RC-07-20-1621, 1065 NE 97Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
BUILDING Master Permit No.✓
PERMIT APPLICATION Sub Permit No.
ZBUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
PLUMBING M MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR
DRAWINGS
ICI S Al 6
7
JOB ADDRESS:
City: Miami Shores
County: Miami Dade
Zip: _3' 1..T
Folio/Parcel#:1;.E'S�
Is the Building Historically Designated: Yes NO
Occupancy Type: Load:
Type: Flood Zone:
BFE: _ FIFE:OWNER:
Construction
/
Name (Fee Simple Titleholder):
e
/ j t ' .L c; c" t
Phone#: 'TG> S - 3 L
Address: / C �' S� l �. _ c' %
S T
r
City: )11 "�� � 4 y r S
State:_
it
Zip: 3
Tenant/Lessee Name:
Phone#:
Y /
Email: r- vt e? t.'
��3��
i
f
CONTRACTOR: Company Name _ ti
lG��L—�--
Phone#: ?e, ';'• i_S-,' q
Address:
City: State: Zip:
Qualifier Name: Itiv-%. 6�-�rr'.t
.--- Phone#:
State Certification or Registration #: Z e, % Z G / S / `l Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address:
City:
Value of Work for this Permit: $ GG , 'c: Square/Unear Footage of Work:
Type of Work: ❑ Addition P AlteratEon ❑ New ❑ Repair/Replace
Description of Work:
Specify color of color thru tile:,
Submittal Fee $
Scanning Fee $
Technology Fee $
Structural Reviews $
Permit Fee $ CCF $_
Radon Fee $ DBPR $
Training/Education Fee $
Zip:
❑ Demolition
CO/CC $
Notary $
Double Fee $ _
Bond $
TOTAL FEE NOW DUE $
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..._.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction Gen law brochure will be delivered to the person
whose property is subject to attachment, Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occu s en (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved a oAi spection fee will be charged.
OWNER or
Signature
� _ CONTRACTQR _
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
_� _ day of IL 20 �, by _ � day of }Li� ' 20 p,Z , by
l GC'' eU 1 Cam_, who is personally known to �(txy) CC&J, ni�S , who is personally known to
me or who has produced j�[ t� S it per_ as me or who has produced as
2.00— 403- j
identification and who did take an oath.-� identification and who did take an oath.
NOT,
Sign
Print
Sea]:
NOTARY RUOLIC:
Print:
Seal:
*::�+rs:err+*:.��*.�.ssxss:.*sue *«•. .�.s*s***s*****s**s*�
APPROVED BY (DO Plans Exami e0i
STRUCTURAL REVIEW --1
APPROVED O. BLANCO
I 081041,020 1 . j: AM Structural Review
(Revised02/24/2014)
MY COMMISSION # GG08783.3
EXPIRES March 28. 2021
kp
. Zoning
Clerk
Date: August 3 Id 2020
State of Florida
Miami Shores County
Before this day personally appeared Juan Orriols who, being duty sworn, deposes and says:
That he will be the only person working on the project located at:
1065 NE 97' ST Miami Shores, Florida 33138
Contractor Signature
Sworn to (or affirmed) and subscribed before me this—Y' day of August 2020,
By 73Q)0'� U'Ti, OL
Personally Know (AV\
Or Produce Identification%,
Type of Identification Produced_
Notary Pubtic Stale
X of R
Print, Type or Stamp N me of Notary
7715 NW 56th ST Miami FL 33166
Ph:9542540491
Miami shores Village
Building Department
10050 N.E.2nd AIIII
venue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax, (305) 756.8972
Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05
allows corporate officers in the construction industry to exempt themselves from this requirement for any construction Project prior to
obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure:
An employer in the construction industry who employs one or more part-time or full-time
employees, including the owner, must obtain workers' compensation coverage, Corporate officers
or members of a limited liability company (1,LC) in the construction industry may elect to be
exempt if:
I , The officer owns at least 10 percent of the stock of the corporation, or in the case of
an LLC, a statement attesting to the minimum 10 percent ownership;
2. The officer is listed as an officer of the corporation in the records of the Florida
Department of State, Division of Corporations; and
3. The corporation is registered and listed as active with the Florida Department of
State, Division of Corporations.
No more than three corporate officers pet corporation or limited liability company members, are
allowed to be exempt. Construction exemptions are valid for a period of two years or until a
voluntary revocation is filed or the exemption is revoked by the Division.
`your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use
day labor, part-time employees or subcontractors for your project. The contractor has provided an affidavit stating that he or she will
be the only person allowed to work on your project. In these circumstances, Miami Shores Village does not require verification of
workers' compensation insurance coverage from the contractor's company for day labor, part-time employees or subcontractors.
BY SIGNING BELOW YOU ACKNOWLEDGED T THAT, YOU HAVE READ NOTICE AND UNDERSTAND ITS
COINTENTS.
Signature:,
t7tvner
State of Florida
County of Miami -Dade
The foregoing was acknowledge before me, this dfy of n
By 3):kV1 bvo4igpersonally known tome orbas produced
tomb
Notary: . ..... ...
MY GG 251778
SE',AL: Ex t3tSf22,20;,2
as identification.
_ ONLINE
BUILDING PLANS
ONLINE BUILDING PLANS CORP
FLORIDA OFFICE
..E tisF NUMSPEI�, A, a; E3924
PUERTO RICO OFFICE
PP'' c=:raed 92
;:lorida' e s.= 97.
53 .F.St. i-e2-
BUILDING REVIEW
APPROVED 1. NARANJO
08/24/2020 2:55:19 PM
Thursday, July 23, 2020
Regarding: Signature Authenticity & Digital Signature Verification
Project: xP20-0084
Address: 1065 NE 97 street, Miami, FL
As required by the Florida Statutes Chapter 481 and Florida Administrative Rule 61G1-16.005 for
Architects, i Victor R Vega Sanabria with license number AR 97719 attest that I have the following:
1. Florida statutes and administrative rules outline acceptable methods for design professionals to
digitally sign and seal plans and documents,
2. 1 complied with rule 61G1-16.005 "Procedures for Digitally Signing and Sealing and for
Electronically Transmitting Plans, Specifications, Reports or Other Documents"
3. My digital signature was issue by a 3,d Party Certification Authority that is accompanied by a
digitally created image of your seal and required language.
4. This item has been electronically signed and sealed on the Date and/or Time Stamp shown
using a digital signature.
This letter constitutes a signed and sealed statement attesting to the veracity of the method and software
used to sign and seal the plans and document
Be advised that printed copies of this document are not considered signed and sealed and the signature
must be verified on any electronic copies.
