Loading...
RF-05-22-1138Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 06/02/2022 Permit NO.: RF-05-22-1138 Permit Type: Roof Work Classification: Metal Permit Status: Approved Expiration: 12/02/2022 Location Address Parcel Number 10010 NE 1ST AVE, Miami Shores, FL 33138 1132060131441 Contacts DAVID SOLOMON Owner DADE PROFESSIONAL ROOFING Applicant 10010 NE 1 AVE, MIAMI SHORES, FL 33138 DORIAN LONIN GODOY Mobile: 3055421131 david@davidhuntsolomon.com 971 NW 35 AVE, MIAMI, FL 33125 Business: 7864125354 GODOYDORIAN@YAHOO.COM Mobile: 7862909073 MODERN COATING SYSTEM LLC Contractor ROGERCARO 2980 NW 66 ST, MIAMI, FL 33147 Mobile: 7863263652 Description: RE ROOF TO METAL ROOF - MATTE BLACK Valuation: $ 38,000.00 Ins ection Requests: OS 762-4949 Total Sq Feet: 2,925.00 Fees Amount Application Fee - Other $50.00 CCF $22.80 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $7.60 Planning and Zoning Review Fee $35.00 Roofing Fee $250.00 Technology Fee 57.50 Total: $380.40 Payments Date Paid Amt Paid Total Fees $380.40 Credit Card 06/02/2022 $330.40 Credit Card 05/05/2022 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. 6_Z—ZOZO Authorized Signature: Owner / Applicant / Contractor / Agent Date June 02, 2022 Page 2 of 2 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC Miami Shores Village ENTERED MAY 05 2022 Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY. Tel: (305) 795-2204 Fax: (305)756.8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 Master Permit No, ICpF- 6s-22- 11-R8 OOFING PLUMBING MECHANICAL ❑PUBLICWORKS JOB ADDRESS: �- 1)13-144 Sub Permit ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS SI,.),/s ,r,L 3317f the Building Historically Designated: yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): D(:vID r✓WMoIj Phoned: Address: 3` 54 rZo�/r.1 ro,)^ %}OtA-t, City: / •) ) 4W 1 Qom" H State: Email: A J I d d?l'/O CONTRACTOR: Company Name: 1 "in coc �v. % 54� fv'\ Phoneit: 2!J1! -3-74 -36SZ Address: 1.0 City: k$04, ' State: Qualifier Name: I \Cc Cqs+ v �I vnonerr: State Certification or Registration q: Certifica /'2O D te of Competency M _ DESIGNER: Architect/Engineer: QCt�V/70� anQYClh00•C-Ong Phoned: Zip: -M--32f--36s2- Address: City: State: ZIP: Value of Work for this Permit: $ ;%000' 0 Square/LinearrFFootage of Work: 24 2 Type of Work: ❑ Addition ❑ Alteration ElD/New Reppair/Replace ❑ Demolition Description of Work: V24- Qcy F ' 'T'VC1 Qd� ` 0 M¢'kc` e�ooc-- Specify color of color thru Submittal fee $ Permit Fee $ Scanning Fee$ RadonFee$!:?•UIl �'1 C Technology Fee $ f • J O Training/Education Fee $ Structural Reviews $(J caC CO/cc $ Notary Double Fee $ Bond $ TOTAL FEE NOW DUE $ • 4 (Rev1sed02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address city State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the Issuance of a permit and that all work will be performed to meet the 'standards of all laws regulating construction in this Jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing Information Is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the Issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (>) daysA the building permit is issued. In the absence of such posted notice, the Inspection will not be approved and a or AGENT will be charged. The foregoing Instrurr(€nt was acknowledged before me this /n _ 1 day of�r, , 20 1_ by 0,,J 5D(OP-011 , who is personally known to Signature_l/� CONTRACTOR The foregoing Instrument was acknowledged before me this p 1 i day of %ice 20 Z, by K ;d/ who Is personally known to me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY -PUBLIC! r Sign: Sign: Print: '1 Q Print: "g4!2; j`taxn4" . .:........... °.`. LEANDRA HERNANDEZ J'r°"'+ Seal: y W4r :_ Seal: ;9:, LEANORA HERNANDEZ • ,. Notary Public - State of Florida Notary. Public -State or Florida :. Commission a HH 119351 Commissiw • HH 119351 My Comm, Expires Apr 20. 2025 My Comm. E%PIreS Apr 20. 2025 14111W###WWW##M# APPROVED BY Plans Examiner Zoning Structural Review (Revised02/24/2014) Clerk This Document Prepared By: Maria D. Sariol, P.A. 2525 Ponce de Leon Boulevard Suite 300 Return to: Adams Gallinar, P.A. 1000 Brickell Avenue, Suite 300, Miami, FL 33131 Parcel ID Number. 11-32-06-013-1441 Warranty Deed This Indenture, Made this 2nd day of May, 2022 A.D., Between Alberto Lopez and Valeria Navarro, husband and wife of the County of Miami -Dade, State of Florida, Grantors, and David Hunt Solomon, a single man whose address is: 10010 NE 1st Avenue, Miami, FL 33138 of the County of Miami -Dade, state of Florida, Grantee. Witnesseth that the GRANTORS for and -in consideration of the sum of TEN DOLLARS ($10) DOLLARS, and other good and valuable consideration to GRANTORS in hand paid by GRANTEE, the receipt whereof is hereby acknowledged, have granted, bargained and sold to the said GRANTEE and GRANTEE'S heirs, successors and assigns forever, the following described land, situate, lying and being in the County of Miami -Dade, State of Florida to wit: Lot 23, Block 10, AMENDED PLAT OF MIAMI SHORES SECTION NO. 1, according to the Plat thereof, as recorded in Plat Book 10, Page 70, of the Public Records of Miami -Dade County, Florida. Subject to easements, restrictions and reservations of record, without affirmation or restatement of same, and taxes for the year 2022 and