Loading...
SPECIAL insp rept #011 (slab on grade @ service building) - GDZ + ASProject No.: 2110.2100049 Report No.: 346032 / 346245 Date: February 2, 2023 STRUCTURAL OBSERVATION REPORT No. SPECIAL-011 CN: GDZ: ASD Page 1 of 7 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H -18.11, Chapter 471, Florida Statute 8050 NW 77th Street · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 Client: Lebolo Construction Management, Inc. 2100 Corporate Drive Boynton Beach, FL 33426 Project: Tropical Chevrolet Renovation/Expansion 8880 Biscayne Blvd. Miami Shores, FL 33138 Agent: Gaetano Di Zio, E.I. Adrian Suarez Diaz Date of Services: 02/02/2023 Village of Miami Shores Building Permit No: CC-12-20-2951 (issued date 11/07/22, expires 05/08/23) Scope of Field Services: Professional observation of completed structural elements (Special/Welding Inspector). Reference Documents: • JSG structural drawings sheets S1.0 thru S-4.2 (15 pages), Bulleting 7 dated 07/21/2022, signed/sealed by Mark Johnson FL-PE#51983, reviewed/approved for structural compliance by the Village of Miami Shores Bldg. Dept. on 08/22, (permit set review by the Miami-Dade County Department of Regulatory and Economic Resources on 05/16/2022). Record of Field Observations: Visual verification for the reinforcing steel placement at the following locations indicated below: 1. Continuous wall footings as per S2.0, S1.1 & S4.0/S4.2: a) Cont. wall footing (with vertical dowels for CMU wall as per note 8) type WF26 along grids A between lines 8 thru 11 completed. b) Cont. wall footing (with vertical dowels for CMU wall & openings as per note 8 & 9/S4.0 and concrete tie columns type CC2 [x3]) type WF26 with integrated column pads type F40 (x2) along line 11 between grids A thru E.3 completed. c) Cont. wall footing (with vertical dowels for CMU wall as per note 8) type WF26 along grids E.2 between lines 8 thru 11 completed. d) Cont. wall footing (with vertical dowels for CMU wall as per note 9) type WF20 along grids D.1 between lines 11 thru proposed line 12 completed. e) Cont. wall footing (with vertical dowels for CMU wall as per note 9) type WF20 along proposed line 12 between grids D.1 thru D.6 completed. f) Cont. wall footing (with vertical dowels for CMU wall as per note 8) type WF26 along grids D.6 between lines 11 thru proposed line 12 completed. 2. Column pad footings as per S2.0, S1.1 & S4.0/S4.2: a) Column footings type F66 at grid-lines B.8x9 & D.5x9 completed (*). b) Column footings type F90 at grid-lines B.8x10 & D.5x10 completed (*). The above mentioned reinforcing steel placement was found to be performed in substantial compliance with the reference documents except (see below ↓↓↓ *) (*) as per S1.1 “column / base plate schedule: the bottom hex nut shall be “tack welded secured”. SUNCOR did not include a clarification/approval question for omission of the tack weld under dwg. Sheet AB1 “approver note”. As per approver note #2 a plate washer was approved above the previously mentioned hex nut. This plate was found to be loose (floating) not secured preventing displacement at the time of conc. placement. GC to provide clarification for the observed AS BUILT conditions. For items 2g & 2h. DRAFT Project No.: 2110.2100049 Report No.: 346032 / 346245 Date: February 2, 2023 STRUCTURAL OBSERVATION REPORT No. SPECIAL-011 CN: GDZ: ASD Page 2 of 7 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H -18.11, Chapter 471, Florida Statute 8050 NW 77th Street · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 3. Visual verification of the reinforcing steel placement at the following locations indicated below: a) 