Loading...
RF-07-22-1763Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Issue Date: 08/04/2022 Parcel Number 444 NE 102ND ST, Miami Shores, FL 33138 1132060170580 Contacts Permit No.: RF-07-22-1763 Permit Type: Roof Work Classification: Flat Permit Status: Approved Expiration: 02/06/2023 FELIPE SAES AZENHA OLGA E RAMOS Owner I ADDERLY DEVELOPMENT INC Contractor 444 NE 102 5T, MIAMI SHORES, FL 33138 TODD R ADDERLY 8255 W SUNRISE BLVD 119, PLANTATION, FL 33: Business: 9544454078 adderlydev@yahoo com Inspection Requests Description: RE -ROOF FLAT Valuation: $ 8,000.00 305-762 4949 - Total Sq Feet: 1,800.00 _..:: Fees Amount Application Fee - Other $50.00 CCF $4.80 DBPR Fee $4.13 DCA Fee $2.75 Education Surcharge $1.60 Roofing Fee $225.00 Scanning Fee (Manual) $9.00 Technology Fee $6.88 Total: $304.16 Payments Date Paid Amt Paid Total Fees $304.16 Credit Card 08/04/2022 $254.16 Credit Card 07/12/2022 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction a0d2aning. Futhennore, I authorize the above named contractor to d ' e_work sta ed. `i. CA,_I� �4, C/� F- �J - La L z Authorized gignature: Owner / Applicant / Contractor / Agent Date August 04, 2022 Page 2 of 2 RE�cF:i VE:D Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 Im FBC 201b 3 BUILDING Master Permit No. W ''�V PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC Q ROOFING ❑ REVISION ❑ EXTENSION [—]RENEWAL XU 2 2022 BY: ❑PLUMBING [:]MECHANICAL ❑PUBLIC WORKS [:]CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 444 NE 102 STMiami Shores, FL 33138-2453 City: Miami Shores County: Miami Dade Zip: Folio/Parcelp:11-3206-017-0580 Is the Building Historically Designated: Yes NO Occupancy Type:J-EtL— Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): FELIPE SAES AZENHAOLGA E RAMOS Address:444 NE 102 ST Miami Shores, FL 33138-2453 City: 1 , I L C Tenant/Lessee Email: State: CONTRACTOR: Company Name: ADDERLY DEVELOPMENT INC Address: 5079 N DIXIE HWY - 258 City: OAKLAND PK State: FL Qualifier Name: TODD ADDERLY Phone State Certification or Registration k: CCC 1327886 Certificate of Competency p: DESIGNER: Architect/.Eneineer: Phone f - Value of Work for this Permit: $ 5100 Type of Work: ❑ Addition ❑ Alteration Description of Work: RE ROOF FLAT Specify colorsofcolor l thru tile: � t1 Submittal Fee $�Permit Fee $ Scanning Fee $ "/�I / Radon Fee $ Technology Fee Trying, Structural Reviews $ Np: 33/3 954 445 4078 ,ip: 33334 954 445 4078 _City: State: cZip: ' Square/Linear Footage of Work: d 0 a ❑ New jef Repair/Replace ❑ Demolition CO/Cc $ le Fee $ Bond $ TOTAL FEE NOW DUE $ Q's:q • I (Revised02/24/2014) rrn- FVCI SS�aA Bonding Company's Name (if applicable) Bonding Company's City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged, \ Signature OWNER or AGENT The foregoing instrument was acknowledged before me this day oof `� .20 by h0%(v o is personay wn to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: 6 Sign: ,"G"' CHIQUITA POSTELL Print:°o`°" 'E Commission N GG 338980 Seal: %° '� M Commission Expires ��� Y p11 July 11, 2023 L � Signature— COlKTRACrOR The foregoing instrument was acknowledged before me this 2 day of MAY 20 22 by b -ev who is personally known to me or who has produced t--� / "-7 as identification and who did take an oath NOTARY Print: Shantel Tdnaye Rorie Notary FUNIc Seal: State of Florida Commission My ®art rule I n No, Q0 094254D24 r APPROVED BY 2 Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33133 305-795-2204 www.msvfl.gov OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: —2 -7—;. Z 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: rt. h Z -e l,' Vl BI Property Address: 4- i l U n If)? S j Roofing Permit Number: Dear Building Official: I TODD ADDERLY certify that I am not required to retrofit the roof to wall connections of my building because: (4PThe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature Print Nam State of Florida, Miami Dade County The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me is 74;� f-If 20Z,: V''� CHIQUITA POSTELL p UB(r= Notary Public -State of Floric Commission N Gr. 33898( Notary Public, State of Florida at Large °"`' My Commission es n u." July 11, 2023 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. For Forms and Applications click here: http://bidg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia miShoresVillage pev0 i 14 20=i 7wn:e, affidavit o e eruption Poge 1 of 1 OFFICE Of THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-017-0580 Property Address: 444 NE 102 ST Miami Shores, FL 33138.2453 Owner FELIPE SAES AZENHA OLGA E RAMOS Mailing Address 444 NE 102 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL- SINGLE FAMILY: 1 UNIT Beds I Baths I Half 311 / 1 Floors 2 Living Units 1 Actual Area 2,044 Sq.Ft Living Area 2.044 Sq.Ft Adjusted Area 1.896 Sq.Ft Lot Size 7,475 Sq.Ft Year Built Multiple (See Building Info.) Assessment Information Year 020 2019 Land Value ,663 $224.340 Building Value ,418 $185,596 XF Value W$168,802$166,4721 870 $885 Market Value ,951 $410,821 Assessed Value ,472 $162,730 Benefits Information Benefit Type 2021 2020 2019 Save Our Homes Cap Assessment Reduction $205.371 $259,479 $248,091 Homestead Exemption $25.000 $25,000 $25.000 Second Homestead Exemption $25.000 $25.000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 6 53 42 PS 15-14 AMD PL OF MIAMI SHORES SEC 4 W 1/2 OF LOT 6 & E40FT OF LOT 7 BLK 91 LOT SIZE IRREGULAR Generated On : 5/2/2022 Taxable Value Information 2021 2020 2019 County Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $118,802 $116,472 $112,730 School Board Exemption Value 1 $25,000 $25,000 $25,000 Taxable Value 1 $143,802 $141.472 $137,730 city Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $118,802 $116,472 $112,730 Regional Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $118,802 $116,472 $112,730 Sales Information Previous Sale Price OR Book -Page Ouslifioation Description 03/08/2021 1 $645,000 32409-1816 Qual by exam of deed 03/01/1989 1 $91,000 14057-3891 Sales which are qualified The Once of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Properly Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://w.miamidade.govfnfo/disclaimer.asp Florida Building Code 7th Edition (2020) High Velocity Hurricane Zone Uniform Roofing Application Form for Miami -Dada a� , ✓ l . Section A (General Information) Master Permit Number: Contractor's Name: A d G -C Process Number: L Job Address: L-1 LLc Iyl L b 2 1 -/ ROOF CATEGORY * Low Slope ❑ Mechanically Fastened Tile ❑ Mortar / Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/ Shingles ❑ Wood Shingles / Shakes ROOF TYPE ❑ New Roof ❑ Repair ❑ Maintenance A Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Lowy Slope f�oof Area (ftZ) Steep Sloped Roof Area (ft2) Total ft2' Are there gas vents on the roof? 0 Yes 1) No If Yes what type? O Natural LPX Is there an existing roof top Solar System? 0 Yes ® No If yes will it be reinstalled? 