Loading...
RC-10-19-2368, 29 NE 102nd St (3)Miami Shores Village ImDT's.'7717"',-­71 7a I Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC ZO q Q BUILDING Master Permit No. PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION 2 SHOP / CONTRACTOR DRAWINGS S JOB ADDRESS: �� / A City: Miami Shores County: Miami Dade Zip: 33 Folio/Parcel#: 0%1Z anI Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): ��tN �� s� Phone#:6- JI 16y- Address: c��0+ 2 '�; t City: State: Zip: Tenant/Lessee Name: Phone#: Email: CON' Addr City: yr v1 a tit - Qualifier Name: �^ State Certification or Registration #: C �� DESIGNER: Architect/Engineer: Certificate of Competency #: Address: City: State: Value of Work for this Permit: $ Jai.% Square/Linear Footage of work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace Description of Work:,} Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $_ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Structural Reviews $ _ Zip: ❑ Demolition CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ 4�® (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulatin construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement mys7 be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the g�b�en e such posted notice, the inspection will not be approved and a reinspection fee will be charged. / Signature / ' Signatu �i(lUiLi OWNER or AGENT (The foregoing instrument was lacknowledged before me this J -i� ® day of OA [) IrQ , 20 I by ® 400lradcl , who is p sonally kno to �— me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: The foregoinAi0strument was acknowledged before me this day of ►r l' .20 by Lid 'L e wh a onally k n to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: as Seal: ��r rug Seal: ... �'r MATTHEW LAND �►R��op�� * Commission GG 915126 y EWL4N0 '"F F v o, 7 Expires October 12, 2023 \or E # GG 915126 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) ENTERED OCT 2 5 ZO21 // arl- A"' r%%jr"SS COMPANY, INC. Trusses & Building Materials 13980 SW 252 Street, Miami, Florida 33032 Telephone: (305) 257-1910 Fax: (305) 257-1911 www.decotruss.com : • • •:. WARNI NG: •••�•• •••• Extreme Care is required in Handling, Erecting and Bracing Trusses 0Refer to • TPI's "HIB-91 Summary Sheet", which is attached, to the engineering* pack�gb.• BUILDING DESIGNER (ARCHITECT or ENGINEER of Recorded) • • • • • • • It is your responsibility to determine that the dimensions conform to the architectural plans a:id all laads uwiized. herein meet or exceed the actual Dead Loads Specified and /or imposed on your structure, arod Live lad6•• imposed by The Building Code. PERMANENT BRACING shall be designed and specified by theabuildtng destgjVr; for the structural safety of the building. It shall be the responsibility of the building designer to indicate'size, location and attachments for all permanent bracing as required by design analysis. The design and location of all bracing shall be such that they work together with other structural parts of the building (such as shear walls, portal frames, bearing walls, columns, beams etc.) to achieve total structural integrity Permanent Bracing includes and is not limited to The Top Chord Plane, The Bottom Chord Plane and The Web Member Planes. The Anchoring / Strapping of trusses to walls, beams, ledgers etc., shall be the responsibility of The Building Designer. Truss to Truss Connections shall be The Responsibility of The Truss Manufacture. (Refer to Documents ANSI/TPI- 95 & WTCA-95 for further information) TRUSS ERECTOR / INSTALLER (Builder) The proper and safe erection of all the trusses is exclusively your responsibility. You are cautioned to seek professional advice regarding the Erection / Installation and Bracing, which is ALWAYS required to prevent toppling and dominoing. Top Chord, Bottom Chord and Webs shall be adequately braced, as per the attached HIB-91 Summary Sheet. You are also responsible to refer to the Truss Placement Plan and The Engineering when erecting Trusses, to insure proper placement. Not all trusses are symmetrical in loading and/or design. Proper Placement and/or direction are always required. Check all Flat Truss to insure they are not installed UPSIDE DOWN. Never cut or alter trusses in anyway. Never concentrate Building Materials, such as Plywood or Blocks on installed Trusses. Alterations to Trusses: "The act of cutting or attaching any item that the truss was not originally designed for" Trusses cannot be altered from the attached engineering designs, with out proper re -designing by a Florida Registered Engineer. We highly recommend to our customers to use our engineer, however to our knowledge there is no code that states you must use the engineer, who sealed the truss engineering and layout. However, it is of the utmost importance that, any Florida Registered Engineer who takes the task of designing repairs to trusses, should be extremely knowledgeable, not only in structural designs but also have experience designing trusses. Should any alterations be made to our design or manufactured item, the engineer, contractor and homeowner waive all warranties and liabilities by Deco Truss Company, Inc., its officers and engineer. All future, questions regarding said structure and warranties will be held by the persons whom redesigned said trusses and altered them. ALWAYS REFER TO THE ATTACHED HIB-91 Summary Sheet f . Deco Truss Company, Inc. EGO 13980 SW 252nd ST TRUSS COMPANY, INC. Miami, FL 33032 Trusses & Building Materials Tel: (305) 257-1910 Fax: (305) 257-1911 Re: 12728: ULVERT -ANDRADE Site Information: Project Customer DTORR Job Name ULVERT - ANDRADE RESIDENCE Lot/Block: Subdivision : Site Name: Site Address: 21 NE 102nd ST. •••••• MIAMI SHORES St: FL. Zip: : General Truss Engineering Criteria & Design Loads (Individual Truss Design,Drawings &how Special Loading Conditions): •' •"' : • • • •: Design Code: FRC2017/TP12014 Design Program: 8.43 Jun 17 2021 Roof Load: 55.0psf• Fl$$.