WS-19-877Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Permit NO.: WS-(-19-877
Permit Type: Windows/Shutters
IWdrk,£9assificatioa: Window/moor Replacement
Permit Status: Approved
Issue Date:05/01/2019 Ex iration: 10/28/2019
Location Address Parcel Number
863 NE 92ND ST, Miami Shores, FL 33138 1132060050040
Contacts
ROXINE GORDON Owner FHIA LLC Contractor
863 NE 92 ST, MIAMI SHORES, FL 331382908 WAYNE BURNETT
Business:9547924415210 PERMITS@FHAPRODUCTS.COM
Inspection
Description: REPLACE 12 WINDOWS W/ IMPACT SIZE FOR SIZE Valuation: $ 22,667.00 Requests:
r-762-49—AQ
Total Sq Feet: 0.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$13.80
DBPR Fee
$3.30
DCA Fee
$2.20
Education Surcharge
$4.60
Scanning Fee
$9.00
Technology Fee
$5.50
Windows/Shutters Fee
$170.00
Total:
$258.40
Payments
Date Paid Amt Paid
Total Fees
$258.40
Credit Card
04/22/2019 $50.00
Credit Card
05/01/2019 $208.40
Amount Due:
$0.00
Building Department Copy
In consideration of the issuance to 1he of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in st ct co ormity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting thisr it I asume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for E R L, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVR
regulating construction
xegoing information is accurate and that all work will be done in compliance with all applicable laws
, 1 authorize the above named contractor to do the work stated.
Authorized Signature: Owner
/ Applicant / Contractor / Agent
Date
May 01, 2019 Page 2 of 2
BUILDING
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
M.
CE�v�D
APR 2 201
FBC 201)-
Master Permit No. v ^`� ,(
3 `� — l I —88 7
PERMIT APPLICATION Sub Permit No.
BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 9(z �JE g a S �
City: Miami Shores County: Miami Dade Zip: 33 13 R
Folio/Parcel#:_ 0 0 C)- 00w) Is the Building Historically Designated: Yes NO 7�
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): F-0x1 N E GO91QO 9j Phone#: 7�6" 338 -Oa07
Address: 063 WE; Al S t
City: 1M1 R IMF S (-i 0 K G-S State: rz- Zip: 33 13 S /'
Tenant/Lessee Name: Phone#: 5q ' 7Ra -T41`�
Email:
CONTRACTOR: Company Name: L C Phone#: Q5+7Q) -91lb
Address: 3444 30 4Z 5-- \�okL_l IDO
City: ,)U` LA J`W "i C4- NPJ 0 -I
Qualifier Name: lQ1NE + b�PrN
FL zip: 333 UL
ne#:
State Certification or Registration #: CGIC06 l Sto Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ Q_ 1 COG I Q 0 Square/Linear Footage of Work: (a0 SQ Ir .
Type of Work: ❑ Addition
y„❑ Alteration El New Yf Repair/Replace El Demolition
Description of Work: Q P I n CE k � w 1 wo (.o W � lM A lA cy 9 \ ?'.i frM S (G� -
Specify color of color thru tile:
Submittal Fee $� 1d Permit Fee $
Scanning Fee $
Radon Fee $
Technology Fee $ Training/Education Fee $
Structural Reviews $
CCF $
DBPR $
CO/CC $
Notary $
Double Fee $
Bond $
(Revised02/24/2014)
TOTAL FEE NOW DUE $
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zi
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
kvl
Signature Signatur
4
OWNER or AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
day of d l 20 1 1 by day of 20 /f by
T 5=1n• who is i �� �- ��ho is rsonaJ < n to
me or who has produced as me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Sign:,o
��
Print:
/mot cr4
ABDIELR.CASTILLO
;?o':
MY COMMISSION # GG 07MEXPIRES:
JPrinSeal:
March 6 2021
Bmded Thru Notary Pubk Underwnters
APPROVED BY
1 _ p ��
Plans Examiner
Structural Review
ZIA ai
M!"EL A MERICADO
MY COMMISSION # GG095745
EXPIRES Ap0119, 2021
###################################
Zoning
Clerk
(Revised02/24/2014)
"J � 0LA- \0\- 3 �A "�-
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Inspection requirements for: 1.
