Loading...
DGT-12-19-2991, 1234 NE 94 StMiami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Parcel Number 1234 NE 94 ST, Miami Shores, FL 1132050100210 Contacts MARIA GABRIELA CONTRERAS Owner ELI BRAVO Owner 1200 NE 97 ST, MIAMI SHORES, FL 33138 1200 NE 97 ST, MIAMI SHORES, FL 33138 Other:3059492371 Other:3054942371 MARIA GABRIELA CONTRERAS Applicant NAVICON CONSTRUCTION Contractor 1200 NE 97 ST, MIAMI SHORES, FL 33138 ANTONIO JOSE TORRES BETANCOURT Other: 3059492371 175 SW 7 ST 1618, MIAMI, FL 33130 Home: 7862020237 Description: 2 PERGOLAS 141 Valuation, $ 25,000.00 Inspection Requests: Total Sq Feet: 1,500.00 E Fees Amount Application Fee - Other $50.00 CCF $15.00 DBPR Fee $20.25 DCA Fee $13.50 Education Surcharge $5.00 Gazebos, Trellises and Pergolas Fee $550.00 Planning and Zoning Review Fee $35.00 Scanning Fee $9.00 Structural Review ($90) $90.00 Technology Fee $33.75 Total $821.50 Building Department Copy Payments Date Paid Amt Paid Total Fees $821.50 Check# 10102 01/07/2020 $821.50 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Sjgnature: C'wIler / Applicant / Contractor / Agent Date January 07, 2020 Page 2 of 2 RECEIVED Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 D E 2 3 2019 BY: FBC 20 (9-- BUILDING Master Permit No. RC-12 13 -9 � PERMIT APPLICATION Sub Permit No.�-' i L-- c! ) ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 1, (Ar, Cl U S+ City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: I� — 2) 23 -el -0 k � 211(.) Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): aY� G ( 'T� G CJ !A 1'ne r� S Phone#: Address: CO S-r City: waom (��)OT*A State: ��� Zip: ?)51 Jo Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: 0"\a�x %cup Cfd nS 1Y'j C�'*rn Phone#: Address: ,�5 \1.'� 1� S�- 1(0l� o � 2 City: State: Zip: (J Qualifier Name: AiO T(J CY Phone#: State Certification or Registration #: C C C Certificate of Competency #: DESIGNER: Architect/Engineer: Ad City: Phone#: Value of Work for this Permit: Q Q Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace Description of Work: ate: Zip: ❑ Demolition Specify color of color thru.6le: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Technology Fee $ Structural Reviews $ Radon Fee $ Training/Education Fee $ DBPR $ Notary $ Double Fee $ _ Bond $ TOTAL FEE NOW DUE $ _ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Z' �'�Signature OWNER or AGENT C R The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this p 2-&:4^ day of DQ, C.Q V" r" , 20 1 C! by 2� day of I �i�� (/V���� 20 1`1 by C.,Atft( � , who is personally known to U)Nno -Wf'J,-S who is p y kn— to me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign:' Print: Vi Print: s'<; .?' • ` ANALLICIATILLIT MY COMMISSION N GG 345033 MY COMMISSION # GG 345033 Seal: ;off: EXPIRES: � 23, 2023 Seal: '; EXPIRES: Apro 23, 2023 ;a<; o: i �' Bonded Ttuu Nolety Pubic lfiderrnilars , Bonded TMu Notary Public Underwriters io T 1�/3/ 11 f Zoning APPROVED BY � Plans Examiner 11c Structural Review Clerk (Revised02/24/2014) LEAF ENGINEERING 1234 NE 94' Street Miami Shores, FL STRUCTURAL CALCULATIONS FOR PERGOLA Meditation Room/Office Pergola — Page 1— 2 Pool Lounge Pergola — Page 2 Reports 1— 3 LEANDRO FERNANDEZ, P.E. FL PE# 71519 LEAF ENGINEERING CA# 29777 December 18, 2019 •�� No.71519 '`• STATE OF .