Loading...
RC-01-23-111 SurveyBOUNDARY SURVEY SCALE: 1" = 20' TREE LEGEND T= Trunk 0 at breast height, H= Height, C= Canopy 1. West Indian Mahogany T= 1. 5' H= 40' C= 30' 2. West Indian Mahogany T= 1.5' H= 40' C= 30' 3. Starburst Bush T= 0.5' H= 18' C= 10' 4. Oriental Arborvitae T= 0.2' H= 5' C= 2' 5. Oriental Arborvitae T= 0.2' H= 5' C= 2' 6. Oriental Arborvitae T= 0.2. H= 12' C= 3' 7. Oriental Arborvitae T= 0.2. H= 12' C= 3' 8. Oriental Arborvitae T= 0.5' H= 18' C= 3' 9. Oriental Arborvitae T= 0.5' H= 18' C= 3' 10. Spineless Yucca T= 0.5' H= 15' C= 8' 11. Coconut Palm T= 0.6' H= 10' C= 10' 12. Bottle Palms (4) T= 0.5' H= 15' C= 8' 13. Bottle Palms (4) T= 0.3' H= 8' C= 5' 14. Bottle Palms (3) T= 0.5' H= 8' C= 5' 15. Bottle Palms (4) T= 0.5' H= 8' C= 5' 16. Weeping Fig T= 5.0' H= 40' C= 40' 17. Bottle Palms (9) T= 0.4' H= 15' C= 5' 18. Mango tree T= 2.0' H= 40' C= 35' 19. Traveller's Palm T= 0.3' H= 15' C= 10' 20. Bougainvillea T= 0.3' H= 8' C= 7' 21. Magenta Cherry T= 0.5' H= 20' C= 10' Tree location and dimension are approximate. For proper and scientific tree name an arborist should be contacted. NE :dM SI NEB}:,f :A NC.')?tC St t:i 9'M 51 Ni i]Mu NE *Ad PROPERTY ADDRESS: 390 NE 93rd St. Miami Shores, FL. 33138 LOCATION MAP JN NOT TO SCALE LEGAL DESCRIPTION: Lot 1 and the East %2 of Lot 2, Block 47, of AMENDED PLAT OF MIAMI SHORES SECTION ONE, according to the plat thereof as recorded in Plat Book 10, at Page 70, of the Public Records of Miami Dade County, Florida. NOTES: Before any construction the setbacks must be checked The certificate does not extended to any unnamed party Elevations are referred to Miami Dade County BM# N-603-R Elev.= 8.06' of N.G.V.D. of 1929 There may be Easements recorded in Public Records not shown on this Survey. LEGEND AND ABBREVIATIONS A= ARC DISTANCE P.B.= PLAT BOOK p = ELEVATION ® = CATCH BASIN AC= AIR CONDITIONED UNIT P.C.P = PERMANENT CONTROL POINT k0 ADJ= ADJACENT P.G.= PAGE ® = SANITARY SEWER B.C= BLOCK CORNER P.O.B.= POINT OF BEGINNING ®W = WATER METER wv BLDG.= BUILDING P.O.C.= POINT OF COMMENCE = WATER VALVE B.O.B.= BASIS OF BEARINGS P.P.= POOL PUMP �Q� = POWER POLE CCLEAR R= RADIUS TV BOX ' C.L.L.F=CHAIN LINK FENCE RES.= RESIDENCE = LIGHT POLE CONC.= CONCRETE R/W= RIGHT-OF-WAY = FPL TRANS. D.M.E.= DRAINAGE MAINT. EASEMENT TYP= TYPICAL ®= FIRE HYDRANT FD.= FOUND U.E = UTILITY EASEMENT ® = CONC. POWER POLE F.F.ELEV.: FINISHED FLOOR ELEVATION W.F.= WOOD FENCE ®=MANHOLE I.F.= IRON FENCE 0= DIAMETER JOB NUMBER: 220918 L.F.ELEV.: LOWEST FLOOR ELEVATION q= CENTER LINE BASED ON THE FLOOD INSURANCE RATE MAP OF THE FEDERAL EMERGENCY AGENCY REVISED ON 9-11-09 THE HEREIN DESCRIBED PROPERTY IS SITUATED WITHIN: ZONE X BASE FLOOD ELEV. N/A COMMUNITY NUMBER: 120652 PANEL NUMBER 0302 SUFFIX L LEGAL NOTES THIS SURVEY DOES NOT REFLECT OR DETERMINE OWNERSHIP. EXAMINATION OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFECTING THE PROPERTY. THIS SURVEY IS SUBJECT TO DEDICATION, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EASEMENTS OF RECORDS. LEGAL DESCRIPTION PROVIDED BY CLIENT. THE LIABILITY OF THIS SURVEY IS LIMITED TO THE COST OF THE SURVEY. UNDERGROUND ENCROACHMENTS, IF ANY, ARE NOT SHOWN. THIS FIRM HAS NOTATTEMPTED TO LOCATE FOOTING AND/OR FOUNDATIONS AND/OR UNDERGROUND IMPROVEMENTS OF ANY NATURE. IF SHOWN BEARINGS ARE REFERRED TO AN ASSUMED MERIDIAN. THE CLOSURE IN THE BOUNDARY SURVEY IS ABOVE 1: 10000. THIS SURVEY IS NOT INTENDED FOR NEITHER DESIGN NOR CONSTRUCTION PURPOSES. FOR THOSE PURPOSES ATOPOGRAPHIC SURVEY IS REQUIRED. CERTIFIED TO: Felipe Caro 1ILF-ILINUL12Q) FLF-121❑ PROFESSIONAL LAND SURVEYOR & MAPPER 14317 S.W. 45th Terrace Miami, Florida 33175 Tel: (305) 552-7504 Fax: (305) 229-8068 E-mail: enpav@yahoo.es DATE OF FIELD WORK: REVISED ON: I hereby certify that the attached Sketch of Survey of the herein described property is to the best of my knowledge and belief, a true and correct representation, of a field survey performed under my direction. And also meets the Minimum Technical Standards as set forth by the Florida Board of Professional Surveyors and Mappers in chapter 5J-17.050 thru 5J-1 2 A.C. pursuant to Section 472.027 F. S. ' A ARTUR❑ R. TOIRAC P.S.M. 31 02 Not valid without the signature and the original embosed seal of a Florida Licensed Surveyor and Mapper.