Windows, Doors, Skylights or Fixed Glass (cladding) Permits
Upon issuance of permits for the scope of work involving the removal, changing and/or
replacement of any type of windows, doors, sidelites, skylights or fixed glass (cladding)
the permit holder or qualifier bearing his signature on the permit application shall abide
by the requirements of this department and comply with the following statement:
Upon obtaining window and/or door permits for the installation of same, it is the
responsibility of the permit holder to -request window/door framing in -progress
inspection, prior to concealment of any horizontal or vertical clip mullion, bucks, shims,
etc. Inspector will also verify anchor type, edge distance, embedment and spacing. The
purpose for this inspection, is for the verification of conformance with Product
Approval (NOA).
A 1 gement:
NIIm
Quali er/Owner Signature Date
Print Name
Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
REPLACEMENT OF WINDOWS, DOORS AND SHUTTERS.
Permit application must be accompanied by:
❑ Two (2) copies of drawing of the building, showing location of the windows, doors and
shutters to be replaces.
❑ Two (2) copies of the Comparison Chart, with all the required information. (NOA approval
number, size of each opening, (width and height), opening design pressures, and design
pressures for each component taken from the individual NOA, "Notice of Acceptance")
❑ Two (2) copies of State of Florida or Miami Dade County approved NOA for each different
components being installed. (Windows, Doors, Mullions, Fixed Glass, shutter)
❑ Florida Building Code -Existing Building, section 706.4 Replacement of windows and
doors. The replacement of garage doors, exterior doors, skylight, operative and inoperative
windows shall be designed and constructed to comply with Chapter 16 of the Florida
Building Code, Building.
Exceptions:
2. Opening protection exception for High -Velocity Hurricane Zones. For one -and
two-family dwellings constructed under codes prior to September 1, 1994, the
replacement of exterior doors with glazing, sliding glass doors, glass patio
doors, skylights, and operable and inoperable windows within any 12- month
period shall not be required to have opening protection provided the aggregate
area of the glazing in the replaced components does not exceed 25 percent of the
aggregate area of the glazed openings in the dwelling or dwelling unit.
i
❑ Every bedroom shall have at least 1 egress opening. The minimum opening size: (20" wide x
24" high)
❑ If Owner is doing the work, include the Owner Builder Disclosure.
❑ Require inspections: Buck (if greater than Ix), Framing and Final.
THE ABOVE REQUIREMENTS ARE FOR EXACT RETRO-FIT ONLY. WINDOWS, DOORS AND
SHUTTERS MUST BE INSTALLED AS PER PRODUCT APPROVAL. GROUT OR HYDRAULIC CEMENT
ARE NOT ALLOWED AS INFILL ON THE PERIMETER OF THE WINDOWS OR DOORS UNLESS
SPECIFIED ON THE PRODUCT APPROVAL.
Revised on 7/22/2009;11/17/2014
""'do Moms Improvement Associates
Ucenve No. CGC 061M / QB4MB
Broward Tel, 934-792-4415
3044 Sw 42' St_ FL iaudeidale. Fl 33312
Miami Dade- 305-SASW9
FLORIDA
fax 254-792-2170
N014E
Web- www.fhaproducts.com
1
SSOCIATU ✓
Emag:infoAofhaproductscoin
Home Improvement Contract
r
o,atff
Owner bC. r.s-_._-�i:rLti�f .._� H.Ph: �(Tj 31je� -1�� j�l
�r
Alt Ph_ 7"do
\'IV
A
V \\
Co Owner. ` _ Small. �C f'('j?C CC
L•'r w( Lint '►
1
-C7 tilt �t Cnta j
~`
t,�
vAddress City County
State Zip
{
this Contract is made and entered into this dsy of ____. .___,20_ by and between Faorlde Home Improvement Associates, Inc, a
Florida Corporation known as ('Contractoira "F W), owners)
\�
and named above of the property located
('Owner')_ The Contractor sprees to perform the work described below at the property listed above:0.
at the address listed above known as
i) Remove exiting units to be replacod iNoie: Removed meals are likely to be d1maged4
2) Prepare Openg!w6cessarvtoWaivereplacementwas
d) window vinylEnergy Storm Saver _ Alunanuminsubted _ ,�AlumbnumNon-ImAimed
.+aer•+..+r.sa.sy.r
a .r .�r.�.
