EL-6-18-1694, 1284 NE 94 St`SgoREV 9 4 nu Project Address Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Parcel Number Applicant 1284 NE 94 Street 1132050100140 Miami Shores, FL Block: Lot: SUZANNE JACOBS Owner Information Address SUZANNE JACOBS 1284 NE 94 ST MIAMI SHORES FL 33138-2947 Contractor(s) Phone Cell Phone AJL ELECTRIC INC 305-895-4971 ype of Work: INSTALL TANKLESS WATER HEATER REMOV dditional Info: INSTALL TANKLESS WATER HEATER REMOV lassification: Residential canning: 1 Fees Due Amount CCF $0.60 DBPR Fee $2.25 DCA Fee $2.00 Education Surcharge $0.20 Permit Fee - Additions/Alterations $150.00 Scanning Fee $3.00 Technology Fee $0.80 Total: $158.85 Phone Cell LValuation0l Sq Feet- 0 Pay Date Pay Type Amt Paid Amt Due Invoice # EL-6-18-67995 06/21/2018 Credit Card $ 108.85 $ 50.00 06/20/2018 Credit Card $ 50.00 $ 0.00 Avarlanie Ins Inspection Type: Final Meter Box Alteration Relocation Fire Alarm Service Change Review Electrical W. W. Underground In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify t at all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction ano-zoning. Faather4re, I authorize the above -named contractor to do the work stated. June 21, 2018 l�thorized Sir4atur� Owner / Applicant / Contractor / Building Department Copy June 21, 2018 Miami Shores Village RECEIVED Building Department SUN 20�� 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (30S) 79S-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 201— -7 BUILDING Master Permit No. �� 19- 2- PERMIT APPLICATION Sub Permit No. ❑BUILDING Vt'LECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP (� CONTRACTOR DRAWINGS JOB ADDRESS: /0,' rs-� City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: /FFFE: /� OWNER: Name (Fee Simple Titleholder): SL-l-Za4/2r (T— C DO;C`Fll / Phone#: 3o 9 I SV -V ('� Address: y�/ `Z�- 19 C � `-'/ V--_'� -�- City: / ' l l ` If! _� [� carp S State: �� Zip: _ Tenant/Lessee Name: Email: <-//> r, one#: CONTRACTOR: Company Name: `� G' nL �-��"�7� C' S� C Phone#:�U� �QS Address: �v� sS s �/ C Aylvt_� /01.,. (JZ� DwX�o City: Al - M f A ^4 1 State: r �- O x / 00�q Zip: 3.3 / 91 Qualifier Name: '447-'f c,.Jq --r "Po Phone#: �3 4-7 f State Certification or Registration #: E e /Soo a0 ff IF Certificate of Competency #: DESIGNER: Architect/Engineer: Add one#: City: State: Zip: Value of Work for this Permit: $ i 6o • v v Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace Description of Work: ❑ Demolition �nlS'Tiac.c_ I ri•JK �cSs W L< ('-� II2 �1 e A-Ct�i2 CM o UG (% v uv I. fi C lit C 1 l i 1 e r T>eet W n 5 4j � Specify color of color thru tile: M L / 1-t-o aye I �� n Submittal Fee $ Permit Fee $ ee--�' CCF $ CO/CC $ Scanning Fee $ Technology Fee $. Structural Reviews $ Radon Fee $ 2 • C7-) DBPR $ QC Notary $ Training/Education Fee $ Double Fee $ _ Bond $ Vi (Revised02/24/2014) TOTAL FEE NOW DUE $ Bonding; Company's Name (if applicable) Bonding; Company's Address City State Mortgage Lenders Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with on estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien low brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. ASignature "TokG�Signature WNER or A N CO ACT R The Foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of d ^« 20 I by (90"� day of 20 IS by pf[�- �! �.1'�•� who is personally known to ��%���Y (.tl�u ��yho is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: <;�7;77;>1 v.4A ;�VA17 as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: MY COMMISSION # FF199225 Seal: "e" ✓-V e W"W v" Seal: �pAY Pu Notary Public State of Flonda ?° Sindis Alvarez a, My Commis^sian/�F�Fq 158750 APPROVED BY 2d—& ✓ %g Plans Examiner Zoning as Structural Review Clerk (Revisec102/24/2014) GILLER RESIDENCE 1284 NE 94T" STREET LOAD CALCULATION GENERAL LIGHTING ................................. 3000 SF X 3 SMALL APPLIANCE & LAUNDRY..............3000 SF X 2 LAUNDRY................................................... 3000 ►101wi 9000 6000 3000 18000 VA REFRIGERATOR............................................................. 900 RANGE.............................................................................1150 MICROWAVE.................................................................. 1000 DISHWASHER..................................................................1200 TANKLESS WATER HEATER..........................................23000 JACUZZI............................................................................ 667 DEMAND FACTOR FIRST 10,000 VA @ 100% 10000 VA NEXT 37917 VA @ 40% 14367 VA Total 24367 VA A/C LOAD @ 100% 14100 38467 VA 38467/ 240 = 160.28 AMPS 0.I-k7�>�L1 DRAWN 6-30-18 AJL ELECTRIC INC. EC 13002089 12555 BISCAYNE BLVD. #826 N MIAMI, FL 33181 PROPERTY: 1284 NE 94TM STREET SIGNATURE: NOTARY: ,1� MY COMMISSION # Ff 199225 __ �i,.. ,all EXPIRES: February 12, 2019 SHEET 1 OF 1 a.