Loading...
EL-12-20-2867, 1181 NE 92nd StMiami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Parcel Number 1181 NE 92ND ST, Miami Shores, FL 33138 1132050270340 Contacts ANDREW BEYDA Owner CARIBE ELECTRICAL CONTRACTOR INC Contractor 1181 NE 92ND ST, Miami Shores, FL 33138 ELIGIO FIGUEROA abeyda@gmail.com 261 W 27 ST, HIALEAH, FL 33010 Business: 7864120067 Description: NEW POOL Valuation: $ 1,500.00 Inspection Requests: Total Sq Feet: 450.00 y ' Fees Amount Application Fee - Other $50.00 CCF $1.20 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.40 Permit Fee $50.00 Scanning Fee $3.00 Technology Fee $2.50 Total: $111.10 Building Department Copy Payments Date Paid Amt Paid Total Fees $111.10 Credit Card 09/09/2021 $111.10 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction an_,zoning. Futhermore, I authorize the above named contractor to do the work stated. g�C-t(L� Authorized Signalrure: Owner / Applicant / Contractor / Agent Date September 09, 2021 Page 2 of 2 Miami Shores Village rl; _,.' - " ""o Building Department BY: 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ( () FBC 20 ff �J( BUILDING Master Permit No.6 12z028L07 PERMIT APPLICATION Sub Permit No. -r'L 12r2�' zzel ❑BUILDING ❑■ ELECTRIC ❑ ROOFING REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOBADDRESS: 1181 NE 92 St City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Andrew Beyda Phone#: 786-897-5803 Address: 1181 NE 92 St City: Miami Shores State: FL Zip: 33138 Tenant/Lessee Name: Email one#: CONTRACTOR: Company Name: V��` �'/ %7 �'�� l�O SIT- Phone#: ! ✓ so"2 !' -; . Address:���/ City: TTj/ ;-,1 X—Y State: 12!1 Zip: 3 .3 O/ D Qualifier Name:/r �iUy- / 7��-� Phone#: State Certification or Registration #:C l3 w5g % Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 1500.00 Square/Linear Footage of Work: 450 sq ft Type of Work: ❑ Addition ❑ Alteration 0 New ❑ Repair/Replace ❑ Demolition Description of Work: New Pool t Specify color of color thru tile: Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ _ CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ (Revised02/24/2014) TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature �- OWNER or AGENT The foregoing instrument was acknowledged before me this /jL� day of �(/ ►�-�,I� 20 d by / OW,t,) , wh Cis no o me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign:_ Print: Signature I Q� CONTRACTOR The foregoing instrument was acknowledged before me this day of 1 /-�Ci in %"` 20 �0 by who s pe=known me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Print: y u ic- rate t Florida `\ qY P I ,P oa tuchrst,n wvuniuutc Seal: =N 'S Commission # HH 34889 '.; My Commission Expires W. Seal: , °, ,m�, ,,,' �e" Notary Public -State of Florida Commission # HH 34889 °°.� ' �' ° October 19. 2024 ;'�"fYYi®i �"P�' '''�°ii My Commission Expires �`'� October 19, 2024 APPROVED BY 7OLPlans Examiner Zoning Structural Review Clerk (Revised02/24/2014) protection. (6) Provide geotechnical investigation and recommendations report for the swimming pool. section 1803 of 2017 FBC. Geo report not provided. Corrective Action: Pending the following comments. (1) Plumbing approval required. (2) Provide copy of original signed contract between owner and contractor and sub -contractors. In addition provide cost of all fixtures and materials to be provided by the property owner. The cost provided on the contract does not reflect the market cost of similar projects within our area and there by additional information is required. Provide detail itemized cost estimate for the project to