Loading...
RF-12-20-2892, 10 NE 103rd StMiami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address. Parcel Number 10 NE 103RD ST, Miami Shores, FL 33138 1132060131620 'ontacts Michael Willard Owner ROOFS TO GO USA LLC Contractor 10 NE 103 ST, MIAMI SHORES, FL 33138 MICHAEL MCDONALD 5392 SW 33 AVE, FORT LAUDERDALE, FL 33312 Business: 3052162723 Inspection Requests: Description: RE -ROOF TILE Valuation: $ 22,000.00 "f , Total Sq Feet: 2,750.00 IN �/ u Fees Amount Application Fee - Other $50.00 CCF $13.20 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $4.40 Roofing Fee $250.00 Scanning Fee $12.00 Technology Fee $7.50 Total: $344.60 Building Department Copy Payments Date Paid Amt Paid Total Fees $344.60 Check # 2528 12/21/2020 $294.60 Check # 2511 12/16/2020 $50.00 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: dvner--- / Applicant / Contractor / Agent Date December 21, 2020 Page 2 of 2 RECEIVED I Z 1 ►P,t-Lo , t. f , BUILDING Miami Shores Village qA2� Building department 100S0 N.E.2nd Avenue, Miami Shores, Florida 33338 Tel: (30S) 79S-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (30S) 762-4949 u1't,020 BY: FBC 20 l --A Master Permit No. 12 - 7K3 ` *ZE" 2— PERMIT APPLICATION Sub Permit No. []BUILDING ❑ ELECTRIC ® ROOFING REVISION EXTENSIONRENEWAL [PLUMBING M MECHANICAL ❑PUBLIC WORKS 0 CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS 109 ADDRESS: 10 NE 103 ST Folio/PameNf 1 1-3206-013-1620 is the Building Historically Designated: Yes NO Occupancy Type: RESLoad: Construction Type: RES Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): IUIICHAEL WILLARD Phone#: Address: 10 NE 103 ST may; MIAMI SHORES State: FL Zip; 33138 Tenant/Lessee Name: I I A Phone#: Email: CONTRACTOR: Company Name: ROOFS TO GO USA LLC Phone#: 305-216-2723 Address: 5392 SW 33 AVE Cay: FORT LAUDERDALE state: FL Zip: 33312 Qualifier Name: MICHAEL MCDONALD Phoned: 305-216-2723 State Certification or Registration #: CCC 13_ 658 Certificate of Competency #: DESIGNER: Architect/Engineer. h A I A Phone#: Address: City: State: Zip: Value of Work for this Permit: $ $22,000 Square/Unear Footage of Work: 2750 Type of Woft ❑ Addition ❑ Alteration ❑ New I@ Repair/Replace El Demolition Description of Work: RE -ROOF TILE Specify color of coloyr� t�hru tile: PTO N k m OO N -11kI b] h Lt—N e"" Submittal Fee $ b ' `�y Permit Fee $ CCF $ CO/CC S Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Tra ning/Educatkon Fee $ Double Fee $ Structural Reviews $ (RevW42/24/2024) Bond $ TOTAL FEE NOW DUE $ �� y - 60 Scanned with CamScanner Bonding Company's Name (if applicable) Bonding Company's Address City Mortgage tender's Name (if Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or Installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of an laws regulating construction In this jurisdiction. I understand that a separate permit mint be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..,. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and toning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction dun low brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature, OWNER or/,GENT The foregoing instrument was ac nowledged before me this -�-�.--day offbe G Q. w4kl;b ,,�. 20 Z 0 .. by B Lra21 w jN% a fC who is personall Aown to me or who has produced N 5+9_0�tias Identification and who did take an ok?& Signature /4 CONTRACTOR The foregoing instrument was acknowledged before me this 1 0 day of ($:C 20 Z by t&%Q1_P&l .ffiQbffiD. who is personally known to me or who has produced -as as Identification and who did take an oath. NOTARY Pusued, / Print: O Print J !'I Rao Ekum Dal ROW E Nosary u x e Seal: My Gt3 t2o4a7 Seal: VrAsna ZUleta �aw Expir" 081Z MI My Commission GG'2sa784o ------------ - ��� Expims0210312023 I wo APPROVED BY Examiner Zoning Structural Review (Rev4edOl/224=e1 Clerk Scanned with CamScanner Property Search Application - Miami -Dade County Page 1 of 1 ,_ OFFICE OF THE PROPERTY APPRAISER :.; Summary Report Property Information Folio: 11-3206-013-1620 Property Address: 10 NE 103 ST Miami Shores, FL 33138-2327 Owner MICHAEL WILLARD Mailing Address 10 NE 103 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 4/2/0 Floors 1 Living Units 1 Actual Area 1,747 Sq.Ft Living Area 1,747 Sq.Ft Adjusted Area 1,655 Sq.Ft Lot Size 9,757.8 Sq.Ft Year Built 1950 Assessment Information Year 2020 2019 2018 Land Value $292,449 $292,449 $243,834 Building Value $115,188 $115,188 $115,188 XF Value $736 $740 $745 Market Value $408,373 $408,377 $359,767 Assessed Value $408,373 $395,743 $359,767 Benefits Information Benefit Type r 2020 2019 2018 Non -Homestead Cap Assessment Reduction $12,634 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 1 534165342 MIAMI SHORES SEC 1 AMD PB 10-70 LOT 10 & N1/2 LOT 11 BLK 12 LOT SIZE 75.060 X 130 OR 18348-2785 1198 1 Generated On : 12/16/2020 Taxable Value Information 2020 2019 2018 ............. County Exemption