Loading...
Tropical Chevrolet, 05-17-23 UES No 353400 SPECIAL insp rept #024 (footings) - GDZProject No.: 2110.2100049 Report No.: 353400 Date: May 17, 2023 8050 NW 77th Court · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 STRUCTURAL OBSERVATION REPORT No. SPECIAL-024 CN: GDZ Page 1 of 4 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H-18.11, Chapter 471, Florida Statute Client: Lebolo Construction Management, Inc. 2100 Corporate Drive Boynton Beach, FL 33426 Project: Tropical Chevrolet Renovation/Expansion 8880 Biscayne Blvd. Miami Shores, FL 33138 Agent: Gaetano Di Zio, E.I. Date of Services: 05/17/2023 Village of Miami Shores Building Permit No: CC-12-20-2951 (issued date 11/07/22, expires 05/08/23) Scope of Field Services: Professional observation of completed structural elements (Special Inspector). Reference Documents: • JSG structural drawings sheets S1.0 thru S4.2 (15 pages), Bulleting 7 dated 07/21/2022, signed/sealed by Mark Johnson FL-PE#51983, reviewed/approved for structural compliance by the Village of Miami Shores Bldg. Dept. on 08/22, (permit set review by the Miami-Dade County Department of Regulatory and Economic Resources on 05/16/2022). Record of Field Observations: 1. Visual verification of the reinforcing steel placement at the following locations indicated below: a) Exterior column spread footing mark “F40” (4'−0"x4'−0"x1'−0") with vertical dowels at gridline E.5x12, top of footing elevation approx. −1'−4", as per S1.0, S1.1/Foundation & Concrete Column Schedules, S2.0, S2.2 and 4/S4.0, completed. b) Continuous wall footing mark “WF26” (Cont. 2’−6”x1’−0”) with vertical dowels along grid “D.6” between lines “12” thru “13” and along line “13” between grids “D.6” thru “E.5”, top of footing elevation approx. −1'−4", as per S1.0, S1.1/Foundation & Concrete Column Schedules, S2.0, S2.2, 1/S3.4 and S4.0/details 1, 3, 4 & B, completed. c) Twenty (20) exterior column spread footings mark “F26” (2'−6"x2'−6"x1'−0") for three (3) metal stairs A (118), B (117) & C (129) support (see locations on the attached sheet S2.0), top of footing elevation approx. −1'−4", as per S1.0, S1.1/Foundation Schedule, S2.0, S2.2 2/S3.0 and SUNCOR stair shop drawing sheets E4000, E4003 & E4006, completed. The reinforcing steel placement at the locations mentioned above was found to be in substantial compliance with the reference documents. In place density tests were performed by a UES technician and it was found to meet or exceed the minimum compaction requirement of 95% and ASTM D−1557. Mr. Jim Jenco, Project Superintendent with Lebolo Construction, was notified of the aforementioned visual verification results. Please see adjacent report pages for photographs, in place density draft test report and sheet S2.0. DRAFT Project No.: 2110.2100049 Report No.: 353400 Date: May 17, 2023 8050 NW 77th Court · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 STRUCTURAL OBSERVATION REPORT No. SPECIAL-024 CN: GDZ Page 2 of 4 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H-18.11, Chapter 471, Florida Statute DRAFT Project No.: 2110.2100049 Report No.: 353400 Date: May 17, 2023 8050 NW 77th Court · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 STRUCTURAL OBSERVATION REPORT No. SPECIAL-024 CN: GDZ Page 3 of 4 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H-18.11, Chapter 471, Florida Statute DRAFT UES Project No: Workorder No: Report Date: 2110.2100049.0000 352889-1 05/11/2023 8050 NW 77th Court, Miami, FL 33166 - P: 305.249.8434 - F: 305.249.8479 In-Place Density Test Report Client:Lebolo Construction Management, Inc.UES Technician:Esnel Real 2100 Corporate Drive Boynton Beach, FL 33426 Date Tested:05/08/2023 Project:Tropical Chevrolet Renovation and Expansion 8880 Biscayne Blvd , Miami Shores, County, FL 33138 Type of Test: Area Tested:Quick Lube/130 (WF26), Elevator Lobby and Pit/124 thru 126 (WF26),Tech Training/121 (WF20),Staircase Field:ASTM D-6938 Nuclear Gauge Method Material:Backfill Laboratory:AASHTO T180 Modified Proctor Reference Datum:0 = Top of Native The highlighted tests below do not meet the 95% minimum compaction requirement. Note: Retest pending client's authorization Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Staircases A/118 (F26),12 inch 108.5 12.6 109.3 9.0 101 Pass 2 Elevator Lobby and Pit/124 (WF26),12 inch 108.5 12.6 110.4 7.9 102 Pass 3 Elevator Lobby and Pit/125 (WF26),12 inch 108.5 12.6 108.3 8.7 100 Pass 4 Elevator Lobby and Pit/126 (WF26),12 inch 108.5 12.6 101.3 8.2 93 Fail 5 Elevator Lobby and Pit/126 (WF26),Retest. 12 inch 108.5 12.6 106.3 7.8 98 Pass 6 Tech Training/121 (WF20),12 inch 108.5 12.6 105.2 6.6 97 Pass 7 Staircases B/117 (F26),12 inch 107.7 11.7 105.7 5.9 98 Pass 8 Staircases C/129 (F26).12 inch 107.7 11.7 104.7 7.7 97 Pass 9 CC1 F40 GL D.7 / 11.5.12 inch 107.7 11.7 105.4 5.1 98 Pass 10 Quick Lube/130 (WF26),12 inch 107.7 11.7 106.0 4.6 98 Pass Reviewed By Universal Engineering Sciences FBPE Registry No.00000549 Carlos Naumann, P.E., S.I. Professional Engineer STATE OF FLORIDA Professional Engineer No. 18594 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1DRAFT Project No.: 2110.2100049 Report No.: 353400 Date: May 17, 2023 8050 NW 77th Court · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 STRUCTURAL OBSERVATION REPORT No. SPECIAL-024 CN: GDZ Page 4 of 4 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H-18.11, Chapter 471, Florida Statute CIP concrete footings completed on 05/17/23 Reviewed by: Universal Engineering Sciences Certificate of Authorization No. 00549 Carlos Naumann, P.E., S.I. Florida Professional Engineer No. 18594 Florida Special Inspector No. 181 DRAFT