0 Yes 0 No Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ROOF ZONE WIDTH = 0.6h Where h=mean height h=13' ROOF ZONE WIDTH=0.6X13' =8' CORNER DINEMSIONS 3Bhx0.2h BUT NEITHER DIMENSION CAN BE LESS THAN 3' BY DEFAULT 0.6h= 6' 0.2h=(2.6')= DEFAULT TO 3" CITY z 9 OPti Miami Shores Village uilding Zoning Dept. _ Darl Building Dept. Dati ubject to comp Ith a State and County rules and re ermit# 3 t Florida Building Code 7th Edition (2020) High Velocity Hurricane tone Uniform Roofing Application Form for Miami -Dade County Section C (Low Sloped Roof Systems) Fill in Specific Roof Assembly Components and Identify manufacturer (if a component is not used, identify as "NA") System Manufacturer: GAF Product Approval # 18-0919.07 Design Wind Pressures, from RAS 128 or Calculations: Zone 1': 37 Zone 1: 64 Zone 2: 84 Zone 3: 115 Max. Design Pressure, from the specific product approval system: -52.5 Deck Type: pLWOOD Gauge / Thickness: MIN 5/8" Slope: 2:12 Anchor/ Base Sheet & No. of Ply(s): 1 PLY 75# BASE Anchor/ Base Sheet Fastener/ Bonding Material: 1-1/4" 11 GA R/S NAILS & 1-5/8" TINCAPS Insulation Base Layer: HD FIBERBOARD Base Insulation Size and Thickness: 1/2"X4'X4' Base Insulation Fastener/ Bonding Material: HOT ASPHALT Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A Top Insulation Fastener/Bonding Material: N/A Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/ Bonding Material: N/A N/A Ply Sheet(s) and No. of Ply(s): 3: PLIES OF PLY 4 FELT Ply Sheet Fastener/ Bonding Material: HOT ASPHALT Top Ply Fastener/ Bonding Material: HOT ASPHALT Surfacing: N/A Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1' 9 " cc @ Laps, # Rows 2 @ 9 " cc Zone 1 _ 7 _ " cc @ Laps, # Rows _ 2_ @_ " cc Zone 2 r " cc @ Laps # Rows 2 @ r " cc Zone 3 _5_ " cc @ Laps, # Rows 3 @ 5 'cc Number of Fasteners Per insulation Board Zone 1': N/A Zone1: N/A Zone 2: N/A Zone 3: N/A illustrated Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufactures Details that Comply with RAS 111 and Chapter 16. FT_0. - - - Parape GAF MINERAL SURFACED CAP SHE Height 10"&12" STRIPS OF PLY 4 Fli3X3I GA GALV. DRIP EDGE 3 PLIES OF GAF PLY 4 FELT PLY OF 750 CAASS UASE -A 13 FT. MIN. SS' PLYWOOD Mean - - Roof Height 1P HD WOOD FIBERBOAR Top Ply: GAF MINERAL SURFACED CAP SHEET y 1X6 PT WOOD NAILER 2020 FBC HVHZ COMMON PRESCRIPTIVE ANCHOR/BASE SHEETATTACHMENT PATTERNS TABLE The 2020 RAS-1172andard Requirements for the Mechanical AKachment of Anchor or Base Sheets M Subsbotes and the 2020 RAS-128 Standard Procedures far Determining Appikable Wind Design Pressures for Low Siope Roofs, were used in developing this table. The prescriptive attachment patterns in this table are for use on Risk Category II Mdings with plywood substrates using exposure Category C, per ASCE 7-16. The buildings roof slope shall be no greater than 1.5/12 ft. A Miami -Dade County (MDC) Notice of Acceptance (NOA) Is required, which Is limited to roof systems with a maximum design pressure of -52.5 psf. General limitation ill Is also required, which allows extrapolation of additional fasteners in roof pressures zones P1, P2, P3. The maximum -52.5 psf MDC NOA design pressure shall be Z than the job site PV wind uplift pressure per the listed roof mean height in RAS-128, in order to use the prescriptive attachment patterns listed In this table. Roof Mean Height Umited to a design pressure of I -52.5 psf In the applicable MDC NOA I Side lap fastener spacingIn Number of center raves Center rows fastener spacing n/R MD[ ePermictlno for Contractors Firestone Patter ' 1015 ft 2 . - 6'QIc. Pl%P1 spaft' Reid Exterior Pi 4" a/c 2 e a/c 4" a/c @ la ws & 2 ram 4" a/c Perimeter P2 5' a/c 3 5" a/c P2a P3 spadho ' Comer P3 4' a/c 4 4" a/c 4' a/c @ laps & 4 rows 4' a/c 16-20 ft Reld htterfocPi" Noa :- 6` C '.: - ' 2 _. (G'.o/c` - P1-P1 ' Field Exterior Pi 4" o% 2 4" a/c 4" a/c 0 laps & 2 rows 4' a/c Perimeter P2 4' o c 3 4" a/c P2-P31spadbut Comer P3 4" a/c 4 4" a/c 4" a/c 0 laps & 4 rows 4" a/c 21-25 R 6"'a/d P1'6P2 spacing' Reid Exterior P1 4" a/c2 4" a/c 4" a/c @ la & 2 rows @ 4' a/c Perimeter P2 4" a/c 3 4" a/c P2a P3 spadng ' Comer P3 4" o% 4 4" a/c 4" a/c @ laps & 4 raves 4" o% 26-30 ft Reid Exterior P1 4- a/c2 4' a/c 4" a/c @ la ves & 2 ram 0 4' a c Perimeter P2 4" a/c 3 4" a/c P2-P3 ' Comer P3 4" 9A 5 1 4"a/c 4'a/c 0 laps &5rows 4" c GAF Pattern = P1 API spacing 16 20 ft G, - C. Field Exterior P1 6" a/c 2 6" a/c 6" a/c0 la & 2 rows 6" a/c Perimeter P2 5" o c 2 5" a/c P2- P3 ' Comer P3 5" a/c3 5" a/c 5' a/c @ laps & 3 raves S" a/c 1 21-25 ft 0A � F—W..Irttetf*W _ �: 9` ' c "_ a .... 2 _ _ r c _ P2'�1 ' Field Exterior Pi 6" a/c2 6" o/c 6" a/c @ laps & 2 rows @ 6" a/c Perimeter P2 4" a/c 2 4" a/c P2a P3 ' Comer P3 4" a/c 3 4" a/c 4" a/c@ laps & 3 raves 4' a/c 26-30 ft ' Reldlnteriar P1`' NOA. _ .. �"; ' c '.' 12. - 9Rta/c P1'-P1 E ' Reid Exterior P1 6' a/c 2 6" a/c 6" a/c @ la & 2 rows @ 6" Perimeter P2 4" a/c 2 4" a/c P2a P3 ' Comer P3 4" o/c 3 4" a/c4" a/c0 laps & 3 rows 4" a/c Johns Manville Patter' P1,� fig, 10-15 ft Reidlnterlar.Pt' OA _ ; .' _, c 2 22"_a/c Field Exterior Pi 8" a/c2 8" a/c 8" a/c @ laps & 2 rows 8" a/c Perimeter P2 6" a/c 2 6" a/c P2* P3 ' Comer P3 6" a/c 3 6" a/c 6" a/c@ laps & 3 rows 6" a/c 16-20 It Reid ittteriorPl" NOA V, C 2 12" o C P1Wn d ' Field Exterior P1 8" a/c 2 8" a/c S' a/c @ la & 2 rows 8" a/c Perimeter P2 6" a/c 2 6" a/c P2a P3 Comer P3 6" o/c 3 6" a/c 6" a/c @ laps & 3 rows 6" a/c 21-25 ft Reid pA '9" C 2 W C P116Pt ' Field Exterior Pi 7" a/c2 7" a/c 7" a/c@ la & 2 rows 0 7" a/c Perimeter P2 5" a/c 2 Sol a/c P2a P3 s ' Comer P3 5" a/c 3 5" a/c 5" o/c @laps & 3 rows 5" a/cReid 26.30 ft IMdor Pi" NOA 9' c 2 12' a/c P1�P2 ' Field Exterior Pi 7" a/c2 7" a/c 7" a/c @ laps & 2 rows ► 7" a/c Perimeter P2 5" a/c 2 S' o/c P2a P3 ' Comer P3 5" a/c 3 5" a/c 5' a/c @ laps & 3 rows 5" a/c -Ra[dlMerioiPi`• NWI _�__ _ 6/29/22, 9A0 AM TGFU.R1306 - Roofing Systems I UL Product IQ Class A, B and C Hot roofing asphalt, for use with glass felts or modified bitumen membranes. Torch applied "RUBEROIDO Heat Weld" SBS roofing membranes may be used as alternates to "RUBEROIDO Mop" SBS roofing membranes in any applicable Classification. "RUBEROIDO HW 25 Smooth" may be used as an alternate to "RUBEROIDO Mop Smooth" or "RUBEROIDO Mop Smooth 1.5". Class A 1. Deck: C-15/32 Incll e: 3 Barrier Board (Optional): — One or more layers of minim m 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDecke Roofboard" or "DensDeck® Prime Roofboard", "DensDeck® DuraGuardTM' oofboard"; or minimum 1/4-in. thick United States Gypsum Co. "SECUROCKO Roof Board" (Type FRX-G) or "SECUROCKe ( Primer (Optional): — Asphalt primer complying with ASTlN applied at 0.7 - 1.0 gal./100-ft.Z, "EverGuarde TPO Quick SI (approximately 2000-ft.2 of installed coverage per 27-lb. cai coverage to the barrier board (approximately 2000-ft2 of in Vapor Barrier (Optional): — One or more plies "GAF® SA XL40", self -adhered. Insulation: — One or more layers perlite or wood fiber or composite or perlite/urethane composite or wood fiber/pol Roof Board" (type SGMRX). 1341/1341 M, applied at a rate of 0.75 - 1.0 gal./100-ft.z GAF SA Primer ay Adhesive LV50" spray applied in full coverage to the barrier board ster) or "EverGuard® TPO Quick Spray Adhesive" spray applied in full alled coverage per 30-lb. canister). apor Retarder", "GAF SA Vapor Retarder XL" or "GAF SA Vapor Retarder fiber or polyisocyanurate or urethane or perlite/polyisocyanurate .yanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type G1 "GAFGLASO Ply I", "Tri-Ply® Ply 4", "GAFGLASe Flex Ply 6", "GAFGLAS Ply 4 M", "GAFGLAS FlexPly 6 M" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered ith hot roofing asphalt. Surfacing:— Roofing gravel applied at a minimum of 400-1 s./100-ft.2 and embedded into a flood coat of hot roofing asphalt applied at a minimum of 60-lbs./100-ft2. 