� >C�� •` � .0 C+ 1®�� ' •?tea /1111110 LEAF ENGINEERING 756 NE 79`" Street, Miami, FL 33138 786.390.7493 - LeafCcDLeafEngineering. net a . . ...... ... 0 • . 0 0 0 0 . STRUCTURAL CALCULATIONS: -Design in accordance with FBC 2017, ACI 318, ASCE 7-10, current editions and addendums, and AISC IVo .* ition. Aluminum to be 6061-T6 welded, Fa, = 24 ksi, Fy =15 ksi, Fcy = 15 ksi • • •. WIND LOAD CALCULATIONS: -Designed following ASCE 7-10, chapter 29, using Table 29.1-1, LOW-RISE BLlILDf Q� ,, Wind load to determine the loading on the pergola. • • • -Step 1: -Risk Category II -Step 2: -Basic wind speed, V=175 mph Step 3: Kd=0.85 -Exposure Category = C -Topographic Factor, Kzt=1.0 -G=0.85 Step 4: -Kz @ 10' = 0.85 Step 5:-qh=0.00256 . Kz . Kzt . Kd . Vz = 56.6 psf c = 0.7 Cf = 1.6 F=qh. G. Cf=56.6x.85x1.6=77.Opsf 77.0 psf x 0.6 = 46.2 psf Live Load = 20.0 psf Dead Load = 20.0 psf Wind Load = 46.2 psf => Actual Wind Load = 0.7 x 46.2 = 32.3 psf Factored loads: 1. 1.4D = 28 psf 2. 1.2D + 1.6L + 0.5(Lr or S or R) = 56.0 psf 3. 1.2D + 1.6(L, or S or R) + (L or 0.5 W) = 24.0 psf 4. 1.2D + LOW + L + 0.5(Lr or S or R) = 76.3 psf 5. 1.2D+ 1.0E+L+0.2S=24psf 6. 0.9D + LOW = 50.3 psf 7. 0.9D + LOE = 18 psf Footings Tributary area per footing =13.5' x 3.2' x 76.3 psf = 3,296# assumed soil capacity of 2,000 psf +. 3,296# / 2,000 psf =1.65 sq. ft. Footing to be 3' x 3' x 12" Footing loading 9 cu ft x 150 pcu=1,350# Total loading is 3,296# + 1,350# = 4,646# Pressure on soil = 4,646# / 9 sq. ft. = 516 psf < 2,000 psf Uplift pressure= 0.9D - W = -14.3 psf Uplift = 13.5'x 3.2'x 14.3 psf = 618# < 1,350# •• • <= use 76.3 psf Page 1/2 .... ...... •..••. .. •..• Footing is adequate for gravity load. Footing is adequate for uplift Connection of base plate to footing with (4)1/2" x 5" effective embedment anchor bolts by Hilt or similar for an ultimate capacity of 4,735# each. (see report 1) Steel strength, bolt capacity = 8,665# (see report 2) Bolt spacing = 7", Load adjustment factor = 0.86 (see report 3) Allowable connection capacity = 0.25 x 4,735# x 0.86 x 4 bolts = 4,072# > 618# Connection is adequate for uplift & gravity Base plate to footing conneciton OK LEAF ENGINEERING 756 NE 7911 Street, Miami, FL 33138 786.390.7493 - Leaf LeafEngineering.net Page 212 Base plate to pipe column connection and pipe column to top plate =1/8" fillet weld all around. Circumference of pipe = 6" x 3.14 =18.8" Capacity of 1 /8" grove weld = 0.64 kfin using 18.8" x 0.64 kip/in =12.03 kips > 0.618 kips Weld connection are adequate. Connection of top plate to pergola is 1 /8" grove weld all around for a total of 8" + 8" + 2" + T = 20" • • ; • • • Capacity