BPP-07-19-1602, 1361 NE 104th St (2)10/23/2020
Mail - Eric Scott Zetka - Outlook
Print Cancel
Updated survey for permit BPP-07-
19-1602
Eric Scott Zetka <szetka@hotmail.com>
Tue 10/20/2020 3:32 PM
To: Alvarers@msvfl.gov <Alvarers@msvfl.gov>
Cc: gregrpalmer@ymail.com
<gregrpalmer@ymail.com>;
info.designerpools@gmail.com
<info.designerpools@gmail.com>
0 2 attachments Q MB)
21051-S.pdf; ATT00001.htm;
Hello,
Please see the Updated survey for permit
BPP-07-19-1602 (pool). We would like
to schedule the final approval.
Thank you,
Eric Zetka
'5o S--- -7 V I - / V 3 V
https://outlook.live. com/mai 1/0/search/id/AQQkADAwATExADY5NyOOYzMwLTJhN2UtMDACLTAwCgAQAEI Qw8vRvppHhOugmrMiW NO%3D/sxs/AQM... 1 /1
DECEIVED
. .... . . ....
.... . ...... .
... . ..... .
. ....... ....
�`.:�
•• ••J3ISC4f1JE
INA��•C I�I�/�L
• •
• • (70 TOTAL R/W4bF CANAL • •
-
0 10 20
♦ •
�,�•
•
•
• • • • •
Bch- • ••• ••• •
-
SCALE: I' = 20'
True Corner
in Water
LIFT EAST 75. 00'
89'43'10"E 75.00'(M)
True Corn
in water
Found
i-'
•
•'• .-•....
„{
g •.- Found
,�I,t/
V
Drill Hole
�j
'�
•
-, -• 3 t='.•-. i ==•-i •�-.-. ?k = 1l Drill Hole
♦ • • • • • •Survey Tie Lir@
1
t.
Apo
i
'�.. 1.0'WEsi
�5'
30.01
'T POOL
4
TILE0.
2
yA0
Q
TLL N
O
^
a
ZD UI
U y O
H 53.0'
_
__ IX
3
Q
rn
j-
01
- W
Two Story Building
W w -
1=- =
No.1361
U' F 3
IY 1r) t-
o Z r,
s
x its
FF FLEW 5.46'
NISI HIGHER FLOOR ELev. 10.30.
N - F"
0
,
O LO
_
27.0'
-
GARAGE
I I
I O _
PaRSH F
ELm = 5.£4'
9.77
I fn I
-
�{-
Z
f
t Till
U0
i
CONCRETE '
((7 / DRIVEWAY
Found}4 A 1 1 R a
Iron Pipe
_ __. _____ _ __
11489"55'47"W 75.15-(M)
11.6 Parkway
Found Yl"
A A Iran Pipe
A Found Y" 1,189'55'45' E 74.72'(M) @SE Corner of
Iron Reber N90"00'00"F 7500'(R) OLut 3 Block 3
/
N.E. 104T" STREET
50' Taal fGW (Par Plat Gpok 40-Page 72) .p
18.5 Asphalt Pavement
2 3 2020
LEGAL DE§CRIPTION:
Lot 2, Block 3, RIVER -BAY PARK ADDITION. according to the plat thereof, as recorded in
Plat Book 40, Page 72. of the Public Records of Miami -Dade County, Florida.
SURVEYOR'S REPORT AND GENERAL NOTES
(Not valid without the attached Survey Map)
1. Legal Description has been furnished by the client.
2. References to 'Dead", "Record" or 'Plat" refer to documents and instruments of record as
part of the pertinent Information used for this survey work. Measured distances, directions
and angles along boundary litres are in consistency with corresponding values from
records, unless otherwise shown.
3. These lands are subject to additional restrictions of record that were hot furnished to the
undersigning registered surveyor. A title search has not been performed by the surveyor.
4. North arrow direction is based on an assumed Meridian. Bearings are based on an
assumed meridian on a well -established line, said line is being noted as BR on the Survey
Map.
5. Only above ground improvements are shown herein. Foundations, underground features
and utilities have not been located.
6. Survey markers found in the field have no identification unless otherwise shown. Any
survey marker set by our company is labeled LB 7262 or PSM 6169.
7. Fence ownership has not been determined. Distances from existing fences to boundary
lines are approximate. Fencelwalls width and conditions must be considered to determine
true location. Lands located beyond perimeter fences might or might not be being used by
adjumers. Adjoining parcels have not been investigated.
8. This Survey Map is intended to be displayed at the scale shown hereon. Data is expressed
in U.S. Survey Foot.
9. This Survey Map is being prepared for the use of the party/parties that it is certified to and
does not extend to any unnamed individual, entity or assignee.
10.11FLOODPLAIN INFORMATION: As scaled from Federal Insurance Rate Map (FIRM) of
Community No. 120652 (Village of Miami Shores), Panel 0306, Suffix L, revised on Sept
I lth, 2009, this real property falls In Zone "AE" with Base Flood Elevation 8 feet (NGVD
1929)
11.HORIZONTAL ACCURACY: Accuracy obtained thru measurements and calculations
meets and exceeds the minimum horizontal feature accuracy for a Suburban area being
equal to 1 toot in 7, 500 feet.
12.VERTICAL CONTROL AND ACCURACY: The elevations as shown are referred to the
National Geodetic Vertical Datum of 1929 (NGVD 1929). The closure in feet, as computed,
meets the standard of plus or minus 0,05 feet times the squared root of the loop distance in
miles. Elevation are based on a level loop from and to the following official Bench Marks:
Bench Mark # 1: Miami -Dade County Public Works Department Bench Mark B-26-RA,
Elevation = 17.23 feet
Bench Mark # 2: Miami -Dade County Public Works Department Bench Mark B 400,
Elevation = 8.28 feet
m N
(D
_Z n s
LL
co
W --I
Q - N
I HEREBY CERTIFY TO:
uri m
- o
Gregory Richards Palmer and Eric Scott Zetka.
That this Survey conforms to the Standards of Practice as set forth by the Florida Board of
n W
Professional Surveyors and Mappers in applicable provisions of chapter SJ-17. Florida
re
ZQ,
administrative code pursuant to Section 472.027 Florida Statutes. This Survey is accurate and
F
correct to the best of my knowledge and belief.
J
Digitally signed
/ - LL E
by Odalys C Bello
-r to v
Date:2020.10.16
16:32:20 -04'00'
Ct? ¢ m m
Odalys C. Beflo-lznaga
oo rrer
Professional Surveyor and Mapper LS6169 Slate of Florida
ui o
Field Work Date: 10/08/2020
, h m Z
J o m
LL; N L E
Additions and dolnlbns to this Survey Map am prohibited. This survey Map and Report Nip net
Yet M without the signature am original raised seal or without the authenticated loot onk
signaluro omit seol of Ihu u Morsign rag FIuMa II rased survoyorand Mapper
MAP OF BOUNDARY SURVEY
Properly Address:
1361 N.E. 104th Street, Miami Shores, Florida 33138 /
Project No. 21051 Paae 1 of 1