Loading...
RF-05-22-1166Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address 574 NE 95TH ST, Miami Shores, FL 33138 Permit NO.: RF-05-22-1166 Permit Type: Roof Work C/ossii ication: Tile Permit Status: Approved Issue Date: 05f' b ~ Expiration: 11/28/2022 Parcel Number 1132060140790 W Contacts Maureen Lord Owner OBENOUR ROOFING SHEET METAL & Contra ctor 574 NE 95 ST SUPPLY CO. INC JAMES OBENOUR 9822 NE 2 AVE SUITE 9, MIAMI SHORES, FL 33138 Business: 3057572612 OBENOURROOFING@AOL.COM Description: RE ROOF TILE- ROOF WITH BORAL SAXONY SLATE 49 �I Valuation: $ 36,475.00 k Inspection Requests: "STERLING" ABMESIVE SET Total Sq Feet: 2,517.00 Fees Amount Application Fee - Other $50.00 CCF $22.20 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $7.40 Roofing Fee $250.00 Technology Fee $7.50 Total: $344.60 MMMEM Payments Date Paid Amt Paid Total Fees $344.60 Check# 11325 05/09/2022 $50.00 Check If 11333 05/26/2022 $294.60 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, 1,quthorize theogve named contractor to do the work stated. Authorized Signature: Owner / Contractor / Agent Date May 26, 2022 Page 2 of 2 Miami Shores Village RECEIVED Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC gROOFING F-IPLUMBING ❑ MECHANICAL JOB ADDRESS: MAY o 6 i0??. BY: F 1B�C 2r0 Master Permit No. R _OJ ZZ7 Sub Permit No. 'A )�-- I to l ❑ REVISION ❑ EXTENSION ❑RENEWAL E]PUBLICWORKS ❑CHANGE OF CONTRACTOR I% ❑ CANCELLATION ❑ SHOP DRAWINGS Folio/Parcel#: 3;0. - ON- 07 /41 Is the Building Historically Designated: Yes NO. Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): MAdR 4-6A) dVeb Phone#:34'S"35-04/ Add S% City: i6/ir7Yyl SIu X, S State: 44 Tenant/Lessee Name: Email CONTRACTOR: Company Name: 0t54C"041/C- X'c'E/5/Phone#: f`'�"-%d�% �/.l Address:/ %S'u Alt- a? ff I/ City: !T�//�''rr S%°QP S State: f j zip: 33/ 3 a' Qualifier Name: J�'-/°'I e 1 D G%j2-gyp,/✓ Phone#: .3&S-7S-7 -'dG/L State Certification or Registration #: eeC_ O! `1,30 G Certificate of Competency #: C- x G 5/d-Tl DESIGNER: Architect/Engineer: State: Zip: Value of Work for this Permit: $ 3L•r 4( 7U . �- Square/Linear Footage of Work: _)L 5 / 7 Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace ❑ Demolition Description of Work: � Wc.. F ///6 ' c t u/i Tr1 f3�f ✓f ( .r/f x JYc� �L /1-2�E C 0 4AI,A-St//t C-k/ Specify color of color thru tile: s i <_ 2.2-r //,c Submittal Fee Scanning Fee $ Technology Fee Structural Reviews $ Permit Fee $ Radon Fee $ Training/Education Fee $ CCF$ CO/Cc$ DBPR $ Notary Double Fee $ Bond$ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City State ME Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs ev (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not bq4pproved and a teinsp4donfee will be charged. OWNER or AGENT T e fo going instrument was acknowledged before me this day of921 20 .Z by M nGrb Pt- t-o X �- who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: CONTRACTOR The foregoing instrument was acknowledged before me this lday of 207_-, • by M es b ID � who is personally known to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: as Zoning (Revised02/24/2014) Structural Review Clerk Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.aov OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2"d Ave Miami Shores, FI 33138 Re: Owner's Name: R4L� R(,PV )ot.b Property Address: SZ-/ We �� Si Roofing Permit Number: S _ 5 za z_2� Dear Building Official: 1 &.4 dLo,C A certify that I am not required to retrofit the roof t all connections of my building because: 7Th�i The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Pleakattach proof of ad valorem taxation. ❑ The building wa c nstructed in compliance with the provisions of the Florida Building Code (FBC r with the sions of 1994 edition of the South Florida Building Code(1994BC) Signature Print Name State of Florida, Miami Dade County The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed befor` 20 , .; ; ,MSIOk HH0 EXPIRSray74,2025 ' $ •'Bn^dad Tha P' ,�y Doc Ur.