BPP-07-19-1602, 1361 NE 104th St (4)sHoOn' Miami Shores Village
�� Building Department
PJ_�,- ,
10050 NE 2nd Ave.
Fioninv Miami Shores, FL 33138
305-795-2204 / Fax 305-756-8972
NOTICE TO MIAMI SHORES BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL
INSPECTOR UNDER THE FLORIDA BUILDING CODE.
I (We) have been retained by Florida Foundation Systems to perform special inspector services under the Florida
Building Code 5tn Edition (2014) and Miami Dade County Administrative Code at the 1361 N.E. 104th Street
project on the below listed structure as of 12/13/19 (date). I am a registered
arch itect/professio n al engineer licensed in the State of Florida.
Process Number:
XSecial Inspector for Reinforced Masonry, Section 2122.4 of the FBC 51h Edition (2014)
Miami Dade County Administrative Code, Article II Section 8.22 Special Inspector for
_ Trusses > 35 ft. long or 6 ft. high
""' •
_ Steel Framing and Connections welded or bolted
.
—Soil Compaction 000000
.
Precast Attachments •
•
_
.. 00
Roofing Applications, Lt. Weight. Insul. Conc. • •; • •;
Other Pile Installation Monitoring
00000,
Note: Only the marked boxes apply.
The following individual(s) employed by this firm or me is authorized representative to pirfov. .
•
inspection* "
• •
1. Naresh Persaud, FLEW 1100008977 2.
• • • •
3. 4.
*Special inspectors utilizing authorized representatives shall insure the authorized representative is qualified by
education or licensure to perform the duties assign by Special Inspector. The qualifications shall include licensure as a
professional engineer or architect: graduation from an engineering education prograin in civil or structural engineering;
graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination;
or registration as building inspector or general contractor.
I (we) will notify the Miami Shores Building Department of any changes regarding authorized personnel
performing inspection services.
I (we), understand that a Special Inspector inspection log for each building must be displayed in a
convenient location on the site for reference by the Miami Shores Building Department Inspector. All
mandatory inspections, as required by the Florida Building Code, must be performed by the Miami Shores
Building Department .Inspections performed by the Special Inspector hired by the owner are in addition to
the mandatory inspections performed by the department. Further, upon completion of work under each
Building Permit, I will submit to the Building Inspector at the time of the final inspection the completed
inspection log form and a sealed statement indicating that, to the best of my knowledge, belief and
professional judgment those portions of the project outlined above meet the intent of the Florida Building
Code and are in subst`�tiabu000,> knce with the approval plans.
oN M ES, ,,,, Engineer/fit.
` ENSE Natne Mark A. Mesiano, P.E. 48202
Signed and i?e ed' Print
Date: 12/1�1� ; 48202 Address 250 S.W. 13th Ave., Pompano Beach, FL 33069
* � 01F Cc -
10 N I-\'- `'�
Z3
Proposal
for
Prepared for
Designer Pools
REVISED 713/19
by
Melanie Repollet, Office Administrator
OVER 20 YEARS'" • too
LICENSED
PLANNING a t�6 i iN;
INSTALLATION & RE
lk=] � I I WYAJ
74,>1 FOUIMMAX71131M
iIIIIF QUALITY AND SERVICE YOU CAN BUILD ON
FLORID-A,s
FOUNDATION
i� QUALITY AND SERVICE YOU CAN BUILD ON
2030 NW 22ND COURT • POMPANO BEACH, FL 33069
(954) 977-2000 • (800) 861-3637 • FAX (954) 782-9991 • WWW.FLORIDAFOUNDATIONSY5.COM
CUSTOMER INFORMATION
Comoanv
Contact
Designer Pools
Job Name
Email
Zetka Residence- New Pool
info.designerpools@gmail.com
Address --—
City, State, ZIP —
-
1361 NE 104th Street
Miami Shores, FL
Job Number
Date
Bid Due
Phone
Phone
_
19324-1
REVISED 713/19
ASAP
305-969-6300
SCOPE OF WORK
DEPTH
OTY
UNIT P'F CE.
AlftbiP
Install Helical Piles: 3" SCH 80 12" 14"
28,
15
$ 879.0a •
$ 33A14 00
Pile Caps: 12" x 12" x 1/2" w/ 2 hooks
15
• • •.
Ind
•
Engineer to monitor install and provide signed and sealed pile logs.
1
• •. •
' • • Incl .
OTHER CHARGEABLE ITEMS
OTY
UNIT P I&
AMb.UNT '
$ r,500.00
Mobilization of equipment
TOTAL
. U625.110
ADDITIONAL DEPTH
If a depth greater than 28' feet is required to achieve design loads of 12 ton (C )/ 6 ton (T) it will be billed
at $180.00 per 7' section and/or $150.00 per 5' section.
OUT OF SCOPE (EXCLUDED)
1. REPLACEMENT. Foundation prep, cutting and replacement of concrete.
2. RELOCATION. Pool/sprinkler pipes, electrical conduits, water, sewer, gas lines, unforeseen obstacles, etc. in the way of pile
install shall be moved and/or relocated.
3. PERMITS. Permits, processing and plans. 4. LAYOUT. Survey piling layout
5. FIELD SUBMITTALS. Available as needed. Signed and sealed engineer_submittals will incur additional charges.
OTHER TERMS & CONDITIONS
1. ESTIMATE. This is an estimate. The final bill will reflect the actual work performed.
2. PRICE ADJUSTMENT. Florida Foundation Systems reserves the right to adjust the price per pile if quantity changes.
3. EXTRAS. Extras, including but not limited to additional depth, signed/sealed submittals etc. due at completion.
4. ADDITIONAL DEPTH. Depth beyond the value stated above to achieve loads does not require a written change order.
5. ADDITIONAL PILES. Additional piles shall be charged at contract price. Credit for deducted piles will be determined at
invoicing depending on final count.
6. SOIL/ENGINEERING TESTS. Proposal subject to change per results of soil tests/final engineering plans.
JOB SCHEDULE DRAW SCHEDULE
Job Start Date TBD 30% At contract acceptance $4,388
Estimated job duration 2 days 70% At completion $10,237
Authorized Signature Date Print Name and Title
LICENSED & INSURED LICENSE NO. CG-COS3441
Page 2
If FLORIDA
Fouriomn0N
J0 Sy" TM
. o#1 5
Florida Foundation will not be responsible for, but not limited to any damage to landscaping, sod, sprinklers,
septic tank, drain fields, pipes, underground utilities, etc. Florida Foundation will, however exercise reasonable
care in the installation of Pilings in a workmanlike manner. Client shall disclose any knowledge of debris, junk
fill, pressure grouting and obstruction of any kind in the proposed work area. If obstructions are encountered
that restrict the installation of the Pilings Florida Foundation reserves the right to relocate the piles with your
engineer's advanced approval, if necessary, up to three (3) helical diameters or more to achieve proper
penetration. It may be necessary to install two (2) piles instead of one to achieve the desired structural integrity
of the project due to obstructions or other problems. A price adjustment will be made in these cases.
Any alteration or deviation from above specifications will become an extra charge over and above the estimate.
All agreements contingent upon strikes, accidents, weather or other delays beyond our control. No owner may
incur any expenses to be charged to the contractor or credited against this contract without previous written
approval by the contractor. Property owner to carry liability insurance. Florida Foundation will provide public
liabirity insurance and Workmen's compensation or waiver. We also reserve the right to use our insured certified
installer.
PAYMENTS: The contractor reserves the right to stop work until time progress payments accordgg'to- he
contract are paid and such work stoppage, if any, shall not constitute grounds for breach of anyeo"tr"tual :...;•
obligations. Owner's failure to make full and timely payments to the contractor shall void contra ctof L'Abligation
under the warranty. Final payment is due and payable at completion. 0900,
• •
TERMS: A finance charge of 1'/z% per month will be applied to any remaining balance past due"Oer.30 days. Ti*
Florida Foundation incurs any expense in collecting payments or enforcing the terms of this acfieewoent the `•• ;
owner agrees to pay all such costs and expenses including reasonable attorney's fees and corR000at on the trial'
and appellate level, which contractor incurs. •
Suit for enforcing this agreement shall be filed in Broward County. If for any reason the speciffttiorls of this • •
contract cannot be met, either party may terminate the work by written notice. All work and costs up to th 1%inio
will be due and payable to contractor.
ANY CLAIMS FOR CONSTRUCTION DEFECTS ARE SUBJECT TO THE NOTICE AND CURE PROVISIONS
OF CHAPTER 558, FLORIDA STATUTES.
FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND
Payment may be available from the Florida Homeowners' Construction Recovery Fund if you lose money on a
project performed under contract, where the loss results from specified violations of Florida law by a licensed
contractor. For information about the recovery fund and filing a claim, contact the Florida Construction Industry
Licensing Board.