8”/12” thick CMU stem wall along grids “A” and “E.2” between lines “8” thru ”11”, along line “11” between grids “A” thru “E.2”, along grids “D.1” and “D.6” between lines “11” thru “12” and along line “12” between grids “D.1” thru “D.6”, from elevation approx. −2'−0" to 0’−0”, as per S1.0, S2.0, S2.2, 2/S3.1, 1/S3.2, S4.0/details 1, 3 & 5, 7/S4.1 and attached clarification submitted by the SEoR via e-mail, as we addressed on UES Structural Observation Reports No. 004 (No.: 341925) dated 12/02/2022 and No. 006 (No.: 342202) dated 12/05/2022, 2nd re-inspection completed: ➢ Some reinforcing steel was found to be deformed. ➢ Five (5) courses (approx. elev. +3'−4") were found to be laid on top of the stem wall. ➢ Missing/over spaced vertical reinforcing steel at some locations. ➢ Debris (chunks of masonry) was found in the CMU cells. ➢ Missing masonry interlocking of CMU wall at gridlines E.2x11 and D.6x12. ➢ Missing CMU control joint (partial) at gridline D.3x11. ➢ Missing neoprene pre-formed gasket at CMU control joints, as per 1/S1.0. To be provided for the 1st lift. ➢ Vertical dowels were found not to meet the minimum lap splice length of 48 Ø bar, as per S1.0/Masonry Note M11. ➢ CMU reinforced filled cells head joints were found not to be aligned and obstructed approx. gridline E.2x8.1, as per S1.0/Masonry Note M6. ➢ CMU horizontal reinforcement (ladder) was found not to extended into concrete tie column, as per S1.0/Masonry Note M7. b) CIP concrete tie column mark CC2 (12"x24") at gridlines B.8x11 and D.5x11, 1st lift from elevation −2'−0" (top of footing) to 0'−0", as per S1.0, S1.1/Concrete Tie Column Schedule, S2.0 and 4/S4.0, as we addressed on UES Structural Observation Report No. 006 (No.: 342202) dated 12/05/2022, re-inspection completed: ➢ Reinforcing steel was found not to meet the minimum concrete cover of 1½”, as per 4/S4.0. ➢ CMU horizontal reinforcement (ladder) was found not to extended into concrete tie column, as per S1.0/Masonry Note M7. DRAFT Project No.: 2110.2100049 Report No.: 346032 / 346245 Date: February 2, 2023 STRUCTURAL OBSERVATION REPORT No. SPECIAL-011 CN: GDZ: ASD Page 3 of 7 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H -18.11, Chapter 471, Florida Statute 8050 NW 77th Street · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 c) CIP concrete tie column mark CC2 (12"x24") at gridline E.5x11, 1st lift from elevation −2'−0" (top of footing) to 0'−0", as per S1.0, S1.1/Concrete Tie Column Schedule, S2.0, 4/S4.0 and attached clarification submitted by the SEoR via e-mail, completed. d) 8” thick interior slab on grade over a 10 Mil vapor barrier and compacted fill between grids “C.5” thru “C.8” and lines “2.8” thru “3.1” at the alignment pit, top of slab elevation approx. −0’−9”, as per S1.0, 2/S2. 1 and A100A, completed. e) New CIP concrete column footings extension (6’-0x6’-0”x1’-0”) at two (2) existing interior column footings, as per sheet S1.0R, completed. f) New CIP concrete column footings extension at existing column footings located at gridlines B.8x9, B.8x10, D.3x9 and D.3x10, as per attached drawing No. SK-01-17-23 (RFI #62), completed. g) Proposed new 6” thick interior slab on grade reinforced with 6x6 – W2.9xW2.9 W.W.F. with monolith continuous wall footing over a 10 Mil vapor barrier and compacted fill between grids “E” thru “J” and lines “3” thru “8” at the Service Building, top of slab elevation 0’−0”, as per S1.0, S2.3, 3/S4.2 and attached e-mail thread (clarification), preliminary. In place density tests were performed by a UES technician on 02/01/2023 (UES Report No. 346031−1) and it was found to meet or exceed the minimum compaction requirement of 95% and ASTM D-1557. Termite treatment was performed and vapor barrier was in placed prior to this site visit: ➢ Pending clarification/detail for continuous wall footing mark “TS16”. The reinforcing steel placement at the locations mentioned above was found to be in substantial compliance with the reference documents, except for item 1g preliminary. General Contractor will call for item 1g re-inspection after completion for final compliance verification and prior to the placement of concrete. 