Loading...
FW-05-22-1311Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 06/23/2022 Location Address Parcel Number 9210 NE 2ND AVE, Miami Shores, FL 33138 1132060133080 n�araa•«w...,_.a....,.,.�.. _ ..m �...... ,..w Contacts Permit NO.: F W-05-22-1311 Permit Type: Fence/Wall Work Classification: Wire Fence Permit Status: Approved Expiration: 12/23/2022 JUAN R SUTIL YAEL E LANIADO Owner 9210 NE 2 ST, MIAMI SHORES, 33130 Mobile: 7865436707 jsutil@aol.com OWNER Contractor Description: REPLACING EXISTING WOOD FENCE FOR A 6FT Valuation: $ 5,000.00 Inspection Requests: CHAIN LINK FENCE - BLACK WITH 2 GATES 305-752-4949 Total Sq Feet: 0.00 �7 �iri�r�num Fees Amount Application Fee - Other $50.00 CCF $3.00 DBPR Fee $5.63 DCA Fee $3.75 Education Surcharge $1.00 Planning and Zoning Review Fee $35.00 Scanning Fee $9.00 Technology Fee $9.38 Wire and Wood Fence Fee $325.00 Total: $441.76 Payments Date Paid Amt Paid Total Fees $441.76 Credit Card 05/23/2022 $50.00 Credit Card 06/23/2022 $391.76 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I oeftify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulatingegnstruction and z6ning. Futhermore, I authorize the above named contractor to do the work stated. AuthorizedySignature: Owner / Applicant / Contractor / Agent " Date June 23, 2022 Page 2 of 2 Miami Shores Village ENTERED Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 it] 11]101L0 PERMIT APPLICATION QBUILDING ❑ ELECTRIC ❑ ROOFING MAY 2 3 ZOZZ BY: FBC 20 Master Permit No. Fw- 0S-22- 1 31 I Sub Permit ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF C�-7 /' q� CONTRACTOR JOB ADDRESS: /(_/O /� �l�v /'7 /'/'�// S// ❑ CANCELLATION ❑ SHOP DRAWINGS Folio/Parcel#: 11 - 32f)(P - OL3 - 3060 Is the Building Historically Designated: Yes Occupancy Type: Load: Construction Type: Flood Zone: BFE: _ OWNER: Name (Fee Simple TitlesNho�Idep: Address:/ City: /X State: 2 Tenant/Lessee Name: Email: I / �� n r,/� CONTRACTOR: Company Name: h1 &C (lam � LAC' Phone#: Address: City: Qualifier Name: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: NO FIFE: j Y3--6� 91— 3-? /--� 155 Address: City: State: Zip: Value of Work for this Permit: $ '5077D Square/Linear Footage of Work: 3 7 Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: /t E-Ifr ,KI n/6 Ea'/.S'T/�✓ 6 &1004 [—eW C< &X -,� Specify color of color thru Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews 5 CCF $ CO/CC $ DBPR$ Notary, Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the jab site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature S=4v Signature v OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this /" 23 day of tO �-A 20 ZZ by JVCcYI 'Sd i who is personally known to me or who has produced bnV%'r5 L e- as identification and who did take an oath. NOTARY PUBLIC: The foregoing instrument was acknowledged before me this Z 3 day of20 -2-Z , by c] uo-`x Su A-� , who is personally known to me or who has produced P- Veers lC as identification and who did take an oath. NOTARY PUBLIC: Sign: Sign: \ / Print: V 4--C, Print: V V i \4 \�4�,PY Vlvlenne Yso ogP'..Y.P.,um ; Vivienne YaO Seal: �; ` Comm.:HH222410 Seal; _:, m_ Comm.0222410 Expires: Jan. 31,2026 ^`0 = a Expires: Jan. 31, 2026 Note Public -State of Florida Notary Notary Note Public - State of Florida mnuao ` °"` APPROVED BY Plans Examiner Zoning r lC)/4 Structural Review Clerk (Revised02/24/2014) OWNER BUILDER DISCLOSURE STATEMENT NAME: JI (14AI _5V 1L- DATE: ADDRESS: �Z /o NCF- 2 .fkgs� OOt11,f>V1 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 r22 F2 3 Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entities me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with -holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. Initial_Lm.,( 2. [understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. 1 understand that, as an owner builder, I am the responsible parry of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial ��f 4. )understand that 1 may build or improve a one family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates the exemption. Initial 5. 1 understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. Initial 671es 6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure thatthe persons whom I employ have the license required by law and by county or municipal ordinance. Initial 7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously Implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial 8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow these may subject to serious financial risk. Initial ' ✓ e 9. 