Value $0 $0 $0 Taxable Value 1 $408,373 $395,743 $359,767 School Board Exemption Value $0 $0 $0 Taxable Value $408,373 $408,377 $359,767 City Exemption Value $0 $0 $0 Taxable Value 1 $408,373 $395,743 $359,767 Regional Exemption Value $0 $0 $0 Taxable Value $408,373 $395,743i $359,767 Sales Information Previous OR Book- Price Qualification Description Sale Page 30665- 08/14/2017 $421,200 Qual by exam of deed 0498 30395- Corrective, tax or QCD; min 01/12/2017 $100 0079 consideration 28351 10/04/2012 $272,000 Qual by exam of deed 0308 25823- Sales which are disqualified as a result 07/01/2007 $0 2262 of examination of the deed The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:/hvww.miamidade.gov/info/disclaimer.asp Version: https://www.miamidade.gov/Apps/PA/propertysearch/ 12/16/2020 Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANTTO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: MICHAEL WILLARD Property Address:—,10 NE 103 ST Roofing Permit Number: Dear Building Official: M I rn�clnoe ( ��llo,r certify that I am not required to retrofit the roof to wall connections of my building because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000,00. Please attach proof of ad valorem taxation. P,The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) CA Si ature Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this -I*h day of :Q Zoz o Notary Public, Sate of Florida at � v N Notary Pubdc State of Flotlda +� Rosa Ebna ON Ronal E i My t,orrlrnissiar QQ 120447 �' Expires 06J2912021 _ • When the fust valuation of Te stru�tu-v for purpose of ad valorem taxation is equal le or mote than $300.300 CO. arw he t; : d ng was not constructed with FBC nor a I9W SFBG. Theta you rnusl provide a budding sWicoton from a General Gordractorfor the Roof tc Wall owmection HLrritatte M tigation Revised on WIM9 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. _ M^%Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4443. (The roof deck is usually concealed prior to removing the existing roof system). 4.W Exposed Ceiling; Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. tV Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeterledge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. - - 0 n s Signa _ re ___ Date Property Address Revised on 7/9/2009 LD;0710112015; / -A" rI f (ow-() Contractor Signature ' Date Permit Number Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: O 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: l` (Jkkk-e` Property Address: 10 K1 �-- 101 S T Roofing Permit Number: Dear Buil ing Official: I — �Q KU kh&Q certify that I have improved the roof to wall connections of the referenced property as required by the Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Residential Structures as adopted by the Florida Building Commission by Rule 96-3.047 F.A.C. Signature State of Florida County of Dade K1kQ aclld Print Name The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this K)day of 20 Z Notary Public, Sate of Florida at Large U +}""�"'' ►�ua� S a fa��� f' Com "SM GG 297640 n r%Z 02/03/2023 (SEAL) FINAL COMPLIANCE Revised on 5/21/2009 Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CONTRACTORS' REGISTRATION IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. COPY OF QUALIFIER'S STATE LICENCES B. COPY OF LOCAL BUSINESS TAX RECEIPT C. / COPY OF LIABILITY INSURANCE* D. --7— COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICATE OF COMPETENCY OF QUALIFIER B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT. D. COPY OF LIABILITY INSURACE* E. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) *YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW: Certificate Holder: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 Certificate must specify the description of operations or contractor license number. ........................................................................................... BUSINESS NAME: kun `WC) Coo k)s - LLL BUSINESS ADDRESS: S691 c5 W 33 Av tc CITYRZ- �,.NQMIzQ WSTATE l ZIP-31111 BUSINESS PHONE: (30S) V (z ` 2 Q Z 3 FAX NUMBER L--j CELL PHONE (9-�fl) -6 -"6 y QUALIFIER'S NAME: K kC-RkL MC_ N& Q QUALIFIER'S LIC NUMBER: Cam. L Q�b Z6 S B DATE ACC>Rbr CERTIFICATE OF LIABILITY INSURANCE 12-1OD�'21 2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terns and Conditions of the policy, certain policies may requlre an endorsement. A statement on this certficate does not confer to t!u comifrcate holder in lieu of such endorsems s . PRODUCER COalT:CT INKim Son -Shalom S_ Marker Insurance, Inc. P" 954p45t; 750s A c w l;_(s►5.t)IIse ss20 1720 Harrison Street 6-A was,. kimmarlcerineurarRt e.eom Hollywood, FL 33020 IISURERIst AFFORDING COVERAGE . _ NANC p INSURED Roofs to Go USA, LLC 5392 SW 33th Ave Fort Lauderdale, FL 33312 L`AVCDAN:CS CRDTICU_ATC An IYRPD- 0aaeCa69J1 0CVN4IAIJ YIIYRFD. I THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ._.._.__... _A�POl1CY INSR r_.