Loading...
MCC-11-20-2662, 11300 NE 2nd Ave Landon BldgMiami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Parcel Number 11300 NE 2ND AVE LANDON BUILDING, Miami Shores, FL 1121360000050 33161 Contacts BARRY COLLEGE Owner THERMAL CONCEPTS INC Contractor 11300 LAWRENCE DAVID MAURER JYao@barry.edu 2201 College Avenue, Davie, FL 33317 Business:9544724465 cburghardt@thermalconcepts.com Inspection Requests: Description: EXACT REPLACEMENT OF RTU#10 LOCATED ON Valuation: $ 45,415.87 It;t' ROOF OF THE LANDON BUILDING Total Sq Feet: 0.00 � ���3 �� � ,♦ �w �, � Fees Amount Application Fee - Other $50.00 CCF $27.60 DBPR Fee $23.84 DCA Fee $15.90 Education Surcharge $9.20 Permit Fee $1,539.56 Scanning Fee $9.00 Structural Review ($45) $45.00 Technology Fee $39.74 Total: $1,759.84 Payments Date Paid Amt Paid Total Fees $1,759.84 Credit Card 02/10/2021 $1,709.84 Credit Card 11/19/2020 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is curate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermorq%rfiUlt oorize tj�ekove iar ed coritFachpr to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Date February 10, 2021 Page 2 of 2 I-V 0\ /�o BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING ❑ ELECTRIC ❑ ROOFING RECEIVED BY: FBC20\�" Master Permit No. Sub Permit No. C] REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING X MECHANICAL ['PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOBADDRESS: 11300 NE 2nd Avenue - BARRY UNIVERSITY (LANDON BUILDING) s Folio/Parcel#:11-2136-000-0060 is the Buiklling Historically Designated: Yes No X Occupancy Type: Load:. Construction Type: _Flood Zone: _ BFE: FFE: _ OWNER: Name (Fee Simple Titleholder): BARRY UNIVERSITY Phone#,' Address;11300 NE 2nd Avenue City: Miami Shores State: FL Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Thermal Concepts, Inc. Phone#: 954-472-4465 Adder; 2201 College Avenue aty. Davie State. FL Zip. 33317 Qualifier Name: Lawrence D. Maurer Phone#• 954-472-4465 State Certification or Registration #: CAC039621 Certificate of Competency #: - DESIGNER: Architect/Engineer. ivr Phone#: Address: " Qty: " State: " Zip: Value of Work for this rtnit: $ 45,415.87 Square/Unear Footage of Work: Type of wodc ❑ ition ❑ Atter:t:o;nZ ❑ New ® Repair/Replace ❑ Demolition Description of Work: EXACT REPLACEMENT OF RTU#10 LOCATED ON ROOF OF THE L.ANDON BUILDING Specify color of color thru We: Submittal Fee $ �d , Q Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon; Fee $ Technology Fee $ Training/Education Fee $ DBPR $ Notary $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ � - / , V + (ReWsedO2/24/2014) Bonding Company's Name (if applicable) N/A Bonding Company's Address .. city State Mortgage Lender's Name (if applicable) ......... Mortgage Lender's Address .... ........ _,.. city State EM Zip Application is hereby made to obtain a permit to do the work and installations as Indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT- I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "'WARNING) TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT," Notice to Applicant.- As o condition to the issuance of a building permit with on estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. in the absence of s/uch.7 ted notice, the inspection will not be approved and a reinspection fee will be charged. ,.--^'� f Signature, _..... 4"a-t'i OWNER or AGENT ,s' CONTRACTOR The foregoing Instrument was acknowledged before me this The foregokW ldf,Intrument was ackn ledged before me this day of ,. 20 by 2ti by who is personally known to 1 e ufe who is Mssonally known to me or who has produced _. __.... identification and who did take an oath, PlQTARY PURL Sign. I1 i � v� 2 Print; ,IEFFRYJAWO 01010619f►#06249919 210 B TftF*bftarmmsE09,19 019 APPROVED BY as me or who has produced identification and who did take an oath. as NOTARY PUBLIC: Sign; Print; UI i- Seal: CUM XYY DALEY BURiiHAIW Nifty Public - State of Flgft � Baraftd tMou� National Natwy Aso. �arFs Examiner Zoning �.. Structural Review Clerk l RpY 15L rzai�2i 2#%�i'� iy j Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax:(305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): lC 30 C) /V-,e 9'vo City: Miami Shores Village County: Miami Dade Zip Code: �� I ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMiTALS AHRI DATA SHEET REQUIRED Change disconnecting means: YES❑ NO Q ARHI Sheet Attached: YES ❑ NO N Contract Attached: YES It UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER C7 �C L AHU or PKG. UNIT MODEL # -1 COND. UNIT MODEL # KW HEAT NOM TONS 12i S_ 'T'O-3S AHU CU dXDG 1) M.C.A AHU CU PKG AHU CU 2) M.O.P AHU CU PKG AHU CU M 4 (Q 3) VOLTS Coo q p AHU CU G PKG UNIT / / PKG UNIT EER/SEER YES NO REPLACING