Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ELC-19-1862
Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 1 8 I�� �Ui�lrn Issue Date: 08/13/2019 Location Address Parcel Number 11300 NE 2ND AVE WEBER HALL, Miami Shores, FL 1121360000050 33161 rnntnr tc Permit NO.: ELC-08-19-1862 Permit Type: Electrical - Commercial Work Classification Alteration Permit -Status: Approved Expiration: 02/10/2020 BARRY UNIVERSITY INC Owner 11300 NE 2 AVE, MIAMI SHORES, FL 331616628 Business: 3058993995 JYAO@BARRY.EDU Mobile: 3054957544 C DAVIS ELECTRIC COMPANY, INC Contractor CHARLES DAVIS Business: 9544324334 Inspection Requests: Description: ELECTRICAL FOR FIRE ALARM SYSTEM WEBER HALL Valuation: $ 9,000.00 305-762-4949 Total Sq Feet: 45,466.00 Fees Amount Application Fee - Other $50.00 CCF $5.40 DBPR Fee $4.05 DCA Fee $2.70 Education Surcharge $1.80 Permit Fee $220.00 Scanning Fee $18.00 Technology Fee $6.75 Total: $308.70 Payments Date Paid Amt Paid Total Fees $308.70 Credit Card 08/13/2019 $258.70 Credit Card 08/13/2019 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above nam ftontractor to do the work stated. 7— LIB; ►� Fe�►q Authorized Signature: Owner / Applicant / Contractor / Date August 13, 2019 Page 2 of 2 BUILDING PERMIT APPLICATION Miami Shores Village R1EcE1VFfD Building Department AU 13 2019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 BY:,//,\-Aj INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 Master Permit No. CC-12-18-3721 Sub Permit Nol!-Q-"`d F,y BUILDING 0 ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL [—]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 11300 NE 2nd Ave, Weber Hall City: Miami Shores County: Miami Dade Zip: Folio/Parcel#:1121360000050 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Barry University Phone#: 305-981-1157 Address: 11300 NE 2nd Ave City: Miami Shores State: FL Zip: 33161 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: C. DAVIS ELECTRIC CO. INC. Phone#: 954-432-4334 Address: 1701 SW 100 TERRACE City: M I RAMAR State: FL Zip: 33025 Qualifier Name; CHARLES E. DAVIS JR. Phone#: 954-275-6004 State Certification or Registration #: EC0001 038 Certificate of Competency #: DESIGNER: Architect/Engineer: Cannon Design Phone#: 703-907-2339 Address: 1560 Wilson Boulevard, Suite 200 City: Arlington State: VA Zip: 22209 Value of Work for this Permit: $ 9, OOO Square/Linear Footage of Work: 45,466 Type of Work: ❑ Addition ❑■ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: ELECTRICAL FOR FIRE ALARM SYSTEM: Renovation to Weber Hall Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ `l TOTAL FEE NOW DUE $ (Rev1sed02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City N/A State Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature 44-oyl &-Jon OWNER or AGENT The foregoing instrument was acknowledged before me this 1 ) day of V /,S 20 4 by who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sig Print: 1H1 Seal: APPROVED BY (Revised02/24/2014) Nohty P*k -110 of. F*Ida j�CO�lnl{�Nal • I F MSZ4S my Comic lilso i4.,iiiiN Signature C/STRACTOR The foregoing instrument was acknowledged before me this 12 day of AUGUST 20 19 by CHARLES E. DAVIS JR. who personally known as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Print: DOUGL S BERNARD Seal: "`"" DOUGLAS E. BERNARD, SR, Commission # GG 345175 •, EXPIres u Bonded ThruTmy Fain Insurenoe 600.365.7018 ################################################################### Plans Examiner Structural Review Zoning Clerk �J NOTI Fill E R� by Honeywell GENERAL The AFP-300 and AFP-400 are compact, cost-effective, in- telligent fire alarm control panels with a total capacity of up to 563 points and an extensive list of powerful features. The AFP-300/400 integrates conventional output circuits, such as notification, telephone, and speakers, with the in- telligent features of one or two signaling line circuits (SLC) and 198 or 396 intelligent/addressable points. FEATURES • One loop (AFP-300) or two loops (AFP-400) Style 4, 6 or 7. • 198 intelligent devices per loop (99 intelligent detec- tors and 99 intelligent modules). • 396 intelligent device capacity on the AFP-400; 198 on the AFP-300. • VIEW®, HARSH TM, Advanced Multi -Sensor (AMS) op- tions. • Up to 68 internal circuits/relays, plus 99 programmable zone output relays for a total capacity of 563 points. • Four integral Notification Appliance (signal) Circuits (NACs), Style Z or Y (Class A or 6). • 6.0 A power supply, plus 6.0 A expanders. • NACs may be programmed for Steady, March Time, Temporal, California code. or Canadian Two -Stage. • Modified California code, pulsed on time. • Tornado Warning activates different Notification Appli- ance Circuit code. • Alarm, Trouble, Supervisory, and Security relays, stan- dard. • Peer -to -peer network -ready. • Intelligent features: ✓ Manual sensitivity adjustment — 9 levels. ✓ Pre -alarm intelligent sensing — 9 levels. ✓ Day/Night automatic sensitivity adjustment. ✓ Drift compensation. ✓ Multi -detector algorithm involves nearby detectors in alarm decision. ✓ Auto detector test (meets NFPA 72). ✓ Maintenance alert (two levels). ✓ Self -optimizing pre -alarm adjusts pre -alarm level to environment automatically. ✓ Activate local sounder base on pre -alarm. ✓ LED blink control for sleeping areas. ✓ Automatic device type check. ✓ Trouble after 20 detector verifications. • Releasing features: ✓ Ten independent hazards. ✓ Sophisticated cross -zone (three options). ✓ Delay timer and Discharge timers (adjustable). ✓ Abort (four options). October 31. 2005 DN-5262 • A-103 AFP-300 and AFP-400 Analog Fire Panels Section: Intelligent Fire Alarm Control Panels U . ■ California U State Fire �Marsh61 717t-M: 8:182 .... LISTED CS118/733 " 71j�* Q 181 '• .•.... .• . ...... S635 •• City Of • M EA 91ir 90 :....' 17-96-E (AFP-400) CLAY S 1 •1291 E• .: • • • 17-96 E Vol. 11 (AF00) AP CLAD • � V 729E• • • . e • City of DENVER (AFP-400) • Sensitivity windows: ✓ ION — 0.5 to 2.5%/foot obscuration. ✓ PHOTO — 0.5 to 2.35%/foot obscuration. ✓ MULTI -SENSOR — 0.71 to 4.0%/foot obscuration. ✓ VIEW® — 0.03 to 1.0%/foot obscuration. • Low-pressure COZ support: ✓ Expanded soak timer — 0 to 9999 seconds. ✓ Manual release delay (10 seconds) type ID. ✓ "Second shot" monitor module type ID. ✓ Triple -coded notification circuit type ID. • Voice and telephone features: ✓ Solid state message generation. ✓ Hard -wired voice control module options (single - address mode modules). HARSHTm and NOTI•FIRE•NETTm are trademarks;VeriFire®, VIEW® and NOTIFIER® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. This document is not intended to be used for installation purposes. We try to keep our 1S0 �oo� product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 �J N OT I F I E W EM6YMEE1IING A MIANEACIDIIIIIING by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 Q B A L I T Y SYSTEMS -5 • 1 31 05 — Facie 1 of 1 C ✓ Distributed voice options (XP transponders). ✓ Firefighter telephone option. ✓ 30- to 120-watt high -efficiency amplifier. ✓ Backup tone generator and amplifier option. ✓ Dual channel option. • Telephone control module type ID. • Optional IIDACT, 396-channel digital alarm communi- cator transmitter with AC fail delay. • 80-character displays (up to 32) for remote annunciation. • • • • • AC$ �1�Qnciatorg (EIAi485), including LDM custom. '. Tworwire detector interlace provides compatibility with .... mg%i wafiufacturo" detectors for retrofit applications. Integral printer tnterfece (80-column and 40-column • • • • printers).. 0 0 * • • • • • • Integral 80-charaCtel' ECD display, backlit (2 lines x 40 ••••• characters). �••�•• •; • • • • Fi;d-pfdgrammaI1I8 ot1'panel or on PC, with program • • check, compare; trLMate. FugL\40TY k4ypad behind flip -down door. :....: Autoprogrammin and ;Valk Test. .. .. • Ider�iji:§two devices set to the same address. • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm -only file. • Programmable waterflow or supervisory selection per point. • Alarm Verification selection per point, with tally. • Verification Trouble counter. Trouble indication after a detector verifies 20 times. • Programmable Positive Alarm Sequence (PAS) Presignal per NFPA 72. • Silence inhibit and Auto Silence timer options. • Programmable non -alarm points for lower priority func- tions. • Remote ACK / Silence / Reset / Drill via addressable modules. • Maintenance Reports may be sorted via PC by compen- sation value (dirty detector), peak alarm value, or address. • Automatic time control functions, with holiday exceptions. • Dual rate charger for up to 90 hours of standby power. • Rapid poll algorithm for manual stations. Responds to alarm/activation in less than three seconds. • SLC loop maximum length 10,000 feet (3,048 m) @ 12 AWG (3.31 mm2). • Surface Mount Technology (SMT) electronics. • High-speed RISC 16-bit microprocessor. • Extensive built-in transient protection. Page 2 of 10 — DN-5262 • 10/31/05 SAMPLE SYSTEM BLOCK DIAGRAM UP 0 0 0 ®❑ o Do 0 ❑ TO ❑ ❑ ❑ ®0 32 o a ❑ o 3 LCD-80 Remote Display/Control RS-485 Up to 68 fully programmable output circuits 0 SLC Intelligent Loop 1 DEVICES 101-1 FSI-851 Ion FSP-8 Photo FST-851 Thermal — — — — — — — — — — - NBG-12LX � oq FMM-1 Fixed t I DC SLC Intelligent Loop 2 DEVICES OO FSP-851T7=7L FST-851R FAPT-851 Photo/ Thermal Advanced — — — — — — — — — — • NBG-12LX FMM-1 Thermal Multi-Sensor IDC RS-485 640 annunciator/control points AFP-400 shown in CAB-4 with voice alarm system RS-232 tE i o FCM-1 k—.==— XP Transponder NAC FC 1M ( LfW® mo® XP Transponder NAC I — o 0 0 0 �� � i •� i � i i i ° �� � i •�' i � i � i I o 0 i i ■ i � i I o �,'_� • ■ ACM-8R I° ° Relay Control ACMIAEM-16AT LED Annunciator LDM-32 Custom Graphics Optional 396 channel UDACT Universal Digital Alarm Communicator Transmitter Dual phone lines jo to Central Station RS-232 Terminal • • • • • • • • • • • • PRN Printer • • . • . . • • • • CRT-2 Termin2O • • • • • • • ! • • • • • • • • • • 000 ••• • • • • ••• • • • • • • • • • • • • • .. •• • • • •• •• The CPU-300/400 EIA-232 EIA-485 Port SLC Loop #1 EIA-232 Terminal Port "Terminal Mode" (Style 4, 6, or 7) EIA-485 Port SLC Loop #2 (AFP-400 only) Printer Port � \ / _ (Style 4,6, or 7) •••••• •••• • • • Y• • • • • • • • • • Slide-ir; L�tlel •••••• •••••• ••••• • • •••••• •• •• • • •• •••••• • • • • • • • •• • Esl F M ro4Ew 4LPW MBwI•gw 8E111W1Y 1N01•lF •uw4 � w4 crarwr 8tf0�e1/�81LENCE VeYE won i5 m LAIi lE4E 0000000000 0000000000 ® 000000000 _] 00000000C Alto A U0r__�■ ice_■:,. '■ The MPS-400 Main Power Supply 2 non-resettable Resettable 24 VDC circuits 24 VDC @ rated 1.25 amps 125 amps` eachY98.,,., \ AC Power 120/240 VAC_ = i t;7� I (Field Selectable) Battery (12-60 A.H.) 80-Character (2 x 40) Back -Lit LCD Display �- Status LED's --- Control Switches Programming Keypad F— Flip -Down Door (covers the programming keypad) Form-C Alarm, Trouble, Supervisory, and Security contacts. (3 amps @ 30 VDC) (Note: Supervisory and Security contacts can be converted to alarm contacts.) NAC or Releasing circuits 1 & 2. Class A or Class B, re mmmm mmmm 24 VDC @ 2.5 amps each.* p,9 h im ti y =ems K;pI� NAC or Releasing Circuits 3 & 4. �g a Class A or B, 24 ®® VDC @ 2.5 amps each.` ti Status/Trouble LEDs • ij i 'The MPS-400 is a 6 amp =1a power supply. Total power, including internal modules, :?? cannot exceed 6 amps. i+ 0. ® ® 6 UZC Coder Input � _ Door Tamper Switch (STS-200) Meter Module Option (MPM-2) Page 4 of 10 — DN-5262 • 10/31/05 Transmitter module (4XTM connector). Intelligent Sensing Intelligent Sensing is a set of software algorithms that provide the AFP-300/400 with industry -leading smoke detection capability. The development of these sophisticated algorithms are made possible by the close coop- eration between Notifier and System Sensor, the world leaders in fire detection and alarm technology. These complex algorithms require many calculations on each reading of each detector, and are made possible by the very high speed microcomputer used by the AFP-300/400 (16-bit RISC Reduced Instruction Set Computer). 0 Drift Compensation and Smoothing. These al- gorithms (U.S. patent pending) identify and compensate for long-term changes in the analog readings from each smoke sensor. Long-term changes are usually caused Analog by dust accumulation inside the smoke chamber. Drift Reading compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance re- quirements by allowing the system to automatically per- form the periodic sensitivity measurements required by NFPA. Smoothing filters are also provided by software to remove transient noise signals, usually caused by elec- trical interference. Different smoothing algorithms are used, depending on the sensitivity selection of each de- tector. © Maintenance Warnings. When the drift compensation performed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value, usually indicative of a hardware problem in the detector; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. The Maintenance Alert level allows maintenance before the performance of the device is compromised. © Sensitivity Adjust. Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre - alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre -alarm operation can be latching or self - restoring, and can be used to activate special control functions that are a subset of the alarm control program. 0 Self -Optimizing Pre -Alarm. Each detector may be set for "Self -Optimizing" pre -alarm. In this special mode, the detec- tor "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre -alarm level just above these normal peaks. This allows extremely sensitive pre -alarm capability with reasonable protection against non -fire signals. V • • • •••• •••••• • Alarm Level • • • • • • .••..• • • •..• • • • • wnn compensar • • • .. • • • trod smpo,hirg • Time f dayS) : �•..�.a s,.wmf . •• • • .. • DIRTY Maintenance Urgent —►; Maintenance Alert I Acceptable Range l' Low Chamber � Reading —►' Low Value Awacs2.wmf PrealarmpThreshold nt�rifl6'`ri�f-l4.h'. Y S L�•f'nt lif Normal Threshold —� Awacs° wmf ©Cooperating Multi -Detector Sensing. A feature of Time (days) intelligent sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre -alarm o j decisions. Using logic algorithms, each sensor can include up f= Q Alarm to two other sensors in its decision. Without statistical sacrifice ¢ i— — — — — — — — — —in the ability to resist false alarms, it allows a sensor to increase U' Combined its sensitivity to actual smoke by a factor of almost 2 to 1. Multi- 0 3 Sensors detector sensing also allows the combination of ionization with w photoelectric technology in reaching an alarm decision. p Time (minutes) 5262aw5 wmf DN-5262 • 10/31/05 — Page 5 of 10 FIELD PROGRAMMING OPTIONS AUTOPROGRAM Autoprogram is a timesaving feature of the 3001400. It is a AUTOPROGRAM PLEASE WAIT special software routine that allows the 300/400 to "learn" what devices are physically connected and automatically load them in the program with default values for all param- eters. Requiring less than 30 seconds to run, this routine allows the user to have almost immediate fire protection in L 1:80 DE"I'S, 15 MOOS 1.2:93 Dl I'S, 35 MODS a new installation, even if only a portion of the detectors PANEL OU'l'11U"rS:24 BELLS: 04 are inslailet.The routine will find all intelligent detectors and '; • • • • modul4sf, tAd presept tliem:o the installer for edit of the de- • • fault Q%dh%,,plectior%, ift8sired. If a device is found that already exists in memory, autoprogram skips over that device (only new • • • • • • devices of fnissing 6&:dAlare presented to the installer). Often the installer will perform autoprogram as a first step in a new • • • • installation, then uplos(ONieprlogram into a PC to add all custom labels and other information, then download from the PC to the 300/400. *••.•• • • KEYPADFF20GRA99DIT ••••• The • • has th;••d••ve feature of full program cre- VOW ?�� 4� p g EN"TER PROG UK STA"I PASSWORD, "1'I [EN • • ation and edit capsb lii4yfj(" the front panel keypad, while EN-rER (ESCAPE -1-0 ABOR"l') ..... continuing to protwda fira protection. The architecture • • • •' • of thes3QDMA software is such that each point entry carries ;••••; its own program, inrl%ing:ontrol-by-event links to other • • point .•R1 lows tHb rb ram to be entered with inde en- 2— � 1s � p p o=CLR l=Au'ro —1 olN'r 3=PAsswD a=MEssAGE dent per"t segments, while the 300/400 simultaneously 5=ZONES 6=SP1, FUNCT 7=SYSTEM 8=CIIECK PRG monitors other (already installed) points for alarm conditions. In addition to avoiding system shutdown, program edit from the panel keypad has the advantage of not requiring an on -site PC. This can save significant installation time for minor program changes. The 300/400 site -specific program is password protected, and all information is stored in nonvolatile memory. Menu "trees" are provided to lead the trained installer through the program steps without the necessity to refer to the programming manual. VeriFire® Software PC software is available for off-line programming and test utility that can greatly reduce installation programming time, and increase confidence in the site -specific software. VeriFire® is a Windows® -based program providing techno- logically advanced capabilities to aid the installer. The in- staller may create the entire program for the 300/400 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. The program includes error checks for common program- ming mistakes, such as an input point that does not activate any outputs, or an output point that is not linked to any inputs. It also includes a simulation routine that will list all of the output points that are activated by a particular input point (alternatively, it will list all the input points that are linked to a particular output). Although this does not eliminate on -site testing, it greatly increases confidence in the final installa- tion. For example, a 200-input and 100-output point system, without using the software, could require 20,000 test ob- servations to verify all possible 1/0 links. The software includes a compare routine, pictured at right, that can also greatly help the installer. When a new program is created, it may be compared with a previous version and differences are highlighted. If the program is modified from the panel keypad, it may be uploaded into the PC, and com- pared with the previous version stored on disk. The identifi- cation of program differences greatly helps the installer in testing the installation. NFPA 72 requires that reacceptance test of a fire alarm system be performed on 100% of all points that are "known" to be modified. The software allows the installer to determine the exact points that are changed. 