Project
P20-0084
Address
1065 NE 97 street, Miami.. FL
Content
Digital sign documents
NUMBER PDF FILE
TITLE
AO-0
P20-0084 SD - Sheet - AO-0 - TITTLE SHEET
A-100
P20-0084_So - Sheet - A-100 - Demolition and Proposed Floor Plan
A-200
P20-0084_So - Sheet - A-200 - Demolition and Proposed Elevations
A-603
P20-0084_So - Sheet - A-603 - Door & Windows
E-102
P20-0084 SD - Sheet - E-102 - Electrical first floor
Respectfully,
<Eov Ft pq
Digitally signed by Victor R Vega
q Pwec^s9 ��
Sanabria
o
DN: c=US, o=VRVS-ARQ-FL,
•
ou=A01410D0000016BD2B7EAE4
97719 7 '
'�
00002614, cn=Victor R Vega
Sanabria
rERED AR��
Date: 2020.07.2314:21:09-04'00'
Victor R. Vega Sanabria, AIA
ONLINE BUILDING PLANS CORP
ONLINE
BUILDING PLANS
ONLINE BUILDING PLANS CORP
FLORIDA OFFICE
LICENSE NUMBER. AA26003924
755{i W 2nd CT Hialeah
Florida 33014
�o c on e o" 1, i s conk
PUERTO RICO OFFICE
DR License #1 `922
Fianda License AR#977t9
154 ?aft St. Suite 201
Wednesday, September 2, 2020
Regarding. Signature Authenticity & Digital Signature Verification
Project: aP20-0084 Windows and door repiacernent
Address: '065 NE 1� ee'<" am� FL.
As required by the Florida Statutes Chapter 481 and Florida Administrative Rule 61G1-16.005 for
Architects. I Victor R Vega Sanabria with license number AR 97719 attest that I have the following:
1. Florida statutes and administrative rules outline acceptable methods for design professionals to
digitally sign and seal plans and documents.
2. 1 complied with rule 61G1-16.005 "Procedures for Digitally Signing and Sealing and for
Electronically Transmitting Plans, Specifications, Reports or Other Documents"
3. My digital signature was issue by a 3rd Party Certification Authority that is accompanied by a
digitally created image of your seal and required language.
4. This item has been electronically signed and sealed on the Date and/or Time Stamp shown
using a digital signature.
This letter constitutes a signed and sealed statement attesting to the veracity of the method and software
used to sign and seal the plans and document
Be advised that printed copies of this document are not considered signed and sealed and the signature
must be verified on any electronic copies.
Project
P20-0084 Windows and door replacement
-- Address
w06w NE 9;
kliiam, FL
Content
Digital sign documents
NUMBER PDF FILE
TITLE
AO-0
P20-0084 SD - Sheet - AO-0 - TITTLE SHEET
A-100
P20-0084_So - Sheet - A-100 - Demolition and Proposed Floor Plan
A-200
P20-0084_So - Sheet - A-200 - Demolition and Proposed Elevations
A-503
P20-0084 SD - Sheet - A-603 - Door & Windows
Respectfully.
Digitally signed by Victor R Vega
Sanabria
DN: c=US, o=VRVS-ARQ-FL,
a
ou—A0141 OD0000016BD2B7EAE4000
02B14, cn=Victor R Vega Sanabria
Date: 2020,09.02 21:34:42-04'00'
Victor R. Vega Sanabria, AIA
ONLINE BUILDING PLANS CORP
_iCENSE WMBER AA260a3924
<ery C1e Archi'e » rR- 9771 y
_ _- F L O R I D A PROJECT: P2O-0084
B U I L. D 1 N L_ A N S ADDRESS.1065 NE 97 ST
Content
PROJECTNAME...........................................................................................................................................................1
PROJECTADDRESS......................................................................................................................................................1
WIND LOAD CALCULATION.........................................................................................................................................2
PROJECT NAME
P20-0084
PROJECT ADDRESS
1065 NE 97 ST
ALL STRUCTURES DESIGNED IN ACCORDANCE WITH:
• 2017 FLORIDA BUILDING CODE
• 2017 INTERNATIONAL BUILDING CODE
• ASCE 7-10
F STRUCTURAL REVIEW
APPROVED O. BLANCO
08/04/2020 11:10:13 AM
Digitally signed by Victor R
�Ptt°E.i! go �
�' GA
Vega Sanabria
.a
DIN: c=US, o=VRVS-ARQ-FL,
ou=A0141OD0000016BD2B
9(
7 ii
7EAE400002B14, cn=Victor
R Vega Sanabria
aeo ia�
Date: 2020.07.23 13:32:32
-04'00'
Victor
R. Vega Sanabria, AIA
ONLINE
BUILDING PLANS CORP
-; _ 1
FLORIDA PROJECT. P20-0084
BUILDING PLANS ADDRESS. 1065 NE97ST
WIND LOAD CALCULATION
Wind Anaivsis for Low-rise Building, Based on ASCE 7-2010
INPUT DATA
Exposure category (K C or D, ASCE 7-10 26.7 3)
C
Importance factor (ASCE 7-10 Table 1.5-21,
1, =
1.00 for all Category
Basic wind speed (ASCE 7-10 26.5 1 or 2012 IBC)
V =
175 mph
Basic wind speed (ASCE 7-10 26 5.1 or 2012 IBC)
V =
135,13 mph
Topographic factor (ASCE 7-10 26.8 & Table 26 8-1)
Kzt =
1 Flat
Building height to eave
he =
9 ft
Building height to ridge
hi =
15 ft
Building length
L =
81.75 ft
Building width
B =
56.25 ft
ANALYSIS
Velocity pressure
qh = 0.00256 Kh K,j Kd V2
33.99
psf
where qh = velocity pressure at mean roof height,
In. (Eq. 28.3-1 page 298 & Eq. 30,3-1 page 316)
Kh = velocity pressure exposure coefficient
evaluated at height, h, (Tab 28 3-11. pg 299)
= 0.85
Kd = wind directionality factor. (Tab. 26.6-1. for building, page 250)
0.85
h = mean roof height
= 12.00 ft
* 60 ft, [Satisfactory]
(ASCE 7-10 26.2.1
* Min (L, B), [Satisfactory]
(ASCE 7-10 26.2.2
Design pressures for MWFRS
p = qh [(G Cpf )-(G Cpi )]
where: p = pressure in appropriate zone. (Eq. 28A-1 , page 298). p,,,, = 16 psf (ASCE 7-10 28 4A)
G C,f = product of gust effect factor and external pressure coefficient, see table below (Fig. 28,4-1 , page 300 & 301)
G C, = product of gust effect factor and internal pressure coefficient. (Tab. 26.11-1, Enclosed Building, page 258)
0.18 or -0.18
a= width of edge strips, Fig 28.4-1, note 9, page 301, MAX[ MIN(0.1 B. 0,1L. 0,4h), MIN(0.04B 004L).3] = 4.80 ft
Roof angle o = 12.04 1
2
L� 'FL0RIDA
UILDING PLANS
ADDRESS.1065 NE97ST
Design pressures for components and cladding m
p = qn ) )1
� �..--q
where p=pressure on component. (Eq 30.4-1, pg 318) �4 5 }� 2 i 1 2 r c i12
Pmin = 16.00 psf (ASCE 7-10 30.2.2) i �Ui i
G Cp = external pressure coefficient. s -
Walls
see table below. (ASCE 7-10 30.4.2)
Roof Roof P.
1
2
3
4
5
6
7
6
9
10
tt
12
13
14
16
16
17
A
B
C
D
E
Comp. &
Pressure
Note tfthe effective area is roof Solar Panel area.. the only zone 1, 2 . or 3 apply.