•Load:; • .: • N/,4. • • 9 • Wind Code: Wind Speed: 175 mph •••••• • ••• ••••• 066090 • • • • This package includes 5 individual, dated Truss Design Drawings and 0 Additionel•Drawings? •, With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer dhd thVOdex shddf conforms to 61G15-31.003, section 5 of the Florida Board of Professional Enginee$s Rl!ies. •• No. Date Truss ID# Seal# 1 10/06/21 Al A0091246 2 10/06/21 A2 A0091247 3 10/06/21 A3 A0091248 4 10/06/21 A4 A0091249 5 10/06/21 A5 A0091250 ®EXCe�.i TAKEN Q r )'DP OVED /RpEVIS�kxpA�rypNCD Cv4/.ionS uur coi,i ,}t� ,Ids, r'n' ji!i5 SI!C)p drawr4gs dUdrag i3,i^ ; -ekeve con- trarcSor frox,t ccmnj,.+ ;• ,,.si:. menu of the permitted Jrawi This check is only for reviswv c4 ,-rm@nce with the de*##n wicer 4e., and E;etle(al compliance with r - n in 11re contract �.Xurr f , r=.porsib e for; cc-liirming arr: :,,=: ;s',:ir, : ano dimensions; seliecti� . o , 1r10, techniques of her work with that of ak :! 3er r.=,, ec and perfrorming his at ur'k in a cv 5 ui;:', manner.. X e E qqppee^+ ft N[ tt f 66 K co'su tirkg �1,ng'soovc ,, '3wr J The seal on this index sheet indicates acceptance of professional engineerin r onsi�� solely for the truss design drawings listed above and attached. ' `" '°'`4.4"• Truss Design Engineers Name: Mahmound Zolfaghari P.E. n License Number #: 36921 Address: 13901 SW 108 Ave, Miami, FL 331 a w • u. i • %D STATE OF `•s NOTE: The suitability and use of each component for any particular buiI ing is the � R , "� responsibility of the Building Designer, perANSI/TPI 1-1995 Section 2. ",Pprl) Page 1 of 1 Engineers Name Date Job Truss Truss Type[ly ULVERT- ANDRADERES. (RC) 12728 Al Roof Special 4 1 Job Reference (optional) utw i rcuaa wiwrHv4r n6., rnnceeun, rc oow< Run. o.Vou a —1 i a dun i cue i iv eu vu o 1". . — <u< i reye , ID:XRXRCHyzQsw4r10FJvBUE5zPEEF-UQk211R5U?TlrIV3v5EOFxs?Fm_cKJlyGxt JpyW75W 8-10-14 17-9-13 26 8 11 32-9-5 42-1-0 44 9-8 8-10 14 8-10-14 8910-14 6-0 11 9-3-11 7x8 2 4x10 = 20 1 1 4x8 = 44 = 4 3 �. T 5.00 F12 5x6 = 2.50 F12 6 5x6 26 5 Scale = 1:80.9 27 5x8 MT18HS' 28 • ••• 23 8 •••••• • • • ••• •• •••• • • • • • Ve 24 3112 • 37 • o 5x811 •••••• • • • 4x6 — 29 193021 31 32 15 33 —•00000 12 34 40035 • 00 16 t4 17 13 17 1I I • • • • • 10x10 11 2x4 11 5x10 MT20HS= 4x4 = 5x8 = • • : • • • • 2„y 1010 •• •• •• • •••••• 4x6 = 5x8 = • • • •• • •••••• • • • •• • • 2-4-0 • • • • • 44-9-8 • • i 2-0-0 8-10-14 17-9-13 i 26-8-11 i 32-9-5 i 42-1-0 •• •4�_�Jrs i 2-0-0 6-6-14 8-10-14 B-10-14 6-0-11 9-3-11 8- 2-0-0 LOADING (psf) TCLL 30.0 TCDL 15.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.33 Lumber DOL 1.33 Rep Stress Incr YES Code FRC2017/TP12014 CSI. TC 0.83 BC 0.64 WB 0.92 Matrix-MSH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl L/d 0.61 14-16 >819 360 -0.82 14-16 >615 240 0.05 9 n/a n/a PLATES MT20 MT20HS MT18HS Weight: 305 lb GRIP 244/190 187/143 244/190 FT = 0% LUMBER- BRACING - TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x6 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 4-3-11 oc bracing. B1: 2x6 SP M 26, B4: 2x4 SP No.2, 132: 2x6 SP No.1 D WEBS 1 Row at midpt 2-14, 3-13, 5-11, 7-11 WEBS 2x4 SP No.2 *Except* W9: 2x6 SP No.2 WEDGE Left: 2x4 SP No.2, Right: 2x4 SP M 31 REACTIONS. (lb/size) 1=2411/0-8-0 (min. 0-2-0), 9=2516/0-8-0 (min. 0-3-0) Max Horz 1=450(LC 9) Max Uplift1=-1375(LC 9), 9=-1136(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 18-20=-2328/1324, 20-25=-6352/3561, 2-25=-6332/3571, 2-3=-5908/3299, 3-4=-3856/2102, 4-5=-3763/2119, 5-26=-2166/1247, 6-26=-2064/1264, 6-27=-2066/1240, 27-28=-2083/1222, 7-28=-2250/1207, 7-23=-330/551, 8-23=-139/306 BOT CHORD 19-30=-1672/2353, 21-30=-1672/2353, 21-31=-3816/6137, 16-31=-3816/6137, 16-32=-3831/6149, 15-32=-3831/6149, 14-15=-3831/6149, 14-33=-3442/5738, 13-33=-3442/5738, 12-13=-2094/3658, 12-34=-2094/3658, 11-34=-2094/3658, 9-10=0/280, 7-9=-2475/1650, 9-36=-453/276, 24-36=-453/276, 24-37=-267/144, 22-37=-267/144 WEBS 2-14=-495/416, 3-14=-42/452, 3-13=-2243/1464, 5-13=-503/996, 5-11=-2388/1545, 6-11=-534/1024, 7-11=-1040/2065, 2-16=-234/289, 18-19=-1291/783, 19-20=-2436/1315, 18-21=-1251 /2165 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=175mph (3-second gust) Vasd=136mph; HVHZ; TCDL=5.Opsf; BCDL=5.Opsf; h=16ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) 0-0-0 to 4-5-12, Interior(1) 4-5-12 to 28-3-9, Exterior(2) 28-3-9 to 37-3-2, Interior(1) 37-3-2 to 40-3-12, Exterior(2) 40-3-12 to 44-9-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5 Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1375 lb uplift atjoint 1 and 1136 lb upliftat joint 9. r; 6) This truss has been designed for a moving concentrated load of 200.0Ib dead located at all mid panels and at all panel points alo the Bottom Chord, nonconcurrent with any other live loads. r; F! < . LOAD CASE(S) Standard a � o • } e 4 s' e STATE OF .a a4 A, ® ! M�ca40 Job Truss Truss I ype ty y ULVERT- ANDRADERES, (RC) 12728 A2 Roof Special 4 1 Job Reference (optional) vow ,n QQVVrv"n,'� uv , wiw� ,-�.