomeric coating TCM Coating Gallons TOPCOAT' 5 or 55 gallons ASTM D6083 Solvent based thermoplastic rubber sealant Surface Seal SB designed to protect and restore aged roof surfaces and to increase roof reflectivity. United CoatingsT" Surface Seal 5 or 55 Gallons ASTM. D6083 Solvent -based thermoplastic rubber SB Roof Coating sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. TOPCOAT MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer used to block asphalt bleed -through. United CoatingsT' Roof Mate 5 or 55 Gallons Proprietary Water based, low VOC primer designed to MB Plus Coating block asphalt bleed -through. NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 4 of 67 NaA � Membrane Type: APP/SBS Heat Weld Deck Type 1: Wood, Non -insulate Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type E(2): Anchor sheet is mechanically attached to roof deck. (Non -insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck (optional) Protection, VersaShield® Solo" Fire -Resistant Slip Sheet, DensDeck' Roof Board, SECUROCK® Gypsum -Fiber Roof Board or SECUROCK® Glass -Mat Roof Board. Base sheet: GAFGLAS® #80 Ultima" Base Sheet, GAFGLAS® Stratavene Nailable Venting Base Sheet, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth, Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25 Smooth mechanically fastened to deck as described below; Fastening GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® FlexPly' 6, Option #1: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS FlexPly"" 6, Option #2: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base sheets attached to deck with Drill-Tec'' #12 Fastener or Drill -Ted" #14 Fastener and Drill-Tec' 3" Steel Plate, Drill-Tec' AccuTrac® Flat Plate or Drill-Tec'"' AccuTrac® Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12.5" o.c. in the field of the sheet. y (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening GAFGLAS® FlexPly'" 6, GAFGLAS® 975 Base Sheet, Tri-Ply® #75 Base Sheet Option 93: or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in • two rows 9" o.c. in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure —52.5 psf. See General Limitation #7) Fastening GAFGLAS® 475 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base Option #4: sheets attached to deck with Drill-Tec' #12 Fastener or Drill-Tec' #14 Fastener and Drill -Tee'' 3" Steel Plate, Drill -Ted" AccuTrac® Flat Plate or Drill -Ted" AccuTrac® Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 53 of 67 I�CA 6 Fastening GAFGLAS® #80 Ultima"' Base Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop Option #5: Smooth base sheet attached to deck approved annular ring shank nails and 3" inverted Drill-Tec' 3" Steel Plate at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base Option #6: sheets attached to deck with Drill -Ted' 412 Fastener, Drill-Tec' # 14 Fastener or Drill-Tec' XHD Fastener and Drill-Tcc"' 3" Steel Plate, Drill -Ted' AccuTraco Flat Plate or Drill-Tec' AccuTrac® Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf. See General Limitation #9) Ply Sheet: (Optional except over Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth, Ruberoid® 20 Smooth, Ruberoid HW Smooth or Ruberoid® HW 25 Smooth) One or more plies GAFGLAS® Ply 4, Tri-Ply® Ply 4, or GAFGLAS® FlexPly'' 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or Ruberoid® Torch Smooth torch applied according to manufacturer's application instructions. Membrane: One ply of Ruberoid®Torch Smooth, Tri-Ply® APP Smooth Membrane, Ruberoid® Torch Granule, Tri-Ply® APP Granule Cap Sheet,, Ruberoid® EnergyCap' Torch Granule FR, Ruberoid® EnergyCap' Torch Plus Granule FR, or Ruberoid® Torch Plus Granule FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid HW Granule FR, Ruberoid® EnergyCap' HW Plus Granule FR Ruberoid® HW Granule, Ruberoid® HW Smooth and Ruberoid® HW 25 Smooth applied according to manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. . Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA.� I. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT® MB Plus or United Coatings'' Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT'S Membrane or United Coatings' Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMMISDECOUNTY ,...� � Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 54 of 67 rl 0A 3- WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® FlexPly' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'/4" DensDeck® Roof Board or Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psE 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 67 of 67 V nrvt-n ors I MA i q v v I!' aw v.. wrvv..y. . -1 - , ._..j Membrane: — One ply "RUBEROtDO Torch Smooth" or "Th-PlyOK' APP Smooth', torch applied or "RUBEROIDU Mop Smooth" or "RUBEROIDO Mop Smooth 1,5" or "RUBEROIDO Mop Plus Smooth", fully adhered with hot roofing asphalt. Membrane: — "RUBEROIDcRD Mop Plus Granule FR" or "RUBEROID@ EnergyCap'" Mop Plus Granule FR", fully adhered with hot roofing asphalt. 55. Deck: NC Incline: 1 �Pi Barrier Board (Optional): — One or more layers minimum 114-in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeckO Prime Roofboard" or "DensDeck DuraGuardr"I Roofboard" or minimum 114-in. thick United States Gypsum Co. "SECUROCKe Roof Board" (Type FRX-G) or "SECUROCK(0) Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — Polyisocyanurate or wood fiber or perlite or glass fiber, any thickness. mechanically fastened or fully adhered with hot roofing asphalt. Base Sheet: — One or more plies Type G2 "GAFGLASO #75 Base Sheet" or "Tri-Ply=_' #75 Base Sheet" or "GAFGLAS(D #80 Ulhma w Base Sheet" or "GAFGLASOW StratavenKe) Natlable Venting Base Sheet" or "GAFGLASO Stratavent0 Perforated Venting Base Sheet". mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet : — One or more plies "RUBEROIDU 20 Smooth" or "RUBEROIEW Mop Smooth" or "RUBEROIDU Mop Smooth 1.5" or "RUBEROIDO Mop Plus Smooth" fully adhered with hot roofing asphalt. Membrane: — "RUBEROIM HW Plus Granule FR" or "RUBEROID'k) HW Granule FR" or "RUBEROIDO EnergyCap"" HW Plus Granule FR" or "RUBEROIDO HW Plus Grande" or "RUBEROIM HW Granule", torch applied. 56, Deck: C-15/32 Incline: 1/2 Base Sheet: —Two or more plies Type G2 "GAF6kRSU #75 Sase Sheer 91 3nPly�- &75 Base Sheet' or "GAFGLASO #80 Ultima'" Base Sheet" or "GAFGLASO Stratavent0 Nailable Venting Base Sheet", mechanically fastened. Membrane: — "RUBEROIDO HW Plus Granule FR" or "RUBEROIDO HW Granule FR" or "RUBEROIDO EnergyCap"' HW Plus Granule FR" or "RUBEROID® HW Plus Granule" or IRUBEROID@ HW Granule", torch applied. 57. Deck: NC Incline: 1/2 Base Sheet: — "RUBEROIDO Mop Smooth" or "RUBEROID(R) Mop Smooth 1.5" or ' RUBEROID(R) Mop Plus Smooth", fully adhered with hot roofing asphalt or "RUBEROIDke' HW Smooth", torch applied Membrane: — "RUBEROID0 HW Plyys nu a Ryllp�tijl� Granule FR" or �u�or "UBEROID(DR HW Plus Granule-, torch annliar7 Incline: 1/2 h Insulate )*ocy 4ieAiv ickness of tapered minimum 1-1/2 in.. vrll14-3WI@6F i�?`tAN�d or ai ered with "LRF dA hesive M" or "TPO LRF Adhesive M Low Temp" or OMG Inc. "Olybond Fastening System", applied as a nominal 3/4-in. bead or "GAF 2-Part vpp, wt mctspa:�j. r4¢anumnn 4.pnp'id-TGF U.R17i . MIAMbDADE MIAMI-DADE COUNTY MM PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES RER 1I805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION ) Miami, Florida 33315-2599 NOTICE OF ACCEPTANCE (NOA) T n2nx 15-2590 F (78G) 3 onom9 ���r��rv.miamidade Gov/economy Boral Roofing LLC 7575 Irvine Center Drive #100 Irvine, California, USA 92816 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami, Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION Saxon 900-Slat Saxony Split Slate, Saxony 900- Shake & Saxony 900-Split Shake - Flat Profile Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 19-0814.02 and consists of pages I through 9. The submitted documentation was reviewed by Alex Tigers. l NOA No.: 21-0420.04 MIA raDADECOUNm Expiration Date: 05/02/24 Approval Date: 08/26/21 Page I of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Saxony 900-Slate & Split Slate, Saxony 900- Shake & Saxony 900- Split Shake as manufactured by Boral Rooting LLC, in Okeechobee, Florida as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Applicant Product Saxony 900-Slate & Split L =17" Specifications p TAS 112 Slate, Saxony 900- Shake Description Flat, Type 3a interlocking Class III, concrete tile W =13" & Saxony 900- Split H = 1.19" equipped with two nail holes. For direct deck or Shake Thickness:.70" _ battened nail -on, mortar or adhesive set applications. Trim Pieces L= varies TAS 112 W = varies Accessory trim, concrete roof pieces for use at hips, Varying thickness rakes, ridges and valley terminations. Manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description Manufacturer ICP Adhesives Polyset AH-160 Two component polyurethane (With Current NOA) foam adhesive. ICP Adhesives and Sealants, Inc. TILE BONDTm Roof Tile Adhesive Single component polyurethane foam roof tile adhesive. Touch `N Seal StormBond® 2 Two- Two