CO
Effective
Area (ftZ}
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
width
heith
GCP
- GCP
GCP
-GCP
GCP
- GCP
GCP
GCP
GCP
-GCP
9.17
4.25
38.96
0.38
-0.84
0.38
-1.40
0.38
-2.25
0.90
-1.00
0.90
-1.19
6.17
4.27
26.34
0.42
-0.86
0.42
-149
0.42
-2.35
0.93
-1.03
0.93
-1.25
6.17
3.25
20.04
0.44
-0.87
0.44
-1.55
0.44
-2.42
0.95
-1.05
0.95
-1.29
4.00
7.00
28.00
0.41
-0.86
0.41
-1.48
0.41
-2.33
0.92
-1.02
0.92
-1,24
6.17
3.25
20.04
0.44
-0.87
0.44
-1.55
0.44
-2.42
0.95
-1.05
0 95
-1.29
3.13
4.25
13.28
0.48
-0.89
0.48
-1.64
0.48
-2.53
0.98
-1.08
0.98
-1,36
3.08
4.25
13.10
0.48
-0.89
0.48
-1.64
0.48
-2.53
0.98
-1.08
0.98
-1.36
3.08
4.25
13.10
0.48
-0.89
0.48
-1.64
0.48
-2.53
0.98
-1.08
0.98
-1.36
6.17
3.21
19.78
0.44
-0.87
0.44
-1.55
0.44
-2.42
0.95
-1.05
0.95
-1.30
3.08
3.27
10.09
0.50
-0.90
0.50
-1.70
0.50
-2.60
1.00
-1.10
1.00
-1.40
9.08
4-13
37.47
0.39
-0.84
0.39
-1.41
0.39
-2.26
0.90
-1.00
0.90
-1.20
3.13
3.25
10.16
0.50
-0.90
0.50
-1.70
0.50
-2.60
1.00
-1.10
1.00
-1.40
3.08
4.25
13.10
0.48
-0.89
0.48
-1.64
0.48
-2.53
0.98
-1.08
0.98
-1.36
3.13
4.29
13.41
0.47
-0.89
0.47
-1.64
0.47
-2.52
0.98
-1.08
0.98
-1.35
1.63
2.21
3 59
0 50
-0 90
0.50
-1.90
0.50
-2.60
1.00
-1.10
L00
-1.40
3.96
2.94
11.63
0.49
-0.89
0.49
-1.67
0.49
-2.56
0.99
-1.09
0.99
-1.38
3-08
3.27
10.09
0.50
-0.90
0.50
-1.70
0.50
-2.60
1.00
-1.10
1.00
-1.40
3.00
6.83
20.5
0.44
-0.87
0.44
-t54
0.44
-2 41
0.94
-1.04
0.94
-1.29
8.00
7.00
56
0.35
-0.83
0.35
-1.33
0.35
-2.15
0.87
-0.97
0.87
-1.14
8.00
Z00
56
0.35
-0.83
0.35
-133
0.35
-2.15
0.87
-0.97
0.87
-1.14
2.75
6.83
18.7917
0.45
-0.87
0.45
-1.56
0.45
-2 44
0.95
-1 05
0.95
-1.30
8.00
7.00
56
0.35
-0.83
0.35
-1,33
0.35
-2.15
0.87
-0.97
0.87
-1.14
Cladding
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
(psf)
Positive
Negative
Positive
Negative
Positive
Ne alive
Positive
Ne ative
Positive
Negative
t
19.10
-34.70
19.10
-53.86
1910
-82.44
36.56
-39.96
36.56
-46.61
2
2025
-35.28
20.25
-56.75
20.25
-85.91
37.58
-40.98
37.58
-48.65
3
21.06
-35.68
21.06
-58.76
21.06
-88.33
38.29
-41.69
38.29
-50.07
4
20.07
-35.19
20.07
-56.30
20.07
-85.36
37.42
-40.82
37.42
-48.33
e
2t06
-35.68
21.06
-58.76
21.06
-88.33
38.29
-41.69
38.29
-50.07
6
2227
-36.29
22.27
-61.80
22.27
-91.97
39.36
-42.76
39.36
-52.22
7
22.31
-36.31
22.31
-61.90
22.31
-92.09
39.40
-42.80
39.40
-52.29
8
22.31
-36.31
22.31
-61.90
22.31
-92.09
39.40
-42.80
39.40
-52.29
B
21.10
-35.70
21.10
-58.86
21.10
-88.44
38.33
-41.72
38.33
-50.14
to
23.09
-36.69
23.09
-63.83
23.09
-94.41
40.08
-43.48
40.08
-53.65
11
19.21
-34.76
19.21
-54.15
19.21
-82.78
36.66
-40.06
36.66
-46.81
t2
23.06
-36.68
23.06
-63.78
23.06
-94.34
40.06
-43.46
40,06
-53.62
t3
22.31
-36.31
22.31
-61.90
22.31
-92.09
39.40
-42.80
39.40
-52.29
t4
22.24
-36.27
22.24
-61.73
22.24
-91.88
39.34
-42.74
39.34
-52.17
t5
23.11
-36.71
23.11
-70.69
23.11
-94.48
40.10
-43.50
40.10
-53.70
16
22.67
-36.48
22.67
-62.78
22.67
-93.15
39.71
-43.11
39.71
-52.91
t7
23.09
-36.69
23.09
-63.83
23.09
-94.41
40.08
-43.48
40.08
-53.65
A
20.99
-35.65
20.99
-58.60
20.99
-8812
38.23
-41.63
38.23
-49.96
B
18.03
-34.16
18.03
-51.18
?8.03
-79.23
35,61
-39.01
35.61
-44.72
C
18.03
-34.16
18.03
-5118
18.03
-79.23
35.61
-39.01
35.61
-4472
D
21.25
-35.77
21.25
-59.24
21.25
-88.90
38.46
-41.86
38.46
-50.41
E
18.03
-34.16
18.03
-51.18
18.03
-79.23
35.61
-39.01
35.61
-44.72
F L 0 R I D A
BUILDING PLANS
7550 2"D CT, HIALEAH, FL 33014
Building department,
Florida Building Plans is currently working on the disapproval remarks defined by the city
on:
Process Number: RC-07-20-1621.
Property address: 1065 NE 97TH ST Miami Shores FL 33138
Owned: Spazio Construction
Florida Building plans is a company of certified architects and engineers that develop
architectural new projects, remodeling and code violation solutions.
For any question regarding the status of the project please contact us at
Phone number: (305)424-9223
In the following document you will find a list with the comments of the corrections
(mechanical, building) and each reviewer found on the Plans Tracking System at the
web page.
y
FLORIDA
BUILDING PLAT
7550 2ND CT, HIALEAH, FL 33014
Building - 08/24/2020
Reviewer: Naranjo Ismael
1. Wood framing not allowed on exterior walls as per Miami Shores Village Code
of Ordinances.
R/ Change in scope of work, wood framing walls to be demolished and
replaced by metal framing. Please see change in SOW on title sheet under
revision cloud #3. See on demolition and proposed floor plan the walls to be
replaced on sheet A-100 under revision cloud #2
New cold -formed steel framing was provided for new exterior walls. See detail
5/A-603 (cloud #2 sheet A-603)
Regards,
of FL Digitally signed by Victor R Vega
C3 '4. o
EGg; Sanabria
o� DN: c=US, o=VRVS-ARQ-FL,
s ou=A0141OD0000016BD267EAE
P�. 91719 400002614, cn=Victor R Vega
Sanabria
SrFRBo Aao� Date: 2020.09.02 21:53:45-04'00'
Victor R. Vega Sanabria, AIA, CSI
Register Architect Lic. AR 97719
ONLINE BUILDINGS PLANS CORP.