�ovac 1� III V'E"E" II GVGI VII'anIIWU"'4"G' R1G. WB9?U2 Ol41La:DVLUL" rage i I D:XRXR C HyzOsw4r1 OFJv6 U ESzP EE F-ycl OF5SjFJ b95S4GSpldo809?AKr3 mYSVbdXsGyVVISV 810-14 17-9-13 26-8-11 32-9-5 42-1-0 449-8 8-10-14 8 10 14 8-10.14 6-0 11 9-3-11 2-8-8 7x8 2 4x10 = 20 25 124 1 18 0 29 193021 31 16 17 10x10 II 2x4 11 .1 14 5x10 MT20HS= 4x6 = 5.00 12 5x6 = 2.50 Ff2 6 13 " 44 = 5x8 = Scale = 1:80.9 5x8 MT18HS� 028 • • • @70 23 006000 r • •.M . 1 b • 37 • o •••••• M •• • • • •• 4x6=00000 • i0.410 11 ••••• • • •••••• • • • • •• • •••••• 2-4-0 • • • • • • ••• 4-9-8 • • i 2-0-0 i 8-10-14 17-9-13 1 26-8-11 i 32-9-5 , 42-1-0 4-9r i r 2-0-0 6-6-14 8-10-14 8-10-14 6-0-11 9-3-11 Plate Offsets (X Y)-- [1:0-6-13 0-0-7] [2:0-4-0 0-4-8], [5:0-3-0,0-2-12], [7:0-1-0,0-2-4], [8:0-0-12 1-4-3] [8:0-3-5,0-0-101 [9:0-4-4 0-2-12] [1 0:0-2-0 0-0-8] [11:0-4-0 0-2-12] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.33 TC 0.83 Vert(LL) -0A4 14-16 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.33 BC 0.64 Vert(CT) -0.82 14-16 >615 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.92 Horz(CT) 0.05 9 n/a n/a MT18HS 244/190 BCDL 10.0 Code FRC2017/TP12014 Matrix-MSH Weight: 305 lb FT = 0% LUMBER - TOP CHORD 2x6 SP No.2 BOT CHORD 2x6 SP N0.2 *Except* B1: 2x6 SP M 26, B4: 2x4 SP No.2, 132: 2x6 SP NoAD WEBS 2x4 SP No.2 *Except* W9: 2x6 SP No.2 WEDGE Left: 2x4 SP No.2, Right: 2x4 SP M 31 REACTIONS. (lb/size) 1=2411/0-8-0 (min. 0-2-0), 9=2516/0-8-0 (min. 0-3-0) Max Horz 1=294(LC 9) Max Upliftl=-830(LC 9), 9=-691(LC 9) BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-11-5 oc bracing. WEBS 1 Row at midpt 2-14, 3-13, 5-11, 7-11 FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 18-20=-2328/1054, 20-25=-6352/2911, 2-25=-6332/2921, 2-3=-5908/2796, 3-4=-3856/1952, 4-5=-3763/1969, 5-26=-2166/1247, 6-26=-2064/1264, 6-27=-2066/1240, 27-28=-2083/1222, 7-28=-2250/1207, 7-23=-330/551, 8-23=-139/306 BOT CHORD 19-30=-1190/2353, 21-30=-119012353, 21-31=-2912/6137, 16-31=-2912/6137, 16-32=-2925/6149, 15-32=-2925/6149, 14-15=-2925/6149, 14-33=-2704/5738, 13-33=-2704/5738, 12-13=-1745/3658, 12-34=-1745/3658, 11-34=-1745/3658, 9-10=01280, 7-9=-2475/1650, 9-36=-453/276, 24-36=-453/276, 24-37=-267/144, 22-37=-267/144 WEBS 2-14=-495/258, 3-14=0/452, 3-13=-2243/1034, 5-13=-332/996, 5-11=-2388/1236, 6-11=-366/1024, 7-11=-944/2065, 18-19=-1291/686, 19-20=-2436/1104, 18-21=-993/2165 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=175mph (3-second gust) Vasd=136mph; HVHZ; TCDL=5.Opsf; BCDL=5.Opsf; h=16ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 4-5-12, Interior(1) 4-5-12 to 28-3-9, Exterior(2) 28-3-9 to 37-3-2, Interior(1) 37-3-2 to 40-3-12, Exterior(2) 40-3-12 to 44-9-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 830 lb uplift at joint 1 and 691 lb uplift at joint 9. 6) This truss has been designed for a moving concentrated load of 200.01b dead located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. e LOAD CASE(S) Standard n 6. Tr Job Truss Truss Type Qty Ply ULVERT- ANDRADERES. (RC) 12728 A3 Roof Special 21 1 Job Reference (optional) UtL,V I KUJJ V VMYANY INU., Ynnceion, FL :54UJZ Kun: bAJU s Jun 1 r LULI Y'nni: b.43U s JUn 1 i LULI MI I eK Inausines, Inc. Wea VC1 b 14:19:b2 2U21 Nage 1 I D:XRXRCHyzQsw4rl O FJvB U E5zP E EF-v? PAg n UzmwrtimEeaEn5tZUTJzzLXf?Oyu6ew8yW75T 8-2-11 16 5-5 24-8-0 26 8-11, 3%- , 42-1-8 44-9-8 8-2-11 8-2-11 8-2-11 2-0-11 6-0-11 9-4-3 2-8-0 1 7x8 = 2 4x10 = 24 26 1 22 0 o 30 233125 32 17 21 10x10 II 2x4 11 __ — 15 5xl0 MT20HS= 5x14 = 5.00 F12 5x6 = 2.50 12 7 14 U4 11 Scale = 1:79.9 • M p • 10 38 20 18 39 • 9 • • 510 II 4x64t= • • •• ••••• • • • • • •••••• • • • • • • 44-9-8 Plate Offsets (X Y)-- [1:0-6-1 3 0-0-7][2:0-4-0,0-4-8],[3:0-3-12,0-2-0], [6:0-5-0,0-4-0],[8:0-5-0,0-3-8],[10:0-4-8,0-2-8], [11:0-5-0,0-4-4], [13:0-6-12,0-2-01, [15:0-3-10-2-12] LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.33 TC 0.97 Vert(LL) -0.96 14 >528 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.33 BC 0.83 Vert(CT) -1.76 14 >288 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(CT) 0.44 10 n/a n/a M18SHS 244/190 BCDL 10.0 Code FRC2017/TP12014 Matrix-MSH Weight: 302 lb FT = 0% LUMBER - TOP CHORD 2x6 SP No.2 *Except* T335: 2x6 SP No. 10 BOT CHORD 2x6 SP No.2 *Except* 61,64: 2x6 SP M 26. B3: 2x4 SP No.2, B2: 2x6 SP No.1D WEBS 2x4 SP No.2 *Except* W5: 2x4 SP M 31, W11: 2x6 SP No.2 WEDGE Left: 2x4 SP N0.2 REACTIONS. (lb/size) 1=2423/0-8-0 (min. 0-2-0), 10=2504/0-8-0 (min. 0-2-15) Max Horz 1=294(LC 9) Max Upliftl=-833(LC 9), 10=-688(LC 9) BRACING - TOP CHORD Structural wood sheathing directly applied or 1-6-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-5-3 oc bracing. WEBS 1 Row at midpt 2-15, 13-15, 3-13, 8-11 2 Rows at 1/3 pts 6-11 FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 