5262-2.ef System Parameters. S'M Ha M...—: ftMi Y00R W OIAR. �1STOM MESSAGE HERE S, a Tom¢ eSA Silers 1A T—f0.T00 aE pp Auto Si . T" (0.S06S00 st F: A v.acrm T�pw•t U Sq. G: J Led ert Lo _ ,. L p T a W 0 a 000 M M = =_ I a am M a Aiwaat•amn � Page 6 of 10 — DN-5262 • 10/31/05 BASIC EQUIPMENT PACKAGES There are two packages available to configure an AFP-300 or 400 system. The standard model, BE-300 or BE-400, is designed to mount in a NOTIFIER full-sized cabinet in the CAB-3/4 Series. The BE-300AA or BE-400AA is a minia- ture package designed for a smaller cabinet, the CAB- 400AA. Order one of the following BE packages: BE-400: Base Equipment includes the CPU (2 loops) module (CPU-400), an 80-character display, program- ming keypad, MPS-400 main power supply, installation instructions, chassis and required hardware. Order CAB-3/4 Series cabinet separately. BE-400AA: Base Equipment for use with CAB-400AA min cabinet. It is similar to BE-400 but for use in smaller cabinet. Includes MPS-40ORB and transformers. Supports one output option module. Order CAB-400AA cabinet separately. BE-300: Base Equipment includes the CPU (1loop) module (CPU-300), an 80-character display, program- ming keypad, MPS-400 main power supply, installation instructions, chassis and required hardware. Order CAB-3/4 Series cabinet separately. BE-300AA: Base Equipment for use with CAB-400AA mini cabinet. It is similar to BE-300 but for use in smaller cabinet. Includes MPS-40ORB and transformers. Supports one output option module. Order CAB-400AA cabinet separately. CAB-3/4 Series: The AFP-300/400 utilizes CAB-3/4 Series cabinets. See data sheets DN-3549 and DN- 6857. SYSTEM MODULES The AFP-300/400 includes the ability to communicate with up to 8 conventional modules each with up to 8 circuits. Any mix of notification, relay, speaker, or telephone may be used. Choose any combination of up to eight output modules: ICM/ICE, CRM/CRE, DCM-4 or VCMNCE. ICM-4: Notification Appliance Circuit Module, provides four Style Y or Style Z alarm Notification Appliance Circuits. Maximum signaling current is 3.0 amps per circuit or 6.0 amps per module, subject to power supply limitations (includes auxiliary power harness, ELRs and slide -in labels). �' Includes ON/OFF controls and ON/OFF LEDs See ICM-4 data sheet DN-0010. ICE-4: Notification Appliance Circuit -Expander, expands ICM-4 to provide a total of eight (8) Style Y or Style Z alarm Notification Appliance Circuits. Circuit ratings are same as ICM-4. (Maximum of one per ICM-4.) May also be used to add four Notification Appliance Circuits to VCM-4. See ICE-4 data sheet DN-0010. o ,_ CRM-4: Control Relay Module, four (4) Form- C relay contacts, rated at 5.0 A, 120 VAC or 28 VDC (resistive) per circuit. Includes manual ON/OFF controls and LEDs. 3 See CRM-4 data sheet DN-0461. E �- CRE-4: Control Relay Expander, expands CRM-4 to provide a total of eight (8) Form-C relay contacts. (Maximum of one per CRM-4.) € May also be connected to add four relays to ICM-4, TCM-2, TCM-4, or VCM-4. See CRE-4 data sheet DN-0461. VCM-4: Voice Control Module provides four Style Y or Style Z speaker G circuits, eight manual select switches e and indicators, slide -in labels, and plug- 60; ==3 in terminal blocks. Move jumper to convert to telephone circuits with remote. ring signal and local call -in flash. May be �o expanded to 8 circuits with VCE-4, ICE- 1.00ow- 4, or CRE-4. VCE-4: Voice Control Expande; •"44IM la4isil ®rT1 adds four circuits to V CM- . • • 1��� • • • • • gn� Note: VCM-4 / V6Fisl combina- •C C = e • tion must be 8 spoakP6 c& 8 ®'.: . •. •: • ° hone circuits. ' DCM-4: Dual Ch3rtnV%odule provides four Style TO&OStyle Z Speaker • .... • circuits plus four channel A/80"" relays,, GNot • • • • • expandable. •• •• •a •. •••••• • • OTHER OPTION MObU1_9S • ARM-4: Auxiliary Relay Module; foLW'(J) ' 0•...0 Form-C relays controlled by A •relay • • module (CRM-4 or CRE-4). N.O. contacts •� ` a .�. rated 20 amps, N.C. contacts rated 10 r.;:7 amps at 125 VAC and 30 VDC. Maximum ® W 6 of one for each CRM-4 or CRE-4. See ARM-4 data sheet DN-0461. — VCC-1: Voice Control Center. Provides a variety of user selectable tones on a single channel. Up to two different tones or messages may be selected on a single channel. Also provides optional digital voice message capability and on -site programmable voice messages. Includes Audio Message Generator (AMG-1) microphone, cables, dress panels, and instructions. VTCC-1: Voice/Telephone Control Center. Provides all that the VCC-1 provides plus two-way Fire Fighter's Telephone (FFT-7) capability. IYI. W TCC-1: Telephone Control Center. Provides a stand- p '` alone two-way Fire Fighter's of • telephone (FFT-7S). Includes o s • cables, dress panel and „� ° instructions. ! is �. AMG-E: Audio Message Generator (without micro- phone). Order in addition to VCC-1 or VTCC-1 if two -channel system is required. FFT-7/FFT-7S: Fire Fighter's Telephone control with master handset. AA-30: Audio Amplifier - 30 watts. Switch -mode power. Includes amplifier and audio 3224a30.wmf DN-5262 • 10/31/05 — Page 7 of 10 input supervision, backup input, and automatic switchover, power supply, cables. O 9 DIM 00 oc O m 11 �� 00 00000 O AA-120/AA-100:Audio Amplifier provides up to 120 watts of 25 VRms audio power for the AFP-400. The amplifier contains an integral chassis for mounting to a CAB-133/ -134,-C3/-C4, or-D3/-D4 backbox (consumes one row). Switch -mode power. Includes audio input and amplified ou$&* pervision, backup input, and automatic swildhbler to bVPLjp tore. Order the AA-100 for 70.7 V�es.Syrsjems artd 1&( watts of power. VROM (V;-.' Facto ryprUrgTmed message for installation in AMG-1. Provides up to 24 seconds of evacuation merbsage:on noavoiatireo memory chip. Choose one of many standard messages available. Up tq Aq of th48"Mages may be Ao in%%IIL§& in one AUG.•Itfcludes VROM, instructionselbP installation and operation, a;d writt;n text of • meas�agdo 0 0576vrom.wmf ' ' VRAIW?1! •Fiold-programmed memory to be installed in AM" -?.'Provides up to 24 seconds of field -programmable evacuation message on nonvola- tile memory chip. Message is programmed from microphone or cassette tape. Up to two of these nonvolatile memory chips may 0740vramwmf be installed in one AMG. Includes VRAM and instructions for installation and operation. XPIQ: Intelligent transponder designed for multi -channel applications. See XPIQ data sheet DN-6823. APS-6R: Auxiliary Power Supply aoc (expander). Provides up to 6.0 amperes of regulated power for oam� do e� compatible Notification appliance circuits. Includes battery input and transfer relay, and overcurrent protection. Mounts on one of four positions on a CHS-4L or CHS-4 chassis. See APS-6R data sheet DN- 5952. 5052cov.wmf FCPS-24: The FCPS-24 is a remote 6-amp (4-amp continuous) repeater/power supply. See FCPS-24 data sheet DN-5132. FCPS-2456/-2458: Remote six -amp and eight -amp power supplies. See FCPS-2456/-2458 data sheet DN-6927. UZC-256: Programmable Universal Zone Coder provides positive non -interfering successive zone coding. Microprocessor -controlled, field -programmable from IBM-compatible PCs (requires programming kit). See UZC-256 data sheet DN-3404. LCD-80/LCD-80TM: 80-character, backlit LCD display. Mounts up to 6,000 ft. from panel. Up to 32 per AFP- 400. See LCD-80, LCD-80TM data sheet DN-3198. Page 8 of 10 — DN-5262 • 10/31/05 ACS: Annunciator Control Modules ACM-16AT, AEM-16AT, ACM-32A, and AEM-32A. See ACS data sheet DN-0524. AFM: Annunciator Fixed Modules AFM-16A, AFM-16AT, and AFM-32A. See AFM data sheet DN-0056. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM- R32. See LDM data sheet DN-0551. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. from panel on four wires. See ACM-8R data sheet DN-3558. RPT-485: Repeats EIA-485 over twisted pair or converts to fiber-optic medium. See RPT data sheet DN-4737. XP: The XP Series Transponder provides conventional monitor and control points. See XP data sheet DN-0759. CHS-4: Chassis for mounting up to four APS-6R. CHS-4L: Low -profile four - position Chassis. Mounts two AA-30 amplifiers or one AMG- E and one AA-30. CHS-4M: Expansion Chassis. Mounts up to four modules. Includes Panel), and Expander 3 1„ I �I 526204L.wmf CHS-4, MP-1 (Module Dress Ribbon Cable. DP-1: Blank Dress panel. Provides dead -front panel for o 0 unused tiers or to cover AA- 30, AA-120, or AMG-E. 5262dpi.wmf CAB-4 Series: The CAB-4 Series cabinets are fabricated from 16-gauge steel with unique full -front LEXANO, reverse silk- screened for durability. The cabinet assembly consists of two basic parts: a backbox (SBB-_4), and a locking door (DR-_4 )that may hinge right or left. Cabinets are arranged in four (4) sizes. A through Ej D (B [two-tier] is pictured at right). A trim ring option is available for 5871 cablwmf semi -flush mounting. See CAB-4 Series data sheet DN-6857. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. CAB-400AA: Provides small cabinet for CPU-400 and MPS-400RB. Use with BE-400AA only. Space for one (only) output circuit module plus expander. MPS-400: Power Supply module. The MPS-400 includes 4 Notification Appliance Circuits (NAC) that can connect four Class A (Style Z) or Class B (Style Y) circuits. The NAC also can be used for Releasing applications. Includes four built-in system relays (alarm, trouble, security, and supervisory). For BE-400 replacement only. The MPS400 is included in the BE kits. MPS-40ORB: MPS-400 PC board only. Less transformers and mounting chassis. AGENCY LISTINGS AND APPROVALS See the first page of this catalog sheet for listing agencies and file numbers. These listings and approvals apply to the basic AFP-300 or AFP-400 control panel. In some cases, certain modules may not be listed by certain ap- proval agencies, or listing may be in process. Consult fac- tory for latest listing status. The AFP-300/400 is UL Listed, per Standards 864 (Fire) and 1076 (Burglary). It meets NFPA 72 Local, Auxiliary, Remote Station, Proprietary, and Emergency Voice/Alarm Fire Sys- tem Requirements. SPECIFICATIONS • Primary input power, 120 VAC, 50/60 Hz, 3.0 Amps. • Total output 24 V power— 6.0 A.' • Standard Bell circuits (4) per MPS-400 — 2.5 A each. • Four -wire detector power — 1.25 A. • Two non -reset regulated power outputs — 1.25 A each. • Battery charger range: 12 AH - 60 AH. (Use separate BB-55 cabinet for 55/60 AH batteries.) • Charge high rate: 29.1 V. Float Rate: 27.6 V. Note: The MPS-400 has a total of 6.0 Amps of available power. This is shared by all internal modules and each MPS-400 circuit. SYSTEM CAPACITY: AFP-400 • Intelligent Signaling Line Circuits ..............................2 • Intelligent Detectors ......... ............................ _...............__ .................198 • Addressable monitor/control modules .................................................................................198 • Programmable internal hardware and output circuits (four standard) ...........................68 • Programmable software zones .................. .......... I ..... ... _.... .................................. 99 • Special Programming zones ................................................................................... 14 • Programmable remote relay/annunciator points ..................................................... - ..................... 99 • LCD-80 annunciators per system (observe power) 32 • ACS annunciators per system ... 10 Address x 64 points SYSTEM CAPACITY: AFP-300 • Intelligent Signaling Line Circuits ..............................1 • Intelligent Detectors .. _................_..................................................... 99 • Addressable monitor/control modules ................................................................................... 99 • Programmable internal hardware and output circuits (four standard) ...........................68 • Programmable software zones ................................................................................. 99 • Special Programming zones ............................................................................. 14 • Programmable remote relay/annunciator points ................................................................................... 99 • LCD-80 annunciators per system (observe power) 32 • ACS annunciators per system ... 10 Address x 64 points CONTROLS AND INDICATORS Program Keypad: QWERTY type (keyboard layout). 8 LED indicators: AC Power; Fire Alarm; Pre -Alarm; Secu- rity Alarm; Supervisory Signal; System Trouble, Disabled points, Alarm Silenced. Membrane Switch Controls: Acknowledge/Step; Silence; Evacuate; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long -life LED back- light. DN-5262 • 10/31/05 — Page 9 of 10 COMPATIBLE DEVICES, EIA-232 Port PRN-5: 80-column printer. See DN-6769. PRN-6: 80-column printer. See DN-6956. VS4095/S2: Printer, 40 column, 24 V. Mounted in external backbox. See DN-3260; order from Keltron, Inc. CRT-2: Video display terminal. See DN-3756. NAM-232W: Wire peer -to -peer NOTI•FIRE•NETTM net- work interface module. See DN-5331. NAM-232F: Fiber peer -to -peer NOTI•FIRE•NETTM net- work interface module. See DN-5331. COMPATIBLE DEVICES, RS-485 Port ACS Series: Remote Serial Annunciator/Control systems. See DN-0524. VDU S( Remote LCD display, 80 characters. See DN-6820. •; • • • • LG1 80: Remote •LCD display, 80 characters. See DN-3198. .' LJ)U %esies: Remote custom graphic driver modules. See :....: ACID-8R: Remote relay module, 8 Form-C relays. • • SA.QW,:1558..••••. NIB-96: Network*lnterface Board. See ON-0597. • RPTqi$9# Serie3:. Vei;e`ater, isolator and/or fiber optic mo-dem. See DN-4737. UD;CT:.Univejal'DiQ'tal Alarm Communicator Tvw%" it• ter. See DN-4867. •••• UZrC�25C� Zon; CbVl;P,, up to 256 programmable codes. See DN•3404. .... COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receiver unit of FSB- 200(S) below. See DN-6985. BEAMHRK: Heating kit for use with the reflector of FSB- 200(S) below. See DN-6985. BEAMLRK: Long-range accessory kit, FSB-200(S) below. BEAMMRK: Multi -mount kit, FSB-200(S) below. BEAMSMK: Surface -mount kit, FSB-200(S) below. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-20OS: Intelligent beam smoke detector with integral sensitivity test. See DN-6895. FSI-851: Low -profile ionization detector. See DN-6934. FSP-851: Low -profile photoelectric detector. See DN-6935. FSP-851T: Low -profile photoelectric detector with 135°F (57°C) thermal. See DN-6935. FST-851: Thermal detector 135°F (57°C). See DN-6936. FST-851R: Thermal detector 135°F (57°C) with rate -of -rise. See DN-6936. FST-851H: 190°F (88°C) high -temperature thermal detec- tor. See DN-6936. FSD-751PL: Low -flow photo duct detector with housing. See DN-6955. FSD-751RPL Low -flow photo duct detector with relay and housing. See DN-6955. FAPT-851: Acclimate PIusTM low -profile multi -sensor de- tector. See DN-6937. FSH-751: HARSHTm Hostile Area Smoke Head. See DN-6875. FSL-751: VIEW® laser photo detector, will replace LPX- 751. See DN-6886. LPX-751: Low -profile VIEW® laser photo detector. See DN-5306. NBG-12LX: Addressable pull station, visible LED. See DN-6726. B224RB: Low -profile relay base. B224BI: Isolator base for low -profile detectors. B71OLP: Low -profile base. Standard U.S. style. B501: European -style, 4" (10.16 cm) base. B501 BH: Sounder base, includes B501 base above. FMM-1: Monitor module. See DN-6720. FMM-101: Monitor module, miniature. See DN-6720. FDM-1: Monitor module, dual, two independent Class B cir- cuits. See DN-6720. FZM-1: Monitor module, two -wire smoke detectors. See DN-6720. FCM-1: Control module. See DN-6724. FRM-1: Relay module. See DN-6724. ISO-X: Isolator module. See DN-2243. XP Series: Transponder. See DN-0759. XP5-M: Transponder, five monitor points. See DN-6625. XP5-C: Transponder, five control points or Form-C relays. See DN-6625. XP6-C: Six -circuit supervised control module. See DN-6924. XP6-MA: Six -zone interface module; connects intelligent alarm system to two -wire conventional detection zone. See DN-6925. XP6-R: Six -relay (Form-C) control module. See DN-6926. XP10-M: Ten -input monitor module. See DN-6923. XPIQ: Intelligent quad transponder. See DN-6823. OTHER ACCESSORIES 4XTM: Plug-in Transmitter Module. Provides municipal box and remote station connection. BAT Series: Batteries; the AFP-300/400 battery range is 12 AH to 60 AH. See DN-6933. ROM-AFP400: Panel software upgrade kit. Includes latest factory software (consult factory). BB-55(F): Battery Box (required for 509 AH). Qrder •F" suffix for red cabinet. " ' of ' VeriFire-CD: Programming kit for M* cludes Ca, cable, and instructions. VeriFire-CDUG: Same as VeriFire-CD above excopt.4a0es not include the cable. 0. Other options as listed in previoy§Sgitions. • • 0 00 Page 10 of 10 — DN-5262 • 10/31/05 DN-5262 • 10/31/05 — Page 11 of 10 Altronix' (4L1024UL Series Power Supply Charger .. .�••• Installation Guide Models Include: ••• """ . . .. ...... • AL 1024ULX -Single Output • AL1024ULXPD4 • AL1024ULXPD4CB Four (4) Fused Outputs -Four (4) PTC Outputs • AL 1024ULXPD8 = Eight (8) Fused Outputs • AL 1024ULXPD 16 Sixteen (16) Fused Outputs • AL1024ULXPDSCB Eight (8) PTC Outputs • AL 1024ULXPD 16CB Sixteen (16) PTC Outputs For a red enclosure, add an "R" suffix to the part # e.g. AL 1024ULXPDBR Rev. 111003 Overview: The AL1024ULX is a power supply that converts a I I5VAC / 60Hz input, to a 24VDC regulating output (see specifications below). The ALI024ULX is the base power supply unit for the UL Listed multi -output power supply/charger series: AL I 024ULXPD4, AL I 024ULXPD4CB, AL1024ULXPD8, ALI024ULXPDBCB, AL 1024ULXPD 16, AL 1024ULXPD 16CB (Refer to AL 1024ULX Series Power Supply Configuration Reference Chart below). AL 1024ULX Series Power Supply Configuration Reference Chart: z, s40 J G� • �yA � .. .. ... ..... ul O • • .1024ULX(R) • • • - 1 - - - 10 Califomia S.. Fire FMumaactoryl • . . • • • Marshal Approved UL File # S4707 "'•'; '• ••• UL 1481 UL Listed Standard for Safety for Fire A i,1024ULXBD4 : • : 'FD4UL 4 _ x _ 3.5 U� U� • • • • • • 09 c Protective Signaling Systems. *J.l024VLXVD4C$• P134ULCB 4 x - x 2.5 UI U� ...... c UL 294 Listed for Access Coonn trol System Units. •AL1024ULX$D8 ' 4D8UL 8 - x - 3.5 Ui O see* c "Signal Equipment' AL1024ULXPD8CB PDBULCB 8 x - x 2.5 U� \4>1c Evaluated to CSA Standard C22.2 No.205-M1983 AL1024ULXPD Two 16 - x - 3.5 @ PD8U16 L � AL1024ULXPD16CB Two (2) PDBULCB 16 x - x 2.5 @ U� Do not exceed total output rating of 10 amp per unit. Specifications: Input: • Input 115 VAC / 60Hz, 4.4 amp. Output: • 24VDC output. • 8 amp supply current in non -alarm condition with 10 amp supply current during alarm for Fire Alarm Applications. 