�eudten Notary Public, State of Florida at Large` • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. For Forms and Applications click here: http://bldg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia miShoresVillage Rev01 142021 Owner affidavit of exemption Page 1 of 1 OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-014-0790 Property Address: 574 NE 95 ST Miami Shores, FL 33138-2732 Owner MAUREEN E LORD Mailing Address 574 NE 95 ST MIAMI SHORES, FL 33138-2732 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SO Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY:1 UNIT Beds I Baths I Half 2/2/0 Floors 1 Living Units 1 Actual Area 2,005 Sq.Ft Living Area 1,729 Sq.Ft Adjusted Area 1,863 Sq.Ft Lot Size 12,900 Sq.Ft Year Built 1940 Assessment Information Year 2021 2020 2019 Land Value $413,936 $413,936 $386,677 Building Value $129,665 $129,665 $129,665 XF Value $1,782 $1,792 $1,802 Market Value $545,383 $545,393 $518,744 Assessed Value $171,097 $168,735 $164,942 Benefits Information Benefit Type 2021 2020 2019 Save Our Homes Cap Assessment Reduction $374,286 $376,658 $353,202 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 2 PB 10-37 LOTS 3 & 4 BLK 55 LOT SIZE 100.000 X 129 OR 14110-981 0589 1 Generated On : 5/9/2022 Taxable Value Information 2021 2020 2019 County Exemption Value $50,000 $50,0001 $50,000 Taxable Value 1 $121,0971 $118,7351 $114,942 School Board Exemption Value $26.000 $25,000 $25,000 Taxable Value 1 $146,097 $143,7351 $139,942 city Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $121,0971 $118.7351 $114,942 Regional Exemption Value $50,0001 $50,000 $50,000 Taxable Value $721,097 $118,735 $114,942 Sales Information Previous Sale Price OR Book -Page Qualification Description 05/01/1989 $113,000 14110-0981 Sales which are qualified 06/01/1978 $57,000 10078-0336 Sales which are qualified 10101/1977 $55,500 09849-0273 Sales which are qualified 10/01/1973 $52,000 00000-00000 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This websim may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:// v .miamidade.gov/info/disclaimer.asp Version: Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.ctov SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The ow s i 'tial in the designated space indicates that the item has been explained. 1. Aesthetics -Workmanship: the workmanship provisions of Section R4402 are f r t e pur of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appeara ce, that are not part of a zoning code, should be addressed as part of the aerleE Xt between the owner and the contractor. 2. mailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The rogf Neck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation b e neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common ro fs, the roofing contractor and/or owner should notify the occupants of adj ent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the r dec . an be viewed from below. The owner may wish to maintain the architectural a earance, therefore, roofing nail penetration of the underside of the decking may not be a ptable. This provides the option of maintaining the appearance. 0 L-PC nding water: The current roof system and/or deck of the building may not d and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. Rev01 142021 Owners roofing consideration Page 1 of 2 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.qov !rflow scuppers (wall outlets): It is required that rainwater flows off so that verloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Septlons R4402, R4403 and R4413. Ventilation: Most roof structures should have some ability to vent natural ai o throu h the interior of the structure assembly (the building itself). The existing amount of atc ventilation shall not be reduced. It may be beneficial to consider additional vgting which n result in extending the service life of�oe roof, — 5'— �oz.7i Agent's Signature Date ature 16126'->-�- Date For Forms and Applications click here: http://bldg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia miShoresVillage RevOI 142021 Owners roofing consideration Page 2 of 2 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.aov SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES— REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The ow s i 'tial in the designated space indicates that the item has been explained. 