2. Deck: C-15/32 - Incline: 2 Barrier Board O tiona : — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCKO Roof Board" (Type FRX-G) or "SECUROCKe Glass -Mat Roof Board" (Type SGMRX). linsulation: — ne r more layers perlite or wood f1ber br glass fiber or polyisocyanu rate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Sheet: — Three or more lies jyl2e G1 "GAFGLASO Pk4j or "Tri-Plye Ply 4" or "GAFGLASe Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. lCap S eet:—T a G3 "GAFGLASe Mineral Surfaced Ca S eet" or "Tri-Plye BUR Granule Cap Sheet" or "GAFGLASO EnergyCapTM Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. https://lq.ulprospector com/en/profile?e=148955 1/1 MIMI E MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DMSION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eoWeconomv GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1030.01 and consists of pages 1 through 27. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 1 of 27 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: BUR Material: Fiberglass Deck Time: Wood Maximum Design Pressure: -97.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description GAFGLAS® Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat. Tri-Ply' Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat. GAFGLAS® 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced F1exPly 6 Wide with fiberglass mat. GAFGLAS®#75 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Base Sheet Wide with fiberglass mat. Tri-Ply6#75 Base 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Sheet Wide with fiberglass mat. GAFGLAS® #80 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Ultima Base Sheet Wide with fiberglass mat. GAFGLAS® 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic perforated venting base Stratavent® Wide sheet reinforced with fiberglass mat. Perforated Venting Base Sheet GAFGLAS® 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic nailable venting base Stratavent®Nailable Wide sheet reinforced with fiberglass mat. Bottom side Venting Base Sheet surfaced with granules. Ruberoid® 20 39.37" (1 meter) ASTM D6163 SBS polymer -modified asphalt base or Smooth Wide anchor sheet reinforced with a fiberglass mat. Ruberoid® Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or Smooth wide anchor sheet reinforced with a polyester mat. Ruberoid® Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or anchor Smooth 1.5 wide sheet reinforced with a polyester mat. Ruberoid® Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or Plus Smooth wide anchor sheet reinforced with a polyester mat. Ruberoid® HW 25 39.37" (1 meter) ASTM D6163 Smooth surfaced torch applied SBS base or anchor Smooth wide sheet reinforced with a fiberglass mat. NOA No.:18-0919.07 M1AM4DADE CO UMNWF Expiration Date: 11/04/23 on Approval Date: 11/08/18 Page 2 of 27 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Ruberoid® HW 39.37" (1 meter) ASTM D6164 Smooth surfaced torch applied SBS base or anchor Smooth GAFGLAS® Mineral Surfaced Cap Sheet Tri-Ply® BUR Granule Cap Sheet GAFGLAS® EnergyCap= Mineral Surfaced Cap Sheet Topcoat® Surface Seal SB Topcoat® Membrane Topcoat® MB Plus wide sheet reinforced with a polyester mat. 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Wide with fiberglass mat. 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Wide with fiberglass mat. 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Wide with fiberglass mat. Cap sheet is factory coated with TOPCOAT® EnergyCote' Elastomeric Coating. 5 or 55 gallons ASTM. D6083 Solvent -based thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. 1, 5 or 55 gallons ASTM D6083 Water based elastomeric coating 5 or 55 gallons Topcoat® FireOui' 5 or 55 gallons Fire Barrier Coating VersaShield® Fire- 12" x 100' rolls Resistant Roof Deck Protection VersaShield® Solo"'` 42" roll wide,100 Fire -Resistant Slip ft. Sheet Proprietary Water based, low VOC primer designed to block asphalt bleed -through. Proprietary Low VOC, water based fire barrier coating. ASTM D226 Non -asphaltic, fiberglass reinforced underlayment and/or fire barrier ASTM D146, D8289 D4869, D6757 Topcoat® 1, 5 gallons or TAS 139 F1exSea17 1 qt. tube Non -asphaltic, fire resistant fiberglass underlayment Solvent -based elastomeric sealant. NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 3 of 27 APPROVED INSULATIONS: TABLE 2 Manufacturer Product Name Product Description (With Current NOA) EnergyGuard' Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard' Tapered Polyisocyanurate foam insulation GAF Polyiso Insulation EnergyGuard' Ultra Polyiso Glass -faced polyisocyanurate foam insulation GAF Insulation EnergyGuard' RA Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard" ' RA Composite Polyisocyanurate foam insulation with high GAF Polyiso Insulation density fiberboard or permalite EnergyGuardd' RH Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard' RH Tapered Polyisocyanurate foam insulation GAF Polyiso Insulation EnergyGuard' RN Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard' Perlite Roof Perlite insulation board GAF Insulation EnergyGuard' Perlite Recover Perlite recover board GAF Board Securock® Gypsum -Fiber Roof Gypsum board United States Gypsum Corp. Board Securock® Glass -Mat Roof Glass faced gypsum board United States Gypsum Corp. Board StructodeO High Density Fiber High density fiberboard Blue Ridge Fiberboard, Inc. Board Roof Insulation DensDeck® Prime Roof Board Gypsum board Georgia-Pacific Gypsum LLC DensDeck® Roof Board Gypsum board Georgia-Pacific Gypsum LLC NOA No.:18-0919.07 MLAM®UNW Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 4 of 27 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOM 1. Drill-Tec'` #12 Fastener Phillips head, modified #12 x 8" max. GAF buttress thread, pinch point, length, #3 carbon steel fastener for use Phillips head. in steel or wood decks. With CR-10 coating. Available with a pinch point or drill point. 2. Drill-Tec"` #14 Fastener Truss head, self -drilling, #14 x 16" GAF pinch point, high thread max. length, fastener for use in steel, wood #3 Phillips or concrete decks. head. 3. Drill-Tec"' ASAP 3S Drill-Tec"` #12 Fastener with See GAF Drill -Ted" 3" Standard Steel components Plate. 4. Drill-Tec` 3" Steel Plate Round Galvalume® steel 3" Round GAF stress plate with reinforcing ribs and recessed for use with Drill-Tec"' fasteners. 5. Drill-Tec"' 3" Standard Steel Galvalume® coated steel 3" Round GAF Plate stress plate for use with approved Drill-Tec''` fasteners. 6. Drill-Tec"' AccuTrae Flat A2-SS aluminized steel plate 3" square; GAF Plate for use with Drill -Ted''' .017" thick fasteners. 7. Drill -Ted''` AccuTrac® Galvalume® steel plate with 3" square; GAF Recessed Plate recess for use with Drill- .017" thick Tee fasteners. 8. Drill-Tec 3 in. Ribbed Round Galvalume® plated 3" Round GAF Galvalume Plate (Flat) steel stress plate with reinforcing ribs for use with Drill-Tec"` fasteners. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 5 of 27 EVIDENCE SUBMTMD: Test A=ency Test Identifier Description Date Factory Mutual Research Corp. 3014547 4470 05/22/03 3029832 4470 05/11/07 3033135 4470 11/24/08 3034312 4470 04/09/09 3036980 4470 08/14/09 3038278 4470 11/18/11 3040738 4470 11/16/10 3041769 4470 05/26/11 3042887 4470 11/14/11 3042905 4470 01/10/12 3046081 4470 02/13/13 3046388 4470 09/24/12 3047636 4470 08/08/13 ODOA8.AM 4470 07/09/99 OD1A8.AM 4470 07/29/94 OY9Q5.AM 4470 04/01/98 1B9A8.AM 4470 09/04/97 2B8A4.AM 4470 07/02/97 3B9Q1.AM 4470 01/08/98 3D4Q2.AM 4470 05/30/97 797-03221-267 4470 09/27/07 797-03825-267 4470 07/21/08 797-10228-267 4470 01/23/15 UL LLC R1306 UL 790 08/21/18 PRI Construction Materials GAF-122-02-01 TAS 139 05/07/06 Technologies, LLC GAF-270-02-02 ASTM D226 11/15/10 GAF-276-02-01Rev ASTM D6083 12/16/10 GAF-276-02-02 ASTM D226 11/15/10 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-417-02-01 ASTM C1289 05/28/13 GAF464-02-01 ASTM C1289 10/22/12 GAF-464-02-01 ASTM C1289 02/06/14 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 GAF-549-02-01 TAS 114 08/08/14 GAF-549-02-02 TAS 114 08/08/14 GAF-559-02-01 TAS 117(B) 09/30/14 GAF-559-02-04 ASTM D 1876 10/01/14 GAF-559-02-05 ASTM D 1876 10/15/14 GAF-559-02-06 TAS 114(H) 10/02/14 GAF-559-02-07 ASTM D 903 10/02/14 GAF-559-02-08 ASTM D 903 10/02/14 NOA No.:18-0919.07 MIAMN=E COUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 6 of 27 EVIDENCE SuB rrTED: (CONTENUED) Test Agency Test Identifier Descriation Date PRI Construction Materials GAF-559-02-09 ASTM D 903 10/02/14 Technologies, LLC GAF-559-02-11 TAS 114 10/14/14 GAF-559-02-12 TAS 114 10/14/14 GAF-559-02-13 TAS 114 10/15/14 GAF-559-02-14 TAS 114 10/15/14 GAF-559-02-15 TAS 114 10/15/14 GAF-559-02-16 TAS 114 10/15/14 GAF-559-02-18 TAS 114 10/15/14 GAF-559-02-19 TAS 114 04/16/15 GAF-628-02-01 ASTM C1289 05/31/16 IRT of S. Fl. 02-005 TAS 114 01/18/02 02-014 TAS 114 03/22/02 Trinity ERD C8500SC.11.07 TAS 117 11/30/07 G30250.02.10-3-R2 ASTM D3909 06/03/15 G31360.03.10 ASTM D6164 03/31/10 G33470.01.11 ASTM D6164 11/16/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 ASTM D6401 06/04/15 G34140.04.11-5-R3 ASTM D4897 06/04/15 G36780.07.11 Rl 4470-TAS 114 07/18/11 G40630.01.14-1 ASTM D6163 01/06/14 G40630.01.14-2A ASTM D6164 01/07/14 G40630.01.14-2A-1-Rl ASTM D6164 04/10/14 G43610.01.14 ASTM D3909 01/22/14 G6850.08.07-1 ASTM D3909 08/13/07 SC6870.08.14-R1 ASTM D3909 09/04/14 SC9700.08.15-R1 ASTM D2178 8/31/2015 SC10680.05.16 ASTM D6163 5/10/2016 SC13105.03.17-R1 ASTM D6164 3/23/2017 Dynatech Engineering Corporation #4482.02.95-1 TAS 114 09/01/95 Atlantic & Caribbean Roof 11-053 TAS 114 08/12/11 Consultants, LLC NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 7 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(2): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or (optional) VersaShield® Solo"'` Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Stratavene Venting Nailable Base Sheet is secured as described below. Fastening Miami -Dade County Approved min. 12 ga. Annular ring shank nails and min. 1-5/8 in. Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: -45 psf. See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. Annular ring shank nails and min. 1-5/8 in. Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. aximum Design Pressure. 52.5 psf, See General Limitation #7 Fastening Drill -Tee #14 Fasteners and Drill -Tee 3 in. Standard Steel Plates, Drill -Tee Option #3: AccuTrac® Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. -52.5 psf. See General Limitation #7) Fastening Drill -Tee #14 Fasteners and Drill -Tee 3 in. Standard Steel Plates, Drill -Tee Option #4: AccuTrac® Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: -60 psf. See General Limitation #7) Fastening Drill-TecTu #14 Fasteners and Drill -Tee 3 in. Standard Steel Plates, Drill -Tee Option #5: AccuTrac® Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: -75 psf. See General Limitation #7) One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe EnergyGuard7 Polyiso Insulation, EnergyGuar&' Tapered Polyiso Insulation, EnergyGuard7 Ultra Polyiso Insulation, EnergyGuard71 RH Polyiso Insulation, EnergyGuard" RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 11 of 27 Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe EnergyGuard7' Perlite Roof Insulation Minimum %" thick N/A N/A Structodek® High Density Fiberboard Roof Insulation Minimum %" thick N/A N/A Securock® Gypsum -Fiber Roof Board, DensDeck® Prime Roof Board Minimum %" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20401bsJ100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet (Optional : GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth adhered in a full mopping of hot asphalt applied at 2040 lbs./sq. installed per manufacturer's installation instructions. Ply Sheet: When optional base sheet and/or cap sheet is present: Two or plies ot GAFGLAS® Ply 41 Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 2040 lbs./sq. installed per manufacturer's installation instructions. When optional base sheet and/or cap sheet is not present: Three or more plies of GAFGLAS® Ply 4, TriPly® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 2040 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet (Optional): GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCar Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.:18-0919.07 Expiradon Date: 11/04/23 Approval Date: 11/08/18 Page 12 of 27 WOOD DECK SYSTEM LEVIITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex Ply 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum %4" DensDeck' Roof Board or Y2"' Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LmTATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psE 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specif cally referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 27 of 27 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.gov SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initialinthe designated space indicates that the item has been explained. 1.�'! Aesthetics -Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2._Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck isusuallyconcealed prior to removing the existing roof system). 3. Y fir_ _ Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. I" J/LExposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptab . This provides the option of maintaining the appearance. S. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. RevOI 142021 Owners roofing consideration Page 1 of 2 0 7 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.qov TYr Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the ro4./, Owner/Agent's Signature Date / Contractor Date For Forms and Applications click here: http://bidg.miamishoresvillage.com/WebLink/Browse.aspx?id=118080&dbid=0&repo=Mia mi5horesVillage ReV01 142021 Owners roofing consideration Page 2 of 2 TGFU.R1306 - Roofmg Systems Page I of 4 TGFU.R1306 Roofing Systems Page Bottom Roofing Systems See General Information for Roofina Systems GAF 1 CAMPUS DR PARSIPPANY, N3 07054 USA R1306 "RUBEROID@ 20 Smooth" or "RUSEROID@ Mop Smooth" or "RUSEROID@ Mop Smooth 1.5" may be utilized as an alternate to Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri-Ply® #7S Base Sheet" or "GAFGLAS@ #80 Ultlma'" Base Sheet" base sheets in any of the following Classifications. 