Loading...
REV-05-22-1165, 162 NW 108th StMiami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Parcel Number 162 NW 108TH ST, Miami Shores, FL 33168 1121360100060 z Contacts .......m.......... _._............... _._... Jovens Degage Owner ANOTHER CREATION HOME INC Contractor 162 NW 108 ST, Miami Shores, 33168 NATHANIEL CURRY Mobile: 3058499102 JOVENS.DEGAGE@YAHOO.COM 1535 NW 180 TER, MIAMI, FL 33169 Business:6782494730 NATECURRY@ANOTHERCREATIONHOM ES.COM Inspection Requests: Description: NO AC DUCK, MINI SPLIT AC � Valuation: $ 0.00 305-762-4949 Total Sq Feet: 0.00 Fees Amount Revision: Minor Change of Plans $40.00 Revision: Minor Change of Plans $40.00 Scanning Fee (Manual) $9.00 Tota I : $89.00 Building Department Copy Payments Date Paid Amt Paid Total Fees $89.00 Credit Card 06/13/2022 $89.00 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulatiuction and zoning. Futhermoorre, I authorize the above named contractor to do the work state Signature: Owner / `JApplicant / Contractory / Agent Date June 13, 2022 Page 2 of 2 Miami Shores Village P---EcElvF�L) Building Department YjA)' 06 �'022 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY: Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 BUILDING Master Permit No. Rc-o9.-10 -' G� PERMIT APPLICATION Sub Permit No. —� m— � � BUILDING ❑�Vzz-��tvS ELECTRIC ROOFING 'REVISION ❑ EXTENSION RENEWAL ❑ PLUMBING ❑ MECHANICAL ❑ PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: I c'-�_ rVW I o% _� T City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Tvpe: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): �30VCVV_5 VC 'n.Gf_ Phone#: Address: rVW 107 5 T U v City: AA � G 114 t S k_G r"C:S State: Zip: Tenant/Lessee Name: Email: Phone#: CONTRACTOR: Company Name: l' no l eK— (A—recJ't,cwk 4omes fin. C Phone#: (�),59 `'�X,_co Address: 2�_O 3 .SW At City: _Dovya -,- �j State: FL- Zip: 33.3 n� Qualifier Name: "Ck 1 V1Ci411l t { I CVf t V ff- Phone#: &7Z) ca 4 cl"q'% 30 State Certification or Registration #: CG-C, l 51gl 317 C'k Certificate of Competency #: DESIGNER: Architect/Engineer: Address City: Phone#: State: Zip: Value of Work for this Permit: $ 0 Square/Linear Footage of Work: Type of Work: ❑ Addition /❑ Alteration /�❑ New ❑ Repair/Replace ❑ Demolition Description of Work: h1 V h C,� J U C r_ (:� , M I wI S�k) I+ Specify color of color thru tile: Submittal Fee $ Scanning Fee $ Technology Fee $ Structural Reviews $ (Revised02/24/2014) Permit Fee $ Radon Fee $ Training/Education Fee $ CCF $ CO/CC $ - DBPR $ Notary $. Double Fee $ _ Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this C� f-k day of MC.y-` 20 k'_)" , by leveut5 DecGc-,C E. who is1-i Ili personally kno�ernto me or who has produced NaA/ as identification and who did take an oath. NOTARY PUBLIC: Signature CONTRACTOR The foregoing instrument was acknowledged before me this day of MGiv 20 by NTVtan�E �t,,rr u who is personally known to me or who has produced /VCAN6 as identification and who did take an oath. NOTARY PUBLIC: Sign: %L��1 —�/ Sign: Print: �tnf x l VI.0M cn 5 Print: Rll&f� 711 GbY c s Seal: f,i", RUTH THOMAS I Seal: `6 Z� Notary Public State of Florida roi Y P"Ir11 RUTH THOMAS Commission t HH 198439 Y Notary Public •State of Florida My Comm. Expires Nov 14, 2025 a' Commission # HH 198439 rid h u N ti OF �a�,��` *M tSonaed through National Notary Assn, APPROVED BY Plans Examiner Zoning (Revised02/24/2014) Structural Review Clerk Emerson Quiet Kool 20 SEER 12,000 BTU 1 Ton r . Duchess Mini -Split Air Conditioner with inverter, 40 Heat, Remote and Wi-Fi 115V/60 Hz Wj OVERVIE SPECIFICATIONS REVIEWS Model: 19S-EACH12R1 W Internet/Catalog: 314024982 Store SKU: 1005582561 Keep your home cool and comfortable with Emerson Quiet Kool's 12,000 BTU 115V Ductless Split Conditioner. Controlling your rooms temperature is easy with the included wireless remote or the Alexa and Google Assistant enabled smart app. With premium features like super -fast heating and cooling, sleep mode and a swing that adjusts louvers, this air conditioner delivers superior performance. The compact ... View More Q WARNING Warning: Cancer and Reproductive Harm - www. P Warnin s.ca. c v Shipping Details Ships FREE Emerson Quiet Kooi 20 SEER 12,000 BTU 1 Ton Ductless Mini -Split Air Conditioner with Inverter, Heat, Remote and Wi-Fi 115V/60 Hz SPECIFICATIONS Model: 19S-EACH12R1 W Internet/Catalog: 314024982 Store SKU: 1005582561 REVIEWS Keep your home cool and comfortable with Emerson Quiet Kool's 12,000 BTU 115V Ductless Split Conditioner. Controlling your room's temperature is easy with the included wireless remote or the Alexa and Google Assistant enabled smart app. With premium features like super -fast heating and cooling, sleep mode and a swing that adjusts louvers, this air conditioner delivers superior performance. The compact ... View More Q WARNING Warning: Cancer and Reproductive Harm - www. P65Warnings.ca.cgov Shipping Details Ships FREE 0 " WrlghtSOft® Building Analysis Date: June24,2019 Entire House By: Arcon Engineering Group, Inc. 1175 N.E. 125 St. Suite. 209, North Miami, FL 33161 Phone: (305) 899-9465 Fax: (305) 899-9580 Email: arconengineering@comcast.net Web: none For: JOVENS DEGAGE JOVEN DEGAGE 162 NW 108 STREET, Miami, FL 33168 Phone: 305 849-9102 Location: Indoor: Heating Cooling Miami, FL, US Indoor temperature (°F) 77 77 Elevation: 7 ft Design TD (°F) 27 13 Latitude: 26°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 25.8 52.3 Dry bulb (°F) 51 90 Infiltration: Daily range�0F) - 12 ( L ) Method Simplified Wet bulb (° ) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 6.8 2286 20.6 Glazing 21.1 1388 12.5 Doors 9.5 191 1.7 Ceilings 0.8 289 2.6 Floors 13.3 4982 45.0 Infiltration , 3.0 1260 11.4 Ducts 674 6.1 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 11069 100.0 Cooling Component Btuh/ft2 Btuh % of load Walls 5.1 1708 27.4 Glazing 18.5 1218 19.5 Doors 10.4 208 3.3 Ceilings 0.7 266 4.3 Floors 0 0 0 Infiltration 0.8 332 5.3 Ducts 918 14.7 Ventilation 0 0 Internal gains 1590 25.5 Blower 0 0 Adjustments 0 Total 1 1 6240 100.0 Latent Cooling Load = 1619 Btuh Overall U-value = 0.455 Btuh/ft2-°F Data entries checked. -+r- wrightsoft° Right -Suite® Universal 2015 15.0.22 RSU09986 ACC11CADEGARE ROOM UNIT.rup Calc = MJ8 Front Door faces: N ains 2022-Apr-19 19:31:40 Page 1 Load Short Form Job: -- wrightsoft® Date: June 24,2019 Entire House By: Arcon Engineering Group, Inc. 1175 N.E. 125 St. Suite. 