4. Visual verification of drilled holes for post-installed rebar dowels by means of approved anchoring epoxy Hilti HIT-HY 200 at the following locations indicated below: a) Cleanness/depth check (9” min. embedment) and epoxy application for #5 horizontal rebar dowels into existing two (2) CIP concrete footings, as per sheet S1.0 R, as we addressed on UES Structural Observation Report No. 08 (No.: 345306) dated 01/23/2023, re-inspection completed: ➢ Drilled holes were found not to meet the minimum embedment. b) Cleanness/depth check (6” min. embedment) and epoxy application for #5 horizontal rebar dowels into existing CIP concrete slab on grade along grid “E” between lines “5” thru “8”, as per 3/S4.2, as we addressed on UES Structural Observation Report No. 08 (No.: 345306) dated 01/23/2023 and 09 (No.: 345425) dated 01/25/2023, re-inspection completed: ➢ Drilled holes were found to be the same diameter as the rebars to be epoxied. ➢ Pending application of anchoring epoxy Hilti HIT-HY 200. c) Cleanness/depth check (9” min. embedment) and epoxy application for #5 horizontal rebar dowels into existing CIP concrete footings at gridlines B.8x9 and B.8x10, as per attached drawing No. SK-01-17-23 (RFI #62), completed. d) Cleanness/depth check (9” min. embedment) and epoxy application for #5 horizontal rebar dowels into existing CIP concrete footings at gridlines D.3x9 and D.3x10, as per attached drawing No. SK-01-17-23 (RFI #62), as we addressed on UES Structural Observation Report No. 09 (No.: 345425) dated 01/25/2023, re-inspection completed: ➢ Pending application of anchoring epoxy Hilti HIT-HY 200. Mr. Jim Jenco, Project Superintendent with Lebolo Construction, was notified of the aforementioned visual verification results. Please see adjacent report pages for photographs, e-mail thread, in place density draft test report, soil treatment certificate and sheet S2.3 DRAFT Project No.: 2110.2100049 Report No.: 346032 / 346245 Date: February 2, 2023 STRUCTURAL OBSERVATION REPORT No. SPECIAL-011 CN: GDZ: ASD Page 4 of 7 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H -18.11, Chapter 471, Florida Statute 8050 NW 77th Street · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 DRAFT Project No.: 2110.2100049 Report No.: 346032 / 346245 Date: February 2, 2023 STRUCTURAL OBSERVATION REPORT No. SPECIAL-011 CN: GDZ: ASD Page 5 of 7 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H -18.11, Chapter 471, Florida Statute 8050 NW 77th Street · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 DRAFT Project No.: 2110.2100049 Report No.: 346032 / 346245 Date: February 2, 2023 STRUCTURAL OBSERVATION REPORT No. SPECIAL-011 CN: GDZ: ASD Page 6 of 7 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H -18.11, Chapter 471, Florida Statute 8050 NW 77th Street · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 DRAFT 1 Gaetano Di Zio From:Jim Jenco <jjenco@Lebolo.com> Sent:Thursday, February 2, 2023 3:01 PM To:Gaetano Di Zio Cc:Adrian Diaz; Val Benitez Subject:FW: Tropical Chevrolet TS16   This Message Is From an External Sender This message came from outside your organization.   