Respectfully submitted: Florida Foundation Systems, Inc. IThis proposal may be withdrawn by Florida
Foundation Systems, Inc. if not accepted within 30
Authorized signature h,,n .:, lfr. =v `'� Office; Administrall 'days.
Acceptance of proposal —__�
The above
Authorized signature
Print Name & Title
Date
r•a••
Page 3
Subsoil Investigation Report
prepared by:
• • • •
d
e a ra
• • • • •
•
i:••••:
9in*4"ertnq****q:•
00
•
• •
esAng;••1n�•.
• • • • • •
• • • • • •
• • • • • •
•
•
• • •00000
•
• • • • • •
Client: Eric Zetka
Contact: Eric Zetka
Address: 1361 NE 104th Street
Miami Shores, FL 33138
Project: Proposed Swimming Pool
Address: 1361 NE 104th Street
Miami Shores, FL 33138
Date: Wednesday, March 13, 2019
n=cat ; Materials -resting g Inspections I Environmental
'M i� Phone: 954-784-2941
r
*� E-Fax: 954-784-7875
admcr�gineering www.fef -eng.com
r, www fed eng coin
e ■ �®p
# g p Inc.�
Table of Contents
Client Information---------------------------------------------------------------------------pg.
1
Project Information-------------------------------------------------------------------------pg.
1
General Soil Descriptions-----------------------------------------------------------------pg.
1
Foundation Recommendations------------------------------------------------------------pg.
2
Excavations----------------- ------------------------------------------------------------ -----pg. 3
Grading--------- —------------------------------------------------------------------------------ pg. 3
Appendices-------------------------------------------------------------------------------------
t)g•+-�..
......
Soil Boring Log(s)
Laboratory Test(s)
•
.. ..
Project Location
• •
..
......
•
Soil Boring Location(s)
'
Soil Classifications
:... ;
Sampling Procedures
'
Limitations of Liability
For Your Information
Our findings in this report are based on soil conditions encountered in the test bore locations only, proposed structure to
be built, (if available at this stage), Florida Building Code requirements and standard engineering practices. If your
report is preliminary (i.e. vacant land or building to be demolished) additional borings are required within the foot print
of the proposed structure once the location & layout of the proposed structure is known.
Please read this report in its entirety and follow all recommendations. Failure to do so may result in the permitting
agency (Building Department, etc.) withholding the Certificate of Occupancy. This will cause delays and additional
costs. The Permitting Agency will require a final certification or signing off of the project prior to issuing the Certificate
.of Occupancy. All of our recommendations need to be followed to receive a final certification from F.E.T., including
densities on each lift, demucking verification, piling inspection, etc., whichever recommendation applies to your
project.
Please schedule us at least 24 hours in advance for all tests and inspections. If you choose to use another Engineering
Firm, you must verify they will provide you with the proper certification in writing, as outlined in our report. Our firm
will only provide a certification letter if it has verified all work as recommended in our report.
_. aci MiAMiDADE � t 1
R
N E.i'e
Q ederal
Q ngineering
8� � eating, Inc.
Wednesday, March 13, 2019
Eric Zetka
1361 NE 104th Street
Miami Shores, FL 33138
Attn.: ' Eric Zetka
RE: . Subsoil investigation
Proposed Swimming Pool
1361 NE 104th Street
Miami Shores, FL 33138
Dear Sirs:
Phone: 954-784-2941
E-Fax: 954-784-7875
admin@fed-eng.com
www.fed-eng.com
•t�s�w 01
Job Order Number 19SB147
•
•••• ••••••
• .... • . •
Pursuant to your request, Federal Engineering & Testing, Inc. has completed a subsoil investigation oW 03/12/20 9 et the ......
above referenced site. The purpose of our investigation was to verify subsoil conditions: IMAlve to fodndation • •
preparation and design. • • ' • • • • •
.. . . ••
• • A total of one (1) SPT boring was performed according to ASTM D-1586 drilled down to a depth of thirty fee {Za) and
one (1) DCP boring was performed according to ASTM D-6951 drilled down to a depth of fifteen feet (15) below the
existing ground surface. (See attached field sketch for locations). The following is a general description of soil stratas for
the subject site:
Depth
Dept[o
I)esc:riptitm of SmIs
0"
6"
Topsoil & Vegetation
6"
2'
Brown Sand with Rock
2'
5'
Pale Brown Sand with Rock
5'
10'
Light Brown Sand with Muck
10'
13'
Muck (31.4% Organics)
13'
18'
Brown Sand
18'
23'
Pale Brown Sand with Rock
23'
30'
ILimerock
Groundwater table elevation was measured immediately at the completion of each boring and was found at an average
depth of five (5) feet below existing ground surface. Fluctuation in water level should be anticipated due to seasonal
variations and run off as well as varying ground elevation, construction dewatering and pumping activities in the area.
Site contractor must familiarize himself with site conditions in the event groundwater controls and dewatering is needed.
Surface flooding may result under hurricane conditions and should be taken into consideration in the design of the
project. The contractor shall make sure that groundwater levels on adjacent properties are not affected by the contractors
dewatering activities. Specialty groundwater contractors shall be consulted for all work below the groundwater level.
The boring log(s) attached present a detailed description of the soils encountered at each location. The soil stratification
shown on the boring log(s) is based on the examination of the recovered soil samples and interpretation of the driller's
field log. It indicates only the approximate boundaries between soil types. The actual transitions between adjacent soil
types may be gradual.
Wednesday, March 13, 2019
1361 NE 104th Street
Miami Shores, FL 33138
Page 2
eral
ngineering
& esting, Inc.
Based on our understanding of the proposed structure and the information obtained from our field boring logs; it is
evident that deep foundation systems are needed to support the proposed new structure without detrimental settlement to
the structure.
Per the Florida Building Code FBC 2017, Chapter 18; deep foundation systems shall consist of one of the following
alternatives:
Allowable
Allowable Tension
Alternatives
Approximate Depth
Size
Compression file
• , .
1 ile Capacity •
AlloR 1 *Lateral•
Driven
'I'ons
apay�tn Tons
Capacity in
Tons.... •
•
Pin Piles/ Push Piers
25' - 30' or Refusal
4 Inch
5 Tons
1 Ton • • • • •
N/A
Helical Piles
25' - 30' or Refusal
3 Inch
12 Tons
6 Tons . • • • *
; •.NtA •
Auger Cast Piles
25'- 30, BELS
12 Inch
25 Tons
12 Tons.....
• • J T on
Auger Cast Piles
25' - 30` BELS
14 Inch
35 Tons
17 Tnnti• • • •
2 , .
.. .
*BELS - Below Existing Land Surface* • • • : • i ' • •
Estimated Lateral Load for a Pile Top Deflection of '/ inch. Proposed pile length based •o; the existing grout3d"
elevations at the time of drilling. Pile length may vary depending on proposed grade beam elevations aAd lt9consistent
soil profiles. In the case of pin, helical and precast piles a minimum of four (4) test piles shall be driven to determine
production pile length. All work shall be in accordance with the local Building Code and Coastal Zone Construction
Requirements (if required).
Helical pile bearing capacity is dependent on helix numbers, size and spacing. The foundation contractor will be able to
provide the most cost effective combination of helix designs. The above depths are the minimum depths required to
achieve design capacities. Predrilling might be required to achieve design depths.
All slabs and pool decks for the subject structure shall be designed as structural slabs spanning between supports and
designed by a Florida Registered Structural Engineer and placed under the supervision of a Geotechnical Engineer. All
work shall be conducted by an experienced Florida Licensed Specialty Piling Contractor. All piles shall be designed by
a professional engineer and shall be placed under the supervision of our Geotechnical Engineer to verify compliance
with our recommendations. If the pile is not reinforced over the entire length, we recommend a single #7 reinforcing
steel bar be placed the full length of the pile to verify pile continuity.
In case of existing structures in the vicinity of the pile driving operation, care shall be taken not to create excessive
vibration. Vibration levels shall be monitored to verify compliance with county regulations. Steps must be taken to
prevent excessive vibrations. In the event excessive vibrations are experienced during construction, alternative driving
methods shall be implemented (i.e.: predrilling, jetting, hydraulic push, etc...).
Any underground structures such as grease traps, septic systems, etc. must be supported on pile foundations, unless the
deleterious material (i.e.: silt, muck, peat, etc...) is excavated in its entirety and replaced with compacted washed gravel
such as pea rock or #57 stone below the water table elevations and clean granular materials above the water table.
Wednesday, March 13, 2019
•1361 NE 104th Street
Miami Shores, FL 33138
Page 3
ederal
ngineering
eating, Inc.