License Num: AA26003924
vrveaas@onlinebuildinaolans.com
Direct number: (954) 866 9806
21
PROPERTY INFORMATION
4dd—s" 06- NE
tl-
SITE INFORWTION
--, jf he R.. A"I
oor Elegy:
SCOPE OFWORK— - ----
W
3 1.
i -d fiv 119
APPLICABLECODES
Aril agile �,*, fiO-e
CCOE Bull-IING rLQIIII ILI IMG - H)i MI71
CooL RESIDENT
,,s IDE T 'AL R CRIDA HESID-_NrIAL CODE i20171
CODE PLUMBING FLORIDA 3 - ft �ANG CODE 20171
CODE VECHANICAL: FLC.Q IL�'A 'A CIAMCIL BODE 120171
COC, C—ICAL ,
ELECTRICAL: NATIONAL CODE CIE 201n!
FLOOD MAP
Flom -lap i2j86-"3�&
Fload III,, d
GENERAL
r.
Lvol,
LOTCOVERAGE
Are.
A- 5F
BUILDING HEIGHT
8_Idv,g Heigh
SETBACK REQUIREMENTS
UNDER OTHER PCRMIT
SOUND teANSNIMSION STA
-0 � - Zo - 6r=, 2-)
NAA?A! SHORES VILLAI'�t
APPROVED I BY I DATE
ZONING
STRUCTURAL
ELECTRICAL
PLUMBING I I I
IMECIIAWCAL] I I
BLDG. I -
SUUir"Q'T 10 CLIWLIAN.11 Allil .-LL L, IFF�L
STATE
;%NL) COUNTY RULES AND RU.',
Sheet List
Sheet
Pages Number
Sheet Name
Tffl_r
16
Jt t P'o,0
d
STRUCTURAL REVIEW APPROVED O. BLANCO
08/0412020 11 :18719 AM
18L4
FLORIDA
BUILDING PLANS
7550 CT, HIALEAH, FL 33014
iii _3 E. kevpk:nerq,',yPgt
Na. Description Este
-_,fly signed
P20-0084
',E 47
TITTLE SHEET
6
AO.0Permit Process
WALL PHASES:
- - - - - - - - - - -
R'lirsll—rl 11". 7.211--.
FIRST FLOOR EXIST I NG If DF410 1710"'PLP;
INDICATES EXISM11,VALL �11N4SE
INDICATESLE"OLITIONWAL.A. PHASE
INDIC.ATESTEMPGRARYWALL PHASE
BUILDING REVIEW
APPROVED 1. NARANJO
0812412020 2:54:12 PM
4E� =7-777- F L 0 R I D A
BUILDING PLANS
7550 W 2ND CT, HIALEAH, FL 33014
No._Description Date
4� jJ
4�17 F L 0 R I D A
BUILDING PLANS
7550 W 2ND CT, HIALEAH. FL 33014
2130 ,9
71
No. DescriptJon Date
L7-
Proposed East
—T
L it
FBC 107.2. I. Scope of Work
T
L —i
ti
� kx''\
--- ----- — bi v'm' IY g'
RA ARQ-'�
I 10N31 II
TL�'- P20-0084
JI,5 '.E ,' S
Demolition and Proposed
Elevations
-Z zC-1 32
A-200
Pe —it Process
Windows Legends
T- 2"
1 2',.
3 Z
9 10 11 12, 13 14
EGRESS EGRESS
14
35
Door Legend
SLIDING DOOR
101 102
16
1029.2 Minimum
size,
3
wrdoX
0810 00 - DOOR �&F IiMES SCHEDULE
D— Dimensm
lark Door Description VIRdth HIeWt e NOA NUMBER
4
7
20'
1029.2,1 Min ,,m d,,
N
EK,,pe Door-namum overTA d1Rrenslf`5
08 50 00 - WINDOW SCHEDULE
Marc Window Description
vu'dows Dimension
VKM I Height Zone�
PDP,
Impact
PDP-� Resistant
1 Egress
1Compiiance
SHGC
U FACTOR
NOA
J
31
Z5
31
Y,
N'-' .0 -e sell -;..A D,
Dv
il1—t—p � I
"--at
Y.
d
2z
NCA
3 t
d -v
-Vv� J
- — - — — — — - — — — — — —
DESIGN CRITERIA
E �.E� F,ORIDA SUILDINOCC;DE 201'
ASGE ?-1-)
BASIC HIND SPEED ;V i13-175MPH
"GIANAIDESIONIMN�DSPEED V-1-36 MPH
-EXPOSURE GATEGORY= C,
iNTERNAL PRESSURE COEFFICIENT= , -0 IS
:13JILDING CATEGORY 11
11 PR—jid,
luv u
171"SLIDING F OCR -ATTACHM&IT DIAGRAM
x
II v
1029.2
Minimum
(5
size.
5.70 sq.ft.
X
<
X
oo._.
1 4
MAX DOOR FRAME WIDTH 97'
BEARING NALL DETAIL ,CI'l-D-FORIMED STEEL
FRAMING,
SIX HEADER,
12 SECTION OF STUD SAME
GAUGE AND SIZE AS TRACK
TRACK-.-
-SCREW ATTACH BOTH ENDSOF •SIMPSON STRONG TIE SHH3.66
TYPICAL TRACKS TO SHORT LA��fl SIDE Of 1IFADER LAGH
SECTION OF STUD W N 5� 410-16 CGREWS 70 JAMB
#10-16 SCREWS PER STUD 1 6! �10-16 SCREWS 7.0
FLANCE.EA SIDE OF SPLICE AQER i,('C�ATED AS SHL*VvJN
BOTTOM TR-�CK SPLICE HEADERNAMB STUD CONNECTIC-1
--------------
A 603
e A;-FLORIDA
Pt- 7
BUILDING PLANS
50 W 2N1) CT. HIALEAH, FL 33014
E ,vJa
Description
Dale
PROPERTY INFORMATION:
Compliance Method FBCE 2017:
b; Vega
San�bna
01.
- VS-AHQ-cL
32
Branch Panel: Existing Panel
Project Nam, -2D jG84
Lm tion vofm�n�s� A.I.C. Rating Su --
poly fro Phase ' MarnsType: MLC
Mounting:'.Recessed Wires: 3 MansRaung! A
Enclosure, Bus Rating:
Not— A21 sectr-1 ex sv,g Only 1- gli,q Iddea or east ng spaec,—,
Total Conn. Load 33724 VA
ARC FAULT PROTECTED RECEPTACLES AS PER NEC...
