Loading...
MC-11-20-2658, 1138 NE 99th StMiami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Parcel Number 1138 NE 99TH ST, Miami Shores, FL 33138 1132050180140 Contacts JAMILLE DECKER ALIAMRD DECKER Owner DIRECT AIR CONDITIONING INC Contractor ALIAMRD JUAN SOTOLONGO Other: 3057515594 Business: 3055962666 erwin@directac123.com Description: a/c change out Valuation: $ 12,500.00 Inspection Requests: Total Sq Feet: 0.00 € Fees Amount Application Fee - Other $50.00 CCF $7.80 DBPR Fee $6.56 DCA Fee $4.38 Education Surcharge $2.60 Permit Fee $387.50 Scanning Fee $9.00 Technology Fee $10.94 Total: $478.78 Payments Date Paid Amt Paid Total Fees $478.78 Credit Card 12/03/2020 $478.78 Amount Due: $0.00 Applicant Copy For Inspections, Call (305) 762-4949 or Log on at https:/Ibldg.miamishoresvillage.com/cap/. Requests must be received by 3pm for following day inspections. NOTICE: In addition to the requirements of this permit, there may be AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER additional restrictions applicable to this property that may be found in the GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, public records of this county. STATE AGENCIES, OR FEDERAL AGENCIES. December 03, 2020 Page 1 of 2 Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Parcel Number 1138 NE 99TH ST, Miami Shores, FL 33138 1132050180140 Contacts JAMILLE DECKER ALIAMRD DECKER Owner DIRECT AIR CONDITIONING INC Contractor ALIAMRD JUAN SOTOLONGO Other: 3057515594 Business: 3055962666 erwin@directac123.com ection Requests: Description: a/c change out Valuation: $ 12,500.00 Ins y, • .w Total Scl Feet: 0.00 H ....j � I Fees Amount Application Fee - Other $50.00 CCF $7.80 DBPR Fee $6.56 DCA Fee $4.38 Education Surcharge $2.60 Permit Fee $387.50 Scanning Fee $9.00 Technology Fee $10.94 Total: $478.78 Building Department Copy Payments Date Paid Amt Paid Total Fees $478.78 Credit Card 12/03/2020 $478.78 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, rRy a 90A, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, RQDFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and II work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contr r to o the v�r "tated. Authorized Signature: Owner / Applicant / Contractor / Agent December 03, 2020 Date Page 2 of 2 RECEIVED 1 120(wz' Miami Shores Village M(v Building Department �Y._ 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 {� FBC 20 17�' u I BUILDING Master Permit No. Mi_' PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING KMECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF [:]CANCELLATION ❑ SHOP t CONTRACTOR DRAWINGS JOB ADDRESS: 1'✓2 S AL �� W uA� City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: �'� /� (7 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: cam, OWNER: Name (Fee Simple Titleholder): ` "At k 1 Q, U'Y s Phone#: Address: ,/� 3 t A&1 - J City: ' "l�Ll, k State: Zip: �1 d Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: xyt—o ((S\Adl�W\_Phone#:' J—! 6 — Z U 6 V Address: S W City: V\.