10 amp supply current for Access Control Applications. • Filtered and electronically regulated outputs. • Short circuit and thermal overload protection. Battery Backup: • Built-in charger for sealed lead acid or gel type batteries. • Automatic switch over to stand-by battery when AC fails. • Maximum charge current 3.6 amp. • Zero voltage drop when switched over to battery backup. Supervision: • AC fail supervision (form "C" contacts). • Low battery supervision (form "C" contacts). • Battery presence supervision (form "C" contacts). Additional Features: • AC input and DC output LED indicators. • Power supply, enclosure, cam lock and battery leads • All models are available in red enclosure (add an "R" suffix to the part # e.g. AL1024ULXPDBR). - 2 - AL 1024ULXseries Stand-by Specifications (total current shown): Output 15 Min. of Stand-by & 4 hr. of Stand-by & 24 hr. of Stand-by & 60 hr. of Stand-by & 5 Mins. of Alarm 5 Mins. of Alarm 5 Mins. of Alarm 5 Mins. of Alarm 24VDC / 12AH Battery Stand-by = 8 amp Stand-by = 1.5 amp Stand-by = 200mA Stand-by = 100mA Alarm = 10 amp Alarm = 10 amp Alarm = 10 amp Alarm = 10 amp Output 15 Min. of Stand-by & 4 hr. of Stand-by & 24 hr. of Stand-by & 60 hr. of Stand-by & 15 Mins. of Alarm 5 Mins. of Alarm 15 Mins. of Alarm 15 Mins. of Alarm 24VDC / 65AH Battery Stand-by = 8.0 amp Stand-by = 1.5 amp Stand-by = 500mA Alarm = 10 amp Alarm = 10 amp Alarm = 10 amp See battery size calculation worksheet for other batteries (Page 7). Installation Instructions: 0060 Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and'wi"Mll local*.... codes and authorities having jurisdiction. Product is intended for indoor use only. • ••Y••• •• • •••••• CAUTION: De -energize unit prior to servicing. For continued protection "" ' : •...; Fig. 1 against risk of electric shock and fire hazard replace fuses with the same fyrp'e . and rating: Input fuse 10A, 250V, Battery fuse 15A, 32V. 0000 ' • • ; • • • Replace fuse cover before energizing. Do not expose to rain or moisture' • ; • • ; ` „ ; •' • • • Door Wire Strap (from Enclosure to Door) t♦� Battery and AC Supervision Circuit • • • • • (power limited). • • O El 11 O O O- ❑O lG O 1G ��I Oo 115VAC MC wer mains non -power limited power limitedClass —Lead Divider Power Distribution Module(s) Battery connection (non power limited) 12VDC Rechargeable Battery 12VDC Rechargeable Battery (optional) (optional) Keep power limited wiring separate from non -power limited. Use minimum .25" spacing. AL 1024ULXseries L—V - 3 - 1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 7,8). Secure enclosure to earth ground. 2. Secure enclosure to earth ground. Connect AC power (115VAC / 60 Hz to terminals marked [L, G, N] (Fig. 1, pg. 3). Use 14 AWG or larger for all power connections (Battery, DC output, AC input). Use 22 AWG to 18 AWG for power limited circuits (AC Fail/Low Battery reporting). Keep power limited wiring separate from non -power limited wiring (115VAC / 60Hz Input, Battery Wires). Minimum .25" spacing must be provided. 3. Measure output voltage before connecting device. This helps avoid potential damage. When servicing the unit, AC mains should be removed. 4. Connect devices to be powered: a. For ALI024ULX Power Supply connect devices to terminals marked [- DC +] (Fig. 1, pg. 3) • • • • b. For othes Power Distribution Models connect devices to be powered to terminal pairs 1 to 4 marked • • [ 1 P• & W thru 4P & 41i] (Fig. 2A & 2B, pg. 5) or Ito 8 marked [ 1 P & 1 N thru 8P & 8N] (Fig. 3A & 3B, pg. 5) • • cargfglly pbserAng Cbrrect polarity. • • • S' 'For AcCesS'Controt A;Pfitations, batteries are optional. When batteries are not used a loss of AC will result in �..., the loss bf output vo'liig�e When the use of stand-by batteries is desired, they must be lead acid or gel type. 6�: onnA-ap&priat sl0 naling notification devices to terminals marked [AC FAIL & BAT FAIL] (Fig. 1, pg. 3) •• so supervisory. relay ggtpp" • • dote: .0VtWp'used alarm, burglar alarm or access control applications, "AC Fail" relay must be used to •, provide a visual indication of AC power on. .: , 7. Please insure that t1e cokr is secured with the provided Key Lock. .,.... . . . • •, • .• LED Diagnostics: AL1024ULJ& Power Supply Board Red (DC) Green (AC) Power Supply Status ON ON Normal operating condition ON OFF Loss of AC, Stand-by battery supplying power OFF ON No DC output OFF OFF Loss of AC. Discharged or no stand-by battery. No DC output. Terminal Identification: AL1024ULXB - Power Supply Board Terminal Legend Function/Description L, G, N Connect 115VAC to these terminals: L to Hot, N to Neutral, G to ground. - DC + 24VDC @ 8 amp continuous, 10 amp in alarm non -power limited output, 10 amp continuous when batteries are not used. AC FAIL Indicates loss of AC power, e.g. connect to annunciator/alarm panel. Relay normally NO, C, NC energized when AC power is present. Contact rating 1 amp @ 28VDC. AC or brownout fail is reported within One (1) minute of event. To delay reporting of up to 6 hrs., cut "AC delay" jumper and reset power to unit. BAT FAIL Indicates low battery condition, e.g. connect to alarm panel. Relay normally energized NO, C, NC when DC power is present. Contact rating 1 amp @ 28VDC. A removed battery is reported within 1 minute. Battery reconnection is reported within 1 minute. Low battery threshold: @ approximately 21 VDC. + BAT - Stand-by battery connections. Maximum charge rate 3.6 amp. -4- AL 1024ULXseries LED Diagnostics: PDOUPDOLC8/PDBUL/PD8UL0 - Power Distribution Module Green Power Distribution Module Status ON Normal operating condition. OFF No Power Output. Terminal Identification: PDOUPDOLORD8UL/PDBUL0 - Power Distribution Module Terminal Legend Function/ PD4UL/PD4ULCB PD8UL/PD8ULCB Description 1P to 4P 1P to 8P Positive DC power outputs. 1N to 4N 1N to 8N Negative DC power outputs. .•.. Power Distribution Module(s): Fig. 2A Replace fuses with the same type and rating 3.5A, 250V. F1 F2 F3 F4 ® ® §HH ® ® ® LED O 1P 1N 2P 2N 3P 3N 4P 4N KM Fig. 2B .••. . • • ••••.• F1 F2 F3 :.•:.: F4 Jj • • • IVI • • ® ® ® ® ® ® ® ® lED O 1P 1N 2P 2N 3P 3N 4P 4N INPUT POWER OUTPUTS RH Non -Power Limited From Power Supply Class 2 Rated Power Limited From Power Supply DC Output to devices Board DC Output to devices Board 1 P-4P Power Outputs, (Factory Installed) I N-4N 14N Common OuPower Outputs, l (Factory Installed) (1 N-4N Common Outputs) tputs) Fig. 3A Fig. 3B Replace fuses with the same type and rating 3.5A, 250V. 1 2 3 4 5 6 7 6 P R*H WM FUSED POWER OUTPUTS 0 . R1R,1 0, LED N ® �H MOM RH-c::: INPUT COMMON POWER OUTPUTS Non- Power Limited From Power Supply DC Output to devices Board 1P-8P Power Outputs, l (Factory Installed) 1N-8N Common Outputs) ICl�l�1�l�l�l/1'I I�l�ICl�l�l�l«�I — \T� I �T• I �T� I `Tr I I \TV I �T� I VT� I �T+ I I I1' I /1' I Class 2 Rated Power Limited From Power Supply DC Output to devices Board (1 P-8P Power Outputs, l (Factory Installed) IN-8N Common Outputs) AL 1024ULXseries - 5 - Wiring: USE 14 AWG or larger for all power connections. Note: Take care to keep power limited circuits separate from non -power limited wiring (115VAC, Battery). Maintenance: Unit should be tested at least once a year for the proper operation as follows: Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level. Battery Test: Under normal load conditions check that the battery is fully charged, check specified voltage both at battery terminal and at the board terminals marked [+ BAT -] to insure there is no break in the battery connection wires. Note: Maximum charging current under discharges is 3.6 amp. Note: Expected battery life is 5 years, however it is recommended changing batteries in 4 years or less if needed. .... . .. . .. 6 - AL 1024ULXseries Battery size calculation worksheet. A. AL 1024ULX series internal current consumption (standby) .05 A B. Load current consumption (standby) A C. Standby time required (hours) H D. Battery capacity required for standby (A+B)*C AH E. AL 1024ULX series internal power consumption (Alarm) .05 A F. Load current consumption (Alarm) A G. Alarm duration (Hours, 15 Min=.2 Hour) (Alarm) .'H "":' H. Battery capacity required for Alarm (E+F)*G • • • • ...... .. . ...... _ _ _ _ .,�H I. Total calculated battery capacity D+H ' • • • •�.H " • • • .. J. Battery capacity required I* 1.8 (safety factor) ...... . . ..... "AH . . . . ...... Note: AL1024ULX series power supply is designed to work with batteries up to 6-'?41?.�rlease,note„ line it... .' must not exceeds 36AH. You have to reduce either standby current consumption or standby tin'ieln.drder to comply with requirement. To determine actual battery size please round line [J] to the nearest larger standard battery size (e.g. 3.5 AH = 4.0 AH). AL 1024Msenes - 7 - Enclosure Dimensions: 15.5"H x 12"W x 4.5"D Top 0° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .•• 0 0 0 0 0 • .•o 0 0 0 0 00n 0000• U• • 0 0 0 0 0 . • • e°0 0 0 0 ° •• (0 0 0 0 0 0 •p 0 0,0 0490•0 • • • 00004 • ••. 06 .. 8, • • • 04 • • • • • • • 1.25" Altronix is not responsible for any typographical errors 1.25" Right o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000000 000000 000000 000000 000000 000000 Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.®� IIAL1024ULX series E24G MEMBER - 8 - AL 1024ULXseries df-52310:A1 • D-050 FCPS-24FS8 8-Amp, 24-Volt Power Supply General The Fire-Lite FCPS-24FS8(CfE) is a compact, cost-effec- tive, 8-amp remote power supplies with battery charger. The FCPS-24FS8C/E) may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may stand-alone. Primary appli- cations include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either two Class B (Style Y) and Class A (Style Z, with ZNAC-4 option module) or four class B only. Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four -wire smoke detec- tors. The FFCPS-24FS8(C/E) also contains a battery charger capable of charging up to 18.0 Amp hour batteries. FCPS- 24FS8C/E) is ULC-listed. NOTE: Unless otherwise specified, the term FCPS-24FS8 used in this document refers to the standard FCPS-24FS8, FCPS- 24FS8C, FCPS-24FS8E Features • UL-Listed Notification Appliance Circuit (NAC) synchroniza- tion using System Sensor, Wheelock, or Gentex "Commander2" appliances. • Operates as a "sync -follower" or as a "sync -generator" (default). See note on page 2. • Contains two fully -isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently "ON" (stand-alone mode). • Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 module) NACs (circuits 1 & 3) • 8-amp full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • 6-amp continuous output in stand-alone mode (UL 1481). • Compatible with coded inputs; signals passed through. • Optional power -supervision relay (EOLR-1). • In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. • Fully regulated and filtered power output - optimal for pow- ering four -wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. • Power -limiting technology meets UL power -limiting require- ments. • Form-C normally -closed trouble relay. • Fully supervised power supply, battery, and NACs. • Selectable earth fault detection. • AC trouble report selectable for immediate 2-hour delay. • Works with virtually any UL 864 fire alarm control which uti- lizes an industry -standard reverse -polarity notification cir- cuit (including unfiltered and unregulated bell power). • Requires input trigger voltage of 9 - 32 VDC. • Self-contained in compact, locking cabinet - 15"H x 14.5"W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). (a Fine•LITeALarms by Honeywell Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp -type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. Specifications Primary (AC) Power: • FCPS-24FS8: 120 VAC, 60 Hz, 3.2A maximum. • FCPS-24FS8/E: 240 VAC, 50 Hz, 1.6A maximum. • Wire Size: minimum #14 AWG (2.Omm2) with 600 V insula- tion. Control Input Circuit: • Trigger Input Voltage: 9 to 32 VDC. • Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: • +24 VDC filtered, regulated. • 3.0 A maximum for any one circuit. • Total continuous current for all outputs (stand-alone mode): — FCPS-24FS8: 6.0 A maximum. • Total short-term current for all outputs (NAC expander mode): — FCPS-24FS8: 8.0 A maximum. df-52310:A1 •08/25/09 — Page 1 of 4 Secondary Power (Battery) Charging Circuit: • Supports lead -acid batteries only. • Float -charge voltage: 27.6 VDC. • Maximum current charge: 250 mA. • Maximum battery capacity: 7.0 AH. Applications Example 1: Expand notification appliance power an additional 8.0 A. Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP noti- fication appliance circuits will activate the FCPS when reverse - polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 6.0 A. Both resettable and non -reset - table power options are available. Resettable outputs are cre- • • • • • • at2d•Vconnectjp Zhe 4,settable output from the FACP to one • or botticof the FOPS frVuts. Ext4le 3: Usk aDaregssable control modules to activate the • • FCPS instead Of•adieating it through the FACP notification •..... aftnd nS Brea% d stanoas:.a acally fromows for mounting he FACP while expanding 9 Y P 9 • �; systemarchitectyVipyarious applications. ...... For example, an addressable control module is used to acti- '. vate the FCPS, ar"ar�addressable monitor module is used to • • segse FQPS tr4bl2 ccliditions. Local auxiliary power output fm" !he• FCPS Qrovidgs power to the addressable control ...... module. .4TFa: Addressable FACPs are capable of locating control and monitor modules at distances of up to 10,000 feet (3,046 meters) . Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24FS8 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24FS8 is configured (via DIP switch settings) as a "sync follower;' the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24FS8 is configured (via DIP switch settings) as a "sync generator," the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchro- nization pulses on the FCPS's NAC outputs. In "sync genera- tor' mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24FS8 complies with the following standards: • NFPA 72 National Fire Alarm Code. • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). • UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S2424 • ULC Listed: S2424 • CSFM Approved: 7315-0075:206 • MEA:219-02E • FM Listed Ordering Information FCPS-24FS8: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15" H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24FS8 is ULC-listed. FCPS-24FS8E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15" H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end -of -line relay for monitoring four -wire smoke detector power. BAT 1270: Battery, 12-volt, 7.0 AH (two required). PS-1270: Battery, 12-volt, 7.0 AH (two required). 90286: Optional module mounting kit, is required to install an addressable module on the power supply main circuit board. Page 2 of 4 — df-52310:A1 •08/25/09 AC ■ Power NOTE: All NAC outputs can be converted to Style Z with Style Y NAC or ZNAC-4 option module. Door Holder Power Style Y NAC Style Y NAC Style Y NAC Output #4 Output #3 Output #2 Output #1 FCPS INPUT/OUTPUT FUNCTIONS are programmable by SW1 DIP switch settings Battery Charger Simplified Block Diagram FCPS Trouble Contact Output 24 VDC Specific MW* App4oetion • • .. . Povwer• .. . •••••• •••••• NAfitontrol ••••.• Input•#2 • �•�•�� .... f Fi4CP . ..... •••••; NQE Ccritrol ••�••• InpM #? •••••• ;• ;•; . . (from IFACP) . . •• ...... ...... Sjn;'Ihput .... ' df-52310:Al • 08/25/09 — Page 3 of 4 N • .•. 'ON y y K A W p O U $ m 'c c U o v m o `LLro ``oa E E E p-Y; 0 0 O N O O Z Z O mLL` 'On- �U SUE O O N M CO � •••r O > j • • • • �a NN ••• • • J � U L) + ••••• •x• • • • aaZZ CO •••••• •• •• O"ko • • •••••• • o c pe• - • No -VZ• is � �c» �I I ru`, . • • •••••aIf; o ZZ• Z'a • • O •••••• -�.•C30 • • • • •• �c o'm 0 •• • • 3�y Eaa ci arro mN iafh I" I I L U 3 C N N V a L d O O & 7 C E o a a E m a a m Z 2 E c c E E E a a 'k 3pp a U N `O O` U S 2 E C G Q y U U y Q Q U U O O U U rn rn ti Z + I + i + 1 + I + Z�Z (� IeO M m ^O �m c 30 00a O o c `U O � O o a t(> Q m� E E_U 3 @U oa (0a`o EE£ J N O y C 0 f ` F ® z �' ~ o o 000 o o ❑aa O e Board Layout System Sensor® and FireLite® Alarms are registered trademarks of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 'SO 9oo1 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EVINEUUNG A MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4 — df-52310:A1 •08/25/09 AES_7744F 7788F.gxd 8/24/2009 11:04 AM Pagel 7744F/7788F.,,il ES IntelllNet CORPORATION For Alarm Monitoring RF Subscriber Unit UL Fire, AA Burglary and NFPA-72 Compliant UL Listed UL Listed Central Station Remote Station 864 Ed. 9, 827, 1610, 365, 681 CSFM NFPA RF Section 8.6.3.5 • Advanced Wireless Alarm Monitoring The 7744F/7788F smart subscriber unit links an alarm panel to an alarm monitoring central station. This 2-way transceiver and repeater in one is housed in a full size locking steel cabinet for superior performance. The 7744F/7788F supports a wide range of inputs such as NO/NC/EOL and direct voltage. It automatically senses wire and antenna cuts, and monitors battery and AC power status. Advanced status reporting, self -diagnostics and a built-in power supply make the 7744F/7788F the first choice for all wireless alarm communication needs. Full Data for Fire and Burglary Use with the optional Firetap for full fire data or the IntelliTap for full fire and burglary data. 7744F — 4 reversing polarity inputs plus 4 programmable EOL inputs 7788F — Programmable EOL inputs with 8 zones FireTap 7770 IntelliTap 7067 NEMA 4 Enclosure High Gain Antenna Additional Back Up Battery Available in Burglary Beige or Fire Red • Options for FulI JUAWfor Fire an.0*AVrg1arx + • • • • Availablejw 7744F & 7788F. Zone ebt figurabpAg• • • • • • • • Y •"1 • • • ••.