22-24=-2318/1056, 24-26=-6261/2881, 2-26=-6241/2890, 2-3=-6209/2927, 3-4=-10551/5163, 4-5=-10455/5177, 5-6=-9861/4924, 6-27=-4783/2442, 7-27=-4718/2459, 7-28=-5388/2726, 28-29=-5410/2709, 8-29=-5586/2693, 8-19=-743/305 BOT CHORD 23-31=-1187/2339, 25-31 =-1 187/2339, 25-32=-2884/6048, 17-32=-2884/6048, 17-33=-2899/6065, 16-33=-2899/6065, 15-16=-2899/6065, 13-14=0/269, 5-13=-108/351, 13-35=-5005/10440, 12-35=-5002/10443, 12-36=-4723/9824, 11-36=-4716/9845, 11-37=-299/355, 10-37=-320/327, 10-38=-387/875, 20-38=-387/875 WEBS 2-17=-298/262, 2-15=-290/159, 3-15=-1996/1118, 13-15=-2980/6301, 3-13=-2071/4200, 5-12=-855/457, 6-12=-186/462, 6-11=-5289/2677, 7-11=-1395/3268, 8-11=-2203/4652, 8-10=-2527/1736, 19-20=-314/194, 22-23=-1302/697, 23-24=-2409/1097, 22-25=-986/2139 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=175mph (3-second gust) Vasd=136mph; HVHZ; TCDL=5.Opsf; BCDL=5.Opsf; h=16ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 4-5-12, Interior(1) 4-5-12 to 28-3-9, Exterior(2) 28-3-9 to 37-3-2, Interior(1) 37-3-2 to 40-3-12, Exterior(2) 40-3-12 to 44-9-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 833 lb uplift at joint 1 and 688 lb uplift joint 10. 6) This truss has been designed for a moving concentrated load of 200.Olb dead located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard a' ,•o°vim r e: `c. • x • e Sr''YE OF II F o- S ; Job rusS Truss Type aty ly 71 ULVERT- ANDRADE RES. (RC) 12728 A4 Roof Special 1 Job Reference (optional) uCI.V i rtuJJ Ii VVIrMIV i IYV Ii., rni lR , IL —W1 —0. 6.40U s Jun 1 / NCI rnnl. 0.43u s Jun -I ( LUL-I MI I eK InousLnes, Inc. vveo Uc[ b 14:zy:0a ZU2l Page l ID:XRXRCHyzQsw4r1 OFJvBUE5zPEEF-rOXx4SVDIY6bx301 hepZy_ZulnkS?cunuL Di?1yW75R 220 0 19-0-0 24 8-0 26 8 11 32-9-5 42-1-8 44 9-8 9-6 0 9-6-0 5 &0 2-0-11 6 0.11 9-4-3 2-8 0 2.50 12 5.00 12 5x6 = 7 Scale = 1:79.5 5x6 5x6 � 27 28 4x8 6 4x4 : 5 • 29 • 6x6 4 3 • ••• • 8 •••:• C 7x8: 36 11 ••cc • 6x8=•••:••37 19 • 9 • o a 2 ••• •••JWi 35 12 4x6 = 2 24 4x 3 4; •••••• • 10 38 20 3Q.••i 22 l l 15x8 • • • • • • 5�8 II 4x6� • 1;9 l 2.50 12 • • • • • 21 30 4x10 II 17 15 34 14 •••••• • ••• ••i••• 233125 32 2x4 11 33 16 6x8= 2x4 II •••••• •••• i •••••• 4x8 = • so • • •• • •••••• • • • • • • 44-9-8 2-0-0 9-6-0 19-0-0 24-8-0 26-8-11 33-4-12 42-1-8 • 4 -9 8 2-0-0 7-6-0 9-6-0 5-8-0 2-0-11 6-8-1 8-8-12 -8- 2-0-0 Plate Offsets (X,Y)-- [1:0-8-1 3 0-0-7] [1:0-0-7 2-8-14] [2:0-4-0,0-4-8], [6:0-3-0,0-2-12], [8:0-2-12,0-3-81,[10:0-4-4,0-2-81, 1`11:0-4-0 0-3-81, [13:0-540-2-0] [15:0-2-12 0-4-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.33 TC 0.69 Vert(LL) -0.07 11-12 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.33 BC 0.54 Vert(CT) -0.19 10-11 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.80 Horz(CT) 0.08 10 n/a n/a BCDL 10.0 Code FRC20171TP12014 Matrix-MSH Weight: 298 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8-2 oc purlins. BOT CHORD 2x6 SP No.2 `Except* BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 133: 2x4 SP No.2 10-0-0 oc bracing: 12-13,11-12. WEBS 2x4 SP No.2 *Except* WEBS 1 Row at midpt 2-15, 13-15 W11: 2x6 SP No.2 WEDGE Left: 2x4 SP No.2 REACTIONS. All bearings 17-4-0 except Qt=length) 10=0-8-0. (lb) - Max Horz 1=294(LC 9) Max Uplift All uplift 100 lb or less at joint(s) except 1=-161(LC 5), 10=-424(LC 10). 17=-265(LC 5), 15=-858(LC 9) Max Grav All reactions 250 lb or less at joint(s) except 1=499(LC 16), 10=1317(LC 1), 17=628(LC 16), 15=2547(LC 1), 1=483(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 22-24=-100/432, 24-26=-212/286, 2-26=-202/376, 2-3=-681/1449, 3-4=-356/235, 4-5=-282/244, 5-6=-11461699, 6-27=-1609/898, 7-27=-1516/915, 7-28=-1626/903, 28-29=-1637/886, 8-29=-1813/870, 8-19=-421/298 BOT CHORD 23-31=-422/60, 25-31=-422/60, 25-32=-292/110, 17-32=-292/110, 17-33=-287/95, 16-33=-287/95, 15-16=-287/95, 5-13=-1031/532, 13-35=-163/298, 12-35=-160/305, 12-36=-540/1187, 11-36=-528/1201, 11-37=-343/293, 10-37=-362/275, 10-38=-306/554, 20-38=-306/554 WEBS 2-17=-416/330, 2-15=-1087/622, 3-15=-1385/810, 13-15=-1526/802, 3-13=-783/1633, 5-12=-527/1051, 6-12=-759/507, 6-11=-34/358, 7-11=-74/554, 8-11=-560/1245, 8-10=-1384/1189, 19-20=-368/260, 22-23=-270/213 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=175mph (3-second gust) Vasd=136mph; HVHZ; TCDL=5.Opsf; BCDL=5.Opsf; h=16ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 4-5-12, Interior(1) 4-5-12 to 28-3-9, Exterior(2) 28-3-9 to 37-3-2, Interior(1) 37-3-2 to 40-3-12, Exterior(2) 40-3-12 to 44-9-8 zone; cantilever left and right exposed ;C-C for members and forces & p MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3 Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 161 lb uplift at joint 1, 424 lb uplift at joii# $'r 10, 265 lb uplift at joint 17, 858 Ib uplift at joint 15 and 161 Ib uplift at joint 1. 5) This truss has been designed for a moving concentrated load of 200.01b dead located at all mid panels and at all panel points alon 'f — the Bottom Chord, nonconcurrent with any other live loads. :+ x LOAD CASE(S) Standard Job Truss Truss Type Qty Ply ULVERT- ANDRADERES. (RC) 12728 A5 Roof Special 4 1 I 7 Job Reference (optional) UCUV IKUJS UUMYANY i"t_ hTU1ceton, VL 3JUJZ s Jun if zuzi Yn7II: t5.4su s Jun if zuzi mt I eK Inausmes, Inc. Wea UCt b 142`J:bb ZNZI rage 1 HyzQsw4r1 OFJvBUE5zPEEF-Ja5JloWs3rESZDZDFMLOVC51 BB1 ik1 EgfsKIXTyW75Q Scale = 1:79.5 5.00 12 5x6 = 7 2.50 12 5x6 : 5x6 : 27 28 6 g 5 • 29 • 6x6 4x8-'- ••• 8 •••••• 4x8: q • 19 • r 11 • • 9 • o 4x10 : 3 36 Sx12 7••••�r7 ••• •••1 2 35 12 • 4x6 = 24 26 9j 4x4 : ••• ••• • 10 • • 38 20 i8. 