1 agree that, as the parry legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govern owner -builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial V K 10. 1 understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850,487.1395 or http:/Jwww.myfioridalicense.com/dbar/vro/CilbAndu.htmi / Initial ✓ 11. 1 am aware of, and consent to; an owner -builder building permit applied for In my name and understands that I am the parry legally and financially responsible for the proposed construction activity at the following address: l Initial 12. 1 agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information that I have provided on this disclosure. I_e Initial V �/�/ Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of Contractor may be in civil court. It is also Important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. if you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verI ication acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this 2 3 day of AA 20 Z2 Q''' SU-V-, \ who was personally known to me or who has Produced there License or/ eL �rt V e� Lt &e'q:s�� as identification. OWNER t v I `z vi t,- �-( a o NOTARY`�.�°�«ro"rZ VrvienneYao uB`c_ Comm.:HH222410 Expires: Jan.31,2026 Notary public -State ofFlorkla Property Search Application - Miami -Dade County Page I of 2 OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-013-3080 Property Address: 9210 NE 2 AVE Miami Shores, FL 33138-2805 Owner JUAN R SUTIL YAEL E LANIADO Mailing Address 9210 NE 2 AVE MIAMI SHORES, FL 33138 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SO Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds I Baths I Half 5/4/0 Floors 2 Living Units 1 Actual Area 3,701 Sq.Ft Living Area 2,789 Sq.Ft Adjusted Area 3,073 Sq.Ft Lot Size 10,530 Sq.Ft Year Built 1991 Assessment Information Year 2021 2020 2019 Land Value $315,592 $315,592 $315,592 Building Value $202,910 $205,768 $208,626 XF Value $42,666 $43,105 $43,494 Market Value $561,168 $564.465 $567,712 Assessed Value $450,475 $444,256 $434,268 Benefits Information Benefit Type 2021 2020 2019 Save Our Homes Assessment $110.693 $120,209 $133,444 Cap Reduction Homestead Exemption $25,000 $25,000 $25,000 Second Exemption $25,000 $25,000 $25,000 Homestead Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 S1 /2 OF LOT 4 & ALL OF LOT 5 BLK 23 LOT SIZE 81,000 X 130 Generated On: 5/23/2022 Taxable Value Information 2021 2020 2019 County Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $400,4751 $394,256 $384,268 School Board Exemption Value 1 $25,000 $25,000 $25,000 Taxable Value 1 $425,475 $419,256 $409,268 City Exemption Value 1 $50,000 $50,0001 $50,000 Taxable Value 1 $400,475 $394,266 $384,268 Regional Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $400,475 $394,256 $384,268 11 Sales Information Previous OR Book - Price Qualification Description Sale Page 28260 08/31I2012 $420,000 Qual by exam of deed 3956 27759- Corrective, tax or QCD; min 07106/2011 $100 4395 consideration 21244 05/01/2003 $290,000 Sales which are qualified 3801 14316- Sales which are disqualified as a result 10I01/1989 $0 1210 of examination of the deed The Offioe of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability. see full disclaimer and User Agreement at htto:/A+ .miamidade.00v/info/disclaimer.asD 4gps://www.miamidade.gov/Apps/PA/propertysearch/ 5/23/2022 Miami Shores Village Building Department SURVEY AFFIDAVIT STATE OF (FLORIDA) COUNTY OF (DADE) 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Ra_� The undersigned Affiant, l� a' �-� , does hereby attest that (Property owner) The attached survey, performed by 310JN c&> Su \re-�:j o �- (Name of surveyor's company) For address: Z 1 C' N E Z y1l AV e Performed on 1 C41 ° 11 to (date of survey) is an accurate representation of the existing conditions and locations of all structures on the property as of this date. The purpose of this Affidavit is to induce Miami Shores Village to issue a building permit for the property without first providing a survey less than seven (7) years old old. The Affiant, as property owner, further agrees to remove or obtain permits for any structures which now may exist on the property which are not permitted or which may violate zoning or building code regulations. The Affiant further understands that the existence of any such structures may affect final inspections as applicable to this or other permits. Furt r, ff nt say eth na ht. Prop y Owner Signature Property Owner Print Name SW RN TO AND SUBSCRIBED before me this 2 3 day of %UkQ--N Affiant is personally known to me, ✓produced as identification. Revised on 5122/2009/ Revised on 6/12/09 Vivienne Yao A, Comm.:HH 222410 . _ Expires: Jan. 31, 2026 Notary Public. state of Florida I�N1111 --o Notary 1!e •� \ ly � � ` RAfAiNOfft BLOO:4+1 13o.D(r ( R 6 M) C G Yl �n cG �Y ]'C.BS WAll O'I ! N LOT J ..LF85N21:..