Loading...
PL-06-22-1387Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address 442 NE 103RD ST, Miami Shores, FL 33238 Contacts Permit NO.: PL-06-22-1387 Permit Type: Plumbing- Residential Work Classification: New Permit Status: Approved Issue Date:06/07/2022 Expiration: 12/07/2022 Parcel Number 1132060170740 MUHAMMAD KANJI Owner AROUND THE CLOCK GAS SERVICE Contractor 442 NE 103 ST, MIAMI SHORES, FL 33138 AMAURY GONZALEZ 13117 NW 107 AVE 17, HIALEAH, FL 33018 Business:3052313632 sales@aroundtheclockgas.com Description: NATURAL GAS LINE AND CONNECTIONS TO A Valuation: $ 7,290.00 Ins ection Requests: TANKLES WATER HEATER, GENERATOR AND FUTURE BBQ Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $4.80 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $1.60 Permit Fee (Manual) $255.15 Scanning Fee $9.00 Technology Fee (Manual) $6.38 Total: $330.93 Payments Date Paid Amt Paid Total Fees $330.93 Credit Card 06/07/2022 $280.93 Credit Card 06/01/2022 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating n an zoning. Futhermore,authorize the above named contractor to do the work stated. �iIc! C) 6a,Z Authorized Signature: Owner / Applicant / Contractor / Agent Date June 07, 2022 Page 2 of 2 Miami Shores Village SCE,ptECE, IVED Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 $Y: INSPECTION LINE PHONE NUMBER: (305) 762-4949 " (�FBC 20 (,� BUILDING Master Permit No. YL- U�zz- � PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL [-]PLUMBING ❑ MECHANICAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP 1y/ CONTRACTOR DRAWINGS JOB ADDRESS: 1 I � Iy a 5sill e�-e City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: n 14-- 6 �9' t%0 Is the Building Historically Designated: Yes NO 'qZ- Occupancy Type: Load: Construction Type: _I Flood r Zone: BFE: FIFE: OWNER: Name (Fee Simple Titleholder): V ��ya t-k f'N A �\ �Fl J i ' Phone#:^�? V A7 I -c? G1 :7 Address: City: ►'l 14 y i C P6 ��' S State: ' C zip: 733 1 3 e Tenant/Lessee Name: Phone#: Email: II CONTRACTOR: Company Name: 4 /m; . A 7 � � c (zt c k 6,4-f Phone#: 3 Gs"-d 1? 0 Address: /3)/77n !! /N'_' / D- mily1 `P /--f /-�- /T,'4 4Al Email: F A4 e-5 F6 All C :� � `� � P C I G C ,Z` (� �� �C� r-1 Qualifier Name: (--) rn A - 4/'P Z Phone#: -7 -36-7 '7S Q State Certification or Registration #: 3 % Certificate of Competency #: DESIGNER: Archite Engineer: n Phone#: Address: c = 1' City: State: _Zip: Value of Work for this Permit: $I i l d Square/Linear Footage of Work: Type of Work: ❑ Adndiitio��n ❑ Alteration // XNew ❑ Repair/Replace ❑ Demolition Description of Work:: r4 v A � y l>4 S/ \ k � -e A � A ( O � � -1 P c � i 0 �\ . A- 4�e_ %4 a*- e, 6ca 1 P"1 f;-lCj, /) j f J it Specify color of color\ thru tile: Submittal Fee$ PermimitFee$ >'I✓ CCF$ -1 CO/CC$ Scanning Fee $ V 2U r'► DCA Fee $ U U D�BnPlRI$ � ' V 7� Notary: Technology Fee $�p • ") 1 Training/Education Fee $ U/V Double Fee $. Structural Reviews (Revised04/05/2022) P&Z Review $ Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State M. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charge C Signature OWNER or AGENT The foregoing instrument was acknowledged before me this \ day of D J "`k 20 D 4 . by i t V y A )�M 17who is personally known to me or who has produced K15zo - 5 9 1 - IZ-1 33-AS identification and who did take an oath. NOTARY PUBLIC: Edwin L. Sliver p dyNotary Public to State of Florida Sign: �-l'A "=Comm#HH074688 Print: �A w ,, S \ \ � � CE 1 Expires 1/22/2025 Seal: APPROVED BY (Revised04/05/2022) d. Signature CONTRACTOR The foregoing instrument was acknowledged before me this Q 1 day of 'O 2 20 g) �- , by H . q✓:� l 6 -✓i s411e L who is personally known to me or who has produced identification and who did take an oath. as NOTARY PUBLIC: Edwin L, Sllver n Notary Public `EState of Florida Sign: ( y ` Comm# HH074688 Print: I ..-� -� t IJ P'"'`d4FE e Expires 1/22/2025 Seal: Plans Examiner Zoning Structural Review Clerk Lonaest Run: 72 Feet. Total Load: 616,000 BTU's. Tvoe of Gas: Natural Gas. Materials: Galvanized Pipe: CSST Tubing Chart: Poly Plastic Pipe Chart: New Outlet (S) 3 New Conqection (S) 2 100,000 BTU's. New 1/2" Outlet. CITY '�MllrllOPY 336,000 BTU's. 3/4" Outlet. 3/4" Shut Off Valve. Sediment Trap. Newt -PSI Pietro Requlator. 