22 x10 MT20H� 12 • ••••• •• 48.11 4xfi •I;- • • • 30 233125 32 33 16 34 17 15 14 • •••••• • •• ••••• 21 4x10 II 3x8 II 4x8=4x16= 3x4 II •••••• •• ••• i •••••• • •••••• • • • • •• • •••••• • • - •••••• • 4a-s-a i 2-0-0 i 7-11-0 16-3-8 i 24-8-0 i26-8-11i 33-4-12 i 42-1-8 42-9r8 i 1 2-0-20 5-11-0 8-4-8 8-4-8 2-0-11 6-8-1 8-8-12 8-b 21 QO Plate Offsets (X,Y)-- [1:0-8-13,0-0-7], [1:0-0-7,2-8-14], [2:0-4-12,0-2-0], [4:0-2-8,0-2-0], [6:0-3-0,0-2-12], [8:0-3-8,0-2-12], [10:0-4-4,0-1-12], [11:0-6-0,0-5-8], [13:0-6-4,0-2-0], [15:0-6-0 0-2-0] [17:0-4-4 0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.33 TC 0.80 Vert(LL) -0.56 13 >727 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.33 BC 0.66 Vert(CT) -1.03 14 >397 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.96 Horz(CT) 0.29 10 n/a n/a BCDL 10.0 Code FRC2017/TP12014 Matrix-MSH Weight: 304 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x6 SP No.2 *Except` TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. T1: 2x6 SP No.1 D BOT CHORD Rigid ceiling directly applied or 4-0-0 oc bracing. BOT CHORD 2x6 SP No.2 *Except* WEBS 1 Row at midpt 2-15, 13-15, 4-13, 6-11, 8-11 133: 2x4 SP No.2, 134: 2x6 SP No.1 D WEBS 2x4 SP No.2 *Except* W1,W11: 2x6 SP No.2, W2: 2x4 SP No.2D WEDGE Left: 2x4 SP No.2 REACTIONS. (lb/size) 1=-416/0-8-0 (min. 0-1-8), 10=2014/0-8-0 (min. 0-2-6), 17=3329/0-8-0 (min. 0-3-15) Max Horz 1=294(LC 9) Max Uplift1=-416(LC 1), 10=-549(LC 10), 17=-1221(LC 5) Max Grav 1=179(LC 9), 10=2014(LC 1), 17=3329(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 22-24=-580/1220, 24-26=-1319/2731, 2-26=-1310/2806, 2-3=-2388/1081, 3-4=-2250/1096, 4-5=-6429/3224, 5-6=-6286/3224, 6-27=-3463/1817, 7-27=-3397/1834, 7-28=-3834/1987, 28-29=-3849/1970, 8-29=-4025/1954, 8-19=-580/276 BOT CHORD 23-31=-1032/427, 25-31=-1032/427, 25-32=-2649/1171, 17-32=-2649/1171, 17-33=-2649/1171, 16-33=-2649/1171, 15-16=-2649/1171, 13-14=0/285, 5-13=-390/251, 13-35=-3060/6335, 12-35=-3058/6341, 12-36=-3023/6250, 11-36=-3010/6266, 11-37=-335/301, 10-37=-356/283, 10-38=-335/714, 20-38=-335/714 WEBS 2-17=-2939/1529, 2-15=-2260/5001, 4-15=-1717/985, 13-15=-1063/2275, 4-13=-1970/3964. 6-11=-3010/1585, 7-11=-854/2131, 8-11=-1554/3274, 8-10=-2059/1520, 19-20=-357/249, 23-24=-381/844, 22-25=-971/409 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=175mph (3-second gust) Vasd=136mph; HVHZ; TCDL=5.Opsf; BCDL=5.Opsf; h=16ft, Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 4-5-12, Interior(1) 4-5-12 to 28-3-9, Exterior(2) 28-3-9 to 37-3-2, Interior(1) 37-3-2 to 40-3-12, Exterior(2) 40-3-12 to 44-9-8 zone; cantilever left and right exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 416 lb uplift at joint 1, 549 lb uplift at joint 10 and 1221 lb uplift at joint 17. 6) This truss has been designed for a moving concentrated load of 200.011b dead located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard STANDARD LATERAL WEB BRACING u.v SHALL BE CONNECTED TO A FIXED RIGID POINT OR X—BRACED AS NOTED ON THIS DETAIL. 2x4 LATERAL BRACE PER TRUSS DESIGN WITH 2-10d NAILS PER WEB FOR FORCES UP TO 4600 lbs. FORCES IN EXCESS OF 4600 lbs. REQUIRES 2x6 #3 OR BETTER. NOTE: • • • • • • • PROVIDE X—BRACQVG•AT 20'—•d'•• INTERVALS FGP*6 E@•FORCES UP TO 2509 lbs. ql" AT 10'—G: FOR FORCE GREAT%.T�A 2501 Ids•• LATERAL BRACIN•'OE; ,�."jL • --- Al_T. LATERAL BRACING DETAIL -10d 0 6" 0, C. TYP, T—BRACE SAME SIZE TRUSSES @ 24" AND GRADE AS WEB. O.C. TYP. WEB (2x6 MAX.) WI TH i ®6" WEB SECTION DETAIL NOTE: BRACE MUST BE 80% THE LENGTH OF THE WEB, THIS DETAIL IS TO BE USED AS AN ALTERNATE FOR CONTINUOUS LATERAL BRACING. MINIMUM GRADE OF LUMBER TPI-2007 Mohmoud Zolfoghori T.0SEE STRUCTURAL SHEET. 13901 S.W. 108 Ave. ...... Revised: Miomi, FL. 33176 B.0...... SEE STRUCTURAL SHEET. 7/7/94 305-253-2428 WEBS —SEE STRUCTURAL SHEET. 03/2012 P.E. No. 36921 LOADING (PLF L. D. STIR. INCR.: 33� DRAWN BY: G.L.H.��� Fo T.C. 30 15 CHECKED BY: J.A.I. r U %✓ //� B.G. 0 10 SPACING: 24 INCH 0 C. REP. STRESS: YES MITek Industries Inc. Approved for MITek Industries Inc. R a General' Notes Notes generates Trusses are not marked in any way to identify the Los trusses no estan marcados de ningun modo que frequency or location of temporary lateral restraint identifique la frecuencia o /ocalizac/6n de restricci6n and diagonal bracing. Follow the recommendations lateral y arriostre diagonal temporales. Use las for handling, installing and temporary restraining recomendaciones de manejo, instalaci6n, restdcci6n and bracing of trusses. Refer to BCSI - Guide to y amostre temporal de IDS trusses. Vea el folleto BCSI Good Practice for Handling, Installing,Res a n Restraining 9. 