CC-18-3721Temporary Certificate of Completion Miami Shores Village 10050 N.E. 2nd Ave, Miami Shores, Florida 33138 Tel: 305-795-2204 Fax: 305-756-8972 Building Inspection Department This certificate issued pursuant to the requirements of the Florida Building Code 106.1.2 certifying that at the time of issuance this structure was in compliance with the various ordinances of the jurisdiction regulating building construction or use. For the following: Description: RENOVATIONS TO WEBER HALL Permit Type Building (Commercial) Bldg. Permit No. CC-12-18-3721 Owner BARRY UNIVERSITY INC Contractor MOSS & ASSOCIATES LLC Subdivision/Project Construction Type II-B Date Issued 12/18/2019 Occupancy R-2 / 628 Total Occupants Type Square Footage 45,466.00 Flood Zone X Location If the building is located in a special flood hazard area documentation of the as -built lowest floor 11300 NE 2ND AVE WEBER HALL elevation or lowest horizontal structural member has been provided and is retained in the records of Miami Shores, FL 33161 Miami Shores Village. This certificate issued pursuant to the requirements of the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the jurisdiction regulating building construction or use. 90 DAYS TCO EXCLUDING /P/ SECTION UNDER FIRE INSPECTION AND PENDING Building Officials Approval Ismael Naranjo, CBO APPROVED REVISIONS. Not Transferable POST IN A CONSPICUOUS PLACE Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 UNIFORM MUNICIPAL TCO/TCC INSPECTION REPORTING FORM Master Permit No. Miami -Dade County from Municipality: Municipal Permit No. (MBLD): ZMS —0492 Zc/ Job Address: I ta(DC) 1\\� , 7_t--w A -,j f 7 Unit: -B a ce- Project Name: t3ce-14pcc Qualifier's Name: -B&Z-rrVk-TY_A L1C_4:LA4 Qualifier's Phone: 9V4+4-093�� Email: Owner's Name: N Owner's Phone:%6 - Jq9 -_7�qq Email: Akt&Y -eflQ cam This Uniform Municipal TCO/TCC Inspection Reporting Form is used to gather trade approvals for Temporary Certificate of Occupancy (TCO) or Completion (TCC). Once validated by the Municipal Building Department personnel, the form must be present at the job site for the field inspectors. When all approvals have b en obtained, take the signed form back to the Municipal Building Department for TCO/TCC issuance. Form Validated by )m.-JR — Date: Bldg Dept Personnel: PrintName Signature 9 All "Required" TCO/TCC inspections indicated below must be signed "Approved" before certificate issuance Inspector's Approval Req'd. Trade Name ure Date Comments Building 1,,jC,,�, -qk7- 0 Electrical �11Q Fire L7 (2W0_r 1431944v_� I-W 6K,4e0Aybq 6kq6 dgu� 0 Mechanical 0 Plumbing 0 Public Works 0 Zoning 0 Other Important Note: The TCO/TCC is not valid and building and/or.space may not be occupied unless signed by the Building Official. Occupying the building and/or pace without obtaining a TCO/TCC issued by the Municipal Building Department is prohibited and is in violation of the Flori a Building Code Section 110.3. Building Official's Approval: Date: 11 1" TCO/TCC -ArExtension TCC/TCO Duration: '104, Conditions of TCO/TCC: 0 If Master Permit expires, the TCO/TCC will automatically be revoked and the space must be vacated. • A TCO/TCC may be revoked if any action by the contractor, owner or tenant creates any code violation affecting the proper occupancy of the area. • Any TCO/TCC that expires without renewal or has been revoked can result in a notice of violation, civil violation and/or disconnection of utility services. & Other conditions: 04/09D I.OSFBOA fib M -DADE COUNTY FIRE RESCUE IAMI OIL FIRE PREVENTION DIVISION TEMPORARY CERTIFICATE OF OCCUPANCY (T.C.0) A STATUS FORM Municipal Permit #: Miami -Dade Process # Miami -Dade Permit #: 2019049724 Owner/Contractors Name:Jorge Freyre Business Name: Barry Weber Hall Owner/Contractor Phone#: Contact Name: Jorge Freyre Phone # 786-299-7623 Address: 11300 NE 2 Ave Weber Hall city: Miami State: FL Zip Code: T.C.O. INFORMATION REASON Pending Plan