component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive Touch `N Seal StormBond'a One One component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive "Tile Tite" Roof Tile Mortar Bonsai Roof Tile Mortar "Quikrete" Roof Tile Mortar, FL-15 Premixed, pre -bagged roof tile mortar. Premixed, pre -bagged roof tile mortar. Premixed, pre -bagged gray roof tile mortar. The Dow Chemical Company DAP Foam, Inc. DAP Foam, Inc. Bermuda Roof Co. Inc. Bonsai American The Quikrete Companies, Inc. MIAMI DADE COUNTY NOA No.: 21-0420.04 a' Expiration Date: 05/02/24 Approval Date: 08/26/21 Page 2 of 2.2 MANUFACTURING LOCATION Okeechobee, Florida 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Appendix III PA 102 & PA 102(A) Dec. 1991 7161-03 Appendix II PA 108 (Nail -On) Dec. 1991 Letter PA 108 (Nail -On) Aug. 1994 P0631-01 PA 108 (Mortar Set) July 1994 P0402 Withdrawal Resistance Testing of screw vs. Sept. 1993 smooth shank nails The Center for Applied 94-060A PA 101 (Mortar Set) March, 1994 Engineering, Inc. 94-084 PA 101 (Adhesive Set) May 1994 25-7094-2 PA 102 Oct. 1994 (4" Headlap, Nails, Direct Deck, New Construction) 25-7094-8 PA 102 (4" Headlap, Nails, Battens) Oct. 1994 25-7094-5 PA 102 (4" Headlap, Nails, Direct Deck, Oct. 1994 Recover/Reroof) 25-7183-6 PA 102 (2 Quik-Drive Screws, Direct Feb. 1995 Deck) 25-7183-5 PA 102 (2 Quik-Drive Screws, Battens) Feb. 1995 25-7214-1 PA 102 (1 Quik-Drive Screw, Direct Deck) March, 1995 25-7214-5 PA 102 (1 Quik-Drive Screw, Battens) March, 1995 Project No. 307025 PA 100 Oct. 1994 Test #MDC-77 Celotex Corporation Testing 520109-1 PA 101 Dec. 1998 Service 520111-4 PA 101 March 1999 520191-1 PA 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier October 2007 Calculations Moment of Gravity August 2007 Calculations 25-7094 February 1996 Calculations 25-7496 April 1996 Calculations 25-7584 December 1996 Calculations 25-7804b-8 December 1996 Calculations 25-7804-4 & 5 December 1996 Calculations 25-7848-6 December 1996 Calculations 25-7183 March 1995 Calculations Aerodynamic Multipliers April 1999 Calculations Two Paddy Adhesive Set System April 1999 American Test Lab of South TAS 112 RT1023.01-18 October 30, 2018 Florida Walker Engineering, Inc. Calculations Restoring Moment March 29, 2018 Aerodynamic Multipliers PRI Construction Material BORR-022-02-01 TAS 101 02/25/2019 r NOA No.: 21-0420.04 MIAMI DA COUNTY Expiration Date: 05/02/24 Approval Date: 08/26/21 Page 3 of 9 Technologies LLC BORR-022-02-02 TAS 101 02/25/2019 BORR-022-02-03 TAS 101 02/25/2019 BORR-022-02-04 TAS 101 02/28/2019 2002T0003.03 TAS 101 11/06/20 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 Mechanically attached tiles minimum 4/12 slope. 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.8 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Saxony 900-Slate & Split Slate, Saxony 900- Shake & Saxony 900- Split Shake and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight-W (Ibf) Length-1 (ft.) Width-w (ft) Saxony 900-Slate & Split Slate, Saxony 900- Shake & Saxon 900- Split Shake 10.9 1.42 1.08 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3) Dire lication Saxony 900-Slate & Split Slate, Saxony 900- Shake & Saxon 900- Split Shake 0.291 0.315 NOA No.: 21-0420.04 Expiration Date: 05/02/24 Approval Date: 08/26/21 Page 4 of 9 Table 3: Restoring Moments due to Gravity - Mg (ft.-Ibf) Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or Profile greater Saxony Battens Direct Battens qfteRt Battens Direct Battens Direct Battens Direct Battens Direct 900-Slate Deck Deck Deck Deck Deck Deck & Split N/A 7.70 --W/A7 7.63 4.74 7.51 4.65 7.71 4.53 7.17 4.40 6.97 Slate, Saxony 900- Shake & Saxony 900- Split Shake Table 4: Attachment Resistance Expressed as a Moment - Mr (ft: Ibf) for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min. 19132" plywood) Battens Saxony 900-Slate & Split Slate, Saxony 900- Shake & Saxony 900- Split Shake 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 50.3 65.5 48.3 1 Installation with a 4" the headlap and fasteners are located a min. of 21/2' from head of tile. NOA No.: 21-0420.04 Expiration Date: 05/02/24 Approval Date: 08/26/21 Page 5 of 9 Shake Split 9 10 11 12 Split :nment Resistance Expressed as a Moi for Two Paddy Adhesivez Set Systems Seal component) Minimum Attach Resistance --- -- • - n1anuudclurers component approval for installation requirements. Medium paddy weight of 8 grams per paddy of TILE BOND TM Roof Tile Adhesive Medium paddy weight of 16 grams per paddy of TILE BONDTM Roof Tile Adhesive Medium