include all materials, labor overhead and profit, in addition provide the cost of all materials to be provided by the property owner. Florida Building Code section 109.3 (5) Pool equipment should be elevated to meet flood elevation. Provide equipment pad elevation in NGVD. In addition, please correct pool equipment locations on all plans. According to the flood map the subject property is in a AE-9 flood zone. The minimum elevation required per miami Shores Village code of ordinances is 11.00 NGVD, however, section 1612.4.2 allows the equipment to be below as long as it is elevated to the extent practical, is anchored to prevent flotation and resist flood forces, and is supplied by branch circuits that have ground fault circuit -interrupter protection. In addition the equipment location has not been properly reflected on all applicable sheets. Section 9.6 in ASCE 24 by adding an exception as follows: 9.6 Pools 1612.4.2 Modification of ASCE 24 9.6 Pools. Modify Section 9.6 in ASCE 24 by adding an exception as follows: 9.6 Pools Exception: Equipment for pools, spas and water features shall be permitted below the elevation required in Table 7-1, provided it is elevated to the extent practical, is anchored to prevent flotation and resist flood forces, and is supplied by branch circuits that have ground fault circuit -interrupter protection. here Building v.4 In Review Ismael Naranjo email: bo@msvfl.gov Correction: General - Ismael Naranjo (7/27/21) - Not Resolved Electrical v.1 Approved Michael DeVaney email: el@msvfl.gov Comments: ALSO EL 12-20-2867 Planning v.1 Requires Re -submit Travis Kendall email: kendallt@msvfl.gov Comments: Mechanical must be a minimum of 10 feet from the property line. Planning v.2 Approved Travis Kendall email: kendallt@msvfl.gov Plumbing v.1 Comments: FBC 107.1 Provided filter size Plumbing v.2 Comments: FBC 107.1 Provided filter size Plumbing v.3 Requires Re -submit Maykel Massanet email: plumbing@msvfl.gov Requires Re -submit Maykel Massanet email: plumbing@msvfl.gov Requires Re -submit Maykel Massanet email: plumbing@msvfl.gov Correction: General - Maykel Massanet (6/2/21) - Not Resolved Corrective Action: FBC 107.1 Health Department approval required provided pool filter detail Plumbing v.4 In Review Miguel Cabrera email: PL@msvfl.gov Correction: General - Maykel Massanet (7/27/21) - Not Resolved Structural v.1 Requires Re -submit Orlando Blanco email: bz3@msvfl.gov Correction: General - Orlando Blanco (2/2/21) - Not Resolved Comments: REFER TO THE ATTACHED COMMENTS Corrective Action: 1. SITE SPECIFIC GEOTECHNICAL REPORT, SIGNED AND SEALED BY FLORIDA ENGINEER, IS REQUIRED FOR THE DES SPECIFICATIONS FOR ALL PILE FOUNDATIONS IN COMPLIANCE WITH SECTION 1810, PROVISIONS OF THE FBC 6th EDITION (2017) CO 2. PROVIDE TWO COPIES OF SPECIAL INSPECTOR FORM, FULLY EXECUTED FOR : A) MIAMI DADE COUNTY ADMINISTRATIVE CODE, ARTICLE II, SECTION 8-22 ❑ PILE FOUNDATIONS July 29, 2021 10050 NE 2 Ave Miami Shores FL 33138 Page 2 of 3 RECFlvpn BY:_� Client: Andrew Beyda 1181 NE 92 St Miami Shores, FL 33138 Pool Construction Breakdown Excavation and backfill with Land Rock: $1,900.00 Pool shell framing: $2,700.00 Rebar 3250 If: $1,625.00 Gunite 25 yards of concrete: $4,875.00 Pool coping and deck 300 sq. ft.: $5,100.00 Pool waterline and step tile: $2,240.00 Pool plumbing including equipment: $8,000.00 Pool electrical: $2,200.00 Pool coating: $3,200.00 Total: $31, 840.00 Alex Rodriguez President COMMERCIAL• RESIDENTIAL• INDUSTRIAL 4474 Weston Road. PMB 107.Davie, FL 33331.Ph.305.710.7861 Email.Info@crrgc.com