thereafter. TOGETHER, with all the tenements, hereditaments and appurtenances thereto belonging or in anywise appertaining. TO HAVE AND TO HOLD, the same in fee simple forever. AND, the Grantors hereby covenant with said Grantee that the Grantors are lawfully seized of said land in fee simple; that the Grantors have good right and lawful authority to sell and convey said land, and that said land is free of all encumbrances, except taxes accruing subsequent to December 31, 2021. and the Grantors do hereby fully warrant the title to said land, and will defend the same against lawful claims of all persons whomsoever. In Witness Whereof, the Grantors have hereunto set their hands and seals the day and year first above written. Signed, sealed and delivered in our presence: (Witnesses as to both) n0a 1) - i�-Ik- -�/c Printed Name:��� Witness Printed Nam : t Witness State of Florida County of Miami -Dade P.O. Address: 2901 NE 1 st *ye , Apt. 400, Miami, 33 7 (Seal) Valeria Navarro P.O. Address: 2901 NE 1 st Avenue, Apt. 400, Miami, FL 33137 The foregoing instrument was acknowledged before me by means of [ X ] physical presence or [ ] online notarization, this 2nd day of May, 2022, by Alberto Lopez and Valeria Navarro who are personally known to me or who have produced their Florida's driver license as identification. Printed Name: Notary Public My Commission Expires: @Emu IA o. SaRlol. lic - State of Florida sion 4 HH 005749Expires Aug 19, 2024 National Notary Assn. Property Search Application - Miami -Dade County Page 1 of I OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-013-1441 10010 NE AVE Miami Shores, FL 33138-2308 Property Address: Owner ALBERTO LOPEZ VALERIA NAVARRO Mailing Address 10010 NE 1 AVE MIAMI SHORES, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SO Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT Beds I Baths I Half 3/2/0 Floors 1 Living Units 1 Actual Area 2,445 Sq.Ft Living Area 1,701 Sq.Ft Adjusted Area 2,073 Sq.Ft Lot Size 6,410.1 Sq.Ft Year Built 1962 Assessment Information Year 2 2020 2019 Land Value 2,38 $192,380 $192,380 Building Value ?173,137 $144,281 $144,281 XF Value 0 $0 $0 Market Value $365,517 $336,661 $336,661 Assessed Value $365,517 $336,661 $335,057 Benefits Information Benefit Type 1 2021 2020 2019 Non -Homestead Cap Assessment Reduction Homestead Exemption $25,000 F$!i,604 Second Homestead Exemption 1 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 153 41-6 53 42 MIAMI SHORES SEC 1 AMD PB 10-70 LOT 23 BLK 10 LOT SIZE 55.740 X 115 OR 17908.1654 1297 4 Generated On : 5/5/2022 Taxable Value Information 20211_ 2020 2019 County Exemption Value $50,000 $0 $0 Taxable Value I S315,5171 $336,6611 $335,057 School Board Exemption Value $25,000 $0 $0 Taxable Value 1 $340,517 $336,661 $336,661 City Exemption Value $50,000 $0 $0 Taxable Value 1 $315,517 $336,661 $335,057 Regional Exemption Value $50,000 $0 $0 Taxable Value $315,517 $336,6611 $335,057 Sales Information Previous Sale Price OR Book -Page Qualification Description 07/26/2020 $466,000 32038-3494 Qual by exam of deed 05/27/2010 $293,000 27309-0291 Qual by exam of deed 04/01/2004 $319,000 22251-4000 Sales which are qualified 07/01/2003 $210,500 21467-2637 Sales which are qualified The Offloe of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:/Aw .miamidade.gov/info/discialmer.asp Version: hUps://www.miamidade.gov/Apps/PA/propertysearch/ 5/5/2022 RtE�EIVED Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dade County-:- Section A (General Information) BY. Master Permit Number: Process Number: 0 Contractor's Name: () rn cn'q' `r q S 6A-drn 1L C. Job Address: l 0 0 10 N 6 t AL) C- ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar / Adhesive Set Tile ❑ Asphaltic Shingles Metal Panel/ Shingles ❑ Wood Shingles / Shakes ROOF TYPE ❑ New Roof ❑ Repair ❑ Maintenance Reropfjpg„ a Q Recovering ROOF SYSTEM INFORMATION ..... Low Slope Ro red (ftZ) Steep Sloped Roof Area (ftz) „ , Total ZG ZS .....���5 Are there gas vents on the. roof? ©Yes O No If Yes what type? Q Natural , ©LPX Is there an existing roof top Solar System? © Yes O No If yes will it be reinstalled? 0Yes:'0 No Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. iLEci2 ►A5 Miami 5 Zoning Building compliance Date Repo Federal, to G5 CITY an MIAMI-DADE COUNTY REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to ex- plain to the owner the content of this form. The owner's initials in the designated space indicates that the item has been explained. 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are 1�2 for the rP u ose of providing that the roofing system meets the wind resistance and water intrusion perfor- mance mance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. Ea2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in Amm accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums etc.). In buildings with common roofs, the roofing contractor nd/or owner O 0 6000 000000 P O O O should notify the occupants of adjacent units of roofing work to be performed. ° ° 0 ° ° ° ° ° P P O 0 0 0 0 i;'Oe PPP000 0 004. Exposed ceilings: Exposed, open beam ceilings are where the underside.o;roof decking c;n be° viewed from below. The owner may wish to maintain the architectural appe�pamvee°; therefor" roofing nail: penetrations of the underside of the decking may not be acceptable. The owner pro41ft the optittrrermaintesging° 0 0 0 0 0 0 0 0 0 0 00000 this appearance. ° ° 0 0 ° 0 0 000 0 P P P P P P O 0 0 0 0 0 0 0 O 0 S. Ponding water: The current roof system and/or deck of the building may not �Irai-n well ae d may cau Qe wao ° ter to pond (accumulate) in low-lying areas of the roof. Ponding can be an i0dication ofostry� tvral dastress° and may require the review of a professional structural engineer. Ponding maalAdrten t4 lift expe(:M and performance of the new roofing system. Ponding conditions may not be evident untAhe.Qriginal roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. 