------------- - --
LgNinq- Pjrsq Flooc
ELECTRICAL LEGEND
WIRING DEVICE
jas IFF
jVFD AT,4 AFF
JU INTED AT 48'Wi7
T 'PHASE. I "PZ fiAL
�T!8-AFF
—,-PTACL- -'Z, VC--T.' PHASE 3 WIRE WAL,
ED- P-AC1- 240'iOLT.' PHASE 4WIRE WALL. EX �L- 0 - KE�TACU� -,-,ie0UND PALT --%101.- 1 PHASE
h,IP C AT '8- AFF NAi V(DUK ,
121 ICL- !FHASE
VOUNT.13 AT ;8 AFF
FEPNEC440.14614EC440.22
IX RE
x nor
`tAL -Al
FIRE ALARM DEVICE
A'
--e Dc-- 20 ILA 1 Ph.e 3 CIffing tru, 10
ltsrc,je De' -b 2T 1cft I Ph— 3 ff,. Gr f-I
LIGHTING FIXTURE
POWER EQUIPMENT se "'fr's )L; Jd
Elrclncal
Ira
^al I
PHASES
EXISLINC, TO REMAIN
A
F L 0 R I D A
BUILDING PLANS
7550 W 2ND CT, HIALEAH, FL 33014
F3C 1071A, Scope of Work
Digitally ,go, d Victor R Vsq.
Sar,,bna
11* DN�c -US.
o =IVI-AIQ-FL.
niu
01410DOOO
016BD2B7EAE40,
002914. "n -Via'-
R Vegu S—,b-
D,ate: 2020,09 0'
21 5 5:; 1 -04-00
'FLORIDA PROJECT: P20-0084
BUDDING PLANS ADDRESS. 1065 NE97ST
Co me nt
PROJECTNAME...........................................................................................................................................................1
PROJECTADDRESS......................................................................................................................................................1
WINDLOAD CALCULATION.........................................................................................................................................2
COLD -FORMED STEEL FRAMING DESIGN.....................................................................................................................4
COLD -FORMED STEEL HEADERS DESIGN ....................... _............................................................................................. 7
PROJECT NAME
P20-0084
PROJECT ADDRESS
1065 NE 97 ST
ALL STRUCTURES DESIGNED IN ACCORDANCE WITH:
• 2017 FLORIDA BUILDING CODE
• 2017 INTERNATIONAL BUILDING CODE
• ASCE 7-10
-
Digitally signed by Victor R
°E q� °R,a
Vega Sanabria
y o
DN: c=US, o=VRVS-ARQ-FL,
p.
';,
ou=A01410D0000016BD2
» 9
B7EAE400002614,
,+'°
STFRE
cn=Victor R Vega Sanabria
. Aac
Date: 2020.09.02 21:48:11
-04'00'
Victor R, Vega Sanabria, AIA
ONLINE BUILDING PLANS CORP
01
F L 0 R I D A
BUILDING PLANS
WIND LOAD CALCULATION
PROJECT. P20-0084
ADDRESS: 1065 NE97ST
Wind Analysis for Low-rise Building, Based on ASCE 7-2010 1
INPUT DATA
Exposure category fB. C or D ASCE 7-10 26 7,3)
C
Importance factor (ASCE 7-10 Table 1 5-2)
1, =
1.00
for 211 Category
Basic wind speed (ASCE 7-10 26 51 or 2012 )BC)
V =
175
mph
Basic wind speed (ASCE 7-10 26.5 1 or 2012 113C)
V =
135.6
mph
Topographic factor (ASCE 7-10 26,8 & Table 26 8-1
K,, =
1
Flat
Building height to eave
he =
9
ft
Building heightto ridge
h, =
15
ft
Building length
L =
81,75
ft
Building width
B =
56.25
ft
ANALYSIS
Velocitv oressure
qt, = 0.00256 Kt, K7t Kd V2 33.99 psf
where qh = velocity pressure at mean roof height. h. (Eq, 28 3-1 page 298 & Eq. 30,3-1 page 316)
K1, = velocity pressure exposure coefficient evaluated at height, h. (Tab 28 3-1, P9 299) = 0.85
Kd = wind directionality factor. (Tab. 26,6-1, for building, page 250) 0.85
h = mean roof height = 12.00 ft
* 60 ft, [Satisfactory] (ASCE 7-10 26,2, 1)
* Min (L, 13), [Satisfactory] (ASCE 7-10 26 2 2)
Design oressures for ll
p = qh [(G Cpf )-(G Cpj )]
where p = pressure in appropriate zone. (Eq. 28.4-1. page 298). p, ,,I,, = 16 psf (ASCE 7-10 28AA1
G Cpf = product Of gust effect factor and external pressure coefficient see table below. (Fig. 28.4-1, page 300 & 301)
G C, = product of gust effect factor and internal pressure coefficient(Tab. 26,11-1, Enclosed Building, page 258)
0.18 or -0.118
a= width of edge strips, Fig 28 4-1. note 9. page 301. MAX[ IMIN(0,113.0,11- 0.4h).MIN(0,04Br0,04I-),3] = 4.80 ft
Roof angle o = 1204 1
PA
FLORIDA
BUILDING PLANS
ADDRESS:1065 NE97ST
Design pressures for components and cladding 3 2 - ;, s 1- j 2- 7I
p = qh[ (G Cp) - (G CPA
- p ( ) N N where: p = pressure on component. (Eq. 30.4-1, pg 318) z I 2,pmin 1600 sf ASCE 7-10 30.2.2
I -
G Cp = external pressure coefficient. _ - z - s : z '-
Walls �- -
see table below. (ASCE 7-10 30.4.2)
Roof Roof
P.
Pressu
Note:
If the effective
area is
roof Solar
Panel area.
the only
zone 1. 2
. or 3 apply.
Corn
Effective
Area (ftZ)
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
width
heith
GCP
•GCP
GCP
-GCP
GCP
-GCP
GCv
-GCP
GCP
-GCP
5
re (psf)
Positive
Ne alive
Positive
Negative
Positive
Negative
Positive
Negative
Positive
Negative
1
19.10
-34.70
19.10
-53.86
19.10
-82.44
36.56
-39.96
36.56
-46.61
2
20.25
-35.28
20.25
-56.75
20.25
-85.91
37.58
-40.98
37.58
-48.65
3
2106
-35.68
2L06
-58.76
21.06
-88.33
38.29
-4169
38.29
-50.07
a
20.07
-35.19
20.07
-56.30
20.07
-85.36
37.42
-40.82
37.42
-48.33
5
21.06
-35.68
21.06
-58.76
21.06
-88.33
38.29
-41.69
38.29
-50.07
5
22.27
-36.29
22.27
-61.80
22.27
-91.97
39.36
-4276
39.36
-52.22
7
22.31
-36.31
22.31
-61.90
22.31
-92.09
39.40
-42.80
39.40
-52.29
6
22.31
-36.31
22.31
-61.90
22.31
-92.09
39.40
-42.80
39.40
-52.29
s
21.10
-35.70
21.10
-58.86
21.10
-88.44
38.33
-41.72
38.33
-50.14
10
23.09
-36.69
23.09
-63.83
23.09
-94.41
4008
-43.48
40.08
-53.65
11
19.21
-34.76
19.21
-54.15
19.21
-8278
36.66
-40.06
36.66
-46.81
12
23.06
-36.68
23.06
-63.78
23.06
-94.34
40.06
-43.46
40.06
-53.62
13
22.31
-36.31
22.31
-61.90
22.31
-92.09
39.40
-42.80
39.40
-52.29
14
22.24
-36.27
22.24
-61.73
22.24
-9188
39.34
-42.74
39.34
-52.17
15
23.11
-36.71
23.11
-70.69
23.11
-94.48
40.10
-43.50
40.10
-53.70
16
22,67
-36.48
22.67
-62.78
22.67
-93.15
39.71
-43.11
39.71
-52.91
17
23.09
-36.69
23.09
-63.83
23.09
-94.41
40.08
-43.48
40.08
-53.65
A
2099.