of connection is 20" x 0.64 kip/in =12.8 kips > 618" Weld connection is adequate • • •; • • • • Columns, footings and connections are adequate. ; • 0 • • Connection of member 4 to concrete tie beam: .' Loading is 76.3 psf x 3.2' = 244 plf to be resisted by 1 /Z' dia anchor bolts embeded min 3.25" by hilt of s V "1ila *fora shear • • capacity of 12,450# (see report 1) or 12,450 plf > 244 plf Bolt connection is adequate ; • Cantilever beams on each side of the building: • Tributary area is 4.9' • Loading is 4.9' x 76.3 psf = 374 plf M=374 Of x 4.1 1 A 2 / 2 = 3,143 lb-ft Sx of 2x6xl/4 = 2.45 inA3 fb = 3,143 lb-ft x 12 / 2.45 in^3=15,396 psi < 24 ksi Beam is adequate. Shear connection at Connection 'C' Loading on one side is 374 plf / 2 =187 plf Sheara capacity of 2" x 0.25" plate is 15 ksi x 2" x 0.25" = 7.5 kips 187 Of x 2.1' = 393# to be resisted by angle an plate. Plate alone is capable of resisting this small load. Connection is adequate. Connection of members7to concrete be beam: M = 3,143 lb-ft assume that is to be resisted by at least 3 bolts. 3,143 lb-ft x 12 in/ft = 3 x 3" x P P = 4,190 # each bolt Bolt capacity = 4,735# > 4,190# Meditation room/office pergola is adequate. Bolt connection member 2 to be beam is adequate Since the meditation room/office pergola is adequate, the pool lounge pergola is adequate. Pool lounge pergola has smaller spans and loads while have the same size members and connections. Pool lounge pergola is adequate If you have any question or comments, please do not hesitate to contact me at leafCaa leafengineering.net or call me at 786.390.7493 Sincerely, LEANDRO FERNANDEZ, PE FL PE# 71519 LEAF ENGINEERING CA# 29777 E IV NO. 71519 _7� STATE Q � F ka !0'O 1 i 11 !, 0````e LEAF ENGINEERING 756 NE 79` h Street, Miami, FL 33138 786.390.7493 - Leafaa LeafEngineering.net "rvr,,--k -w- I Anchor Fastening Technical Guide, Edition 19 Table 15 - Hilt! KWIK Bolt TZ stainless steel design strength with concrete / pullout failure in uncracked concrete'A3'4.5 Nominal Tension - (pk Shear - 4)V� • anchor Effective Nominal diameter embed. embed. f'� = 2,500 psi f'� = 3,000 psi f'� = 4,000 psi f'= 6,000 psi f'a = 2,500 psi f'� = 3,00;,W 1Py= 4,000 psi f ` = 6,000 psi in. in. (mm) In. (mm) lb (W) lb (kf`i) lb W lb (W) lb (M) lb (kN lb (kt • db (M) 2 2-5/16 1,710 1,875 2,160 2,650 2,375 2,60% • . • • 3,005 . 3,680, 3/8 • 4 (51) (59) (7.6) (8.3) (9.6) (11.8) (10.6) (11.64 • • % (13.4): • -.(16.4): 2 2-3/8 1,865 2,045 2,360 2,890 2,375 2,605 3,005 �• 3,680 (51) (60) (8.3) (9.1) (10.5) (12.9) (10.6) (11.4 • • • • (13.4)' • , ; (16.4) 1/2 3-1/4 3-5/8 3,745 4,100 4,736 5,800 9,845 10,7Er 12,450 15,250 (83) (91) (16.7) (18.2) (21.1) (25.8) (43.8) (48.0 • (55.4; • • : • (67.8) 3-1/8 3-9/16 4,310 4,720 5.450 6,675 9,280 10,16%• ; 11,74Q • 14,380: • • (79) (91) (19.2) (21.0) (24.2) (29.7) (41.3) (45.2) (52.2) • • (64.0) 5/8 4 4-7/16 6,240 6,835 7,895 9,665 13,440 14,725 17,000 20,820 (102) (113) (27.8) (30.4) (35.1) (43.0) (59.8) (65.5) (75.6) (92.6) 3-3/4 4-5/16 5,665 6,205 7,165 8,775 12,200 13.365 16,430 18,900 (95) (110) (25.2) (27.6) (31.9) (39.0) (54.3) (59.5) (68.6) (84.1) 3/4 4-3/4 5-9/16 7,825 8,575 9,900 12,125 17,390 19,050 22,000 26,945 (121) (142) (34.8) (38.1) (44.0) (53.9) (77.4) (84.7) (97.9) (119.9) Table 16 - HIM KWIK Bolt TZ stainless steel design strength with concrete / pullout failure In cracked concretel,2A4.6 Nominal Tension - cpN Shear - qtV� anchor Effective Nominal diameter embed. embed. f'� = 2,500 psi f'� = 3,000 psi f' = 4,000 psi f'c ` 6,000 psi f' = 2,500 psi f'� = 3,000 psi f'a a 4.000 psi f'� = 6,000 psi In. in. (mm) in. (mm) lb (kN) lb (M) lb (kM lb (kN) lb (M) lb (kN) lb (M) lb (kM 2 2-5/16 1,520 1,665 1,925 2,355 1,685 1,845 2,130 2,605 3/8 (51j (59) (6.8) (7.4) (8.6) (10.5) (7.5) (8.2) (9.5) (11.6) 2 2-3/8 1,750 1,915 2,210 2,710 2,375 2,605 3,005 3,680 (51) (60) (7.8) (8.5) (9.8) (12.1) (10.6) (11.6) (13.4) (16.4) 1/2 3-1/4 3-5/8 3,235 3,545 4,095 5,015 6,970 7,640 8,820 10,800 (83) (91) (14.4) (15.8) (18.2) (22.3) (31.0) (34.0) (39.2) (48.0) 3-1/8 3-9/16 3,050 3,345 3,860 4,730 6,575 7,200 8,315 10,185 (79) (91) (13.6) (14.9) 07.2) (21.0) (29.2) (32.0) (37.0) (45.3) 5/8 4 4-7/16 3,795 4,160 4,800 5,880 9,520 10,430 12,040 14,750 (102) (113) (16.9) (18.5) (21.4) (26.2) (42.3) (46.4) (53.6) (65.6) 3-3/4 4-5/16 5,270 5,775 6,670 8,165 12,200 13,365 15,430 18,900 (95) (110) (23.4) (25.7) (29.7) (36.3) (54.3) (59.5) (68.6) (84.1) 3/4 4-3/4 5-9/16 5,720 6,265 7,235 8,860 12,320 13,495 15,585 19,085 (121) (142) (25.4) (27.9) (32.2) (39.4) (54.8) (60.0) (69.3) (84.9) See section 3.1.8 to convert design strength value to ASD value. Linear Interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 19 to 26 as necessary. Compare to the steel values in table 17. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by k as follows: for sand -lightweight, A. = 0.68; for all -lightweight, A = 0.60 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/2-in diameter by 2-in effective embedment depth - a,,,, = 0.64 All other sizes - a = 0.75 No reduction needed for seismic shear. See Section 3.1.8 for additional information on seismic applications. Anchor Fastening Technical Guide Edition 19 13.0 ANCHORING SYSTEMS 1 3.3.5 KWIK BOLT TZ EXPANSION ANCHOR 295 Hilti, Inc. (U.S.) 1-800.879-80001 en espahoi 1-800-879-5000 1 www.hilti.com I Hilti (Canada) Corporation I www.hilti.com 1 1-800.363-4458 Table 17 - Steel strength for Hilts KWIK Bolt TZ stainless steel anchors'-z Nominal anchor diameter Tensile 4)N„3 Shear 4)V _4 Seismic shearioV.,,a in. lb (kN) lb (kN) lb (W) 4,475 3,070 1,835 3/8 (19.9) (13.7) (8.2) 8,665 4,470 4,470 1/2 (38.5) (19.9) (19.9) 13,410 6,415 6,080 5/8 (59.7) (28.5) (27.0) 18,040 10,210 8,380 3/4 (80.2) (45.4) (37.3) 1 See section 3.1.8 to convert design strength value to ASO value. 2 Hilti KWIK Bolt TZ stainless steel anchors are to be considered ductile steel elements. 