Revision r7 Length: [030 Days P160 Days 90 Days Other (# of days) FIREWATCH Required: 11 Yes 7Z No RESTRICTIONS/ COMM E NTS (If Applicable) SUBSIDIARY PERMITS (Fire Alarm, Sprinkler, etc.) Fild I 4Aff HP T1Jc%PFrTT(1%JS All Life Safety completed NOTE: Submit this completed TCO Status form with a TCO Hardship letter (not applicable for municipalities), Fire Inspection Report, and a TCO Application from Miami -Dade County Building or Municipality Building Department to The Fire Prevention New Construction Bureau OIC or designee for approval. Lt. T. Carter 11-26-2019 Inspector's Signature 6v,:P. 1 L4 b:�o - OIC's Signature DATE If I r-Ij r;, D!ATE Rev 4-2014 Crook MIAMI-DADE FIRE RESCUE DEPARTMENT DATE FIRE INSPECTION REPORT CONTINUATION OCCUPANT lze- f 5,4y ADDRESS ff3 00 AIC �z A We bei'_ He-11 - . - 601 c_ I btb, x fro ue, Page of 12501-105 3/08 INSPECTOR Date: -Miami Shores Village - Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 Website: www.miamishoresvillaee.com TEMPORARY CERTIFICATE OF OCCUPANCY APPLICATION (T.C.0) Please be advised that the TCO expiration date Is based on conditions from Miami -Dade County Fire Dept. Folio#:11- 2WbDDI)CQ�70 Master Building Permit cc Miami -Dade Municipal Process#: M 2_01Y" 72W Contracting Company: 444 RA%ve/i2�. ac Owner/Tenant: Lot: Square Footage of Space:' Miami -Dade Municipal Permit#: Block: Subdivision: Street Address: li�011 /VF 21),(( Ave " 1"iVa"ol" Aae5. ;ci, -3Pbl Signature of applicant verifies the above information is true and correct. The Temporary Certificate of Occupancy Is issued to the above named for building at the above location only upon the express provisions that the applicant will be able by and comply with all conditions of the Zoning ordinances and all ordinances of Miami Shores Village and/or Florida Building Code pertaining to erection, construction or remodeling of buildings or structures. This also certifies that the electrical wiring and or equipment, and the plumbing work has been Inspected and approved. Al-ett 1_4_Af)9;04- Print Name of Applicant or Qualifier TCO Number: Expiration Date: Approved Use for Occupancy: Remarks Building Official/Designee: - — A n-m Signat4u*ro A=pplricant or Qualifier FOR OFFICE USE ONLY Fee: Technology Fee: Total: Inspections: Zoning Yes/No Plumbing Yes/No Building Yes/No Fire Sprinkler Yes/No Electrical Yes/No Fire Yes/No Mechanical Yes/No MC) August 6, 2019 Ismael Naranjo, Building Official Miami Shore Village Building Department 10050 NE 2nd Avenue, Miami Shore, Florida 33138 Re: Request for Temporary Certificate of Occupancy Miami Shores Village Permit # CC-12-18-3721 Business Name: Barry University Weber Hall Renovation Business Address: 11300 NE 2nd Avenue, Miami Shores, FL 33161 To Mr. Naranjo, Please accept this correspondence as a formal request for Temporary Certificate of Occupancy of the above referenced job previously inspected and approved for TCO by Miami Shores Village Building Department, on This request is for commencement of regular business at Barry University Weber Hall. The TCO is being requested due to the further investigation needed to obtain the municipal water supply results, in order to determine whether the water pressure is insufficient for the design of a fire sprinkler system without installation of a fire pump, which would constitute an exemption to the fire sprinkler requirements set forth in Florida Building Code. We are requesting 90 days for the TCO, and within this time, every attempt will be made to obtain the Final CO. If the Final CO is not obtained, a Request for TCO Extension will be obtained. During this time, all means of egress shall be kept clear and accessible and all life safety systems will be maintained and kept operable at all times while the building is being occupied. Moss & Associates, LLC hereby will hold harmless and release Miami Shores Village Building Department and Miami Dade Fire Department from any