• • Built'VA'nrer Supply and ••.•. Battww.Wwrger • . • • • • Locai Annwnciation : • • • •: Options on Boatd;..• c �L us � �s�n � n iui�en LISTED Wireless mesh networking is an innovative technology adopted by many industries with applications that need to communicate data over a large geographic area with a high level of reliability at a low total cost of ownership. The advanced design and 2-way communications capability provides easy installation, expansion, and management when compared to alternative communication methods, both wired and wireless. AES-7744F 7788F.gxd 8/24/2009 11:04 AM Page 2 7744F/7788F RF Subscriber Unit Technical Specifications Radio Standard CSAA frequency ranges: 450-470 MHz and 130-174 MHz, VHF andi,WNF. Others available StatRffitd Outpyrl�owgr 2 yAp trgquires•FC(T license) Pofiel Input 16.5 VAC, 40VA bVi9tt-8 C!pl%V jtPnsfor%&"4tyired Voltage ' •" 1ZVpC•ttpminal; • •; • • CuPre nf • • • • 1754A standby; WQm• iansmit A14"Si nal Inp. is • 4 individually pmgm �rnable Zones: 196A C40L, trouble restore • RS232 • Reversing voltage (7744F only) 12 or 24 VDC Operating Temperature Range 0° to 50°C, 32' to 122°F Storage Temperature Range -10° to 60oC, 14° to 140°F Relative Humidity Range 0-85% RHC non -condensing Back up Battery 12V, 7.5 AHr Low Battery Reporting 22.5-minute test cycle AC Status Reports to central station after approximately 60 minutes without AC power, reports power restored after approximately 60 minutes of restored power. programmable from 60 to 180 minutes Antenna Cut (local reporting) Form 'C' Contact 1 AMP Size 13.25"H x 8.5"W x 4.3"D 34cm x 21.5cm x 11 cm Weight 6.4 Ibs, 2.9 Kilograms (excluding battery) Colors Available in standard Burglary Beige or Fire Red Please specify when ordering Available Options • 7788F RF subscriber unit with 8 EOL inputs • 7744F RF subscriber unit with 4 EOL inputs and 4 reverse polarity inputs • 7770 - FireTap • 7067 - IntelliTap • NEMA 4 Enclosure Please specify when ordering AES-IntelliNet" is the industry leader in delivering high quality wireless mesh networks to the fire and security industry in commercial. corporate. government, and educational applications with its broad line of products and advanced network management tools. Users of AES-IntelliNet networks have gained significant revenue, communications.. and cost advantages while meeting the high standards of reliability required for the fire and security industry. AES-IntelliNet alarm monitoring systems are deployed at hundreds of thousands of locations in over 130 countries. -%ram ,► =-::11AES IntelfiNet CORPORATION For Alarm Monitoring For more information Call 800-AES-NETS (800-237-6387) AES Corporation 285 Newbury Street Peabody, MA 01960 USA Tel. +1 978-535-7310 Fax +1 978-535-7313 Email info@aes-intellinet.com Web www.aes-intellinet.com Available configurations • 7788F, 8 EOL inputs • 7744F, 4 EOL inputs w/4 reverse polarity inputs Copyright 2009 AES Corporation AES-intelliNet is a registered trademark of AES Corporation 7744F/7788F/08/09 DN-60977:A FSP-951 Series Intelligent Plug -In Photoelectric Smoke Detectors General The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the con- trol panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T. The FSP-951 R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan® and CLIP applications as designated. Features • New modern profile for improved aesthetics. • Designed to meet UL268 7th Edition. • Stable communication technique with noise immunity. • Low standby current. • Two -wire SLC connection. • Compatible with FlashScan® and CLIP protocol systems. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Optional remote, single -gang LED accessory. • Dual LED design provides 360° viewing angle. • Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan sys- tems only). • Remote test feature from the panel. • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1(FlashScan systems only). • Built-in functional test switch activated by external magnet. • Built-in tamper -resistant feature. • Sealed against back pressure. • Expanded color options. • SEMS screws for wiring of the separate base. • Optional relay, isolator, and sounder bases. Specifications Sensitivity: • UL Applications: 0.5% to 4.0% per foot obscuration. • ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter. — B300-6: 6.1" (15.6 cm) diameter. — B501: 4" (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4oz (96.4g) Operating Temperature range: • FSP-951, 0°C to 50oC (32°F to 122°F). • FSP-951 T, 0°C to 38°C (32°F to 100°F). NOTIFIER` by Honeywell • • • •••••• •••• • ••••• • • • • • •••••• • 00 • • • • • • * ;•.••; FSP-951 is 630ra Base •• • • •• • • • • • FSP-951R installed in a DNR/DNRW, -20oC to 70oC (-4°F to 158°F). UL/ULC Listed Velocity Range: 0-4000 fUmin. (1219.2 m/min.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed -temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 200pA @ 24VDC (one communica- tion every five seconds with LED enabled). LED Current (max.): 4.5mA @ 24 VDC ("ON"). Installation FSP-951 series plug-in detectors use a separate base to simplify installation, service, and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60981. NOTE: 1) Because of inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class `B') wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. DN-60977:A • 4/17/18 — Page 1 of 3 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document. In some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listed: S911 • FM Approved • CSFM:7272-0028:0503 Product Line Information NOTE: • Detectors must be mounted to one of the Intelligent Bases listed below. • `A" suffix indicates ULC Listed model. • `1V" s0ix indicates FlashScanO and CLIP device. • • • FSP-951: JVNtg, low-profild VAligent photoelectric sensor, FlashS- • • can only.• • - •••••• • •• ease** . F$P-951A: *Same as FSfjr:!61.6ut with ULC listing. sees.• • FSP-951;ly- v& low-RrGAILK%elligent photoelectric sensor. MP-95A-IV: Same as FSP 9 1MP-IV but with ULC listing. sees• � •••.. • a • FSP-951 j; %Nt9, sam; "'Fad-951 but includes a built-in 135°F •• (57°C) fixed temperatu%jV4rpgl device. FlashScan only. .: e• FCP-951TA: Same as F%P 951aef but with ULC listing. sees•• ... f�P-951T-IV: Ivory, sarr 4s FIP-951T but includes a built-in 135°F • (N-C) fide %m;eraturd- thefrl%l device. FSP-951TA-10?Same as FSP-951T-IV but with ULC listing. FSP-951R: White, low -profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FlashScan only. B224BI-WH: White, isolator detector base. B224BI-IV: Ivory isolator detector base. B224BIA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B20OS-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. FSP-951RA: Same as FSP-951 R but with ULC listing. For use with B200SR-IV: Ivory, Intelligent sounder base capable of producing DNRA. sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. FSP-951R-IV: Ivory, low -profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FSP-951 RA -IV: Same as FSP-951 R-IV but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 13300-6: White, 6" base, standard flanged low -profile mounting base. B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base. 13300A-6: Same as B300-6, ULC listed. B30OA-6-IV: Ivory, 6" standard flanged low -profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as 6200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base. B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B210LP(A) base. base. UL/ULC listed. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a B501-BL: Black, 4" standard European flangeless mounting base. U.S. single -gang electrical box. For use with B501(A) and B300(A)- UUULC listed. 6. B501-IV: Ivory color, 4" standard European flangeless mounting M02-04-00: Test magnet. base. UL/ULC listed. M02-09-00: Test magnet with telescoping handle. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. Page 2 of 3 — DN-60977:A • 4/17/18 ...... .. . ...... .... ...... 00060 • .... . ••••• • • ••••• .. •• •• •• •.•.•• . • • • • . • . • • .•..•• • 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I O 9oo We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENGINEERING 8 MANIFALTINK QUALITY SYSTEMS For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com Page 3 of 3 — DN-60977:A • 4/17/18 DN-60975:A FST-951 Series Intelligent Thermal (Heat) Detectors General The NOTIFIER FST-951 Series intelligent thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the FST-951 Series ideal for both system operation and build- ing design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 135°F/ 57°C fixed -temperature, rate -of -rise and a 180°F/88'C fixed high - temperature detectors. These thermal detectors provide effective, intelligent property protection in a variety of applications. Detectors are available for both FlashScan® and CLIP applications as desig- nated. Features • Sleek and stylish contemporary design. • Advanced thermal technology for fast response. • Fixed temperature model (FST-951) factory preset to 135°F (57°C). • Rate -of -rise model (FST-951 R), 15°F (8.3°C) per minute. • High temperature model (FST-951H) factory preset to 190°F (88°C). • Addressable by device. • Compatible with FlashScan® and CLIP protocol systems. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Two -wire SLC connection. • Visible LEDs "blink" every time the unit is addressed. • 360°-field viewing angle of the visual alarm indicators (two bi- color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. • Integral communications and built-in device -type identification. • Remote test feature from the panel. • Built-in functional test switch activated by external magnet. • Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). • Low standby current. • Built-in tamper -resistant feature. • Designed for direct -surface or electrical -box mounting. • Sealed against back pressure. • Plugs into separate base for ease of installation and mainte- nance. • SEMS screws for wiring of the separate base. • Optional remote, single -gang LED accessory. • Optional sounder, relay, and isolator bases. Specifications Size: 2.0" (5.3 cm) high; base determines diameter. — B300-6: 6.1" (15.6 cm) diameter. — B501: 4" (10.2 cm) diameter. For a complete list of detector bases, see DN-60981 Shipping weight: 3.4oz (96.4g) Operating temperature range: • FST-951, FST-951 R Series: —20°C to 38°C (-4°F to 100°F); • FST-951 H Series: —20°C to 66°C (-4°F to 150'F). �J NOT FI E Rp by Honeywell ...... .. . ...... ... ...... FST-951 R in 6; 'Base • • • • • • • ...00 Detector spacing: UL approved for 50 ft. 15.24 m) cede; to cent2f' • • FM approved for 25 x 25 ft. (7.62 )V. spacing. ' • Relative humidity: 10%— 93% nor -condensing. •..... Thermal ratings: Fixed-temperaturQ sit point 57; (Ia'F), ratebof• •.: rise detection 8.3°C (15°F) per minute, high temperature, heat 8A°C ' (190-F). ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 200uA @ 24 VDC (one communica- tion every 5 seconds with LED enabled). LED current (max.): 4.5mA @ 24 VDC ("ON"). Applications Use thermal detectors for protection of property. For further informa- tion, refer to 156-6522, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. Installation The FST-951 Series plug-in intelligent thermal detectors use a sepa- rate base to simplify installation, service, and maintenance. Installa- tion instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE. 1) Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class `B) wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. DN-60975:A • 4/23/18 — Page 1 of 3 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document.ln some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UUULC Listing: S2101 FM Approved CS FM: 7270-0028:0502 Product Line Information NOTE: 'A" suffix indicates ULC Listed model. NOTE: "-IV" suffix indicates FlashScanO and CLIP device. FST-951: White, low -profile intelligent 1350F fixed thermal sensor, FlashScan only. FST-951 A: Same as FST-951 but with ULC listing. FST-951-IV: Ivory, low -profile intelligent 135°F fixed thermal sensor, FlashScan and CLIP. •••• • • • • • FST-954A-IY:Same as FST-9.51-IV but with ULC listing. • • FST-9516: \Vhte, low;rofila intelligent rate -of -rise thermal sensor, FlashSC&POW ...... • ;ST-951 RA: Same as FST•95I R but with ULC listing. T-951 R—! %:� gory, low?-l1rMQ intelligent rate -of -rise fixed thermal ....sensor, rlashSaan and CLIP' • • • •146T-951VA, IV Same Vrlf-kl R-IV but with ULC listing. • • • "'FST-951N White, low-pr`f�lg jrltelligent 190°F fixed thermal sensor, • FlashScan dnly. . • • "•• nT-951!*A�* Cab as FS•T-951�i but with ULC listing. • • • f6T-951 H;ly: h4pry, low -profile intelligent 190°F thermal sensor, • FrashScan arfd CLIP. .... FST-951 HA -IV: Same as FST-951 H-IV but with ULC listing. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 B300-6: White, 6" base, standard flanged low -profile mounting base. B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base. B300A-6: Same as B300-6, ULC listed. B30OA-6-IV: Ivory, 6" standard flanged low -profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed. B501-BL: Black, 4" standard European flangeless mounting base. UUULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. 622461-WH: White, isolator detector base. B224BI-IV: Ivory isolator detector base. B224BIA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B20OS-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH with, ULC listing. 6200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base. TR300-IV: Ivory, replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B3006(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. DN-60975:A • 4/23/18 — Page 2 of 3 ...... .. . • ...... . ... •••••• • •.•••. • .... . ..... •••••. • • 00000 .. .. .. .. ...... .. ...... so .. • • Notifier® and Flash Scan® are registered trademarks of Honeywell International Inc. Notifier® and Bayblend@ is a registered trademark of Bayer Corp. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 'SO 9oo1 cannot try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. 9YU A L IIT 8 SYSTEMS S T E M S For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. QUALITY SYSTEMS www.notifier.com Page 3 of 3 — DN-60975:A • 4/23/18 dn-6935:c • H-202 FSP-851, FSP-851 T, & FSP-851 R Intelligent Plug -In Photoelectric General Notifier 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conven- tional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously moni- tored and reported to the panel. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector location for selective main- tenance when chamber contamination reaches an unaccept- able level. The FSP-851 photoelectric detector's unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed -temperature thermal sens- ing on the FSP-851 T. The FSP-851 R is a remote test capable detector for use with DNR(W) duct detector housings. FSP-851 series detectors are compatible with all ONYX series Notifier intelligent Fire Alarm Control Panels (FACP). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of ear- lier designs. Features • Sleek, low -profile design. • Addressable -analog communication. • Stable communication technique with noise immunity. • Low standby current. • Two -wire SLC connection. • FlashScan (NFS-320, NFS-640, NFS2-640, NFS-3030, NFS2-3030) and classic CLIP systems (AFP-100, AFP- 200, AFP-300, AFP-400, NFS-640, AM2020/AFP1010, NFS-3030) compatible. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Optional remote, single -gang LED accessory. • Dual LED design provides 360' viewing angle. • Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). • Remote test feature from the panel. • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1(FlashScan systems only). • Built-in functional test switch activated by external magnet. • Built-in tamper -resistant feature. • Sealed against back pressure. • Constructed of off-white Bayblend®, designed to commer- cial standards, and offers an attractive appearance. • 94-5V plastic flammability rating. • SEMS screws for wiring of the separate base. • Optional relay, isolator, and sounder bases. �J NOTIFIERF' by Honeywell FSP-851 with B71OLP base .s• FSP-851T with 12716LP base • Specifications ' • • • Size: 2.1" (5.3cm) high x 4.1" (10.4cm) diameter installed in B501 base, 6.1" (15.5cm) diameter installed in B710LPbase. Shipping Weight: 5.2oz. (147g). Operating Temperature: FSP-851, 0°C to 49°C (32°F to 120°F); FSP-851T, 0°C to 38°C (32°F to 100°F). Low temper- ature signal for FSP-851T at 45°F +/- 10°F (7.22°C +/- 5.54°C). FSP-851 R installed in a DNR(W), -20oC to 70oC (-4°F to 158°F). ULIULC Listed Velocity Range: 0-4000 f /min. (1219.2 m/ min.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed -temperature setpoint 135°F (57°C) DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at system sensor. com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300pA @ 24VDC (one com- munication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24VDC ('ON'). BASES AVAILABLE NOTE: A" suffix indicates ULC Listed model. dn-6935:c • 3/12/10 — Page 1 of 2 B71OLP(A): 6.1" (15.5cm) diameter B501(A): 4.1" (10.4cm) diameter. B200SR(A): Intelligent sounder base, configurable for temp-3 or steady sound. B224RB(A) Relay Base: Screw Terminals, up to 14AWG (2.Omm2); Relay Type, Form-C; Rating, 2.OA @ 30VDC resis- tive, 0.3A @ 11OVDC inductive, 1.OA @ 30VDC inductive; Dimensions, 6.2" (15.748cm) x 1.2" (3.048cm) x 1.21, (3.048cm). B224BI(A) Isolator Base: Dimensions, 6.2" (15.748cm) x 1.2" (3.048cm) x 1.2" (3.048cm); Maximum, 25 devices between isolator bases. Installation FSP-851 plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors with- out using a ladder. Mbtfif base on an electrical backbox which is at least 1.5" • • • • • (a..Shan) deep.. %ital$e mounting base boxes include: • S • 4.t' i;10.16cm) square box. • • • • •' • ... • • `3V (8.89cm� or 4.(10.16cm) octagonal box. • ' ••• •• • bpi (�e;Ccept relay or isolator base). ' .�ingle-gang • •With 4 200SR Pgf&% Lse an appropriate junction box. •••.. • With B224RQ p6182241]11 base, use a 3.5" (8.89cm) octago- nal box, or a %0,',' tt0.16cm) octagonal or square box. •1) ' ; • • ` ` NOTE: BecaVV a "erent supervision provided by the SLC • loop end-of-lineo resistors are not required. Wiring 7-taps" or • • . • • • bs�irjF % are permitted for style 4 (Class "B') wiring. 