RF-19-1293Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Location Address
149 NE 106TH ST, Miami Shores, FL 33138
rnntartc
, ?D(f=)ffnLNU11
Issue Date: 06/11/2019
Parcel Number
1121360060370
Permit NO.: RF-06-19-1293
Permit Type., Roof
Work Classification: tile
Permit Status: Approved
Expiration: 12/09/2019
LIZ MARIE ALLEN Owner TOP SEAL SERVICES CORP Contractor
855 NE 111 ST, MIAMI, FL 33161 RONALD MEDINA
Business: 3057547844
ti
Description: RE -ROOF TILE TO TILE Valuation: $ 15,000.00 on Requests:
Inspection
4949
Total Sq Feet: 2,000.00 _j I
Fees
Amount
Application Fee - Other
$50.00
CCF
$9.00
DBPR Fee
$4.13
DCA Fee
$2.75
Education Surcharge
$3.00
Roofing Fee
$225.00
Scanning Fee
$9.00
Technology Fee
$6.88
Total:
$309.76
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$309.76
Check # 5664
06/11/2019 $309.76
Amount Due:
$0.00
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
reguiaMig-eQpstruction and zoning. Futhermore, I authorize the above named contractor to do the work stated.
Signature: Owner
/ Applicant / Contractor / Agent
Date
June 11, 2019 Page 2 of 2
BUILDING
PERMIT APPLICATION
❑BUILDING ❑ ELECTRIC
❑PLUMBING ❑ MECHANICAL
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY:
Tel: (305) 795-2204 Fax: (305) 7S6-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
6 2 9
FBC 20 Master Permit No. r b "' 1 1G 1' N 3
Sub Permit No.
03OFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PUBLIC WORKS [:]CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: ( 4a / ` S' zO
City: Miami Shores County: Miami Dade Zip: ?:o ( 35?1
Folio/Parcel#: Is the Building Historically Designated: Yes NO
Occupancy Type: Load: / ,Construction Type: Flood Zone: BFE: G FF,FFEEj:` [�
OWNER: Name (Fee Simple Titleholder): (/J `' ' (�t e- � `'U' 1 Phone#: �D�i ' ✓t J • (3 -y
Address:�� 1`� C� t I I 4S4- �Q
City: ,sc&dv� //��Pa� Y6 State: /o _(.J__ Zip: --J 14, t
Tenant/Lessee Name: ;/ I/ h u �� `G t 1 Phone#: ��J• `-t �q 2
Email:
CONTRACTOR: Company Name:
Address: <9 si A )
'o- ear CI'Ue
T.p S-Q ,9'
J , G--Q1
ne#: Tyt.-z' /C)
City: c State: 1 \ Zip: 562 7
Qualifier Name: Phone#:
State Certification or Registration #: n rjCertificate of Competency M
DESIGNER: Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ I o q) Square/Linear Foota e of Work: (�
Type of Work: ❑ Addition ❑ Alteration El New Repair/Replace ❑Demolition
Description of Work: / e� 1 ► rL �TC� ) .Q
Specify color of color Mru tile:
Submittal Fee $ Permit Fee $
Scanning Fee $ Radon Fee $
Technology Fee $ Training/Education Fee $
Structural Reviews $ _
(Revised02/24/2014)
CCF $_
DBPR $
CO/CC $
Notary $
Double Fee $ hh
Bond $ V �C)� ll
TOTAL FEE NOW DUE $ � b—I j V
809 '-1 �
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING JO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
,YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of comme nt must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In he abse ce of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature Signature
OWNER or AGENT CONT TOR
The foregoing instrument was acknowledged before me this The foregoing instrum nt was acknowledged before me this
J day of ` 20, by day of 'S 20, by
, who is personally known to ry1st CXC--: who is personally known to
me or who has produced as me or who has produced as
identification and who did take an oath.
identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
i
Sign: Sign:
Print: 86k.-L L. L-we Print: Cat
Seal: BARBARA LOPEZ
MY COMMISSION #GG250964
a EXPIRES: AUG 21, 2022
anD Brdctiri 1st Sa InsurancE
APPROVED BY
Seal:
MY COMMISSION # GG041319
EXPIRES October 24. 2020
C Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
A
F
2018
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D {Steep Sloped Roof System)
Roof System Manufacturer: Boral Roofing Tile
Notice of Acceptance Number: 18-05Q9.16
Minimum Design Wind Pressures, if Applicable (From RAS 12T or Calculations):
P1: 4.70 P2: 13.83 P3: 24.10
Maximum Design Pressure •
From the NOA Specific S stem : 45.5 , , , , , •
Method of the attachment: ICP One Medium Patty 24 gra sleach ....