__._._. ...._...TYPE LTR OF INSURANCE NUMBER (INAMDIYYYYI UNITS A X + COO ORCAL GENERAL UASLmr 0100129501.0 10112t2020 10112M21 i EACH OCCURRENCE aDAMAGE 1,OOa,000_ CLAIMS -MADE ;_x._ OCCUR TOREN . ' S _ 1oo a00 two EXP yy y w win} s_. EXCLUDED PERSONAL a ADV INJURY $, 1,000,990 GEN`L AGGREGATE LIMIT APPLIES PER: ', ; GENERAL AGGREGATE $- 2,000,000 X; POLICY - JE LOC i PRODUCTS -COMPIOPAGG $_ 2,0009000-- OTHER; - S AUTOMOSLE LIABILITY CO#Aw*O SINGLE LIMIT $ _iESaam") ANY AUTO - --- BODILY INJURY (Per person) ( $ OWNED SCHEDULED AUTOS ONLY _. _ AUTOS INJURY (Par sxdaM); $ HIRED NON -OWNED �i; PR�+ERTY DAMAGE S _..: AUTOS ONLY _. AUTOS ONLY !;s ... UMBRELLA UAS OCCUR ::EACH OCCURRENCE t_S.. ... EXCESS LIAR CLA4MS-MADE DED RETENTION S AGGREGATE f.. B SL„COMPENSATIONr t WC-90000-2020 OTK AOilSM020 0110112021 X P� ER STATUTE FJ1 AM ANY PROPRIETOR/PARTNERF-XECUTNE Y I—"- N F k _ _ E L EacH ACCto£rrtr $ _. ACCIDENT 1,000 wO OFFICERAER EXCLUDED? £ (MaMatery in NH) _._ EL DISEASE -EA,EMPLOYEE 3-- .. 1,000,000 yea tXW.SCRt OF PERATKMNS below ` E-L- DISEASE - POLICY LIMB S 1 0a0 aaa DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 1e1. AddlSenal RamarYa Schedule, may be attached I mwe ayaee Is re**Wed ROOFS TO GO USA LLC IS A CONSTRUCTION COMPANY MICHAEL MCDONALD CCC1332658 Miami Shores Village Bldg Dept 10050 NE 2nd AVE Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ®1988-2015 Ali riahts reserved. ACORD 25 (2016103) The ACORD name and logo are registered marks of ACORD Prated by KBS on Decernber 01, 2020 at 07:50AM CITY OF HOLLYWOOD TREASURY SERVICES DIVISION LOCAL BUSINESS TAX ROOFS TO GO USA, LLC 5392 SW 33 AVE HOLLYWOOD, FL 33312 Please contact us with any changes or corrections to your information. CUSTOMER SERVICE: Should you have any questions regarding Local Business Tax or need to update / correct any information related to your Business Tax Account, please contact us by phone at 954-921-3225, by email at businesstax@hollywoodfl.org or in person at City Hail, Room 103, 2600 Hollywood Blvd. Please send all written correspondence to: City of Hollywood, Treasury Services Division, Attn: Business Tax, Room 103, PO Box 229045, Hollywood, FL 33022-9045. PURSUANT TO STATE LAW, LOCAL BUSINESS TAX IS LEVIED FOR THE PRIVILEGE OF DOING BUSINESS WITHIN A CITY'S LIMITS, AND IS NON -REGULATORY IN NATURE. ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT BY THE CITY OF HOLLYWOOD DOES NOT MEAN THAT THE CITY HAS DETERMINED THAT THE EXISTING OR PROPOSED USE OF A LOCATION IS LAWFUL. ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT DOES NOT LEGALIZE OR CONDONE THE NATURE OF THE BUSINESS BEING CONDUCTED IF CONTRARY TO ANY LOCAL, STATE OR FEDERAL LAW OR REGULATION. THIS IS NOT A BILL. DO NOT PAY. BELOW IS YOUR LOCAL BUSINESS TAX RECEIPT. PLEASE DETACH AND POST THIS LOCAL BUSINESS TAX ,► RECEIPT IN A CONSPICUOUS PLACE AT YOUR PLACE OF BUSINESS. CITY OF y�FA v D(AMON / LD COAS ti FFF FLORIDA 8AtE� �qti 2020/2021 LOCAL BUSINESS TAX RECEIPT Business Name: ROOFS TO GO USA, LLC DBA: Business Location: 5392 SW 33 AVE Business Category: SERVICE/LICENSED BUSINESS Classification: Contractor/Roofing Tax Basis: 2 - 4 WORKERS Account Registration #: B9069430-2021 Expiration Date: 9/30/2021 Tax Rate: $251.00 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH -VELOCITY HURRICANE ZONES - UNIFORM PERMIT APPLICATION Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. RECEIVED Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 A,B,D,E 1,2,3,4,5,6,7 Concrete or Clay Tile A,B,D 1,2,3,4,5,6,7 Metal Roofs Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations • Applicable Detail Drawings • • • 3. Design Calculations per Chapter 16, or If Applicable, RAS 127rar.RAS 128 •••••• 4. Other Component of Product Approval • • 5. Municipal Permit Application : • • • S. Owners Notification for Roofing Considerations (Reroofing Obly)* 7. Any Required Roof Testing/Calculation Documentation FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING 6.31 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Process No. Contractor's Name ROOFS TO GO USA LLC Job Address 10 NE 103 ST ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ New Roof ❑ Repair Low Slope Roof Area (SF) N/A ❑ Prescriptive BUR-RAS 160 ROOF TYPE X Mortar/Adhesive Set Tile ❑ Wood Shingles/Shakes No gas vent ❑ Maintenance Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 2750 Total (SF) 2750 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. poop poop.. .. poop.. • e poop.. poop poop• ... poop. oeeeso poop.. pose Dose 16.32 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING EL ,. i r � f y i t4 3 • •••• • • • • • ?