1/2-in. thick (minimum) gypsum board or 1/4-in. thick (minimum) Georgia-Pacific Gypsum LLC 'DensDecke Roofboard" or "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard"14 Roofboard" or 1/4-In. thick (minimum) United States Gypsum Co. "SECUROCK@ Roof Board' (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (lS/32-In. thick minimum) roof decks. However, the butt joints In the gypsum board and Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard'" Roofboard" are to offset a minimum of 6-In. with the butt joints In the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. 1/4-in. thick (minimum) "SECUROCK@ Roof Board" (Type FRX-G) and "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) are limited to a maximum 3:12 slope when used over a combustible deck in a system with any UL Classified insulation except polystyrene. Multiple plies of Type G1 "GAFGLAS@ Ply 4" or "Tri-Ply® Ply 4" or "GAFGLASO Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6" may be adhered to Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard'' or "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard " Roofboard" In hot roofing asphalt. "GAFGLAS@ FlexPly'" 6 5L" and "GAFGLAS@ FlexPly'" 6" may be used interchangeably In any roof covering system listed below. "EnergyGuard'" Ultra" is an acceptable alternate to "EnergyGuard'"" in any applicable Classification. "GAFGLAS@ Stratavent@ Nailable Venting Base Sheet" may be mechanically fastened or fully adhered with hot roofing asphalt over noncombustible decks and as a recover over existing roof systems. "EnergyGuard'" Periite Insulation" may be utilized as a cover board over "EnergyGuardl " in any of the following systems. Unless otherwise indicated, the roof insulation Is mechanically fastened, fully adhered with hot roofing asphalt or UL Classified urethane Insulation adhesive. Polystyrene referenced In any of the following Classifications include insulation. Unless otherwise indicated, all Insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's installation instructions (excluding "LRF Adhesive O") in any applicable Non -Combustible Roof Deck Classifications. "EnergyGuard"" Tapered" is an acceptable alternate to "EnergyGuardTM" In any applicable Classification. "EnergyGuard'" Ultra Tapered" is an acceptable alternate to "EnergyGuard'" Ultra" In any applicable Classification. "EnergyGuard"4 NH Tapered" is an acceptable alternate to "EnergyGuard'" NH" in any applicable Classification. "EnergyGuardT" NH Ultra Tapered" Is an acceptable alternate to "EnergyGuard'" NH Ultra" in any applicable Classification. "EnergyGuardTm Barrier Tapered" is an acceptable alternate to "EnergyGuard' Barrier". "EnergyGuard'" NH Barrier Tapered" is an acceptable alternate to 'EnergyGuard"4 NH Barrier". Minimum 1-In. thick "EnergyGuard" Barrier" is an acceptable alternate to "EnergyGuard'" Ultra" In any applicable Classification. Minimum 1-in. thick "EnergyGuard*" NH Barrier" is an acceptable altemate to "EnergyGuard*" NH Ultra" in any applicable Classification. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or "Tri-Ply® *75 Base Sheet" or "GAFGLAS@ 080 UltimaTM Base Sheet") is a suitable alternate for Type G1 asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS@ Flex Ply 6" or 'Tri-Ply(D Ultra - Flexible Ply 6") In the Class A, B or C roof systems Indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAFGLAS@ Stratavent@ Nailable Venting Base Sheet" or "GAFGLAS@ Stratavent@ Perforated Venting Base Sheet". Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets are to be mechanically fastened granule side down. As an option Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or'Tri-Plye #75 Base Sheet" or "GAFGLAS(D *80 Ultima'" Base Sheet" or "GAFGLAS@ Stratavent@ Nailable Venting Base Sheet") may be substituted for Type Gi asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or"Tri-Ply® Ultra -Flexible Ply 6") as the nalled base ply In the following systems. Bottom ply or base sheet may be fully adhered with hot roofing asphalt or mechanically fastened. Unless otherwise indicated, all insulations may be fully adhered with hot roofing asphalt or mechanically fastened. "GAFGLAS@ Flashing" or "RUBEROID@" may be used for flashing In any of the Class A, B or C systems listed below. http://database.ul.comlcgi-bftvXYVItemplatelLISEXTI1 FRAMElshowpage.html?name=TGFU.R 13 06&ccnshorL.. 5/ 1 /20I 8 TGFU.R1306 - Roofing Systems Page 2 of 4 When "perlite" is referenced, this includes any UL Classified perlite Insulation. Crushed stones or slag are suitable alternates for gravel in any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be Included as a deck In the following Class A, B or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Class A, 8 or C systems does not adversely affect the rating. The use of 1/2-In. minimum thick gypsum board Is an acceptable alternate for minimum Insulation over C-IS/32 thick roof decks. The use of polystyrene insulation board between minimum 3/4-in. thick perlite board and deck with rosin paper (perlite/rosin paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board In the following Class A, B or C systems. Trumbull "Perms Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGL.ASG *80 Ultima'" Base Sheet" may be used in any of the following systems. "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite Insulation In any of the following NC Classifications. Unless otherwise Indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "United Coatings'" FireShield MB Roof Coating" applied at a rate of 2-1/2 to 3-gal/100-ft?. Class A, 8 and C Hot roofing asphalt, for use with glass felts or modified bitumen membranes. "RUBEROIDO Heat Weld" SBS roofing membranes may be used in lieu of "RUBEROIDG Mop" SBS roofing membranes in any applicable Classification. Class A 1. Deck: C-15/32 Incline: 3 Barrier Board (Optional): — One or more layers minimum 1/4- "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuardTM Roof "SECUROCKG Roof Board" (Type FRX-G) or "SECUROCKG Glass-1 Vapor Barrier (Optional): — One or more plies "GAF® SA Vapc Insulation: — One or more layers perlite or wood fiber or glass f composite or perlite/urethane composite or wood fiber/poiylsocya Ply Sheet: — Three or more plies Type G1 "GAFGLASG Ply 4" or Ply 6", fully adhered with hoot roofing asphalt. Surfacing: — Gravel. 2. Deck: C-15/32 Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4- "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard"' Roof "SECUROCKG Roof Board" (Type FRX-G) or "SECUROCKG Glass -I Insulation: — One or more layers perlite or wood fiber or glass f composite or perlite/urethane composite or wood fiber/polyisocya Ply Sheet: — Three or more plies Type G1 "GAFGLASG Ply 4" or Ply 6", fully adhered with hot roofing asphalt. Cap Shot: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheer Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphi 3. Deck NC Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4- "DensDeckG Prime Roofboard" or "DensDeck® DuraGuardl Roo' "SECUROCKG Roof Board" (Type FRX-G) or "SECUROCKG Glass - Insulation (Optional): — One or more layers perlite or wood fit perlite/polyfsocyanurate composite or perlite/urethane composite Ply Sheet: — Two or more plies Type G1 "GAFGLASG Ply 4" or 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLASG Mineral Surfaced Cap Sheet Mineral -Surfaced Cap Sheer, fully adhered with hot roofing asph; 4. Deck: C-15/32 Incline: i Slip Sheet (Optional): — Red rosin paper, nailed to deck. Insulation (Optional): — Any thickness perlite or wood fiber c OMG Inc. "OlyBond Fastening System" or any UL Classified Insu Base Sheet: — One ply Type G2 'GAFGLASG #7S Base Sheer or "GAFGLAS® Stratavent® Nailable Venting Base Sheet", med Ply Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLASG Mineral Surfaced Cap Shee Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asp Coating (Optional): — "United Coatings'" TOPCOAT® Energy( Coatings'" Roof Mate MB Plus Coating" applied at a rate of 2-ga' 5. Deck: NC Incline. 