9 - is de Buena Practice Para all Maned, InstalaciiSn Gu u P 1 & Bracingof Metal Plate Connected Wood 1 Restriccibn Arriostre de IDS Trusses de Madera y Trusses* for more detailed information. Conectados con Placas de Metal* Para informaci6n Truss Design Drawings may specify locations of mas detallada. permanent lateral restraint or reinforcement for Los dibujos de diseno de Ids trusses pueden especificar individual truss members. Refer to the BCSI.B3* las localizations de restdcci6n lateral permanente o for more information. All other permanent bracing refuerzo an los miembros individuales del truss. Vea design is the responsibility of the building designer. la hoja resumen BCSI.83* Para mas informaci6n. El resto de Ios diseios de arriostres permanentes son la responsabilidad del diseiador del edificlo. DANGER The consequences of improper handling, erecting, installing, restraining and bracing can result in a collapse of the structure, or worse, serious personal injury or death. !PEL!GRO! El resultado de un manejo, levantamiento, instalacibn, restricci6n y arrisotre incorrecto puede ser la caida de la estructura o arm peon, heridos o muertos. A((of] Exercise care when removing banding and handling trusses to avoid damaging trusses and prevent injury. Wear personal protective equipment for the eyes, feet, hands and head when working with trusses. II L, Utilice cautela at quitar las ataduras o los pedazos de metal de sujetar Para evil dano a los trusses y prevenir la herida personal. Lleve at equipo protective, personal Para Ojos, pies, menos y cabeza cuando trabalia con trusses. A @&UVOOO(nl Use BC1�1 1 special care in Utilice cuidado windy weather or especial an near power lines dias ventosos o Handling o Manelo and airports. Cerra de cables el6ctricos o de aeropuertos. Avoid lateral bending. Spreader bar for truss \' Evite la flexOn lateral. a IrIPPOMI The contractorAg \ is responsible for O O properly receiving, unloading and storing the trusses at the Use proper rigging and Use equipo aprop/- jobsite. Unload trusses to smooth surface hoisting equipment. ado Para levantar to prevent damage. e improvisor. El contratista tiene la responsabilidad de recibir, descargar y almacenar adecuadamente IDS trusses en la obra. Descargue los trusses sobre una supericie Asa Para prevenir at dano. k � Trusses may be unloaded directly on the ground at the time of delivery or stored temporarily in contact with the ground after delivery. If trusses are to be stored for more than one week, place blocking of sufficient height beneath the stack of trusses at 8' (2.4 m) to 10' (3 m) on -center (oc). Los trusses pueden ser descargados directamente an at Sul en aquel momento de entrega o alma- cenados temporalmente an contacto con el suelo despues de entrega. Si los trusses estarin guarda- dos Para mas de una semana, ponga bloques de altura suficiente debajo de la pila de IDS trusses a 8 hasta 10 pies en Centro (oc). (S)DO NOT NO almacene verti- store unbraced calmente IDS trusses bundles upright. sueltos. If trusses are to be stored for more than one week, G)DO NOT store on NO almacene en cover bundles to protect from the environment. uneven ground. tiers desigual. Para trusses guardados por mas de una Samaria, cubra IDS paquetes Para protegerlos del ambiente. Refer to BCSI* for more detailed information pertaining to handling and jobsite storage of trusses. Vea at folleto BCSI* Para information mas detallada sobre e/ manejo y almacenado de IDS trusses an el sitio de trabalo. Hoisting and Placement of Truss Bundles Recomendaciones para levantar paquetes de trusses DON'T overload the crane. NO sobrecargue la gr6a. NEVER use banding to lift a bundle. NUNCA use las ataduras Para levantar un Pa9 uete. A single lift point may be used for bundles of top chord pitch trusses up to 45' (13.7 m) and parallel chord trusses up to 30' (9.1 m). Use at least two lift points for bundles of top chord - WA R t4I IN G Do not overload supporting pitch trusses up to 60' (18.3 m) and parallel chord structure with truss bundle. trusses up to 45' (13.7 m). Use at least three lift No sobrecargue la points for bundles of top chord pitch trusses >60' estructura apoyada con el paquete de (18.3 m) and parallel chord trusses >45' (13.7 IT). drusses.• Puede user un solo lugar de levantar pars paquetes • • • • • de trusses de la cuerda superior hasta 45'2 trusses lace truss bundles olcl•t4 :position. de cuerdas parelelas de 30' o menos. Use yip• Pwo Wlquetes de trusses4er) una menos dos puntos de levantar con grupos de trusses Qosici6n dStable. • de cuerda superior inclinada hasta 60' y trilliti i • • • • • • • • • • cuerdas paralelas hasta 45. • • • • • • • • • Use por to menos dos puntos de levantar con grupos de trusses de cuerda superior Net "_ armas de 60' y trusses de cuerdas paraletas mas de 4614 • • • • • • • •••••• • •••• ••••• Mechanical Hoisting Recommendations foe Single T�us�es Recomendaciones para levapias trusses I1n�ividuaMos • • • • fi • • 991111060 • • Using a single pick -point at tt�y 6 damage the truss. • • El Lso de un solo lugar en el pico papa levantapuede • • • • 0649 hacer dano al truss. • • • • • • • • • • • r; 60' of a s• • • •• • • • • 00000 • Approx. 1/2 y truss length Tagline . TRUSSES UP TO 30' (9.1 ni Steps to Setting Trusses Las medidas de la instalacion de los trusses 1) Install ground bracing. 2) Set first truss and attach securely to ground bracing. 3) Set next 4 trusses with short member temporary lateral restraint (see below). 4) Install top chord diagonal bracing (see below). 