&.t a (&kT Qualifier Name: T\ V G Y ` S State Certification or Registration #: DESIGNER- Architect/Engineer: Zip: �3l one#: Certificate of Competency #: one#: Address: City: State: Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: ❑ Addition Alteration ❑ New ❑ Repair/Replace Specify color of color thru tile:, Submittal Fee $ Scanning Fee $ Permit Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ _ Zip: ❑ Demolition CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ U (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with alF applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceedin 2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochur ill, be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of co ent rriu be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued'' In shy a ey(c f s posted notice, the inspe ' n l not be approvellyqd%reinspection fee will be charged. i Signatu or AGENT The foregoing instrume t his ackr,,oAwI dged before �m/e�this day of C�'� A Y� 20 iT" , by ;who is personally known to me or who has produced as identification and who did take an oath. NOTARY PU6LIC: Signature -14 CO The foregoing instrument was a,El nowledged before me this V da of 20 _ by who is personally known to me or who has produced identification and who did take an oath. NOTARY Sign: I I I Sign: Print: Print: Seal: ,, " _ JOSe GONZAL=Z Seal: No:a'yP,blic-5c_:<cf=o _ Corr . o r,r, �o rT tx C,: c. Oc: 2_. ..__. APPROVED BY — iner V\�J Str ural Review JOS=GONZAL=Z ��. �`�` Notary?❑��c-S:a-z of -'e,:'da Mv Corr Gx i i e.;'<i F�J Zoning Clerk (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33188 Tel: (305) 795.2204 Fax:(305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must' be on its own data sheet. Multiple units on single sheets are notacceptable.acceptable. Job Address (where the work is being done): '1 1 3 S ) 5 �� City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED Change disconnecting means: YES ❑ NO ❑ ARHI Sheet Attached: YES ❑ NO ❑ Contract Attached: YES ❑ UNIT NG REPLACED DATA NEW UNIT MANUFACTURER p Ll cw AHU or PKG. UNIT MODEL# M,1a L • COND. UNIT MODEL # KW HEAT NOM TONS AHU _ CU 22 a PKG 1) M.C.A AHU 5 pCU.32.q PKG AHU CU - PKG 2) M.O.P AHU CU Q PKG AHU CU PKG 3) VOLTS AHU CU PKG PKG UNIT / / PKG UNIT EER/SEER YES NO REPLACING DUCTS YES NO YES NO REPLACING THERMOSTAT ES NO YES NO NEW 4"CONCRETE SLAB YES NO NEW ROOF STAND YES YES NO NEW RETURN PLENUM BOX YES NO 1. Minimum Circuit Ampacity (Wire Size): ICJ 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means:. Contractor's Compariy Name: '( i State Certificate or Registrati o 't Certificate of Competency No. f Signature Date: (Revised02/24/2014) r Certificate of Product Ratings AHRI Certified Reference Number: 201924711 Date : 07-02-2018 Model Status : Active AHRI Type: RCU-A-CB Series: DAVE LENNOX SIGNATURE XC25 SERIES Outdoor Unit Brand Name: LENNOX Outdoor Unit Model Number (Condenser or Single Package) : XC25-048-230-** Indoor Unit Model Number (Evaporator and/or Air Handler) : CBA38MV-048-230*+TDR Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this LENNOX product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 48000 SEER: 21.00 EER (A2) - Single or High Stage (95F) : 13.00 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being prod uced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the Drevious (i.e. WAS) ratina. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2018Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 131750091002793809 RAISED seal below authenticates original copies. Photo copies are not acceptable. PREMIER STR_VUPAj_ CERT OF AUTHORIZATION291 13 DESIGN - INVESTIGATE - INSPECT 2333 TUSCARORA TRAIL, MAITLAND, FL 32751 PHONE: 407-227-741 6 WWW.PREMIER-STRUCTURAL.COM PROJECT NAME: LENNOX RESIDENTIAL UNITS — WIND LOAD COMPLIANCE PER 2017 FBC DATE: 08/26/2019 TO: MR. TOM BRITTAIN BRAND/PRODUCT MANAGER — COOLING LENNOX INTERNATIONAL RE: RESIDENTIAL UNITS - 2017 FLORIDA BUILDING CODE WIND LOAD CALCULATIONS FOR NON - ROOFTOP INSTALLATIONS Mr. Brittain, Per your request, we have analyzed the complete Lennox Residential Line of units. Our analysis was performed in accordance with the 2017 Florida Building Code using the following Wind Design Criteria: • Ultimate Wind Speed = 186 miles per hour • Risk Categories = III and IV • Wind Exposures = C and D • Non -Roof Install Height of up to 10 feet above ground As a result, we have concluded that only the 39.5inch long by 35.5inch wide cabinet LENNOX ELITE and DAVE LENNOX SIGNATURE SERIES require additional screws for non -rooftop installations of up to 10 feet above ground. (Reference page 6 for model numbers) All other residential units may be installed as manufactured. (Reference pages 2 to 5 for model numbers) Please note that our analysis and results pertain only to the LENNOX unit itself and its ability to maintain structural and panel integrity under severe wind events. The attachment of the units to the building structure and the adequacy of the underlying building structure are not our responsibility and shall be determined by others (i.e. building engineer of record or third party engineer). If there are any questions please feel free to contact me. Kharl A. Rodriguez, PE Florida PE# 60239 LENNOX RESIDENTIAL UNITS - 2017 FLORIDA BUILDING CODE PREMIER STRUCTURAL ENGINEERING CAN 29113 THE FOLLOWING UNITS MAY BE USED AT NON -ROOFTOP INSTALLATIONS OF UP TO 10 FEET ABOVE GROUND TWI HOUT PANEL MODIFCATIONS. Dimensions Product Line Base Size Brand Coil Protection Louver Design Model Number Length Width Height (inches) (Inches) (Inches) Lennox Horz. 13ACX-018-230-17, -18 Lennox Horz. 13ACX-024-230-19, -20 Lennox Vertical 4AC131_18P-7A, -8A 24.25 24.25 25.25 Lennox Vertical 4AC13L24P-7A, -8A Allied Vertical 4AC13L18P-7,8 Allied Vertical 4AC13L24P-7,8 Lennox Horz. 13ACX-030-230-18, -19 Lennox Horz. 13ACX-036-230-17, -18 Lennox Horz. 14ACX-018-230A" Lennox Horz. 14ACXS018-230A'" Small Lennox Vertical 4AC13L30P-7A, -8A Lennox Vertical 4AC13L36P-7A, -8A 24.25 24.25 29.25 