209, North Miami, FL 33161 Phone: (305) 899-9465 Fax: (305) 899-9580 Email: arconengineering@comcast.net Web: none For: JOVENS DEGAGE, JOVEN DEGAGE 162 NW 108 STREET, Miami, FL 33168 Phone: 305 849-9102 Htg Clg Infiltration Outside db (°F) 51 90 Method Simplified Inside db (°F) 77 77 Construction quality Average Design TD (°F) 27 13 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 26 52 HEATING EQUIPMENT Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat n/a 0 Btuh 0 Btuh 0 °F 0 cfm 0 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make BRYANT Trade BRYANT Cond CA16NA042-B Coil AHRI ref Efficiency 11.3 EER, 11.3 SEER Sensible cooling 8400 Btuh Latent cooling 3600 Btuh Total cooling 12000 Btuh Actual air flow 325 cfm Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.79 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) NEW BEDROOM 280 8620 5044 0 263 BATHROOM 96 2450 1196 0 62 Entire House 376 11069 6240 0 325 Other equip loads 0 0 Equip. @ 0.95 RSM 5953 Latent cooling 1619 lr^TA 1 C• 9�P_ 4 A nnn �E�n A in Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl htSOft 2022-Apr-1919:31:40 g Right -Suite® Universal 2015 15.0.22 RSU09986 Page 1 ACCA CADEGARE ROOM UNIT.rup Calc = MJ8 Front Door faces: N Pro rJob: ect Summay, wrightsoft® � ' �7 date: June 24,2019 Entire House By: Arcon Engineering Group, Inc. 1175 N.E. 125 St. Suite. 209, North Miami, Fl- 33161 Phone: (305) 899-9465 Fax: (305) 899-9580 Email: arconengineering@comcast.net Web: none For: JOVENS DEGAGE, JOVEN DEGAGE 162 NW 108 STREET, Miami, FL 33168 Phone: 305 849-9102 Notes: Weather: Miami, FL, US Winter Design Conditions Outside db 51 OF Inside db 77 OF Design TD 27 OF Heating Summary Structure 10395 Btuh Ducts 674 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 11069 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ft2) 376 376 Volume (ft3) 3760 3760 Air changes/hour 0.69 0.36 Equiv. AVF (cfm) 43 23 Heating Equipment Summary Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency n/a Heating input 0 Btuh Heating output 0 Btuh Temperature rise 0 OF Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Space thermostat Summer Design Conditions Outside db 90 OF Inside db 77 OF Design TD 13 OF Daily range Relative humidity L 50 % Moisture difference 52 gr/lb Sensible Cooling Equipment Load Sizing Structure 5322 Btuh Ducts 918 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 5953 Btuh Latent Cooling Equipment Load Sizing Structure 1402 Btuh Ducts 217 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 1619 Btuh Equipment total load 7572 Btuh Req. total capacity at 0.70 SHR 0.7 ton Cooling Equipment Summary Make BRYANT Trade BRYANT Cond CA16NA042-B Coil AHRI ref Efficiency 11.3 EER, 11.3 SEER Sensible cooling 8400 Btuh Latent cooling 3600 Btuh Total cooling 12000 Btuh Actual air flow 325 cfm Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Apr-19 19:31:40 wrightsoft® Right -Suite® Universal 2015 15.0.22 RSU09986 Page 1 ACC& CADEGARE ROOM UNIT.rup Calc = MA Front Door faces: N 9 ® AED Assessment Job: Wil htSOft Date: June 24,2019 Entire House By: Arcon Engineering Group, Inc. 1175 N.E. 125 St. Suite. 