Excavations shall not extend within one (1) foot of the angle of repose next to existing footings or structures unless
underpinned. Trenching shall be in compliance with the Florida Building Code, OSHA and Trench Safety Act
requirements. Shorings shall be designed and inspected by a Florida licensed professional engineer.
Provisions shall be made by the architect, engineer of record and contractor to address differential settlements when
tying in new to existing structures. Mixing of different foundation types shall not be used unless provided with
expansion joints to address differential settlement.
:...'
All outside ground surfaces must be sloped away from the structure to avoid water accumulation apd ponditlg. All rain* •....
waters shall be discharged away from all building foundations. Verify all water, sewer, plumbing: p nkler Ld &ainage •,
lines are properly functioning with no leaks in the vicinity of the foundation. • • • • "
.... ......
Regardless of the thoroughness of a geotechnical exploration, there is always the possibility IM? conditions may be • • • •
different from those of the test locations; therefore, Federal Engineering & Testing, Inc. does i}Qb Urantee'an* lubsoir •' • •
condition between the bore test holes. A site plan showing the location of the proposed structure va4 riot provided at the 0000: •
time the soil borings were performed. Once plans and specifications have been finalized and drawn, Itderal-Engineering, ... ; .
& Testing, Inc. shall be provided a copy of the finalized plans and specifications for review. Pqr a nlbre accurate •
portrayal of subsurface conditions, the site contractor should perform test pits. If different conditions are encountered' •
Federal Engineering & Testing Inc., shall be notified to review the findings and make any recommendations as needed.
In accepting this report the client understands that all data from the soil borings is intended for foundation analysis only
and is not to be used for excavating, backfilling or pricing estimates. The site contractor must familiarize themselves
with the job site conditions.
Environmental analysis of the soil materials is not part of the scope of services. If environmental analysis of the soils is
required, we can provide a proposal for performing an environmental analysis of the soil materials. For Environmental
due diligence, a Phase I and/or Phase U Environmental Site Assessment is recommended.
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of
clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved
pending our written approval.
Federal Engineering & Testing, Inc. appreciates the opportunity to be of service to you at this phase of your project.
Please feel free to contact us if we may be of further service to you.
pie � SOHN 4e''�i�i
Sincerely, �e®,� ��,•®E��. �! 'i��
o rem �� r
No
B B �
Keith LeBlanc, P.E O'•, d%
Federal Engineering &ate r i'D C1��
Florida Reg. No. 59394 ,, I%3�,q� ®e`
Certificate of Authorization #
ederal
Q ngineering
VQ eating, Inc.
SPT Test Boring Report
Client: Eric Zetka
Project: Proposed Swimming Pool
Address: 1361 NE 104th Street
Miami Shores, FL 33138
Phone: 954-784-2941
E-Fax: 954-784-7875
admin@fed-eng.com
www.fed-eng.com
Date of Test: March 12, 2019
Hole No.: B-1
Location: See Attached Drawing
Depth (FT)
Soil Descriptions
Hammer Blows
: N" •
1
0" - 6"
Topsoil & Vegetation
3
...' 4:
: &
2
6" - 2'
Brown Sand with Rock
4
... •'9•
•
3
3 .....�
2'- 5'
Pale Brown Sand with Rock
• • • •
. A
4
5
.....d'
5
5 .....t
'
6
5' - 10'
Light Brown Sand with Muck
7
" "7
1
•
7
7 g
•
8
7
s •8
9
4 " 3
• ••
'.a..
10
10' - 13'
Muck (31.4% Organics)
5
4
11
A A
A
12
A
A
13
A A
A
14
13' - 18'
Brown Sand
A
A
15
11 11
22
16
11
12
17
A A
A
18
A
A
19
A A
A
20
18'- 23'
Pale Brown Sand with Rock
A
A
21
14 17
34
22
17
18
23
A A
A
24
A
A
25
A A
A
26
23'- 30'
Limerock
A
A
27
19 20
40
28
20
19
29
A A
30 1
A
A
A
Water Level: 518" Below Land Surface
A = Auger
Wednesday, March 13, 2019
1361 NE 104th Street
Miami Shores, FL 33138
Page 4
Appendiees
"ea,
ngineering
8� Q esting. Inc.
•
••••
• ••
•••••
••••••
••• •
•••••
•• ••
••
••••••
•
• •
• •
••••••
Dederal
AGgineering
Ofji esting, Inc.
Test Boring Report
Client: Eric Zetka
Project: Proposed Swimming Pool
Address: 1361 NE 104th Street
Miami Shores, FL 33138
Phone: 954-784-2941
E-Fax: 954-784-7875
admin@fed-eng.com
www.fed-eng.com
Date of Test: March 12, 2019
Hole No.: B-2
Location: See Attached Drawing
Depth (FT)
Soil Descriptions
Hammer Blows
"N"
•
1
0" - 6"
Topsoil & Vegetation
4
;..4':
S
2
6" - 2'
Brown Sand with Rock
4
...5..
3
3 ...s..
2'- 5'
Pale Brown Sand with Rock
. •..
Ll.
4
6
• •
• .
5
7 .••c7•.
. •
�..
6
2
.. Is
7
1 ; 0 0;
8
5'- 12'
Muck (26.5% Organics)
2
• 1.
9
1 so •
• •
10
1
2��
11
0 1
2
12
1
2
13
7 9
12'- 15'
Brown Sand
20
14
11
10
15
12 11
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Water Level: 5'3" Below Land Surface
A = Auger
edera l Phone: 954-784-2941
E-Fax: 954-784-7875
ngi neeri ng admin@fed-eng.com
www.fed-eng.com
esting, Inc. T __ •
Date: Tuesday, March 12, 2019
Report of Organic Content ASTM-D 2974
Job Order Number 19SB 147
Eric Zetka
1361 NE 104th Street
Miami Shores, FL 33138
Attn.: Eric Zetka
RE: Geotechnical Services • • • • • •
Proposed Swimming Pool • •
1361 NE 104th Street
Miami Shores, FL 33138 .. • • •
Results of Test ":' •; • • • •
Sampled by: MM Reported To: ::,::Client
Sample Location: See Location on Subsoil Drawing
Material Description: Muck •
Sample Location and Depth
Organic. Content Percentage
B 1
10' - 13'
31.4%
B2
5' - 12'
26.5%
B3
N/A
N/A
B4
N/A
N/A
B5
N/A
N/A
Tested By: Si
Checked By: KL
' MIAMMADE
E n adr f.
Appm,ed Ljr la!ery
Lgideratneering
sting, Inc.
Rz
Site Location Map
3370 NE Sth Avenue, Oakland Pak, FL 33334 (954) 784-2941r
Client: Eric Zetka Project: Proposed Swimming Pool
Test: Subsoil Investigation Project Address: 1361 NE 104th Street
(site map is not to scale) Miami Shores, FL 33138
c,�e� _x�ineeriata tf'
Client: Eric Zetka
Test: Subsoil Investigation
(site map is not to scale)
Soil Boring Location Map
3370 NE Sth Avenue, Oakland Park, FL 33334
Project: Proposed Swimming Pool
Project Address: 1361 NE 104th Street
Miami Shores, FL 33138
��ederal
f0ingineering
�ti,ftv)esting, Inc.
784-2941
Oederal
1� ngineering
& : sting, Inc.
Key Classifications & Symbols
Correlation of Penetration Resistance with Relative Density
Density and Consistency
Dynamic Cone Penetrometer
Penetrometer Resistance
Standard Penetration
Hamner Blows
Relative Density
-
U
0 - 10
0-3
Very Loose
10 - 25
3-8
Loose
--� 25 - 45
8 - 15
Firm
45 - 75
15 - 25
Very Finn •
75 -120
25 - 40
D4ns4'. •
> 120
> 40
Very. ense :..
1
U
0-6
_
0-2
Ver •Soft ..
6-15
2-5
Sdt •
-
-
iMq"•
30 - 45
10 - 15
$tiff,,,
45 - 90,
15 - 30
Very Stiff:
90 - 150
30 - 50
$arch •, •
" Rock Hardness Description
Soft
Rock core crumbles when handled
Medium
Can break core with your hands
Moderately Hard
Thin edges of rock core can be broken with fingers
Hard
Thin edges of rock core cannot be broken with fingers
Very Hard
Rock core rings when struck with a hammer
Quantity
Modifiers
Very Slight Trace
0 - 2
Slight Trace
2 - 5 %
Trace
5 - 10 %
Little Trace
10 - 15 %
Some
15 - 30 %
With
> 30 %
Silt - Clay Modifiers
Slightly Silty /Clayey
0 - 5 %
Silty / Clayey
5 - 30 %
Very Silty / Clayey
30 - 50 %
Particle Size
Boulder
> 12 in
Cobble
3 - 12 in
Gravel
4.76 min - 3 in
Sand
0.074mm - 4.76 mm
Silt
0.005 nun - 0.074 mrn
Clay
< 0.005 min
.000 .