Gaetano,     Please scroll down for Johnson Structural Group TS16 spec.  I gave a printout to the guys in the field but don’t know what happened to it.  When I tried to print just now kept jamming the printer.   Kindly let me know if you need additional info.  Thanks,         Jim Jenco  Lebolo Construction Management, Inc.  jjenco@lebolo.com   I    www.lebolo.com  M: (561) 667‐9726     I    O: (561) 742‐7644    SAFETY – INTEGRITY – ACCOUNTABILITY                 From: Mark Johnson <mark@johnsonstructural.com>   Sent: Monday, June 27, 2022 11:03 AM  To: Maria Manjon <memanjon@Lebolo.com>; Brian Smedley <bsmedley@jhn.com>; Jim Jenco <jjenco@Lebolo.com>;  Pedro R. Salom <psalom@johnsonstructural.com>  Subject: RE: Tropical Chevy     Footing question was about the TS16 that we show on S2.3.       Mark Johnson, PE  USAR FL‐TF2 Structures Specialist  Johnson Structural Group, Inc.  (561) 982‐8999 x11       DRAFT 2 From: Maria Manjon <memanjon@Lebolo.com>   Sent: Monday, June 27, 2022 11:01 AM  To: Brian Smedley <bsmedley@jhn.com>; Jim Jenco <jjenco@Lebolo.com>; Pedro R. Salom  <psalom@johnsonstructural.com>  Cc: Mark Johnson <mark@johnsonstructural.com>  Subject: RE: Tropical Chevy     Brian,     Understood!      Sorry for any inconvenience     Thank you,        Maria E Manjon      Project Executive      Lebolo Construction Management, Inc.     memanjon@lebolo.com | www.lebolo.com     m. (561) 859-6598 | o. (561) 742-7644                   SAFETY – INTEGRITY – ACCOUNTABILITY     This e‐mail is subject to the Electronics Communications Privacy Act, 18 U.S.C. § 2510‐2521, and may be legally privileged. The information contained in this e‐mail message is  confidential information intended only for the use of the individual or entity named above. If the reader of this message is not the intended recipient, you are hereby notified  that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please immediately notify sender  by telephone at 561‐742‐7644, and delete the original message. Thank you.                 From: Brian Smedley <bsmedley@jhn.com>   Sent: Monday, June 27, 2022 10:49 AM  To: Jim Jenco <jjenco@Lebolo.com>; Pedro R. Salom <psalom@johnsonstructural.com>  Cc: Mark Johnson <mark@johnsonstructural.com>; Maria Manjon <memanjon@Lebolo.com>  Subject: RE: Tropical Chevy     Team:  It appears that there has been correspondence that I have not been copied on.  Please make sure to copy me on all  project correspondence.  I am completely in the dark as to what has lead us to this point.     DRAFT 3 BRIAN SMEDLEY, AIA NCARB |Director ‐ Automotive Group  bsmedley@jhn.com  Office: 248.324.8800 x104 | Cell: 586.764.1743     NUDELL ARCHITECTS  Michigan | 30403 West 13 Mile Road | Farmington Hills, MI 48334    Florida  |  1807 Edgewater Drive (College Park) | Orlando, Florida 32804     From: Jim Jenco <jjenco@Lebolo.com>   Sent: Monday, June 27, 2022 10:46 AM  To: Brian Smedley <bsmedley@jhn.com>; Pedro R. Salom <psalom@johnsonstructural.com>  Cc: Mark Johnson <mark@johnsonstructural.com>; Maria Manjon <memanjon@Lebolo.com>  Subject: RE: Tropical Chevy     Brian,     Pedro visited the site twice to address the existing Mezzanine structure. While he was on site I asked him a question  relating to the ftg size of the non‐bearing masonry walls which he answered this morning but did not answer the  Mezzanine issue.      From: Brian Smedley <bsmedley@jhn.com>   Sent: Monday, June 27, 2022 10:40 AM  To: Jim Jenco <jjenco@Lebolo.com>; Pedro R. Salom <psalom@johnsonstructural.com>  Cc: Mark Johnson <mark@johnsonstructural.com>; Maria Manjon <memanjon@Lebolo.com>  Subject: RE: Tropical Chevy     Jim:  To make sure we’re all on the same page with the mezzanine question, below is a snip from the original email you sent  to me regarding the mezzanine demolition.  