liability that may arise during the use of designated areas in the afore mentioned facility while under the limitation of the Temporary Certificate of Occupancy. if you have any questions or need additional information, please feel free to contact the project manager Mike Cottle at (954)205-6670. Sincerely, r_rettAtkinson Executive Vice President/Project Executive -STATE OF FLORIDA COUNTY OF40+AM"*0E'?l R-P wA oeb On this dayof 2019, the undersigned authority personally appeared BRETT LAMMSONwho, after being duly sworn and deposed, upon oath, executed Certification and acknowledge the contents thereof to be true and to be used for the purposes mentioned. NOTARY PUBLIC (seal) 2937 SW 27th Ave PHONE 954.S24-5678 Ste. 203 FAX 954.524.5677 Coconut Grove, I'L 33133 WEB SITE WWW.MOSSCM.COM "P ,toing "Uh". I -)D Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 UNIFORM MUNICIPAL TCO/TCC INSPECTION REPORTING FORM Master Permit No. Miami -Dade County from Municipality: Municipal Permit No. (MBLD) r-1- ��/ 61 Job Address: 1'00t, IVC— 21,d Ale, Alv?nni 51WMnit: Project Name: j8y I Qualifier's Nam ' e: biytt *�Uq on Qualifier's Phone: Email: Owner's Name: _5�45,U Ae50&hcd_ Owner's Phone: Email: This Uniform Municipal TCO/TCC Inspection Reporting Form is used to gather trade approvals for Temporary Certificate of Occupancy (TCO) or Completion (TCC). Once validated by the Municipal Building Department personnel, the form must be present at the job site for the field inspectors. When all approvals have been obtained, take the signed form back to the Municipal Building Department for TCO/TCC issuance. Form Validated by 15Me4dt O��TD c:::: Date: Bldg Dept Personnel: Print Name U Signature 0 All " equired" TCO/TCC inspec ions indicated below must be signed "Approved" before certificate issuance 1 nector's A rn%nd Req'd. Trade ame pp Signature ate] Comments Building k97 / IV -A Electrical GOSA Fire (Mawir I �� k, 7-CO. Ok- q0c6qj F1 7� mechanical Plumbing rj,04,1 11 Public Works 11 Zoning 0 1 Other Important Note: The TCO/TCC is not valid and building and/or space may not be occupied unless signed by the Building Official. Occupying the building and/or space without obtaining a TCO/TCC issued by the Municipal Building Department is prohibited and is in violation of th Building Code Section 110.3. Buildiog Official's Approval: Date: X'� e TCO/TCC 11 Extension TCC/TCO Duratio Conditions of TCO/TCC: • If Master Permit expires, the TCO/TCC will automatically be revoked and the space must be vacated. • A TCO/TCC may be revoked if any action by the contractor, owner or tenant creates any code violation affecting the proper occupancy of the area. • Any TCO/TCC that expires without renewal or has been revoked can result in a notice of violation, civil violation and/or disconnection of utility services.,j • Other conditions: Jr j - 04/09D I.OSFBOA FIRESTOPPING AFFID"IT We certify that the fire rated walls installed at Barry University- Weber hall have been firestopped at the top and bottom against the passage of hot flame and gases with a material capable of maintaining the fire resistance of the fire barrier, or protected by an approved system or device designed to provide such protection which has been tested in accordance with ASTM E814 or UL 1479. We further certify that our company has been trained by the manufacturer (Hilti) and we are qualified to install their products. We make no greater warranty claims the that of the material manufacturer. Date :z 30 � I Bob Gordon Project Manager SWORN TO AND SUBSCRIBED before me Bob Gordon who is personally known to me, and who did take an oath, this 30 day of J ly 2019. Signature of Notary Printed Name of No ry Commission No. log Commission Expiration SEAL: Fl. LINDSAY LARSEN Notant Public State of Florida Com mission # GG 103748 M Comm. Expires Apr 4, 2023 OF ded through National Notary Assn CERTIFICATION OF INSULATION INSTALLATION JOB NAME: Weber