Angederalineering
esting, Inc.
Drilling & Sampling Procedures
The soil borings were installed in accordance with Standard Penetration Tests procedures as set forth in ASTM D-1586.
Representative samples were collected utilizing spilt -barrel techniques in accordance with the procedures set forth in
"Penetration Tests and Spilt -Barrel Sampling of Soil in ASTM D-1586. The following field tests, measurements and
laboratory analysis were performed/collected during the installation of each soil boring.
......
Penetration Tests .'. ' •
During the sampling procedures, Standard Penetration Tests were performed at five (5) foot: tgrvals to•efoLin the
standard penetration value (N) of the subsurface soil. The standard penetration value (N) is ideatiUd as the number of• 0 0 •
blows of a 140-pound hammer falling thirty (30) inches, required to advance the spilt -barrel sampler ton a (1) foot into the: "
subsurface soil. The sampler was lower into the bottom of the previously cleaned drill hole and ddMdnced b; 48,0A fron-P • • •
the hammer. The number of blows was recorded for each of the three (3) successive incrp*V9onT; of six` t6) inches ""
.. ...0 0
penetration. The "N" value is obtained by adding the second and third incremental numbers.
. •
......
•• . • •• •
Water Level Measurements . .
••.•
Water Level depths were obtained during the test boring operations. In relatively pervious soils, such as sandy soils, the
indicated depths are usually reliable groundwater levels. Seasonal variations, tidal conditions, temperature, land -use and
recent rainfall conditions may influence the depths to groundwater levels.
Soil properties / Classification
All samples collected were classified in accordance with the Unified Soil Classification System criteria to determined
soil material properties and compared with published literature of the USDA Soil Conservation Survey.
Ground Surface Elevations
Ground surface elevations have not been provided for the proposed boring locations. Therefore, all references to depth
of the various strata and materials encountered were from existing grade at the time of the drilling operations.
Limitations of Liability
Warranty
.We warrant that the services performed by Federal Engineering and Testing,
-Inc. (F.E.T.) are conducted in a manner consistent with the level of skill and
care ordinarily exercised by members of the profession currently practicing
under similar conditions. No other warranties, expressed or implied, are
made. While the services of F.E.T. are an integral and valuable part of the
design and construction process, we do not warrant, guarantee, or insure the
quality -or completeness of services or satisfactory performance provided by
other members of the construction process and/or the construction plans and
specifications which we have not prepared, nor the ultimate performance of
building site materials. As mutual protection to clients, the public and
ourselves, all reports are submitted as the confidential property of clients, and
authorization for publication of statements, conclusions or extracts from or
regarding our reports is reserved pending our written approval. Reports are
not intended for 3rd parry use.
Subsurface Exploration
Subsurface exploration is normally accomplished by test borings. The soil
boring log includes sampling information, description of the materials
recovered, approximate depths of boundaries between soil and rock strata and
groundwater data. The log represents conditions specifically at the location
and time the boring was made. The boundaries between different soil strata
are indicated at specific depths; however, these depths are in fact approximate
and dependent upon the frequency of sampling. The transitions between soil
stratum are often gradual. Water level readings are made at the time the
boring was performed and can change with time, precipitation, canal levels,
local well drawdown, and other factors. Regardless of the thoroughness of a
Geotechnical exploration there is always a possibility that conditions may be
different from those of the test locations; therefore F.E.T. does not guarantee
any subsoil condition surrounding the bore test holes. For a more accurate
portrayal of subsurface conditions, the site contractor should perform tests
pits. If different conditions are encountered, F.E.T. shall be notified to review
the findings and make any recommendations as needed.
Laboratory and Field Tests
Tests are performed in accordance with specific ASTM Standards unless
otherwise indicated. All criteria included in a given ASTM Standard are not
always required and performed. Each test report indicates the measurements
and determinations actually made.
Ownership of Tests / Reports
All test results and/or reports prepared by F.E.T. pursuant to this agreement
and/or Addendum(s) thereto, shall remain the property of F.E.T. until all
monies due and owing to F.E.T. under this Agreement and/or Addendum(s)
thereto, are paid in full.
Analysis and Recommendations
The Geotechnical report is prepared primarily to aid in the design of site work
and structural foundations. Although the information in the report is expected
to be sufficient for these purposes, it is not intended to determine the cost of
construction or to stand alone as construction specifications.
tedtral
n9 no 'ring
& sting, Inc.
Analysis and Recommendations cont.
In accepting this report the client understands that all data from the soil boring
is intended for foundation analysis only and is not to be used for excavating,
backfilling or pricing estimates. In accepting this report the client understands
that all data from the soil boring is intended for foundation analysis only and
is not to be used for excavating, backfilling or pricing estimates. The site
contractor must familiarize themselves with the job site conditions. Soil
boring(s) on unmarked vacant property or existing structure(s) to be
demolished is considered preliminary withfurther lit4i ,O)to be performed
after proposed building pad is stake&Vijt!R§ort re jomme:dations are 9W
primarily on data from test borings jWg jtrthe Iocrdon wItown on thelast
boring reports. Soil variations mV� SIV, etween borings and may not
become evident until construction. If v•
,Ajjtions are then noted, F.416.at A
be contacted so that field conditions jj%;e examined and recommendations
revised if necessary. The Geotechniell rgpo� states or r un00 derstanding eas�to
the location, dimensions, and structurM, 28tures proposed of the site. airy
significant changes in the nature, dgip ,o� location of the site improvet-644
must be communicated to F.E.J. so rat the Geotechnical analysis,
conclusions, and recommendations can be ipproprialei�•adjutted. 000060
• • • • •
••••
Construction Observations
Construction observation and testing is an important element of Geotechnical
services. The Geotechnical Engineer's Field Representative (Field Rep.) is the
"owner's representative" observing the work of the contractor, performing
tests, and reporting data from such tests and observations. The Geotechnical
Engineer's Field Representative does not direct the contractor's construction
means, methods, operations, or personnel. The Field Rep. does not interfere
with the relationship between the owner and the contractor, and except as an
observer, does not become a substitute owner on site. The Field Rep. is only
collecting data for our Engineer to review. The Field Rep. is responsible for
his/her safety only, but has no responsibility for the safety of other personnel
and/or the general public at the site. If the Field Rep. does not feel that the
site is offering a safe environment for him/her, the Field Rep. will stop his/her
observation/ testing until he/she deems the site is safe. The Field Rep. is an
important member of a team whose responsibility is to observe the test and
work being done and report to the client whether that work is being carried
out in general conformance with the plans and specifications.
Limitations of Report
Federal Engineering & Testing, Inc. shall have no liability, in contract, tort or
otherwise, for any inaccuracy, defect, or omission in interpreting this report
and shall not in any event have any liability for lost profits or any other
indirect, special, incidental, consequential, exemplary or punitive damages. In
the event of future conflict between owners and contractors the following
applies: F.E.T.(s) legal and/or company representation and preparation for
representation fees will be billed on an hourly rate, i.e. deposition, expert
witness, etc. F.E.T. has no obligation to amend its conclusions or
recommendations after the date of this report. Any alterations or changes in
the location of the project should be brought to our attention at the earliest
convenience for review and applicability of this report.
ederal
0 Q ngineering
8� Q esting, Inc.
Soil / Aggregate Tests
Soil Borings
Density Compaction Tests
Grain Size Analysis
Moisture Contents
Soil Classifications
Limerock Bearing Ratios
Florida Bearing Values
Specific Gravity
Carbonate Analysis
Hydraulic Conductivity
Organic Contents
L.A. Abrasion
FDOT Inspections
QC Management
Earthwork Inspections
QC Concrete Inspections
QC Asphalt Inspections
Partial List of Services
Geotechnical Engineering Services
Field Inspection Services
Fill & Quality Control Inspections
Demucking Inspections
Building Inspections
Pile Driving Inspections
Pile Load Tests
Steel Inspection
Threshold Inspection
Bolt Inspection
Weld Inspection
Vibration Monitoring
Geotechnical Engineering
Foundation Engineering
Foundation Design & Recommendation
Subsoil Investigation
Pile Load Calculations
Piling Installation Monitoring
Phone: 954 784.2941
E-Fax: 954-7847875
admin@fed-eng.com
www.fed-eng.com
•. .. 33334
Asphalt Services
Backscatter Density Tests
Extractions & Gradations
Marshall Limits
Bulk Specific Gravity
Cores for Thickness LeItUination
AsphaltPaue'naent Monitoring
• • • • • •
Asphalt A sestment:...;.
•
COncreld'ftts
;,�••�
Concreti'S6'tigth TpSUng,
• •
SlumpTIM* • ••
••�•,•
WindsotT"bt TestitV •
•••..