1. Aesthetics -Workmanship: the workmanship provisions of Section R4402 are f r t e pur of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural aopearance, that are not part of a zoning code, should be addressed as part of the between the owner and the contractor. 2. nailing wood decks: When replacing roofing, the existing wood roof deck av have to be renailed in accordance with the current provisions of Section R4403. (The is usually concealed prior to removing the existing roof system). ;. Common roofs: Common roofs are those which have no visible delineation be neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adj ent units of roofing to be performed. 4, Exposed Ceiling: Exposed, open beam ceilings are where the underside of the r dec an be viewed from below. The owner may wish to maintain the architectural a earance; therefore, roofing nail penetration of the underside of the decking may not be a&ptable. This provides the option of maintaining the appearance. 5. Ponding water: The current roof system and/or deck of the building may not d and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. ReV01 142021 Owners roofing consideration Page 1 of 2 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.ciov scuppers (wall outlets): It is required that rainwater flows off so that ided from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Segtlons R4402, R4403 and R4413. Ventilation: Most roof structures should have some ability to vent natural ai o throu h the interior of the structure assembly (the building itself). The existing amount of ati�jc ventilation shall not be reduced. It maybe beneficial to consider additional v�ting which n result in extending the service life ofAe roof Signature Date ntractorSignature Date For Forms and Applications click here: http://bidg. miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia miShoresVillage ReV01 142021 Owners roofing consideration Page 2 of 2 Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County Section A (General Information) RECEIVED Master Permit Number: Contractor's Name: Process Number: BY Job Address: 3 Z'/ /_ Y�_ S/ ❑ Low Slope ROOF CATEGORY ❑ Mechanically Fastened Tile Q Mortar/Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/ Shingles ❑ Wood Shingles / Shakes ROOF TYPE ❑ New Roof ❑ Repair ❑ Maintenance EJ Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (ft') Steep Sloped Roof Area (ft2) Total (ft2) /JY / 7 of 5-/ -/ Are there gas vents on the roof? O Yes (7 N�o If Yes what type? 0 Natural o LPX Is there an existing roof top Solar System? O Yes O'No If yes will it be reinstalled? 0 Yes 0 No Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Z/ !2 I CITY COPY,z I 3 19 V .tY� Miami Shores Village Building Department Zoning Dept. Date Building Dept. Date Subject to compli a with all Federal, State and County rules nd regulations. /fr Permit# Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County Section D (Steep Sloped Roof System) Roof System Manufacturer: Product Control Number: LA/ Aor A'I✓i 2J- 6 Minimum Design Wind Pressures, From Applicable RAS 127 Table or Calculations: Zone1: /a: G' S Zone 2e: /a�G 5 Zone2n: ZG.y Zone 2r: 24 Zone 3e: 94• V Zone 3r: 31• Z Slope Range: e52:12 to <_ 4:12 Roof Slope: .: 12 Ridge Ventilation? N/ A Roof Shape: OAII Hip Roof 0>4:12to:56:12 0>6:12to!512:12 (Diable Roof or Partial Gable/Hip Roof Deck Type: I '✓_J `J1.4'x Underlayment Type: *3 m /i 2,2 4, Mean Roof Height: Insulation: 1 W4 Fire Barrier: l_ 4A Fastener Type & Spacing: — .. a o _Aw_S u Cap Sheet Type: 1 /2,1� 9144 ti % v /4 •4 X &Ze'16n441.d 'L— IZ"d .G Cap Sheet Attachment: SrZr1.