3 Tensile (PN,,, = (p A,, N flIN as noted in ACI 318-14 Chapter 17. 4 Shear values determined by static shear tests with ()V,, < (p 0.60 A,,,,, f�,., as noted in ACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with (PV,,, ,,,t < N 0.60 Az„v f,,, as noted in ACI 318-14 Chapter 17. See section 3.1.8 for additional information on seismic applications. Figure 3 Anchors not permitted in shaded area Case 2 ( i Case 1 Concrete Edge •••••• • • •• •••••• •••••• •••••• • • ••••• • • • • • •••••• For a specific edge distance, the permitted spacing is calculated as follows: (smn.i — SN S s o + min : (C — C ) C ,� I at S mint min... a rn at Table 18 - Stainless steel Hilts KWIK Bolt TZ installation parameters' C4, -, edge distance c Setting Nominal anchor diameter d 3/8 1/2 5/8 3/4 information Symbol Units Effective minimum h in. 2 2 3-1/4 3-1/8 4 3-3/4 4-3/4 embedment' ' (mm) (51) (51) (83 (79) (102) 95) (121) Min. member thickness h.. in. 4 5 4 6 1 6 8 5 6 8 6 8 8 (mm) (102) (127) (102) (152) (152) (203) (127) (152) (203) (152) (203) (203) in. 2-1/2 2-7/8 2-1/8 3-1/4 2-3/8 4-1/4 4 (mm) (64) (73) (54) (83) 1 (60) (108) (102) Case 1 for in. 5 5-3/4 5-1/4 5-1/2 5-1/2 10 8-1/2 s Z (mm) (127) (146) (133) (140) (140) (254) (216) in. 3-1/2 4-1/2 3-1/4 4.1/8 4-1/4 9-1/2 7 (mm) (89) (114) (83) (105) (108) (241) (178) Case 2 for in. 2-1/4 2-7/8 2 2-3/4 2-3/8 5 4 s , a((mm) (57) (73) (51) 1 (70) 1 (60) (127) (102) 1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2. Linear interpolation for a specific edge distance c, where c.n,n , < c < c„ ,, will determine the permissible spacings. 296 Anchor Fastening Technical Guide Edition 19 13.0 ANCHORING SYSTEMS 1 3.3.5 KWIK BOLT TZ EXPANSION ANCHOR Hilti, Inc. (U.S.) 1-800-879-80001 en espahol 1-800-879-5000 1 www.hilti.com I Hilti (Canada) Corporation I www.hiiti.com 1 1-800-363-4458 Table 21 - Load adjustment factors for 1/2-In. diameter stainless steel Hilts KWIK Bolt TZ In uncracked concrete',2 1/2-in. KB-TZ SS uncracked concrete Spacing factor in tension f,. Edge distance factor in tension f. Spacing factor in shear' f�� Edge distance In shear Conc. fac- tocsin shear' ? 4G . A. toward edge fr, , It to and away from ecige • f„„ • • Effective in. embed. ha (mm) 2 (51) 3-1/4 (83) 2 (51) 3-1/4 (83) 2 (51) 3-1/4 (83) 2 1 (51) 3-1/4 (83) 2 (51) •4391► • •0(8*•• 2• (51) • 4.1/4 • (83) Nominal in. embed. h (mm) 2-3/8 (60) 3-5/8 (92) 2-3/8 t�l 3.5/8 (92) 2-3/8 (�) 3-5/8 (` 2.3/8 (�) 3-5/8 (9� 2-3/8 (�) •�• • (9 2.3• ( 8-5/8 • • It 2 51 nor 0.60 n/a na n/a 0.54 n/a na n/a ••a •• nor a 2.1 8 (54 n or 0.61 n/a 0.39 n/a 0.54 n/a 0.11 n or n/2 • !t a 2.7 (73) 0.74 1 0.65 0.53 0.45 0.63 0.55 0.53 0.17 0.53 . 