Schmidt 11dMmer Testing*
•.....
Core TIARV; •
.'
Air CorRent • • .
....:.
Concr Wei Mt
Flexual 3ttength Teltir g•.
:
....
Environmental Engineering Services
Phase I Site Assessments Phase II Site Assessments Lead Base Paint Surveys
Site Inspections Phase I Follow up on Contaminated Sites Report and Analysis
Research of Property Records Installation of Monitoring Wells Air Monitoring
Soil Borings
Soil and Ground Water Analysis
Roof Testing & Inspection Services
TAS 105 Field Fastener Withdrawal Test
TAS 106 Tile Uplift Test
TAS 124 Bell Chamber / Bonded Pull Test
TAS 126 Moisture Survey
Windload Calculation
Drainage Calculations
Lightweight Concrete placement Inspection
Roof Assessment / Evaluation
Cap Sheet Inspection
Fastener Spacing Inspection
Tile/ Shingle/ Standing Seam Inspection
Base Sheet Installation Inspection
Insurance Mitigation
Retrofit Mitigation! Certification
Roof Drainage Calculations
"T'�A>i�nue Oak#at�ci Park Fto `'
r4 :, Mci r ; . MIAMH'MM, Z.
. _'.'..._� '`�✓'- AppmW laboratory �_ ...
KENNETH R. PFEIFFER, P.E.
8754 S,W, 206 LANE
CUTLER BAY, FLORIDA 33189
CONSTANT CALCULATIONS
Concrete Strength = 5000 psi Steel Modulus = 29,000,000 psi
Concrete Modulus, Ec = 4050096 psi v(allowable) = 2V-F1
Ec=57277 * F1 ^.5 n = Es/Ec k= n/(n+(Fs/Fc)) j = 1.00 - k/3
K= Fc*j*k/2 p= k*Fc/(2*Fs) p= k*Fc/(2*Fs) u= 3V-F1
Residential Swimming Pool for
Zetka Residence
1361 N,E. 10 Street
Miami Shores, Florida
Fc = 2250 psi n = 7.2 k = 0.446 j = 0.851 K = 427
•
p = 040251 u = 212 Fy = 60000 psi Fs = 20000 psi v(allow) = 141 psi
. .
....
......
•
INPUT DATA
......
• • • • •
....
..
......
•
--- ---------- ----------------------------- --------------- -----------------------
Pool Depth = 5 feet 6 inches
•
Critical Panel Area = 3 5 square feet
.. ..
• • • • • •
.
......
Drop Panel Area = 4 square feet
'
Maximum Pile Spacing = 6 feet 3 inches
• • • • • •
Minimum Pile Spacing = 5 feet 6 inches
•.
;
.
• �. •;
Slab Cantiliver = 2 feet
•
Wall Thickness = 6 inches
• •
SLAB THICKNESS
--------------------------------------------------------------------------------
Slab Thickness, tl = 1.5 x t2
Slab Thickness t2(Drop Panel) = 0.375 x L x cube root of 2000/171
t 1 = 2.598 t2 = 1.732
Allow 3 inch cover to top and bottom steel in slab. Minimum Slab Thickness = 7.73 inches
8 Inch slab required
Author utilizes a standard slab thickness of 10 inches unless it is
required to be greater by calculations.
Use 10 inch thick slab.
Drop panel thickness shall not be less than 2 inches
Try 6 inch thick panel
PANEL LOAD AND WALL LOAD
W = Wd x 62.4 + Q x 150 / 12
Slab load = 499.4 pounds per square foot
Panel load = Slab load x Panel area
Panel Load = 17479.0
Wall Load = 2812.5
Deck Load = 0
Contributing Wall Load = (Depth of water x wall thickness x 150 #/sq. ft. x length) + any structural deck load
Contributing Wall Load = 2812.5 pounds
Total Panel Load = 20291.5
SHEAR CALCULATIONS
-----------------------------------------------------------------------
Check shear at edges where slab and drop panel join:
Area of whole panel = 35 square feet
Area of drop panel = 4 square feet
Area around drop panel = 31 square feet
Load on slab only = 18293.9 pounds
Assume a depth to steel of 7 v = V/jdb where b = 4 x 2 x 12 = 96 inches
v = 15.66 psi < Allowable shear (110 psi)
Shear at drop panel edge OKAY
Check punching shear at pile
Perimeter of helical plate = 48 inches
Circumberence of failure = 12 + 12*tan(45/(360/(2*3.1416))) = 68.895315
Total Pile Load = 20966.5 pounds
Shear at pile fracture = 39.7209175 psi
Pile shear is okay
MOMENT CALCULATIONS
-------------------------------------------------------------------------------
Mo = 0.09 x PI x L x F(1.00 - 2C/3L)squared
Where L = length between piles f = factor not to be less than 1
C = Diameter of pile in feet and W = Panel load
F = 1.15 - 14/12/L = 0.96333333
--------------------------------------------------------------------------------
The author chooses not to apply any reduction factors in determining
the maximum panel moment
In addition, the author chooses not to determine moments in the minor
direction. The major moments will be applied in it's place
--------------------------------------------------------------------------
......
..
......
....
.
.....
......
. .
.....
.. ..
.
......
. .
. .
......
Total Panel Moment = 0.09 x P1 x L x 1.15 = 11306.7281
Moments as per code shall be proportioned as follows:
Maximum negative moment at 50 percent occuring in strip 1
Maximum positive moment at 20 percent occuring in strip 1
Maximum negative moment at 15 percent occuring in strip 2
Maximum positive moment at 15 percent occuring in strip 2
--------------------------------------------------------------------------------
MOMENT DISTRIBUTION
-Ml = 0.50 x 11306.7281 = 5653.36406 ft.-lbs.
+M 1 = 0.20 x 11306.7281 = 2261.34562 ft.-lbs.
-M2 = 0.15 x 11306.7281 = 1696.00922 ft.-lbs.
+M2 = 0.15 x 11306.7281 = 1696.00922 ft.-lbs.
--------------------------------------------------------------------------------
CALULATE STRIP WIDTHS
Span 1 = 6.25 feet
Span 2 = 5.5 feet
Because the author chooses to use the critical dimensions and apply
them in both directions, the minimum span shall be used.
Strip 1 = Span 2 / 2 and Strip 2 = Span 2 / 4
STRIP I = 33 INCHES
STRIP 2 = 16.5 INCHES
CALCULATE STRIP STEEL AREA
-Asl = 0.569 INCHES
+As 1 = 0.228 INCHES
-As2 = 0.171 INCHES
+As2 = 0.171 INCHES
BAR SPACING
Provide #4 bars at 10 inches TOP
Provide #4 bars at 10 inches BOTTOM
Provide #4 bars at 10 inches TOP
Provide #4 bars at 10 inches BOTTOM
CANTILEVER SLAB CALCULATONS
Maximum Cantilever Moment = 2011.30 foot-pounds
#4 bars at 11 inches TOP
•.••
• •
f1.••
••••.•
......
..
......
....
.
.....
•
•••• .
•
••••••
•
•
• •
• •
••••••
•
• .
•.••••
•• •
. ••
•
. •
r
Area of Steel Required = 0.203 inches
Area Provided = 0.240
UPLIFT CALCULATIONS
Uplift Moment = (Water Displacement - Slab Weight) x Max. Pile Span (squared) / 8
Water Displacement = 374APounds Slab Weight = 124.5 pounds Pile Span = 6.25 feet
Uplift Moment = 14642.5781 inch pounds
Uplift steel required = 0.10
Uplift steel provided = 0.24
WALL CALCULATIONS
Backfill Moment = 0.5734 x 100 x (Wd cubed)
Backfill Moment = 12385 inch -pounds
Water Moment = 2 x 62.4 x (Wd cubed)
Water Moment = 26957 inch -pounds
p = 0.2867 x 1 x 100
]� = 29 psf
�- = 0.2867 x (Wall Height + 1) x 100
= 200.69 psf
H=Wall Height *p+V/2
H = 689 Pounds
y = Wall Height * (0- + 2(0)) / (3 + p~))
y = 2.25 ft.
Wall Moment = H x y x 12
Wall Moment = 18626 inch -pounds
Live Moment = Wall Moment - Backfill Moment
Live Moment = 6240 inch -pounds
Ultimate Moment = 1.7 x Live Moment + 1.4 x Dead Moment
Ultimate Moment = 1.7 x 6240 + 1.4 x 12385
Ultimate Moment = 27948 inch -pounds
Wall Steel Area per foot = Ultimate Moment / (0.9 * Fy * (Wall thickness / 2))
Minimum Wall Steel Area per foot = 0.17251867
Use #3 bars at 7 inches (0.18857143 inches
. .
....
......
....
. .
......
.
......
. .
.....
.. ..
.
......
......
.
.
. .
. .
......