-35.65
20.99
-58.60
2099
-88.12
38.23
-41 .63
38.23
-49.96
B
18.03
-34.16
18.03
-51.18
18.03
-79.23
35.61
-39.01
35.61
-44.72
c
18.03
-34.16
18.03
-51.18
18.03
-79.23
35.61
-39.01
35.61
-44.72
D
21.25
-35.77
21.25
-5924
21.25
-88.90
38.46
-41.86
38.46
-50.41
E
18.03
-34.16
18.03
-51.18
18.03
-79.23
3561
-39.01
35.61
-44.72
3
F L 0 R I D A
BUILDING PLANS
COLD -FORMED STEEL FRAMING DESIGN
I77-FLORIDA
BUILDING PLANS
PROJECT. P20-0084
ADDRESS.1O65 NE97ST
(Wall Stud Design Based on AISI S100/SI-10 & ICBO ER-4943P
INPUT DATA & DESIGN SUMMARY
SECTION & SPACING 600S137-33 - @
16
in o.c
WALL HEIGHT h=
11
It
hp=
0
ft
}
GRAVITY LOAD (ASD level) P =
400
Ibs /ft
LATERAL LOAD (SD level) wi =
33.98
psf
y
PARAPET LOAD (SD level) w2 =
0
psf
ECCENTRICITY e=
0
in
DEFLECTION LIMITATION ?
2
h /360
(O=No., 1= h /240, 2= h /360, 3= h /180, 4= h /120)
-
THE DESIGN IS ADEQUATE.
ANALYSIS
SECTION PROPERTIES OF EACH METAL STUD (SSMA page 7 & 8)
thk = 0.0346 in Fy =
33
ksi
Ixx = 1,582 in4 Mn/Qb = 10.07 in -kips
t = 6 in Wt =
1.08
lb/ft
Sxx = 0.51 in3 Vn/Qv= 612 Ibs
A = 0.318 192 rx =
2.229
in
ry = 0,464 in xo = -0,823 in
J = 0.00013 in CW =
0,493
in6
CHECK MAX WEB DEPTH -TO -THICKNESS RATIO (AISI
B1.2)
t / (thk) = 173,41 < 200
[Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
M„ 10b = 10.07 in -kips / stud > M [Satisfactory]
- -
Where (hh'' I Pc ; - 5.50 ft
2h h;.l;.
1
(h_-h;.) S= 8.22 in-kips/stud
21r,h 2
S = 1.333 ft o.c . spacing as gaven.
0,00 in -kips I stud
p
M = (1/1.4) MAX( MI
M2) = 5.87 in -kips / stud. (111.4 for wind/seismic, from AISI App A4.1.2, typical)
CHECK SHEAR CAPACITY (AISI C3.2)
V❑/SiV = 612 Ibs / stud
> V [Satisfactory]
(h,lr,-)�r I'e
Where f (h ` h, u, - -
249 Ibs / stud
2h h=
V2 = h w, S - V, =
249 Ibs / stud
V3 = hp W2 S =
0 lbs i stud
V = (1/1.4) MAX(Vj
, V2 , V3) = 178 Ibs / stud
CHECK CAPACITY COMBINED BENDING & SHEAR AT ROOF/FLOOR SECTION (AISI C3.3.1)
=
0.2908 < 1.0 [Satisfactory]
Where M = 0.00
in -kips / stud. (1/1 4 included)
V = 178
Ibs / stud, (111.4 included)
Vn/Q,,.= 612
Ibs / stud, from SSMA page 7 & 8.
Mn/f lb = 10.07
in -kips / stud... from SSMA page 7 & 8.
FL0RIDA
BUILDING PLANS
PROJECT: P20-008
ADDRESS.1065 NE97ST
(cont'd)
h = 0.00 < 0.5 c2l.t, = 0.29 < 0.7
0.6�
n/yl1t'i - 0.2908 < 1.3 [Satisfactory]
'v P1t
CHECK COMPRESSION CAPACITY WITH, AT LEAST, ONE FLANGE THROUGH -FASTENED TO SHEATHING (AISI D6.1.3)
Pn1Qc = 2.68 kips / stud > P [Satisfactory]
Where S2c = 1.8
Pn = C1C2C3 AE / 29500 = 4.82 kips / stud
C1 = (0.79 .\ + 0.54) = 0.949
C2 = (1.17 u.. t + 0,93) = 0.970
C3 = a (2.5b - 1.63d) + 22.8 = 16.445
E = 29500 ksi (AISI pg xiv)
P = 0.67 kips / stud (included wall weight, 18psf.)
CHECK CAPACITY COMBINED AXIAL LOAD & BENDING (AISI C5.2.1)
0.86 < 1.0 [Satisfactory]
P11 11 d1l
Where M = 5.87 in -kips / stud, (1/1.4 included)
P = 0.67 kips / stud
Pn/o, = 2.68 kips / stud
Mn/Qb = 10.07 in -kips J stud
Cm= 1.0
PF-, _ = 26.44 kips / stud
(K:10-
0.955
CHECK DEFLECTION
5(11IS)L4
A _ = 0.32 in < h /360 = 0.37 in [Satisfactory]
384EI.t.,
NOTE: 1. STUD FLANGES SHALL BE FASTENED TO SHEATHING AT EACH SIDE OF WALL BEFORE VERTICAL LOAD ADDED.
Technical References:
1. AISI S 100/SI-10. North American Specification for the Design of Cold -formed Steel Structural Members, with Supplement 1. 2010.
2. SSMA, Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.
2
F L 0 R I D A
E�UILDING PLANS
COLD -FORMED STEEL HEADERS DESIGN
PROJECT P20-0084
ADDRESS: 1065 NE97ST
FLORIDA
BUILDING"
Box Beam Desi n Based on AISI S100/SI-10 & ICBO ER-4943P
INPUT DATA & DESIGN SUMMARY
VERT MEMBERS 2 x 1000S162-54
(TOTAL SECTION: 4 x 10 50 ksi )
SPAN L= 6 ft
DEAD LOAD DL = 0.2 kips/ft
LIVE LOAD ILL = 0.2 kips/ft
r
WIND WL= 0.17 kips/ft
COMPRESSION FLANGE SUPPORTED ? (O=No. 1=Yes) 0 No.
PROJECT. P20- 084
ADDRESS.1O65 NE97ST
DEFLECTION LIMITATION FOR LIVE LOAD ? 1 L /240
(O=No., 1= L /240, 2= L /360, 3= L /180, 4= L /120) THE DESIGN IS ADEQUATE.