-Wve, Roof Covering: /G( fiTcry %n'� S%i't c Drip Edge Type & Size: 21 9A yWI 3F Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County Section E (Tile Calculations) For Moment based tile systems, choose Method 1. Compare the values for Mrwith the values from Mf. If the Mf values are greater than or equal to the Mr values for each area of the roof, then the tile attachment method is acceptable. Method 1* " Moment Based Tile Calculations per RAS 127" Enter positive uplift pressures when using this table ( Zone 1: 'N x ), .3/6 = 03.3/) — Mg: 7•t_2 = Mn it'L f Product Approval Mf: b3 (zone 2e: --N x A ,31L = 73.31 ) _ Mg: 7.6 Z = Mr2e N :L f Product Approval Mf: & 3 ( Zone 2n: —/uS x A j/4' = 3r%a2 )—Mg: 9.6 z- = Mr2n 210. Y Product Approval Mf: tj ( Zone 2r:—/aP xA 31a�= 34-02-)—Mg: 7.42 =Mr2r u•V Product Approval Mf: g3 (Zone3e: 9 /uxA '311i = 3yo2-)—Mg: 71 r=Mrae t&•y Product Approval Mf: (Zone3r:xA'3ri'= lo.0-)— mg: %41" =Mr3, 32.7 Product Approval Mf: B3 Tile attachment method: Alternate Tile attachment method: For Uplift Based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values for each area of the roof, then the tile attachment method is acceptable. Method 3* "Uplift Based Tile Calculations per RAS 127" (Zone 1: x L = x W = ) — (w) x cos B ) = Fr2 Product Approval F': (Zone 2e: —x L = x W = ) — (w ) x cos 9 ) = Fr2e Product Approval F': (Zone 2n: —x L = x W = ) — (w) x cos 8 ) = Fr2� Product Approval F': (Zone 2r: x L = x W = ) — (w) x cos B ) = Fr2r Product Approval F: (Zone 3e: x L = x W = ) — (w) x cos B ) = Fr3e Product Approval F': (Zone 3r: x L = x W = ) —(w) x cos B ) = Fr3 Product Approval F': *Method 2 "Simplified Tile Calculations" only applicable in Broward County. Where to obtain N rmatlon Description Symbol Where to Find Design Pressure Zones 1, 2e, 2n, 2r,3e, 3r From the applicable Table in RAS-127 or be an engineering analysis prepared by a PE based upon ASCE 7 Mean Roof Height H Job Site Roof Sloe B Job Site Aerodynamic Multiplier A Product Approval / Notice of Acceptance Restoring Moment due to Gravity M Product Approval / Notice of Acceptance Attachment Resistance Mf Product Approval / Notice of Acceptance Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval / Notice of Acceptance Required Uplift Resistance F, Calculated Average Tile Weight w Product Approval / Notice of Acceptance rile Dimensions L=Length W= Width Product Approval / Notice of Acceptance All calculations must be submitted to the Building Official at the time of permit application. Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component Product Approval 5. Municipal Permit Application 6. Owner's Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing / Calculation Documentation MIMI I. MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DMSION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.mismidade.eov/economy Beral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 21-0420.03 and consists of pages 1 through 10. The submitted documentation was reviewed by Alex Tigera. NOA No.: 22-0201.08 M AMMADE COUNTY Expiration Date: 04/26/27 Approval Date: 04/21/22 Page 1 of 10 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Cateeorv: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Saxony 900-Slate Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-5/32" batten, mortar set or adhesive set applications. Saxony 900 - Split Shake Saxony 900-Shake Trim Pieces MIAMFDADECOUNTY ,.... 1 Length =17" Width= 13" thickness = 1-9/32" Length = 17" Width= 13" thickness = 1-9/32" Length: varies Width: varies varying thickness TAS 112 Flat profile, interlocking, high-pressure extruded concrete roof tile with two nail holes. For direct deck, batten, mortar set or adhesive set applications. Top surface produced with 4 different configurations: 1. Complete rile brushed 2. Right half brushed (shown in drawing) 3. Left half brushed 4. No brush TAS 112 Flat profile, interlocking, high-pressure extruded concrete roof tile with two nail holes. For direct deck, batten, mortar set or adhesive set applications. TAS-112 Accessory trim, boosted Barcelona, concrete roof pieces for use at hips, ridges and rakes. STERLING 1 FMCS5759 NOA No.: 22-0201.08 Expiration Date: 04/26/27 Approval Date: 04/21/22 Page 2 of 10 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Descrintion ICP Adhesives Polysee AH-160 TILE BONDTM Roof Tile Adhesive "Tile Tite" Roof Tile Mortar Touch `N Seal StormBondo 2 Two - Component Polyurethane Roof Tile Adhesive Two component polyurethane foam adhesive. Single component polyurethane foam roof file adhesive. Premixed, pre -bagged roof tile mortar. Two component polyurethane foam adhesive. Touch `N Seal StormBone One One component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL 2.3 EVIDENCE SUBMITTED: Test Agency Test Identifier The Center for