DUCTS YES NO YES NQ REPLACING THERMOSTAT ES NO YES O NEW 4"CONCRETE SLAB YES YES NO NEW ROOF STAND YES NO N (� YES NO NEW RETURN PLENUM BOX YES NO 1. Minimum Circuit Ampacity (Wire Size): �a 1k- vVTs:' � 2. Maximum Overcurrent Protectio usBre er Size F: /qV"t 1 ^ VT 3. Voltage of Circuit (208/24 480 : 4. Size Disconnecting Means: Contractor's Company Name: State Certificate or Sign Date: /r / ( -- %-a 2-0 (Revised02/24/2014) EXPIRATION DATE: AUGUST 31, 2022 Always verify licenses online at MyFloridaLicense.com Do not alter this document in any form. This is your license. It is unlawful for anyone other than the licensee to use this document. BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 1.15 S. Andrews Ave., Rm. A 100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2020 THROUGH SEPTEMBER 30, 2021 QBA.THERMAL CONCEPTS INC RACeipt#:HEATING/AIRCONDITION CONTRACTR Business Name: Business Type: (CERTIFIED AIR COND CONTR) Owner Name: LAWRENCE DAV I D MAURER Business Opened: 0 4 / 01 / 19 8 5 Business Location: 2201 COLLEGE AVE State!County/CertlReg:CA-0039621 DAVIE Exemption Code: Business Phone: 472-4465 Rooms seats Employees Machines professionals 10 For Vending Business Only Number of Machines: Vending Tiros: Tax Amount I Transfer Fee NSF Fee Penalty Prior Year. Collection Cost Total Paid 27.00 0.00 1 0.00 1 0.00 1 0.00 0.00 0.00 70000000000000000000000000026642021000000027001 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THUS BECOMES A TAX (RECEIPT This,tax is levied for the privilege of doing business within &award County and is non -regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location, This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. Mailing Address: THERMAL CONCEPTS INC 2201 COLLEGE AVE DAVIE, FL 33317 2020 - 2021 B.ROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. moo, Ft. Lauderdale, FL 33301-1895 — 954-8 4000 VALID OCTOBER 1, 2020 THROUGH SEPTEMBER 30, 2021 CSA:THERMAL CONCEPTS INC Business Name: Owner Name: LAWRENCE DAVID MAURER Business Location: 2 2 01 COLLEGE . AVE DAVIE Business Phone: 472-4465 Rooms seats Receipt#: 183-742 Business Type-HEATING/AIRCONDITION CONTRACTR (CERTIFIED AIR COND CONTR) Business Opened:04/01/1985 State/County/Cert/Reg: CA-0039 621 Exemption: Code: Employees Machines Professionals 10 slgpature For Vanding BusfnaosOhly Number. oumacbines. Vending -Type: Tax Amount 'transfer Fee NSF Fw Penalty Prior Years Collection Cast Total Paid 27.00 0.00 '0.00 0.00 0.00 0.00 0.00 700000000000000t100000050.00:0026642021000000027001 A Q-® CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DDIYYYY) 08/18/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Brown & Brown of Florida, Inc. A/CONN Exit: (954) 776-2222 FAX No): (954) 776-4446 E-MAIL Certs@bbftlaud.com ADDRESS: 1201 W C ress Creek Rd yp INSURER(S) AFFORDING COVERAGE NAIC # Suite 130 INSURER A : Amerisure Insurance Company 19488 Fort Lauderdale FL 33309 INSURED INSURER B : The North River Insurance Company 21105 INSURER C : Thermal Concepts Inc. INSURER D : 2201 College Avenue INSURER E : INSURER F : Davie FL 33317 COVERAGES CERTIFICATE NUMBER: 20-21Thermal REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER POLICY EFF MMIDD/YYYY POLICY EXP MM/DD/YYYY LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS -MADE � OCCUR PREMISES Ea occurrence $ 100,000 X MED EXP (Any one person) $ 5,000 Contractual & Contingent Liab X XCU Included PERSONAL&ADV INJURY $ 1,000,000 A CPP2115187001 09/04/2020 09/04/2021 GEN'LAGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY � PRO 1-1 LOC JECT PRODUCTS - COMP/OPAGG $ 2,000,000 $ OTHER: AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident $ 1,000,000 BODILY INJURY (Per person) $ X ANYAUTO A OWNED SCHEDULED AUTOS ONLY AUTOS HIRED NON -OWNED X AUTOS ONLY HAUTOS ONLY CA20566621301 09/04/2020 09/04/2021 BODILY INJURY (Per accident) $ PROPERTY DAMAGE Per accident $ UMBRELLA LIAR I X OCCUR EACH OCCURRENCE $ 5,000,000 B X EXCESSLIIAR CLAIMS -MADE 5821146621 09/04/2020 09/04/2021 AGGREGATE $ 5,000,000 X DED RETENTION $ 0 $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY YIN ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? N (Mandatory in NH) NIA WC206853911 04/01/2020 04/01/2021 PER STATUTE ERH X1 ' E.L EACH ACCIDENT 500,000 $ E.L. DISEASE - EA EMPLOYEE $ 500,000 If yes, describe under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT $ 500,000 A Equipment Floater Leased/Rented IM20942240802 09/04/2020 09/04/2021 Equipment Ded 260,000 5,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) Miami Shores Village is an additional insured with respect to General Liability if required by written contract. rFRTIFIr'ATF wni 11FR rANr'FI I ATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Miami Shores Village ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2nd Avenue AUTHORIZED REPRESENTATIVE Miami Shores FL 33138 @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25 (2016/03) The ACORD name and logo are registered marks of ACORD r of INTEGRATEDc- O,-Di_Ii .iC�,SOLUTIONS SUBMITTAL COVER LETTER Equipment: JCINORK Solutions Air Handler Date: 8/28/2020 Project: Barry University AHU-10 Replacement Sold To: Thermal Concepts From: INTEGRATED COOLING SOLUTIONS, LLC 10405 NW 371 Terrace, Miami, FL 33178 Contact: Jorge Alvarez Email: jalvarez@integratedcooling.com Phone:305/406.9758 Fax:305/406-9759 NOTES/COMMENTS: • Contractor to review unit electrical data and unit voltage before release. • Contractor to review unit dimensions and clearances before release. • Contractor to confirm coil/door/drain handing before release. RECEIVED BY:. Mcc--1(-2;- 2-r-(�s2 Johnson Controls •••• • • • • •• •• ..•... • • • • •• • .. • •• ta µp2 EQUIPMENT s SUMMARY INTEGRATEDG001-i GSOLUTIONS ITEM A: Outdoor Air Handling; Units Johnson Tag(s) Description Model 3y Controls AHU-10 York/JCI Air Handling Unit XTO Equipment. Summary • 2" Double Wall Foam Insulated Panels • Multi -point door latch (Hinged) : • • • • Factory Mounted VFD Mixing Box/ Filter module • • • Mixing Box Segment • • • 2" MERV8 Flat Filter • • Cooling Coil Module • • • • Stainless Steel Drain Pan • • • Chilled -Water cooling coil with Copper tube/ Aluminum Fins • • • • Electric Heater • • • • 20 kW Electric Heat • • Heater Control Type: Full SCR Controller • • • • Non -Fused Heater Disconnect Switch Supply Fan Segment • Air Foiled Fan • 1" Spring Vibration Isolators • Premium Efficiency ODP Fan Motor • V-belt Drives • 460/3/60 Voltage • •••• •••••• • • NOT INCLUDED: Adapter Curbs, Base Rail, Temperature Controls, Disassembly and Reassembly of Unit, Coating of any kind, Overflow Switch, Control, Shut Off And Balancing Valves, Auxiliary Drain Pan, Damper And Damper Actuators, Smoke Detectors And Fire stats, CO2 Sensors, Freez stat And Alarm, Filter Gauge, External Vibration Isolation, Start Up and any material or labor not specifically described above. S i_LC • 10405 Northwest 37th Terrace, Miami, FL 33178 • 305.406.9758 1 305.406.9759 _:. . WYORKm Job Summary Project Name: 'Barry University AHU-10 UnitTag(s): AHU-10 Quantity: ' 1 Environment: Outdoor Unit Overview Model Cabinet Performance Airflow (CFM) Altitude-(ft) 1Neight (IbS)' XTO-45x63 Solution . 5,000 10LL 2,575 YORK' Solution EnduraTM Air Handling Unit Performance Report • Segment Sequence !�rsF s•... Unit Construction . . .. .. ...... .: . • ��. ����� � rs��a.�`.��3;.. �� �,���- � ���.� Casing=�etd11S u� �"a,s.W� ��='....,^�.�,-�y�..�.,,!:�� � ;, � �!n� ...__ • • •. • Exterior • •or Gauge and Interior Gauge bulkhead G; Segment(s) Thickness (in) Exterior Paint Thickness and Material and Material Material Material STD Ga.. G-90 STD Ga. G-90 FM, CC, EH; FS 2 STD Exterior Paint 2„ Foam Galvanized Galvanized Galvanized , x MRIFF Base Details` d .. _rr Base Floor Segment(s) Gauge and Tread Gauge and Material Paint Paint Insulation Attachment Material Plate FM, CC, EH, FS None None None STD Ga. G-90 None N/A - None Galvanized Unit Electrical Circuit # 1 SupplyFan(s) Circuit Details j Component(s) V/Ph/Hz Full Load Amps (FLA) Minimum Current Maximum Overcurrent Ampacity (MCA), Protection (MOP) Supply Fan Motor Control, Electric Heat 460/3/60 31.6 39.5 40.0 Yes Unit Light Switch_ _ �v Performance Details F� Fan Model Class Size % Wheel % Wheel Quantity Altitude (ft) Total Airflow TSP ' ESP Fan Speed Fan Power Manufacturer Width Diameter (CFM) (in w.g) (in w.g) (RPM) (BHP)' Comefri ATZAF S 15-15 100 100 1 5,000 10 2.76 1.50 1,981 3.62 Project Name:Barry University AHU-10 `� Last Saved: 8/28/2020 11:55:47 AM Unit Folder:AHU-10 Johnson Report Version: 2019.4.24.1156 Unit Tag(s): AHU-10 Controls Software Version: 20.3.6387.5111 Page 1 of 7 WYORKO YORK° Solution EnduraTM Air Handling Unit Performance Report Wheel Drive Type Drive SF Wheel Fan Flow Isolation Total Outlet Max Speed Fan Blade Type Base Material Velocity Power (BHP) w/ Type Material Isolation Type Eficiency (%) (RPM) (ft/s) Drive Loss_ Belt Drive - 1.5 DWDI Airfoil Steel Galvanized Steel None 1" Spring 66.35 2,184 2,900- 3.88 Fixed -Motor Details ti �? Type Manufacturer Motor Power (HP) Motor V/Ph/Hz Quantity Insulation Class Speed Frame Size Full Load Amps (Amps) Efficiency Location (RPM) TEFC WEG 5.0 460/3/60 1 F 1,800 184 6.49 Premium . Left — - - _ At Motor Synchronous Details �a �� T5P (in w.g) Total Air Flow (CMF) Fan Speed (RPM) MotoTotal_ r Correction Factor(%) fan Power (BHP) EficiencY (%) • 2.76 5,000 1,981 89.5 3.62 66.35+• • Water Coil(s) • • r • Performance Details _ ._ ._ .., �. .... - . -z.,_ _1.2.