Hall -Barry University BUILDING PERMIT #: JOB ADDRESS: 11300 NE 2"' Ave Miami Shores, FL 33161 STATEMENT OF COMPLIANCE: We the undersigned hereby certify that the thermal insulation has been installed in the referenced building in compliance with the South Florida Building Code, and the Florida Model Energy Code, and the approved plans and specifications, and in accordance with good construction practice. The insulation furnished is of the type, thickness, and R value as set forth below: EXTERIOR WALL INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: CEILING/ROOF INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: STUD WALL INSULATION: Manufacturer: —Certainteed Type: Kraft Thickness: 1011 R-Value: 30 Sq. Ft. Used: 13,816 Installed by: Lotspeich Co. of Florida, Inc. (Company Name) (Licensed tontractor's Signature) Date: 7/23/19 Insulation Contractor CC# CGC1507337 CERTIFICATION OF INSULATION INSTALLATION JOB NAME: Weber Hall -Barry University BUILDING PERMIT #: JOB ADDRESS: 11300 NE 2,d Ave Miami Shores, FL 33161 STATEMENT OF COMPLIANCE: We the undersigned hereby certify that the thermal insulation has been installed in the referenced building in compliance with the South Florida Building Code, and the Florida Model Energy Code, and the approved plans and specifications, and in accordance with good construction practice. The insulation furnished is of the type, thickness, and R value as set forth below: EXTERIOR WALL INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: CEILING/ROOF INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: Installed by: Lotspeich Co. of Florida, Inc. (Company Name) Date: 7/23/19 STUD WALL INSULATION: Manufacturer: -Certainteed Type: Unfaced Thickness: 3 1/2 R-Value: 11 Sq. Ft. Used: 682.52 nAj,L�� (Licensed toNtractoir�s Signature) Insulation Contractor CC# CGC1507337 CERTIFICATION OF INSULATION INSTALLATION JOB NAME: Weber Hall -Barry University BUILDING PERMIT #: JOB ADDRESS: 11300 NE 2"d Ave Miami Shores, FL 33161 STATEMENT OF COMPLIANCE: We the undersigned hereby certify that the thermal insulation has been installed in the referenced building in compliance with the South Florida Building Code, and the Florida Model Energy Code, and the approved plans and specifications, and in accordance with good construction practice. The insulation fumished is of the type, thickness, and R value as set forth below: EXTERIOR WALL INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: CEILING/ROOF INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: STUD WALL INSULATION: Manufacturer: Certainteed Type: Unfaced Thickness: 6 1/2" R-Value: 19 Sq. Ft. Used: 384 Installed by: Lotspeich Co. of Florida, Inc. /I �� I , (Company Name) (Licensed C�ntracto-r'-!;Whature) Date: 7/23/19 Insulation Contractor CC # CGC1507337 J z/ L RiD JOHNSON, LEVINSON, RAGAN, DAVILA, INC. CONSULTING ENGINEERS 1450 Centrepark Boulevard, Suite 350 West Palm Beach, FL 33401 (561) 689,2303' (561) 689-2302 Fax www.jlTdinc.com August 14, 2019 Moss Construction 2101 N. Andrews Ave. Wilton Manors, FL 33311 Re: Barry University — Weber Hall Fire Pump JLRDProjectNo. 118028 To Whom It May Concern: JLRD is in receipt of the water pressure report dated August 8, 2019 taken by Marlin Plumbing of Miami with a pressure of 38 PSI under full load. Based on the test provided, it is JLRD's opinion there is insufficient municipal water pressure at the building to support an automatic sprinkler system without the use of a fire pump. Should you have any questions, pteU6';01jW'&,� p discuss. Sincerely, 0 V Cc 0�- Michael P. Linden, P.E. -Z Vice President PLO MPL/ar t'�s 10 ""' "'lij.111111 G: �] 18028 Barry University Weber Hall Ren i ns etterslBarty University Weber Hall Fire Pump 08-12-19.docx IFIRESTOPPING AFFID"IT We certify that the fire rated walls installed at Barry University- Weber hall have been firestopped at the top and bottom against the passage of hot flame and gases