Steep Sloped Roof System Description ••
Deck Typ
Plywood 5/8
nderlayment•
Roof Slope:
Xnsulation:
3 :12
Ridge Ventilation?
N/A
Mean Roof Height.-! 3
30# ASTM D 7-2-C * ype -11:
N/A
N/A
nor Type & Spacing: 1 1 /4" RS Coil & 1 5/8" TC
-"-I Self -Adhered
Cap Sheet:
Polyglass TU
7oof Covering: Villa 900
Type & Size Drip
Edge: '-'
F3x3 26 ga Galy.
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section E [Tile Calcuiatlonsl
For Moment based the systems, choose either Method 1 or 2. Compared the values
for M,with the values from MN llf the M f values are greater than or equal to the Mr
values, for each area of the roof, then the file attachment method is acceptablle.
Method 1 "Moment Based Tile Calculations Per RAS 127"
(P1:39.1 zx .3j5 a 12.31 - Mg, _-7.62-K1,.4.59 NOAK 45) S_ ICP I Medium
(P=: 68.1 x 1 .315 21 4s l _Mg: 7.62 - h4 , 3.83 NOA K 45.5 . patty 24 g ram:
(p3: 100.7 x). .315 31.72-) - Mg; 7.62 - M,.3, za;1 NOA Mf 45.5 each
Method 2 "Simplified T''lle Calculation Per Table Below"
Required Moment of Resistance (K) From Table Below NOA Mf • •
M, Required Moment Resistance` • • • • •
BM —
Roof Sfopo
15'
20'
29
306y:
4M • • •
M
3ti.5
.�• •
• • •
—Sz•
• •
• •
egAs•
&,12
28A
30.1
•
349 •
8:12\"
2l3 4
28.0
'ZTJ
•
a2
.8
; '
• • •
.0
*Must be used In conjune u with a last of moment based We systems endorsed by the • • • •
Broward County Board of and Appeals.
For Uplift based We systems us Method 3,/Gompared the values for F' with the
values for Fr. If the F' values are kkeatsrkhan or equal to the Fr values, for each
area -of the roof, then the isle attachme ethod is acceptable.
Method 3 "Upfift Based Ti Calculations Per RAS 127"
w: -,,Lj— W : — z so. _ A Fr': _ NOA F'
(pz:-xl:_-_x w;—W:___ xcos Ft2: NOAF'
(p3 : z 1: — z a6 = —.) — W : Y„-, z cds t9: , = F,s: ____ NOA P'
/ Where to Obtain iinforma ' n
Description
Symbol I
Where to find
DtsSpri Pmssme
PlorMorP3
RAS 127 Table 1 a by an emgmeea hgrnsiy=pmpatod by Masai om ASCB
7 \.
M= Roo Heit
H
Job Sito
Rwfslope
a
Job Site
lien
NOA \
Rescdft Momeat due to Gmn
M
NOA
Att•chmmt Remstmoe
Mr
NOA
MomeaReAft=
K
I Calculated
NOA
Rtsiefltace
—
Fr
wallaw
AycapTue Wei
NOA
1IIc Dimensions
1- IM4
W- width
NOA
All csIM94OW must be ZmiMad to the B OfScsalattbofteofPernaitaplicaton,
IiIIIIIIIIIIIft
M�MIDADE IA•
1�:K: MMIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economv
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miarni-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Controi gection
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the;WA to have this "
product or material tested for quality assurance purposes, if this product or material fails to perfQl ly jq the aoo0 0,10
manner, the manufacturer will incur the expense of such testing and the AHJ may immediatelyrEyo) ;, modify, of
suspend the use of such product or material within their jurisdiction. RER reserves the right to qypj a this acjVJ§nce,
if it is determined by Miami -Dade County Product Control Section that this product or material fail%?b meet'tpe.. •
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with tite Florida.$uiR ing Cfdr.'
including the High Velocity Hurricane Zone of the Florida Building Code. • • • • •.
DESCRIPTION: Boral Villa 900 Concrete Roof Tile :' •"'
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and fofittAng
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.16-0711.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Senzino 0
MIAMI.DQDE COUNTY
NOA No.: 18-0509.16
• Expiration Date: 09/21/21
Approval Date: 06/28/18
Page I of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing, LLC in Lake
Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure
requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by
calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations
shall be done as a moment based system.
