Engineer Letter RC-10-23-2624DEOTEQSNI I ENVIRONMEN•rAL I HATERW TE Wo IAEEEST0 IRO rTE HGI IDRIL3NDBERYICEE RM! C DYNATECH ENGINEERING CORP. / W WW.DYNATECHENGINEERING.COM MOISTURE -DENSITY RELATIONS OF SOILS PROCTOR COMPACTION TEST DATE: July 8, 2025 CLIENT: ROI CONSTRUCTION, LLC. PROJECT: Proposed Addition ADDRESS: 1097 NE 98 Street Miami Shores, FL CONTRACTOR: ROI CONSTRUCTION, LLC. MATERIAL DESCRIPTION: Tan sand with rock fragments SAMPLED BY: WD TESTED BY: WD TEST RESULTS Sample Number 2 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 Ib. Hammer and an 18" drop ASTM D-1557. % MOISTURE 3.9 5.9 6.7 11.0 117C4=11 D ►` 111-61 Optimum Moisture 8.4 Percent 100%Max imum Dry Density 114.6 lbs. cu.ti. °a Passing '6- Sieve 85% PCrCCilt Sampled By: WD Tested By WD Checked By: WN 108.1 111.9 113.1 112.9 As a nunual protmtion to clients. the public and ourselves, all rep<ats 116 114 112 110 108 106 104 4 6 8 Ill 12 14 `P SAAD gq tN, Respectively submitted, `3�c`4:'�\CENgf..fj9ys l0ISsQv✓� * ; No. 39584 ; s D R Y D E N S I T Y v -,%- 1 osorao LAICAL I ErvmoN.Zt:wt l MATERIALS rasrwa l wsseeroa t poor resraaa l aasnacnOH svmcee l awu wo ssnrtcee c DYNATECH ENGINEERING CORP. FIELD DENSITY TEST OF COMPACTED SOILS DATE: July 8, 2025 CLIENT: ROI CONSTRUCTION, LLC. PROJECT: Proposed Addition ADDRESS: 1097 NE 98 Street Miami Shores, FL CONTRACTOR: ROI CONSTRUCTION, LLC. Test No. 4 Location: East side of addition underslab Test No. 5 Location: Center of addition underslab Test No. 6 Location: West side of addition underslab Test No. 7 Location: North side of garage encloser underslab Test No. 8 Location: South side of garage encloser underslab Description of Material: Tan sand with rock fragments TEST NO. 4 5 6 7 8 DEPTH 12" 12" 12" 12" 12" FIELD DENSITY 113.9 112.8 113.2 112.6 113.5 MOISTURE CONTENT % 7..8 6.7 7.1 6.4 7.3 MAX. DENSITY IN THE FIELD % 99.4 98.4 98.8 98.3 99.0 COMPACTION REQUIREMENTS % OF MAXIMUM 98% 98% 98% 98% 98% 100% MAXIMUM DENSITY (LAB) 114.6 114.6 114.6 114.6 114.6 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS * Please note this is not a pad certification. A soil boring must be performed to determine subsoil conditions below the tested compaction layer prior to construction. %0%%tWnnrgrj , ��.�P� SAAD �i q . Respectfully submitted, * ; No. 39584 ' :�Vissam Naamani, P.E. * -9DYNATECH ENGINEERING CORP. ,p i. STATE OF :XQ-Florida Reg. No. 39584 •��'' Certificate of Authorization No.: CA 5491 Tested By: WDChecked By: WN ��''�F`?�3�/OIVpl.F�G`` \