paddy weight of 8 grams per paddy of Polyset® AH-160 Medium paddy weight of 8 grams per paddy of Touch 'N Seal StormBond ® 2 Medium paddy weight of 18.7 grams between tile and underlayment, paddy weight of 10.5 grams on overlap of tile of Touch 'N Seal StormBond !Lone component) Saxony Shake Table 6: Attachment Resistance Expressed as a Mom for Single Paddy Adhesive Set Systems Tile Profile Tile Application weight of 45 grams of Polyset® AH-160 weight of 34 grams of Polyset® AH-160 weight of 24 grams of Polyset® AH-160 joveight of 18 grams of PolysetOO AH-160 weight of 45 grams of Touch 'N Seal StormBond ® 2 ly weight of 24 grams of Touch 'N Seal StnrmRnnr! Table 7: Attachment Resistance Expressed as a Moment - for Mortar Set Systems Tile Tile Profile Application Resistance Resistance ,.<= MIAMI DADE COUNTY '.'= NOA No.: 21-0420.04 Expiration Date: 05/02/24 Approval Date•. 08/26/21 Page 6 of 9 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 21-0420.04 MIAM6DADE COUNTY Expiration Date: 05/02/24 Approval Date: 08/26/21 Page 7 of 9 Nall Hales R PROFILE DRAWINGS 7-SIX-rly 0 Slate 1.5/32" Saxony 900 Split Slate NOA No.: 21-0420.04 Expiration Date: 05/02/24 Approval Date: 08/26/21 Page 8 of 9 32' ke END OF THIS ACCEPTANCE NOA No.: 21-0420.04 MIAMI•DADE COUNN Expiration Date: 05/02/24 Approval Date: 08/26/21 Page 9 of 9 Ct�INi� DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews 21-0602.14 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 21-1217.02 CMILAAUA F122.104 Expiration Date: 09/13/27 Approval Date: 09/08/22 Page 1 of 7 ROOFING COMPONENT APPROVAL Cate2ory: Roofing Sub-Cate2ory: Underlayment Material: SBS, APP PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick IR-Xe 65' x 3' Or 33.4' x ASTM D 1970 A fine granular/sand top surface self -adhering, APP Manufacturing 31 polymer modified, fiberglass reinforced, bituminous sheet Location #1 & 42 60 mils thick material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. Polystick TU Max 65'8" x 3'3-3/8" TAS 103 A rubberized asphalt self -adhering, polyester reinforced Manufacturing 60 mils thick waterproofing membrane. Designed as a a roof tile Location # 1 & #2 underlayment. Polystick TU P 32'10" x 3'3-3/8" TAS 103 A rubberized asphalt waterproofing membrane, glass - Manufacturing 130 mils thick fiber/polyester reinforced, with a granular surface Location #2 designed for use as a tile roof underlayment. Polystick TU Plus 65' x 3'3 3/8" TAS 103 A rubberized asphalt self -adhering, glass-fiber/polyester (Surface Printing) 80 mils thick reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof tile underlayment. Location # 1 & #2 Polystick NITS 6518" x 313-3/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick NITS Plus 6518" x 313-3/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Elastoflex S6 G 32'10" x 3'3 %" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location #2 use in roof tile underlayment systems. MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL CMILAMEDADMECNOA No.: 21-1217.02 • 0 0 Expiration Date: 09/13/27 Approval Date: 09/08/22 Page 2 of 7 Test Agency Trinity I ERD NEMO I etc. LLC LABELING: EVIDENCE SUBMITTED Test Identifier Test Name/Report P40390.10.12 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14-R1 PLYG-SC7550.03.15 PLYG-SC 10130.06.16-3 PLYG- SC 1013 0.06.16-1 PLYG-SC10130.09.16 PLYG-SC 1303 5.08.17 PLYG-SC 15 85 5.05.20-A 4j-PLYG-2I-SSUDL-03.A ASTM D 1970 ASTM D6164 TAS 103, TAS 110 & ASTM D1623 ASTM D1623 TAS 103 & TAS 110 ASTM D 1970 & TAS 110 TAS 103 & ASTM D4798 TAS 103 & TAS 110 ASTM D1970 & TAS 110 ASTM D1623 TAS 103 & ASTM D4798 TAS 103 & TAS 110 ASTM D1970 Date 10/03/12 07/02/13 05/12/14 10/03/14 10/07/14 10/17/14 03/24/15 06/27/16 06/27/16 09/22/16 10/32/17 05/29/20 10/29/21 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 21-1217.02 MIAMbOADECOUNTY Expiration Date: 09/13/27 Approval Date: 09/08/22 Page 3 of 7 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Elastoflex S6 G, hot asphalt applied Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 21-1217.02 MIAhu•nADEcouNn Expiration Date: 09/13/27 ' " • ' Approval Date: 09/08/22 Page 4 of 7 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick TU Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, adhered roof tile using ICP Adhesive Polyset RTA-1, mechanically fastened roof tile systems and quarry slate roof assemblies. Polystick MTS may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, mechanically fastened roof tile systems and quarry slate roof assemblies. Polystick