-, .• • ,__. .�,. . �,a-.., • • • • Fluid Coil Rows Fin Spacing TPC EAT (°F) LAT (°F) Airflow FV TMBH SMBH Fluid ' Flow �V71'•+LTVT • Alt. " APD • • Vel WPD Type DB WDB WB (CFM) (ft/min) B (GPM) �'F) (aF) • (ft} • • • • • (FPI) :> ifx/5)• . CC Water 5 14 10, ', 240 154 840 68.0, : 515.'', 518 ; 5000 403. 0.75 34.0 14;O. " $.0 2` • i2 3 10 . • • • Location Connection Connection Rotation Supply Connection Coil Offset (in) MateriaP (degrees) Connection Type (Per Coil) Coil Stack Rack Coil Index= Connection Qty Size (in) CC 0 Left 0 Steel 0 MPT 1 2 Coil # of Coils Face Total Fin Fin Length Coil Face Fin Material Fin Thickness Fin Type Tube Tube Material Tube Wall High Type Height (in) (in) Area (ft=) (in)Diameter (in) Thickness (in) CC 1 Full 35.00 51 > 12.4 AL .010 Corrugated 1/2 Copper .016 Coil Coil Coating Dry Weight (Ibs) Fluid Weight Fluid Volume (ft') Header Material Casing Material Intermediate Drain Fouling Factor (Ibs) Pan Material (hr.ft . F/BTU) CC 234 61 1.0 Copper Galvanized 304 Stainless steel Notes 'Performance is shown for the entire coil bank. Performance is not per coil. zCoil index indicates position in segment. Example: CC-1, index 0; Spacer, index 1; CC-2, index 2 "Johnson Controls suggests using red brass or copper connectors when the coil is to be attached to a copper or brass piping system. All coils are rated with a fouling factor of 0.00000 hr.ft'.°F/BTU unless otherwise noted Ratings are for coils manufactured by Johnson Controls, Inc., 507 E. Michigan St.; Milwaukee WI 53202. Coil DLL Version:7.7d.004 BDW Tube Spacing: 1.25x 1.08 CC[1][0]: This coil is certified in accordance with the AHRI Forced -Circulation Air -Cooling and Air -Heating Coils Certification Program which is based on AHRI Standard 410 within the range of Standard rating conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Project Name:Barry University AHU-10 Last Saved: 8/28/2020 11:55:47 AM Unit Folder:AHU-10 Johnson J Report Version: 2019.4.24.1156 Unit Tag(s): AHU-10 Controls Software Version: 20.3.6387.5111 Page 2 of 7 r3YORK° Drain(s) YORKO Solution EnduraTM Air Handling Unit Performance Report Drain Pan Segment Liner Material Connection Location Liner Coating z CC Stainless Steel - : ,Left None Filter(s) u,...- • • F,Segment Type Depth Filter Loading Media/MERV # of Spares Spare Filter I119dia erlrye 0 jterial • FM Primary,Filter. 4'.' , Side Pleated 30% (MERV 8) 1 Pleated 30%1pp��6$) Galvanized a�... * 3. SFzes� ,�^,���z ,• F ter Geage Detat(s • b� e al in Filter Size W x H 2� Filter Size W x Segment Filter YR Qty 2�d Qty Location • •Yi • • TM• • • • • Type Range (in w.g) • • (in). H(in) ••.•• r• ••••• FM Primary Filter :_ 20x24 4 12x24 2 - •.••••• � '•ees- .••••• •s•••• • • • • •• • •••s•• Damper(s) ' -•••• sees o Detalfs� :. I Total FacesMinimum Damper Blade Actuator Fail Segment Air Path H x W (in) Velocity CFM Allowable CIA Damper Type Model Material (ft/min) CFM Config Orientation Type Position Outside 15.25 x FM 1,049 5,000 Control 100% CD60 Galvanized Parallel Air 45.00 FM Return Air 15.25 x 1,049 5,000 Control 100% CD60 Galvanized Parallel - 45.00 Hood(s) Quantity Total Face Velocity (ft/min) Moisture Eliminator 8750 x FM Outside Air 1 25.1,049 5,000 - Yes , 49.7020 Mr, 77 Segment(s) Location Swing Hinge Location H x W x T (in) View Port Test Spare Thermal Safety Noncontact Safety Port Gasket Break latch Interlock FM Left Outward Upstream Side 39 x 30 x 2 None - - EH Left Outward Upstream Side 39 x 21 x 2 None- FS Left Outward Upstream Side 39 x 18 x 2 None Project Name:Barry University AHU-10 � ',, Last Saved: 8/28/2020 11:55:47 AM Unit Folder:AHU-10 Johnson Report Version: 2019.4.24.1156 Unit Tag(s): AHU-10 Controls Software Version: 20.3.6387.5111 Page 3 of 7 �YORK' Electric Heat YORK° Solution EnduraTM Air Handling Unit Performance Report - �777-7— Details Qty Element Voltage (V) Amperage Draw KW KW Rating Method EAT (°F) LAT (°F) Stages Control Min CFM Type Voltage Required 1 Open 460/480 25.10 20 Standard KW Rating 55.00 67.77 None 24 VAC 1,646 Pilot Lights Control Panel Mounting Control Interlocks Protective Heater Control Screen Type None Standard Differential Pressure Switch and Dry Contact Interlock Outlet Full SCR Controller Disconn11 ect Switch Supply Fusing NEMA Rating Contactor Options Control Panel Options . . = Control Panel Handing Non Fused None NEMA 1 Magnetic 0-10 VDC Left Disconnecting Motor Control _ a -, Details a Input/Output Heat Loss Disconnect RFI/EMI EMC Segment Type MMP V/Ph/Hz Amps* Efficiency (at 100%load) Enclosure Bypass Type Filter ABB •••••• DFS Airmod AYKABB 460/3/60 7.6/7,6 90 % 133 NEMA 3R Cont dos • fused Yes AYK580 Bypass • • • • • • • hap — *Drives are rated for use below 3,000 ft and 104°F. Use Derating Charts in Air -Mod Engineering Guide Form 100.42-5U 42.12) for u e above these ; ""; • •.