with a material capable of maintaining the fire resistance of the fire barrier, or protected by an approved system or device designed to provide such protection which has been tested in accordance with ASTM E814 or UL 1479. We further certify that our company has been trained by the manufacturer (Hilti) and we are qualified to install their products. We make no greater warranty claims then that of the material manufacturer. Date--7 30 q Bob Gordon Project Manager SWORN TO AND SUBSCRIBED before me Bob Gordon who is personally known to me, and who did take an oath, this 30 day of July 2019 Signature of Notary�� MPJ Printed Name of No�� DQ20q �ka(61 Commission No. Commission Expiration SEAL: .'�'k,Ay P41, LINDSAY LARSEN Florida Notary Public - State of Commission # GG 303748 My Comm. Expires Apr 4, 2023 Bonded through National Notary Assn, 0 CERTIFICATION OF INSULATION INSTALLATION JOB NAME: Weber Hall -Barry University BUILDING PERMIT #: JOB ADDRESS: 11300 NE 2nd Ave Miami Shores, FL 33161 STATEMENT OF COMPLIANCE: We the undersigned hereby certify that the thermal insulation has been installed in the referenced building in compliance with the South Florida Building Code, and the Florida Model Energy Code, and the approved plans and specifications, and in accordance with good construction practice. The insulation filmished is of the type, thickness, and R value as set forth below: EXTERIOR WALL INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: CEILING/ROOF INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: Installed by: Lotspeich Co. of Florida, Inc. (Company Name) Date: 7/23/19 STUD WALL INSULATION: Manufacturer: —Certainteed Type: Kraft Thickness: 1011 R-Value: 30 Sq. Ft. Used: 13,816 CA L (Licensed Contractor's Signature) Insulation Contractor CC# CGC1507337 CERTIFICATION OF INSULATION INSTALLATION JOB NAME: Weber Hall -Barry University BUILDING PERMIT #: JOB ADDRESS: 11300 NE 2nd Ave Miami Shores, FL 33161 STATEMENT OF COMPLIANCE: We the undersigned hereby certify that the thermal insulation has been installed in the referenced building in compliance with the South Florida Building Code, and the Florida Model Energy Code, and the approved plans and specifications, and in accordance with good construction practice. The insulation furnished is of the type, thickness, and R value as set forth below: EXTERIOR WALL INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: CEILING/ROOF INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: Installed by: Lotspeich Co. of Florida, Inc. (Company Name) Date: 7/23/19 STUD WALL INSULATION: Manufacturer: —Certainteed Type: Unfaced Thickness: 3 1/2 R-Value: I I Sq. Ft. Used: 682.52 (Li&ensed- Contractor"sSignature) Insulation Contractor CC# CGC1507337 CERTIFICATION OF INSULATION INSTALLATION JOB NAME: Weber Hall -Barry University BUILDING PERMIT #: JOB ADDRESS: 11300 NE 2,d Ave Miami Shores, FL 33161 STATEMENT OF COMPLIANCE: We the undersigned hereby certify that the thermal insulation has been installed in the referenced building in compliance with the South Florida Building Code, and the Florida Model Energy Code, and the approved plans and specifications, and in accordance with good construction practice. The insulation furnished is of the type, thickness, and R value as set forth below: EXTERIOR WALL INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: CEILING/ROOF INSULATION: Manufacturer: Type: Thickness: R-Value: Sq. Ft. Used: Installed by: Lotspeich Co. of Florida, Inc. (Company Name) Date: 7/23/19 STUD WALL INSULATION: Manufacturer: Certainteed Type: Unfaced Thickness: 6 1/2" R-Value: 19 Sq. Ft. Used: 384 ____ AA,/L, (Liczsed'Contractor's Signature) Insulation Contractor CC# CGC1507337 J'10010 L RiD JOHNSON, LEVINSON, RAGAN, DAVILA, INC. CONSULTING ENGINEERS 1450 CenuepaTk Boulevatd, Suite 350 West Palm Beach, FL 33401 (561) 689-2303 * (561) 689�2302 Fax www.jlrdinc.com August 14, 2019 Moss Construction 2101 N. Andrews Ave. Wilton Manors, FL 33311 Re: Barry University — Weber Hall Fire Pump JLRDProjectNo. 