Are there any additional questions related to the Mezzanine demo, other  than the below?    DRAFT 4      BRIAN SMEDLEY, AIA NCARB |Director ‐ Automotive Group  bsmedley@jhn.com  Office: 248.324.8800 x104 | Cell: 586.764.1743     NUDELL ARCHITECTS  Michigan | 30403 West 13 Mile Road | Farmington Hills, MI 48334    Florida  |  1807 Edgewater Drive (College Park) | Orlando, Florida 32804     From: Jim Jenco <jjenco@Lebolo.com>   Sent: Monday, June 27, 2022 8:49 AM  To: Pedro R. Salom <psalom@johnsonstructural.com>  Cc: Mark Johnson <mark@johnsonstructural.com>; Brian Smedley <bsmedley@jhn.com>; Maria Manjon  <memanjon@Lebolo.com>  Subject: RE: Tropical Chevy     Pedro,     What happened to the primary RFI pertaining to the Mezzanine demolition?   I don’t see anything relating to what to do with the existing columns that are supporting the Conventional Concrete Roof  System.  Thew Demolition Crew has left the site until they have answers.  Please consult with Brian Smedley ASAP and respond accordingly.     Thanks,      Jim Jenco  Project Manager/Project Superintendent  Lebolo Construction Management, Inc.  jjenco@lebolo.com   I    www.lebolo.com DRAFT 5 M: (561) 667‐9726     I    O: (561) 742‐7644    SAFETY – INTEGRITY – ACCOUNTABILITY                 From: Pedro R. Salom <psalom@johnsonstructural.com>   Sent: Monday, June 27, 2022 7:31 AM  To: Jim Jenco <jjenco@Lebolo.com>  Cc: Mark Johnson <mark@johnsonstructural.com>  Subject: FW: Tropical Chevy     Good morning Jim, see answer below from MJ regarding your questions, I asked him about the missing reinf.     My apologies that I was not able to deliver on Saturday.       My oldest son had some health issues that we needed to attend to.       Thank Good he is almost back to normal.  I’ll keep you posted on the columns.     Thanks.             Pedro Salom, P.E.  JohnsonStructuralGroup,Inc.  160 West Camino Real  Suite 1000  Boca Raton, FL  33432  Phone (561) 982‐8999 Ext. 13  Fax: (561) 982‐8899  www.johnsonstructural.com        From: Mark Johnson <mark@johnsonstructural.com>   Sent: Friday, June 24, 2022 12:22 PM  To: Pedro R. Salom <psalom@johnsonstructural.com>  Subject: RE: Tropical Chevy     Afternoon sir.  The TS16 is Cont. x 12” High x 18” wide.  We had both details because at certain areas where they were  taking out the floor slab and re‐pouring, the top detail would apply.  See the snip below with the white section I  added.  Where the 3/S4.2 is cut in the snip, I would anticipate the bottom detail to apply.     I concur about the filling in of the pit.  He should just send an RFI asking how to deal with it.    DRAFT 6     Mark Johnson, PE  USAR FL‐TF2 Structures Specialist  Johnson Structural Group, Inc.  (561) 982‐8999 x11        From: Pedro R. Salom <psalom@johnsonstructural.com>   Sent: Thursday, June 23, 2022 3:36 PM  To: Mark Johnson <mark@johnsonstructural.com>  Subject: RE: Tropical Chevy     Will do. Thanks.       BTW see snip below.. Jim was asking for the reinf. for the TS16 ‐not shown on sch. Also see detail 3/S4.2‐see snip‐ I  assume is the one on the bottom? Despite it says TS16 on plan?.. The one on top seems to be for another TS?.. and also  he wants to widen the areas where they removed the CMU to place the new s.o.g. I told him it was OK the reason it is  because is easier to dowel in.     The attached pictures show an existing trench that I told him he will need to fill with dirt, compacted and then use detail  7/S4.2. He still wants a detail for it.     