8. Existing Sol r Systems: The re -installation of an existing roof mounted photovoltaic system requires a seP arat rmit. Permit must be obtained in order to finalize the roofing permit. DATE OWfY[R'S/AG[1V IVATI! CONTRACTOR'S IGNATURE PERMIT NUMBER LS .ti: . G o o PROPS ESS STATE ZIP sm� 123_01-297 3119 Miami -Dade County (MDC) 2020 HVHV Electronic Permit Form Section D Metal Roof Panel Roof System Manufacturer: IROOFING EXPERTS SERVICES INC MDC Notice of Acceptance (NOA): 1-0603.29 Minimum Design Wind Pressures (pst) from 2020 RAS-127 or Calculations per ASCE 7-16 (P1) Field: 74 (P2e) Perimeter Edges: 74 1 (P2n) Gable Perimeter. 108 (P2r) Ridge Perimeter. 108 (P3e) Overhang Corners: 108 (P3r) Ridge Corners: 128 Maximum design wind pressure from MDC NOA: 165 Complete the required roof assembly system components, if a component is not required mark the held N/A. Roof Slope: 4� 112 Roof Mean Height: 14 ft. Perimeter Width: ft. Deck Type: -- 5/8" Plywood Deck -- M Optional Nallable Surface: N/A Optional substrate attachment: N/A Optional Insulation: N/A Insulation Attachment. N/A Fire Barrier: �AF VERSASHIELD FIRE BARRIER Underlayment Type (UDL): F0_ ASTM D226TYPE Ilw/4 headlap Fastener Type & Spacing for UDL Attachment. F11/4 R.SNAIL & 1 5/8 TIN CAP 6" OC LA Optional Peel & Stick Membrane: JPOLYGLASS POLYSTICK MTS Metal Roof Panel: JENGLERT SERIES 1300 STEEL PANEL 0000 u � Drip Edge Material: .60 " 0 ° ° ° ° 0000y ° 00 0 0 000 0 GALVANIZED METAL ° ° ° ° ° ° ° fk ° ° 0000 ° Drip Edge Size & Gauge or gWetness� ° ° le a, 0 0o0000 ° 13" FACE 24 GA 000000 ° oleo °oeo ° 00 00 so a Drip Edge Hook Strip (conyggpN cleat) ° 000000 ° ° NIA le ° °° 0 0 ° ° 0008° Drip Edge Fastener & Attachment SpafhW:° ° O ° ° ° ° 1.25 RS NAILS @ 4" OC Screw Type, Size and Gauge for Clip Attachment. 2" clip w/ 2 screws & 6 "clip w/4 Screws Number of screws required per clip: 44screw, Screw Type, size, and Gauge for Through Panel Attachment, Sealing Washers Required: �10 CR WAFER HAD SPOLIER TIP Clip or Screw Spacing for Metal Panel Attachment: (i°1)= 12" in. o% (P2e): 12" in. o/c (P2n): 12" in. o/c (P2r): 12" in. o/c (P3e): 12" in.o1c (P30: 12" in. o/c We protect and beautify the world" BN4W114B BONE WHITE 870R5 - - — BURGUNDY 868V1 CHAMPAGNE 870D6 CHARCOAL 870R4 COLONIAL RED 870T15 DARK BRONZE BN4R126B DEEP RED BN4A126B DOVE GRAY 870G11 EVERGLADE MOSS 870G98 FOREST GREEN 870G99 HARTFORD GREEN 870G19 HEMLOCK GREEN 870T16 MANSARD BROWN 870K10 MATTE BLACK 870T14 MEDIUM BRONZE 8681129 METALLIC COPPER 870B11 PACIFIC BLUE BN4G120B PATINA GREEN 868A31 PRE -WEATHERED GALV 870BSO _- ROYALBLUE BN41106B SANDSTONE BN4N130B SIERRA TAN 87085 SLATE BLUE 870D7 SLATE GRAY BN4W117B STONE WHITE 870G9 TEAL 870R61E 11­11------- ITERRA GOTTA i GALVALUME-PLUS PPG Industrial Coatings PPG Industries 1S1 Colfax Street Springdale, PA 15144 USA Color Services www.colorrequests@ppg.com ASTM ASTM :ASTM - C-1549 C-1371 - E1980 TSR TE SRI 0.716 0.86 87 0.293 : 0.86 29 0.350 0.75 0.303 0.86 j ....32 ...31 0.368 0.487 • • ; •:7 !. 0.297 0 86 !10 0.413 0.86 .45 0.439 U.86 = 49 i 0.371 0.87 ••$0I 0.299 0.96 30 0.250 0.83 .� _••22 0.399 : - 086 .43 0.297 0.86 30.,. �- 0.250 0.83 22 0.272 0.87 27 0.350 0.75 32 0.264 0.86 25 0.383 0.86 41 0.350 0.75 32 0.250 0.83 22 0.588 0.86 69 0.452 0.86 51 0.307 0.86 31 0.370 0.87 40 0.662 0.86 80 0.287 0.86 28 0.354 - 0.86 37 0.680 0.10 54 MIMI®D MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590, F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) %'w .miamidade.eoy/economy Roofing Experts Services, Inc. 15240 SW 169 Lane Miami, FL 33187 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas, where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suSgdtid the use of such product or material within their jurisdiction. RER reserves the right to revoke this acaeAtAse if it is ir'etermineW S;:' Miami -Dade County Product Control Section that this product or material fails to meet the ;;gni1enents oftVge building code. This product is approved as described herein and has been designed to comply with the Florida Building Code inclu:Mg'; the High Velocity Hurricane Zone of the Florida Building Code. :""' •.... DESCRIPTION: Englert Series 1300 Steel Panel (2 in Clips and 6 in Clips) over Woe;Heck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, stW.