314" IPS IAnodelessl Risers, 2' Around The Clock Gas Services Installation done in accordance witly BC 2020, LPGO17356 NFPA 54 & 58 regulations as well Aoalllocal cod V'11151a' No / u61ic` 2 13117 N.W. 107th Ave Unit # 17 5/31/2022 14:23 1aLeofFlorida Hialeah Gardens, Florida 33018 Amaury Gonzalez Phone: 305 231-3632 /Fax: 305 231-4180 Job Address: 442 NE Street. "-` s Florida Buildinq 2020 Code - Gas Fuel Tables. Chart # 402.4 (5) (2 PSI) (Galvanized Pipe). Chart # 402.4 (18) (2 PSI) (CSST Tubinq). Chart # 402.4 (22) (2 PSI) (Poly Plastic Pipe). Rinnai(RL75E-N / Outdo 2-PSI Gas System. N O R T H 336,000 BTU's. 3/4" Outlet. Around The Clock Gas Services Installation done in accordance with FBC 2020, ro��� �o Edwin L. sewer LPG017356 NFPA 54 & 58 regulations as we s all -local codes < n Nota`fy �(Q!?2 13117 N.W. 107th Ave Unit # 17 5/31/2022 14:23 o jsta -of Florida Hialeah Gardens, Florida 33018 Amaury Gonzalez 7 ?Comm#HH074688 Phone: 305 231-3632 1 Fax: 305 231-4180 Job Address: 442 NE"103o rA Street. oorEP�f z2 zozs FOR INDCOR APPLICATIONS ONLY RL751..................... REU-VC2528FFUD-US REU-VC2528FFUD-US(A) Rlae941................... REU-VC2737FFUD-US R134i..................... REU-VC2837FFUD-US OUTDOOR APPLICATIONS ONLY .................... REU-VC2528WD-US REU-VC2528WD-US(A) .................. REU-VC2837WD-US C 0 US CH Low Lead Content SANITATION NSF/ANSI 372 Direct Vent Tankless Water Heater Installation and - Operation Manual �ESIBN ` = VED cFerit�Eo ® PF4�� ANS Z21.10.3 • CSA 4.3 BY: READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER. This manual provides information on the installation, operation, and maintenance of the water heater. For proper operation and safety, it is important to follow the instructions and adhere to the safety precautions. A licensed professional must install the water heater according to the exact instructions on pages 4-30. The consumer must read the entire manual to properly operate the water heater and to have regular maintenance performed. If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. 11 — Do not store ar use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO 1F-,f4DU SA1fELL,GAS • Do not try to light any appliance. ` Do not touch any ekKuical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a licensed professional. This entire manual must be left for the consumer. The consumer must read and refer to this manual for proper operation and to maintain the water heater. u307-0710X04(00) 060 00012 34135 5 Terminal Clearances For indoor models, you must install a vent termination to bring in combustion air and expel exhaust. TERMINATION Inside ©AIR SUPPLY INLET me d G �V VENTTERMINAL 7-clearance in !� Ref. A also V applies to ®AREA WHERE TERMINAL IS anticipated I s H' NOT PERMITTTED I snow line ? v FZECEIVE £�`, .`, SNOW L �C— l dlosed }� Y V � V�Operablei M dozed 3 ' �;cyi perabl - a—� " i Regulator ventoutlet Direct Vent (Indoor Unit) Cana �illld' Ref Canadian Installations USlnstailatiens Description (CSA B149.1) (ANSI Z223.1 / NFPA 54) (CSA B149.1) A Clearance above grade, veranda, porch, deck or balcony 12 Inches (30 cm) 12 inches (30 cm) 12 inches (30 cm) 12 inches (30 cm) 6in(15 cm) for appliances 510,000 Btuh(3 Tta ^ "`=);below or to B Clearance to window' or door That maybe opened 36 Inches(91 cm) 12 inches (30 cm) BtukW), 12in(3d cm) for 0Btuh(30kW,000 and 5 (30 kW), 36 in ling; 1ft130C aft (91 m forkVV) ces>l0 ,00 (91 cm) for appllances>100,000 Btuh (30 kW) mm) above opening C Clearance to permanently closed window Verica: clearance to ventilated soffit, located above the D I terming, within a horaontal distance of 2 feet (61 cm) i from a- center line of the terminal £ Cleaaxs a uoverdiated soffit F was W outside comer • ' 6' (lBfdlQiD nsice corner ' H Clearance to each side ofcenter line extended above meteriregutamr assen»'f Above a regulator within 3 it (91 cm) horizontally of the Above a regulator within 3 It (92 cm) I Clearance to service regulator reht outie: I vertical center line of horizontally of the vertical center line of the , the regulator vent regulator vent outlet to a maximum vertical outet :c a maximum distance of 15 It I4.5 mj vertical distance of 15 p ja.5 cal I 6in(15 cm) for appliances S 10,0000tuh(3 4 ft(1.2 m) below or to 1 Clearance to nonmechanical air supply inlet w btailding or 36mches(91 cm) 12 inches (30 cm) kW), 12 in (30 cm) for appliances ,10,000 side of opening; l ft(300 the combustion air Inlet to any other appliance Soul, (3 M4) and 5 300,000 South (30 kW), 