MTS Plus, may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, mechanically fastened roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in asphaltic shingles, wood shakes and shingles, mechanically fastened roof tile systems and quarry slate roof assemblies. Polystick IR-Xe may be used in asphaltic shingles, wood shakes and shingles, and quarry slate roof assemblies. Polystick TU Max may be used in non-structural metal roofing, adhered roof tile using ICP Adhesive Polyset RTA-1 or ICP Adhesives Polyset AH-160, and mechanically fastened roof tile systems. Elastoflex S6 G may be used in adhered roof tile using ICP Adhesive Polyset RTA-1 or ICP Adhesives Polyset AH-160, and mechanically fastened roof tile systems. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. NOA No.: 21-1217.02 MIAMI•DADE COUNTY Expiration Date: 09/13/27 Approval Date: 09/08/22 Page 5 of 7 Expo ure Limitations (Days) Polystick MTS Polystick IR-Xe Elastoflex S6 G Polystick TU Plus Polystick TU P Polystick TU Max Polystick MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 Hazelton, PA N/A 90 N/A 180 N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 8. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (E3) Profile MTS S6 G Polystick TU P TU Max MTS Plus MTS Plus with TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6:12 Tile without battens The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall be utilized during loading and installation of tiles. 9. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. 0 a 0 U) N to 10. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. NOA No.: 21-1217.02 Expiration Date: 09/13/27 Approval Date: 09/08/22 Page 6 of 7 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick NITS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #8 and #9. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of TV12" or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 21-1217.02 Expiration Date: 09/13/27 Approval Date: 09/08/22 Page 7 of 7 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.miamidade.eov/economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polysee AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 20-1124.07 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 22-0411.02 MIAMI•DAD' COUNTY Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polyset° AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using Polyset® AH-1 60. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications Polyset°AH-160 N/A TAS 101 Two component polyurethane foam adhesive ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPack" N/A Dispensing Equipment 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of Polyset° AH-160 roof the adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density @ 73°F ASTM D1622 2.1 lbs./ft.3 Compressive Strength ASTM D1621 18 PSI Parallel to rise 14 PSI Perpendicular to rise Tensile Strength ASTM D1623 29 PSI Parallel to rise Water Absorption ASTM D2842 0% Moisture Vapor Transmission ASTM E96 2.3 Perms Dimensional Stability ASTM D2126 +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks Closed Cell Content ASTM D6226 94% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 22-0411.02 Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 2 of 11 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 O 1-6739-062b[ 1] ASTM E 84 O 1 /16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 NEMO ETC, LLC 4p-ICP-20-SSLAP-OI.B Physical Properties 11/11/20 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polyset° AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polyset° AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 22-0411.02 MIAMI•DADECOUNTY Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 3 of 11 INSTALLATION: 1. Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of Polyset° AH-160. 2. Polyset° AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof the assembly's adhesive attachment with the use of Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. Polyset° AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. Polyset° AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPacko 30 & 100 dispensing equipment only. 7. Polyset® AH-160 shall not be exposed permanently to sunlight. S. Tiles must be adhered in freshly applied adhesive. Tile must be set within I to 2 minutes after Polyset® AH-160 has been dispensed. 