&dfollo*Trfg" .. statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein] • • • • � • RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages I through 5. The submitted documentation was reviewed by Sifang Zhao, P.E. NOA No.: 21-0603.29 Expiration Date: August 05, 2026 Approval Date: August 05, 2021 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Metal, Panels (Non -Structural) Materials: Steel Deck Type: Wood Maximum Design Pressure —165.00 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Description Series 1300 Length: various TAS 125 Corrosion resistant, galvalume, preformed, Width: 16" standing seam. Coated, pre -finished, metal Thickness 0.024" (24ga) panels. Min. Yield Strength: 57 ksi. 2" Clip Length: 2" TAS 125 Corrosion resistant, galvalume, preformed, Width: 1" coated, pre -finished, metal chi;s I5Puse in Height: 1-9/16" ° °°° Field or Perimet4 pid:CornerA%of Roof. Thickness 0.020" ° °°°°°° °° ° °°°°°° 6" Clip Length: 6 1/4" TAS 125 Corrosion resistant, kalvaluNc, hformei' ° ° ° o Width: 1" coated, pre-finiftgL Victal caps far use irk, ° 00 Height: l .65" Perimeter and C�o$r.Areas of Roof. ° °°°°° ° Thickness 0.0276 ° ° °° °° °° °°°°°° Trim Pieces Length: varies N/A Corrosion resistaAta, �ivalume, preformed, ° ° Width: varies coated, pre -finished, trim piertS. ° ° ° ° ° ° ° ° Thickness 0.0276". o ° ° ° ° ° : 6060: 00 ° 00 ° ° ° EVIDENCE SUBMITTED: ° ° °° ° ° Test Agency Test Identifier Test Name/Report Date Morton International AS-0286-91 L Salt Spray Feb. 1986 ASTM B 117 AS-0286-91 T Accelerated Weathering Feb. 1986 ASTM G 23 Architectural Testing Inc. 01-32797.01 TAS 100 Nov. 1998 01-32797.03 ASTM E 8 Nov. 1998 Hurricane Test Laboratory, LLC. 0155-0615-05 TAS 125 Feb. 2006 Architectural Testing 92270.01-109-18 TAS 125 October. 2009 Intertek 05733.01-106-18 TAS 114 App G 01/05/17 NOA No.: 21-0603.29 Expiration Date: August 05, 2026 Approval Date: August 05, 2021 Page 2 of 5 APPROVED ASSEMBLIES: System A-1: Series 1300 Panel 16" Wide Deck Type: Wood, Non -Insulated Deck Description: New Construction 19/32" or greater plywood or wood plank. Slope Range: 211: 12" or greater (1": 12" effective w/2020 FBC 7t1' Edition) Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable building code, but in no case shall it be less than # 8d annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") the above attachment method must be in addition to existing attachment. Underlayment: Minimum Underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side - lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 %a" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA. Fire Barrier Board: ° ° ° Any approved fire barrier having a current NOA. Refer to a ct}rren %fire dimito°rylistin& for ° ° fire ratings of this roofing system assembly as well as the locitLoj? of the fire 1pj-�ier within, ° the assembly. See Limitation # 1. `00 Valleys: ° Valley construction shall be in compliance with Roofing Applic 0j Standard kkS 133 ° o with Englert's current published installation instructions. ° 0000 ° ; 00000 00000 Metal Panels and ° ° install the "Series 1300 Panel" and accessories in compliance with the currontopublisWeT ° Accessories: installation instructions and details in Englert's Installation Map'kgl oFlashings, penetrations ° valley construction and other details shall be constructed cbtlgplianee. w4h RoofM:° Application Standard RAS 133. ° ° ° ° ° ° °° 00 ° 00 ° ° ° Panels shall be installed with approved Panel Clips located at each panel A slide lap spaced at a maximum, listed in Table A below, parallel to roof slope, fastened with #10 wafer head spoiler tip corrosion resistant screws of sufficient length to penetrate through the sheathing a minimum 3/16 of an inch. Use 2 screws for the 2" clip and use 4 screws for the 6" clip. Standing seams shall be mechanically seamed to a 900 degree seam, (single lock). TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Perimeter and Corner'Y Maximum Design Pressures —69.25 psf —106.75 psf —165.00 psf Maximum Clip Spacing 24" o.c. 12" O.C. 12" o.c. Clip Size 2" Clip 2" Clip 6" Clip 1. Extrapolation shall not be allowed 2. Place a bead of Bostik 70-05A sealant in the lateral seams prior to seaming. NOA No.: 21-0603.29 Expiration Date: August 05, 2026 Approval Date: August 05, 2021 Page 3 of 5 SYSTEM LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e., field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e., perimeters, extended corners and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Buildim, ;ode and 0 0 Rule 61G20-3 the Florida Administrative Code. of , e e o u 0 606600 0 0 0 0 6. Panels be jobsite formed #(`s) 05.18.03 from Englert Rol4fbni3ed Prgdu*§ o e may roil with machine model G 000:00 a• o 000600 Association. e ooeeoo e a o 000eeo oos0 0 0 0 0 0 0 00o0ee 0000 0 0000e 0 0 ooe00o Goo 0 00000 0 0 o e 00 eo •0 090000 0 se0o,.o 0 0 0 0 V o 0 0 00 0 0000e0 0 0 0 0 0 0 00 0 0 0 0 0 000000 0e o 00 0 0 0 0 0 0 e 00 NOA No.: 21-0603.29 Expiration Date: August 05, 2026 Approval Date: August 05, 2021 Page 4 of 5 PROFILE DRAWINGS 2" CLIP DETAIL (FIELD AND PERIMETER AND CORNER OPTION) 0 00 0 0 0 O 000000 ea 0 o e IFOUR #10 A O 6MIN. 0 0 0 0 0 WER HEAD SCR ftlff EACH CLIP CLIPo EOMETRIC0 00 0 ® e os o a 0 (PERIMETER AN4 Cb"ER UPTIPN) 0 0 0 0 00 Bostik Sealant Before Seaming 90 degree 90 degree Seam Seam w/Bostik Sealant SERIES 1300 PANEL SYSTEM END OF THIS ACCEPTANCE 000000 0 0 0 0 e 0 e 0 a e 00a000 e e oo0eo 0 0 00000 000000 0 0 000000 0 0 00e000 0 e NOA No.: 21-0603.29 Expiration Date: August 05, 2026 Approval Date: August 05, 2021 Page 5 of 5 IMPORTANT! CONSULT ENGLERT TECHNICAL IMPORTANTI ENGLERT H/T UNDERLAYMENT DEPARTMENT WHEN SLOPE IS LESS