_ • •• ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) Roof System Manufacturer: Boral Roofing LLC Notice of Acceptance Number: 19-1021.11 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculation11. -39.1 P2: -68.1 P3: -100.7 e PERIMETER 6 Steep Sloped Roof System Description Deck Type: 5/8" plywood medium paddy \Typendeiryment: 30# ASTM Roof Slope: 4 : 12 n: N/A Barrier: N/A Ridge Ventilation?Fastener Type & Spacing: 121 4r10 L La N/A Rs 4TTY Mean Roof Height: 15 Type Cap Sheet: Polystick TU PLUS self adtgact, Roof Covering: F COncrel1 _ Type & Size Drip �Wlgalv. 213 • • • • Edge: ...... 16.34 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P1. 39.1 x, 0.301 11. 76) _ Mg: 6.90 = Mr14.86 Product Approval Mf 38-7 (p2; 68.1 x QJD1 =20.49) - Mg: 6.90 = Mr213-53 Product Approval Mf 38.7 (P3100.7 x a0.301 =30.31) - Mg: 6.90 = M,,23.41 Product Approval Mf 38.7 Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height -> Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for Fwith the values for Fr. If the Fvalues are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS 127" (Pl: x L = x w: = - W: x cos B -=Frl Product Approval F (P2: x L = x w: = -----) - W: x cos 8 = Fr2 Product Approval F (Pa: x L = x w: = - W: x cos B _=F, Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure PI or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier J Product Approval • • Restoring Moment due to Mg Product Approval • • • • • • Gravity Attachment Resistance M Product Approval • • Required Moment Resistance M Calculated • • • • • • Minimum Attachment F Product Approval • • • • • • 0000 Resistance • • • • Required Uplift Resistance Fr Calculated • • • • • • • • • • • Average Tile Weight W Product Approval • • L=length •••• ••• Tile Dimensions Product Approval • W = width • • • All calculations must be submitted to the building official at the time of permit application. I FLORIDA BUILDING CODE 6th Edition (2017) - BUILDING 16.36 MIAMK + MIAMI-MADE COUNTY I AMD PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami. Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) &. `"•°�movitygnom Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER'- Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer"s name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it:4ijille.4e done in its entirety. • • • ' •. • • • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturePois a tlistrilRrtorl and shall be available for inspection at the job site at the request of the Building Official. •..... This NOA revises NOA No.19-0408.02 and consists of pages I through 7. The submitted documentation was reviewed by Freddy Semino a iAPPRflYED' ...... .... • • • PA No.:19 I021.11:"": Expiration Dltw.44/26/22 Approval Date: tl/21/19 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Cateeory: Roofing Sub-Catesorv: Roofing Tiles Material: Concrete I. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Allplicant Dimensions SIR!Mifications Dglcrjption Barcelona 900 Length = 17" TAS 112 Sigh profile, interlocking, one-piece, 'S' shaped, Width = 13" Type — la high-pressure extruded concrete roof the '12" thick equipped with three nail holes. For direct deck or battened nail -on, mechanically fastened, mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete Width: varies roof pieces for use at hips, rakes, ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset* AH-160 TILE BOND" Roof Tile Adhesive DAP Foam Touch N Seal StormBond* 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Two component polyurethane foam adhesive. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam Inc. • o . . o •S . .. . • • .... . • o •SSSS• •••S •woo• • • • • • •Boss• • • • •• o Soso•• '•,• PANo.;JZ021.11:ii•i:- Expiration D'atuo94/26/22 Approval Date: 11/21/19 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test Aeency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix I1 TAS 108(Nail-On) Redland Technologies P0402- Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Professional Service Industries, Inc. [C-1320-94 Physical Properties Feb. 1995 TAS 112 The Center for Applied Engineering, Inc. 25-7688-3 TAS 101 (Adhesive Set) June 1996 25-7688-10 TAS 101 (Mortar Set) July 1996 The Center for Applied Engineering, Inc. 25-7688-5 Static Uplift Testing June 1996 TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) The Center for Applied Engineering, Inc. 25-76884 Static Uplift Testing June 1996 TAS 102 0" Headlap, Nails, Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier 09/01/16 Walker Engineering, Inc. Evaluation Restoring Moments Due to 09/01/16 Calculations Gravity American Test Lab of South Florida RT0617.03-16 TAS 112 06/29/16 PRI Construction Materials Technologies COPO-002-02-10 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-02 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-01 Static Uplift Testing ; IOfh/2016...... TAS 101 (AdhestvAScQ .. • • • • 060000 Y • • •••• • • Y •...•• ••.•.. •..• • • 000000••..