2. PRODUCT DESCRIPTION
• •
Manufactured by Test Prkuci'.
Applicant Dimensions Specifications DesccrrijTiio_rn'
. .. .
Boral Roofing Villa 900 Length = 17" TAS 112 Low profile, interlockinpl gkipressure extruded
......
Width = 13" Type lb concrete roof tile equippedowith three naaholes
'h" thick Class III and double rolls. For dirmtdtck, battepipm- tar
•....
or adhesive set applicatif5flV • • • • • •
• • • • •
Trim Pieces " •
1=varies TAS 1 1. Accessory trim, concretg jQgf�ieces for use at
• • • • • •
w = varies ridges, hips and rakes. • ;
�.
•
0 0
varying thickness • • • • •
. .
0
•.••••
of
2.1 PRODUCTS MANUFACTURED BY OTHERS 00:000
Product Name Product Description Manufacturer
(With Current NOA)
ICP Adhesives Polyset® AH-160 Two component polyurethane ICP Adhesives and Sealants, Inc.
foam adhesive.
TILE BONDTM Roof Tile Adhesive Single component polyurethane The Dow Chemical Company
foam roof tile adhesive.
"Tile Tite" Roof Tile Mortar Preinixed, pre -bagged roof the Bermuda Roof Co. Inc.
mortar.
DAP Foam Touch N Seal Two component polyurethane The Dow Chemical Company
StormBond02 Roof Tile Adhesive foam adhesive.
2.2 MANUFACTURING LOCATION
2.2.1. Lake Wales, FL
MIAMIOADE COUNTY= NOA No.: 18-0509.16
�Ijuw.(IrnsExpiration Date: 09/21/21
Approval Date: 06128JIS
Page 2 of 7
2.3 EVIDENCE SUBMITTED
Test Agency
Nutting Engineers
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation
Testing Services
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
American Test Lab of South
Florida
Test Identifier
13343.1
7161-03
Appendix III
7161-03
Appendix II
P0402
94-060B
94-084
P0631-01
Letter Dated Aug. 1, 1994
Project No. 307025
Test #MDC-76
25-7183-1
25-7183-2
25-7214-2
25-72 l 4-6
528454-2-1
520109-2
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
RT0617.02-16
Test Name/Renort
TAS 112
Static Uplift Testing
TAS 102 & TAS 102(A)
Wind Tunnel Testing
TAS 108 (Nail -On)
Withdrawal Resistance Testing of
screw vs. smooth shank nails
Static Uplift Testing
TAS 101 (Adhesive Set)
Static Uplift Testing •
TAS 101 (Mortar Set) • • • •
Wind Tunnel Testing • • • • •
TAS 108 (Mortar Set) • • • • • •
Wind Tunnel Testing •
TAS 108 (Nai 1-On) ......
Wind Driven Rain • • • •
TAS 100 ;••;•;
Static Uplift Testing : • •
TAS 102 0..o •
(2 Quik-Drive Screws, Direct Deck)
Static Uplift Testing
TAS 102
(1 Quik-Drive Screw, Direct Deck)
(I Quik-Drive Screw, Battens)
Static Uplift Testing
TAS 101
25-7183
25-7094
25-7496
25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
Aerodynamic Multipliers
Two Patty Adhesive Set Systern
Restoring Moment Due to Gravity
TAS 112
Date
Apr. 2006
Dec. 1991
Dec, 1991
Sept. 1993
March, 1994
Map W4•
Aug.*1 M4
On.
