MCC-11-20-2547v HVAC Load Calculations For RICARDO PADULA 790 N.E.91 STREET #4 MIAMI SHORES, FL. 33138 I RHVACWAC o s a ti. i' New � m m Sara#. rr 10- Pre are By: KERRY October 01, 2020 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are perf—ormed per ACCA ManualEdition, Version 2, and ACCA ManualD. Rhvac - Residential B Light Commercial HVAC Loads JOFRE Engineering Design Elite Software Development, Inc. .� General Project Information Project Title: NEW SYTEM Project Date: 10/01 /2020 Client Name: RICARDO PADULA Client Address: 790 NE 91 ST #4 Client City: MIAMI FL.33138 Reference City: MIAMI SHORES, Florida Building Orientation: Front door faces south Daily Temperature Range: Medium Latitude: 25 Degrees Elevation: 9 ft. Altitude Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 50 46 n/a n/a 70 n/a Summer: 90 77 56% 50% 75 55 Total Building Supply CFM: CFM Per Square ft.: 0.768 Square ft. of Room Area: 140 Square ft. Per Ton: 600 Volume (ft') of Cond. Space: 2,925 is Total Heating Required Including Ventilation Air: 12,000 Btuh 22.859 MBH Total Sensible Gain: 9,000 Btuh 80 % Total Latent Gain: 2,814 Btuh 20 % Total Cooling Required Including Ventilation Air: 12,000 Btuh 4.00 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. E:\ ...\Isp homes Residence.rh9 Thursday, October 16, 2014, 10:44 AM Rhvac - Residential & Light Commercial HVAC Loads jofre Engineering Design Elite Software Development, Inc. Description Quan Loss Gain Gain Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 12 260 0 772 772 metal frame with break, u-value 1.08, SHGC 0.5 1A-cb-o: Glazing -Single pane, operable window, clear, 112.1 2,419 0 6,132 6,132 metal frame with break, u-value 1.08, SHGC 0.5 11 A: Door -Wood - Hollow Core 60.1 564 0 735 735 12A-5sw: Wall -Frame, no insulation in stud cavity, R-5 1647.6 3,922 0 4,215 4,215 board insulation, siding finish, wood studs 16A-30: Roof/Ceiling-Under Attic with Insulation on Attic 365 1,016 0 3,555 3,555 Floor (also use for Knee Walls and Partition Ceilings), Unvented Attic, No Radiant Barrier, Any Roofing Material, Any Roof Color, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 193 5,242 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 13,423 0 15,409 15,409 People: 4 800 920 1,720 Equipment: 500 1,200 1,700 Lighting: DUCTLESS 1,023 1,023 Ductwork: 6,395 1,363 6,403 7,766 Infiltration: Winter CFM: 138, Summer CFM: 112 3,041 4,151 1,846 5,997 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Exhaust: Winter CFM: 100 Summer CFM: 100 System 1 Ahu-1 Load Totals: 22,859 6,814 26,801 33,615 Check Fonurert Supply CFM: 180 CFM Per Square ft.: 0.768 Square ft. of Room Area: 180 Square ft. Per Ton: 567 Volume ft' of Cond. Space: 11,077 Total Heating Required Including Ventilation Air: 12,000 Btuh 22.859 MBH Total Sensible Gain: 9,000 Btuh 80 % Total Latent Gain: 2,814 Btuh 20 % Total Cooling Required Including Ventilation Air: 12,000 Btuh 2.80 Tons Based On Sensible + Latent Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. E:\ ...\Isp homes Residence.rh9 Thursday, October 16, 2014, 10:44 AM FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: NEW CENTRAL SYSTEM Builder Name: Street: 790 N.E. 91 STREET #4 Permit Office: City, State, Zip: MIAMI SHORES, FL, 33168 Permit Number: Owner: RICARDO PADULA Jurisdiction: 232600 Design Location: FL, MIAMI 1. New construction or existing Existing (Project 9. WaII Types (180. sqft.) Insulation Area 2. Single family or multiple family NEW CENTRAL SYSTEM a. Concrete Block - Int Insul, Exterior R=5.0 800. Oft' b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (140 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 800 ft2 6. Conditioned floor area above grade (ft2) 800 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (55..64 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 317.4 a. U-Factor: Sgl, U=1.08 55.64 ft2 SHGC: SHGC=0.50 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 4800 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 23.9 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.170 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems 8. Floor Types 800.0 sqft.) Insulation Area a. Electric WATER TANK Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 800ft' b. EF: 0.990 N/A R= ft2 C. b. Conservation features N/A R= ft2 None Glass/Floor Area: 0.078 Total Proposed Modified Loads: 44.32 PASS Total Standard Reference Loads: 55.23 I hereby certify that the pla ar Ns� ca{ip�is Q er d Review of the plans and K 8T4>, this calculation are in co p' e wilethe �� specifications covered by this O�"�E Code. ;��tr -:� fi. calculation indicates compliance the Florida Energy Code. ti .• +� with .r,,,,, • ,\ a PREPARED BY: Before construction is completed DATE: 10- - �`�, r '= ,� o 4 this building will be inspected for ;� a compliance with Section 553.908 ° I hereby certify that this buildingx tisannce Florida Statutes. with the Florida Energy Code. yyE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 10/16/2014 10:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: NEW CENTRAL SYSTEM Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 800 Lot # Owner: NWAEZEH INT. LLC Total Stories: 1 Block/Sub Division: # of Units: 1 Worst Case: No Plat Book: Builder Name: Rotate Angle: 0 790 N.E. 91 STREET Permit Office: Cross Ventilation: County: DADE Jurisdiction: 232600 Whole House Fan: City, State, Zip: MIAMI, FL. Family Type: Single-family FL 33138 New/Existing: Existing (Projected) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL_MIAMI_INTL_AP 1 51 90 70 75 149.5 56 Low BLOCKS Number Name Area Volume 1 Block1 140 2700.