3 thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or )rd" or minimum 1/4-In. thick United States Gypsum Co. Roof Board" (Type SGMRX). etarder" self -adhered r or polyisocyanurate or urethane or periite/polyisocyanurate ate composite or phenolic, any thickness. f-Ply® Ply 4" or "GAFGLASG Flex Ply 6' or "Tri-Ply® Ultra -Flexible thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or ind" or minimum 1/4-in. thick United States Gypsum Co. Roof Board" (Type SGMRX). or polylsocyanurate or urethane or pertite/polyisocyanurate ate composite or phenolic, any thickness. i-Ply® Ply 4" or "GAFGLASG Flex Ply 6" or "Tri-Ply® Ultra -Flexible "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLASG EnergyCap'" h. thick Georgia-Pacific Gypsum LLC "DensDeck(D Roofboard" or ward" or minimum 1/4-in. thick United States Gypsum Co. lat Roof Board" (Type SGMRX). er or glass fiber or pofyfsocyanurate or urethane or )r wood fiber/polyisocyanurate composite or phenolic, 2-in. maximum. ri-Plyp Ply 4" or "GAFGLASG Flex Ply 6" or "Tri-PIyG Ultra -Flexible Ply or "Tri-PfyG BUR Granule Cap Sheer or "GAFGLASG EnergyCap'" )lass fiber or polyisocyanurate mechanically fastened or adhered with ion adhesive. "Tri-Ply® #7S Base Sheet" or "GAFGLASG #80 Ultima'" Base Sheet" iically fastened. ri-Ply® Ply 4" or GAFGLASG Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLASG EnergyCap"o :TM Roof Coating" or "TOPCOAT® MB Plus Coating" or "United 00-ft.Z. Base Sheet: — One ply Type G2 "GAFGLASG #75 Base Sheet' jr "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultima'" Base Sheet" or "GAFGLASG StrataventG Nailable Venting Base Sheer or "GJFGLASO Stratavent® Perforated Venting Base Sheet" or "GAFGLASG http://database.ul.corn/cgi-binIXYVItemplatelLISEXTI I FRAMElshowpage.html?name=TGFU. R l 346&ccnshort... 5/ 1 /2018 TGFU.R1306 - Roofing Systems Page 3 of 4 Stratavent@ Nailable Venting Base Sheet" or "GAFGLAS® Strataven adhered with hot roofing asphalt. Ply Sheet: — One or more plies Type Gi "GAFGLAS@ Ply 4" or "Tri. 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 6. Deck: C-1S/32 Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuardT" Roofbo "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCKO Glass -Ma Insulation: — One or more layers perlite or glass fiber or polyisocy, perlite/urethane composite or phenolic, 1-in. minimum (offset a min Base Sheet: — One or more plies Type G1 'GAFGLASO Ply 4" or'T Ply 6" or Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Bi "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule asphalt. Membrane: — One or more plies "RUBEROID@ Torch Smooth" or'" 'RUBEROIDO Torch 180" or "Tri-Ply® APP Granule", torch applied o "RUSEROID® Mop Plus Smooth" or "RUSEROID@ Mop Granule" or": roofing asphalt. Cap Sheet, — Type G3 "GAFGLASO Mineral Surfaced Cap Sheet' or Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 7. Deck: C-15/32 Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. "DensDeck@ Prime Roofboard" or "DensDeck® DuraGuardT" Roofboi "SECUROCK@ Roof Board" (Type FRX-G) or "SECUROCKG Glass -Mat Insulation (Optional): — One or more layers periibe or wood fiber perlite/polyisocyanurate composite or perlite/urethane composite or Base Sheet: — Two or more plies Type G2 "GAFGLAS@ #75 Base S Base Sheet' or "GAFGLAS® Stratavent@ Nallable Venting Base Shee "GAFGLAS@ Stratavent@ Nallable Venting Base Sheet" or "GAFGLAS "GAFGLASO Mineral Surfaced Cap Sheet" or'Tri-Ply® BUR Granule 1 asphalt. Ply Sheet (Optional): — One or more plies Type Gi "GAFGLASO A Flexible Ply 60, fully adhered with hot roofing asphalt. Membrane: — One or more plies "RUBEROIDG Torch Smooth" or "1 "RUBEROID® Torch 180" or'Tri-Ply® APP Granule", torch applied or "RUSEROID® Mop Plus Smooth" or "RUBEROID@ Mop Granule" or "I roofing asphalt. Cap Sheet: — Type G3 "GAFGLASG Mineral Surfaced Cap Sheet" or Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. S. Deck: NC Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. "DensDeck® Prime Roofboard" or "DensDeck@ DuraGuardT" Roofboi "SECUROCKO Roof Board" (Type FRX-G) or "SECUROCKG Glass -Mat Insulation (Optional): — Peri€te or glass fiber or polyisocyanurate Base Sheet: — One or more plies Type G2 "GAFGLASO #75 Base SI Base Sheet" or "GAFGLASO Stratavent@ Nallable Venting Base Shee "GAFGLAS® Stratavent® Nallable Venting Base Sheet" or "GAFGLAS fastened or fully adhered with hot roofing asphalt. Ply Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri- 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet' or asphalt. Coating: — "United CoatingsT" FlreShleld MS Roof Coating" applied 9. Deck: C-15/32 Incline: 1 Barrier Board (Optional): — One or more layers minimum 1/4-in. I "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuardT" Roofboa "SECUROCK@ Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Insulation (Optional): — One or more layers perlite or wood fiber r perlite/polyisocyanurate composite or peri€te/urethane composite or i Ply Sheet: — Three or more plies Type G1 "GAFGLAS(D Ply 4" or "Tri Ply 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or Mlneral-Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 10. Deck: NC Incline: i Barrier Board (Optional): — One or more layers minimum 1/4-in. "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuardT" Roofboi "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Insulation (Optional): — One or more layers perlite or wood fiber 4 periite/polylsocyanurate composite or perlite/urethane composite or Ply Sheet: — Two or more plies Type G3 *GAFGLASO Ply 4" or "Tri-I 6", fully adhered with hot roofing asphalt. Perforated Venting Base Sheet", mechanically fastened or fully ® Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply i-Ply® BUR Granule Cap Sheet" or "GAFGLAS@ EnergyCapT" ck Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or " or minimum 1/4-In, thick United States Gypsum Co. )of Board" (Type SGMRX). rate or urethane or perllte/polyisocyanurate composite or m of 6-in. from plywood deck joints). ly@ Ply 4" or 'GAFGLASO Ply Flex 6" or "Tri-Ply® Ultra -Flexible Sheet" or "GAFGLASO #80 UltimaI" Base Sheet" or Type G3 o Sheet", mechanically fastened or fully adhered with hot roofing city® APP Smooth" or "RUBEROID@ Torch Granule" or ,UBEROID® Mop Smooth" or'RUBEROID@ Mop Smooth 1.5" or ec Flex PRF' or'Tri-Ply(ID SBS Granule" fully adhered with hot BUR Granule Cap Sheet" or "GAFGLASO EnergyCapT" Ick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or i" or minimum 1/4-in. thick United States Gypsum Co. ,oaf Board" (Type SGMRX). glass fiber or polylsocyanurate or urethane or )ad fiber/polylsocyanurate composite or phenolic, any thickness. .et" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaT" or "GAFGLASO Stratavent@ Perforated