2) When • . using relay or sou rfdgr bases, consult data sheet DN-2243 (ISO-X) • • • • • • • • for di vice4limitatiIns between isolator modules and isolator bases. • • . Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S1115 • ULC Listed: S1115 (FSP-851A, FSP-851TA) • MEA Listed: 225-02-E • FM Approved • CSFM:7272-0028:206 • Maryland State Fire Marshal: Permit # 2122 • BSMI: C1313066760036 • CCCF: Certif. # 2004081801000017 (FSP-851T) Certif. # 2004081801000016 (FSP-851) • Lloyd's Register: 03/60011 Product Line Information NOTE: 'A or "CDN" suffix indicates ULC listed model. FSP-851:Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A:Same as FSP-851 but with ULC listing. FSP-851T:Same as FSP-851 but includes a built-in 135°F (57°C) fixed -temperature thermal device. FSP-851TA:Same as FSP-851T but with ULC listing. FSP-851 R: Low -profile intelligent photoelectric sensor, remote test capable. For use with DNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. BASES B71 OLP: Standard U.S. low -profile base. B71OLPBP:Standard U.S. low -profile base, pkg. of 10. B71 OLPA:Standard U.S. low -profile base, ULC listing. B501BP:Standard European flangeless base, pkg. of 10. B501A:Standard European flangeless base, ULC listing. B200SR(A): Intelligent sounder base, configurable for temp-3 or steady sound. B224RB(A):Intelligent relay base. B224B1(A):Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES F110:Retrofit replacement flange for older style bases. Con- verts older high profile base for use with FlashScan detectors. RA100Z(A):Remote LED annunciator. 3-32VDC. Fits U.S. single -gang electrical box. Supported by B71 OLP(A) and B501(A) bases only. SMK400E:Surface mounting kit provides for entry of surface wiring conduit. For use with B501(A) base only. RM K400: Recessed mounting kit. For use with B501(A) base only. SMB600:Surface mounting kit for use with B710LP(A). BCK-20OB:Black detector covers, box of 10. For use with FSP-851 only. WCK-20OB: White detector covers, box of 10. For use with FSP-851 only. M02-04-00:Test magnet. M02-09-00:Test magnet with telescope stick. XR2B:Detector removal tool. Allows installation and/or removal of FlashScan Series detector heads from base in high ceiling installations. T55-127-01 0: Detector removal tool without pole. XP-4:Extension pole for XR215. Comes in three 5-ft. sections. Notifier® and FlashScanOD are registered trademarks of Honeywell Interna- tional Inc. Bayblend® is a registered trademark of Bayer Corporation. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MINEBINR R MMUFACIURINR All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - dn-6935:c • 3/12/10 dn-6936:a1 • H-211 FST-851 Series Intelligent Thermal (Heat) Detectors with FlashScan@ General Notifier FST-851 Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations. FST-851 Series thermal detectors use an innovative thermistor sensing circuit to produce 135°F/ 57°C fixed -temperature (FST-851) and rate -of -rise thermal detection (FST-851 R) in a low -profile package. FST-851 H pro- vides fixed high -temperature detection at 190°F/88°C. These thermal detectors provide effective, intelligent property protec- tion in a variety of applications. FST-851 Series detectors are compatible with all Notifier intelligent Fire Alarm Control Pan- els, except FireWarden series panels. . FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features • Sleek, low -profile, stylish design. • State-of-the-art thermistor technology for fast response. • Rate -of -rise model (FST-851 R), 15°F (8.3°C) per minute. • Factory preset at 135°F (57°C); high -temperature model at 190°F (88°C). • Addressable by device. • Compatible with FlashScan® and CLIP protocol systems. • Direct dial entry of address 01-159 for FlashScan® loops, 01-99 CLIP mode loops. • Two -wire SLC connection. • Visible LEDs "blink" every time the unit is addressed. • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. • Integral communications and built-in device -type identifica- tion. • Remote test feature from the panel. • Built-in functional test switch activated by external magnet. • Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). • Low standby current. • Backward -compatible. • Built-in tamper -resistant feature. • Designed for direct -surface or electrical -box mounting. • Sealed against back pressure. • Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. • SEMS screws for wiring of the separate base. • Constructed of off-white Bayblend®, designed to commer- cial standards, and offers an attractive appearance. (�� NOTI FI E R' by Honeywell FST-851 Series in B71OLP base • 94-5V plastic flammability rating. 0000 • Remote LED output connectiorito optional RA#OQZ remote LED annunciator. • • • """ • Optional sounder, relay, and isQl:tptposes. • •+�• '. 60 • Optional recessed (RMK400) ofi a;arWe (SMK402E) base s • mounting kits. � � • • � � . • • • • . • • •••••• • • Specifications "'•' Size: 2.1" (5.3 cm) high x 4.1" (1Artcr Tdiametgf4iTs4jIed in B501 base, 6.1" (15.5 cm) diameWi4c Tglled in B710OP base. • Shipping weight: 4.8 oz. (137 g�. • . • Operating temperature range: tST--,8% Serie3, FST-851 R: —• • 20°C to 38°C (-4°F to 100°F); FSI•Zl51 Ft—20°Gto 6&C (-4°F,' •' • to 150°F). ' ' ' Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% — 93% noncondensing. Thermal ratings: fixed -temperature setpoint 135°F (57°C), rate -of -rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (88°C). Altitude rating: 10,000 feet. ELECTRICAL SPECIFICATIONS: Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 300 pA @ 24 VDC (one com- munication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @ 24 VDC ("ON"). BASES AVAILABLE: B710LP: 6.1" (15.5 cm) diameter. B501: 4.1" (10.4 cm) diameter. B501 BH-2 or B501 BHT-2: Sounder base assembly. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). B224BI Isolator Base: Dimensions: 6.2' (15.748 cm) x 1.2" (15.748 cm). Maximum: 25 devices between isolator bases. See Note 2 under Installation. Applications Use thermal detectors for protection of property. For further information, go to systemsensor.com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- dn-6936:a1 •06/8/09 — Page 1 of 2 vides detailed information on detector spacing, placement, B501: Standard European flangeless base. zoning, wiring, and special applications. B501(A): Standard European flangeless base, ULC Listing. Installation The FST Series plug-in intelligent thermal detector uses a sep- arate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. Suitable boxes include: • 4.0" (10.16 cm) square box. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. • Single -gang box (except relay or isolator base). • With B501 BH-2 or B501 BHT-2 base, use a 4.0" (10.16 cm) square box. • With B224RB or B224BI base, use a 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or a 4.0" (10.16 cm) square box. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring 7-taps" or bill are permitted for Style 4 (Class 'B') wiring. 2) When « 0 L`iogl selay or sounder bases, consult data sheet DN-2243 (ISO-X) • • • • f • fob dgvjce limitaCons bctween isolator modules and isolator bases. "• «• • f • f • 000000 A•agency LIACngs and Approvals • • • «; These listings antivp%ovals apply to the modules specified in titMMb ment. rhol cases, certain modules or applications • • • • • « may nT be list"IaAQartain approval agencies, or listing may • • • •' tae iN process. CVV81j factory for latest listing status. • 11L Listed: S76z... • JJLC 6isted:%6978MEA Listed: 383-02-E « •• W A'proved • . : • • «• « • • 406FNk 7270;0281.196 ••86!191: C1313066760025 • CCCF: Certif. # 2004081801000018 • U.S. Coast Guard: 161.002/23/3 (AFP-200); 161.002/27/3 (AFP1010/AM2020); 161.002/42/1 (NFS-640) • Lloyd's Register: 03/60011 Product Line Information "A" suffix indicates ULC Listed model. FST-851: Intelligent thermal detector. Must be mounted to one of the bases listed below. FST 851 A: Same as FST-851 but with ULC Listing. FST 851 R: Intelligent thermal detector with rate -of -rise feature. FST 851 RA: Same as FST-851 R but with ULC Listing. FST851H: Intelligent high -temperature thermal detector. FST 851 HA: Same as FST-851 H but with ULC Listing. BASES: B71OLP: Standard U.S. low -profile base B71OLPBP: Standard U.S. low -profile base, pkg. of 10. B71OLP: Standard U.S. low -profile base. BH501 BH-2: Sounder base, includes B501 base above. BH501 BHT-2: Same as B501 BH-2, but includes temporal sounder. BH501 BHA: Sounder base, includes B501 base above BH501 BHTA: Same as BH501 BHA, but includes temporal sounder. B224BI(A): Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: F110: Retrofit replacement flange for older style high profile bases. Converts bases for use with FlashScan® detectors. RA400Z(A): Remote LED annunciator. 3 — 32 VDC. Fits U.S. single -gang electrical box. Supported by B710LPBP(A) and B501 (A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501 (A) base only. RMK400: Recessed mounting kit. For use with B501 (A) base only. SMB600: Surface mounting kit for use with B710LPBP(A). BCK-20OB: Black detector covers, box of 10. M02-04-00: Test magnet. M02-09-00: Test magnet with telescope stick. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR213. Comes in three 5-ft. sections. B710LP(A): Standard U.S. low -profile base. Notifier® and Flashscan® are a registered trademark of Honeywell International Inc. Bayblend® is a registered trademark of Bayer Corp. B501 BP: Standard European flangeless base, pkg. of 10. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this docu- ment is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MINESINi R MANUFALTURINR All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — dn-6936:a1 •06/8/09 INSTALLATION AND MAINTENANCE INSTRUCTIONS B200SR Intelligent Sounder Base SYSTEM w N SEMSOR` 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systemsensor.com Specifications Base Diameter: 6.875" (17.46 cm) Base Height (less sensor): 2.0" (5.08 cm) Weight: 0.50 lb. (227 gm) Operating Temperature Range: 32° to 120°F (0° to 49°C) Operating Humidity Range: 10% to 93% relative humidity (non -condensing) External Supply Electrical Ratings External Supply Voltage: 16 to 33 VDC (VFWR) Standby Current: 500 pA maximum Alarm Current: 35 mA maximum SLC Electrical Ratings SLC Operating Voltage: 15 to 32 VDC SLC Standby Current: 300 pA maximum Sound Output Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) BEFORE INSTALLING Please read the System Sensor Smoke Detector Application Guide, which pro- vides detailed information on sensor spacing, placement, zoning, wiring, and special applications. Copies of this manual are available from System Sensor. NFPA 72 and NEMA guidelines should be observed. NOTICE: This manual should be left with the owner/user of this equipment. IMPORTANT: The detector used with this base must be tested and maintained regularly following NFPA 72 requirements. The detector should be cleaned at least once a year. GENERAL DESCRIPTION The B200SR sounder base is used with System Sensor 200-Series sensor heads or equivalent. For a list of compatible sensors, refer to the System Sensor web - site at www.systemsensor.com. Refer to the appropriate manual for more infor- mation on sensors. The B200SR sounder base was designed specifically to meet the needs of dwelling unit applications. It offers maximum flexibility in configuration and operation to meet or exceed the requirements of UL268 and WA64. The sounder base is capable of producing either the distinctive three -pulse temporal pattern (ANSI Temporal 3) fire alarm signal now required by NFPA 72 for commercial and residential applications or a continuous tone by simply removing the included jumper from the device. Additionally, the B200SR is designed to be compatible with existing installations of B501-Series sounder bases. The sounder base is intended for use with intelligent systems. The sounder base requires an external 24 VDC power supply. The connections for the external power supply and the communication loop are isolated to prevent electrical interaction between them. Refer to the panel manual for maximum allowable number of units per loop. NOTE: For NFPA72 Installations, the Temporal 3 tone should be used for public mode evacuation. NOTE: When not used as a supplementary evacuation system, the external 24 VDC supply shall be treated as a component of the main power supply system and shall fall under the requirements of the main power supply system per NFPA 72. • • •••• •••••• WIRING GUIDELINES • • • • All wiring must be installed in compliance with the Nstionel Electrical Code • and the local codes having jurisdiction and.•tnust not be of such length or wtie • size which would cause the base to of elAg 8i tside of its ptiblished spe ig%a& . ; tions. The conductors used to connegt's? MRe�sensor;tp cgltgpl panel% and • accessory devices should be color coded "reduce t* likelihood of wisft % errors. Improper connections can preveeb a system from.responding pr pealp • in the event of a fire. 000000 • • 400 . • • • • • • • • Wire sizes up to 12 AWG (2.5 mmz) r1JYt tr:ed with the base. The soundei base will be shipped with the screwoerminals set fot•14 AWG wiringpli 4h • • AWG wire is to be used, back out the,screwt, to allow Veowire to fit beneath • the clamping plates. For best system ISejfgMn4ce, the power j + and -), ifeS' ; and the communication circuit wires should be twistetl�arg Shielded cable installed in a separate grounded conduit to protect the communication loop from electrical interference. Make wire connections by stripping about 3/8" of insulation from the end of the wire. Then, slide the bare end of the wire under the appropriate clamping plate (See Figure 1), and tighten the clamping plate screw. Do NOT loop the wire under the clamping plate (See Figure 2) The wiring diagram for a typical 2-wire intelligent system is shown in Figure 4. ACAUTION For system monitoring - for terminals 4 and 5, do not use looped wire under termi- nals. Break wire run as shown in Figure 2 to provide monitoring of connections. SS-450-001 1 156-3392-003R FIGURE 1: FIGURE 2: THIS ..•• •.•..• . • .••••. ..... . .... ..... . ...... ...... ... .... • : • B200SR THIN s • • No! Function • • • • 1. •Not UsgQ • • � • • • 2. Positive f (!omm. Line In and Out 3. Negative (-) Comm. Line In and Out 4. External Supply Positive (+ ) 5. External Supply Negative (-) 6. Sounder Base Interconnect C0471-01 NOT THIS 0 fl C0473-00 MOUNTING Mount the B200SR mounting plate directly to an electrical box. The plate will mount directly to 4" square, 4" octagon, single gang and double gang junc- tion boxes. 1. Connect field wiring to terminals, as shown in Figure 1 and 2. 2. Attach the mounting plate to the junction box as shown in Figure 3. 3. To mount the sounder base, hook the tab on the sounder base to the groove on the mounting plate. 4. Then, swing the sounder base into position to engage the pins on the product with the terminals on the mounting plate. 5. Secure the sounder base by tightening the mounting screws. 6. Install a compatible smoke sensor as described in the installation manual for the sensor. TESTING AND MAINTENANCE Sensors and bases must be tested after installation and as an integral part of a periodic maintenance program. Test the B200SR as follows: NOTE: Before testing, notify the proper authorities that the smoke sensor system is undergoing maintenance and, therefore, will be temporarily out of service. Disable the system undergoing maintenance to prevent unwanted alarms. 1. If configured as in Figure 4 and 5, reverse the polarity of the external 24VDC supply. If configured as in Figure 5, turn on the Intelligent Relay Module. All B200SR bases on the loop should sound. 2. Latch the sensor LED on from the control panel. That individual sensor's B200SR should sound. When performing maintenance on connected smoke sensors, carefully note the location and address of each removed sensor. FIGURE 3: MOUNTING Location of jumper — remove to enable continuous tone C0891-03 SS-450-001 2 156-3392-003R FIGURE 4: WIRING DIAGRAM DETECTOR ACTIVATES SOUNDER BASE(S) - (COMPLIES WITH UL268) UL has approved grouping for up to six B200SR sounder bases. When wired as a group, any detector in the group that has been activated by the panel will cause other B200SR units in the group to sound. This type of "local" grouping is accomplished by wiring the grouped devices together using terminal 6, Sounder Base Interconnect, as shown in the diagram. This interconnect can also be used to attach B200SR devices to System Sensor B501-Series sounder bases. Some Fire Alarm Control Panels (FACP) support the grouping of sounder bases via software in lieu of the Sounder Base Interconnect. NOTE: A local grouping of horns via the sounder base interconnect is not supervised, therefore the groups can only be used as a supplementary evacuation system. It is not acceptable to group horns via the sounder base interconnect for primary alarm signaling. Sounder bases which are grouped via software are not subject to this limitation and may be used as part of the primary alarm signaling. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ CLASS A OPTIONAL WIRING INTELLIGENT MONITOR MODULE _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - ()SLC I-) SLC (-) SLC (+) SLC OPTIONAL SOUNDER INTERCONNECT' C UL D 78 Ea \ RESISTOR j / 4. END OF LINE RELAY 61 R R ; • (EOLR-I OR EQUIVALENT) fIRST SKDND LAST • • • • • • ! ! • • • • (,)POWER SOUNDER SOUNDER SWROER •I • • • BASE BASE / BASE I• • • • • • • •1• • • • • • • • • • • • • • (-)POWER 1 • I va ______________•I1••••• • • • __________________________________________� CLASS A OPTIONAL WIRING / _ • • • • • ! • • __________________________________________ _______________ ,)}_!! u • • GROUPING OF UP TO 6 MODEL B200SR SOUNDER BASES • • • • • • • • • • C,0)70 011 • •• •• •• •• •••••• • • • • • •••••• FIGURE 5: WIRING DIAGRAM • • • • • DETECTOR ACTIVATES SOUNDER BASE(S); ` ` ' "`• • ` INTELLIGENT RELAY MODULE ACTIVATES ALL SOUNDER BASES - (COMPLIES WITH UL 268 AND UL 464) ADDITIONAL AUDIBLE WSIBLE DEVICES ARE SYNCHRONIZED TO THE SOUNDER BASE OUTPUT *of* UL has approved grouping for up to six B200SR sounder bases. When wired as a group, any detector in the group that has been activated by the panel will cause other B200SR units in the group to sound. This type of "local" grouping is accomplished by wiring the grouped devices together using terminal 6, Sounder Base Interconnect, as shown in the diagram. Some Fire Alarm Control Panels support the grouping of sounder bases via software in lieu of the Sounder Base Interconnect. NOTE: A local grouping of horns via the sounder base interconnect is not supervised, therefore the groups can only be used as a supplementary evacuation system. It is not acceptable to group horns via the sounder base interconnect for primary alarm signaling. Sounder bases which are grouped via software are not subject to this limitation and may be used as part of the primary alarm signaling. INTELLIGENT MONITOR MODULE (+) SLC (-) SLC (-) SLC I.) SLC INTELLIGENT OPTIONAL SOUNDER INTERCONNECT' T <w RELAY MODULEt o /r w COMM 2 (-) SLC / UL LISTED 10 NC 2 1+) SLC / \ EOL RESISTOR j 4 NO 2 COMMI O NC \ NO I s k R 9 • END OF LINE RELAY (EOLR-1 OR EQUIVALENT FIRST / LAST SOUNDER SOUNDER (+)POWER BASE BASE Ha wy (-)POWER NQ tTHIS IS A STANDARD RELAY M MODULE CONFIGURED TO °e REVERSE THE POWER ' GROUPING OF UP TO 6 MODEL B200SR SOUNDER BASES C0970-10 SS-450-001 3 I56-3392-003R . .. . . ...... . .. ...... • 1 .. • . . 