36 In (91=I for appliances>100,00) Stuh(30 kW) mm) above opening 3 feet(91 cm) above if 3 feet(91 cm) above if K Clearance to a mechanical air supply inlet 6feet (1.83 m) within 10 feet (3 m) 6feet (1.83 m) within 10 feet (3 m) horizontally horizontally t Clearance above Paved sidewalk or paved driveway 7 feet (2.13 m) C ]feet (2.13 m) m located an public property 1A Clearance under veranda, porch, deck, or balcony 12 inches (30 cm) 9 12 inches (30 cm) 0 (1] A vent shall not terminate directly above a sidewalk or paved driveway that is + For clearances not specified in ANSI Z223.1/NFPA 54, clearances are in located between two single family dwellings and serves both dwellings. accordance with local installation codes and the requirements of the gas supplier. [2] Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of Clearance to opposite wall is 24 inches (60 cm). two sides beneath the floor. VC Series Manual 7 • Type of Appliance Rinnai Model Number Minimum/Maximum Gas Rate (Input) Electrical Electrical Consumption Ignition System Hot Water Capacity Temperature Temperature (without remote) Installation Energy Factor Service Connections Isolation & Pressure Relief Valves Included Water Flow Control Minimum/Maximum Water Supply Pressure • Temperature controlled, continuous flow, gas hot water system • Certified for installation in manufactured (mobile) homes • Forced combustion / Direct vent • Energy Star qualified REU-VC2528FFUD-US 10,300 - 180,000 BTU/h Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts Normal: 76 w Standby: 2 w Anti -frost protection: 120 w Direct electronic ignition Minimum flow rate: 0.26 GPM Minimum activation flow rate: 0.4 GPM Maximum flow rate: 7.5 GPM 98' - 120' F (factory default) Maximum temperature is selectable at 1200 F or at 1400 F; 98' - 1600 F available with the MCC-91-2 controller for commercial and hydronic applications 1200 F (factory default) or 1400 F Indoor only Natural Gas: 0.82 Propane: 0.82 Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT Heavy duty forged brass Webstone Isolator valves EXP E2, certified to NSF/ANSI 61-8 for potable water Water flow sensor, electronic water control device and fixed by-pass 20 - 150 PSI (recommended 30-80 PSI for maximum performance) 0 25 50 75 100 125 150 delta T - Temperature Rise (OF) © 2012 Rinnai Corporation RVsi VC SF 3/2012 g� � p `� Z `°® NSF.! N N. Water Temperature Control Simulation feed forward and feedback Controller MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1 US (optional) Bathroom controller: BC-100V-1 US (optional) qhA�vE CC-91-2US (optional; for hydronic and commercial applications) Controller Cable on -polarized two -core cable, minimup 22 AWG Safety Devices e Flame failure - Flame Rod !,Remaining flame (OHS) • Boiling protection • :'.7'hermal fuse Combustion fan rpm check Automatic frost protection • Over current - glass fuse Clearances from Combustibles (suitable for closet, attic, and crawl space installations) Clearances from Non -combustibles Min. / Max. Gas Supply Pressure (sea level) Manifold Gas Pressure (inches W.C.) NOx • Top of heater - 6 inches • lock of heater - 0 inches • Front of heater - 6 inches • Ground / bottom - 12 inches • Sides of heater - 2 inches • From vent pipe - 0 inches • Top of heater - 2 inches • Back of heater - 0 inches • Front of heater - 6 inches • Ground / bottom - 12 inches • Sides of heater - 1/2 inch • From vent pipe - 0 inches Natural Gas: min 5" W.C. max 10.5" W.C. Propane Gas: min 8" W.C. max 13.5" W.C. Natural Gas: high fire 2.5' W.C. low fire 0.61" W.C. Propane Gas: high fire 3.9" W.C. low fire 0.87" W.C. Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Limited Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for Warranty commercial; All other Darts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an on -demand recirculation system is not incorporated.) Refer to the manuai for complete warranty intormation. • r_14.04 (356.6) WEIGHT: 45.6 Ib (20.7 9.27 (235.5) kg) COLD,9'ATFF RUT 0.4-1.8 (10-45) Variable I rr 5.05 (128.1) m I m N R I 1 I I I C E F G L—D m N rn r O' O •O 0 0 Q DIMEN- SION Inches (mm) DIMEN- SION Inches (mm) A (GAS) 1.31 (33.2) D 4.33 (110) A (COLD) 1.93 (49) E 2.89 (73.3) A (HOT) 1.35 (34.4) F 1.85 (47) B Rinnai Corporation • 103 International Drive •Peachtree City, GA 30269 •Toll -Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us