Venting Base Sheet" Stratavent@ Perforated Venting Base Sheet" or Type G3 p Sheet", mechanically fastened or fully adhered with hot roofing 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Ply Flex 6" or'Tri-Ply@ Ultra- -Ply@ APP Smooth" or "RUSEROIDG Torch Granule" or RUBEROIDO Mop Smooth" or "RUBEROID@ Mop Smooth 1.5" or ec Flex PRF" or "Tri-Ply® SBS Granule" fully adhered with hot BUR Granule Cap Sheet" or "GAFGLASO EnergyCapT" ick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or i" or minimum 1/4-in. thick United States Gypsum Co. oaf Board" (Type SGMRX). wood fiber or mechanically fastened, any thickness. Be or "Tri-Ply® #75 Base Sheet" or "GAFGLAS@ #80 UltimaT" or "GAFGLAS® Stratavent@ Perforated Venting Base Sheet" or Stratavent@ Perforated Venting Base Sheet', mechanically ,® Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri-Ply@ Ultra -Flexible Ply BUR Granule Cap Sheet", fully adhered with hot roofing a rate of 2-1/2 to 3-gal./100-ft.2. ick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or i" or minimum 2/4-in. thick United States Gypsum Co. oaf Board" (Type SGMRX). glass fiber or polylsocyanurate or urethane or od fiber/polylsocyanurate composite or phenolic, any thickness. 1IyG Ply 4" or "GAFGLAS@ Flex Ply 6' or "Tri-Ply® Ultra -Flexible BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapT" !ck Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or I" or minimum 1/4-in. thick United States Gypsum Co. oaf Board" (Type SGMRX). glass fiber or polylsocyanurate or urethane or ad fiber/pclyisocyanurate composite or phenolic, 2-1n. maximum. -® Ply 4" or "GAFGLASO Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply http://database.ill.comlcgi-bin/XYVItemplate/LISEXT/1 FRA,MElsbowpage.html?name=TGFU.R1306&ccnshorL.. 5/1/2018 TGFU.R1306 - Roofing Systems Page 4 of 4 Cap Sheet: — Type G3 "GAFGLASO Mineral Surfaced Cap Sheet" of Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 11. Deck: NC Indine: 2 Base Sheet: — One ply Type G2 "GAFGLASO #75 Base Sheet" or or "GAFGLAS@ Stratavent@ Nailable Venting Base Sheet" or "GAFF fastened or fully adhered with hot roofing asphalt. Ply Sheep — One or more plies Type G1 "GAFGLASO Ply 4" or "T 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" i Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphal 12. Deck: C-15/32 Indine: 1 Barrier Board (Optional): — One or more layers minimum 1/4-li "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuardT" Rooft "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCKO Glass-M Insulation: — One or more layers perlite or glass fiber or polyisoc perlite/urethane composite or phenolic, 1-in. minimum (insulation, Base Sheet: — One or more plies Type Gi "GAFGLASO Ply 4" or' Ply 6" or Type G2 "GAFGLASO #75 Base Sheet" or'Tri-Ply® #75 1 Stratavent@ Nailable Venting Base Sheet" or "GAFGLAS@ Stratavt Surfaced Cap Sheet" or "Tri-Ply@ BUR Granule Cap Sheet", meche Membrane: — One or more plies "RUBEROID® Torch Smooth" or Torch Granule" or "RUBEROID8 Torch 1800, torch applied or "RUB "RUBEROIDO Mop Plus Smooth" or "RUSEROID@ Mop Granule" or roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS(ID Mineral Surfaced Cap Sheet" i Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphal 13. Deck: C-15/32 Incline: 1 BUR Granule Cap Sheet" or "GAFGLASO EnergyCap— ,@ #75 Base Sheet" or "GAFGLASO 480 UitimaT" Base Sheet" Stratavent@ Perforated Venting Base Sheet", mechanically Ply 4" or "GAFGLASO Flex Ply 6" or'Tri-Ply® Ultra -Flexible Ply "Tri-Ply@ BUR Granule Cap Sheet" or "GAFGLAS@ EnergyCap"" thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or trd" or minimum 1/4-in. thick United States Gypsum Co. Roof Board" (Type SGMRX). nurate or urethane or periite/polyisocyanurate composite or nts offset a minimum of 6-in. from plywood deck joints). i-Ply@ Ply 4" or "GAFGLASO Flex Ply 6" or "Tri-Ply® Ultra -Flexible se Sheet" or "GAFGLAS@ #80 UitimaT" Base Sheet" or "GAFGLASO @ Perforated Venting Base Sheet" or Type G3 "GAFGLASO Mineral ;ally fastened or fully adhered with hot roofing asphalt. ri-Ply@ APP Smooth" or " ri-Ply® APP Granule" or "RUBEROID@ OIDO Mop Smooth" or "RUBEROIDO Mop Smooth 1.5" or itec Flex PRF" or "Tri-Ply® SBS Granule", fully adhered with hot "Tri-Ply@ BUR Granule Cap Sheet" or "GAFGLAS@ EnergyCap " Barrier Board (Optional): — One or more layers minimum 1/4-in thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or '"DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard " Roofb ard" or minimum 1/4-1n. thick United States Gypsum Co. '"SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK@ Glass-M Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fibe or glass fiber or polyisocyanurate or urethane or perilte/polylsocyanurate composite or periite/urethane composite o wood fiber/poiyisocyanurate composite or phenolic, any thickness. Base Sheet: — Two or more plies Type G2 "GAFGLASO #75 Base heer or'Trl-Ply® #75 Base Sheet" or "GAFGLASO #80 Ultima°" Base Sheet" or "GAFGLAS@ Stratavent@ Nailable Venting Base Sh t" or "GAFGLASO Stratavent® Perforated Venting Base Sheet" or Type G3 "GAFGLASO Mineral Surfaced Cap Sheet" or "Tri-Ply® BU Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet (Optional): — One or more plies Type GI "GAFGLAS@ ly 4"' or "Tri-Ply@ Ply 4" or "GAFGLAS@ Ply Flex 6" or "Tri-PlyO Ultra - Flexible Ply 6", fully adhered with hot roofing asphalt. Membrane: — One or more plies "RUBEROIDO Torch Smooth" or ri-Ply@ APP Smooth" or "Tri-Ply@ APP Granule" or "RUBEROID@ Torch Granule" or "RUBEROIDO Torch 1800, torch applied or "RUB OIDO Mop Smooth" or "RUBEROID@ Mop Smooth 1.5" or "RUBEROID@ Mop Plus Smooth" or "RUBEROIDO Mop Granule" Flex PRF" or "Tri-Ply® SBS Granule", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" "Tri-Ply@ BUR Granule Cap Sheet" or "GAFGLASO EnergyCap'" Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 14. Deck: C-15/32� incline: 2 Barrier Board (Optional): — OOne or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard " Roofboard" or minimum 1/4-1n. thick United States Gypsum Co. "SECUROCKO Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polylsocyanurate or perlite/poiylsocyanurate composite or wood fiber/poiyisocyanurate composite any thickness mechanically or adhered with hot roofing asphalt. Base Sheet: — One ply "GAFGLAS® Stratavent@ Perforated Venting Base Sheet" or Type G2 "GAFGLAS@ #75 Base Sheet"or'Tri-Ply® #75 Base Sheet" or "GAFGLASO #80 UltlmaT" Base Sheer or "GAFGLAS@ StrataventO Nailable Venting Base Sheer or "GAFGLASO Stratavent@ Perforated Venting Base Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet: -- Two or more plies Type G1 "GAFGLASO Ply 4" or "Tri-Ply@ Ply 4" or "GAFGLAS® Ply Flex 6" or "Tri-Ply@ Ultra -Flexible Ply 6" or "RUBEROID@ Mop Smooth" or "RUBEROIDO Mop Smooth 1.5" or "RUBEROIDO Mop Plus Smooth", "Ruberold@ 20 Plus Smooth" or "RUBEROIDO 20 Smooth", fully adhered with hot roofing asphalt. Membrane: — Type G3 "Tri-Ply® BUR Granule Cap Sheer or "GAFGLAS@ Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCapT" Mineral -Surfaced Cap Sheer, fully adhered with hot roofing asphalt. http://database.ul.com/cgi-bin/XYV/template/i.ISEXT/1FRAME/showpage.html?name=TGFU.R1306&censhort... 