Applied 94-084 Engineering, Inc. 94-060A Redland Technologies 25-7183-6 25-7183-5 25-7214-1 25-7214-5 Project No. 307025 Test #MDC-77 7161-03 Appendix II & III Letter Dated Aug. 1, 1994 P0631-01 P0402 Manufacturer (With Current NOA) 1CP Adhesives and Sealants, Inc. DuPont de Nemours, Inc. Bermuda Roof Co. Inc. DAP Foam, Inc. DAP Foam, Inc. Test Name/Report Date Static Uplift Testing May 1994 TAS 101 (Mortar Set) Static Uplift Testing March, 1994 TAS 101 (Adhesive Set) Static Uplift Testing TAS 102 Feb. 1995 (2 Quik-Drive Screws, Direct Deck) Static Uplift Testing TAS 102 Feb. 1995 (2 Quik-Drive Screws, Battens) Static Uplift Testing TAS 102 March, 1995 (1 Quik-Drive Screw, Direct Deck) Static Uplift Testing TAS 102 March, 1995 (1 Quik-Drive Screw, Battens) Wind Driven Rain Oct. 1994 TAS 100 Wind Tunnel Testing Dec. 1991 TAS 108 (Nail -On) Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails NOA No.: 22-0201.08 Expiration Date: 04/26/27 Approval Date: 04/21/22 Page 3 of 10 Atlanta Testing & R1.894/R2.894/R3.894 Physical Properties Aug. 1994 Engineering, Inc. TAS 112 Celotex Corporation 520109-1 Static Uplift Testing Dec.1998 Testing Service 520111-4 TAS 101 520191-1 Static Uplift Testing March 1999 TAS 101 Walker Engineering, Evaluation Calculations 25-7094 February 1996 Inc. Evaluation Calculations 25-7496 April 1996 Evaluation Calculations 25-7584/25-7804b-8/25-7804-4 & 5 December 1996 25-7848-6 Evaluation Calculations 25-7183 March 1995 Evaluation Calculations Aerodynamic Multipliers 09/01/16 Calculations Two Patty Adhesive Set System April 1999 Evaluation Calculations Restoring Moments Due to Gravity 09/01/16 American Test Lab of RT0617.04-16 TAS 112 06/29/16 South Florida RT0209.01-22 TAS 112 02/01/22 RT0209.04-22 TAS 112 02/17/22 PRI Construction COPO-002-02-12 TAS 101 10/12/2016 Material Technologies COPO-002-02-06 TAS 101 10/12/2016 COPO-002-02-05 TAS 101 10/12/2016 BORR-022-02-01 TAS 101 02/25/2019 BORR-022-02-02 TAS 101 02/25/2019 BORR-022-02-03 TAS 101 02/25/2019 BORR-022-02-04 TAS 101 02/28/2019 2002T0003.03 TAS 101 11/06/20 MEMO ETC, LLC 4c-DPBS-20-LSOTM- TAS 101 12/17/20 0I.C.R1 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.: 22-0201.08 Expiration Date: 04/26/27 Approval Date: 04/21/22 Page 4 of 10 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Saxony 900 Slate, Shake & Split Shake 10.9 1.417 1.08 Table 2: Aerodynamic Multipliers -2, (ft') Tile Profile 2. (ft3) 2. (ft3) Batten Application Direct Deck Application Saxony 900 0.291 0.315 Slate, Shake & Split Shake Table 3: Restoring Moments due to Gravity - Mg (ft-lbf) Tile Profile 2":12" 3":12" 4":12" 5":12" 61.:12" 7":12" or greater Saxony 900 Slate &, Shake & Direct Deck Direct Deck I Battens I Direct I Deck Battens I Direct I Deck Battens Direct Deck Battens Direct Deck Split Shake 7.70 1 7.62 1 6.61 1 7.50 1 6.48 1 7.34 6.31 7.16 6.13 1 6.95 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Profile Fastener Type Direct Deck Direct Deck Battens (min 15/32" plywood) (min. 19/32" plywood) Saxony 900 2-10d Ring Shank Nails 30.9 38.1 17.2 Slate, Shake & 1-10d Smooth or Screw 7.3 9.8 4.9 Split Shake Shank Nail 2-10d Smooth or Screw 14.0 18.8 7.4 Shank Nails 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nail Field Clip) 1-10d Smooth or Screw 19.0 19.0 22.1 Shank Nail Eave Clip) 2-10d Smooth or Screw 35.5 35.5 34.8 Shank Nails Field Clip) 2-10d Smooth or Screw 31.9 31.9 32.2 Shank Nails Eave Clip) NOA No.: 22-0201.08 MIAMMADECOUNTY Expiration Date: 04/26/27 f Approval Date: 04/21/22 Page 5 of 10 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive' Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate &, Shake & Split Shake TILE BONDTM Roof Tile Adhesive 632 TILE BOND"" Roof Tile Adhesive 653 ICP Adhesives Pol set® AH-160 31.34 Touch 'N Seal StormBonde2 595 Touch 'N Seal StormBond" (one component) 1055 1 See foam adhesive manufacturer's component approval for installation requirements. 