Fete 4 94
March, 1995
Sep. 1998
Dec. 1998
March 1995
February 1996
April 1996
December 1996
09/01/16
April 1999
09/01/16
06/29/16
MIAMI•MADECauNTy NOA No.: 18-0509.16
Expiration Date: 09/21/21
Approval Date: 06/28/18
Page 3of7
2.3 EVIDENCE SUBMITTED
Test Aaencv Test Identifler Test Name/Report Date
PRI Construction Materials COPO-002-02-11 Static Uplift Testing 10/12/2016
Technologies TAS 101 (Adhesive Set)
PRI Construction Materials COPO-002-02-04 Static Uplift Testing 10/1212016
Technologies TAS 101 (Adhesive Set)
PRI Construction Materials COPO-002-02-03 Static Uplift Testing 10/12/2016
Technologies TAS 101 (Adhesive Set)
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS
106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perf9n quarterly•tsst in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Buildl'ng Code Catr+Cloiance
Office for review. • • • • • • •
3.4 Minimum underlayment shall be in compliance with the applicable Roofing ApplicpyQps Standgj% fisted
section 4.1 herein. •
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the*Mpf %tope ulless, stated
otherwise by the underlayment material manufacturers published literature. • • • • • • •
3.6 This acceptance is for wood deck applications. Minimum deck requirements shalt: beirrncomplianc with
applicable building code. .... a
4. INSTALLATION •
4.1 Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing
Application Standard RAS 118, RAS 119, and RAS 120,
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Welght-W (lbf)
Length-1 (ft)
Width-w (ft)
Villa 900 Concrete Tile
10.90
1.42
1.08
Table 2: Aerodynamic Multipliers - X (ft3)
Tile
Profile
1(w)
Batten Application
R (w)
Direct Deck Application
Villa 900 Concrete Tile
0.291
0.315
Table 3: Restoring Moments due to Gravity - M9 (ft.-lbf.)
Tile
2"•12"
311•12"
4":12"
5"12"
6":12"
7":12" or
Profile
greater
Villa 900
Direct
Direct
Battens
Direct
Battens
Direct
I
Battens i Direct
Battens
Direct
Concrete Tile
Deck
Deck
Deck
Deck
Deck
Deck
7.70
7.62
6.56
7.50
6.42
1 7.34
6.26 7.15
6.08
6.95
MIAMWAD COUNTY NUA No.: 18-0�09.16
O Expiration Date: 09/21/21
Approval Date: 06/28/18
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Mechanically Fastened Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(min 16/32" plywood)
(min. 19132" plywood)
Villa 900
Concrete Tile
2-10d Ring Shank Nails
27.8
37.4
28.8
1-10d Smooth or Screw
8.8
11.8
4.1
Shank Nail
2-10d Smooth or Screw
16.4
21.9
7.1
Shank Nails
1 #8 Screw
25.8
25.8
22.9
2 #8 Screw
47.1
47.1
49.1
1-10d Smooth or Screw
24.3
24.3
24.2
Shank Nail Field Clip)
• a***
1-10d Smooth or Screw
Shank Nail Eave Clip).":•.
19.0
19.0
22*1'
2-10d Smooth or Screw
Shank Nails Field Clip)
35.5
35.5 •,�;,
34,8
2-10d Smooth or Screw
Shank Nails Eave Clip)•
31.9
31.9 '...•.�•
• • •
•
• 0 . . .
•• •• ••
41
Table 5: Attachment Resistance Expressed as a Moment Mr fi►hb **
{
for Two Paddy Adhesive' Set Systems
•
Tile
Tile Application
Mi��i_p Attachment
Profile
Resistance• • • •
Villa 900 Concrete Tile
The Dow Chemical Company TiteBond
26.12
ICP Adhesives Polyset® AH-160 two-
26.13
component foam
FDAIP�Foam Touch N Seal StormBond ''2 Roof
554
Tile Adhesive two-com onent foam
1 See foam adhesive manufacturer's component approval for installation requirements.
2 The Dow Chemical Company TileBond one -component foam, minimum weight per paddy 11.4 grams.
3 ICP Adhesives Polyset® AH-160 two -component foam, minimum weight per paddy 8 grams.
4 DAP Foam Touch N Seal Storm Bond m 2 Roof Tile Adhesive, average weight per paddy 8 grams, two component
foam.
Table 6: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf)
for Single Paddy Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Villa 900 Concrete Tile ICP Adhesives Polysett AH-160 two -component foam
86.615
ICP Adhesives PolysetO AH-160 two -component foam
45.5 6
DAP Foam Touch N Seal StormBond 02 Roof Tile
407
Adhesive
DAP Foam Touch N Seal Storm Bond 02 Roof Tile
708
Adhesive7
MIAMWAr NOA No.: 18-0509.16
•"'+ + Expiration Date: 09/21/21
Approval Date: 06/28/18
Page 5 of 7
5 Large paddy placement
of minimum 54 grams.
6 Medium paddy
placerne2t of minimum 24 grams,
7 Medium paddy
placement of minimum 30 grams,
8 Large add
lacement of minimum 60 grams.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Villa 900 Concrete Tile
Mortar Set'
20.60
Tile-Tite Roof Tile Mortar.