Lennox Vertical 4AC14L18P-6A Lennox Vertical 4AC14LS18P-6A Allied Vertical 4AC13L30P-7,8 Allied Vertical 4AC13L36P-7,8 Allied Vertical 4AC14L18P-6,7/4AC14RL18P-6,7 Lennox Horz. 13HPX-018-230-17, -19 Lennox Horz. 13HPX-024-230-17, -19 24.25 24.25 33.25 Lennox Vertical 4HP13L18P-7A Lennox Vertical 4HP13L24P-7A Lennox Horz 13ACX-042-230-17, -18 Lennox Horz. 13ACX-060-230-17, -18 Lennox Horz. 13HPX-030-230-17, -19 Lennox Horz. 14ACX-024-230A" Lennox Horz 14ACXS024-230A" Lennox Horz. 14HPX-018-230-19 Lennox Vertical 4AC13L42P-7A, -8A Lennox Vertical 4AC13L60P-7A, -8A 28.25 28.25 29.25 Lennox Vertical 4AC14L24P-6A 16ACX-036 Lennox Vertical 4AC14SL24P-6A Lennox Vertical 4HP13L30P-7A Lennox Vertical 4HP14L18P-7A Allied Vertical 4AC13L42P-7,8 Allied Vertical 4AC13L60P-7,8 Allied Vertical 4AC 14L24P-6, 7/4AC 14 RL24 P-6, 7 Lennox Horz. 13ACX-048-230-19, -20 Lennox Horz. 13HPX-048-230-17, -19 Lennox Horz. 14HPX-036-230-19 Lennox Horz. 14ACX-042-230A"' Lennox Horz. 14ACXSO42-230A" Lennox Vertical 4AC13L48P-7A, -8A Lennox Vertical 4AC14L42P-6A, -7A 28.25 28.25 33.25 Lennox Vertical 4AC14LS42P-6A, -7A Lennox Vertical 4AC14L48P-6A, -7A Lennox Louver Vertical 4HP13L48P-7A Lennox Vertical 4HP14L36P-8A Allied Vertical 4AC14L42P-6,7 Allied Vertical 4AC 14RL42P-6, 7 Allied Vertical 4AC14L48P-6,7 Medium Lennox Horz 13HPX-036-230-17, -19 Lennox Horz. 13HPX-060-230-17, -19 Lennox Horz. 14ACX-030-230A" 16ACX-048 Lennox Horz. 14ACXS030-230A" Lennox Horz. 14ACX-036-230A" Lennox Horz. 14ACXS036-230A" Lennox Horz 14ACX-041-230-03 Lennox Horz. 14ACX-048-230-14 Lennox Horz. 14HPX-018-23OA20 Lennox Horz. 14HPX-024-230-19 Lennox Horz. 14HPX-030-230-19 Lennox Vertical 4AC 14L30P-6A Lennox Vertical 4AC14136136A, -7A Lennox Vertical 4AC14LS30P-6A 28.25 28,25 37.25 Lennox Vertical 4AC14LS36P6A, -7A Lennox Vertical 4AC14L48P-8A Lennox Vertical 4HP13L36P-7A Lennox Vertical 4HP13L60P-7A Lennox Vertical 4HP14L18P-8A Lennox Vertical 4HP14L124-8A Lennox Vertical 4HP141-3013-8A Allied Vertical 4AC 14 L30P-6, 7 Allied Vertical 4AC14RL30P-6,7 Allied Vertical 4AC14L36P-6,7 Allied Vertical 4AC 14 RL36P-6, 7 Allied Vertical 4AC14L41P-6,7 Allied Vertical 4AC14L47P-6/7 Lennox Horz. 13HPX-042-230-17, -19 28.25 28.25 43.25 Lennox Vertical 4HP13L42P-7A 16ACX-024 Lennox Horz 14ACX-047-230-03 Merit/Aire- Lennox Horz. 14ACX-060-230-11, -14 32.25 32.25 33.25 Lennox Vertical 4AC141_60P-6A,7A Flo/Allied Allied Vertical 4AC14L60P-6,7 Lennox Horz. 14ACX-059-230-04 PAGE 2OF6 LENNOX RESIDENTIAL UNITS -2017 FLORIDA BUILDING CODE PREMIER STRUCTURAL ENGINEERING CA* 21111 THE FOLLOWING UNITS MAY BE USED AT RON-ROOFTOP INSTALLATIONS OF UP TO 10 FEET ABOVE GROUND WITHOUT PANEL MODIFCATIONS. Dimensions Product Line Base Size Brand Coil Protection Louver Design Model Number Length Width Height (inches) (Inches) (Inches) Lennox Horz. 14HPX-042-230-19 Large Lennox Horz. 14HPX-048-230-19 32.25 32.25 37.25 Lennox Vertical 4HP14142P-8A Lennox Vertical 4HP14L48P-8A Allied Vertical 4AC14L59P-6,7 Lennox Horz. 14HPX-060-230-19 16ACX-060 32.25 32.25 