Loading...
Tropical Chevrolet, 11-18-22 UES No 341357 SPECIAL insp rept #002 - HCProject No.: 2110.2100049 Report No.: 341357 Date: November 18, 2022 STRUCTURAL OBSERVATION REPORT No. SPECIAL-002 CN: HC Page 1 of 5 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H-18.11, Chapter 471, Florida Statute 8050 NW 77th Street ꞏ Miami, FL 33166 ꞏ P: 305.249.8434 ꞏ F: 305.249.8479 Client: Lebolo Construction Management, Inc. 2100 Corporate Drive Boynton Beach, FL 33426 Project: Tropical Chevrolet Renovation/Expansion 8880 Biscayne Blvd. Miami Shores, FL 33138 Agent: Humberto Carvajal CWI14060641 Date of Services:11/18/2022 Village of Miami Shores Building Permit No: CC-12-20-2951 (issued date 11/07/22, expires 05/08/23). Scope of Field Services: Professional observation of completed structural elements (Special/Welding Inspector). Reference Documents:  JSG structural drawings sheets S1.0 thru S-4.2 (15 pages), Bulleting 7 dated 07/21/2022, signed/sealed by Mark Johnson FL-PE#51983, reviewed/approved for structural compliance by the Village of Miami Shores Bldg. Dept. on 08/22, (permit set review by the Miami-Dade County Department of Regulatory and Economic Resources on 05/16/2022). Record of Field Observations: Visual verification for the reinforcing steel placement at the following locations indicated below: 1. Continuous wall footings as per S2.0, S1.1 & S4.0/S4.2: a) Cont. wall footing (with verical dowels for CMU wall as per note 8) type WF26 along grids A between lines 8 thru 11 completed (**). b) Cont. wall footing (with verical dowels for CMU wall & openings as per note 8 & 9/S4.0 and concrete tie columns type CC2 [x3]) type WF26 with integrated column pads type F40 (x2) along line 11 between grids A thru E.3 completed. c) Cont. wall footing (with verical dowels for CMU wall as per note 8) type WF26 along grids E.2 between lines 8 thru 11 completed (**). d) Cont. wall footing (with verical dowels for CMU wall as per note 9) type WF20 along grids D.1 between lines 11 thru proposed line 12 completed. e) Cont. wall footing (with verical dowels for CMU wall as per note 9) type WF20 along proposed line 12 between grids D.1 thru D.6 completed. f) Cont. wall footing (with verical dowels for CMU wall as per note 8) type WF26 along grids D.6 between lines 11 thru proposed line 12 completed. 2. Column pad footings as per S2.0, S1.1 & S4.0/S4.2: g) Column footings type F66 at grid-lines B.8x9 & D.5x9 completed (*). h) Column footings type F90 at grid-lines B.8x10 & D.5x10 completed (*). The above mentioned reinforcing steel placement was found to be performed in substantial compliance with the reference documents except (see below ↓↓↓ *, **, ***) (*) as per S1.1 “column / base plate schedule: the bottom hex nut shall be “tack welded secured”. SUNCOR did not include a clarification/approval question for omission of the tack weld under dwg. Sheet AB1 “approver note”. As per approver note #2 a plate washer was approved above the previously mentioned hex nut. This plate was found to be loose (floating) not secured preventing displacement at the time of conc. placement. GC to provide clarification for the observed AS BUILT conditions. For items 2g & 2h. (**) required [if applicable] drilled & epoxy dowels missing as per 1/S4.2 for items 1a & 1c. (**) installation of the additional reinforcing for the proposed “MCJ” was found to be missing at the time of this site visit as per 1/S1.0 for items 1a thru 1h. Project No.: 2110.2100049 Report No.: 341357 Date: November 18, 2022 STRUCTURAL OBSERVATION REPORT No. SPECIAL-002 CN: HC Page 2 of 5 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H-18.11, Chapter 471, Florida Statute 8050 NW 77th Street ꞏ Miami, FL 33166 ꞏ P: 305.249.8434 ꞏ F: 305.249.8479 In place density tests were performed for the above mentioned locations and were found to meet or exceed the minimum requirement of 98% compaction as per ASTM D1557. Project No.: 2110.2100049 Report No.: 341357 Date: November 18, 2022 STRUCTURAL OBSERVATION REPORT No. SPECIAL-002 CN: HC Page 3 of 5 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H-18.11, Chapter 471, Florida Statute 8050 NW 77th Street ꞏ Miami, FL 33166 ꞏ P: 305.249.8434 ꞏ F: 305.249.8479 Project No.: 2110.2100049 Report No.: 341357 Date: November 18, 2022 STRUCTURAL OBSERVATION REPORT No. SPECIAL-002 CN: HC Page 4 of 5 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H-18.11, Chapter 471, Florida Statute 8050 NW 77th Street ꞏ Miami, FL 33166 ꞏ P: 305.249.8434 ꞏ F: 305.249.8479 Mr. Jim Jenco, Project Superintendents with Lebolo Construction, was notified of the aforementioned visual verification results. Project No.: 2110.2100049 Report No.: 341357 Date: November 18, 2022 STRUCTURAL OBSERVATION REPORT No. SPECIAL-002 CN: HC Page 5 of 5 cc: 1 − Job Site; 1 − Client; 1 The Original of this Report was Signed and Impressed Sealed by the Above Registered Engineer in Accordance with Rule 21H-18.11, Chapter 471, Florida Statute 8050 NW 77th Street ꞏ Miami, FL 33166 ꞏ P: 305.249.8434 ꞏ F: 305.249.8479 Reviewed by: Universal Engineering Sciences Certificate of Authorization No. 549 Carlos Naumann, P.E., S.I. Florida Professional Engineer No. 18594 Florida Special Inspector No. 181