• ••. • • •••••• • . • • i • %, OA NooY��•i 1021.1 • • • • • .Y, MlAMtQADE CQUNTY • • 11tion xpira q;.04/26/22 Approval Date: 11/21/19 Page 3 of 7 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set the applications, a static field uplift test in accordance with TAS 106 may require, refer to applicable building code. 3.3 Applicant shall retain the services of Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Department of Regulatory and Economic Development -- Product Control Section for review, 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 Minimum slope 4/12 for mechanically attached tiles. 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight-W (ibf) 1 Length-1 (ft.) Width-w (ft.) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - A (W) Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Application Barcelona 900 0.286 0.301 Table 3: Restoring Moments due to Gravity - Mq (ft.-lbf) Tile Profile 2"•12" 3"•12" 4"•12" 5":12" 6"•12" . • . • . ,Z;;'(�" or • rgreater Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Cliseot 46" B e Direct• Dec N/A 7.07 1 N/A 7.001 6.19 6.90 6.06 6.76 5.92 460 5• 6.4 .se ...... .... .%N0A No.• 10 01021.1j••'•• ot�NT1r IN00 ation D%j:• 94/26/22 Approval Date: 11121/19 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf) for Mechanically` Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132" (min. 19132" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank 5.1 6.8 2.8 Nail 2-10d Smooth or Screw Shank 6.9 9.2 7.3 Nails 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank 23.1 23.1 19.0 Nail Field Clip) 1-10d Smooth or Screw Shank 29.3 29.3 24.0 Nail Eave Clip) 2-10d Smooth or Screw Shank 27.6 27.6 38.6 Nails Field Clip) 2-10d Smooth or Screw Shank 38.1 38.1 41.8 Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 installation with a 4" the headiap and fasteners are located a min. of 21W from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mt (ft-lbf) for Two Paddy Adhesive' Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 Tile Bond""One Component Roof Tile Adhesive 29.32 ICP Adhesives Polyset(g) AH-160 two -component foam 2 t31 • • see . . DAP Foam Touch N Seal StormBondl9 2 Roof Tile Adhesive • • • ; • • 86 • • • • • 1 See manufactures component aroval for installation requirements. 0 • • • • • • 2 TILE BONDTm Roof Tile Adhesive; Average weight per paddy 10.7 grams. ...... 0000 9 •; 3 ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160; Average weight per�Itldy8 graftu6 *sees 4 DAP Foam Touch N Seal StormBonda Roof Tile Adhesive Two-Com Went; Average weW94w paddy80rams. . .. . ...... .•. NOA•No*19-102C l..: Expiration Uate� 04/2�/22 .... Approval Date: 11/21/19 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment - Mt (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 ICP Adhesives Polyset,& AH-160 two -component foam 66.5 ICP Adhesives Polysett AH-160 two -component foam 38.76 DAP Foam Touch N Seal StormBond2 63' DAP Foam Touch N Seal StormBond- 2 82 8 5 Lar e paddy placement of 63 grams 6 Medium paddy Oacement of 24 grams 7 Medium paddy placement of 30 grams 8 Large paddy placement of 60 grams Table 8: Attachment Resistance Expressed as a Moment - Mr(ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Barcelona 900 Mortar Set' 24.5 9 Seespecific mortar manufacturers Notice of Acceptance 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". L�.J" LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE . . :""' ...... .. . .......... 6. BUILDING PERMIT REQUIREMENTS .• ...... . . 6.1 Application for building permit shall be accompanied by copies of the following' • • • ; • •; • .... . ..... 6.1,1 This Notice of Acceptance. . .. ... ... ..... 6.1.2 Any other documents required by the Building Official or applicable bus ins�•codc �n Nflor to properly evaluate the installation of this system. , •. • . .. . ...... : .•. NOA'No!'19-1021:11..: � � Expiratio►t Date:- 04/2fi/22 .... Approval Date: 11/21/19 Page 6 of 7 PROFILE DRAWING NAIL HOLES UNDERLOCK OVERLOCK BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE C �• ...... . .. ...... .... . ..... ...... .... ..... .. .. .. . ...... ...... 00 . . .. . ..... . . . . .'. NOA!No"19-102fL31..: Expiration i kc, 04/24/22 Approval Date: 11/21/19 Page 7 of 7 MIAMMAM M MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. Y • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer er its dlstribir''s ant shall be available for inspection at the job site at the request of the Building Official • • • • • 000090 . . This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. • • •: The submitted documentation was reviewed by Freddy Semino.I "" • CEcy • NOA No.F •17-0614.22 ....:. � f xplr%lion Date: 69%13/21 *J)preval Datex BZ/06/17 . 