43.25 Lennox Vertical 4HP14L60P-8A ["'Imox 1SACD-Mu )30-15 ["[In- x 1 ^U) 024 `. ,0-1ti 24.25 24.25 25.25 Allied 4AC13618P-7,8 Allied 4AC13B24P-7,8 (-f :,1111Gx IlAiiS(i`+4 C`J 4.;Y 1SA b"4N' H y Small i.:^,:; 24.25 24.25 29.25 Allied 4AC13 B30P-7, 8 Allied 4AC13B36P-7,8 Allied 4AC141318P-6,7/4AC14R618P-6,7 L P.fIIlJ'; 13ACD 036 1,30-17 24.25 24.25 33.25 mox T1 V,(;3 )S4ra44G, ir�ar-iriC -� 13ACD-042-230 7 �:Ill :iY Ill I ; ji4 r14. ii IN I 28.25 28.25 29.25 i.'iin�)r 11 f / sCilli�i 1 'G Allied 4AC13642P-7,8 Allied 4AC131361 Allied 4AC14B24 P-6, 7/4AC 14 RB24P-6, 7 Allied 4HP14618P-8' Allied 4HP14B24P-7' I-"(Innr. 13ACD 060 230 Allied 4AC14B42P-6,7/4AC14R642P-6,7 Allied 4AC14B48P-6,7 (�,Ilirnx 1'ACxS1 N cl.I I `I111nq; 1 1 }��1e`i.1 i;'r �i u1 ;-< 28.25 28.25 33.25 13) Wire Guard Medium � 'a 1 4) _J1 11 IIN14(� U[ Il f"x }F I �H4�143`r i_ON ox. 13ACD-048-230-1 7 Allied 4AC14B30P-6,7/4AC14R630P-6.7 Allied 4AC14B36P-6,7/4AC14RB36P-6,7 ci .i:Os. I�-z;S4N<14Y �,I:e: 1 a1PJ1-4: 4P-145Y 28.25 28.25 37.25 _�nroi It OS4PIi,4; 11A'I2 ,lN4�Y 28.25 28.25 43.25 11 /\ I1I '_ennor, if ,-1; 117;a-I ;iG 32.25 32.25 37.25 unr,,; ? ttli4i°J1'h ,a ip6 IP/ '9Y,I I;N43G N,I 32.25 32.25 43.25 Allied 4AC14B60P-6,7 Lennox Horz. XC13-018-230-04, -05 28 27 27 Lennox XC13-024-230-07,-08 XC13-030-230-03, 04 Lennox Lennox Horz. XC13-036-230-07, -08 28 27 31 Small Lennox XC14-018-230A." EL16XC1-018-230A PAGE 3 OF 6 LENNOX RESIDENTIAL UNITS - 2017 FLORIDA BUILDING CODE PREMIER STRUCTURAL ENGINEERING CA# 29113 THE FOLLOWING UNITS MAY BE USED AT NON -ROOFTOP INSTALLATIONS OF UP TO 10 FEET ABOVE GROUND WITHOUT PANEL MODIFCATIONS. Dimensions Product Line Base Size Brand Coil Protection Louver Design Model Number Length Width Height (inches) (Inches) (Inches) Lennox X1313-018-230-10, -11, -12 Lennox Horz. XP13-024-230-10, -11, -12 28 27 35 Lennox XP16-024-230-11 Lennox XC13-060-230-08, -10 Lennox XP13-030-230-09, -10 lennox XC14-024-230A** lennox Horz. XC16-036-230-05 35 30.5 31 Lennox XC16SO36-230-05 Lennox SSB036H4S45Y EL16XC1-024-230A Lennox SSB036H4S45G XC13-048-230-06, -08 Lennox Lennox Horz. XP13-048-230-09 35 30.5 35 Lennox XC14-042-230A** ED 6XC1-042-230A Elite Lennox Louver XP14-036-230-10 XC13-042-230-03, -04 Lennox Lennox XP13-036-230-09 Lennox XP13-060-230-09 Medium Lennox XC14-030-230A** EL16XCl-030-230A Lennox XC14-036-230A** EL16XCl-036-230A Lennox XC14SO36-230A** Lennox XC14-041-230-04 EL16XC1-041-230-04 Lennox Horz. XC14-048-230-08 EL1 6XC 1 -048-230-08 35 30.5 39 Lennox XP14-018-23OA10 Lennox XP14-024-230-09 Lennox XP14-030-230-09 Lennox XC16-048-230-04 Lennox XC16SO48-230-04 Lennox SSB048H4S44Y Lennox SSB048H4S44G XC16-024-230-04 lennox Lennox Horz. XC16SO24-230-04 35 30.5 45 Lennox I XP13-042-230-09 4SCU13LE118P-5* 4SCU13LE124P-5* Horz. 26.75 24.75 25.75 4SCU1318118P-3* 4SCUl31-6124P-3* 4SCU13LE13OP-5* 4SC U13LE136P-5* 4SCU1318130P-3* Small Allied Horz. 4SCU13LB136P-3* 26.75 24.75 29.75 4SC U14L6118P-7* 4SCU14LBR18P-7* 4SCU14LE118P-7* 4SCUl 6LS1 24P-1 4HP16LT24P Horz. 4SHP16LS124P 26.75 24.75 