THAN 3:12 REQUIRED ON SOLID SUBSTRATES & RIGID INSULATION. FOR REQUIRED VALLEY FLASHING WIDTH. SEE DETAIL# R14 FOR INSTALLATION INSTRUCTIONS. N ENGLERT www.englertinc.com 800-364-5378 G00X6WPXWlaAMW _.W, WAARRNf V Nbi ddOtlm. WlI2N SfiE CONDIS10t10CMOtli. (2) ROWS%" ENGLERT, IN -SEAM TUBE SEALANT (TYP.) PANCAKE SCREW PER PROJECT REQUIREMENTS (TYP.) ENGLERT OFFSET CLEAT CONTINUOUS (TYP.) ENGLERT BUTYLTAPE SEALANT CONTINUOUS (TYP.) FILL PANEL ENDS w/ ENGLERT IN -SEAM TUBE SEALANT (TYP.) INSTALL ENGLERT TUBE SEALANT BEFORE INSERTING PANEL HEM (TYP.) ENGLERT VALLEY ROOF VALLEY OFFSET CLEAT 5�y,�V• 000000 00 0 �- 0 0 00 0 0 0 0 0 0 0 Ooo 0 0 0 0 000/° 0 000 tSE�9 l7 /�,�io7o 0 ova 00000 a / 0 00 00 0 0 0 00 0 90600 oev000 o00000 0 0 0 0 0 0 0 a 0 0 0 0 0 0 O 0 0 0 0 00 0 0 0 0 0 0 0 0 0 O 0 0 0 0 00 0 O oovoo° 0 0 Ol.TAfl 3U("eCTT* CHANGE wmtotar Ncmc . retail # R14.1 1300 SERIES ROOF PANEL Z CLOSURE cur Meir eErwEL14*** PANEL. SET IN 2 t:)14T: BEADS OF;' POP RIVET ONE SIDE SEALANT AND C*AXID VERTICA6UV ONLY 0 24' D.C. AT SEAMS (SEkLA"aW%ADED BY. #10-12X1- SCREWS ENGLERT) 1 (3) PER PANEL BOX PANEL END FLASH :6%.: FLASH "A" ASTM ID226 30# FELT (BY ENGLER7) ENCLERT HT UNDf RLUAYMENT SOLID DECK 1p, 15 A FLASH "A* ENG LERT RIDGE DETAIL -L O O CA m ;a m CA I M 0 0 m 0 pq... ENGLERT TUBE SEALANT COLOR MATCHED HEX SCREW W/ BONDED SEALING WASHER PER PROJECT REQUIREMENTS ENGLERT REGLEVRECEIVER WRAP UNDERLAYMENT UP WALL ENGLERT BUTYL ENGLERT HEADWALL FLASHING TAPE SEALANT ENGLERT Z-CLOSURE CUT TO FIT BREAD PAN FOLD BETWEEN SEAMS W/ENGLERTTUBE w SEALANT ON ALL CUT EDGES )TYP.) z S.S POP RIVET(SCREWES OPTIONAL) W N Q ENGLERT BUTYL TAPE SEALANT � ac CONTINUOUS (TYP.) `� a PANCAKE SCREW PER PROJECT REQUIREMENTS @ 3" O.C. MAX. . •' • •. THRU Z-CLOSURE (IYP.) ' ... wooOP`LRp81 j.... .. ENGLERT ROOF HEADWALL •� k neren � awl= COUNTER FLASHING W/SEALANT R18.1 p@lpRIC Bpi! pBltt AB@ v MM. •l� LWLiR4 mm llbLPU. pllpt �p8 Wt9QlOp DVILE. V.c DIGt�IG WC®.8Y ENGLERT TUBE SEALANT ENGLERT BUTYL TAPE SEALANT COLOR MATCHED HEX SCREW W/ BONDED SEALING WASHER PER PROJECT REQUIREMENTS ENGLERT COUNTER FLASHING WRAP UNDERLAYMENT UP WALL HEX SCREW PER PROJECT REQUIREMENTS ENGLERT SIDEWALL FLASHING ENGLERT RETAINER-Z CONTINUOUS ENGLERT BUTYL TAPE SEALANT- CONTINUOUS ENGLERT ROOF PANEL UPTURN LEG PANCAKE SCREW PER PROJECT REQUIREMENTS @ 3" O.C. MAX. I ROOF ASSEMBLY (SEE DETAIL R08) "MN. z"i �+ ENGLEgr www.englertlnc.com 800-36"378 MNfl1C IIlf5'f pMCrl0ASM9MY Q. 0) 4 ROOF SIDEWALL COUNTER FLASHING W/ SEALANT ao•o 0 • 0 0 okloo 0000.0 0 0 0 0 a o a 000 0 0 o a O 80000- 0 •o • 0.0.00 0.0400 0 0 0 O O D 0 0000 oe0000 O O 0 O O O 0000 0000 0s•o• 000000 O Oa0 o p 00000 O O O O tl 00 00 Otl O 00.000 9 i 0 a 0 0 O ° p O O P 0 e 0 O O a 000000 O O O t 0 O 00 O O ° 0 a 000000 00 0 00 0 0 0 o s o 0 00 DETAIL SUBIECTTO MANGE wmiourNO ICF- R22 .i. w z r CAUTION -THIS DETAIL MAY PIN PANELS AT THIS POINTI PIPE, TUBE STEEL, or ANGLE ENGLERT TUBE SEALANT 0000 STAINLESS STEEL BAND 0 0 ° 0000 0 (IF REQUIRED BY ROOF JACK MAwk1WTURER)0 , .. 000000 � ° e p0 p O 000000 ° PIPE BOOT 0000 (DEKTITE OR EQUIVALENT) O° ° 0000 0 O 0 0 0 0 0 0 0 O. HEX SCREW w/ BONDED SEALIgginl SHER 0 O ° o @ 1" O.C. INTO PANEL FACE ONLY 0 0 ° O400 O O 0 0 ENGLERT TUBE SEALANT ° 00 ° O O O 0 0 O O O 00 O O 00 00 ° 0 O O 0 00 IENCLERT- ROOF PENETRATION � suM=� urrTuaus uozstc. %;, www.englertine.com $00-364-5378 PIPE BOOT Detail # R��.1 8W� 3"0M.WAIUMPOM WARNMM M0r 0AK= WHINSMCONOMONMFM M( �+ SPEQHC E1iGW [ScOAf O 0°°°00 ° ° ° 0 0 0 0 0 0 0 0 000000 O 0 00000 0 0 00000 Ooeeoo O 0 ° 0 0 0 O O O 0 O 000000 O O u NOTE: MANSARD PARAPET CAP SHALL HAVE B' MIN. OVERLAP w/ Z ROWS OF ENGLERT BUTYLTAPE SEALANT FASTENED w/ MANSARD PARAPET CAP MA ENGLERTCOLOR MATCHED HEX SCREWS w/ BONDED SEALING WASHER (PITCH AWAY FROM ROOF) PER PROJECT REQUIREMENTS WRAP UNDERLAYMENT BREAD PAN FOLD OVER EDGE & DOWN WALL PANCAKE SCREW PER PROJECT PANCAKE SCREW PER 2 MIN. REQUIREMENTS @ 3' O.C. MAX. PROJECT REQUIREMENTS PITCH THRU Z-CLOSURE (TYP-) (TYP.) ENGLERT Z-CLOSURE CUTTO FIT BETWEEN SEAMS w/ ENGLERT TUBE ENGLERT EXTENDED SEALANTON ALLCUT EDGES (TYP.) EAVE TRIM , COLOR MATCHED HEX SCREW PANCAKE SCREW I w/ BONDED SEALING WASHER ENGLERTCLEAT ) ` ENGLERT BUTYL / TAPE SEALANT / ��� CONTINUOUS(jwre. w Qn� ��� p � :•: •� lg2.��Y .•..• ��cY I P T zli N CLEAT ALWAYS REQUIRED i ENGLERT w w.engleftlm� 8003645378 MI HEM 5"MI. \ I 3" IN. EXfE ION xz �ypp [jam Id/I66Fy_Tii7 R12.3 f I 09 ENGLER WVJ1 englertinc.com 800-364-5378 GLNLIUCOMMCKLA WAOLr SROW f. YIATtRTXimtss LYARR&-M NQr^in= EMSE TC ROOF PENETRATION GOOSE NECK DETAIL. 0 0 0 00 0 110 O )O Doo 0 0 10 0 'o ,00 0 0 0 0 0 00 0 0 0 0 0 00 ?GRIP SCRE:YY DETAIL SUIDECT To CHANGE W SNITHOUT NanCE R26. 