5) Install web member plane diagonal bracing to stabilize the first five trusses (see below). 6) Install bottom chord temporary lateral restraint and diagonal bracing (see below). 7) Repeat process with of four trusses until all trusses are set. groups 1) Instate IDS arriostres de tiers. 2) Instale el primero truss y ate seguramente al arriostre de tierra. 3) Instale IDS r6ximos 4 trusses con restricci6n lateral temporal de miembr p p o Corte (vea abajo). 4) Instale el arriostre diagonal de la cuerda superior (vea abajo). 5) Instale arriostre diagonal Para IDS pianos de los miembros secundarios Para estabf/ice IDS primeros cinco trusses (vea abajo). 6) Instale la resMc- ci6n lateral temporal y arriostre diagonal Para /a cuerda inferior (vea abajo). 7) Repita este proced- imiento an grupos de cuatro trusses hasta que todos IDS trusses esten instalados. JjJUU= Refer to BCSI.B10 for trusses spaced greater than 2' oc. Consulte BCSI-B10 Para trusses espaciados a This de Zen el Centro. Restraint/Bracing for All•Planes of Trusses RestriF4 6s"rrlios1A•l todo.; pla%ps de trusses • Minimum luml»r used for lateral Wliraiiii1t and diagc:al arW.Weis 2x4 stress -graded lumber. Attach to each truss vi at least 2-10d (0.128x3"),*-12d (0.128x3.25 ) or 2-16d (0.131x3.5") nails. La maderaZAZlA&Sda por estrAA19lt1adera miniA"MaIllIallpara restricci6n lateral y arriostramiento diagonal. Ajprlas a cage braguere con l minimo 2 clavci 46: fP.JVx3 ), 12d (0.128x3.25) o l6d (0.131x3.5 ). This restr• j 1iTana &%ling metho(j is forte trusses ex"6342 and 4x2 parallel chord trusses (PCTs). See top of next column for temporarl reatraint and a racing oi Este mBtoi t*&ci6n y anndiltfb as lAra todo trWGA641fAcepto trusses de cuerdas paralelas (PCTs) 3x2 y 42. V*l"ire superio" 41 cojumna pare 04eitWn y amiostre temporal de PCTs. 1) TOP CHORD PLANE - Q!EADA SUPERIOR • rtfss it "' $' fip�)1ortS` , porary' a I Restraint (TCTLR) Spacing Longitud 4eTramo Espacfailiento del Arrioete•RAtl/Ural de la Cuerda Superior UpRs311D• • • • • • A'(3 m) o(Pn ax. • ( 1 m) • • 3011111-111 • • (9.1 A13.7 ni • • 8:2.4frg),pPmax. 45'- 60' (13.7 m - 18.3 IT) • 6' (1.8 m) oc max. 60'- 80' * (18.3 m - 24.4 m)* 4' (1,2 m) oc max. TRUSSES HASTA 30 PIES I reader bar 'Consult a Registered Design Professional for trusses longer than 60' (18.3 rm *Conspire a un Professional Registrado de Diselo Para trusses mas de 60 pies. / Too-in� T�oe-in Attach Locate Spreader bar 10' (3 m) See BCSI-B2*for TCTLR options. 'A - Spreader bar 1/2 to -� above or stiffback oc max. mid -height Vea el BCSI-82* Para las opoiones de TCTLR. Tagline 2/3 truss length 1 TRUSSES UP TO 60' (18.3 m) _� TRUSSES HASTA 80 PIES �� Refer to BCSI-B3* <_2' oc P. for Gable End Frame restraint/bracing/ ""` _ A Hold each truss in position with the erection equip- Spreader bar 2/3 to reinforcement information. ____ s 45 ment until top chord temporary lateral restraint is 3/4 truss length I Para informacibn sobre restricci6n/ TCTLR installed and the truss is fastened to the bearing Tagline arriostre/refuerzo Para Armazones TRUSSES UP TO AND OVER 60' (18.3 in points. f- TRUSSES HASTA Y soe RE 60 PIES Hasliales vea el resumen BCSI-B3* Sostenga cada truss an posici6n con equipo de Note: Ground bracing not shown for clarity. 10" or> gl is hasta que IS restricci6n lateral temporal de /a Truss attachment cuerda superior este instalado y el truss est6 asegurado an los soportes. Repeat diagonal braces for each set of 4 trusses. required at support s) Repita IDS arrisotres diagonales Para cada grupo de 4 trusses. Section A -A Installation of Single Trusses by Hand Recommendacciones de levantamiento de trusses individuales LATERAL RESTRAINT & DIAGONAL BRACING ARE por la mano VERY IMPORTANT Trusses 20' - " f � - � � - Trusses 30' •LA RESTRICCION LATERAL Y EL ARRIOSTRE DIAGONAL SON (6.1 m) or less, support near peak. - � ' � (9.1 m) or less, support at quarter points. _ �� I d MUY IM;PORTANTES! Diagonal Continuous Lateral Restraint 2) WEB MEMBER PLANE- ��� (CLR) splice reinforcement PLANO DE LOS MIEMBROS bracing Soporte Soporte an Truss Member SECUNDARIOS �\ 2x_ CLR cerca del IL los puntos pico Ios de cuarto los Trusses u to 30' trusses de E Trusses up to 20' E P 20 pies o (6.1 m) trusses de 30 (9.1 m) menos. Trusses hasta 20 pies pies o menos. Trusses haste 30 pies Temporary Restraint & Bracing Restriccidn y arriostre temporal 12167M Refer to BCSI-B2* for more information. Top Chord Temporary Vea at resumen BCSI-82* Para mas informaci6n.leiei Lateral Restraint (TCTLR) Locate ground braces directly in line with all rows 2x4 min. of top chord temporary lateral restraint (see table in the next column). Coloque Ios arriostres de tiers pars el primer truss s Too, typ. directamente an Anea con cada una de las fllas de Brace first restricci6n lateral temporal de /a cuerda superior -90° (vea la table an IS pr6xima columi truss securely () DO NOT walk on unbraced trusses. before NO camine sobre trusses sueltos. t- erection of additional DO NOT stand on truss overhangs until trusses. Structural Sheathing has been applied to the truss and overhangs. 