0Page for 8 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Dimensions Polystick IR-Xe 65' x 3'33/s" Manufacturing Or 65' x 3' Location # 1 & #2 60 mils thick Polystick Dual Pro Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick TU Max Manufacturing Location # I & #2 Polystick TU P Manufacturing Location #2 Polystick TU Plus (Surface Printing) Manufacturing Location #1 & #2 Polystick MTS Manufacturing Location #2 Polystick MTS Plus Manufacturing Location #2 Elastoflex S6 G Manufacturing Location #2 61' x 3'33/8" 60 mils thick 61' x 33 3/s" 60 mils thick Test Product Specification Description ASTM D 1970 A fine granular/sand top surface self -adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester ASTM D 1970 reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester ASTM D 1970 reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self -adhering, polyester reinforced 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile underlayment. 32'l0" x 3'3-'/s" TAS 103 and A rubberized asphalt waterproofing membrane, glass- 130 mils thick ASTM D 1970 fiber/polyester reinforced, with a granular surface designed for use as a tile roof underlayment. 65' x 3'33/a" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester 80 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. 65'8" x 3'33/s" TAS 103 A homogeneous, rubberized asphalt waterproofing 60 mils thick membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. 65'8" x 313/s" TAS 103 A homogeneous, rubberized asphalt waterproofing 60 mils thick membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. 32' l 0" x 3'3--%s" • • TAS 103 and Polyester reinforced, SBS modified bitumen aneftMr'dne Y . • • • • ASTM D 6164 with a sanded back face and a graiRuletop surface.• For + • use in roof tile underlayment sfSMIs.• .. +•..;+ •• •• •• • •••••• • •:144A No.: 1 T-0614.22 • • 'Expiration D4tb;, 09413/21 • + • • + • Ap&val DAte: W/06/17 • • •. •Pagejof 8 ;..++� MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED Test Aaencv Test Identifier Test Name/Reaort Date Trinity ERD P10870.09.08-RI TAS 103 12/04/08 P 10870.04.09 TAS 103/ASTM D4798 & G 155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.1 I ASTM D 1623 04/26/1) P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P40390.08.12-2 ASTM D 1623 08/07/12 P37590.07.13-1 ASTM D6164 07/02/13 P45270.05.14 TAS 103, TAS 110 & ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103 & TAS 110 10/07/14 P43290.10.14 ASTM D 1970 & TAS 110 10/17/14 PLYG-SC10130.06.16-3 TAS 103 & TAS 110 06/27/16 PLYG-10130.06.16-1 ASTM D1970 & TAS 110 06/27/16 PRI Asphalt Technologies PUSA-035-02-01 TAS 103 09/29/06 PUSA-055-02-02 TAS 103 12/I0/07 PUSA-089-02-01 TAS 103/ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. JX20H7A TAS 103/ASTM D4798 & G155 04/01/08 RX14E8A TAS 103/ASTM D4798 & G155 11/09/09 DX23D8B TAS 103/ASTM D4798 & G155 02/18/10- DX23D8A TAS 103/ASTM D4798 & G155 02/18/10 LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building shall be accompanied by copies of the following: ! • • • • permit 1. This Notice o Acceptance. .. . .. . • • • • • • • to the 2. An other documents required b the Building Official or applicable building code in orde • • • • • • erl eval 00 Y �l Y S PP g �W.IA7�p Y � installation of this materials. , • . .... . . ••...• . . • �••:4A Noi•17 2614.22 camri' •�••-• Expiration Date► 09#13/21 • • A•ppreval Date: W• 06/17 ......• • . i'a*e 2 of S 0 0 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick NITS Plus, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Elastoflex S6 G, hot asphalt applied Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. .000% ...... . .. ...... .... . ..... ...... .... ..... . . .. . 9660% NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have frill contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-fxistipg roof tretrttfrane as a recover system. • • so 0 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polysti& W P, Pol fsti*deiU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary*r88f f& longer thAn the amount of days listed in the table below after application. Polyglass reserves the right to Wigs or altdrpr:uct exposure times; not to exceed the preceeding maximum time limitations. ...... .... Ex osure Limitations (Davs) 000000 ., . MTS I IR-Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro e . TAIP Max 0 : MTS Plus .. . Winter Haven, FL 180 90 180 180 180 180 180 WO• W Hazelton, PA N/A 90 N/A 180 N/A N/A N/A • • 1 • •N/.A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 Rule 61 G20-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof the applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (0) Profile MTS S6 G TU P, Tile Pro, TU Max MTS Plus MTS Plus with Dual Pro TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6:12 Tile without battens 1 The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall be utilized during loading and installation of tiles. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four the stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. VIIe1 2 POL` nCKTU Plus • • • • • • • • •••• • ••••• •••••• •••• ••••• •• •• •• • •••••• • • • • • • • • • • • • NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick NITS, Polystick NITS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick NITS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area-para clavae, on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the the manufacturers NOA, must be used on all projec6for: • pitch/slopes ofT'/12" or greater. It is suggested that on pitch/slopes in excess of 61/"/12;'1 pWoitutionj �ho%lld be • • •, • taken, such as the use of battens to prevent tile sliding during the loading process. ...... . .. • ...... 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-EMght•(48) HourS. • • 8. Polystick membranes may not be used in any exposed application such as crickets, expose;*** or••c ib0 roof to wall details. .... • • ...... .... 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 F4editum Modified • ..... • • • •: • Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Preiniuin $Aodified • •. Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, foilowed by a peal tekgf the • • • • Polystick material of like kind should be set and hand rolled in lace over the area needi ik re air. m P �S � P PO1ph� g • • • • • • membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a%,%Nsd that water will run parallel to or over the top of all laps of the patch. EoaoEc NOA No.: 17-0614.22 APPROVED1 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 or 8 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE ...... ...... . .. .0000 .... . ..... ...... .... ..... .. .. •• • ...00 . . .. . ...... .. ...... •000 NOA No.: 17-0614.22 CMM*DA°ECO UFNITWY Expiration Date: 09/13n1 Approval Date: 07/06/17 Page 8 or 8 7COUNTIY�,.�.�41 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 S W 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. •••••• ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, a►td followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displax*J, then it sl0l,b; done in its entirety. • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufactuiti jol.its distdistt' m and shall be available for inspection at the job site at the request of the Building Official. 000000 • ... This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. 000000 • • • • • • • The submitted documentation was reviewed by Alex Tigera. • `tYaa�EOAota �� NOA No.: f?-0322.03 ,.!P • , Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof the adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A PolyseOAH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: TAS 101 Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Pro a Test Results Density ASTM D 1622 1.6 lbsJft.' : • • • : • Compressive Strength ASTM D 1621 18 PSI Parallel to rise • • •; • •' �:' • 12 PSI Perpendicular to rise • ...... Tensile Strength ASTM D 1623 . .. ...... 28 PSI Parallel to rise ...;.. • Water Absorption ASTM D 2127 0.08 LbsJF .... ...... Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch 0000 ..... Dimensional Stability ASTM D 2126 +0.07% Volume Change @-4foFy 2 weelm • •.:..' • +6.0% Volume Change @ 158°P.! eni 100% Hedity, 2 • • • • • • weeks •••••• • Closed Cell Content ASTM D 2856 86% • • • • • • • • Note: The physical properties listed above are presented as typical average values as de;Wi d. by .... ; • • • •; accepted ASTM test methods and are subject to normal manufacturing variation. '....' NOA No.: 17-0322.03 IT.;7!A-21!Le 7Y Expiration Date: 05/10/22 PPR• D � Approval Date: 04/27/17 Page 2 of 1 I EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01=6743-011 ASTM E 108 1 UI6/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not ,part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset' AH-160 shall solely be used with flat, tow, & high the profiles. :...:. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RRS.1 k .. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polysee AH-1'SiY Wtile a8heslOe with their tile assemblies shall test in accordance with TAS 101. """ 5. All products listed herein shall have a quality assurance audit in accordance with the Fldfida 0ilding',CtW and Rule 61 G20-3 of the Florida Administrative Code. ...... .... NOA No.: 17!OM2.03 Muvh�ecounrr Expiration Dater 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 maybe used with any roof the assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained.'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset AH-160 shall be applied with ICP Adhesives Foam DispenserRTF1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8.. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. sees:. .. .. . . sees.. . .. sees.0 sees.. 0. sees .sees. e e sees.* eese a :..see sees..• sees sees. . s . .. .. .esees.. • e . e . s .. . .sees. • . e se s . sees.. e 0 NOA No• -�M-Q322.03 Expiration Date? 18/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Minimum Paddy Contact Minimum Paddy Gram Tile Profile Placement Detail Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead - Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. MAMfl11DE=XUAN 'Y BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. •••••• • NOA No.: 111-a122.