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 140 2700.5 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 49 ft 0 800 ft2 ---_ 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch IV/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 365 ft2 0 ft2 Medium 0.96 No 0.9 No 0 14 ATTIC v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 140 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 365 ft2 0.11 Wood 10/16/2014 10:42 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt Space To Wall Type o 1 W Exterior Concrete Block - Int Insul Main 5 25.08 9.5 225.0 ft2 0 0.75 0 _ 2 S Exterior Concrete Block - Int Insul Main 5 12.33 9.5 108.1 ft2 0 0.75 0 3 E Exterior Concrete Block - Int Insul Main 5 25.08 9.5 225.0 ft2 0 0.75 0 4 N Exterior Concrete Block - Int Insul Main 5 12.33 9.5 108.1 ft2 0 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area -_ _ -- Ft- _- In Ft In 1 W Wood Main None .46 3 6.7 20 ft2 2 S Wood Main None .46 3 6.7 20 ft2 3 E Wood Main None .46 3 6.7 20 ft2 WINDOWS / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 1 Metal Single (Tinted) Yes 1.08 0.5 25.0 ft2 1.17 ft 0 i 2 ft 0 in Drapes/blinds None 3 S 2 Metal Single (Tinted) Yes 1.08 0.5 12.8 ft2 1.17 ft 0 i 2 ft 0 in Drapes/blinds None 4 E 3 Metal Single (Tinted) Yes 1.08 0.5 12.8 ft2 1.17 ft 0 i 2 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Whole house Best Guess .0005 2081.4 114.26 214.89 .345 8.2832 HEATING SYSTEM # System Type Subtype Efficiency - Capacity _ _Block Ducts 1 MINI SPLIT None COP: 1 12.00 kBtu/hr 1 DUCTLES COOLING SYSTEM # System Type _ -Subtype- _ Efficiency Capacity Air Flow SHR Block Ducts 1 MINI SPLIT Split SEER: 15 12000 kBtu/hr VARIABLE 0.75 1 DUCTLES HOT WATER SYSTEM # System Type SubType Location EF Cap-- Use SetPnt Conservation 1 Electric TANK Main 0.99 40gal 60 gal 120 deg None 10/16/2014 10:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 350.4 ft Attic 79.35 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan ]Feb Mar A r Ma Jun X1 Jul X Au S Oct Nov Dec Heatin�X Jan Feb Mar �X� Apr May �X�Jun 1 Jul A Pss:p Oct f X� Nov X Dec Venting [[ Jan lXr [ j Feb XMar [X Apr [ l l ]May ]Jun [ Jul l [ Aug l e [X Oct [X Nov l Dec Thermostat Schedule: HERS 2006 Reference HOIrs Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 100 0 0 1 - Electric Strip Heat % 1 - Central Unit 10/16/2014 10:42 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 790 N.E. 91 STREET PERMIT #: MIAMI, FL, 33138 MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. X Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and X controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the X primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in X Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical X ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 N/A & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per X Tables 503.2.3. Equipment efficiency verification required. Special equipment I occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. R-19 space permitting. X Ceilings/knee walls 405.2.1 10/16/2014 10:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the Energy Performance Index, the more efficient the home. 790 N.E. 91 STREET MIAMI SHORES, FL. 33138 1. New construction or existing Existing (Project 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1 8 0 ft2 b. N/A R= ft2 c. 3. Number of units, if multiple family 1 N/A R= ft2 d. 4. Number of Bedrooms 1 N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 800 ft2 6. Conditioned floor area (ft2) 800 b. N/A R= ft2 7. Windows*" Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=1.08 124.10 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main R ft2 6 317.4 SHGC: SHGC=0.50 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. MINI SPLIT Unit 1200 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 23.9 COP:1.00 Area Weighted Average Overhang Depth: 1.170 ft. Area Weighted Average SHGC: 0.500 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 140 ft2 a. Electric EF: 0.99 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: �yO��81r STgT�o� �oD WE�� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software MIAMI-DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES http://www.miamidade.gov/building/home.asp 1/19/2021 8:22:11 AM ITrackinq # lProcess # 1Pe_rmit # 1121004671 IM2021004671 12021022393 THIS COPY OF PLANS MUST BE AVAILABLE ON BUILDING SITE OR AN INSPECTION STILL NOT BE MADE. Process # Review Disposition Reviewer Date M2021004671 DERM CORE A MOYA GRACE 1/4/2021 M2021004671 FIRE A A UIT SUYIN 1/4/2021 M2021004671 UPFRONT FEES A WEB APPLICATION ID 12/31/2020 M2021004671 WASA N 1PARERA, BELKYS 1/13/2021 M2021004671 IMPACT FEES N IDARRAGA MELINA 1/4/2021 Disclaimer. Subject to compliance with all Federal, State, and County Laws, rules and regulations. Miami -Dade County assumes no responsibility for accuracy of or results of these plans. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to the property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies or federal agencies. Stamp Name Trade Disposit Stamp Description ion Approved As FIRE P Approved as noted. See comments, markups and Noted stamps. APPROVED -SCOPE FIRE A APPROVAL FOR SCOPE OF WORK ONLY EXISTING PORTIONS ONLY OF BUILDINGS SHALL COMPLY WITH THE PROVISIONS OF EXISTING OCCUPANCIES AS SET FORTH IN THE FL FIRE PREVENTION CODE Reference Only.FIRE R Reference only. Approved DERM JA JApproved