33.75 4SCU13LE142P-5* 4SCU13LE160P-5* 4SCU13LB142P-3* 4SCU1318160P-3* 4SCU1418124P-7* 4SCU14LBR24P-7* Horz. 4SCU14LE124P-7* 31.25 29.38 29.75 4SCU14LER124P-7* 4SCU14LE142P-4* 4SC U14LB142P-4* 4SCU14LBR142P-7* 4AC16LS136P-IA 4SCU1 3LE1 48P-5* 4SCU13LB148P-3* 4SCU1 4LE1 42P-7* 4SCU14LER142P-7* 4SCU14LB142P-7* Horz 4SCU14LBR142P-7* 31.25 29.38 33.75 4SCU14LB148P-4* 4SCU14LE148P-4* 4SHP1 4LB1 36-7 4SHP14LE136-7 4SCU14LE141P-4* Medium Allied 4SCU14LE147P-4* 4SCU14LB13OP-7* 4SCU14LBR13OP-7* 4SCU14LB136P-7* 4SCU14LBR136P-7* 4SCU14LE13OP-7* Allied Rounded 4SCU14LER136P-7* Square Louver 4SCU14LE136P-7* 4SCU14LER136P-7* Horz. 4SCU16LS148P-I* 31.25 29.38 37.75 4SHP1418118P-7 4SHP14LB124P-7 4SHP1418130P-7 4SHP14LE118P-7 4SHP1 4LE1 24P-7 PAGE 4 OF 6 LENNOX RESIDENTIAL UNITS .2017 FLORIDA BUILDING CODE PREMIER STRUCTURAL ENGINEERING CAX 291 i3 THE FOLLOWING UNITS MAY BE USED AT NON -ROOFTOP INSTALLATIONS OF UP TO 10 FEET ABOVE GROUND WITHOUT PANEL MODIFCATIONS. Product Line Base Size Brand Coil Protection Louver Design Model Number Dimensions Length Width Height (inches) I (Inches) (Inches) 4SHP1 4LE1 30P-7 4AC16LT48P 4SCU16LS148P 4HP16LT36P Horz. 4AC16LT60P 31.25 29.38 43.75 4SCU16LS160P-1" 4SCU14LB16OP-4' 4SCU14LE159P-4" 4SCU14LE16OP-4' 4SHP14LB142P-7 Horz. 4SHP1 4LB1 48P-7 37.75 35.75 37.75 4SHP14LE142P-7 4SHP14LE148P-7 4HP16LT48P 4SHP14116160P-7 4SHP14LE16OP-7 4HP16LT60P 4SHP16LS160P 4AC 18 LT24P Large Allied 4AC18LT36P 4AC18LT48P 4AC 18LT60P 4SCU18LT124P-1' Horz. 4SCU18LT13613-137.75 35.75 43.75 4SCU18LT148P-1' 4SCU18LT160P-1' 4HP18LT24P 4HP18LT36P 4HP18LT48P 4HP18LT60P 4SHP18LT124P 4SHP18LT136P 4SHP18LT148P 4SHP18LT160P PAGE 5 OF 6 ''.LENNOX RESIDENTIAL UNITS -2017 FLORIDA BUILDING CODE PREMIER STRUCTURAL ENGINEERING CA# 29113 THE FOLLOWING UNITS REQUIRE FIELD MODIFICATIONS (ADDITIONAL SCREWS) FOR NON -ROOFTOP INSTALLATIONS OF UP TO 10 FEET ABOVE GROUND. Dimensions Product Line Base Size Brand Coil Protection Louver Design Model Number Length Width Height (inches) (Inches) (Inches) Lennox XC14-047-230-04 EL16XC1-047-230-04 Lennox XC14-060-230-04, -05 Lennox XP16-036-230-09 EL16XC1-060-230-04 Lennox Horz. SPB036H4S48Y 39.5 35.5 35 Lennox XP16-048-230-08 Lennox SPB04BH4S48Y XP14-042-230-09 Lennox Lennox XP14-048-230-09 Lennox XC20-024-230A"" Lennox Horz XC20-036-230A** 39.5 35.5 39 Lennox XP20-024-230A"" Elite Large Lennox Louver XP20-036-230A** XC16-060-230-05 Lennox Lennox XC16SO60-230-05 Lennox SSB060H4S44Y Lennox SSB060H4S45G Lennox XP14-060-230-09 Lennox Horz. XP16-060-230-08 39.5 35.5 45 Lennox SPB060H4S48Y Lennox XC20-048-230A** Lennox XC20-060-230A** Lennox XP20-048-230A** Lennox XP20-060-230A** Lennox XP17-024-230-09 Lennox XP17-030-230-10 Lennox XP17-036-230-09 Lennox XP17-042-230-09 Lennox Horz XP21-024-230-07 39.5 35.5 37 Lennox XP21-036-230-06 Lennox XP25-024-230-01 Lennox XP25-036-230-01 Lennox SL18XP1-024-230A*" Lennox SL18XP1-030-230A*" XC17-024-230-08 Lennox Lennox SL18XC1-030-230A*" Lennox Horz. SL18XC1-036-230A** 39.5 35.5 41 Lennox SL18XC1-042-230A** Lennox