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of I 1 ADHESIVE PLACEMENT DETAIL # 1 Na OArow9hphstkcsom Paddymonoubme) tlda.ym.�r •; « 1 A`�, 101 frsur EawClow"� N•" through ph K cement hvhennyalted) 1 2ltirlde sommopd4mal FtiddylaYYYreh t r: Eire cle•aro Fascia Nd dw000 plank t•� requY•d) a`..- ?� t�r•.shTil.l 7 t`. totr.: • . E&mCo 1s@ - r R Fascia /y / 1!Yeepttole . domej^�lfYl/�/" i�fip •�• Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cmz) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cm'-) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positione6as shown •••••• under the pan portion of tIT tilg*qJosest to the • + • • • • overlock of the tile being set.* • ; • • • Y • ••• • •• • 2. Continue in same manner.;Yi?•d?e'approxim&ely 17 • •••••• ....: (109.7 CM2) — 23 (148.4 cnr) sq*u«re inAvadl)esive • contact with the underside of tie tile. • •: • •. •••••• •••• ••••• • NOA No•.:49N13•22.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6of11 ADHESIVE PLACEMuN"I' DETAIL # 2 , g 7 k% �j f EseDOMM kAdUG"OPUWC=ffl"1 twbep revimd) m Fneiw APPROYEDi Flat/i.ow Profile Tile 1. Starting at the eave course.. apple a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm�) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x T (177.8 mm) x I" (25.4 mm) foam paddy onto the underlay Went positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm) - 12 (77.4 cm: square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underla}Trent positioned as shown under the pan portion of the the closest to the overlock of the the being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the the closest to the overlock of the the being set. �...:. 3. Continue in same manner.. InsgrF,Appioximijel},V (77.4 cm2) -14 (90.3 cm) sqtXr. bjgb adhesive, contact with the underside ofthe tilq. • • Y1•••• •••••• •••• • • • (Instructions continued on nest roko • • •• • • •••• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04127/17 Page 7 of I ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) MaGdroughpttetitte 4wAenrequlrod) p�dT menrA6Tib) r T ._h f r Eswcooae ��i auia Wimphal• to ia. 2 ie Ewm dof.R Gr4p edge High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the the closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2) _ 19 (122.6 cm') square inch adhesive contact with the underside of the tile. ...... . .. ...... • •••••• .... . ..... •• •• M• • •••••• • •••••• • • • • •• • •••••• • • • • 0000 NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAII. # 3 �ett+oytptastica®etr t�sedtrthettieetttk:) B Paw es 2:4 tin. 'i ti - .�2 �redosve Flatti mProtileTile ties) I [Mill in; EamaeseR Medium ProfOeTile I. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x I" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in'- (109.7-148.4 cm2) of adhesive contact with the underside of the the 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x I" (25A mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course the to be installed. Insure approximately 8-9 in- (51.6-58.1 cm'-) of adhesive contact with the underside of the tile. (instructions continued on neripage) NOA No.: 17-0322.03 t1►4Detotxt7�r Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Katitt eoppW& ShujePaddrmdWdk twhmn ukera PaWylbetwemMal tta�an e . ' PmWriundwtno elk dx4tn. Sike 2s4 ppoftan toperde Fmtowse �` '� Fascia Weephok fain. tin. Eandomm .�' Ddpedge High laroflieTlte 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm') - 11 (71 cm2) square inch adhesive contact with the underside of the the at the overlap and 7 (45.2 cm2) - 9 (58.1 cm') square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. • • • 0:*0• •••••• • • •••••• •••• • ••••• •••••• •••• ••••• •• •• •• • •A•••• •••••• • • • • • • •• • • • •• t`narewr►oe eouHrr NOA No.: 17-0322.03 JAPPROVEDi Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 t) Place enough adhesive to schism 65 to 70 sq. In contan wkh the pan dle. 2)Turn omen upskle down. Plac3adhasi;ve in tot in.h a outside edge of eweThen InstMU thedle.Ensure20to 2Ssq.ln.aontectaroa.^e jnder� (mate►sho rn) Fas& ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Steep pkeh applications (whop required) Phone- - top portion of the tare course eorer tile.Abut to second course of pon Am Ensure eareerd of pan and corertAes are flush at eaweGne. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2 Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan the course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover the to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. `5. When additional nailingis required, mm) x 4" (101.6 mm) na4w; oc the tie&vire system using galvanizedt swinless steal, or•' copper wire and compatible his may be esed. •s•• • • ••e•s• ...• e END OF THIS ACCEPTANCE NOA No.: 17-0322.03 h�Ar`hFer►eh:eourrrr Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 • ••esY e•s•e Y