••.• hn'IltSr •••• • ••••• Storage Temperature: -40°F to 158°F . •. •. • . .. ..;. �' Humidity: MAX 95% RH non -condensing • • .. •,.. .,. �.. Altitude: 3,300 ft. without derate (1% derate for each additional 330 ft.) • • • • •+ • .' Overload Current Rating: 10091ofor 1 minute every 10 minutes. The Class 10 trip rating of the MMP device will not withstand an across -the -line start of a fan and should not be us:d witil VFDs with bypess • circuits. The customer must provide a platform or catwall: for accessing the power -disconnect. *see Copper ConductorsOnly: FS: Contains the following option: Swinging DC Line Choke (Equivalent to 5% Input Line Reactor) Face Velocitv and Static Pressure 311 EMIR Summary X_ MIN Exhaust/Return Airflow Face Velocity Supply Fan Fan Static Segment Description Face Area (sq. ft) Static Pressure (CFM) (ft/min) Pressure (in w.g.) (in w.g.) FM Standard Hood 4.8 5,000 0 0.06 0.00 FM " Bird Screen 4.8 5,000 0 0.10 0.00 FM Opening 4.8 5,000 1,049 0.19 0.00 FM Control Galvanized (CD60) 0.0 5,000 ` 0 0.04 0.00 FM 4" Pleated 30% (MERV 8) 17.3 5,000 289 0.09 0.00 CC Cooling 5 rows 14 fins 12.4 5,000 403 0.75 0.00 EH Electric Heater 0.0 5,000 0 0.03 0.00 FS External Static =User Entered 0.0 5,000 0 150 0.00 Total 2.76 0.00 Project Name:Barry University AHU-10 J Last Saved: 8/28/2020 11:55:47 AM Unit Folder:AHU-10 Johnson ' Report Version: 2019.4.24.1156 Unit Tag(s): AHU-10 Controls Software Version: 20.3.6387.5111 Page 4 of 7 �YORK" Dimensions and Weight YORKO Solution Endura"m Air Handling Unit Performance Report a,; h De ads ;Segment _. Description '; ','_ Lengthy{m) . , Witlth2 (m) , � `:Height,(m),:� Weight (Ibs) FM Filter/ Mixing Box 33 63 45 478 cc le Length Cooling Coil 19 63 45 642' EH Electric Heat 24_ 63 45. 350 FS Supply Fan 61 63 45 1,105 Overall _ „ . ;:j 137 2,575 'The length includes bottom tier segments only 'The width does not include coil connection extensions or door latches that extend, beyond the unit casing. The width does not include the depth` of any pipe chases. • • •••••• •• . . . • •••••• • • • • • • • • Project Name:Barry University AHU-10 , Last Saved: 8/28/2020 11:55:47 AM Unit Folder:AHU-10 Johnson '� Report Version: 2019.4.24.1156 Unit Tag(s): AHU-10 Controls Software Version: 20.3.6387.5111 Page 5 of 7 WYORKm Recommended Trap Height YORK° Solution EnduraTM Air Handling Unit Performance Report s Fan TSP (in Calculated Dimensions (in) Recommended Dimensions (in) Base Rail Segment Applicable Fan w g) Positive or Negative Height (in) H X H+X H H+X Cc Supply Fan 2.76 Negative 3.76 1.88 5.64 4.00 6.00 None Negative Pressure Trap H �t 1" + T.S.P. of downstream fan X=WH Below atmospheric pressure f H Drain ccnacction ..,.., Atmospheric pressure •••••• • ••••% • • • ••••% •••• • ••••• see* • •••••• . • • • . • • • • • . • . •. . • ...... so Formulas and calculations are recommendations only. Contractor shall determine actual dimensions required for each trap based onjobsite conditions, and application requirements. Refer to the`InstaIlation Manual of the 110M for more information.' Statement of Compliance Details - - -- YORK® Solution XT AHU's meet IBC seismic requirements for non -critical equipment (Ip = 1.0) for locations with design spectral response Sds <= 0.43. Units must be rigid mounted. The anchorage of the unit to the ground or building structure needs to be evaluated by and is the responsibility of the engineer of record. Specification of seismic requirements is the responsibility of the project design engineer. If formal certification is required, please contact your sales representative and/or application; engineerfor review. Certain application and site requirements may require additional cost and/or lead time. - Component locations are listed as Segment Hand (Unit Hand): ex. Left (Right). See SubmittalDrawing for additional details Air handling unit parameters vary depending on conditions. Parameters such as airflows, air pressure drops, and coil capacities are shown for design conditions. Project Name:Barry University AHU-10 'J4 Last Saved: 8/28/2020 11:55:47 AM Unit Folder:AHU-10 Johnson :'!' Report Version: 2019.4.24.1156 Unit Tag(s): AHU-10 Controls Software Version: 20.3.6387.5111 Page 6 of 7 WYORKO Shipping Summary YORK° Solution EnduraTM Air Handling Unit Performance Report M� - _ Details Skid Skid Length (in) Skid Height (in) Skid Width (in) (FS EH CC FM) 158 51 Skid Weight (lbs) 84 2,574 F— Total Segment(s) Length —� FE SiddLength W,i Sldddth • • • •••••• •• • • • �•s, s - ••••• - - Notes �- - ••f �.. •..•_ .