0 : 0 0 . ... . ..... . . ..... • . . ...... .. .. .. .. ...... ...... . . . . •0000: . . • . • • . . • • 0060 Please refer to insert for the Limitations of Fire Alarm Systems THREE-YEAR LIMITED WARRANTY System Sensor warrants its enclosed smoke detector base to be free from defects in mate- Department, RA a , 3825 Ohio Avenue, St. Charles, IL 60174. Please include a rials and workmanship under normal use and service for a period of three years from date note describing the malfunction and suspected cause of failure. The Company shall not of manufacture. System Sensor makes no other express warranty for this smoke detector be obligated to repair or replace units which are found to be defective because of damage, base. No agent, representative, dealer, or employee of the Company has the authority to unreasonable use, modifications, or alterations occurring after the date of manufacture. increase or alter the obligations or limitations of this Warranty. The Company's obligation In no case shall the Company be liable for any consequential or incidental damages for of this Warranty shall be limited to the repair or replacement of any part of the smoke breach of this or any other Warranty, expressed or implied whatsoever, even if the loss detector base which is found to be defective in materials or workmanship under normal or damage is caused by the Company's negligence or fault. Some states do not allow the use and service during the three year period commencing with the date of manufacture. exclusion or limitation of incidental or consequential damages, so the above limitation After phoning System Sensor's toll free number 800-SENSOR2 (736-7672) for a Return or exclusion may not apply to you. This Warranty gives you specific legal rights, and you Authorization number, send defective units postage prepaid to: System Sensor, Returns may also have other rights which vary from state to state. SS-450-001 4 I56-3392-003R c2009 System Sensor DN-60429: C 1 DNR(A)/DNRW InnovairFlex Intelligent Non -Relay Photoelectric Duct Smoke Detector 0 NOTI FI E R' by H n n eywe I I Intelligent Devices The Notifier InnovairFlex® DNR(A) intelligent non -relay photo- electric duct smoke detector and DNRW watertight non -relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -4°F to 158°F (-20oC to 70oC), and a humidity range of 0 to 95 percent (non -condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sensor cover. The Notifier InnovairFlex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Notifier InnovairFlex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. Features • Photoelectric, integrated low -flow technology. • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/s). Specifications • Size: (Rectangle) 14.38 in (37.q"),I.gngth; 5' IfL r1,2:7 cm) • • • • ; • Width, 2.5 in (6.6 cm) Depth. • • • • • Size: (Square) 7.75 in (19.7 cm) Leggtll; 9 in (22.9 crr4) Width; : • • • •: 0600 2.5 in 6.35 cm Depth. ' 0 Weight: 1.6 lb (0.73 kg). • • • • • • • • 06000 • Operating Temperature Rang84 -4T to 1581' (-2G°C to"";' 70°C). •••••• Storage Temperature Range:'-22°F'to 15$°F. j-3Q°C t000e"o 70°C). • • • • Operating Humidity Range: 0°j io 9*5% reljtive %midity' (non -condensing). 0000 Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s). • Versatile mounting options: square or rectangular configu- Accessories ration. • Broad ranges for operating temperature (-4°F to 158°F, - 20°C to 70°C) and humidity (0% to 95% non -condensing). • Patented sampling tube installs from front or back of the detector with no tools required. • Cover tamper signal. • Increased wiring space with a newly added 3/4" conduit knockout. • Available space within housing to accommodate mounting of a relay module. • Easily accessible code wheels on sensor head (sold sepa- rately). • Clear cover for convenient visual inspection. • Remote testing capability. • Requires corn line power only. • Accommodates the installation of an addressable relay module, sold separately, (FRM-1 or NC-100R) for applica- tions requiring a Form-C relay. Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visi- ble and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W)s with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote -test -capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RA100Z OmA 12 mA Max RTS151/ OmA 12mA Max RTS151KEY Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL: S911, S3705. • ULC: S635. DN-60429:C1 •4/19/2012 — Page 1 of 2 • CSFM: 3242-1653:0209. • FM approved. Product Line Information NOTE. 'A suffix indicates ULC listed model. DNR(A): Intelligent non -relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non -relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). FSP-851 R(A): Remote test capable addressable low -profile photoelectric smoke detector. FSP-851(A): Addressable low -profile photoelectric smoke detector. NP-100: Addressable low -profile photoelectric smoke detector for Fire Warden series panels. NP-100R(A): Remote test capable addressable low -profile photoelectric smoke detector for FireWarden series panels. DQQ" Remote test coil. Required for older DNR(W) duct ...... detectorshousing. . ... . • D$T1�Q�): Metal sah}p Ag tube duct width up to 1 ft (0.3m). • : • • • • 1301a5(A): Mete* sampling tube duct widths up to 1 ft to 2 ft . (0.3.to 0.6 m). ..:... • • ..... D9 T 3(Ar Metalsafnpti �g tube duct widths up to 2 ft to 4 ft (0.6 to 1.2m). •..• • • • • • • ...... QS15(Al: Metalr"nflr?g tube duct widths up to 4 ft to 8 ft (1.2 to 42.491"). .. •• • • DST10(A): Met$I-.tAtDng tube duct widths up to 8 ft to 12 ft •••••• (2to3). !7m• • .•t ;....; DH400(FF=-1: Wi tperpgoof enclosure. • • FtTX gME;al exhaust tube duct, width 1 ft (0.3 m). M02-04-00: Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z(A): Remote annunciator alarm LED. RTS151(A): Remote test station. RTS151 KEY(A): Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Notifier® and FlashScan@ are a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 'SO 9oo1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. RM 9161NESINC A MANINICTAAINC QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-60429:C1 •4/19/2012 DN-6724:63 FCM-1(A) & FRM-1(A) Series Control and Relay Modules General FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1(A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry -contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry and relay powered directly by two -wire SLC loop. The FCM-1(A) module requires power (for horns, strobes, etc.), or audio (for speakers). • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. • LED blink may be deselected globally (affects all devices). • High noise immunity (EMF/RFI). • The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. • Direct -dial entry of address 01— 159 for FlashScan loops, 01 — 99 for CLIP mode loops. • Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1(A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four -wire smoke detector power. NOTE: Refer to the SLC Manual (FIN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-I-REL datasheet (DN-60390) for new FlashScanO releasing applications. Construction • The face plate is made of off-white heat -resistant plastic. • Controls include two rotary switches for direct -dial entry of address (01-159). �J NOTIFIERH' by Honeywell Ttl E.1 PVYi11-1 ® n TIC E.~(-) °1f Imm sees • • FCM-1(A)- • • • sees.• • 00 so 00 The FCM-1(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification A pli;noe Circuit. The FRM-1(A) provides two For C dry :oohteets that switch together. . • Operation • • • • Each FCM-1(A) or FRM-1(A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) • • • • • • • DN-6724:B3 •2/17/2011 — Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and T11): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non -condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM-1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). 44fdIr99e• operating current: 230 pA direct poll; 255 pA group polt • • see• E0�?r4sistand: not used. Temperature r an�lel �2°F to 120°F (0°C to 49°C). Humidity range:.1Q°6 to 93% non -condensing. dimensions: 4.5"•(444.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mrpt 4%9p• Mounts to a 4" (101.6 mm) square x ?•.125�'153.975 t"ldrgp box. Acoessories: SM"QG Electrical Box; CB500 Barrier • • • Ayd4y Listings and Approvals • • • IV%,bVie;cases,•certalfl modules may not be listed by certain apprwel agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635 • ULC: S3705 (A version only) • FM Approved • CSFM: 7300-0028:0219 • III 14-00-E • FDNY: COA #6067, #6065 Contact Ratings for FRM-1(A) Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non -Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non -Coded .9 A 125 VDC Resistive Non -Coded A 30 VDC Inductive Coded .5 (UR=5ms) 1 A 30 VDC Inductive Coded (UR=2ms) .3 A 125 VAC Inductive Non -Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non -Coded Inductive .7 A 70.7 VAC (PF=0.35) Non -Coded Inductive 2 A 25 VAC (PF=0.35) Non -Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: `A"suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface -Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power -limited and non -power limited wiring in the same junction box as FCM-1(A). NOTE. For installation instructions, see the following documents: • FCM-1(A) Installation document 156-1169. • FRM-1(A) Installation document 156-3502. • Notifier SLC Wiring Manual, document 51253. Notifier@ and FlashScan@ are registered trademarks of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 'SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINESINC I MMIFACTUINC QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - DN-6724:133 •2/17/2011 DN-6726:A • H-240 NBG-12LX Addressable Manual Pull Station General The Notifier NBG-12LX is a state-of-the-art, dual -action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi - flush mounted. Semi -flush mount to a standard single_ gang, double -gang, or 4" (10.16 cm) square electrical box. • Smooth dual -action design. • Meets ADAAG controls and operating mechanicsms guide- lines (Section 4.1.3[131); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG-12LX stations per loop on CLIP protocol sys- tems. • Up to 159 NBG-12LX stations per loop on FlashScanO pro- tocol systems. • Dual -color LED blinks green to indicate normal on Flash- ScanO systems. Construction Shell, door, and handle are molded of durable LEXANO (or polycarbonate equivalent) with a textured finish. Specifications • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC. • Maximum SLC loop current: 375 pA. • Ambient Temperature: 32°F to 120°F (0°C to 49°C) • Relative Humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90oF ± 3°F) • For use indoors in a dry location �J NOTIFIER`' by Honeywell The NBG-42L•X • Addressable Manual•Pell Station • • • Installation • • • • • • . • •• •• •• •• The NBG-12LX will mount semi-C&h:iMit a single-gtng, dou- • • ble-gang, or standard 4" (10.160cm) square ete trice I outlet • • • • • • box, or will surface mount to the•modei SB-10 or Walt sur . • face backbox. If the NBG 12LX %b,-Ind;semi-fWsh mounted, then the optional trim ring (BG12TR) may NJer ��S�Q. The BG12TR is usually needed for semi -flush mounting with 4" (10.16 cm) or double -gang boxes (not with single -gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 on FlashScanO systems, 1 - 99 on CLIP systems ). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non -coded, with a key - operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red -colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi -flush mounting on a standard single -gang, double -gang, DN-6726:A • 02/05/2008 — Page 1 of 2 or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual -action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-UO: Surface backbox; plastic. • • . E :1••?�•3 4 IA 1 • • 40 CD • ACk of station without door Terminal Connections: 1 SLC (-); 2 SLC (+) BG12TR: Optional trim ring. 17021: Keys, set of two. NY -Plate: New York City trim plate Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S692 (listed for Canadian and non -Canadian applications) • MEA:67-02-E • CSFM:7150-0028:199 • BSMI: C1313066760047 • U.S. Coast Guard: 161.002/23/3 (AFP-200); 161.002/27/3 (AM-2020/AFP-1010); 161.002/42/1 (NFS-640) • Lloyd's Register: 02/6007 (NFS-640); 94/60004 (E2) (AFP-200); 03/60011 (E1); 07/60007 (NFS2-3030) • FM Approved 7, Detail of BREAKAWAY TAB* 9 n 15 0 ADDRESS_ 0 14 1 1 0 0 � NI H8U9 MWW JJU9J�U9 o l�T -1 `00"" 3 Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. 1303212 123 3 114 _OOP 54 g 8 7 9 8 7 6 LED ROTARY DECIMAL SWITCHES Remove tab to select addresses above 99 (FlashScan systems only). Notifier@ and FlashScan@ are a registered trademarks of Honeywell Interna- tional Inc. LEXAN@ is a registered trademark of GE Plastics, a subsidiary of General Electric Company. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MCINERINC I MNdFACTIMYC QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6726:A • 02/05/2008 dn-6720:131 • H-220 FMM-1(A), FMM-101(A)5 �J NOT 1 F 1 E R, FZM-1(A) & FDM-1(A) Monitor Modules with FlashScan® by Honeywell Intelligent/Addressable Devices General Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry -contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two -wire smoke detectors (FZM-1(A)). FMM-1(A) is a standard -sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry -contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super- vises a Style B (Class B) circuit of dry -contact input devices. Its compact design allows the FMM-101(A) to often be mounted in a single -gang box behind the device it monitors. FZM-1(A) is a standard -sized module that monitors and super- vises compatible two -wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard -sized dual monitor module that moni- tors and supervises two independent two -wire Style B (Class B) dry -contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two -wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FMM-1(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two -wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct -dial entry of address: 01 — 159 on FlashScan loops; 01 — 99 on CLIP loops. • LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two -wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two -wire or four -wire fault -tolerant Initiating Device Circuit (IDC) for normally -open -contact fire alarm and supervisory devices. The module has a panel -controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally - open dry -contact alarm activation devices. May also be used to monitor normally -open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class k -ir I • • e • • .. • • • FMM-1(A) (Tppe•W) • • • • ••...• A) Initiating Device Circuit. A 47"4l"O.End-of;-Ine, R$sistor' • •"• (provided) terminates the Style •B •Aircuit. Nct •re"or is • • • • 9 • required for supervision of the Stylo C"rcuit. 1 • • FMM-1(A) OPERATION • • :.. •: • • • Each FMM-1(A) uses one of theeavaifabte module addresses • • • • • • on an SLC loop. It responds to regular polls from the sontrol panel and reports its type and the status (open/r1bTM I/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 320F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FMM-101(A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two -wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • Tinned, stripped leads for ease of wiring. dn-6720:B1 • 11 /19/09 — Page 1 of 4 • Direct -dial entry of address: 01 — 159 on FlashScan loops; 01 — 99 on CLIP loops. 3 1415 0 1 ADDRESS 0 1 2 2 1 2 3 �O 4 LOOP O 4 109 5 8 7 69 8 7 65 TENS ONES O uJ —1 Q _O Co The FMM-101(A) Mini Monitor Module can be installed in a singleyang junction directly behind the monitored unit. Its sAjII,5i4e and ligIV weight allow it to be installed without rigid moWnt". The F:AM -,12t(A) is intended for use in intelligent, two -wire systems where the individual address of each module is selected using roVrr� Switches. It provides a two -wire initiat- ing device circuit*lbf Ontrmally-open-contact fire alarm and security devices.. •-FtV_+ F MM-101(A) can be used to replace MW-T6;A) modules in existing systems. FNM-1b4(A) AASUMT1ONS 00 Use to monitor a sincle device or a zone of four -wire smoke detectors, manuViie alarm pull stations, waterflow devices, or otljr pprl�ally-open dry'contact devices. May also be used to monitor nOrmallyid4n sppervisory devices with special super- visery indicationet tt"control panel. Monitored circuit/device is VA'A s an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End -of -Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1(A) Interface Module • Supports compatible two -wire smoke detectors. • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct -dial entry of address: 01 — 159 on FlashScan loops, 01 — 99 on CLIP loops. • LED flashes during normal operation; this is a programma- ble option. • LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two - wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two -wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two -wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End -of -Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 320F to 120OF (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM1(A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two -wire systems. It provides two independent two -wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor - Page 2 of 4 — dn-6720:61 • 11 /19/09 mally closed security devices. The module has a single panel - controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing) Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non -condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. ACAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face -mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power -limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635 • ULC: S635 • FM Approved • CSFM: 7300-0028:202 (For Domestic only) • MEA:457-99-E • U.S. Coast Guard: — 161.002/23/3 (AFP-200: FMM-1/-101, FZM-1) — 161.002/42/1 (NFS-640: FMM-11-101) • Lloyd's Register: — 03/60011/E1 (FMM-1/-101, FZM-1) — 94/60004/E2 (AFP-200: except FDM-1) — 02/60007 (NFS-640: FDM-1) Product Line Information NOTE: 'A" or suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two -wire detectors. FDM-1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface -mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. dn-6720:B1 • 11 /159/09 — Page 3 of 4 ...... .... . . ...... . .. ...... ...... ... . a ..... . .... ..... . . ...... . . ...... . .. .. .. .. ..... . . . . . . . • . 