1 9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 000000 0 0 00000 0 0 00000 000000 O 0 0 000000 0 0 000000 0 0 1 0 0 0 0 0 0 O 0 00000 O 00000 0 0000 O 0 0 0 0 0 0 0 0 0 0 O 0 0 00000 0 0 0 0 0 0 0 C 0 1 � 2/27/2020 h - TGFU.R18970 - Roofing Systems UL Online Certifications Directory Home Quick Guide Contact Us UL.com TGFU.R18970 Roofing Systems P4ge Bottom Roofing Systems See General Information for Roofing Systems ENGLERT INC ppp°°o O O O O O O 0000 R18976o0° 1200 AMBOY AVE 0O° ° O p 000 0 0 0 O 0 0 0 0 0 0 PERTH AMBOY, NJ 08861-1920 USA O ° ° ° ° ° ° ° ° 0 0 0 0 000000 0 0 0 0 O 0 0 0 0 0 0 O O ° 00060 O O O O O O O O OTHER SYSTEMS66096°° 0 0 0 0 0 0 O O O 0 0 0 O . O 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 ° ° ° Class A ° ° O 00 O O O O ° 0 0 0 0 0 0 1. Deck: C-15/32 ors aced p o O O O ° ° ° p° O ° ° O o 0 0 p 0 0 0 ° O Incline: Unlimited Impact: 4 ° ° ° O sheathing 09 Underlayment: — One layer "VersaShield Underlayment", mechanically fastened. Ply Sheet: — One layer Type 30 base sheet or "VersaShield", mechanically fastened. Panels: — — Steel, zinc or copper roofing panels, designated "Series 1000", "Series 1100", "Series 1101 ", "Series 1300", "Series 1500", "Series 2000" or "Series 2500", mechanically fastened. 2. Deck: C-15/32 or spaced Incline: Unlimited Impact: 4 sheathing Underlayment: — One or more plies "VersaShield Underlayment", mechanically fastened. Panels: — Steel, zinc or copper roofing panels, designated "Series 1000", "Series 1100", "Series 1101 "Series 1300", "Series 1500", "Series 2000" or "Series 2500", mechanically fastened. 3. Deck: C-15/32 Incline: Unlimited Impact: 4 Barrier Board: — 1/4 in. min. G-P Gypsum DensDeck® with all joints staggered a min of 6 in. from the plywood joints. Insulation (Optional): — Fiberglass, polyisocyanurate, perlite or wood fiber, any thickness. Membrane: —Any UL Classified modified bitumen system, BUR system or CPE, CSM, CSPE, EPDM, NBP, PIB, PVC, TPO or THE membrane system suitable for use with any roof insulation. Panels: — Steel, zinc or copper roofing panels, designated "Series 1000", "Series 1100", "Series 1101 "Series 1300", "Series 1500 "Series 2000" or "Series 2500", mechanically fastened. Last Updated on 2014-06-17 file:///ClUsers/Lucy Iglesias/Desktop/MRS DocumentsAvebsite/resourcesfrGFU.R18970 - Roofing Systems UL.html 112 1 427/2(90 TGFU.R18970 - Roofing Systems e Questions? Print this age Terms of Use Page„ Top © 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: V 2016 UL LLC". also a O q e oeoo 000000 e . e ee • O ego a q O O e p 000006 O 06 O 000006 0a000a O O 0 DODO 0 0 0 0 sGOOD: O � O *Dee 0606 e0000 0 0 0 0 0 0 1 O O a O O Oe 0 Oo O O e O O 00 00 00 L 000000 0 0 0 0 0 0 O O O O O O O e 00 O O 000000 O O q 0 0 a 00 0 0 s 0 o soOOeO 00 o OO o 0 o e 0 0 O 00 file:///C:/Users/Lucy Iglesias/Desktop/MRS Documents/website/resources/TGFU.Rl8970 - Roofing Systems UL.html 2/2 MI MEMO PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w%w.miamidade.aov/economy Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted 1tr.1rmer, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, ttlodiN or sus"Ild the use* of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if t it% determined by Miami -Dade County Product Control Section that this product or material NiI *to meet the requuemenfs * • of the applicable building code. ... • .... �.... This product is approved as described herein, and has been designed to comply with the FlUdaSuilding•CQde . • • •, including the High Velocity Hurricane Zone of the Florida Building Code. ... ..:..' DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, cig Mate tfnd following.... ; statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein • • ' RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.17-0614.22 and consists of pages I through 7. The submitted documentation was reviewed by Jorge L. Acebo. MIAMIDADE COUNTY V7174m, NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page I of 7 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS, APP PRODUCTS DESCRIPTION: Product Dimensions Polystick IR-Xe 65' x 3' Or 33.4' x Manufacturing 3' Location # 1 & #2 60 mils thick Polystick TU Max Manufacturing Location # 1 & #2 Polystick TU P Manufacturing Location #2 Polystick TU Plus (Surface Printing) Manufacturing Location # 1 & #2 Polystick NITS Manufacturing Location #2 Polystick MTS Plus Manufacturing Location #2 Test Product Specification Description ASTM D 1970 A fine granular/sand top surface self -adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. 65'8" x 3'3-3/8" TAS 103 and 60 mils thick ASTM D 1970 32'10" x 3'3-3/8" TAS 103 and 130 mils thick ASTM D 1970 65' x 3'3-3/8" 80 mils thick 65'8" x 3'3-3/8" 60 mils thick TAS 103 and ASTM D 1970 TAS 103 A rubberized asphalt self -adhering, polyester reinforced waterproofing membrane. Designed as a a roof the underlayment. 0 0 0 0 ° ° ° 0 0000 000600 A rubberized asphalt waterproofin; membsarne..glass- ,0 fiber/polyester reinforced, vAt4ra granular sarfale ° o 0 0 : ° designed for use as a tile roof 4i layment. o : 0 0 0 0 0 0 000 0000 0 O A rubberized asphalt self-adhesimg; glass°fAcri�olyestw° ° ° reinforced waterproofing membpam. Designed -as a mcidl° 0 ° ° roofing and roof tile underlfy2 &tt. 00 ° 0 0 0 0 0 0 °000°° 0 ° ° ° ° ° ° 0 0 00 O 000000 0 0 O A homogeneous, rubberize&as/ait wate*Tr6dfing o ° ° 0 0 : membrane, glass fiber reinforced with po`,yelefinic film ° on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt waterproofing 60 mils thick membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Elastoflex S6 G 32' 10" x 3'3 %" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location #2 use in roof tile underlayment systems. MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 2 of 7 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Trinity ERD P37300.10.11 TAS I lO/ASTM D4798 & D1970 10/19/11 P37590.07.13-1 ASTM D6164 07/02/13 