Al OOdrs VMit4Energy, Storm Smr .._..._ Alumkniminsubred .__�_AlummtrmNon-(mutated
�"�r'�"rie
Glass: a --\ act (I Non -Impact ) Frame Color: White; _ BrOnte. _ B/W Tan; _Grey. _ PANE ,
yes( )Not I W__ Qty:` Qty Qtyi— Qty _ AFA
standard
custom Activevvee !!! FA fn RH � City:1/4-1/2-1/4
1/3-1/3-Us
SRdbtg Glass floor Single French )g fllDdL _ Geometric Qtr. _
AAAF FA FAAF Door Qtyt _ Doaa. gtyr_
�'y_ Qty�_ I Icttr.— Wye ,RH ( 1 IN ( ) RA { } la ( }
5) Work to be completed as stated on the eoconnptnyirig srorksheet Work NOT to he conpleted•
.� --- -- blRist filtY: •—..—
Cla oup liw if" and provide necemry permits and Insio ice. if applic"; In the event that Contractor 1s undb fdr whetever nrsson to otnain propei
pera is prior to c"intmove tent of any work, ComfKwr shag refund any previous payment and this transaction "be automatically amfled
Add"` Vllo No w at to aR�gq� rs to be done u �
Warranty, Contractor wilt! provloa warranty irdormado �Atner within 30 days after completion and final payment.
;btor shsR
;byte- Contractor commence th rk within � days after execution of the Contract (The'Commencement Date) and shag endeavor
to complete all work hereunder within days after the Commencement Date-
U By selecting the finance option for the partial or hull payment of this protect. The Owner agrees to sign all finance completion forms the final day
of installation The scheduling and completion of the final inspection wag be scheduled for the next available day and AU checklist rrems, pain,
replacement or damaged product reorders will be completed Ina timely manner as part of our service policy, kdtial flan
Nona to the owner, R ffaerWng n being obta ed by Owner
a) Do not standtlsContrad or arty financing dowment in bbnk. You are aidtkd to a OM of the centraet at tha time van sign.
b) The flitandal documnes provided by the lender W thb hang knpmwwwd antral may creota a Ike on Vwr property.
G me sun your understand all provisions of tho Contract and financial documents before you swi.
TOTAL PRICE S Deposit to Order: S .00
Sales tax: S_ � ' lQr� -_� Payment Day Job Starts00
S
rotal Project S_ ate" Installation Completion:
lasce"OnIm This Contract and the accompanying worksheet contain the entire agreement between the parties. By sigrNngthis COntraiM Owner
agrees and acknowledges that it has received the accompanying worksheet This Contract may not be changed orally but only by a Change Order or
other writtan amendment sl;ned by both parties. The waiver by any party of a breach of any provbons Of this Contract shag not operate or be
construed ass waiver of any written amendment or wakrer of any subsequent b marh by am owty. You the buyer may ancel this contract at any
time prior to midnight on the third business day after the data of this Conb*d
in witness whereof, the parties hereto have read, understand and agree to both sides of" Contract. Se the a exphado el contrato an su totalidad
y entknido todas las condbciones de este contrato Both parties execute this Contract and the owner(sl agree the ba due under this
Contact under sear as of the day nit year first above written.