0000 . • • FlashScan@ and NOTI FI ER® are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. @2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENBINEEMNi U MANUFACTOM U All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4 — dn-6720:61 • 11 /19/09 DN-6755:A PAM-1, PAM-2, and PAM-4 4NOTI FI E R° Multi -Voltage Relay Modules by Honeywell General Air Products & Controls, Inc. PAM-1, PAM-2, and PAM-4 Multi - Voltage Relay Modules are encapsulated multi -voltage devices. The PAM-1 relay provides 10.0 Amp Form-C contacts and may be energized by one of three input voltages: 24 VAC, 24 VDC, or 115 VAC. The PAM-2 relay provides 7.0 Amp Form-C contacts and may be energized by one of two input voltages: 12 VDC or 24 VDC. The PAM-4 relay provides 10.0 Amp Form-C contacts and may be energized by a wide voltage range from 9 VDC to 40 VDC. A red LED is provided on both models. When illuminated, it indicates the relay coil is energized. Either model may be mounted by using the double -sided adhe- sive tape, the self -drilling screw, or by placing loosely in a backbox. PAM-1, PAM-2, and PAM-4 Relay Modules are ideal for appli- cations where remote relays are required for control or status feedback. They are suitable for use with HVAC, temperature control, fire alarm, security, energy management, and lighting control systems. Specifications Power requirements: • PAM-1: 0.015 Amps per position @ 24 VDC, 24 VAC, 115 VAC. • PAM-2: 0.015 Amps per position @ 12 VDC or 24 VDC. • PAM-4: 0.015 Amps per position @ 24 VDC or 12 VDC. Relay: UL-recognized SPDT. Contact Rating: • PAM-1: 10.0 A @ 115 VAC, 7.0 A @ 28 VDC, 250uA @ 5 VDC. • PAM-2: 7.0 A @ 115 VAC, 7.0 A @ 28 VDC, 250uA @ 5 VDC. • PAM-4: 10.0 A @ 120 VAC, 7.0 A @ 24 VDC, 250uA @ 5 VDC. Ambient Temperature Range: -58°F to 185°F (-50°C to 85°C). Dimensions: 1.5' (3.81 cm) high x 1.0" (2.54 cm) wide x 0.875" (2.223 cm) deep, with 12" (30.48 cm) wire leads @ 18 AWG (0.75 mm2). PAM-* " ' • • • 0090 • • • • Agency Listings and •gpjVbvalS••••• 0„00 • These listings and approvals app p1 •Ilh @ modules sppeoified in • • • • • this document. In some cases, caiai rrb modules or applications. • • • • • may not be listed by certain appjgy6i6 cWncies, or ll�ting may • be in process. Consult factory fo lateSt I� ting status. •.•••• • UL Listed: S3403 • • • • • MEA: 73-92-E, Volume XXI '•.' i • •• i""� • CSFM: 7300-1004:101 •: • • Product Line Information PAM-1: Single SPDT relay with LED, double -sided adhesive tape, mounting screw, 12" (30.48 cm) leads, and six wire nuts. PAM-2: Single SPDT relay with LED, double -sided adhesive tape, mounting screw, 12" (30.48 cm) leads, and six wire nuts. PAM-4: Single SPDT relay with LED, double -sided adhesive tape, mounting screw, 12" (30.48 cm) leads, and six wire nuts. DN-6755:A • 08/19/14 — Page 1 of 2 . 0 0 0 0 . Wiring Diagrams % • : 0 0 • . (—) N N H BLK ._ t Relay -Energized LED WNT 0 • �t— 115 VAC @ 0.015 Amp _24VAC@0.015Amp 24 VDC @ 0.015 Amp •00 : WI1T 0 06 V (�) +24V '....' e9eeee+'12V RED . . •• •• :0:00: (-) RED (+) BLK PAM-1 Relay -Energized LED PAM-2 Relay -Energized LED ♦_ PAM-4 BLU C YEL NC 10.0 Amp IORG NOContacts _BLU C YEL NC 7.0 Amp Contacts a�G NO BLU C YEL NC 10.0 Amp II Contacts OR NO 02014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 9ILINEENINL SAll specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6755:A • 08/19/14 ll— 000 COOPER Notification rM Strobe, Horn Strobe, and Horn E ED Notification Appliances r t Ceiling M Wall Description: The Wheelock® ExcederTI Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTm Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Compliance - UL 1971, UL 464, ULC, CSFM, FM - ADA/NFPA/ANSI/OSHA - RoHS . . sees see*:* .. .. . s . . . sees.. .. e.•.e. ••sees • • - Save up to Q$o/Qiw•aurrent draw* :0"**: sees - Up to 9 models n'd V to 1 appGahce .. .• .. .. sees•. .sees. . .' Lac/v - Save up to 1 cdst of iastaLlation:;..:. sees.. • • . • • . .s...e ee USleek Modern Aesthetics**:..* Finger Slide Switches Voltage Test Points Multiple Voltages U3 Audible Settings 90, 95, 99 dB U8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 Universal Mounting Base #" Ceiling and Wall UU Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range Compared to competitive models ** Patented " Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. L► WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32'F to 120°F (0°C to 49°C) and maximum humidity of 93% (t 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Low Current Strobe Ratings per UL Standard 1971 Draw = Fewer Power• • UL Max Current- 24 VDC / 24 FWR 12 VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 �:� • • •'j_Qy 3.0 0.(Q61 0.085 0.103 0.135 0.163 0.182 0.205 0.253 10.110 NOnn.Strobe RNrrgs per J4L• #9_A1•& Anechoic at 24 VDC ..• UL Max Current- at Anechoic 99 dBA .:...: . 24 VDC 12 VDC 1UI84el Regulated Volta". •t5 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 .... :. VDC'.. .. FiS 08.0-33.0 : • .t82 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 4M* •:.&W 33.0 � .•.. • . 0.882 0.102 0.141 0.148 0.176 UL Max Current*- 0.197 0.242 0.282 dBA 0.125 . • . • • • • • 24 • VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 = 0.230 0.272 0.122 UL Max Current* at Anechoic •0 •:• 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL Anechoic Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB FIN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 FIN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 " UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync w/ Strobe DSM or Model Candela Wheelock Power Supplies X HSR 15/1575/30/75/95/110/135/185 ' HSW 15/1575/30/75/95/110/135/185 X HSRC 15/30/60/75/95/115/150/177 X ' HSWC 15/30/60/75/95/115/150/177 X X strobes STIR� 15/1575/30/75/95/110/135/185 ' STW 15/1575/30/75/95/110/135/185 X STRC 15/30/60/75/95/115/150/177 X STWC 15/30/60/75/95/115/150/177 X X HNR • X HNW X HNRC .. HNWC m- X 12/24 VDC* Mounting Options X UMB** X UMB** X UMB** X UMB** X UMB** X UMB** X UMB** X UMB** UMB** X �..•�MB.. *12 VDC models feature 15 & 15/75 settings • • •:*iWMB = Universal Mounting Bate NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock° ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi -Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single -gang, double -gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance srgq l;psult in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all h o�rr, strobe,orn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. %e Series HS.arW.ST wall J�nolclelsshall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" , Vx J.y 8" W:t a!6.' jf. The Sp0Qr& riSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a di§rprj %r of 6.68" x 1.50" D. ;Wh2h$ynchropizatigp is requYQd,Jhe appliance shall be compatible with Wheelock®'s DSM Sync Modules, Wheelock® Power Supplies 4 r�q.% jr man&AftlEr's pan2js vyiVbuilt-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any ,time during operation. If they yni protocol fails to operate, the strobe shall revert to a non -synchronized flash -rate and still maintain (1) tias�i per secsn4 over its RuIated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced '4 1??haintaihhg'sirobe activation when used with Wheelock® synchronization protocol. �111rablepplianAes-411- Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS ;GQainb Appliances'— UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 5/13 Cooper Notification is Wheelock' ® SAFEPATH' WAVES, Notification COOPER Notification Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories Description: Designed for life safety, performance and reliability, Cooper Wheelock's cost effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes RSSWP Horn Strobes ASWP Horns AH-24WP, AH-12WP Multitone Horn Strobes MTWP Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper -Wheelock provides the industry's widest choice of mounting options for surface or unique semi -flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (1013, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi -flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. � L �_�� �. FM ® M".EA APPROVED E5946 151-92-E 7125-0785:131 (ASWP) S5391 7125-0785:146 (ET70WP) S2652 7125-0785:156 (MTWP) 7300-0785:154 (RSSWP) •Yi• • • •••• •••••• • *00*00 All models may be synchropi�o yising the Wpeelock �M, DSM Sync Modules, Wheelock Power Supplies or other manufaett r4s panels incorporating the Whee%A&Patented•S;rs Protocol. TRe horn output of horn strobes tAfT be indel?endently contfdlW gn 2-wire circuits using the WhA21oCk'QatenteV%ypcprotoc01offl4r VP horn strobe models are 4-t*e•applianceseethe•strobeseam•be synchronized while the aud"Eosanbe connected to a coded lire alarm system or can be A to•praduce any of eight wLer4Ze tones. • • • • • • . • . • .00. . • • •••• Features: • Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP) . See agency approvals by model number on page two of this document • Compliance with the following requirements: NFPA, UFC, ANSI 117.1, OSHA Part 29, 1910.165, ADA • Weatherproof with extended temperature range of —40°F to 150OF (-40°C to 660C)* • Dual Listed strobe models (UL 1638 and UL 1971) • Industry's highest strobe candela options • Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol • Models with field selectable tone, dBA and candela settings • Wall or ceiling mounting options • Surface of semi -flush mounting • IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal 'The series RSSWP, ASWP, MTWP and ET70WP have UL approval down to -40°F. The AH-24WP, MT-12/24 and the ET-1010 have been ULC tested and approved to -40°F, but not submitted to UL. The AH-12WP has UUULC approval to -31°F. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. • All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount Ceiling Mount RSSWP MTWP RSSWP MTWP F ARE ASWP ET70WPJ ASWP ET70WP Strobe 06404 Order Code Strobe Order Code RSSW -2475W*FR • • Red •9013 • RSSWP-2475C-FR Red 4338 R:§-2475W-F�/ White • 3034 • RSSWP-2475C-FW White 4446 RtjSWP-24MC4A fft' ged ' 51E? RSSWP-24MCCH-FR Red 5167 RGWAP•24MCW14-FO1 White • "69 • RSSWP-24MCCH-FW White 5187 • D4Strobe ` ••"'' Audible Strobe WP-2475W-Fl? Red 1002P ASWP-2475C-FR Red 4251 A$\4VW,VMCHIiFR' • Qed "Z3 ASWP-2475C-FW White 4502 AW� - 4 MCWTFW • White • J5j4Q • ASWP-24MCCH-FR Red 5149 e Stro ' ' ' ' ASWP-24MCCH-FW White 5157 09*0 MiWP-2475W-FR • Red •.8. jq . Multi -tone Strobe MJ*P-2475W-FW White • 3Al2 • MTWP-2475C-FR Red 4457 RltbA-AMCWy -::R • Ded • 5132 ' MTWP-2475C-FW White 4478 MTWP-24MCWH-FW White 6134 • MTWP-24MCCH-FR Red 5102 3peake�"Strobe.' • ; • • • • • MTWP-24MCCH-FW White 5122 ET70WP-2475W-FR • • Red 9077 Speaker Strobe ET70WP-2475W-FW White 3179 ET70WP-2475C-FR Red 4452 ET70WP-24185W-FR Red 4885 ET70WP-2475C-FW White 4454 ET70WP-24185W-FW White 4891 ET70WP-24177C-FR Red 4845 ET70WP-24135W-FR Red 4872 ET70WP-24177C-FW White 4859 ET70WP-24135W-FW White 4875 ET70WP-24115C-FR Red 4550 ET70WP-24115C-FW White 4732 Candela Ratings Series UL 1971 UL 1638 @ 77°F UL 1638 @ -40°F RSS, ET70WP and MTWP UL Max Current Strobe Only) ASWP High Med Low 2475 30** 180 115 0.138 0.168 0.155 0.150 135 135 56 0.300 0.355 0.340 0.335 MCWH 185 185 77 0.420 0.480 0.465 0.460 115 115 47 0.300 0.355 0.340 0.335 MCCH 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 **Wall mount rating only 24177 177 177 73 0.420 UL Max. Current (Audible) MTWP/MT 24 VDC MT 12 VDC BA HI STD HI STD Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 Code 3 Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Hi/Lo 0.057 0.025 0.114 0.026 Wall or Ceiling Mount E a MT AH ET-1010 Audible Order Code AH-24WP-R Red 7416 AH-12WP-R Red 7415 Horn MT-12/24-R Red 5023 Speaker ET-1010-R Red 3135 ET-1010-W White 3137 UL Max. Current AH 24 VDC 12 VDC High (99) dBA 0.080 0.192 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 UL Reverberant dBA @ 10 Feet Watts 1/8 1/4 1/2 1 2 4 8 ET-1010 77 80 83 86 87 92 94 ET70WP 78 81 84 87 190 93 95 Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X RSSWP-24MCWH X * X RSSWP-24MCCH X X Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X * X ASWP-MCCH X * X Multitone Strobe M-FWP-2475 X X X X MTWP-MCWH X * X MTWP-MCCH X * X Horns/Audibles AH-24WP X X X X AH-12WP X X X X MT-12/24 X X X X X Speaker Strobe ET70WP-2475 X X X ET70WP-185 X X ET70WP-177 X X ET70WP-115 X * X ET70WP-135 X * X *Pending Mounting Accessories Cl oniv* a Gasket Kit WP-KIT Flush Plates WFPA-R WFPA-W WFP-R WFP-W Backboxes 10B-R 10B-W WPSBB-R WPSBB-W WPBB-R WPBB-W WBB-R WBB-W Wiring Diagrams WFP WFPA Order Code 4486 Red 4698 White 4701 Red 4696 White 4697 Red 5046 White 5047 Red 9751 White 3033 Red 9014 White 4692 Red 2959 White 2960 1013 WPSBB WPBB WBB Mounting Options: Backboxes, Plates, Gasket Kits Surface Mount Flush Mount Exposed Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WFP ET70WP Speaker Strobes 1013 1013 + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA AHWP Horns WBB - • • • • WFP ET- 1010 Speakers WBB • • -` • • • •' WFaR SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT -WIRES ARE SUPPLIED. FROM❑ + +L_,TO NEXT❑ PRECEDING APPLIANCE'._- APPLIANCE RED — —[1OR EOLRE OR FACP BLAcxi_: STROBE- AUDIBLE__ SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12/24 APPLIANCES FROM❑ + +❑ TO NEXT' PRECEDING❑ _ —[]APPLIANCE] APPLIANCE ORE OR EOLRE FACP❑9f. �. • FP •• • • • " • •••••• ••••• • ••••• •••••• • SERIES MTWP APPLIANCES CHRO,NIZED STROBE.• OPERATION WITH CODE4FACQ we """ • MTu i • • • • i •• 01• Strobe Sys Circui = MOduleD NAC N1_, PS-12/24- Audibl - Pow _ Circui 11 FAC P Supply NAC N2 Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED W/ • FP •• • • • " • •••••• ••••• • ••••• •••••• • SERIES MTWP APPLIANCES CHRO,NIZED STROBE.• OPERATION WITH CODE4FACQ we """ • MTu i • • • • i •• 01• Strobe Sys Circui = MOduleD NAC N1_, PS-12/24- Audibl - Pow _ Circui 11 FAC P Supply NAC N2 Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED W/ DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM❑ STROBE- +: jo NAC.-. SYNCC -� CIRCUIT- 0- 0 'RSS- FAC P' E_OMINUS RSS1 RSSTROBE[ NAC-1 CIRCUIT- RETURNC Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi -flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of-40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectab4'faps,.for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back 'C&fSttction fcfle }a proter11an add improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to prodVej tip to 94 CBA tMd shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series PCT-A 11A/P. Thershell be availettle4fer surface or semi -flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. :31114onizatlpn Modules"::::* When synchreeittr*r of stiOpg§ pttemporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series .0; MM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The Mdeb'et and kdible%shall r0edsi out of synchronization at any time during operation. 9e�ries ASWP aVibles and gtrpl;P,%shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT rrultitonP audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a lose circuigirow the audibles while the audible circuit is connected to a coded or continuous NAC. :0694• • • • W1Meathierproof"quilting AtceMries Weatherproof moor►ting options shall include surface mounting or semi -flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock 1013, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi -flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. A WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S9004 WP 05/08 Cooper Notification is Wheelock* MEDC SAFEPATH` WAVES,S ) Notification . . .... ...... ...... .. . ...... .... '04& .... . ..... .. .. .. .. ...... AOVANCaM F=1FRE Et SECURITY • • ' ' •..• 2701 GATEWAY DRIVE •• ••�••• POMPANO REACH. FLORIDA 33069 • • • • • August 7, 2019 Phone: (954) 772-1700 - (954) 772-0500 FAX (954) 772-0050 STATE & U.L. CERTIFIED STATE LICENSE EF#0001162, EF#20001066, EF#20001414 U.L#S7195.1 NARRATIVE RE: BARRY UNIVERSITY — WEBER HALL 1ST, 2ND FLOORS BASEMENT 11300 NE 2ND AVE. MIAMI SHORES, FL. 33161 RE: Permit Number Miami Dade County Building Department. 11805 SW 26" St. ' Miami, FL 33175 Please find with this letter, two sets, signed and sealed fire alarm drawings for BARRY UNIVERSITY — WEBER HALL 1ST, 2ND FLOORS BASEMENT 11300 NE 2ND AVE. MIAMI SHORES, FL. 33161 Plans are for corrections for fire alarm plans, Delta 2. Cut Sheets — Devices 1. Battery calculation's added to plan 2. Panel is an AFP-400, please see updated legend, calculations and data sheets. 3. Existing NAC Calculations are correct and match the riser diagram. Circuits #1 & #2 are spares, only 3, 4 are used. 4. Added an Altronix Power Supply to some of sounder bases to bring down load on FACP. Please see scope of work for max. devices on Panel. 5. Please see attached certificate and affidavit. 