�7. • ; _ Skid Width: Total width of the shipping skid, including any items that may extend beyond the cabinet (this includes any door handles, coin ; •. •. ; connections, drain connections, lifting lugs, mounted pipe chases, electrical/control components, tie. -down bracketsps`ide dampers);...;. Skid Height: Total height of the shipping skid, including any items that may extend beyond the cabinet (this includes any base -rails, sipping wood- blocks, roof peak, discharge flanges, mounted gas -furnace flue pipes). ";"; ; .". 00000 Skid Length: Total length of the shipping skid, including an items that may `extend beyond the cabinet this includes an mounted rain) oods, !� g PP� g g Y� Y Y ( Y """ discharge flanges,tie-down brackets, shipping wood -blocks, front dampers, split connectors, electrical/control comppne'ry 11)utrigging Otensions, • • • isolation dampers, inlet baskets). 0000 Special Quote(s) Project Nanne:Barry University AHU-10 !� Last Saved: 8/28/2020 11:55:47 AM Unit Folder:AHU-10 Johnson (J Report Version: 2019.4.24.1156 Unit Tag(s): AHU-10 Controls Software Version: 20.3.6387.5111 Page 7 of 7 Johnson Solution XT'Fan Rating Curve Un it Tag. PADd-el: S" Fan Type C lass: Size. Size.PrqjectNa-me B: arry UlIffiversity AHU-10 XTOE45X,63; FS, AF S 15-15 15.flffl II /, lS1I .l- SX-V OpratIPy.-Unt, 14AM- Dmwl�pe:: DMW,-T:bnj! T—M---- FON'T CTm 50cc, 13M-ac[w T3P1[3n),H2Dj;1:: 22C AlfiftUdel Itit SHP-, 3A2 12 r 7 r ---- r ---- 0 21 1- 4 ---- --2 ------ T - - - - --- --- ------- an Limit rZ ----------%--------- iF Mx RPW 2M &00 --------- Mm. TSP:: I--Ar, SAO - ------ ------- Cabinet Unifts - U) TO --------------- OL L-- .5 4.90 - 3.50 3.0 ----------- L% J 15D DAID -4 -D 6; 1.2 121 24 4 -'916; M 311 361 42� 7 3a (2. IN 114 ZD Pfinted: 0&2 § 14:30kiY-5 040 Flow" -'ate I S.Ul iaflrl m R. gpCuirffo U - Fags I of T UNIT CONSTRUCTION ModW SWwo.,XT04 3 C—k.&J.:OWE-r MW-tA.WM.n aphl UnMThIpM: 2,9d •u IN-70%) �, ELM Rw FM YIM 15sphla0�tw.e.d NOTES pain ap. p: u eam.ntl-9uW W tlln bWW. Ww9,.W Ru.h wi1hbW1an fixes" Mhrp Irommm.n ad lar. R . aWp. .P.- tlm -c-. P.mro -drab. pap of No MIL A mlNmwCrou.m..wtlplM MIN W. mm mutl M PmFM.d.n om Wd. WOm un9rornnronp/ •. oW-S- C.01.1.rr-paalbN m a 11 mmm.u-. W.n.l.Wdw Mn-.nd nWw-n com.W-L .CN and ownhms, mW-pa•d.."rotlmy Fd.O. hW M.-,-lean-Wbm, nM Mod" Plp. W—,AM6fi1d-P.rIFA11LI—III.pPlmbro,) bw N-h1 adap wmNy tla bw.P.p w1ld.am-bfartla wk Cu W TI INmF mny. W r4 beyondC W In.t dlm.mpw hRJu el;d-haWl-, 91M.w1WI-, W-WA roN .lu TM mall eNl ro to dilmd-.ddnbml1N' Pa shipping split do p ndetlontl paMUnp ad .PN nrn.etlnnnnen R ' Phwh.Mlsc-W a •pw pN l.a.pm PIPING CONNECTIONS UNAM Tan Pn anlaW NW Rdw CC MPT UN113.11R.1 T T PLAN VIEW FS EH FM DrvW pan collnacllan dne 7 7N' MPT ECM 40 24 ConIMlWblln W Lao Side of win SECTION UST 1 i --� -- � I r---- I LECT pfltl•IIPII Fk. Mpa Bo. VFo I I if I I I I IF �b'i') ` CC C-ll Cal Pac I I I H I I 1 I `y �a� 1` (a]. 25.66 EH EI.Mn H.W r i ii i i yT i FS Su F.-15.15AF IB.tfi' 95 I LL r11yI�1 I I I I I I I I I �di 17.0 I I o __ __ 137 • i • • • • ` 2� • -NOTE: MAX HEIGHT I 1`"-MLE`•^;11 TO PEAK OF SLOPED ROOF • • • • • • • • •• ••• •• • • • •• ELEVATION VIEW Pmj cl Name: Barry University AHU-10 Sold To: • "bateP:8021*1202011i§SM • • • Serial Number.PRODUCT DRAWING Loaall m CUet Purrh Ordedk. • • •. SO Database Number. LSOLUTION XT AIR HANDLING UNIT DETAIL Engineer. COntMCW. ON920243 • • • UNIT • i YORKvraks Release: Jo nson�� �INO7 FOR CONSTRUCTION ForMODEL: Solutlon�)C!7045II63 t��r TAG;AHU-10 - S et 1•• •TITS • • • • DW9: Locmetlun: Control$ 19.54III�I��j�)�A^II � OA7 25.52 III ;lil I I I I I I 1 1 r--_ i i I 1 11 1 I � ;j I I I II I I 1 11 1 L_LL_I 1 I j r�JF�Fm I 111112 i •d++41i1�� I I��I I 111112 I IIIII i� I11 � II II II allll II II. II Inl 'B II l �1111 n I11 II II III 11 II Illr I1111 II II.I � III -_•I I6 63.7 I.fiS 5.6 I I I I I I I I -1 -1 /5T5 17.73 --78.97 ••• • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • UNIT CONSTRUCTION - Madut: paWbn4Tf0ALQ Cnnbuuteu.: Outdaw Nun, UMIW4M1X T,574 •s. (N•104) PJW -i-11 ELAM pre�l, Fnn VIEW pns91 *..al 4 NOTES 3 an apsn g: Duct wwrd . b.b uYl •s buns d wX, nd ff wh nmbbwdbnrn. bWb /ar.N u duties. up- rn n amn n Ib aw .p.MhandwllwupubddounXA •Wml.a Wvnw purlbtln WIN dtln IaISarW b pwrldsd n wr ids dIM unX/srnw.rap tln wffwhn onXl.dwnsponutbi for Psad b awsrallow dull utunlwl bear W Wrrwl nil wnrdbas. w.n r qs ed wnbnp, natty - caurol radar halary pwbups wnbd ban, ran wlansnass. M'u hood" PIP ,hunkANI p dump.rlFAMLkwapluppllwblQ bw o4 • b ads b wnwy. bus up— ngsbmsW lartla nN C wburrW udlld buY.ld wMnadNNautan Inabdlnp: dwr hndluu, Spb.dlchn, d.dd W bun .suds Tb waru nhbnythk kWr w ddd"1Mw shipping split dw w.ddNwd pnbGng nd upM wnwrllas hu t— ffbrdoutdaawraaKrI • •Iw law t PIPING CONNECTIONS gn.rdrra •• ••• •• • • • Coil Connections •• knut 7 NW pin Cc MPT Lsff 1Su 1bt i Y Owb pan aasnabn utw 1 1W C—uctbM M L.ff Sid. d udl MPT SCN 40 SECTION LIST VICT UE9CAp11ffX FY aw cc C.dl cuff INt EYutdc Nsut FS Fn•1Z15M PRODUCT DRAWING SOLUTION XT COIL CONNECTION DETAIL SoluUon-)C'rO-45X63 NOT FOR CONSTRUCTION Project Name: Barry University ANU-10 Location: Engineer. FGr.MODEL, ��r Sold To: • • • Cust Purch Order#-. ContractM: ON920.2143 • ale: 02011. Verslor� 6orm N�: • �. Seale: NITS /03 • • • • • • • • • Serial Number. SO Database Number. YORKworks Release: . Location: Johnson Controls �•0 ,l0 .