2 Medium paddy weight of 8 grams per paddy of TILE BOND"" Roof Tile Adhesive 3 Medium paddy weight of 16 grams per paddy of TILE BOND"" Roof Tile Adhesive 4 Medium paddy weight of 8 grams per paddy of Polyset® AH-160 5 Medium paddy weight of 8 grams per paddy of Touch 'N Seal StormBond 412 6 Medium paddy weight of 18.7 grams between tile and underlayment, paddy weight of 10.5 grams on overlap of tile of Touch'N Seal StormBond ® one component) Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Saxony 900 Slate &, Shake & Split Shake ICP Adhesives Polyset@ AH-160 1197 ICP Adhesives Pol set® AH-160 1155 ICP Adhesives Pol set® AH-160 839 ICP Adhesives Pol set® AH-160 6070 Touch 'N Seal StormBond®2 93" Touch 'N Seal StormBond®2 62t2 7 Large paddy weight of 45 grams of PolysetO AH-160 8 Medium paddy weight of 34 grams of Polyset® AH-160 9 Medium paddy weight of 24 grams of Polyset® AH-160 10 Medium paddy weight of 18 grams of Polyset® AH-160 11 Large paddy weight of 45 grams of Touch 'N Seal StormBond ® 2 12 Medium paddy weight of 24 grams of Touch 'N Seal StormBond e 2 Table T: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Saxony 900 Slate &, Shake & Split Mortar Sei13 43.9 Shake 13 Bermuda Roof Co. Inc. Tile -rite Roof Tile Mortar. NOA No.: 22-0201.08 MIAMMADE COUNTY Expiration Date: 04/26/27 Approval Date: 04/21/22 Page 6 of 10 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 22-0201.08 MIAM E ADE COUNTY Expiration Date: 04/26/27 FS—UNI M Approval Date: 04/21/22 Page 7 of 10 NAIL HOLES PROFILE DRAWINGS UNDERLOCK SAXONV 900 - SLATF. 5/32" (Slate) COVERLOCK NOA No.: 22-0201.08 MIAMMADE COUNTY Expiration Date: 04/26/27 r"Mueymm Approval Date: 04/21/22 Page 8 of 10 NAIL HOLES Note: t. 2. 1 4. PROFILE DRAWINGS Available Top Surface Finishes Complete tile brushed Right half brushed (shown in drawing) Left half brushed No brush SAXONY 900 - SPLIT SHAKE MIAMIDADE COUNTY ..., 1-9/32" (Shake) NOA No.: 22-0201.08 Expiration Date: 04/26/27 Approval Date: 04/21/22 Page 9 of 10 NAIL HOLES WE PROFILE DRAWINGS SAXONY 900- SHAD END OF THIS ACCEPTANCE 1-9/32" (Shake) NOA No.: 22-0201.08 MIAMFDAUECOUNTY Expiration Date: 04/26/27 Approval Date: 04/21/22 Page 10 of 10 MIMUMADE MIAMI-DADE COUNTY ® PRODUCT CONTROL DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/economv Polyglass USA Inc. I I I I W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable Hiles and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.17-0614.22 and consists of pages 1 through 7. The submitted documentation was reviewed by Jorge L. Acebo.. -� V" MIAMMADE COUNTY RI NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 1 of ROOFING COMPONENT APPROVAL Cateeorv: Roofing Sub-Cateeorv: underlayment Material: SBS, APP PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick IR-Xe 65' x 3' Or 33.4' x ASTM D 1970 A fine granular/sand top surface self -adhering, APP Manufacturing 3' polymer modified, fiberglass reinforced, bituminous sheet Location #1 & #2 material for use as an underlayment in sloped roof 60 mils thick assemblies. Designed as an ice & rain shield. Polystick TU Max 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self -adhering, polyester reinforced Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile Location #1 & #2 underlayment. Polystick TU P 32'10" x 3'3 3/s" TAS 103 and A rubberized asphalt waterproofing membrane, glass - Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced, with a granular surface Location #2 designed for use as a tile roof underlayment. Polystick TU Plus 65' x 3'3 ;/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester (Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof tile underlayment. Location 41 & 42 Polystick NITS 65'8" x 313/s" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick NITS Plus 65'8" x 3'3 '/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Elastollex S6 G 32'10" x 31-3/s" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location #2 use in roof tile underlayment systems. MANUFACTURING PLANTS: 1. Hazelto% PA 2. Winter Haven, FL NOA No.: 21-0602.14 MIAMMADE COUNTY Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 2 of 7 Test Agency Trinity I ERD LABELING: EVIDENCE SUBMITTED Test Identifier Test Name/Reuort P37300.10.11 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14 PLYG-SC 10130.06.16-3 PLYG-10130.06.16-1 PLYG-SC 10130.09.16 PLYG-SC 13035.08.17 TAS 110/ASTM D4798 & D1970 ASTM D6164 TAS 103, TAS 110 & ASTM D 1623 ASTM D1623 TAS 103 & TAS 110 ASTM