9. Polyset° AH-160 placement and minimum patty weight shall be in accordance with the'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 22-0411.02 MIAMI•DADE COUNTY Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece j 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. MIAMIOADE COUNTY ...S r � BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 22-0411.02 Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 5 of 11 ADHESIVE PLACEMENT DETAIL ## 1 Nail through plastic cement Paddy (Beneath Tile) (when required) Underlayment K R\ 10 In Battens optional o Eave Course o 0 10 in. ��2 n Fascia Eave Closure Nail through plastic cement (when required) Paddy (Beneath Tile) Underlayment r 10 in. x 2inin.wide y. Battens optional t 0 in. 21n. Eave Closure Eave Course Fascia Nail through plastic ce e (when required) Paddy (Beneath Tile) Underlayment o 10in.x 2 in. wide Battens o optional 0 3 F/ Eave Course Fascia Weephole 101n. 2 in. Eave closure Drip edge MIAMI•DADE COUNTY Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. NOA No.: 22-0411.02 Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 6 of 11 ADHESIVE PLACEMENT DETAIL ## 2 Nail through plastic cement Paddy (Beneath Tile) (when required) Ulnderlayment v3 R\ 71n.�►�In Battens optional ° Eave Course ° 10 in. �in Fascia Eave Closure Nail through plastic cement (when required) Paddy (Beneath Tile) Underlayment 7 in. 2 in. Battens optional 10 in. 21n. Eave Closure Eave Course Fascia Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x I" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the the being set. Insure approximately 17 (109.7 cm 2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12(77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 min) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 22-0411.02 Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 7 of 11 ADHESIVE PLACEMENT DETAIL ## 2 (CONTINUED) Nail through plastic ce (when required) Paddy (Beneath Tile) UI nderlayment 7in.. 2i 2 m. Battens optional Eave Course Fascia Weephole 10in. in. Eave closure Drip edge APPROVED High Profile / Single Pan Tile Starting at the eave course, apply a minimum 2" (50.8 rum) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm 2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1 " (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Continue in same manner. Insure approximately 17" (109.7 cmz) - 19 (122.6 cmz) square inch adhesive contact with the underside of the tile. NOA No.: 22-0411.02 Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 8 of l 1 ADHESIVE PLACEMENT DETAIL # 3 Nail throughplasticcement Paddy (between tiles) {when required; I i eattensoptional Y o y Padd iwtdertile) car single paddy on top oiithe .f ` axain. i 'Af sinngglepad� a underti ` s* SraglepaddyY'.+ on underlayment,- Itt4in 10 iri:�- - Fascia caveclosuxe Flat/Low Profile Tile Nail through plastic Cement Single paddy under the iwhen required) paddy (between tiles i Battens Paddy tunder tile) optional 'i; - t, single paddy ' on top of the •tex4in. 2zain.` Singglepaddy underiaymentr .. 14M k� 2in. Eave Closure Eave Course Fascia Medium Profile Tile MIAMI•DADE COUNTY 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in2 (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1 n (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in (51.6-58.1 cm2) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 22-0411.02 Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nail through plastic Ce Single paddy under tile (when requiredl Raddy_ (between tiles) Battens opdonal r Paddy iunder tile: V single addy'--- on underiayment: } t t14 x 4 in. Single 2xei�;j t- paddyy on,, top of ule ' f EaveCome—: ii Easda Weephole !oin.'' rein. Eave \Dripedgeosure f High Profile Tile MIAMI•DADE COUNTY ...l r Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 1/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the the at the head of the tile. Continue in same manner. NOA No.: 22-0411.02 Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 10 of 11 V. ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications in contact with the pan tile. A (when required) 2) Turn covers upside down. Place adhesive In to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area. -. o IUnderlayment r Sheathing Eave closure (motar shown) Fascia Board Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm') — 70 (451.6 cm') square inch adhesive contact with the underside of the pan tile. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm') - 25 (161.3 cm') square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 22-0411.02 MIAMI•DADECOUNTY Expiration Date: 05/10/27 Approval Date: 05/05/22 Page 11 of 11