P45270.05.14 TAS 103, TAS 110 & ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103 & TAS 110 10/07/14 P43290.10.14 ASTM D 1970 & TAS 110 10/17/14 PLYG-SC 10130.06.16-3 TAS 103 & TAS 110 06/27/16 PLYG-10130.06.16-1 ASTM D1970 & TAS 110 06/27/16 PLYG-SC10130.09.16 ASTM D1623 09/22/16 PLYG-SC13035.08.17 TAS 103 & ASTM D4798 10/32/17 LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's nape yr logo, city and state of manufacturing facility and the following statement: "Miami -Dade Count}: Product Conflbt gApproveds or the Miami -Dade County Product Control Seal as shown below. °' a '' e' o 000060 0 oe 0 e06404 LAM1 D DDE COUNTY 0 0 0 e 6 0 0 0 0 0400 0 o 066e0e 000e e a e 000e o 0000 00000 ooeo0o • • 0 0 coo 0e00 oo o 0 0 00 00 00 0 oeeeoo 000000 BUILDING PERMIT REQUIREMENTS: O e • O 0 � ' e O 00 O O O O s 0 0 e Application for building permit shall be accompanied by copies of the following: e ° e 0 ° ° 0 eo 0 0 e e e o 00 0 1. This Notice of Acceptance. 0 0 : ° 00 e 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 21-0602.14 MlAMIAPPRO COUNTY Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 3 of 7 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank 0 0000 O°° o System Type E(2): 0 O 0000 000000 Anchor sheet mechanically fastened to deck, membrane adhered ° ° 0 ° 0 0 0 o 0 0 Anchor/Base Sheet: ° One or more plies of ASTM D 226 Type 11 or ASTM D 2626. 0 0 0 : 0 ° 06 ° ° O O O 0 0 Fastening: 000009 0 0 0 Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at adaWmum 4"Old¢ lap. (fir° a 0: base sheet only) o 00669 000° o 00000 Membrane: 0 0 00:000 0 000 00000 Elastoflex S6 G, hot asphalt applied ° s O 0 0 Surfacing: 00 00 00 O 000000 See General Limitations Below. 0 0 0 0.0 0 O 0 ® 0 ° 0 0 00 ° 00oon0 0 0 0 0 0 0 ° 00 0 0 0 0 0 oG00% 00 0 00 0 0 0 Deck Type 1: Wood, non -insulated : 0 00 ° Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 4 of 7 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of PolystW l be applied over the underlayment. ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° °° ° ° °°° ° GENERAL LIMITATIONS: ° ° ° ° ° ° 00 ° o ° ° ° ° o ° ° ° ° 00 ° °°°°°° 1. Fire classification is not part of this acceptance. ° ° ° ° ° ° ° 0000 ° ° °°°° °°°° °°°°° 2. Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphal�i;�iagles, wood°shakes° ° o ° ° ° and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assQmbk s. Goo ° 000000 : Polystick TU P may be used in all the previous assemblies listed except metal roofingp ° ° ° o°°°:° Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and;oof W systems. ° ° p ° ° ° ° : Polystick TU Max maybe used in non-structural metal roofing and roof the systems: ° ° ° ° °° ° °° ° ° ° Elastoflex S6 G may be used in roof tile systems only. ° ° ° ° 00 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days) Polystick MTS Polystick IR-Xe Elastoflex S6 G Polystick TU Plus Polystick TU P Polystick TU Max Polystick MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 Hazelton, PA I N/A 90 N/A 180 N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 21-0602.14 MWMFE)ADECOUNTY Expiration Date: 09/13/22 URTSYMApproval Date: 08/26/21 Page 5 of 7 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (E3) Profile MTS S6 G Polystick TU P TU Max MTS Plus NITS Plus with TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6:12 Tile without battens The above slope limitations can be exceeded only by using battens in accordance with the Approved 'Pite System Notice of Acceptance and applicable Florida Building Code requirements. When battens are requy0d.M& shall be utilized during loading and installation of tiles. ...... •' 10. Care should be taken during the loading procedure to keep foot traffic to a minimum atld IQ avoid dsopping of tale directly on the underlayment. Refer to Polyglass' Tile loading detail below for loadinAprosedure * two4les laid•: •' , perpendicular to slope followed by a maximum four tile stack parallel to the slope, fora fetaf of 6 ylbs;'for all underlayments except Polystick MTS which shall be loaded onto battens. Roofing riles is Mac Per Sack) 61 ... kbof Deck rreared with POUSTICKTU Roe 12 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 6 of 7 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Pol'y°glps Tile Loading Guidelines. See General Limitations #9 and #10. . ° ° ° ° ° 000000 . . • ° 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used gg all prqjgCts:for ...... .... pitch/slopes of T712" or greater. It is suggested that on pitch/slopes in excess of 6 'A" 9'. precautions should •be . 000000 taken, such as the use of battens to prevent tile sliding during the loading process. 0000 0000 0 . 7. Minimum cure time after membrane installation & before loading of roofing tiles is FdW fight (4-Hours. 00000 ° .....0 8. Polystick membranes may not be used in any exposed application such as crickets, expo%ad°valleys;er exposed' ° ° ° e ° roof to wall details. ...... ° ° . 