.
.
. .
. .
.....•
.. .
. ..
.. .
16"� 'tic�, 9
t..
Ordered By:
Rothman
&T bin
T
BISCAYNE DRAINAGE CANAL
CORNER
(-75.00' (P) EDW OF WA7rR
CORNER
W WATER
-
___--— 1,30' SEA wA
IN w.ATfR
WOODDECKF.Aw
150"
7&00* -
(M)
-o
F.NA/L10.
,�
,••r
CONC LOT 2
• •' •
ri .113.0• BLOCK 3
, , ... •
"
C%
C
4' CNIj1{I.WK• •
'
Y I
p 7.40'
♦ , h
FENCE
• • r ,
• •
f • • f • •
42.0' M' O
• • •
g WOOD n.,_
DECK 20.0,
„a•••
• •
•••••
•
t10'
0.30'
.00`
24.40'
o,
come
�• • •
•
o
CONC Z 13.0-c4 '
2
•
ena 3.3.00'
it1.b(l'�
,
• • �
• •
BLOCK 3 �'
8
cio
411
� LOT 3
p
0
TWO
3
h
,F1
STORY
C' •
BLOCK 3
RESIDENCE
p
O
...
3.
VIP
,�
27.00'
AC
t 0.00'
PORCH 5
DECK =
-..
ri 29.00'
40 21.70'
11.50' CONC
DRIVE
o
ch
75.00' (P)
20.40'
B.C.F.1.P.
112"
F.I.P. 112" /2V
4
(NO. ID.) (NO. !D.)
(NO. 1Q.)
3
I PARKWAY
0
50' R1GNT-OF-WAY (8Y PUT)
20'f ASPHALT PAVEmrw
N.E. 1 Q4th STREET
Accepted Ry.
Prop" Address: Notes: WOOD DECK ENCROACHES QVF.R NORTH LOT
1361 N.E. 104 Street LINE. FENCES ENCROACH OVER WEST LOT LINE.
Miami Shores, FLORICA :,3136
QMum 111C C�A_nrN TMAr7WS RY8A*YisATRMAM M.E. Land Surve m Inc. .
TFTi'aFi OFM ftAutTB1 MYUMta:TOer. i>.ffiCpihEE y �•
WrtH TMEMNIMUY T[Ci7Mt,` "s.-.. CRTN•r THE=TECFnX)l DA9WDof 10665 SW iJOth Street
PROF�SIDNKUND FUR` 'f+N't.=.°-rTi" T!iRgrOM bJ 71-D�F4ARDA
ApA•pSrRATNECCDE PL `a4? _ A'!,*s Suite 3110
SIGNED �y�� ' FOR THE FIRM Miami, FL 33157 `fit
EFRAIN LOP c,. Phone: (305) 740-3319 i
STATE OF FL ii� P.S.M. No. $792 Fax: (305) 669-3190 m
nor vAw wrrHauT Arro Au*. srwruRE.0 AUTM_V.�...TM LIN: 79a9
FiEECCrnaeacsr�twD+0RTM5w�Ps w DwttMaurTMESMATunErvQTHE ORgr+n_
RAWD SEALOF AUDMOM Mi AND AMAMW
St—, a B-4662; Cli 9R File qt 19-221
Page 1 of I V.n alid without all nave,
Miami shores Village
Building Department
RFCFIAT
PERM i I #: �� �� � � � �� W (r DA I M.
(Name)
Contras or
weer
,—! Architect
10050 N.E.2nd Avenue
Miami Shores; Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
1) h(a I 19
Picked up 2 sets of plans and (other)
Address:
=rom the building department on this date in order to have corrections done to plans
And/or get County stamps. 1 understand that the plans need to be brought back to Miami
Shores Village Building Depar`rrient to continue permitng process.
Signature:
PERMIT CLERK INITIAL
RESUBMITTED DATE:
PERMIT CLERK WITL4
ATURE)
full ,
SNORES �,
e."
PERMIT ADDRESS:
1361 NE 104TH ST
Miami Shores, FL 33138
APPLICATION DATE:
07/11/2019 SQUARE FEET:
EXPIRATION DATE:
01/07/2020 VALUATION:
CONTACTS
NAME
Contractor
JORGE LUIS GARCIA
JORGE LUIS GARCIA
Owner ERIC ZETKA
ERIC ZETKA
PARCEL: 1122320320020
1,450.00 DESCRIPTION:
NEW POOL & DECK
$70,000.00
COMPANY
ADDRESS
DESIGNER POOLS INC
13330 SW 205 LN
MIAMI, FL 33177
DESIGNER POOLS INC
, FL
260 NE 99 ST
MIAMI SHORES, FL 33138
260 NE 99 ST
MIAMI SHORES, FL 33138
REVIEW ITEM STATUS REVIEWER
Building v.1 Requires Re -submit Ismael Naranjo email: naranjoi@msvfl.gov
Review item used to allow building to comment during a plan review
Comments: 1. Zoning and structural approval require.
2. Provide geotechnical soil investigation and recommendations for pile foundation. 1803
3. Provide detail, itemize job cost estimate for the entire project, including pile foundation.
Electrical v.1 Approved CARLOS SOSA email: EL@MSVFL.GOV
Planning v.1 Requires Re -submit Travis Kendall email: kendallt@msvfl.gov
Review conducted by the planning and zoning department
Comments: Pool side setback must be a minimum of 12.5 feet from the property line. In addition pool equipment must be a minimum of ten feet from
the side property line and five feet from the rear please indicate all setbacks for proposed equipment.
Plumbing v.1 Approved Maykel Massanet email: pl@msvfl.gov
Structural v.1
Requires Re -submit Orlando Blanco email: null16
Comments: 1. PROVIDE TWO COPIES OF SPECIAL INSPECTOR FORM, FULLY EXECUTED FOR:
A) MIAMI DADE COUNTY ADMINISTRATIVE CODE, ARTICLE II, SECTION 8-22
1) PILE FOUNDATIONS
2) SOIL COMPACTION
(REFER TO ATTACHED COPY OF THE INSPECTION FORM)
ADDITIONAL COMMENTS MAYBE PENDING AFTER REVIEW OF THE REQUESTED DOCUMENTS LISTED ABOVE
November 01, 2019 10050 NE 2 Ave Miami Shores FL 33138 Page 1 of 1
Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
RECEIPT
PERMIT #: 0 I I '\�nATE:
(Name)
'Contractor
❑ Owner
❑ Architect
Picked up 2 sets of plans and (other) 14y `� J
�j
Address: I�0 i NE ��_ 1�
From the building department on this date in order to have corrections done to plans
And/or get County stamps. I understand that the plans need to be brought back to Miami
Shores Village Building Department to continue permitting process.
Signature:
GNATURE)
PERMIT CLERK INITIA
RESUBMITTED DATE:
PERMIT CLERK INITIAL:
�gORES Miami Shores Village
Building Department
10050 NE 2"d Ave.
F- Miami Shores, FL 33138
305-795-2204 / Fax 305-756-8972
STRUCTURAL REVIEWS COMMENTS - AS OF 10/22/19
Permit No.: BPP19-1602
Project Address: 1361 NE 104T" ST.
Page 1 of I
2ND REVIEW AS OF 12/5/19
ITEM NO. 1, AS LISTED BELOW, IS STILL PENDING
1. PROVIDE TWO COPIES OF SPECIAL INSPECTOR FORM, FULLY EXECUTED
FOR:
A) MIAMI DADE COUNTY ADMINISTRATIVE CODE, ARTICLE II,
SECTION 8-22
1) PILE FOUNDATIONS
2) SOIL COMPACTION
(REFER TO ATTACHED COPY OF THE INSPECTION FORM)
ADDITIONAL COMMENTS MAYBE PENDING AFTER REVIEW OF THE
REQUESTED DOCUMENTS LISTED ABOVE
Miami Shores Village
Building Department
10050 NE 2nd Ave.
F�a 1 Miami Shores, FL 33138
305-795-2204 / Fax 305-756-8972
NOTICE TO MIAMI SHORES BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL
INSPECTOR UNDER THE FLORIDA BUILDING CODE.
I (We) have been retained by to perform special inspector services under the Florida
Building Code 6ch Edition (2017) and Miami Dade County Administrative Code at the
project on the below listed structure as of (date). I am a registered
architect/professional engineer licensed in the State of Florida.
Process Number: AV- ) r 14411
Special Inspector for Reinforced Masonry, Section 2122.4 of the FBC 6ch Edition (2017)
"Miami Dade County Administrative Code, Article II Section 8-22 Special Inspectorfor
_ Trusses > 35 ft. long or 6 ft. high
Steel Framing and Connections welded or bolted
+Soil Compaction
Precast Attachments
Roofing Applications, Lt. Weight. Insul.Conc.a ✓Other e �d✓�!/n
Note: Only the marked boxes apply.