••••
• •
5. LABELING • • •
•• . ••••
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name at?Was detailed below;
or following statement: "Miami -Dade County Product Control Approved". 000006
00••• •
LABEL FOR BORAL VILLA 900 CONCRETE TILE
(LOCATED ON THE UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
T"f1AM1•DADE COUNTY
NOA No.: 18-0509.16
r • Expiration Date: 09/21/21
Approval Date: 06/28/18
Page 6 of 7
Nail holes
PROFILE DRAWING
I/2s
VILLA 900 CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
Over.1" O
��� NOA No.: e: 09/21.16
MIAMt L1ADE COUNTY
Expiration Date: 09/21/2l
Approval Date: 06/28/18
Page 7 of 7
MIAMI•DiADE
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ)......
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County ,Pxedgct ControlSection • • •
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve "gbt to haye thi$ • • • •: •
product or material tested for quality assurance purposes. If this product or material fails to pefLm in the accepted .
manner, the manufacturer will incur the expense of such testing and the AHJ may immediat& revoke, modwy;or ; • • • •
suspend the use of such product or material within their jurisdiction. RER reserves the right 18 tevoke thislatteptanct!; • • •
if it is determined by Miami -Dade County Product Control Section that this product or matertrfalls to mMttlle 00000
•• •• •• • ••••
requirements of the applicable building code. ••
This product is approved as described herein, and has been designed to comply with the Flcp7ida Building Code • •
including the High Velocity Hurricane Zone of the Florida Building Code. 0 0
: • • • • • 0
•
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino.
NOA No.: 17-0614.22
rn Foaoe�111.2,1011411w Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
ROOFING COMPONENT APPROVAL
Catesory: Roofing
Sub-Cateeory: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product
Dimensions
Specification Description
Polystick IR-Xe
65' x 3'3'/8"
ASTM D 1970 A fine granular/sand top surface self -adhering, APP
Manufacturing
Or 65' x 3'
polymer modified, fiberglass reinforced, bituminous
Location #1 & #2
60 mils thick
sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
Polystick Dual Pro
61' x 3'3-3/a"
TAS 103 and A rubberized asphalt self-adhtrirlg, glass-rlber✓polyest, • • • •
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Desi'tt$14s a • •
.
Location #2
• . .. . ..... .
metal roofing and roof the un � � • .yment. •
Polystick Tile Pro
61' x 3'3-3/8"
TAS 103 and A rubberized asphalt self-adhpMV,, glass-�berftlyester •
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membi'Ade. Desightd'as a meth:'O.
Location #2
roofing and roof the underlayme 0: • • 0
s o
Polystick TU Max
65'8" x 3'3-3/8"
TAS 103 and A rubberized asphalt self-ad*ThVZ)olyester feinforced •,
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Dgsign.ea as a $ roof the
Location # 1 & #2
underlayment. • • • • • • • • •
.. ..
Polystick TU P
32'10" x 3'33/$"
TAS 103 and A rubberized asphalt waterproofing membr'aht,•glass-
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a tile roof underlayment.
Polystick TU Plus
65' x 3'3 '/a"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing
roofing and roof tile underlayment.
Location #1 & #2
Polystick MTS
65'8" x 3'33/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polystick NITS Plus
65'8" x T3-3/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G
32'10" x 3'3 %"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Aaency
Test Identifier
Test Name/Report
Date
Trinity ERD
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P33370.04.11
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.10.11
TAS 110/ASTM D4798 & D1970
•19/19/11
P40390.08.12-2
ASTM D 1623
. . 0540`7/12
P37590.07.13-1
ASTM D6164 '..'
.... : 0
.0702/13 .'
P45270.05.14
TAS 103, TAS 110 & ASTN'1•E ff 3
' • 842/14 ......
P46520.10.14
ASTM D 1623 ......
10/03/14 ; ;
P44360.10.14
TAS 103 & TAS 110OO'.
• • • •
.'1VQ7/14
P43290.10.14
ASTM D 1970 & TAS NO•
•1W17/14 ••:��.
PLYG-SC 10130.06.16-3
TAS 103 & TAS l 1p• •
• • Q6 • •
PLYG-10130.06.16-1
ASTM D1970 & TAS.l.14..
06/27/16 .•
PRI Asphalt Technologies
PUSA-035-02-01
TAS 103
; • C429/06 � � � � •
PUSA-055-02-02
TAS 103 •..'
1u10/07 ; • • • •;
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
'.11.706/09
Momentum Technologies, Inc.