9. Repair of Polystick membranes is to be accomplished by applying Polyglass POLYPLUS 5°d, Xtraf ley.56 ° . Premium Modified Wet/Dry Cement or Polyglass PG 500 to the area in need of repair; f9liolved by a patch of tfie ° ° ° Polystick material of like kind should be set and hand rolled in place over the area needing such repairpPatching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 21-0602.14 Expiration Date: 09/13/22 Approval Date: 08/26/21 Page 7 of 7 COUNTY MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this asceptannce if haistletermidt:tP':' by Miami -Dade County Product Control Section that this product or material fails to meet -the requirenMs of the applicable building code. This product is approved as described herein and has been designed to comply with the FJorida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. ' ..... ...... : DESCRIPTION: VersaShield® Fire -Resistant Roof Deck Protection and . • • • • • • • • •""' VersaShield® Solo- Fire -Resistant Slip Sheet ; • • ; • ; � • �: • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logy, city, state'and'tollowing statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 16-1216.02 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L. Acebo. APPROVED NOA No.: 21-1027.02 Expiration Date: 02/07/27 Approval Date: 12/02/21 Page 1 of 3 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: Fiberglass SCOPE: This acceptance is for VersaShield® Fire -Resistant Roof Deck Protection (a.k.a "VersaShield® Underlayment") and VersaShield® SoloTM Fire -Resistant Slip Sheet (a.k.a "VersaShield SoloTM"), as described in this Notice of Acceptance, for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Specifications Description VersaShield® Fire- 42" x 100' rolls ASTM D 226 •000 Non -Asphaltic fiberglass -based under jl pnt 0 ODD:* Resistant Roof Deck Type II o° o and/or fire barrier. o 00 0 0 000 a a 0 Protection aeaeea ° 0000 °++O°O VersaShield® Sol6TM 72" x 166.7' rolls UL790 aoso+o a Non -Asphaltic fiberglas°swbased slip §he�ond/or a a ooeooa fire + Fire -Resistant Slip Sheet 36" x 166.7' rolls barrier. ° ° ° ° 0000 ° ° o e ° a o0s000 ° 000 0 aeeea 0 0 00 0• 0 0 oo + 0000eo 0 ooe0+0 ° o 0 MANUFACTURING LOCATION: o e o e 0 ° 0 0 ° ° ° ° ° ° 1. Conover, NC ° 0 e a e 00 0 ° 0O ° ° ° o a o 0 00 o 0 .00000 o EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials PR1376TO192 ASTM D 226 09/16/21 Technologies GAF-748-02-01 ASTM D 226 12/12/16 ELK-063-02-01 TAS 100 09/27/01 UL LLC R10689 UL790 04/30/21 R 1306 UL790 11 /23/21 INSTALLATION: 1. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoloTM Fire -Resistant Slip Sheet shall be installed in strict compliance with applicable Building Code. 2. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoloTM Fire -Resistant Slip Sheet shall be installed with a minimum 4-inch head lap in a shingle layer fashion. 3. VersaShield® Fire -Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type II underlayment. NOA No.: 21-1027.02 M[AMI. ME COUNTY Expiration Date: 02/07/27 999A. , . W Approval Date: 12/02/21 Page 2 of 3 LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. VersaShield® Fire -Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. VersaShield® SoIoTM Fire -Resistant Slip Sheet shall not be left exposed to the weather. 4. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® SoIoTM Fire -Resistant Slip Sheet are a component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -Resistant Slip Sheet may be used with any approved roof covering Notice of Acceptance listing. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -Resistant Slip Sheet may be used as a component part of an assembly in the Notice of Acceptance. If VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -Resistant Slip Sheet is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. eeee 6. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® SoIoTM Fire-Resbstant. Slip Sheet. sere a neAA o d e asphaltic underlayment that may be used as a fire barrier for prepared roof assemblih.eto; fire clastfTation of ° e specific roof assemblies using VersaShield® Fire -Resistant Roof Deck Protection ois eVee�Shield®eSo1bTM Frr� e c e e Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire rat��8f this product. a e m e e e eoe coon o 0 7. All products listed herein shall have a quality assurance audit in accordance with theozl=6 Buil°dangtode and- 0 ° e Rule 61 G20-3 of the Florida Administrative Code. e o a o o c a o 0 0 e a e a 0 e o °oe 0 0 ooeoo0 oe so o 0 000000 0 0 LABELING: e° 0 0000ee e 0 All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's tr0 me orologe® city aril„ e e , o state of manufacturing facility, yellow line to identify the ASTM Standard designation or loje,,canSthe fctjhwft e o statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control°Sell°as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this material. END OF THIS ACCEPTANCE NOA No.: 21-1027.02 Expiration Date: 02/07/27 Approval Date: 12/02/21 Page 3 of 3 STONE WHITE' BONE WHITE REGALWHITE) NDSTONE ALMOND SIERRA TAN BUCKSKIN MEDIUM BRONZE m m AGED BRONZE* MANSARD BROWN GRANITE* !. MUSKETGRAY* PATINA GREEN FOREST GREEN TERRACOTTA CARDINALRED* (BRILLIANCE RED) INTERSTATE BLUE* (DEEPBLUESEA) AWARD BLUE' CHARCOAL* ANTIQUE BRONZE MIDNIGHT BRONZE' (DARK BRONZE) •• CITYSCAPE (DOVE Oanv)SLATE GRAY : .. IRON ORE (cHARCoaL eaAn HEKpCR GREEN HARTFORD GREEN BURGUNDY COLONIAL RED own TEAL MILITARY BLUE(SLATESLUE) PACIFIC BLUE SILVER (BRIGHT SILVER) P ZINC* P WEATHERED ZINC P (PREWEATHERED WLVALUME) ()= PREVIOUS COLOR P = PREMIUM M =.MILL FINISH LOW GLOSS COLOR = NEW COLOR CHAMPAGNE /' COPPER PENNY P AGED COPPER* /' DREXLUME" (METALLICCOPPER) V