5/1/2018 2 W-flp, �i M Ron DeSantis, Governor Halsey Beshears, Secretary dbpr a STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD THE ROOFING CONTRACTOR HEREIN IS CERTIFIED UNDER THE PROVISIONS OF CHAPTER 489, FLORIDA STATUTES rq ! - Flinn ADDERLY DEVELO �f �; 5079 NORTH D 7 I *' 258 OAKLAND PARK FL 33334 LICENSE NUMBER: CCC1327886 EXPIRATION DATE: AUGUST 31, 2022 Always verify licenses online at MyFloridaLicense.com Do not alter this document in any form. This is your license. It is unlawful for anyone other than the licensee to use this document. BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100. Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2021 THROUGH SEPTEMBER 30, 2022 DBA: Business Name:ADDERLY DEVELOPMENT INC Receipt #: 185 -1759 ROOFING/SHEET METAL Business Type: (ROOFING CONTRACTOR) Owner Name:TODD R ADDERLY Business Opened:i0/25/2007 Business Location: 5079 N DIXIE HWY 4258 State/County/Cert/Reg:CCC1327886 OAKLAND PARK Exemption Code: Business Phone: Rooms Seats Employees Machines Professionals 1 --� --- - ----- For Vending Business Only - -�-1 Number of Machines: Vondino Tvoe: Tax Amount Transfer Fee NSF Fee Penalty _ _ 0.00 Prior Years Collection Cost Total Paid 30.00 27.00 3.00 0.00 0.00 0.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements This Business Tax Receipt must be transferred when the business is sold. business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations Mailing Address: TODD R ADDERLY 5079 N DIXIE HWY 4258 OAKI.AND PARK, FI, 33334 Receipt #30A-20-00010473 Paid 09/23/2021 30.00 2021 - 2022 ACORD,. CERTIFICATE OF LIABILITY INSUR_ANC_ E o �,_„ __._.._.. .. 121 POOOUCEi MAPLES INSURANCE AGENCY __ _ _°� THIS -CERTIFICATE IS ISSUED AS A lIAATTER OF _'_tktp710N l E SAMPLE ROAD STE E ONLY AND CONFERS NiO MGM UPON THE CERI19 CATE HOLDER. THIS CERI FICATE DOES NOT AMEND. EXTEND OR PO POMPANO BEACH, FL 33064 ALTER THE COVERAGE AFFORQED �Y W. RO�ICtES BFlONY ' Phone 9649458940 Fax 9649468942 ... ---- -- -- - -MWARERS AFFORDING COVERAGE.. j INSURED ADDERLY DEVELOPMENT, INC INSURER.!►. HUDSON EXCESS INS CO _ _ _-- ' 5079 NORTH DIXIE HWY #258 INsuRER B: OAKLAND PARK, FL 33334INSURER -- -- - ._ E: COVERAGES INSURERF:........_._.___._._----...---.._...�..__.____.. THE POLICIES OF INSURANCE LISTED HAVE BEEN ISSUED TO THE NYSURED lWW1ED ABOVE FOR THE POLICY PERIOD INDICATED. IJIORVlftFt T ANY REQUIREMENT, TERRA OR CONDITION OF ANY CONTRACTOR OTHER DOCUIYENT WITH RESPECT TO M ICH THIS CERTIFICATE iG MAY BE EI D EVER MAY PERTAIN. THE mURANCE AFFORDED BY THE POLICIES DESCRIBED FBI E SUBECT TO ALL THE TER A. EXCLUSIONS AND CONDITIONS OF SUCH POLICIFS. AGGREGATE LUIMTS SHOMW MAY BEEN REDUCED BY PAID CLAW. 3"%RI ADM _HAVE - _ - +TM . Ttt 1 arset0 TYPE OF ENSIURANiCE POLICY NUMBER POLICY EFFECTEVE D TE POLICY or►Te _ LIMITS GENERAL LIABU rnr EACHOCCURRENCE 1,000.000 COMMERCIAL GENERAL LIABILITY KBD900303674 11/10/21 11h Qf22 PE 3ES 100,000 CLAW MADE ® OCCUR up w. (..... a A ❑ ❑ PERSONALS •r ❑ GENERAL AGGREGATE ^ 1000 GEML AGGREGATE LAWT APPLIES PER: PRODUCTS - COMPIOP AGG 1.000_000 ' ® POLICY ❑ PROJECT ❑ LOC -. _._ AUTOMM E LIABI I Y ❑ ANY AUTO CONIMM SINGLE LIMIT . _....._ ❑ ALL OWNED AUTOS ❑ ❑ SCMfDUtED AUTOS sO01LYuItY: -} ❑ HIRED AUTOS !� ❑ NON OWNED AUTOS 8000.Y INJURY (PIN e=kb ) ❑ - - - I ....- ._........ . __.___._ . _ ... .. .....-.-__ PROPERTYDAMAGE �____ _----- • • ---r_..._ t GARAGE LIABILRY AUTO ONLY - EA ACCIDENT n ANY AUTO ❑ -AUTO.ONI:Y: _ . . �,• i i .. EXCESS LIABILITY ..... EACH OCCURRENCE iElUR ❑ OCCXCLAIMS MADE AGGREGATE j E MPLOYERV UMNUff A r+il..-----�.. ' -ANY PROPRIETOR / PARTNER I EXECUTIVE E.L. EACH ACCIDENT _ OFFICER I MBWIBER EXCLUDED? E.L. DISEASE - EA EMPLOYEE SPECIAL --- H yes, dBacabs ucder . ... S - ----- --- - - - - SPECIAL PROVISIONS I bgbw .. • -- • . • .... ----_ _-_ - _ ..... E.L. DISEASE - POLICY LMT _ OTHER iDESCRIPTION OF OPE RATIOMS! LOCATHONIa / VEHICLES I EXCLt$SKM ADOED BY ENDQR3E3lEI rT / SPECIAI. PROVISIONS 4 - CERTIFIED ROOFER CCC1327886 (CERTIFIED GENERAL CONTRACTOR CGC1506459 CERTIFICATE HOLDER # Miami Shores Village Bldg Dept 10050 NE 2nd Ave Miami Shores, FL. 33138 ACORD 25 (2001M) CANCELLATION SH O" ANY OF THE ABOVE D POMMS BE CAM=AA BPVp E THE � EXPIRATION DATE THEREOF, THE ISSUING 30 DAYS MRITTEN NoTHcE To THE CERTIFICATENORN THE LEFT, BUT FAILURE TO DO SO SHALT. M5K= NO OBLIETATWN OR LIABLITY OF ANY KIND UPON THE INSURER. ITS AGEM'8 OR IMPREUNWiTATNH38. AVTHORMED REPRE ITATIVE __.—_.._- • _ -- J DE ROSA G ACORD CORi�ORA7 !ON 1 0 JIMMY PATRONIS CHIEF FINANCIAL OFFICER STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW * * CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 1/9/2022 PERSON: TODD R ADDERLY FEIN: 141954619 BUSINESS NAME AND ADDRESS: ADDERLY DEVELOPMENT INC 5079 NORTH DIXIE HWY #258 FORT LAUDERDALE, FL 33334 SCOPE OF BUSINESS OR TRADE: Contractor -Project Manager, Construction Executive, Construction Manager or Construction Superintendent EXPIRATION DATE: 1/9/2024 EMAIL: ADDERLYDEV@YAHOO.COM IMPORTANT: Pursuant to subsection 440.05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to subsection 440.05(12), F.S., Certificates of election to be exempt issued under subsection (3) shall apply only to the corporate officer named on the notice of election to be exempt and apply only within the scope of the business or trade listed on the notice of election to be exempt. Pursuant to subsection 440.05(13), F.S., notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 08-13 E01437233 QUESTIONS? (850) 413-1609 Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice to Owner - Workers' Compensation Insurance Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if 1. The officer owns at least 10 percent of the stock of the corporation, or in the case of an LLC, a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State, Division of Corporations; and 3. The corporation is registered and listed as active with the Florida Department of State, Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. . Your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use day labor, part-time employees or subcontractors for your project. The contractor has provided an affidavit stating that he or she will be the only person allowed to work on your project. In these circumstances, Miami Shores Village does not require verification of workers' compensation insurance coverage from the contractor's company for day labor, part-time employees or subcontractors. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. Signature: Owner State of Florida County of Miami -Dade /�% The foregoing was acknowledge before me this /C/ day of '.7 �"'7 20z/ SEAL / who is personallyPubown to me or has produced as identification. .�.,.� qp.J CHIOUITA POSTELL *c Notary Public -State of Florida Commission # GG 338980 My Commission Expires July 11, 2023 Adc�erly ;Developrner�f WIN: 6544454076 Fa 1466d06-0)55 Certified General Conlruw CRC 15060.9 - Rooter CCC 132 W Date: State of �bL County of7t—O41� ♦41� Before me this day personally appeared o, being duly sworn, deposes and says: That he or she will be the only person working on the project located at: p (il Contractor Sig I Sworn to (or affirmed) and subscribed before me this day of .20 � by Personally know__—�_ OR Produced Identification Shantel Trinaye Rorie Notsry Public Type of Identification Produced State of Florida My Commission Expires 05/04/2024 Commission No. GG 984254 7 Print, Type or Stamp Name of Notary