JX20117A
TAS 103/ASTM D4798 & G 15 5
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G 15 5
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G 15 5
02/18/10
DX23D8A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
MIAMFDAD; A41A Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane:
Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
Surfacing:
See General Limitations Below.
Deck Type 1:
Wood, non-insuate . . ....
......
Deck Description:
Min. 19/32" plywood or wood plank '. •
...... •
• •; •
System Type E(2):
Anchor sheet mechanically fastened to deck, membrane adhered • • • • •
.... ....
• •
. .
Anchor/Base Sheet:
One or more plies of ASTM D 226 Type II or ASTM D 2626. •.. •
�.' • • •
•
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a!Wit$um 4 ; he$d lap. (fdf' • •
.. .. .. .
base sheet only)
......
Membrane:
Elastoflex S6 G, hot asphalt applied
.. •...
Surfacing:
•••..•
See General Limitations Below. � �
� • •
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
.000
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly eurrent Product Contror 0
• • • ..
Notice o Acceptance. 0 0 0 0 0
.
. .
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The-ila9lring tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layptbf%plysti�k shaQ be - -
.... .
applied over the underlayment. 000 00:00
...... .0 00000
.. .. •• . •....•
GENERAL LIMITATIONS: ......
1. Fire classification is not part of this acceptance. :...:. 0 � � 0 "
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTy§ Plus may be0 so
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ez osure Limitations (Days)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
•
MIAMFDA RIYAVJ TY Expiration Date: 09/13/21 ® Approval Date: 07/06/17
Page 5 of 8
Rule 61 G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystick
System (U)
Profile
MTS
S6 G
TU P, Tile Pro,
TU Max
MTS Plus
MT$ Ptds with
Dual Pro
. •
'I•I? AUS
Flat Tile
Prohibited
4:12
6:12
6:12
5:1.2P • • •
•6. 2►
without battens
000000
•
Profiled
Prohibited
4:12
6:12
6:12
4:1Z •' •.
O-v1%
Tile
without battens
The above slope limitations can be exceeded only by using battens in accordance witlffhe•Approved Tile'Syste" • •; •
Notice of Acceptance and applicable Florida Building Code requirements. When battens ar; required,• they shall •
be utilized during loading and installation of tiles. • • • • • •
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid Orgppipg of • • •
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure"two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
d
a
0
rn
N
POL` nCKYU Rue
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMl3Pv1QE%
. . .... ......
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPE6VIC•APPL1eXt1ONS. • •
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECO1V VYMATIONS. ,
•.....
1. Polyglass does accept the direct application of Polystick underlayment membranes to �+ooclaecks. sk"al?ers are....
cautioned to refer to applicable local building codes prior to direct deck installation toweilsurg this is Kmtptable• •: • •
Please also refer to applicable Product Data Sheets of the corresponding products. •' • • • • • • • • • •
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edie staid as per Polyglass ....;,
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" meta:aisvis
required in Miami -Dade County or simplex type nail as otherwise allowable in other region, at a ipi nim um rat;**"*:
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area paralMadar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6'/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
0000
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPEMIC•APPLjCA:1QNS.
'.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOn.V.one DATIONS. •
•
•....•
.•.• ..••
• .
END OF THIS ACCEPTANCE '••• ••••
••�••
...... ....
.....
•• •• •• •
••••••
•
•••••• •
•
••••••
• • • • • •
• •
• • •
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8
MIAMI-DADE COUNTY
Ml® PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
ICP Adhesives and Sealants, Inc.
12505 NW 44" Street
Coral Springs, FL. 33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County PtQduct tbfittUl Sect?W •; -
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve to right to hale Wis product go
or material tested for quality assurance purposes. If this product or material fails to perfor 7iF9 accepted manner, lie
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, "qAj�, or s4sp; pd the i"-o
of such product or material within their jurisdiction. RER reserves the right to revft.&i% acccU44c.d, if its"•
determined by Miami -Dade County Product Control Section that this product or material fails," meet tha se4uireme9JJ..'
of the applicable building code. •
.. .. .. . ......
This product is approved as described herein, and has been designed to comply with: eMorida Building Code •
including the High Velocity Hurricane Zone of the Florida Building Code. ' • • • •
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product
Dimensions Test
Specifications
ICP Adhesives
N/A TAS 101
Polyset®AH-160
ICP Adhesives Foam
N/A
Dispenser RTF1000
ICP Adhesives ProPack®
N/A
30 & 100
PRODUCTS MANUFACTURED BY OTHERS:
. .