6. Please see revised sequence to show added door holders. Device Cut Sheets. Renumbered rooms. Updated notes, riser diagram, legend and calculations. PLANS CLOUDED AND DELTA 2 Sincerely, dwp,@advfireonline.com F.A Drafter Advanced Fire & Security, Inc. Ph:954-772-1700 ape OEpT. Miami -Dade Fire Rescue Fire Alarm Pre -Submittal Checklist Based On NFPA 72 2010' Ed. & NFPA 1 and 101 2012' Ed. ...... ZDADF9�. MIAf4I •••• Building Dept. Process Number is (Begins with C or M): • • ..Date: •���/201tiJ • 1 Project Name: BARRY UNIVERSITY - WEBER HALL is provided in title blIA00tMns. YES 1, A 2 Address in title block shall match address in "Building Dept. Computer System" and attached permit application. If address cont- r1s• • ✓ , • a specific building, floor, suite, or unit number or letter, it shall be provided in title block, to match Building Dept:CorytSuter System. • • • • The total cost of the installation to the customer is $ 9,443.86 and a copy of the contract or a notarized • ✓ 3 • • affidavit from the owner showing this amount is attached. 4 Fire Alarm Systems costing more than $5,000 are sealed or stamped by a Florida Registered Professional Engineer. 5 The total number of DEVICES and COMPONENTS being installed is 71 ✓ 6 The alarm qualifier's state license number is (EC EF)EH EY) # 20001414 and a copy is attached to plans. ✓ 7 Complete, current Manufacturer's Specification and Installation sheets are attached for all Control Units, Components, Appliances, Devices, Modules and Relays listed on Legend. ✓ 8 Is this permit application for fire alarm work a result of a Notice Of Violation (NOV) issued by Miami -Dade Fire Rescue? If yes, a copy of the Notice of Violation is attached. ✓ This fire alarm: l/J is required under Chapter 29 (fill in the Occupancy Chapter & Section from NFPA 101) or, 9 (_) is a life safety equivalency or, (_) is a non -required system or component. This is an "EXISTING (Local) Fire Alarm System" and is stated as such on the plans. AHJ will require documentation of prior 10 approval of system as a (Local) Fire Alarm System in the form of the original Fire Dept. approved job copy set of fire alarm plans or, certified microfilm copy of same. 11 This is a "NEW Local Fire Alarm System" and is stated as such on plans. This is an "EXISTING Central Station Service Fire Alarm System" and is stated as such on the Plans. A copy of the existing 12 BUILDING UL or ETL certificate or FM Placard, specifically identifying this protected premise by address and, uniquely identifying ✓ this building's fire alarms stem, is attached. If the company that issued the existing certificate or placard for this building's fire alarm system is different than the company 13 applying for this permit; is the required Affidavit to Work on another Company's Certificated or Placarded Fire Alarm System Provided. 14 This is a NEW Certificated or Placarded "Central Station Service Fire Alarm System" and stated as such on the plans. 15 If this is a NEW "Central Station Service Fire Alarm System," a copy of the UL or ETL certificate of FM placard from the contractor or, from the Central Station Service Company, issuingthe buildingcertificate/ lacard, is attached. ✓ This is an "EXISTING Remote Supervising Station Fire Alarm System" and is stated as such on the plans. AHJ will require 16 documentation of prior approval of system as a Remote Supervising Station Fire Alarm System in the form of the original Fire Dept. I/ approved job copy set of fire alarm plans or, certified microfilm copy of same. 17 This is an "EXISTING "Sprinkler Waterflow and Supervisory System" only and is stated as such on plans. This is a NEW "Sprinkler Waterflow and Supervisory System" only and is stated as such on plans. The system is monitored off -site 18 and provides emergency forces notification through a Certificated (_) or Placarded "Central Station Service Fire Alarm" and is stated as such on the plans. A complete detailed statement of the "SCOPE OF WORK" is stated on the plan. Please note that the complete tenant space, in its 19* entirety, will be inspected for compliance with NFPA 72 (2010) and NFPA 101 (2012), or prior editions of these codes if applicable. ✓ Also outline scope of work with bolded dashed lines on floor plan and riser for existing systems. 20 1 The building is "Nev/' or, "Existing" and is indicated as such on the plans. 21 A description of the building is provided, including fire sprinkler systems, fire suppression systems, number of stories, square footage per floor, and elevation of the last occupied floor if over 5 stories. ✓ 22 A location Key is provided showing the area of proposed work within the building. Also provided is a site key for projects with multiple buildings showing locations of all buildings with addresses ✓ 23 All interconnected Fire Alarm Control Panels are arranged to function as a single system and monitored for integrity er NFPA 72. 24 The Class is shown for all Initiating Device Circuits (IDC), Signal Line Circuits (SLC) and Notification Appliance Circuits (NAC). 25 The maximum number of each device type is provided for each IDC based on device load or each SLC, based on CLASS, per NFPA 72 and the manufacturer's specifications. ✓ 26 A specific "Sequence of Operation" including all alarm, supervisory, trouble and control functions such as fire sprinkler, door release, smoke control, elevator recall, suppression systems, and transmission of signals offsite, etc. are specified on the plan. ✓ 27 The type of monitoring station, (Listed Central Station, Remote Supervising Station, Listed Proprietary Supervising Station), where alarm, trouble, and supervisory signals are transmitted to, is clearly and concisely stated in the "Sequence of Operations" ✓ 28 The method of communication to the monitoring station is included on the riser. 29 If this building contains elevators that are not capable of recall, it shall be stated as such on plans and written documentation on elevator contractor's letterhead stating that "Elevators are not capable of providing recall function", is provided, ✓ 30 If this building does not contain a fire alarm system, and the fire alarm panel is used exclusively for elevator recall; plans shall clearly designated panel as "Elevator Recall Control and Supervisory Panel" ✓ 31 Manufacturer, model number and unique symbol for each model number is provided for each device, module, relay, component, power supply and fire alarm control panel is specified in the symbol legend. ✓ 32 Each device, module, appliance and component is identified with its own unique number and indicated on the floor plans and riser. ✓ 33 Floor plans are drawn to 1/8" scale or, if using another scale, all device coverage is diagrammed on the floor plan and all room dimensions are included. ✓ Designed by: Advanced Fire & Security, Inc Phone #: 954-772-1700 Signature: Angel Lopez Created by: MDFR 01 / 2015 THIS IS A REQUIRED DOCUMENT ON ALL FIRE ALARM PLAN SUBMITTALS 1 OF 2 ...... .... . . Miami -Dade Fire Rescue ••••-�-+ �z ...... Fire Alarm Pre -Submittal Checklist _ �`; . • ; • • • • • • Based On NFPA 72 2010' Ed. & NFPA 1 and 101 2012' Ed. • • • f1 � COUNTY 0• 14M rooms.9.speces are la yyiicating their use, and the occupant load has been provided for all assembly use rooms with an ✓ • occupant Io of 50 or r t r. �I new, exjsting,replaceil oibre ocated devices are indicated on the floor plans and a complete riser diagram showing all new and ✓ existinq dewicosof the entire fire Alarms stem is provided. oWo iling Height, Tfpe and le i3 rovided for all ceiling mounted devices. ✓ 37 I devices•Jl cpmponents looeted in areas in which the voltage, temperature, and humidity variations exceed those conditions ✓ stated in WoPA.72, are listed for conditions and all such areas are identified. 38 A note is provided on the plans stating "Room containing FACP, Booster Power Supply, Voice Evacuation and Amplifier panel(s), ✓ Dialer, or Radio is mechanical) ventilated", as applicable. 39 The FACP or Remote Annunciator and as applicable EVAC panel or Remote Microphone is located at the main entrance/lobby in ✓ single tenant buildings, or in a common area main entrance/lobby of a multi -tenant building. 40 The FACP, Communicators, Amplifiers, NAC Panels and all sub -panels are protected with a smoke detector. ✓ 41 If a complete automatically activated system, not less than one manual fire alarm pull box shall be provided to initiate system. The ✓ pull box shall be located where AHJ specifies. 42 If a manually activated system, the travel distance to reach a pull station is less than 200' feet and within 5' feet of all required floor ✓ and/or building exits. 43 All automatic initiating devices are shown and are located in accordance with NFPA 72, the manufacturer's specifications, and ✓ accepted engineering ractices. 44 Area smoke detectors, if used, shall provide coverage throughout the entire smoke compartment. ✓ 45 All visual notification appliances are placed per tables in NFPA 72 and each strobe has its candela rating on the floor plan and riser. ✓ 46 All corridor spaced strobes are placed a maximum of 100' feet apart and within 15' feet from the ends of the corridor. ✓ 47 1 All spaces throughout the entire building shall meet the audible characteristics of NFPA 72 and NFPA 101. ✓ 48 Where audible appliances are provided to produce signals for sleeping areas, they shall produce a Low Frequency Alarm Signal, ✓ per NFPA 72.18.4.5.3. 49 Bell used for water flow annunciation is shown on floor plan, riser and legend. Bell shall be located so as to be visible and heard ✓ from roadway or parking area, within close proximity to Fire Dept. Connection (FDC). 50 Flow Bell sequence of operations shall state as follows: A) Flow bell shall activate upon water flow only. B) Flow bell shall continue ✓ to sound as long as water is flowing. C FACP shall not be capable of silencing Flow Bell. 51 The location of Backflow Preventer (BFP) and Post Indicating Valve (PIV) are indicated on the floor plans, riser and legend for ✓ sprinkled buildings. Also, the location of the Fire Dept. Connection (FDC) is shown on floor plans. 52 Walls, partitions, racks, shelves and equipment that do not extend to ceiling, are shown with their heights indicated on floor plan. ✓ Duct detectors or relays for duct detectors are shown on the floor plan and riser for all systems over 2000 CFM supply or 15,000 53 CFM return. Duct detectors shall derive their 24 vdc power source from the Fire Alarm System to satisfy the monitoring for integrity ✓ requirements of NFPA 72.10.17, for devices and conductors. Please show compliance on riser. 54 A complete system riser diagram is provided showing each floor of the building with all zones and circuits labeled. ✓ 55 The conductor size, type, and quantity are provided for each circuit on riser. The fire pump is monitored for: A) Pump or Motor Running, B) Loss of phase, C) Phase reversal, and, if applicable, D) Controller 56 connected to an alternate source; and are indicated at _ a continuously manned location, or _ the supervised fire alarm ✓ system. 57 Show all relays on floor plan and clarify function on riser. (Sprinkler, Wet Chem., Dry Chem., Clean Agent, Foam, A/C shut -down, ✓ Door Release, Elevator Shunt -Trip, Music Shut -Down, Smoke Control and other building control functions. 58 The AMPACITY of each Power Supply and Notification Appliance Circuit is specified for each FACP & Power Supply Panel on ✓ tans. In addition, the individual device current is specified on riser for each notification appliance Horns / Speakers / Strobes . 59 The total "ACTUAL" footage to the last device along with voltage drop calculations are provided on plans for each NAC for each ✓ power supply. 60 The wattage tap is indicated for all speakers. 61 The wattage capacity and load is provided for each amplifier. ✓ All load values for "STANDBY" & "ALARM" used in calculations are high -lighted on the manufacturer's specification or installation ✓ 62 sheets. Also, AMPACITY of eouioment/comoonents and circuits are high -lighted on manufacturer's sheets. 63 This system includes Emergency Voice Evacuation and is provided with 15 minutes of secondary alarm power. Required in all high ✓ rises and assembly occupancies with an occupant load greater than 300. 64 This system is being provided back up power by an emergency generator and will provide 4 hours of standby power plus the ✓ appropriate secondary alarm power. Also, clarify 120 volt panels feeding Fire Alarm components, is connected to generator. 65 Battery calculations, detailed in chart form, showing all information required per NFPA 72.10.5.6.3.1 are provided on plans for each ✓ back-up power supply. The replacement of the Fire Alarm Control Panel with anything other than the exact same make and model number panel; or the 66 addition of a Fire Alarm Control Panel which will provide or replace any of the functions of the existing FACP, shall require the fire ✓ alarm system to be up -graded to current code standards, per code of Miami -Dade County, Part III, Chapter 14, Article III, Section 14-66 9 & 10 r6 71 If the scope of work includes greater than one-half of the entire fire alarm system's devices, then the entire fire alarm system shall ✓ be up -graded to current code standards, per code of Miami -Dade County, Part III, Chapter 14, Article III, Section 14-66 (9). Designed by: Advanced Fire & Security, Inc Phone #: 954-772-1700 Signature: Angel Lopez Created by: MDFR 01 / 2015 THIS IS A REQUIRED DOCUMENT ON ALL FIRE ALARM PLAN SUBMITTALS 2OF2 File No: S7195 CCN: UUFX Service Center No: 1 UExpires: 06/04/2023 L Issued:06104/2019 . . .. .... CENTRAL STATION - FIRE •••••• •••• FIRE ALARM SYSTEM CERTIFICATE (NFPA 72) THIS CERTIFIES that the Alarm Service Company is included by UL LLC in its Directory as qualified tj V s"ITe UL Lf''ark in 4 i' g I �ti�91�d .... connection with the certificated Alarm System. This Certificate is the Alarm Service Company's representation s that the Alarm System including all connecting wiring and equipment has been installed and will be maintained in compliance �vlt�t•re;uirements es tablish%q •, by UL. This Certificate does not apply in any way to the installation of any additional signaling systems, such as; fire, ;toka,-waterflow, burglary, holdup, medical emergency, or otherwise, that may be connected to or installed along with th4 Ce t1ficated Alarm System:... This Certificate does not apply in any way to the communication channel between the protected propertj 5nd 9ny facZi4fh%4 monit3rs signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified oil tt}b'Certificate. LIMITATION OF LIABILITY: UL LLC makes no representations or warranties, express or implied, that the Alarm System will in all cases prevent any loss by fire, smoke, water damage, burglary, hold-up or otherwise, or that the Alarm System will in all cases provide the protection for which it is installed or intended. By the Alarm Service Company providing this Certificate and the Protected Property acceptance of this Certificate, the Alarm Service Company and the Protected Property acknowledge and agree that UL does not assume or undertake to discharge any liability of the Alarm Service Company or any other party. UL is not an insurer and assumes no liability which may result directly or indirectly from inspection of the equipment, failure of the equipment, failure to conduct inspections, incorrect certification, nonconformity with requirements, failure to discover nonconformity with requirements, cancellation of the Certificate or withdrawal of the Alarm Service Company from inclusion in ULs Directory prior to the expiration date appearing on this Certificate. OPERATIONAL REQUIREMENTS: The Alarm Service Company bears the responsibility for the correctness of the installation; maintenance of the system documentation; periodic system inspection and testing; maintaining and providing any necessary repairs. All operations and maintenance shall be conducted in the manner prescribed by the NFPA standard referenced. All required service is to be provided for in an appropriate contract. System documentation is defined to include any "As Built Drawings", the records of any "Acceptance Testing"; and the records of all periodic system testing and maintenance. SYSTEM DESCRIPTION: This system is installed and operated in accordance with Area Covered: All Common areas,floors Authority Having Jurisdiction: Miami Dad Responding Fire Department: Miami Dac SYSTEM DEVIATIONS FROM RE Protected Property: BARRY UNIVERSITY WEBE 11300 NE 2ND AVE MIAMI SHORES, FL 33161 SN: FC112576356 NFPA 72,2016 edition. INC U Expires: 06/04/2023 Issued: 06/04/2019 Entry No: 5600830 Version: 7 ,•• '. CENTRAL STATION - FIRE • FIRE ALARM SYSTEM CERTIFICATE DESCRIPTION , FOR Certificate Serial No: FC112576359•'1•• '••••� ....; •..• .... Protected Property: Alarm Service Company:: + • • • BARRY UNIVERSITY WEBER ADVANCED FIRE & SECURITY INC* • • • 11300 NE 2ND AVE 2701 GATEWAY DR * • • 6 : • • • • • MIAMI SHORES, FL 33161 POMPANO BEACH FL 33069 • • • • Comments and Clarifications: All Common areas,floors and electrical rooms as requiered by NFPA 72 and local AHJ System Description: Area Covered: All Common areas,floors and electrical rooms as requiered by NFPA 72 and local AHJ Authority Having Jurisdiction: Miami Dade Fire Rescue Department Responding Fire Department: Miami Dade Fire Rescue Department Testing and Maintenance Contract date: 06/04/2019 SYSTEM DEVIATIONS FROM REFERENCED NFPA STANDARDS NONE, Automatic Fire Detection and Alarm -Service Coverage is Selected Area 151 - Smoke Detectors : 0 Ionization 151 - Photoelectric 10 -Duct Smoke Detectors: Or4onization 10 - Photoelectric 26 - Heat Detectors: 0 - ROR (Rate of temperature rise) 0 -Fixed Temperature 26 - Combination Manual Fire Alarm and Guard's Tour Supervisory Service 21 - Manual Fire Alarm Boxes Alarm Notification and' Annunciation Devic �s 19 - Visual Signals Type'- Strobe 43-Audible/Visual Signals: Type - Strobe Control and Transmitter Unit Notifier ,400panel /7788RF Radio Dialer Remote Monitoring UL Listed Central Station File: S5087, Service Center Number: 2 LYDIA SECURITY MONITORI G+INC, DBA COPS MONITORING 6251 PARK OF COMMERCE BLVD BOCA RATON FL 33487-8232 Alarm Retransmission to Fire Department Private Communication System and Private Communication System Alarm Transmission Method: Radio Network/Transport (Two-way)