SL18XP1-036-230A** Lennox SL18XP1-042-230A** XC17-030-230-08 Lennox Lennox XC17-036-230-08 Lennox XC17-042-230-08 Lennox XC17-048-230-08 Dave Lennox Lennox XC17-060-230-08 Large Louver Signature Series Lennox XP17-048-230-09 Lennox XP17-060-230-09 Lennox SL18XC1-024-230A** Lennox SL18XC1-048-23OA" Lennox SL18XC 1-060-230A* * Lennox SL18XP1-048-23OA** Lennox SL18XP1-060-230A** Lennox XC21-024-230-10 Horz 39.5 35.5 47 Lennox XC 21-036-230-10 Lennox XC 21-048-230-10 Lennox XC21-060-230-11 Lennox XP21-048-230-06 Lennox XP21-060-230-06 Lennox XC25-024-230-01 Lennox XC25-024-230-02 Lennox XC25-036-230-01 Lennox XC25-048-230-01 Lennox XC25-060-230-01 Lennox XC25-060-230-02 Lennox XP25-048-230-01 Lennox XP25-060-230-01 ALLIED 4SCU20LX AND 4SHP20LX MODELS ELITE SERIES LENNOX XCZ20 MODELS 37.5-43.11 37.75 35.75 PAGE 6 OF 6 LENA(N7,6DX INSTALLATION PROCEDURE 507575-01 August 21, 2015 Installation Kit for Securing Elite and Dave Lennox Signature Series Louvers for High Wind Events (14R10) Units that are exposed to wind shall be designed and installed to resist the wind pressures determined in accordance with the Florida Building Code. This kit consists of this instruction and four sheet metal screws. This kit is required for medium and large base Elite®and all Dave Lennox Signature®Collection outdoor units. REQUIRED TOOLS: Electric or cordless drill, drill bit capable of drilling into metal (.125" or 1/8"), 1/4" nut driver or drill socket. ELITES M 'c. 'B' DAVE LENNOX S/GNATURE®COLLECTION DIM "B" DIM "C" MEDIUMBASE 30.50 35.00 LARGE BASE 35.50 3 9. 40 DIM "B" DIM "C" ALL SAME SIZE 30.50 35.00 WARNING! BEHIND THE LOUVER PANELS IS THE OUTDOOR COIL WHICH CONTAINS R-410A HIGH PRESSURE REFRIGERANT. HAZARDS EXIST THAT COULD RESULT IN PERSONAL INJURY OR DEATH. TAKE EXTREME CARE WHEN DRILLING THE HOLES INTO THE LOUVERS OR BASE LIP TO PREVENT PUNCTURING THE REFRIGERANT COPPER PIPES. d .25 25 I 2.50 2.50 STEP A - DRILL IN THE LOCATIONS INDICATED. DRILL ONLY THROUGH THE LOUVER. DO NOT PENETRATE THE UNIT BASE LIP. THE BASE LIP WILL NEED TO BE DRILLED AFTER THE LOUVER IS REMOVED. REPEAT STEP FOR THE OPPOSITE SIDE LOUVER. STEP B - REMOVE LOUVERS AND DRILL THROUGH THE BASE LIP WHERE MARKED BY THE DRILL BIT WHEN DRILLING THROUGH THE LOUVERS IN STEP A. IMPORTANT - WHEN DRILLING THROUGH THE BASE LIP, PROTECT THE COIL FROM DAMAGE BY PLACING A SOLID OBJECT (PIECE OF METAL, BLOCK OF WOOD, ETC.) BETWEEN THE LIP AND THE COIL. PROVIDED SCREWS e� ra, SHEET METAL SCREW 100020-01 #8-18 x 3/4" WITH SPHERICAL POINT STEP C - REINSTALL LOUVERS AND SECURE TO THE BASE USING THE PROVIDED SCREWS AND THE HOLES PREVIOUSLY DRILLED. Y P.O: BOX 948067, MAITLAND, FL 32794 ph: 407-227-7416 web: www.premier—structural.com PREMIER Certificate of Authorization# 29113 ATwUCnRAISED seal below authenticates original copies. Photo copies are not acceptable. LENNOX RESIDENTIAL UNITS TIE -DOWN REQUIREMENTS 4" MIN TYP. LENNOX RESIDENTIAL UNITS TIE DOWN INSTALLATIONS AT GRADE SHEET NO.: 1 OF 2 CALCULATED BY: KAR DATE: 05/01/2020 CHECKED BY: KAR