DRAFT 7      DRAFT 8        Pedro Salom, P.E.  JohnsonStructuralGroup,Inc.  160 West Camino Real  Suite 1000  Boca Raton, FL  33432  Phone (561) 982‐8999 Ext. 13  Fax: (561) 982‐8899  www.johnsonstructural.com        From: Mark Johnson <mark@johnsonstructural.com>   Sent: Thursday, June 23, 2022 10:25 AM DRAFT 9 To: Pedro R. Salom <psalom@johnsonstructural.com>  Subject: Tropical Chevy     Morning. Add an hour of my time for yesterday for review to your time sheet.  Thank you sir.         Mark Johnson, PE  USAR FL‐TF2 Structures Specialist  Johnson Structural Group, Inc.  New Mailing Address:  160 West Camino Real  Suite 1000  Boca Raton, FL  33432  Phone (561) 982‐8999 Ext. 11  www.johnsonstructural.com       DRAFT UES Project No: Workorder No: Report Date: 2110.2100049.0000 345829-1 02/01/2023 8050 NW 77th Court, Miami, FL 33166 - P: 305.249.8434 - F: 305.249.8479 In-Place Density Test Report Client:Lebolo Construction Management, Inc.UES Technician:Alfredo Espinoza 2100 Corporate Drive Boynton Beach, FL 33426 Date Tested:01/30/2023 Project:Tropical Chevrolet Renovation and Expansion 8880 Biscayne Blvd , Miami Shores, County, FL 33138 Type of Test: Area Tested:Alignment pit S2.1 Field:ASTM D-6938 Nuclear Gauge Method Material:Fill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill Depth requirement is 12.00 inches The tests below meet the 98% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Fill Depth (inch) Pass or Fail 1 Alignment pit S2.1 12 inch 108.5 12.6 100.9 6.9 93 12.00 Fail 2 Alignment pit S2.1 (RETEST)12 inch 108.5 12.6 105.9 10.6 98 12.00 Pass Reviewed By Universal Engineering Sciences FBPE Registry No.00000549 Carlos Naumann, P.E., S.I. Professional Engineer STATE OF FLORIDA Professional Engineer No. 18594 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1DRAFT UES Project No: Workorder No: Report Date: 2110.2100049.0000 346031-1 02/02/2023 8050 NW 77th Court, Miami, FL 33166 - P: 305.249.8434 - F: 305.249.8479 In-Place Density Test Report Client:Lebolo Construction Management, Inc.UES Technician:Esnel Real 2100 Corporate Drive Boynton Beach, FL 33426 Date Tested:02/01/2023 Project:Tropical Chevrolet Renovation and Expansion 8880 Biscayne Blvd , Miami Shores, County, FL 33138 Type of Test: Area Tested:Service Building Field:ASTM D-6938 Nuclear Gauge Method Material:Fill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Service Building GL C / 10.3 12 inch 108.5 12.6 106.0 5.0 98 Pass 2 Service Building GL C / 8 12 inch 108.5 12.6 103.8 5.0 96 Pass 3 Service Building GL D / 9.2 12 inch 108.5 12.6 104.0 3.8 96 Pass 4 Service Building GL D / 10.3 12 inch 108.5 12.6 105.1 4.7 97 Pass 5 Service Building GL C.5 / 4 12 inch 108.5 12.6 108.0 2.9 100 Pass 6 Service Building GL C.5 / 6 12 inch 108.5 12.6 107.6 4.9 99 Pass 7 Service Building GL C.5 / 7 12 inch 108.5 12.6 105.4 3.0 97 Pass Reviewed By Universal Engineering Sciences FBPE Registry No.00000549 Carlos Naumann, P.E., S.I. Professional Engineer STATE OF FLORIDA Professional Engineer No. 18594 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1DRAFT DRAFT Project No.: 2110.2100049 Report No.: 346032 / 346245 Date: February 2, 2023 STRUCTURAL OBSERVATION REPORT No. SPECIAL-011 CN: GDZ: ASD Page 7 of 7 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H -18.11, Chapter 471, Florida Statute 8050 NW 77th Street · Miami, FL 33166 · P: 305.249.8434 · F: 305.249.8479 Slab on grade preliminary Reviewed by: Universal Engineering Sciences Certificate of Authorization No. 549 Carlos Naumann, P.E., S.I. Florida Professional Engineer No. 18594 Florida Special Inspector No. 181 DRAFT