/7a Y~
oavnarpriM` Cc -Owner Print ContradorJteprsde Print
Ownersbgnaturs Co-owner Signature cOmradorRep enlativisignature
HOME OWNERASSDN. Name. Phone:
YES ( ) NO ( Property Name:
Property Search Application - Miami -Dade County Page 1 of 1
14:-71
;1�� # OFFICE OF THE PROPERTY APPRAISER
Summary Report
Property Information
Folio:
11-3206-005-0040
Property Address:
863 NE 92 ST
Miami Shores, FL 33138-2908
Owner
ROXINE K GORDON
Mailing Address
863 NE 92 ST
MIAMI SHORES, FL 33138-2908
PA Primary Zone
0900 SG FAMILY - 1901-2100 SQ
Primary Land Use
0101 RESIDENTIAL -SINGLE
FAMILY: 1 UNIT
Beds / Baths / Half
3/2/0
Floors
1
Living Units
1
Actual Area
1,758 Sq.Ft
Living Area
1,410 Sq.Ft
Adjusted Area
1,584 Sq.Ft
Lot Size
9,653 Sq.Ft
Year Built
1954
Assessment Information
Year
2018
2017
2016
Land Value
$260,476
$260,476
$212,662
Building Value
$104,734
$104,734
$104,734
XF Value
$568
$576
$584
Market Value
$365,778
$365,786
$317,980
Assessed Value
$137,480
$134,653
$131,884
Benefits Information
Benefit
Type
2018
2017
2016
Save Our Homes
Assessment
$228,298
$231,133
$186,096
Cap
Reduction
Homestead
Exemption
$25,000
$25,000
$25,000
Second
Exemption
$25,000
$25,000
$25,000
Homestead
Widow
Exemption
1 $500
$500
$500
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
GOLDEN GATE PARK ADD PB 6-130
LOT 4 LESS E6.05FT & E1/2 LOT 5
BLK 1
LOT SIZE 68.950 X 140
OR 14550-664 0590 1
Generated On : 4/12/2019
Taxable Value Information
2018
2017
2016
County
Exemption Value
1 $50,500
$50,500
$50,500
Taxable Value
1 $86,980
$84,153
$81,384
School Board
Exemption Value
$25,500
$25,500
$25,500
Taxable Value
1 $111,980
$109,153
$106,384
City
Exemption Value
$50,500
$50,500
$50,500
Taxable Value
$86,980
$84,153
$81,384
Regional
Exemption Value
$50,500
$50,500
$50,500
Taxable Value
1 $86,9801
$84,153
$81,384
Sales Information
Previous Sale
Price
OR Book -Page
Qualification Description
05/01/1990
$90,000
14550-0664
Sales which are qualified
09/01/1979
$60,000
10522-2243
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer. asp
https://www8.miamidade.gov/Apps/PA/propertysearch/ 4/12/2019
{5�
P : = q h (GCp - GCp j)
V (mph)
175
1620 FBC l r HV HZ, or Fig. 26 5-la
Risk Cel gory
II
Tahlc 1.5-1, page
F..I—e•
C
Sanian 26.7
Kd
US
Table 26.6- I, page 25(1
KA
1
Figwc 26.8-I, page 252
GCp,
(118
.0.19 0.55
pnd, ol'nad
3112
14.0 degrees
meta
14.0degrees
Specialty Engineering Consuhants, Inc. E eta .4
1599 SW 30 Avenue, Suite *20
Boynton each, FL 334326 b
FL. CA It 009217
Wind Velocites in South Florida
Dade
Broward
Falm Bach
Risk CaL I
165
I56
156
L— risk to humans f , shuts
Risk Cat. 2
171
170
170
Single Faintly Res id—
Risk Cal. 3&4
186
Igo
Igo
ssrn
Edal Facilities
IJ}' X71 14.0 1 -11.4
No. 77012 : n'
,�p� STAT OF
ONAI-
'',11111111111111111
MAR 2 0 2019
863 NE 92 ST MIAMI SHORES FL 33138
IF
n
J
110-3/8 X 49-1/4
60) FL16736.2
ZONE 4
35-3/4 X 49-1/4
60) FL16736.1 FC Lam/
EGRESS ZONE4 C
PR 2 /�
110-3/8 X 61-3/4 110-3/8 X 49-1/4
35-3/4 X 49-1/4 (+/- 60) FL16736.2 (+/- 60) FL16736.2
(+/ 60) 736.1 `i `o BED '3 S ZONE 4 ZONE 4
ZONE 4
µs N EGRESS
i L -� 3
BATH 1 T-1
35-3/4 X 37-1/8
60) FL16736.1 \
ZONE 4 �
,a 5 KIT
35-3/4 X 37-1/8
60) FL16736.1 \
ZONE 4 y (�
NS
GARAGE
B."
36 X 49-1 /4
60) FL16736.1
DINING LSD ZONE
LIVING
0
PC
110-3/8 X 61-3/4
60) FL16736.2
ZONE 4
M ar,i SI—res Vidage �`
',PPr�OVFD BY DATE
Z-1 1tiG DEPT
M D a DEPT l� .
3-EJECT TO COMPLIANCE WI FH ALL FEDERAL
^ F AND C(_UP1'Y PALES AND R�:`;U�_ATIONS
BELL
BATH v
f�'S• • • •
•
r Wr
IIY
• • •
• 35-3/4 X 37.1 /8
�••••
6736.1
CjfJ�•
Z• 4 ••
•
•
•
S a
BEL? I
ll."
i
TO 1-1
......