The following individual(s) employed by this firm or me is authorized representative to perform
inspection*
1. 2.
3. 4.
*Special inspectors utilizing authorized representatives shall insure the authorized representative is qualified by
education or licensure to perform the duties assign by Special Inspector. The qualifications shall include licensure as a
professional engineer or architect: graduation from an engineering education program in civil or structural engineering;
graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination;
or registration as building inspector or general contractor.
I (we) will notify the Miami Shores Building Department of any changes regarding authorized personnel
performing inspection services.
I (we), understand that a Special Inspector inspection log for each building must be displayed in a
convenient location on the site for reference by the Miami Shores Building Department Inspector. All
mandatory inspections, as required by the Florida Building Code, must be performed by the Miami Shores
Building Department .Inspections performed by the Special Inspector hired by the owner are in addition to
the mandatory inspections performed by the department. Further, upon completion of work under each
Building Permit, I will submit to the Building Inspector at the time of the final inspection the completed
inspection log form and a sealed statement indicating that, to the best of my knowledge, belief and
professional judgment those portions of the project outlined above meet the intent of the Florida Building
Code and are in substantial accordance with the approval plans.
Engineer/Architect
Name
Signed and Sealed Print
Date: Address
Miami Shores Village
Building Department
u,
10050 NE 2"d Ave.
Miami Shores, FL 33138
305-795-2204 / Fax 305-756-8972
STRUCTURAL REVIEWS COMMENTS - AS OF 10/22/19
Permit No.: BPP19-1602
Project Address: 1361 NE 104T" ST.
Page 1 of 1
2ND REVIEW AS OF 12/5/19
ITEM NO. 1, AS LISTED BELOW, IS STILL PENDING
1. PROVIDE TWO COPIES OF SPECIAL INSPECTOR FORM, FULLY EXECUTED
FOR:
A) MIAMI DADE COUNTY ADMINISTRATIVE CODE, ARTICLE II,
SECTION 8-22
1) PILE FOUNDATIONS
2) SOIL COMPACTION
(REFER TO ATTACHED COPY OF THE INSPECTION FORM)
ADDITIONAL COMMENTS MAYBE PENDING AFTER REVIEW OF THE
REQUESTED DOCUMENTS LISTED ABOVE
Miami Shores Village
,NoAs
Building Department
x.r.�
10050 NE 2"d Ave.
Fca'iiiflA
Miami Shores, FL 33138
305-795-2204 / Fax 305-756-8972
NOTICE TO MIAMI SHORES BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL
INSPECTOR UNDER THE FLORIDA BUILDING CODE.
I (We) have been retained by to perform special inspector services under the Florida
Building Code gch Edition (2017) and Miami Dade County Administrative Code at the
project on the below listed structure as of (date). I am a registered
architect/professional engineer licensed in the State of Florida.
Process Number: �(" 6 1.,
Special Inspector for Reinforced Masonry, Section 2122.4 of the FBC 6ch Edition (2017)
Miami Dade County Administrative Code, Article II Section 8-22 Special Inspector for
Trusses > 35 ft. long or 6 ft. high
Steel Framing and Connections welded or bolted
L, oil Compaction
Precast Attachments
Roofing Applications, Lt. Weight. Insul.Conc.
Note: Only the marked boxes apply.
The following individual(s) employed by this firm or me is authorized representative to perform
inspection*
1. 2.
3. 4.
*Special inspectors utilizing authorized representatives shall insure the authorized representative is qualified by
education or licensure to perform the duties assign by Special Inspector. The qualifications shall include licensure as a
professional engineer or architect: graduation from an engineering education program in civil or structural engineering;
graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination;
or registration as building inspector or general contractor.
I (we) will notify the Miami Shores Building Department of any changes regarding authorized personnel
performing inspection services.
I (we), understand that a Special Inspector inspection log for each building must be displayed in a
convenient location on the site for reference by the Miami Shores Building Department Inspector. All
mandatory inspections, as required by the Florida Building Code, must be performed by the Miami Shores
Building Department .Inspections performed by the Special Inspector hired by the owner are in addition to
the mandatory inspections performed by the department. Further, upon completion of work under each
Building Permit, I will submit to the Building Inspector at the time of the final inspection the completed
inspection log form and a sealed statement indicating that, to the best of my knowledge, belief and
professional judgment those portions of the project outlined above meet the intent of the Florida Building
Code and are in substantial accordance with the approval plans.
Engineer/Architect
Name
Signed and Sealed Print
Date: Address
SORES
fIO RIV
PERMIT ADDRESS: 1361 NE 104TH ST
Miami Shores, FL 33138
APPLICATION DATE: 07/11/2019 SQUARE FEET:
EXPIRATION DATE: 01/07/2020 VALUATION:
CONTACTS NAME
Contractor JORGE LUIS GARCIA
Owner
JORGE LUIS GARCIA
ERIC ZETKA
ERIC ZETKA
PARCEL: 1122320320020
1,450.00 DESCRIPTION: NEW POOL & DECK
$70,000.00
COMPANY
DESIGNER POOLS INC
DESIGNER POOLS INC
ADDRESS
13330 SW 205 LN
MIAMI. FL 33177
, FL
260 NE 99 ST
MIAMI SHORES, FL 33138
260 NE 99 ST
MIAMI SHORES, FL 33138
REVIEW ITEM STATUS REVIEWER
Building v.1 Requires Re -submit Ismael Naranjo email: naranjoi@msvfl.go
Review item used to allow building to comment during a plan review
k'.
Comments: 1. Zoning and structural approval require.
2. Provide geotechnical soil investigation and recommendations for pile foundation. 1803`I
3. Provide detail, itemize job cost estimate for the entire project, including pile foundation.
Building v.2 Requires Re -submit Ismael Naranjo email: naranjoi@msvfl.gov
Review item used to allow building to comment during a plan review
Comments: 1. Structural approval require.
Electrical v.1
Approved CARLOS SOSA email: EL@MSVFL.GOV
Planning v.1 Requires Re -submit Travis Kendall email: kendallt@msvfl.gov
Review conducted by the planning and zoning department
Comments: Pool side setback must be a minimum of 12.5 feet from the property line. In addition pool equipment must be a minimum of ten feet from
the side property line and five feet from the rear please indicate all setbacks for proposed equipment.
Planning v.2 Approved Travis Kendall email: kendallt@msvfl.gov
Review conducted by the planning and zoning department
Plumbing v.1
Structural v.1
Approved Maykel Massanet email: pl@msvfl.gov
Requires Re -submit Orlando Blanco email: null16
Comments: 1. PROVIDE TWO COPIES OF SPECIAL INSPECTOR FORM, FULLY EXECUTED FOR:
A) MIAMI DADE COUNTY ADMINISTRATIVE CODE, ARTICLE II, SECTION 8-22
1) PILE FOUNDATIONS
2) SOIL COMPACTION
(REFER TO ATTACHED COPY OF THE INSPECTION FORM)
ADDITIONAL COMMENTS MAYBE PENDING AFTER REVIEW OF THE REQUESTED DOCUMENTS LISTED ABOVE
Structural v.2 Requires Re -submit Orlando Blanco email: nu1116
Comments: 2ND REVIEW AS OF 12/5/19
ITEM NO.1, AS LISTED BELOW, IS STILL PENDING
-----------------------------------------------
-----------------------------------------------
1. PROVIDE TWO COPIES OF SPECIAL INSPECTOR FORM, FULLY EXECUTED FOR:
A) MIAMI DADE COUNTY ADMINISTRATIVE CODE, ARTICLE II, SECTION 8-22
1) PILE FOUNDATIONS
2) SOIL COMPACTION
December 09, 2019 10050 NE 2 Ave Miami Shores FL 33138
Page 1 of 2
(REFER TO ATTACHED COPY OF THE INSPECTION FORM)
ADDITIONAL COMMENTS MAYBE PENDING AFTER REVIEW OF THE REQUESTED DOCUMENTS LISTED ABOVE
December 09, 2019 10050 NE 2 Ave Miami Shores FL 33138 Page 2 of 2
1
`SNS. ORES ti
<<7
�h7pg,N
F�ORIOQ'
PERMIT ADDRESS: 1361 NE 104TH ST PARCEL: 1122320320020
Miami Shores, FL 33138
APPLICATION DATE: 07/11/2019 SQUARE FEET: 1,450.00 DESCRIPTION: NEW POOL & DECK
EXPIRATION DATE: 01/07/2020 VALUATION: $70,000.00
CONTACTS NAME COMPANY ADDRESS
Contractor JORGE LUIS GARCIA DESIGNER POOLS INC 13330 SW 205 LN
MIAMI, FL 33177
Owner
JORGE LUIS GARCIA
ERIC ZETKA
ERIC ZETKA
DESIGNER POOLS INC
, FL
260 NE 99 ST
MIAMI SHORES, FL 33138
260 NE 99 ST
MIAMI SHORES, FL 33138
REVIEW ITEM STATUS REVIEWER
Building v.1 Requires Re -submit Ismael Naranjo email: naranjoi@msvfl.gov
Review item used to allow building to comment during a plan review
Comments: 1. Zoning and structural approval require.