4 NO se pare an vo/adizos catches haste Revestimiento estructural ha side aplicado a IS armadura y vo/l ottom chords Minimum 2' 2x- Scab block centered over CLR splice. Diagonal braces every Attach to CLR with minimum 10 truss spaces 20' 8-16d (0.135x3.5") nails each (6.1 m) max. side of splice or as specified 10' (3 IT) - 15' (4.6 m) max. by the Building Designer. Same spacing as bottom chord Note: Some chord and web members SECTION A -A lateral restraint not shown for clarity. 3) BOTTOM CHORD PLANE - CUERDA INFERIOR Truss Lateral Restraints - 2x4xl2' or greater - Member lapped over two trusses -- Note: Some chord or CLR splice reinforcement. �" �- _-.----- __- .' and web members Bottom not shown for chords =4� clarity. 10' (3 m) -15' (4.6 IT) max. Diagonal braces every 10 truss spaces 20' (6.1 m) max. Restraint & Bracing for 3x2 and 4x2 Parallel Chord,Tilusses Restriction y arriostre pars trusses de cuerdas paralelas 3x2 y 4x2 10' (3 m) or Diagonal bracing Repeat diagonal bracing Refer to BCSI-B7* 15' (4.6 mi every 15 truss spaces 30' for more information. / (9.1 m) max. Vea el resumen BCSI.B7* Para ` 4 mas informaci6n. r typ. I - Apply diagonal brace to vertical _ 2 oc, webs at end of cantilever and at bearing locations. All lateral restraints lapped at least two trusses. *Top chord temporary lateral restraint spacing shall be 10' (3 m) oc max. for 3x2 chords and 15' fd R rut or. for AY9 rhnrdt Installing - Instalacion Tolerances for Out -of -Plane. D/50 D (ft.) Tolerancias Para Fuera-de-Plano. Length -►I Max. Bow 1/4" 6 mm 1' 0.3 m 1'.. 13 mm 2' 0.6 m Max. Bow Length �� T i 3/4" 19mm 3' 0.9m Max. Bow r i 1" 25 mm 4' 11.2 m n i E------Lengm - - --------- - - m , Plumb 0 l Tolerances for Outof- /r Plumb. Tolerancias Para Fuera-de- D/5o max 1-1/4^ 32 rum 5' 1.5 m 1-1/2" 38 mm 6' 1.8 m Plonrl 1-3/4" T 44 mm 2.1 m 51 rum >_z.4 in Construction Loading Carga de construction DO NOT proceed with construction until all lateral restraint and bracing is securely and properly in place. NO proceda con la construction hasta que todas las restric- crones laterales y IDS arnostres estdn colocados en forma apropiada y segura. DO NOT exceed maximum stack heights in table at right. Refer to BCSI-B4* for more information. NO exceda las alturas maximas de mont6n. Vea el resumen BCSI-/84*Para mas informacii Ad= ArINIF 1. Based on truss live load of 40 psi or greater. For other conditions, contact -@ a Registered Design Professional. ., 2. Install stacks of materials as quickly as possible. NEVER stack materials near a peak, at mid -span, on cantilevers or overhangs. NUNCA apile los materiales cerca de un pico, a Centro de la luz, en cantilevers o ateros. DO NOT overload small groups or single trusses. NO sobrecargue pequefios grupos o trusses individuales. Place loads over as many trusses as possible. Coloque las cargas sobre tantos trusses come sea posible. Position loads over load bearing walls. Coloque las cargas sobre las Paredes soportantes. Alterations - Alterations 007M Refer to BCSI-B5.* Truss bracing not shown for clarity. Vea et resumen BCSI-B5. * DO NOT cut, alter, or drill any structural member of a truss unless specifically permitted by the truss design drawing. NO Corte, altere o perfore ningun miembro estructura/ de un truss, a Aw menos que estd especificamente permitido en el dibujo del diseno del truss. Trusses that have been overloaded during construction or altered without the Truss Man- ufacturer's prior approval may render the Truss Manufacturer's limited warranty null and void. Trusses que se han sobrecargado durante IS construcci6n o han sido alterados sin /a autor- izaci6n previa del Fabricante de Trusses, pueden hacer nulo y sin efecto /a garantfa limitada del Fabricante de Trusses. 'Contact the Component Manufacturer for more information or consult a Registered Design Professional for assistance. NOTE: The truss manufacturer and truss designer rely on the presumption that the contractor and crane operator (if applicable) are professionals with the capability to undertake the work they have agreed to do on any given project. If the contractor believes it needs assistance in some aspect of the construction project, it should seek assistance from a competent party. The methods and procedures outlined in this document are intended to ensure that the overall construction techniques employed will put the trusses into place SAFELY These recommendations for handling installing, restraining and bracing trusses are based upon the collective experience of leading personnel involved with truss design, manufacture and installation but must due to the nature of responsibilities involved be presented only as a GUIDE for use by a qualified building designer or contractor Its not intended that these recommendations be interpreted as superior to the building designer's design specification for handling, installing, restraining and bracing trusses and it does not preclude the use of other equivalent methods for restraining/bracing and providing stability for the walls, columns, Floors, roofs and all the interrelated structural building components as determined by the contractor. Thus, SBCA expressly disclaims any responsibility for damages arising from the use, application, or reliance on the recommendations and information contained herein_ SBCA 6300 Enterprise Lane - Madison, WI 53719 608-274-4849 - sbandustry.com B1 WARN11 x17 200804