____.—. BLOO:9 p $ ^- � ISAa 20AV qq i JIM !. TNat SM _— ffiim d R ms. iemo U.ta 3xor 6 N31 IS 113E 313Q POOL fly R1KP •� e Y tars usa w BI.aCK n um � I M RAIL 130.0W (R&M) a .:.:. .. .. .. .. .' :: :....::. .......... 1��m1L.01.madfllY:NMF.OhpMHnlU4Nra0.•PIC}GEYING.O�8d4WNYrta, WPYBICPW�GUMC I•\d00MW11COY1Yax1•BR(?INPYRV•WPA Y•1e•na•MYL•,W.•YAppallMf.fB•45WdR_6G\FNIa•'aRV\ ,z+rwn woo¢ m•e.moela rw. AY•41E,11 w NY N••NNMd •Ail•Wr, rw.mrtn u6 •. o,umA rre•I.xx 1 Y..e)aAm wnaeoamo�w•eomaort.muwmvnatw+,+s\w;wwu • mcsan mrwm,amaosw.o. an•rarer.F.+a2areacar•vlaowrwea\ve+uwalvAne\ •,,, ELEVATION BASED ON LOC.3 I7V,alIDlaap3a pyppSfFDM1111 p/ iy5CM,•YL[n.F.YfMr.YaoL CBtN ELV rypa WHOGItt BUNVCY ..SUHVEYORlSSEALGN,aNPE RE Ia NOT INaIAANGE 4) lE4LL aEBGtP110N RiOV�EE1EM: !) B'+!w)"° FYtvak b\aS1ERGRQUHa ENCxOAGMENna HOT LOW811 W EtEAN s ME BASF ON NATEODETC VFAlMJ1L OATUN OF 1929.i) ohNERSHIV OF rENCES ARE UIMHOWl O THERE Momtot \B a 1ToARYORSLIMIUNNFfY. aI AUMORRY RilOnl 10 ANY aE$Icx YAP( FOR aUItD2OHINoECmi0.� :p;jb •,m • • •lbiK'tl wkhonwtklm mBvn[aPiaY •IyliuB lmrtY arpudc. Pas N. NUM2 HEGl41EREDtANDSURN . aE&na FWm $HOPAI AHE AB->: M TO Me ASCUAW VALUE nX ♦✓JD PB_-PA(E BBYTEOFF ,I`S( E-2Z-SO-All :• :• -suolleln6aj pue salnj Atuno:) pue a a5 ' apad lie LI11M wuepdwo:) o7 yoa[gnS Z 4da(3 6u!plln9 •�• leO 1da0 6ulUOZ : ... dJe(] au w edap 6u!pl1II!A sa1o4we5 IW ' .. .: ..�.. LOCATION SKETCH SCALE!NTS NS• Ow NIR04 N N 1 0 N 7 l 3 , W a d�d FFF���� u♦ • V. Proo¢av, Address: 9210 N.E. Y°AYe,. Miami Shore�RjSB.'. •••• •••, Lend Desalotbn: tat Sand the Sooty 33 feet of Lot Al, Bork 23.MIAIN SHORESSECtION ONE AMENDED, a=tding to the Plat thereof, as recorded in Plat Book 10, at Page 70, of the Publk Records of Miami. Dade Caamy, Florida. BLANGO SURVEYORS INC. P glmm• IaMaWgon • P4vncro • LB 900at058 S8! BORTH 6NORE OWVE MAN BEACH, FL 33141 ass-12am taoB Nacm�rvovoJ�yol'a^rao FB:: (]si)Bsi7Bi0 X ° L °�_ 9/11/09 N/A AdOO A113 Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CHAIN LINK FENCE DESIGN DETAIL (ACCORDING TO THE F.B.C. SECTION R4408.11) TABLE R4408.11 CHAIN LINK FENCE MINIMUM REQUEREMENTS Fence Terminal Post Line Post Dimensions Terminal Post Line Post Concrete Height (ft) Dimensions (in inches) Concrete Foundation Size (in inches) (o.d. X wall thickness) Foundation Size (diameter X depth) (o.d. X wall thickness) (diameter X depth) (in inches) • in inches 23lS x 0.042 1 518 x 0.047 10 x 24 8 x 24 ..Over 4,t 2 3 x 0.042 1 7/8 x 0.055 10 x 24 8 x 24 .: .: .... For !l;1iVh=25.4Up.., ..... NOTES! ' ..:.. 1.. ' '.,%. This table is applicable only to f es with unrestricted airflow. 2, %Aric: 12''byauge minimum Black r Green. • : 3. • Tension beAdt,s�:�Jse one less than a height of the fence in feet evenly spaced. ...... 4. Fabric Tiesr 6?. minimum the same gauge of the fabric. • 5! - Fabric Tie.SR9&W on the Top Rail: Five ties between posts evenly spaced. ...... 6' 0 ?4ric Tie Spacing on Line Posts: One less than height of the fence in feet, evenly spaced. 7 `Dither top rail or top tension wire shall be used. 8. Braces must be used at Terminal Posts if top tension wire is used instead of Top Rail. 9. Post Spacing: 10 foot (3m) on center maximum. 10. Post shall be embedded to within 6 inches (152 mm) from bottom of the foundation. 11. In order to follow the contour of the land, the bottom of the fence may clear the contour of the ground by up to 5 inch (127 mm) without increasing table values to the next higher limit. NOTICE TO PROPERTIES WITH POOLS: If the fence is to meet the criteria as a pool barrier, the fence shall not be climbable and all rails must be placed facing the inside of the property. Pedestrian gates shall have self -closing and latching devices installed at the minimum of 54" above ground. For further details see Section 1144011.7.11 of FBC. CONCURRED Created on 5/22/2009 MLDV;0522/2015