118028 To Whom It May Concern: JLRD is in receipt of the water pressure report dated August 8, 2019 taken by Marlin Plumbing of Miami with a pressure of 38 PSI under full load. Based on the test provided, it is JLRD's opinion there is insufficient municipal water pressure at the building to support an automatic sprinkler system without the use of a fire pump. Should you have any questions, please contact me to discuss. Sincerely, Michael P. Linden, P.E. Vice President MPL/ar �Ao - O� 44' G: � 11802 8 Ba rry Un i vers i ty Web e r Hdt'%-*Q�� 'W�a rr -12-19.docx .. -% y University Weber Hall Fire Pump 08 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 UNIFORM MUNICIPAL TCO/TCC INSPECTION REPORTING FORM Master Permit No. Miami -Dade County from Municipality: &1p2_V- Municipal Permit No. (MBLD): FL ��Ibl Job Address: /1 ce IVC- 2vid IJW,, At4*_tZnJ 5AMnit: Project Name: �&y 4�6�� Qualifier's Name:.byytt Qualifier's Phone: Email: V — V Owner's Name: 5�42114 4_'&5Qm%40 Owner's Phone: Email: This Uniform Municipal TCO/TCC Inspection Reporting Form is used to gathertrade approvals for Temporary Certificate of Occupancy (TCO) or Completion (TCC). Once validated by the Municipal Building Department personnel, the form must be present at the job site for the field inspectors. When all approvals have been obtained, take the signed form back to the Municipal Building Department for TCO/TCC issuance. Form Validated by lsm4dt D a t e: k1l 61c rE Bldg Dept Personnel: Print Name Signature All equired" TCO/TCC inspections indicated below must be signed "Approved" before certificate issuance. Inspector's Approval Req'd. Trade Name Signature Date Comments _�S Building _'Y1 Electrical _-'U] Fire Mechanical Plumbing 0 Public Works 0 Zoning 0 Other Important Note: The TCO/TCC is not valid and building and/or space may not be occupied unless signed by the Building Official. Occupying the building and/or space without obtaining a TCO/TCC issued by the Municipal Building Department is prohibited and is in violation of the Florida Building Code Section 110.3. Building Official's Approval: 01 St TCO/TCC 0 Extension Conditions of TCO/`TCC: Date: TCCITCO Duration: • If Master Permit expires, the TCO/TCC will automatically be revoked and the space must be vacated. . • A TCO/TCC may be revoked if any action by the contractor, owner or tenant creates any code violation affecting the proper occupancy of the area. • Any TCO/TCC that expires without renewal or has been revoked can result in a notice of violation, civil violation and/or disconnection of utility services. • Other conditions: 04/09DI.OSFBOA Date Mhami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 Website: www.miamishoresvillage.com TEMPORARY CERTIFICATE OF OCCUPANCY APPLICATION (T.C.0) Please be advised that the TCO expiration date is based on conditions from Miami -Dade County Fire Dept. Folio#:11- 2-j3b'corocL�-r' Master Building Permit #: cc, — 1 12- -/S- - 372-1 Miami -Dade Municipal Process#: iti 2-01�6'172W Contracting Company: Owner/Tenant: 13ev-'m Square Footage of Space:* Miami -Dade Municipal Permit#: Lot: Block: Subdivision: Street Address: 1140t, /VF 2.-YA lhle �hqv5, t� 3�41 Signature of applicant verifies the above information is true and correct. The Temporary Certificate of Occupancy is issued to the above named for building at the above location only upon the express provisions that the applicant will be able by and comply with all conditions of the Zoning ordinances and all ordinances of Miami Shores Village and/or Florida Building Code pertaining to erection, construction or remodeling of buildings or structures. This also certifies that the electrical wiring and or equipment, and the plumbing work has been inspected and approved. IA'l?ltt ArA�i;04- Print Name of Applicant or Qualifier TCO Number: Expiration Date: Approved Use for Occupancy: Remarks: Building Official/Designee: A Signa4tureo 7ppiricant or Qualifier FOR OFFICE USE ONLY Fee: Technology Fee: Total: Inspections: Zoning Yes/No Plumbing Yes/No Building Yes/No Fire Sprinkler Yes/No Electrical Yes/No Fire Yes/No Mechanical Yes/No MC) August 6, 2019 Ismael Naranjo, Building Official Miami Shore Village Building Department 10050 NE 2 nd Avenue, Miami Shore, Florida 33138 Re: Request for Temporary Certificate of Occupancy Miami Shores Village Permit # CC-12-18-3721 Business Name: Barry University Weber Hall Renovation Business Address: 11300 NE 2 id Avenue, Miami Shores, FL 33161 To Mr. Naranjo, Please accept this correspondence as a formal request for Temporary Certificate of Occupancy of the above referenced job previously inspected and approved for TCO by Miami Shores Village Building Department, on This request is for commencement of regular business at Barry University Weber Hall. The TCO is being requested due to the further investigation needed to obtain the municipal water supply results, in order to determine whether the water pressure is insufficient for the design of a fire sprinkler system without installation of a fire pump, which would constitute an exemption to the fire sprinkler requirements set forth in Florida Building Code. We are requesting 90 days for the TCO, and within this time, every attempt will be made to obtain the Final CO. If the Final CO is not obtained, a Request for TCO Extension will beobtained. During this time, all means of egress shall be kept clear and accessible and all life safety systems will be maintained and kept operable at all times while the building is being occupied. Moss & Associates, LLC hereby will hold harmless and release Miami Shores Village Building Department and Miami Dade Fire Department from any liability that may arise during the use of designated areas in the afore mentioned facility while under the limitation of the Temporary Certificate of Occupancy. if you have any questions or need additional information, please feel free to contact the project manager Mike Cottle at (954)205-6670. Sincerely, —r e rtt n ,.e e President/Project Executive STATE OF FLORIDA COUNTY OFA*Ah"-e*M BRowAR-D On this (0 —day of aIC5���-2019, the undersigned authority personally appeared b me, 0 BRETTT*A1=S0Nwho, after being duly sworn and deposed, upon oath, executedth Certification and acknowledge the contents thereof to be true and to be used for the purposes tl mentioned. NOTARY PUBLIC (seal) 2937 SW 27th Ave PHONE 954.524.5678 Ste. 203 FAX 954.524.5677 Coconut Grove, FL 33133 WEB SrFE WWW.MOSSCM.COM /Z *&M! ssir R 7 toing . .. ....... J L R D JOHNSON, LEVINSON, RAGAN, DNVILA, INC. CONSLILTINC ENGINEERS 1450 Cenuejwk Bouleva4 Suite 350 West Palm Beach, FL 33401 (561) 689,2303 - (561) 689-2302 Fix www.jhdinc.com August 14, 2019 Moss Construction 2101 N. Andrews Ave. Wilton Manors, FL 33311 Re: Barry University — Weber Hall Fire Pump JLRDProjectNo. 118028 To Whom It May Concern: JLRD is in receipt of the water pressure report dated August 8, 2019 taken by Marlin Plumbing of Miami with a pressure of 38 PSI under full load. Based on the test provided, it is JLRD's opinion there is insufficient municipal water pressure at the building to support an automatic sprinkler system without the use of a fire pump. Should you have any questk ,paRopase,co,Ttact me to discuss. Sincerely, % 1. 4 Michael P. Lindetitmk O�-- Cc' %, *. '.5 Vice President MPUar O'C' 10 G:U18028 Barry University Wei;�illHat4lfte"6�ations�LetteiwlBariy University Weber Hall Fire Pump 08-12-19.docx -P -to tc--� up -Q) U-UVD L-C-- �10- ool��S- r-,Lk -Fnacs -��6 1 (:�-D � Nj (� R D J(-.)HNSON, LEVINSON, I�AGAN, D,-WILA, INC. CONSULTING ENGINEERS 1450 Centmpark Boulevard, Suite 350 West Palm Beach, FL 33401 (561) 689-2303 " (561) 689-2302 Fax www.JlTdinc.com August 14, 2019 Moss Construction 2101 N. Andrews Ave. Wilton Manors, FL 33311 Re: Barry University — Weber Hall Fire Pump JLRDProjectNo. 