DATE: 05/01/2020 SCALE: NTS DETAIL NOTES: 1. ALL DIMENSIONS AND THE MINIMUM WEIGHT(100 LB MIN.) OF MECHANICAL UNIT SHALL CONFORM TO LIMITATIONS STATED HEREIN. MECHANICAL UNIT SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE PER THE MANUFACTURER'S RECOMMENDATIONS AND ARE THE RESPONSIBILITY OF THE CONTRACTOR. Z 2. TAPCONS REFERRED TO HERON SHALL BE ITW BUILDEX BRAND, ASTM F593 410 STAINLESS STEEL ONLY OR EQUIVALENT. SEE ANCHOR SCHEDULE FOR ANCHOR SIZE AND EMBEDMENT REQUIREMENTS ALL SHEET METAL SCREWS USED TO FASTEN BRACKETS TO MECHANICAL UNITS SHALL BE #10 (14 MIN THREADS PER INCH) ASTM F593 410 STAINLESS STEEL ONLY OR EQUIVALENT. PROVIDE (5) PITCHES MINIMUM PAST THE THREAD PLANE FOR SHEET METAL SCREWS. ALL FASTENERS SHALL HAVE APPROPRIATE CORROSION PROTECTION TO PREVENT ELECTROLYSIS. 40" MAX (4) TIE DOWN BRACKETS 14 GA. MIAMI TECH CLIP OR EQUIVALENT REF. MERIT, AIRE—FLO AND ALLIED SERIES UNITS — PLAN VIEW SHEET 2. 3" (4) TIE DOWN BRACKETS MIN 14 GA. MIAMI TECH CLIP OR EQUIVALENT REF. SHEET 2. � TYP• 40" MAX ELITE AND DAVE LENNOX SIGNATURE SERIES UNITS — PLAN VIEW 3. CONCRETE SUBSTRATES SHALL BE AT A MINIMUM 4' THICK AND WITH A MINIMUM COMPRESSIVE STRENTH OF 3000 PSI. 4. CONTRACTOR MALL INSULATE ALL MEMBERS AND ATTACHMENTS FROM DISSIMILAR MATERIALS IN ORDER TO PREVENT ELECTROLYSIS. 5. ELECTRICAL GROUND (AS REQUIRED) SHALL BE DESIGNED BY OTHERS. 6. ADEQUACY OF THE EXISTING BUILDING STRUCTURE TO WITHSTAND SUPERIMPOSED LOADS SHALL BE DETERMINED BY OTHERS 7. WATER —TIGHTNESS OF EXISTING SUBSTRATE SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER INSTALLATION OF MECHANICAL UNITS PREMIER STRUCTURAL ENGINEERING INC. SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR SINCE WATER —TIGHTNESS IS BE THE FULL RESPONSIBIUTY OF THE INSTALLING CONTRACTOR. DESIGN CRITERIA: 2017 FLORIDA BUILDING CODE — ULTIMATE DESIGN WIND SPEED = 186MPH — RISK CATEGORIES = III AND IV WIND EXPOSURES = D — MEAN ROOF HEIGHT UP TO 60 FEET P.Ot BOX 948067, MAITLAND, FL 32794 ph: 407-227-7416 web: www.premier—structural.com Certificate of Authorization# 29113 RAISED seal below authenticates original copies. LENNOX RESIDENTIAL UNITS JOB: TIE DOWN INSTALLATIONS AT GRADE SHEET NO.: 2 OF 2 CALCULATED BY: KAR DATE: 05/01/2020 CHECKED BY: KAR DATE: 05/01/2020 DESIGN CRITERIA: 2017 FLORIDA BUILDING CODE - ULTIMATE DESIGN WIND SPEED = 186MPH RISK CATEGORIES = III AND IV - WIND EXPOSURES = D MEAN ROOF HEIGHT UP TO 60 FEET #10-14 S.S. ------ U 3/4" LONG SCREWS O W/ NEOPRENE WASHERS (3 PER CLIP). ATTACH CLIPS O TO NON -LOUVER PORTION OF O UNIT SIDE PANELS. SEE SHEET 1 FOR CLIP QUANTITY AND O APPROX. LOCATIONS. 8" LONG x. O 1" WIDE x 14 GA .ANCHOR CLIP STAINLESS STEEL OR GALV. O m O ANCHOR TO SUBSTRATE SEE SCHEDULE (BELOW) ANCHOR SCHEDULE CONCRETE: (1) - 1/4" DIA. 410 STAINLESS 4" MINIMUM THICKNESS STEEL TAPCON OR EQUIVALENT. MIN. 3000 PSI 1 3 4" EMBED - 3" MIN EDGE DIST. - 4" MIN SPACING STEEL: MIN. THICKNESS = 0.125" (1) - 1/4" DIA. STAINLESS MIN. YIELD STRENGTH = 33 KSI STEEL THRU BOLT W/ S.S. WASHERS AND NUT.