ANALYSIS
SECTION PROPERTIES OF EACH STUD (SSMA page 7 & 8)
t = 0.0566 in Fy = 50
ksi Ixx
4
= 9.95 in
h = 10 in Wt = 2,66
Ib/ft Sxx
= 1,712 in3
A = 0.783 in rx = 3.565
in ry
= 0.511 in
J = 0.00084 in CW = 4,16
in6
CHECK MAX WEB DEPTH -TO -THICKNESS RATIO (AISI61 2)
h / t = 176,68 < 200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
Mn/12b = 8,54 ft-kips > M
[Satisfactory]
Where M=(DL+LL+Wt)L2/8= 1,82
ft-kips
M = (WL + Wt) L2 / 8 = 0.78
ft-kips
CHECK SHEAR CAPACITY (AISI C3.2)
Vn/0V = 3.19 kips > V
[Satisfactory]
Where V=(DL+LL+Wt)L/2= 1.22
kips
CHECK LATERAL -TORSIONAL BUCKLING (AISI C3.1.2.2)
0.36Chr,
0.79 ft
< L
Where Cb = 1 0
Sf= 398 in (total vertical studs, SSMA page
7 & 8.)
E = 29500 ksi (AISI pg xiv)
G = 11300 ksi (AISI pg xv)
I = 4.936 in° (neglecting top
& bottom tracks conservatively.)
J = 0.002 in
b T F J 18.2
ksi <
2.78 Fy =
h )`i.f' /
<
0.56 Fy =
Where Ky = 1.0
Ly = 72 in
F, for Fe->2.78)-,
IOFp10
?7sFF1_'i eo_6Fy9 _
18.2 ksi
6ei
-
Fe fbr Fe_<O.i6F1.
1 51.26 in -kips
Vn/S2 = 1593 Ibs
xo = -0.827 in
139.0 ksi
28.0 ksi
n
F L 0 R I D A
BUILDING PLANS
PROJECT: P20-0084
ADDRESS.1065 NE97ST
(co
M„/Ob = 3.61 ft-kips
>
M [Satisfactory]
Where Sc = 3.98
in3 (total
vertical studs.. SSMA page 7 & 8.)
«b= 1.67
Mn = ScF� =
72.37
in -kips
M=(DL+LL+Wt)L2/8=
1.82 ft-kips
CHECK CAPACITY COMBINED BENDING & SHEAR AT
ANY SAME SECTION (AISI C3.3.1)
0,633
< 1.0 [Satisfactory]
r19n - �'rr
Where M = '1.82
ft-kips
V = '1.22
kips
Vn1Q,= 3.19
kips
C2b = 1.67
Mn = MIN(Bending
, Buckling) =
6.03 ft-kips
Mn/i2b =
8.54
ft-kips, for bending only.
�12/04 1
= 0.51
>
0.5 «l.i' '� c 0.38 < 0.7
06, 'b/ �'I =
0.6847
< 1.3 [Satisfactory]
t 11n ,Vn 1
CHECK DEFLECTION
5(LL)L4 0.01 in < L /240 = 0.30 in [Satisfactory]
1[Z. - 384E_/
Technical References:
1. AISI S100/SI-10, North American Specification for the Design of Cold -formed Steel Structural Members. with Supplement 1. 2010.
2. SSMA. Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.
9
1
F L 0 R I D A
BUILDING PLANS
PROJECT: P20-0084
ADDRESS.1065 NE97ST
Box Beam Design Based on AISI S100/SI-10 & ICBO ER-4943P
INPUT DATA & DESIGN SUMMARY
VERT. MEMBERS 2 x 1000S162-97 -
r
(TOTAL SECTION: 4 x 10, 50 ksi )
SPAN L= 9 It
r
DEAD LOAD DL= 0.2 kips/ft
LIVE LOAD LL = 0.2 kips / ft
r
WIND WL= 0.17 kips / ft
COMPRESSION FLANGE SUPPORTED ? (O=No. 1=Yes) 0 No.
DEFLECTION LIMITATION FOR LIVE LOAD ? 1 L /240
(O=No., 1= L /240, 2= L /360, 3= L /180, 4= L /120) THE DESIGN IS ADEQUATE.
ANALYSIS
SECTION PROPERTIES OF EACH STUD (SSMA page 7 & 8)
t = 0.1017 in Fy = 50 ksi Ixx =
16.967 in
h = 10 in Wt = 4.67 Ib/ft Sxx =
3.393 in
A = 1.372 in2 rx = 3.516 in ry =
0.483 in
J = 0.00473 in4 CH, = 6.708 ins
CHECK MAX WEB DEPTH -TO -THICKNESS RATIO (AISI B1.2)
h / t = 98.33 < 200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
Mn/S3b = 20.06 ft-kips > M [Satisfactory]
Where M = (DL + LL + Wt) L2 / 8 = 4A 4 ft-kips
M = (WL + Wt) L2 / 8 = 1.75 It -kips
CHECK SHEAR CAPACITY (AISI C3.2)
VnQV= 18.92 kips > V [Satisfactory]
Where V=(DL+LL+Wt)L/2= 1.84 kips
CHECK LATERAL -TORSIONAL BUCKLING (AISI C3.1.22)
0.30(.'/r�T 1.46 It< L
Lii = EtiJl i; _
F,,S
Where Cb = 1.0
Sf= 6.79 in3 (total vertical studs: SSMA page 7 & 8.)
E = 29500 ksi (AISI pg xiv)
G = 11300 ksi (AISI pg xvi)
ly = 8.776 in (neglecting top & bottom tracks conservatively.)
J = 0.009 in4
J e = C F7 F(r`.I 22.6 ksi <
2.78 Fy =
K yLYS f
<
0.56 Fy =
Where Ky = 1.0
Ly = 108 in
F't' _for Fe=2.78Fi,
r r o
Fc— 19 F ,I I-36F' ( for 2.78>Fe>_0.-56F3; _
22.6 ksi
e ;
IF, - for FQ<_0.56F,7
Mnlf'b= 120.37 in -kips
VrA)v= 9461 Ibs
xo = -0.795 in
139.0 ksi
28.0 ksi
10
F L 0 R I D A
BUILDING PLANS
PROJECT P20-0084
ADDRESS.1065 NE97ST
M„/0b= 7.64 ft-kips
>
M [Satisfactory]
Where Sc = 6.79
in3 (total
vertical studs.. SSMA page 7 & 8,)
Qb = 1.67
Mn = ScFc =
153.04
in -kips
M=(DL+LL+Wt)LZ/8=
4.14 ft-kips
CHECK CAPACITY COMBINED BENDING & SHEAR AT
ANY SAME SECTION (AISIC3.3.1)
�s1,J
c2�a� =
0.5514
< 1.0 [Satisfactory]
Where M = 4.14
ft-kips
V = `1.84
kips
Vn/51v= 18.92
kips
r'b= 1.67
Mn = MIN( Bending Buckling) =
12.75 ft-kips
Mn/Qb =
20.06
ft-kips, for bending only.
� �Ir14
= 0.54
>
0.5 c7,.t = 0.10 < 0.7
L1rt �
t",r
0.6, �frtf i,l -
0.423
< 1.3 [Satisfactory]
CHECK DEFLECTION
5(L L)L4 0.03 in < L /240 = 0.45 in [Satisfactory]
ALL — 3)84EI
Technical References:
1. AISI S100/SI-10. North American Specification for the Design of Cold -formed Steel Structural Members. with Supplement 1, 2010,
2. SSMA. Product Technical Information, ICBO ER-4943P. Steel Stud Manufactures Association. 2001.
(cont'd) l
11
f1I
FL0RIDA
BUILDING PLANS
Box Beam Design Based on AISI S700/SI-10 & ICBO ER-4943P
INPUT DATA & DESIGN SUMMARY
VERT MEMBERS 3 x 1000S250-97
(TOTAL SECTION: 8 x 10, 50 ksi )
SPAN L= 12 ft
r
DEAD LOAD DL = 0.2 kips /ft
PROJECT. P20-0084
ADDRESS:1065 NE97ST
LIVE LOAD LL= 0.2 kips/ft
r
WIND WL= 0.17 kips/ft
COMPRESSION FLANGE SUPPORTED ? (O=No. 1=Yes) 0 No.