• TAGT AH U— 1 0 SW Its L G • • • I I I 7.08 ; 1 i i I I I I I 1 1 1 I I I i i I I I I ` I ; ) o.B4 TYP BB.t6 83.75 10025 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • DETAILA SCALE 1l2 \ TYPICAL ROOFING FELT A 2" X NAIL CURB INSULATION ROOF ROOF CANT-\ INSULATION STRIP CURB DECKING J .y ROOF STRUCTURE TYPE"A" PING /' 2"X4" FELT �._/ NAILER ROOF CURB DRAWING AND DETAILS (NOT TO SCALE) CURB ILLUSTRATION FOR REFERENCE ONLY. CURB SUPPLIED BY OTHERS. CURB ROOF CANT INSULATION STRIP ROOF DECKING ROOF HARDWOOD OR STEEL STRUCTURE SHIMS BETWEEN ROOF DECKING AND TYPE"B" SUPPORT STRUCTURE ROOFING 2" X 4" FELT NAILER 2 TYP. I I I I 1 9.54 I I I I I I I I I I 1 I I I I I I L------ J I I I 1 I I 45 62.1 !8.08 I I 8.56 17.29 16.87 15.25 5.06 I- 136.12 UNIT WEIGHT 2574 Lbs. CURB WEIGHT Lbs. PLAN VIEW Right 4 Rear Unit Front (supply) a Hand (Return) Left AIR CURB ROOF CN'IT 311e"THICK INSULATION STRIP BEARING PLATE UW T WIDTH -e3 ROOF UNFTLENGTH-131 DECKING HARDWOOD OR STEEL OF STRUCTURE UNIT WALL SHIMS BETWEEN BASERAIL ROOF DECKING AND TYPE "C" SUPPORT STRUCTURE - GASKET, OPEN CELL RACEWAY 0.76' THK X 1.25• NOTES: 1. CERTAIN ITEMS MAY EXTEND BEYOND CABINET DIMENSIONS. so (ax. COIL CONNECTIONS, DOOR HANDLES, MOUNTING FEET, ETC.) • • • • • • • • 2. ROOF CURB MUST BE INSTALLED SQUARE AND LEVEL SPLICES OR CROSS BRACES WITHIN 10.00" OF CURB REST • 1.7YP �437�Typ• • • 3. CROSS BRACES AS REWD.: NO • • • CURB YVID�1 : • : • EITHER END OF PIPE CHASE. CROSS BRACING CAN BE LOCATED BETWEEN PIPE CHASE ENDS. 2X4NAILER � .121 CURB LE1-136 • • • 20•TYP • ` • •• CURB HEIGHT To BE DETERMINED BY CURB SUPPUER „I SECTION VIEW 200TYP PRODUCT D RAW I N G Project Name: Barry University AHU-10 • � e6 Tlu • • • • • eC11�1•,Purch Oar#: : • • • • Date: 8/28/2020 11:55:52 Version: 010 SOLUTION XTAIR HANDLING ROOF CURB Location: Engineer. Contract#: ON920243 � :• Form No.: Johnson MODEL: Solution-XTO-45x63 Contractor: UNIT - heet 3 Dwg. Lev.: 5/03 Dw Scale: NTS Controls NOT FOR CONSTRUCTION For. •Ti�G: •AKIJ-a . 'ORKworks Verslon: 20.03e BralMag Generator vennon : u1:UU:Tsuue • • • • • • • • • • • • • • • • • • • ••• • • 0 ••• 0 0 .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. PrOJSM Name: Barry UnNeraltyAHU-10 Sold To: - - - - - Date: e1202011: 52 • Serial Number.PRODUCT PRODUCT DRAWING Location: Cuet PUrCh Order# •• ;• Vemk : • . SO Database Number L YORK Custom Field Wiring Engineer. Contracht ON920243 . . • • orm Yo.: 100.09-E61 • YORKworks Release: �OI InsOn ` MODEL: FOR CONSTRUCTION For. NOTTITA,: AH U-10 - Shgbt 1. • • . Dwg. tkefa'Nrs • • • • Locati DZ: Na111eo1n: Controls Dwg. rpalwYKnMp: alAL en�1Me�MnIMMnbn:01:o0:taxr • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • .. •• • • • • • • • • • • • DISC ti Lt n _ O ILI FBI 40°4 Lt 11.I SUPPLY FAN MOTOR n i W CONTROLLER oy E u to u u FIM RETURNIE]CHAUST FAN MOTOR CONTROLLER OR Au)aLUM EQUIPMENT T' i-_-_ --------------------------------------------------------- PAm tl FBS I 1 AUXILWW EQUIPMENT j Kt - tmv---- !!j, I I 1 I I OPTIONAL] �ccluue 1 J� NGTER I Ea ADMeONN. I - YaMWRousAAN- J NOTES: •• ••• • • • • • •• • • • • • 4'-IERM•IAL IDINT • • • • • O. -Omew Dw (BYOTNERS) • • • • • •t-WBIE•ERTRANW.MERL.ELPERUOLTAOE. • • • • • • • IS AWLLWV EOIMMENT- MAY BE DEFINED AS FOLLOWS ELECTRIC HEAT OAS FIRED HEAT ENERGY WHEEL MOTOR CONTROLLER Project Name: Barry University AHU-10 Sdd To: • • • • Da .i 020 . 2 Serial Number. I'1 �I PRODUCT DRAWING Location: Cuat Puroh OrdeAF • • • • Verslyc ; SQ Database Number. `�J YORK Custom Field Wiring Engineer. ConiradM. ON920243 • • • • • Form o.:• 1QQ.09-E�it • YORKworks Release: JOI1nSOi� MODEL: Contractor. .1 ♦ p Dwg• 1 3 • • • • DW9• Name: COfltf'OIS NOT FOR CONSTRUCTION For. TAG: AH U- 1 O S L V • • tale: NTS • D . Location: rolec.wtmw: m.oa o...aw a.,e,.mrv.ew:oEoonroM • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • — all u •.coNNeerrweo NeW. WIRING CONTINUED ICPRCN) FROM MAIN DISCONNECT SWITCH NOTe VFD cuerwm xeouuMn TO PRowe YPANSPG NECAMO LOWL MIILTN -A OMON:UNEmMM@ 010 ae0 IMNRALENTTOPI%WIHPTE LNER ACrOR) � IOPIIONI FORMiG0110 FNYMONIerrr RH e eNAuwlevumRONNI N9eeL1@. N aI-NYeANsar » O� O � u�e»nyrcurtNbxVaw�iwNY-�. wN,eeA O o ®a vaxe wRN.RWNNcnNNse m w O » � •� » DETAILA �Pm.