U
..•.
35-3/4 X149-1/4
•
• •
—' •
(+/- 0) FL16736.1
•
i1 3c(2 3..
/EGRESS
�.
•
•.....
' '
•
110-3/8 X 49 1 /4
• • • •
(+/- 60) FL16736.2
ZONE 4
c�
4C3
1/4/2018
Florida Building Code Online
till
Y
BCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats @ Facts I Publications FBC Staff BCIS Site Map Unks Search
�,�+►
Product Approval
dFlorida
p
I USER: Public User
6..
Product Aooroval Menu > Product or Aoolication
Search > Aoolication List > Application Detail
FL *
FL16736-R2
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
D
Product Manufacturer
Custom Window Systems Inc.
Address/Phone/Email
1900 SW 44th Avenue
Ocala, FL 34474
(352)368-6922 Ext245
kpine@cws.cc
Authorized Signature
Kevin Pine
kpine@cws.cc
Technical Representative Jay Lathrop
Address/Phone/Email 1900 SW 44th Ave
Ocala, FL 34474
(352)368-6922 Ext291
jlathrop@cws.cc
Quality Assurance Representative Arturo Monteverde
Address/Phone/Email 1900 SW 44th Ave
Ocala, FL 34474
(352) 368-6922 Ext 221
amonteverde@cws.cc
Category Windows
Subcategory Horizontal Slider
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
U Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Lucas A. Turner
Evaluation Report
Florida License PE-58201
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 07/21/2020
Validated By Steven M. Urich, PE
• • • • • • • • • Validation Checklist - Hardcopy Received
• • • • • • • • •••
Certificate of Independence ••• ••; ••� • V173�•R2 COI EvalReoort871C.pdf
• • • ••
Referenced Standard and Year•(o&§landard) • ••• Standard
•
•• ; • • AfMA/VYDMA/CSA/101/I.S.2/A440-08
••� i• • �•• �•• AS E;886-05
• • • ASTO E41296-09
PA/TAS 201/202/203
Year
2008
2005
2009
1994
Equivalence of Product Standards ; • • • •
Certified By • • • • • • • • •
•
https://www.floddabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2flZmgTgPohLz6ontOd5HABPugYU IX1 zzFJrTCXA%3d%3d
1/2
1 /4/2018
Sections from the Code
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/28/2017
09/29/2017
10/03/2017
12/12/2017
FL #
Model, Number or Name
Description
16736.1
HS-8200 PVC Horizontal Slider
HS-8200 PVC Horizontal Slider, IMPACT, 74" x 63", XO or OX.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16736 R2 II CWS-871C.pdf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +60/-60
Evaluation Reports
Other: Large Missile, 74" x 63", DP +/- 60 psf. Outer lite in
FL16736 R2 AE EvalReoort871C.pdf
I.G. must be safety glazed when used above 30 ft. in HVHZ.
Created by Independent Third Party: Yes
Glass complies to ASTM E1300-04.
16736.2
i HS-8200 PVC Horizontal Slider
HS-8200 PVC Horizontal Slider, IMPACT, 111" x 63", XOX.
12
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16736 R2 II CWS-869C.pdf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +60/-60
Evaluation Reports
Other: Large Missile, 111" x 63", DP +/- 60 psf. Outer lite in
FL16736 R2 AE EvaIReport869C.Ddf
I.G. must be safety glazed when used above 30 ft. in HVHZ.
Created by Independent Third Party: Yes
Glass complies to ASTM E1300-04.
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Conyriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
M ag M Rh c
Credit Card
I Safe
•
• • ••• 0 •
https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDqu8obl%lflZmgTgPohLz6ontOd5HABPugYUIX1zzFJrTCXA%3d%3d
2/2
URNER
ENGINEERING &
CONSULTING, INC.
1239 Jabara Ave.
North Port, FL 34288
Ph. 941-3 80-1574
FBPE C.O.A. #29779
Evaluation Report 869C
September 7, 2017
Product Description: Series 8200 PVC Horizontal Slider Window, Large Missile Impact (HVHZ),
XOX I I I "x63" unit size with design pressures of +/-60 psf (Fin or Flange window)
Manufacturer: Custom Window Systems, Inc. 1900 SW 44th Ave, Ocala, FL 34474
Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC
Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 61h
Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product testing
standards performed are outlined below.