5 rVa n/a 3 (76) 0.75 1 0,65 0.55 0.46 0.63 0.55 0.55 0.19 0.55 • • n/a n/a 3-14 83 0.77 1 0.67 0.59 0.49 0.64 0.56 0.59 0.21 0.59 0.42 n • a 3.1 89 0.79 1 0.68 0.64 0.51 0.65 0.56 0.64 0.23 0.64 0. P n/a n/a 8 4 (102) 0.83 1 0.71 0.73 0.56 0.68 0.57 0.73 0.29 0.73 00.56o 0.86 • • a 4.12 (114) 0.88 1 0.73 0.82 0.61 0.70 0.58 0.82 0.34 0.82 0.61 0. a E 5 (127) 0.92 0.76 0.91 0.67 0.72 0.59 0.91 0.40 0.91 0.67 0.94 n/a c 5-1/4 133) 0.94 0.77 0.95 0.70 0.73 0.60 0.95 0,43 0.95 0.70 0.96 n a 5-1/2 140 0.96 0.78 1.00 0.73 0.74 0.60 1.00 0.46 1.00 0.73 0.98 n/a a 6 152) 1.00 0.81 0.80 0.76 0.61 0.53 0.80 1.00 0.66 7 (178) 0.86 0.93 0.81 0.63 0.66 0.93 0.71 g 8 (203) 0.91 1.00 0.85 0.64 0.81 1.00 0.76 9 229) 0.96 0.89 0.66 0.97 0.81 10 (254 1.00 0.94 0.68 1.00 0.85 is 11 279 0.98 0.70 0.89 12 305) 1.00 0.72 0.93 14 356) 0.75 1 1.00 16 406) 0.79 18 457) 0.93 > 20 508 0,86 Table 22 - Load adjustment factors for 1/2-in. diameter stainless steel Hilts KWIK Bolt TZ in cracked concrete" 1/2-in. KB-TZ SS cracked concrete Spacing factor in tension f0.N Edge distance factor in tension ffW Spacing factor in shear' fl, Edge distance in shear Conc. thickness fac- tor in shear4 fW 1 toward edge fury tl to and away from edge fpv Effective in. embed. h. (mm) 2 (51) 3-1/4 (83) 2 (51) 3-1/4 (83) 2 (51) 3-1/4 (83) 2 (51) 3-1/4 (83) 2 (51) 3-1/4 (83) 2 (51) 3-1/4 (83) Nominal In. embed. him (-) 2-3/8 (60) 3-5/8 (92) 2-3/8 (60) 3-5/8 (92) 2-3/8 (60) 3-5/8 (92) 2-3/8 (60) 3-5/8 (92) 2-3/8 (60) 3-5/8 (92) 2-3/8 (60) 3.5/8 (92) 2 (51) n/a 0.60 n/a n/a n/a 0.54 n/a n/a n/a n/a n/a n/a 2-1 (54) n/a 0.61 n/a 0.60 n/a 0.54 n/a 0.11 n/a 0.22 n/a n/a 2.7/8 (73) 0.74 0.65 0.97 0.70 0.60 0.55 0.47 0.18 0.94 0.35 n/a n/a 3 (76) 0.75 0.65 1.00 0.71 0.60 0.55 0.50 0.19 1.00 0.38 n/a n/a 3.1 4 83 0.77 0.67 1.00 0.75 0.61 0.56 0.56 0.21 1.00 0.42 n/a n/a 3-1 89 0.79 0.68 1.00 0.79 0.62 0.56 0.63 0.24 1.00 0.47 n/a n/a u 4 (102 0.83 0.71 1.00 0.86 0.64 0.57 0.77 0.29 1.00 0.58 0,75 n a E 4-1/2 114) 0.88 0.73 1.00 0.94 0.66 0.56 0.92 0.34 1.00 0.69 0.79 n/a E 5 127) 0.92 0.76 1.00 0.67 0.59 1.00 0.40 0.81 0.84 n a c 5.1 4 (133) 0.94 0.77 0.68 0.60 0.43 0.87 0.86 n/a 5-1 140 0.96 1 0.78 1 0.69 1 0.60 0.47 0.93 0.88 n/a v yG-� 6 152 1.00 0.81 0.71 0.61 0.53 1.00 0.92 0.66 C 7 (178) 0.86 0.74 0.63 0.67 0.99 0.71 g 8 203 0.91 0.78 0.65 0.82 1.00 0.76 ZO:w 9 (229) 0.96 0.81 0.66 0.98 1 1 0.81 10 (254) 1.00 0.85 0.68 1.00 0.85 11 279 0.88 0.70 0.90 12 305 0.92 1 0.72 1 0.94 14 (356) 0.99 0.76 1.00 16 406 1.00 1 0.79 18 (45 0.83 > 20 508 0.86 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hiltl PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, f, , assumes an influence of a nearby edge. If no edge exists, then f w - f,. 4 Concrete thickness reduction factor in shear, f ,, assumes an influence of a nearby edge. If no edge exists, then f = 1.0. C_7 If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 17 and figure 3 of this section to calculate permissabie edge distance, spacing and concrete thickness combinations. 298 Anchor Fastening Technical Guide Edition 1913.0 ANCHORING SYSTEMS 1 3.3.5 KWIK BOLT TZ EXPANSION ANCHOR Hilti, Inc. (U.S.) 1-800-879-8000 1 en espa?iol 1-800-879-5000 1 www.hilti.com I Hilti (Canada) Corporation I www.hilti.com 1 1-800-363-4458