....
......
Product•Heseriptiop • •
•
•
•
......
.. .
......
Two component bane
fqATu.adhesige• • •;
pol;Z*.*
....
....
•••••
.
. ..
Dispensing Equipmen ...
...
. .
......
.. ..
.. .
......
Dispensing Equipment 0
0
....:.
......
.
......
•• •
• ••
• •
. .
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
ProverProverty Test Results
Density ASTM D 1622 1.6 lbs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft2
Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch
Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -400 F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
Closed Cell Content ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
MIAMI•DADECOUNTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Center for Applied Engineering
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
Test Identifier
#94-060
257818-1PA
25-7438-3
25-743 8-4
25-7438-7
25-7492
NB-589-631
9637-92
01-6743-011
01-6739-062b[ 1 ]
7050.02.96-1
P36700.04.12
P39740.02.12
528454-2-1
528454-9-1
528454-10-1
520109-1
520109-2
520109-3
520109-6
520109-7
520191-1
520109-2-1
Test Name/Report
TAS 101
TAS 101
SSTD 11-93
SSTD 11-93
SSTD 11-93
ASTM D 1623
ASTM E 108
ASTME 108
••••••
ASTM E 84
•' •' • •
••••••
TAS 114
ASTM D 1623
•��••�
TAS 101
••.•••
TAS 123
TAS 101
••••
TAS 101
TAS 101
Date
04/08/94
12/16/96
10/25/95
11 /02/95
12/ 12/95
02/01 /94
UZ/3 3
f 1*/d i/44
01/16/95
01AV96
02/2j/12
• • .. • •
1.0/2&98
. .
12/28/98
03/02/99
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the au�liority Navin
pP Y PP PP ... .....
. .
jurisdiction. • � • • � � •
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is feLftofeti beforeoappiicatiori• • • •
of any adhesive. The mix ratio between the "A" component and the "B" component AM bVinaintainetl between....
1.0-1.15 (A): 1.0 (B).
.... .... . .
.... .... .....
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser-RTF4000 or•ICa ..:..'
Adhesives ProPack® 30 & 100 dispensing equipment only. • • • • • • • • • • • • •
......
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 0 0 0 0 : •
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minujes 4ftgr ICP•Adhesives •
Polyset® AH-160 has been dispensed. " ' •
....
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at.
•
0000
overlap
.' ....
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal-' •
• 17 grams ver bead '
edge) 20-25 sq. inches each
•
• • •
bead
• ... .... ...
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
• • •34 gramun$•c�er pan, . •
. . . . ......
LABELING: •
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of t'he:..'
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL ## 1
Nall thm"hPlastic Cement Paddy (Ran•ashl"a•)
jahmraqulradl,
lfndrdrymrnt
p
Vol
O'Nums optional
EautCoun•� �" !
�. Fascle
.IrZ Mrrr
Emir Closure
Flail itnrough plastic ctmeM
When required?
_5 21n.wld•
Sei 5opllonal
to
Paddy 411rneath Uri
€ave closura
Fascia
n,mgt F plepllc r►r rtPt PiddM Iarn•rlkTilrl
(Wh
tsMen rogWmtl
ro;n. K
�t2in.wide
Battens
Gisftnal
ErveCourse .'" pastLa
Weeplhole
in. i `� Eave closure
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
rare
. • .... •ara•a
•
•• • area
a • • •
•
Medium Profile / Double J%WTile 000000 err••
••
area rare rear•
• •
0000961 •• „ area•
1. Starting at the eave courses apy a ralonit fum 2
(50.8 mm) x 10" (254 mm) x 1" (25.4emmTfoama
paddy onto the underlalmefit Dositigped V shown...:.
under the pan portion of the tle clostgf tfie •
overlock of the tile beinOR Piet.: • a : "
0000
2. Continue in same manner. Insure approximately 17
(109.7 cmZ) — 23 (148.4 cm') square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm') — 23 (148.4 cm') square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cmZ)
— 23 (148.4 cm') square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam pa4d)6 onto the
underlayment positioned a; shown undeie*x- • • • • • •
strengthening rib closest to flte oderloclsbfshe,tile •,
being set. "'i" " '
.•
•
3. Continue in same manner.'G;ZcPapprox""rp.�.j*•aly 10of; •
(64.5 cmZ) - 12 (77.4 cmZ)S � inch ad4eAve * •; 0 0 •
contact with the underside•af "'tile.