D 1970 & TAS 110 TAS 103 & TAS 110 ASTM D 1970 & TAS 110 ASTM D 1623 TAS 103 & ASTM D4798 Date 10/19/11 07/02/13 05/12/14 10/03/14 10/07/14 10/17/14 06/27/16 06/27/16 09/22/16 10/32/17 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MUAMHDADE COUNTY BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 21-0602.14 MIAM OME COUNTY Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 3 of 7 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick TR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Elastoflex S6 G, hot asphalt applied Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 4 of 7 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR Xe may be used in all the previous assemblies listed except metal roofing and roof file systems. Polystick TU Max may be used in non-structural metal roofing and roof file systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick Ht Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as *a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days) Polystick MTS Polystick IR Xe Elastoflex S6 G Polystick TU Plus Polystick TU P Polystick TU Max Polystick MTS Plus Winter Haven FL 180 90 180 180 180 180 180 Hazelton PA I N/A 90 N/A 180 N/A 180 1NlA 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 5 of 7 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) rile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (0) Profile MTS S6 G Polystick TU P TU Max MTS Plus MTS Plus with TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6:12 Tile without battens The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall be utilized during loading and installation of tiles. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. d a 0 N bOf Deck pf"fw MM POLYSPCKT R. 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 6 of 7 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 W metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the file manufacturers NOA, must be used on all projects for pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 VV /12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 7 of 7 MIMI E nnADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/eeonomv ICP Adhesives and Sealants, Inc. 12505 NW 44`h Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 17-0322.03 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 204124.07 MIAMMADE COUNTY Expiration Date: 05/10/22 e m Approval Date: 01/28/21 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof file adhesive Materials: Polyurethane SCOPE: This approves Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof the systems using Polyset AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications Polyset®AH-160 N/A TAS 101 Two component polyurethane foam adhesive ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPack® N/A Dispensing Equipment 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of Polyset AH-160 roof file adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Progerty Test Results Density @ 73°F ASTM D 1622 2.1 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 14 PSI Perpendicular to rise Tensile Strength ASTM D 1623 29 PSI Parallel to rise Water Absorption ASTM D2842 7% Moisture Vapor Transmission ASTM E96 2.3 Perms Dimensional Stability ASTM D2126 +0.03% Volume Change @ 400 F., 2 weeks -1.1% Volume Change @158°F., 100% Humidity, 2 weeks Closed Cell Content ASTM D6226 94% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 20-1124.07 MIAMMADE COUNTY Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 2 of 11 EVIDENCE SUBMITTED: Test Aeeney Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 NEMO ETC, LLC 4p-ICP-20-SSLAP-OI.B- Physical Properties 12/4/20 RI LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polyset® AH-160 shall solely be used with flat, low, & high file profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polyset' AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 3 of 11 INSTALLATION: 1. Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of Polyset° AH-160. 2. Polyset' AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof file assembly's adhesive attachment with the use of Polyset AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. Polyset' AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. Polyset AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPace 30 & 100 dispensing equipment only. 7. Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after Polyset AH-160 has been dispensed. 9. Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 Nall through plastic cement Paddy (Beneath Tile) (when required) \ Underlayment loin. BaKanioptional ° •e rAA-r EaveCourse ° in. 21n Eave Closure Nail through plastic cement (when required) Fascia Tile) Closure Nail through plastic re (when required) Paddy (Beneath Tile) Underlayment , 1 101n.a 2In. wide Battens /Ioptional i Eave course Fascia Weephole 10 In.. 21n. Eave closure Drlpedge Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 Tom) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) —23 (148.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile I. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) —23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 nun) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: O1128/21 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 Nall through plastic cement paddy (Beneath Tile) (when required) Undadayment 1 e y In, 21n. Bettans epticrul " Ease Course loin. Fascia f21n Ease closure plastic cement Paddy(Beneath THO Eave CJeaure Fascia nat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148A cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12 (77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nail through plastic ce (when required) Paddy Waneath rile) Undedayment o� 7 in.. . z in. Battens optional Eave Course Fascia Weephole 10In.2In. Eavedosnre Dtipedge High Profile / Single Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm') - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 20.1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Mil through plastic cement Paddy(between tllesi (when requhedlI •. I eaaensoptionalI 1 paddy hinder toe) t�z • ' Single paddy' y •' ontop of tile �•' i �./Yaln. �' wgk�padr under Ol Singlepaddy Im undedayment 2a a In. a e10ItL` cs..aoawe Flat/Low Profile Tile Mo through plastic cement Si * paddy under toe (when required] Pa" Ihetween tiles Battens Addy lunder tile; optional e singklsaddy, on top of the a �iaaln. y 2:ak Sing9le paddy at urMedaymeM I0 2In. Ease Dean Fare Course Fast Moaum ProlliaTilo On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the the being set. Leave approximately 411(101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 m2 (109.7-148.4 cm) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in' (51.6-58.1 cm2) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: O1/28/21 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nail tNoughpiutic Single paddy under file Iwhen requkera Paddy (between tiles) ba tens optiorsal Paddy Iwrder tllel v s:ryiedy won 4x4In. Si,* 2a4in w top tie— Eaee Corse hsda Weephole toin. 2bL Eaee dosure Drip edge High Profile The MIAM4DADE COUNTY ,...e s 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x'/," (19 mm) paddy on top of the eave course rile surface as shown, on top of the strengthening rib for flat rile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm?) - 11 (71cm2) square inch adhesive contact with the underside of the file at the overlap and 7 (45.2 cm2) - 9 (58.1 cm) square inch adhesive contact with the underside of the file at the head of the tile. Continue in same manner. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 10 of 11 ADHESIVE PLACEMENT DETAIL Two PIECE BARREL t) Place enough adhesive to achieve 65 to 70 sq.in. Steep pitch applications in contact with the pan tile. when required) 2) Tom covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in.contaa area. Underlavmetw Sheathing Eavedosure (meter shown) WeephoIt Fa s iaeoard Remove top portion of the cave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel -High Profile Tile APPROVED Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm) square inch adhesive contact with the underside of the pan tile. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm) - 25 (161.3 cm) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) milers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 11 of 11