DEFLECTION LIMITATION FOR LIVE LOAD ? 1 L /240
(O=No., 1= L /240, 2= L /360. 3= L /180, 4= L /120) THE DESIGN IS ADEQUATE.
ANALYSIS
SECTION PROPERTIES OF EACH STUD (SSMA page 7 & 8)
t = 01017 in Fy = 50 ksi Ixx
= 21,827 in4
h = 10 in Wt = 5.36 Ib/ft Sxx
= 4.181 in3
A = 1.576 in2 rx = 3.722 in ry
= 0,825 in
J = 0,00543 11`14 CW = 21.268 in6
CHECK MAX WEB DEPTH -TO -THICKNESS RATIO (AISI B1.2)
h / t = 98,33 < 200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
Mn/Elb = 35.16 ft-kips > M [Satisfactory]
Where M = (DL + LL + Wt) LZ / 8 = 7.49 ft-kips
M=(WL+Wt)L'I8= 3.12 ft-kips
CHECK SHEAR CAPACITY (AISI C3.2)
Vn/0V = 28.38 kips > V [Satisfactory]
Where V = (DL + LL + Wt) L / 2 = 2-50 kips
CHECK LATERAL -TORSIONAL BUCKLING (AISI C3 1 2.2)
0.36(,'1r7
F1:Sf
Where Cc = 1.0
Sr= 13.10 n3 (total vertical studs SSMA page
7 & 8.}
E = 29500 ksi (AISI pg )ov)
G = 11300 ksi (AISI pg xA)
ly = 35.760 in4 (neglecting top & bottom tracks conservatively.)
J = 0,016 in4
t'hrr
1 , = -1 .1 J = 23.2 ksi <
2 78 Fy =
1ti ti'LY'�.�
<
0.56Fy, _
Where Ky = 1 0
Ly= 144 in
I- ,lor Fe>2.781-�.
IOF
I9
Fc. F1'� I 36 fnr 2.78>Fe-0.56/:'�, =
Fe
23.2 ksi
Fe .for Fe=0.%F-j,
M❑/f2b = 140.63 in -kips
V02v= 9461 Ibs
xo = -1-491 in
139.0 ksi
28.0 ksi
12
FLORIDA
BUILDING PLANS
M„ 1b = 15.17 ft-kips > M [Satisfactory]
Where Sc = 13.10 in3 (total vertical studs.. SSMA page 7 & 8.)
+2b= 1.67
M = ScFc = 304.10 in -kips
M = (DL + LL + Wt) Lz / 8 = 7.49 ft-kips
PROJECT: P20-0084
ADDRESS.1055 NE97ST
CHECK CAPACITY COMBINED BENDING & SHEAR AT ANY SAME SECTION (AISI C3.3.1)
2� Al S> .1, -'
0.5013 < 1.0 [Satisfactory]
1�7 J'rr
Where M = '7.49 ft-kips
V = '2.50 kips
Vr,/S2v= 28.38 kips
�Ib= 1.67
Mn = MIN( Bending . Buckling) = 25.34 ft-kips
M 112b = 35.16 ft-kips, for bending only.
i2/r1f `
= 0.49 < 0.5 r2 J = 0.09 < 0.7
0.61 0.3841 < 1.3 [Satisfactory]
CHECK DEFLECTION
5(L L)L4 0.05 in < L /240 = 0.60 in [Satisfactory]
ALL 8]EI
Technical References:
1. AISI S100/SI-10. North American Specification for the Design of Cold -formed Steel Structural Members. with Supplement 1, 2010.
2, SSMA, Product Technical Information, ICBO ER-4943P. Steel Stud Manufactures Association, 2001.
13
FLORIDA
BUILDING PLANS
7550 2ND CT, HIALEAH, FL 33014
Building Department,
Florida Building Plans is currently working on the disapproval remarks defined by the city
Permit Number: WS-07-20-1390
Property address: 1065 NE 97 street Miami, FL
Florida Building plans is a company of certified architects and engineers that develop
architectural new projects, remodeling, and code violation solutions.
For any question regarding the status of the project please contact us at
Phone number: (305)424-9223
In the following document you will find a list with the comments of the corrections
(building and structural) and each reviewer found on the Plans Tracking System at the
web page.
STRUCTURAL
1-PROVIDE SITE SPECIFIC WIND LOAD CALLS OR A GENERIC WIND LOAD CALC USING WORST CASE
LOADING IN COMPLIANCE WITH THE HVHZ PROVISIONS OF SECTION 1620, OF THE FBC 6TH EDITION
,2017), SIGNED & SEALED BY FLORIDA REGISTERED ARCHITECT OR ENGINEER, TO DETERMINE THE
MAXIMUM WIND DESIGN PRESSURE FOR ALL EXTERIOR DOORS AND WINDOWS, SKYLIGHTS, STORE
FRONT SYSTEM AND/OR SHUTTERS
Answer„ ACCORDING WITH SECTION 1620,2 OF THE FBC 6TH EDITION (2017) WE CALCULATED THE MAXIMUM
WIND DESIGN PRESSURE FOR ALL EXTERIOR DOORSAND WINDOWS, SKYLIGHTS, STORE FRONTSYSTEM
AND/OR SHUTTERS, WITH A BASIC WIND SPEED= 1 75MPH, NOMINAL DESIGN WIND SPEED =136MPH,
IMPORTANCE FACTOR=1.0, EXPOSURE CATEGORY C INTERNAL PRESSURE COEFFICIENT= +/-0.18, BUILDING
CATEGORY 11 (SEE SHEETA-602 CLOUD #1) (ALL ELEVATION HAVEA TAG WITH THE WIND PRESSURES)
11 Page
||
/1
/
F L 0 R | D A
BUILDING D|NG PLANS
NS
2-STRUCTURAL WIND LOAD CALC'S REQUIRED TO COMPLY WITH FLORIDA ADMINISTRATIVE CODE
SECTION 61G15-23. ORIGINAL SIGNATURE, DATE AND SEAL ARE REQUIRED ON BOTH SETS
Answer: WIND LOAD CALCULATIONS WILL BE ATTACHED WITH THE SHEETS
r1DtOT17M
l, The scope of the work reflected on the plans includes alterations other than window and door
replacement. Provide permit application for master permit and all other related work. The plans
should comply with the requirements of section 107.2 of the 2017 FBC, Building and section 8-10 of
Miami Dade County Code based on compliance method selected frorn section 301 and level of
alteration per section 50lofthe ZDl7FB['Existing Building.
Answer: Plans will be submitted under a master permit application
Digitally signed byVictor RVega
Sanabria
DN:c=US^
ou=A01410D0000016BD287EAE
40O002Bl4'cn=VictorRVega
Sanabria
Victor R. Vega Sanabha./41/\
ONLINE BUILDING PLANS CORP
LICENSE NUyNBERiAA2S0O3924
Register Architect # AR- Q771Q