•..... •
00
Medium Profile / Double Pad Tild. • ,....,
.. . . .. • .
• •
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cmZ) —
23 (148.4 cm') square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cmZ) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
Hall thirouo prastk c•
(Aen ragulr•d)
P+ddY lBrrvNNhTi1.Y
ti
uha..►y�.•.t
7 W
k
eaten o0d onal
Eeve Course
ascia
► W"Oph•i«
10 in 2 M.
`*
[Wff doswe
brip.dya
APPROVED
High Profile / Single Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cmZ) —
23 (148.4 cmZ) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2100.8mm)
x 7" (177.8 mm) x 1" (25.1 mrpr Foam pa&dl onto tho....
underlayment positioned as Sirovt under AT%an •
portion of the tile closest to 1?MerlockVf tht the • •' • • •
being set. :....:
.... .... . .
.... .... .....
3. Continue in same manner. jjijW,approxjWjely 17" • •••
(109.7 cm') - 19 (122.6 cni 4%g4lre inc%4dh*ive .. • • • •
contact with the underside"f tiw4tile.
. . . . ......
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
tail through plastic cement Paddy (between tiles)
(when required),
Battensoptiona)
' paddy lunder tile)
single paddy
ontopott€le ,3
s ),spas
Un a7
Single paddy
an undertaYmeot 2 x 41n. `-•�.
`f 2 in. sda
Eave Closure
FlattLaw Progle Tile
Nafl through plastic eernent Single paddy under tile
Iwhen required)
Paddy lbetween tiles)
Battens Paddy lunder tile),
optional
r3
S paddy
pofttle
L
x4in. x41n.ti-.*�
Single paddy on
undedayment
tOEn. '��,21n.
Eave Closure
Eave Course Fascia
Medium PronleTne
On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the Overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in (109.7-148.4 cm2) of
adhesive contact with the underside of the tile
•...
Apply a 4" (101.6 mm) x%0'0(41-04.6 e 1; (25.4• • • •
mm) foam paddy onto the Witleflayment jxst below•
•
.•.•.
the second course line positioned foaiupWld�y •
under the strengthening rfi TV flat tileMi0ander the....
pan portion of the tile, cl"et to the un'd' Npk for- •...'
the second course tile toJw.4Vtalled. )•nsure • • • • •.
approximately 8-9 in2 OZ .6 58:1 em2) of�adhesive •.
contact with the underside of*the tile. •
....
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
Nail through Plastic ce Single paddy under ale
{When required)
Paddy (between ales)
Battens
optional tt
Paddy (under tile)
d w
onundertaymere�;
a x t rn.
2 x 4 in.
1
�
sbxpe
on
top) ale
O
Eave Course
Fascia
Weephole
loin. 2 (n.
Eave closure
10001
Drip edge
High ProfllaTlra
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/o"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) - 11 (71cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm2) - 9 (58.1 cm2) square inch
adhesive contact with the underside of the tile at
the head of the tile. Contigue in same u1fi11CL.
gooses • g '
••eggs
•
see* see**
•oe•g• •eggs
g
•• g• • • • •
Vov: go
•
g o.e e • • e090*
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
t) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications
in contact with the pan tile. when required)
2) Turn covers upside down. Place adhesive in
to t In. from outside edge of cover tile.
Then install the tile. Ensure 20 to
25 sq. in. contact area. 1No
Underlayment
�illr o
0
Eave closuri
(motor shown)
Fascia
Remove top portion of the eave course cover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at rave line.
Two Piece Barrel - High Profile Tile
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two �n
courses up toward the r idge. insure • • • � e
approximately 65 (419.4,om )r 70 (45 j aq cm2) ""; •
square inch adhesive cdrRarwith th%r Mc:side
ee.e
.e
of the pan tile. ease.. ,
e..e •
. eeee ..eeee
eeee' • • •
3. Turn covers upside doyvp�lx.posing t17Atieaersida..
of the tile. Apply a mhaimyrpI" (2SA!0fq) x 10&'••..'
(254 mm) bead of adhesiaw djrectly on th6 inner • .....
e
edge of each side of the cojv* tile. eave •
approximately 3/4" (IV mrro) to 1"j25.4mm) �"1"%
from the outside edge dAL4ile, inward„ free o2 • e..:
foam to allow for expansion. 0000
Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cmZ) square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11