209, North Miami, FL 33161 Phone: (305) 899-9465 Fax: (305) 899-9580 Email: arconengineering@comcast.net Web: none For: Location: Miami, FL, US Elevation: 7 ft Latitude: 260N Outdoor: Dry bulb (°F) Daily range (°F) Wet bulb (°F) Wind speed (mph) JOVENS DEGAGE, JOVEN DEGAGE 162 NW 108 STREET, Miami, FL 33168 Phone: 305 849-9102 Indoor: Heating Cooling Indoor temperature (°F) 77 77 Design TD (°F) 27 13 Relative humidity (%) 50 50 Heating Cooling Moisture difference (gr/lb) 25.8 52.3 51 90 Infiltration: - 12 (L ) - 77 15.0 7.5 Hourly Glazing Load 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hourly �w' Average / AED limit Maximum hourly glazing load exceeds average by 16.0%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh � 2022-Apr-1919:31:40 A WCI htsoftRight-Suite® Universal 2015 15.0.22 RSU09986 Page 1 C:\DEGARE ROOM UNIT.rup Calc = MJ8 Front Door faces: N -r- wrightsoft°' Right-J® Job: Date: Entire House Date: June 24,2019 BY: Arcon Engineering Group, Inc. 1175 N.E. 125 St. Suite. 209, North Miami, FL 33161 Phone: (305) 899-9465 Fax: (305) 899-9580 Email: arconengineering@comcast.net Web: none 1 Room name Entire House NEW BEDROOM 2 Exposed wall 58.0 ft 34.0 ft 3 Room height 10.0 ft 10.0 ft heat/cool 4 Room dimensions 20.0 x 14.0 ft 5 Room area 376.0 ft' 280.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ft? °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W. 13AB-0ocs 10B-b 0.258 0.750 n n 6.84 19.88 5.11 13.93 420 40 334 0 2286 795 1708 557 340 40 281 0 1923 795 1437 557 1 D-c2om 0.870 n 23.06 25.70 26 0 593 661 19 0 431 481 D 11 KO 0.360 n 9.54 10.40 20 20 191 208 0 0 0 0 C 11 17A-31ad 0.029 0.77 0.71 376 376 289 266 280 280 215 198 F Bg floor, light dry 1.000 13.25 0.00 376 376 4982 0 280 280 3710 0 6 c) AED excursion 0 0 Envelope loss/gain 9135 3400 7075 2673 12 a) Infiltration 1260 332 1020 269 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 11360 1 1 1130 Subtotal (lines 6 to 13) 10395 5322 8095 4302 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 10395 5322 8095 4302 15 Duct loads 6% 17% 6741 918 6% 17% 525 742 Total room load 11069 6240 8620 5044 Air required (cfm) 0 325 101 263 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft®. 2022-Apr-1919:31:40 9 Right -Suite® Universal 2015 15.0.22 RSU09986 Page 1 C:\DEGARE ROOM UNIT.rup Calc = MJ8 Front Door faces: N -rF wrightsoft, Right-J® Worksheet Job: Entire House Date: June 24,2019 By: Arcon Engineering Group, Inc. 1175 N.E. 125 St. Suite. 209, North Miami, FL 33161 Phone: (305) 899-9465 Fax: (305) 899-9580 Email: arconengineering@comcast.net Web: none 1 Room name BATHROOM 2 Exposed wall 24.0 ft 3 Room height 10.0 ft heat/cool 4 Room dimensions 8.0 x 12.0 ft 5 Room area 96.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13AB-0ocs 1OB-b 0,258 0.750 n n 6.84 19.88 5.11 13.93 80 0 53 0 362 0 271 0 1 D-c2om 0.870 n 23.06 25.70 7 0 161 180 D 11 KO 0.360 n 9.54 10.40 20 20 191 208 C 11 17A-31 ad 0.029 0.77 0.71 96 96 74 68 F Bg Floor, light dry 1.000 13.25 0.00 96 96 1272 0 6 c) AED excursion 0 Envelope loss/gain 2060 727 12 a) Infiltration 240 63 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 230 Subtotal (lines 6 to 13) 2300 1020 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2300 1020 15 Duct loads 6% 17% 149 176 Total room load 2450 1196 Air required (cfm) 0 62 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2022-Apr-19 19:31:40 Right -Suite® Universal 2015 15.0.22 RSU09986 Page 2 C:\DEGARE ROOM UNIT.rup Calc = MJ8 Front Door faces: N