118028 To Whom It May Concern: JLRD is in receipt of the water pressure report dated August 8, 2019 taken by Marlin Plumbing of Miami with a pressure of 38 PSI under full load. Based on the test provided, it is JLRD's opinion there is insufficient municipal water pressure at the building to support an automatic sprinkler system without the use of a fire pump. Should you have any queq PsA*ase.cont; $"-. V^ Sincerely, 140. Cc Michael P. Linde&, &K Qj Vice President PL 0 g\V. MPI-Jar me to discuss. G:1118028 Barry University WeRF,*HaMR&Wi;alions�LettersIBarry University Weber Hall Fire Pump 08-12-19.docx R D JOHNSON, LEVINSON, I�AGAN, DAVILA, INC. CONSULTING ENGINEERS 1450 CentrepaTk Boulevard, Sulte 350 West Palm Beach, FL 33401 (561) 689,2303 * (561) 689-2302 Fax wwwjlrdimcom August 12, 2019 Moss Construction 2 101 N. Andrews Ave. Wilton Manors, FL 33311 Re: Barry University — Weber Hall Fire Pump JLRD Project No. 118028 To Whom It May Concern: JLRD is in receipt of the water pressure report for the existing water line proposed to serve as the fire protection for the renovations. The date of the report is August 8, 2019 taken by Marlin Plumbing of Miami with a pressure of 38 PSI under full load. Based on these conditions, JLRD would recommend the use of a fire pump to assure the life safety aspect of the fire protection system could be maintained at all times. Currently, JLRD could not advise the Owner the measured pressure would suffice. Should you have any questions, please Sincerely, Michael P. Linden, P.E. Vice President MPL/ar L N0.58094 STATE OF CIA% G:11 18028 Barry Unimrsity Weber Hall ReirovationsletterslBarry Universi(v Weber Hall Fire Pump 08-12-19.docx CANNONDESIGN August 05, 2019 Ismael Naranjo Building Director Miami Shores Village 10050 NE 2 Ave Miami Shores, Florida, 33138 Re: Barry University — Weber Hall Renovation Permit #CC-12-18-3721: Code Conformance Statement Dear Mr. Naranjo: Per your request, refer to the below statement: It is of CannonDesign's opinion that the plans and amended construction documents for the project conform to the technical codes, the laws of egress, type of construction and general arrangement. We thank you for your consideration on this matter. Sincerely, Roland Lemke, AIA, LEED AP Principal 1560 WILSON BOULEVARD, SUITE 200, ARLINGTON, VIRGINIA 22209 J J RiD JOHNSON, LEVINSON, RAGAN, DAVILA, INC. CONSULTING ENGINEERS 1450 CentrepaTk Boulevard, Suite 350 West Palm Beach, FL 33401 (561) 689-2303' (561) 689-2302 Fax www.jlrdinc.com August 7, 2019 Mr. Ismael Naranjo, BO Miami Shores Village 10050 NE 2 Ave Miami Shores, FL 33138 Re: Barry University — Weber Hall Renovation JLRDProjectNo. 118028 Dear Ismael, This letter pertains to the inspector's request for confirmation of compliance with 2017 FBC Building - 907.4, 907.5, and 907.6. JLRD has reviewed the referenced code sections listed above for this project's Group type, R-2. Specifically, section 907.2.9 Group R-2, is the relevant code section for this project and lists the specific requirements contained within the general requirements of 907.4 through 907.6. Based on these requirements and the project's specific scope for the existing fire alarm system, the design intent of construction documents for an automatic smoke detection design and occupant notification is, to the best of our knowledge, incompliance with the applicable codes for this group type. This position is further supported by the building plan approvals provided by both Miami Shores Village and Miami -Dade. If you have any questions or require additional information, please contact our office. Sincerely, JOHNSON, LEVINSON, RAGAN, DAVILA, INC. Charles C. Gableman, P.E., LEED APO President CCG/bev %W11W111011j" top 0# ­E No. 51936 0 STATE OF <el A t G:U18028 Barry University Weber Hall Renovations IettersTire Alarm System -Inspector Letter 08-07-19.docx