2. Provide geotechnical soil investigation and recommendations for pile foundation. 1803
3. Provide detail, itemize job cost estimate for the entire project, including pile foundation.
Building v.2 Requires Re -submit Ismael Naranjo email: naranjoi@msvfl.gov
Review item used to allow building to comment during a plan review
Comments: 1. Structural approval require.
Electrical v.1
Approved CARLOS SOSA email: EL@MSVFL.GOV
Planning v.1 Requires Re -submit Travis Kendall email: kendallt@msvfl.gov
Review conducted by the planning and zoning department
Comments: Pool side setback must be a minimum of 12.5 feet from the property line. In addition pool equipment must be a minimum of ten feet from
the side property line and five feet from the rear please indicate all setbacks for proposed equipment.
Planning v.2 Approved Travis Kendall email: kendallt@msvfl.gov
Review conducted by the planning and zoning department
Plumbing v.1
Structural v.1
Approved Maykel Massanet email: pl@msvfl.gov
Requires Re -submit Orlando Blanco email: null16
Comments: 1. PROVIDE TWO COPIES OF SPECIAL INSPECTOR FORM, FULLY EXECUTED FOR:
A) MIAMI DADE COUNTY ADMINISTRATIVE CODE, ARTICLE II, SECTION 8-22
1) PILE FOUNDATIONS
2) SOIL COMPACTION
(REFER TO ATTACHED COPY OF THE INSPECTION FORM)
ADDITIONAL COMMENTS MAYBE PENDING AFTER REVIEW OF THE REQUESTED DOCUMENTS LISTED ABOVE
Structural v.2 Requires Re -submit Orlando Blanco email: null16
Comments: 2ND REVIEW AS OF 12/5/19
ITEM NOA, AS LISTED BELOW, IS STILL PENDING
-----------------------------------------------
-----------------------------------------------
1. PROVIDE TWO COPIES OF SPECIAL INSPECTOR FORM, FULLY EXECUTED FOR:
A) MIAMI DADE COUNTY ADMINISTRATIVE CODE, ARTICLE Il, SECTION 8-22
1) PILE FOUNDATIONS
2) SOIL COMPACTION
December 09, 2019 10050 NE 2 Ave Miami Shores FL 33138
Page 1 of 2
(REFER TO ATTACHED COPY OF THE INSPECTION FORM)
ADDITIONAL COMMENTS MAYBE PENDING AFTER REVIEW OF THE REQUESTED DOCUMENTS LISTED ABOVE
December 09, 2019
10050 NE 2 Ave Miami Shores FL 33138 Page 2 of 2
EAsrcOAST TESTING & ENGINEERING, INC.
1900 NW 33rd Street - Bay #4 4361 Okeechobee Blvd. - Suite A-5
Pompano Beach, Florida 33064 West Palm Beach, Florida 33409
Broward (954) 972.7645 (SOIL) (954).972.SOIL
FACSIMILE #954-971-8872
ESTABLISHED 1981 ETE@BELLSOUTH.NET
S pp-c�-1 -- (c, - , UO2
February 03, 2020
Florida Foundation Systems, Inc.
2030 NW 22nd Court
Pompano Beach, Florida 33069
Re: Certification of Helical Piers at: 1361 NE 104 Street
Miami Shores, Florida
Proposed Pool - Foundation/Stabilization
To Whom it May Concern;
In accordance with Chapter 18, Section 1809.2 of the 2017 Florida Building Code, 6`h Edition, we
wish to offer Florida Foundation Systems, Inc., and the City of Miami Shores Building Department,
the following statement with respect to the disposition of the Helical Piers, (Piling) installation.
"To the best of my knowledge and ability, the fifteen, (15) Helical Piers, (Piling) were installed in
general accordance with the approved permitted plans, and project specifications". These piling will
provide an allowable compressive capacity of 24 kips, (12.0 tons). The date of this installation was
on January 21, and January 22, 2020.
Thank you for allowing us to be of service to you in this matter. If we can be of any further
assistance, please do not hesitate to contact our office.
Respectfully Submitted,
EASTCOAST TESTING AND ENGINEERING, INC.
Certificate of Authorization
3425 \`\\\N%IAMM1,,
0�i
Mohammed A. Hai, P.E. \ tr. 4ICEIV alk
"U%'Smith, President
Senior Geotechnical Engineer
Florida Registration No. 5934i * No 59345
wpdocs\cscores\7200112.0113.cert.ffsy,;ih. ~
,r STATE OF
I Nq L t.ENG, \
111
THRESHOLDISPECIAL INSPECTIONS BORINGS DENSITY CONCRETE, ASPHALT, ETC. A "GEOTECHNICAL TESTING LAB"
EASTCOAST TESTING & ENGINEERING, INC.
1900 NW 33rd Street - Bay #4
Pompano Beach, Florida 33064
4361 Okeechobee Blvd. - Suite A-5
West Palm Beach, Florida 33409
Broward (954) 972.7645 (SOIL) (954).972.SO1L
FACSIMILE #954-971-8872
ESTABLISHED 1981 ETEi�?BELLSOUTH.NET
HELICAL PIER LOG
LAB NUMBER: 7200113 s --
CLIENT: FLORIDA FOUNDATIONS SYSTEMS, LLC. DAY: WEDNESDAY
PROJECT: ZETKA RESIDENCE - PROPOSED (NEW) SWIMMING POOL DATE: 01.22.2020
ADDRESS: 136' NE '04 STREET MIAMI SHORES FLORIDA
PILE CONTRACTOR, FLORIDA FOUNDATIONS SYSTEMS, LLC. FOLIO No. 11-2232.032-0020
LOCATION: SWIMMING POOL FOUNDATION -STABILIZATION BORINGS: FEDERAL ENG.
INSPECTOR: C. SMITH NsrnL:_ano J oav x2 2
I
ENGINEER: MOHAMMED A. HAI, P.E FL. REG No 59345
Order
Installed
PILING DESIGNATION I
HELICAL PIER LOCATIONS
PIER
"TYPE" i
Specified PSI
Installed PSI
Pier
Depth Ft.
Design Capacity
Required: CIT KIPS
Installed
CIT (KIPS)
DIAL McDANIEL
DIAL McDANIEL
8th_'POOL:
PLAN PIER #08 1
PEW 2.575x.276
1220 2
REFUSAL
24'
24
24
9th
POOL: PLAN PIER #09
PEW 2.875x.276
1220 2
REFUSAL
43.5'
24
24
loth
POOL: PLAN PIER #12
PEW 2.875x.276
1220 2
REFUSAL
43.5'
24
24
11th
POOL: PLAN PIER #11
PEW 2.875x.276
1220 2
REFUSAL
49'
24
24
12th
POOL: PLAN PIER #13
PEW 2.875x.276
1220 2
REFUSAL
28'
24
24
13th
POOL: PLAN PIER #10
PEW 2.875x.276
1220 2
REFUSAL
28'
24
24
14th
POOL: PLAN PIER #14
PEW 2.875x.276
1220 2
REFUSAL
30'
24
24
15th
POOL: PLAN PIER 015
PEW 2.875x276
1220 2
REFUSAL
43.5'
24
_
24
I
REMARKS:
SWIMMING POOL FOUNDATION STABILIZATION
15115 Helical Piers COMPLETED
Helical Pier: PEW 2.875x.276
Lead / Flights: 12".14"
Installing Equipment: TB-240
Gear Motor: Eskridge 2-Speed 12K
Dial Indicator: McDaniel
i
DESIGN CAPACITY- 24 KIPS 1 12 TONS
T
_ _
1Conclusion: i
'i All Completed Piers installed in accordance with project specifications & manufacturer's recommendations provided.
N 1
RESPECTFULLY SUBMITTED,
EASTCOAST TESTING & ENGINEERIN\QQ% Mp4��I���
CERTIFICATE OF AUTHORIZATION #3425 \�� 0 . • O c ��
CEIV
2/2/2020 ~ * NO S934S
MOHAMMED A. HAI, P.E.
SENIOR GEOTECHNICAL ENGINEER
FLORIDA REGISTRATION No. 59345 Q� STATE OF
'*<DltIDA
Time In. 10:30 AM
Time Out:
03.00 PM
Travel (Hrs.)
2.0 Hrs.
Total Time-.
6.5 Hrs.
CRAIG SMITH, PRESIDENT
"GEO