« e®mN«I p�._I .Nw,IW.-N..e..eTWNe.ewe,Neoee.e«,.oRee. » O O O Jff IO[TFJrNAL SPEED REFERENCE «NN«R .Peen � � �. •• « w,PWePuwN voe .N.. ,sue'_ " .w_1 AWe.Mr.NowWWo,oR �» o . . • • • • • • • • • FAULT RELAY OUTPUT SIGNAL OUTPUT CONTACT • • • • • • • • • • �.ewm �.�..r«^vq O �n om ❑-TERMINALPOINT • • • • 0.0 RSI • • eWesRvar.n.N«wu emne eleerYve ° w� O1Nie Nurw«Iw- ♦ -REMOTE—ACEIMOTNE• • • • • • •• • • «ere nwNnneo«Wm ❑��.�e w�NeW+.yennr W ❑�� w�iene.ee -oPrloxnLPANELcoMPONExTe :NRE ER TR -WIRE PERTMNEFORNeR LANELPER VOLTAGE eewe,«vu eeewWw vwc,eweu •URE YINIYUM TE•C COPPER WIRE ONLY Project Name: Barry University AHU-10 Sold To: • • Date: �I28I . 11:5fit. Serial Number. ',�'(� PRODUCT DRAWING Location: Cust Purch Order#: . . .• Verslat SQ Database Number. Q,J YORK Custom Field Wiring Engineer. ConbaCW: ON920243 • • • • • onn No.: 100.09-E01 • YORKworls Release: Johnson MODEL: Contractor. T 1 ,EL • • . l� 12/03 • • • • DWg. Name: Controls NOT FOR CONSTRUCTION For. TAG: AH U-10 � Sneit Z • • . &ale: NTS • • . Location: twowee,e�xev o:...pa.nel.Nrvr.N.:Ma yxrr • • • • • • • • • • • • ••• • • • ••• • • Sea Coast Curb Adapters, LLC 2600 INDUSTRIAL AVENUE 3 FT. PIERCE, F10RIDA 34946 For Seacoasts ��eided, i6 ` Adapters Only Garr e, "x2" x16 'vNe{deder�meter� fgpic,A Curb Wall retail M to Adapter; # 14 zinc plated, self tappinq sheet metal 5crew5 @ 4" OL Adapter to 1x, Curb: # 14 zinc plated, self tappinq sheet metal screws @ 4" OL, Job, 0 ',J1 �xistiq CL-b'-1 fastener Petail Notes: I • �aster�crs shall p�r>✓-��raEe t�rr� urb a��:r crt{ a m r m um rt 3 ti^reacis. 4• Akc atc '1r„WlYt crt.. 136 LAa -&a4 ,s mac% sus. +,'�. e,, ( 2 7arre cPa+L of astener< r :juue�? x', A,+r.,� ,IT!er'� i5 r�;" c�r�= ac�, }i s {"n_ �'Tu $cur'.• aca�rr-,r >G iM!5tir4� �:rh �r^h.�, _xh tr, -rvr attut Pt!4Y:m 3' 'Ti_-T5• Benchmark Engineering E 1 % & 1�5C i -I0 of the Treasure Coast LLC 8o6 Delaware Ave. --at 11, hp. C �� , jklax it Fort Pierce, FL 3495o ;ell ... Inspector Shall Cc3n#�rm:5eacq-�• Packard Affiod F"*'to Approval A C b 13� ► 2 �, \NX0MUT r'h; f�i,, CNN - k8 /s ,N •' G��s Stuart Office 2497 SE Dixie Highway Stuart, Florida 34997 O: 772.220.2365 F: 772.220.2273 �VA� w.THERMAI HVAC • Refrigeration • Ductwork CAC039621 CSC046951 CGCA07936 Main Office 2201 College Avenue Davie, Florida 33317 O: 954.472.4465 F: 954.370.6410 Gulf Coast Office 8270 Woodland Center Blvd. Tampa, Florida 33614 O: 727.914.8530 F: 727.914.8362 DATE: August 6, 2020 CLIENT: PROPOSAL: 00032528 Barry University Barry University 11300 Ne 2nd Ave ATTN: FACILITIES MANAGER 11300 Ne 2nd Ave Miami Shores, Fl 33161 Miami Shores, FI 33161 0 0 0: • Phone: 305-986-4751 000 • •• Fax: CONTACT: Al Halliday... ; •' • • • ....;. .. . •...•• We propose hereby to furnish material and labor, complete in accordance with specifications Dgl4w for the Slim of . . : •' • • ; Forty -Five. Thousand Four Hundred Fifteen And 87/100 Dollars. • • • • • 0 : • • • • • 00... •••r.• . •• .. 91090 • BID#32528 •' " •":' •""' • Provide labor and material to replace RTU#10 located on the roof of the LanQon'b4ilding. . ....:. . . • Lock out and tag out existing electrical to old unit and disconnect from unit. ; • • • • • 000000 • Provide crane to remove old unit from existing roof curb, set new curb adaptor on existift 0 "&b and set • new York RTU model# XTO. • Reconnect to existing electrical. • Connect chill water piping to new chill water RTU. • 2" double wall foam insulated panels. • Installation of thermometers, gauges and modulating Belimo control valve. • Insulate piping with 2" thick foamglass insulation and finish with aluminum jacketing. • Unit comes with factory mounted VFD. • Stainless steel drain pan. • Electrical heat 20 KW. • Dispose of old unit off site. • Mechanical Permit cost and inspection included. • Work to be done during normal working hours Monday through Friday. TOTAL BID: (Forty -Five Thousand Four Hundred Fifteen And 87/100 Dollars) $45,415.87 Payment to be made as follows: Net 30 Days THERMAL STANDARD TERMS, CONDITIONS AND EXCLUSIONS ARE PART OF THIS PROPOSAL. Customer Initial Thermal Concepts, Inc. Proposal Paee 2 of 4 Acceptance of Proposal This proposal may be withdrawn if not accepted by September 30, 2020. The above prices, specifications and conditions are satisfactory and are hereby D4 Se� accepted. You are authorized to do the work as specified. Payment will be made as Account Manager stated above. Date of Acceptance Signature Printed Name • •••• • ••••• •••••• • •• ••••• •• •• •••• •••••• • • • •• • •••••• • Customer Initial