Technical Documentation:
1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL
2) Approval drawing CWS-869C, signed and sealed by Lucas A. Turner, P.E.
3) Test Reports NCTL-210-3887-3, -3A, -4, and 4A, by National Certified Testing Laboratories,
Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed: TAS 201, 202, 203
`94, ASTM E 1886 `02/04/05, ASTM E 1996 `04/06/09, and AAMA/WDMA/CSA
101/I.S.2/A440 `08
4) Supplemental Calculations to support CWS-869C, signed and sealed by Lucas A. Turner, P.E.
Installation: Units must be installed according to approval document CWS-869C.
Limitations of Use: This product:
• May be used up to the sizes and daylight openings indicated in CWS-869C
• Achieves design pressures of +/-60 psf
• Is Large Missile impact resistant and does not require the use of shutters
• May be used in the High Velocity Hurricane Zone
• In the operable sash, requires Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-
1117.021, and in the fixed glass requires Kuraray (Dupont) SentryGlas Interlayer per Miami -Dade
N.O.A. 14-0916.1 It
• Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 17-0206.1 Ot
t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find
that they comply with the requirements of the 6th Ed. (2017) Florida Building Code for use in this
product.
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial
interest in Custom Window Systems or in any company manufacturing or distributing products for which
this report is being issued.'r d6*&t:h4ve,•cwr:dd IAfend to acquire, nor will I acquire, a financial interest
in any other entity involved in the tes;ni ar a'* 0 process of this product.
• . •
.. ... ... ...
Lucas '
Turner ......
Al tab-i'tt
No 56201 :
.�••9; STATE OF0.
Ft
AZ
9/07/2017
Lucas A. Turner, P.E.
FL PE #58201
HORIZONTAL SLIDER - LARGE MISSILE IMPACT
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS ...........
1
GLAZING DETAILS.....................................
SECTION VIEWS &GLAZING DETAILS 3
....4
EXTRUSIONS & B.O.M...............................
ANCHOR SCHEDULE & NOTES................5
INSTALLATION DETAILS ...........................6
GENERAL NOTES:
CYlysL(Yom
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED
WINDOW
�]7d
SYSTEMS L�
TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT
EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND
1900 SW 44TH AVE.
1900 S4THFLORIDA E.
IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED
IN ASTM E 1996 PER THE FBC.
WWW CF34474
2. GLAZING OPTIONS: (SEE SHEET 2)
8200 PVC
3. CONFIGURATIONS:'OX', "XO".
HORZ, SLIDER
4. DESIGN PRESSURE RATING:
IMPACT
-NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND
GLASS TABLES ASTM E-1300-0401/09.
_j
-
-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER
INFILTRATION TEST PRESSURE AND GLASS TABLES
F
0 < w w O o
ASTM E-1300-04e01/09.
z
w _.j 0 a Z w
Q
O 3
w �
5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED
IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR
Z
F Lu Z}Z �
Z Z 2 ¢ w
DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD
O
w O O
O F O Q M F w
00
cj
Z Z Z
ANCHOR CALCULATIONS.
- U) � j
6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT
REQUIRED. THE IMPACT ROTARY
z
Q
>_
OOt=) 5U-
F- Z LL 2 ZOO LL Z
< 3 O H - � Z -
LOCKS ARE INTENDED TO BE LEFT
U rn
UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT, BUT
¢
w
OLL
MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE WINDS AND
o w o w - w
FLYING DEBRIS.
CL
Z = a - y
7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT
O
a
w0 (L2:
F w w 3 wa
ct
USED AT FIXED MEETING RAIL AND HEAD/SILL.
• •
������p10�REW
P
8. SERIES / MODEL DESIGNATION HS-8200. •
.�c .•.. • .,r4�•,
J�
9. THE DESIGNATION X AND O STAND FOR THE FOLLC.WINCS: •
•
• •:JG .' "kv -0-4 , G�
X = OPERABLE SASH, O = FIXED SASH • • ;
• !N; No 5829?
10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IR A ERMLAR
•
• •
• '. * • �• • • •
- : a
LOCATION. ••••••
-9
• 59STATE OF•; W
EXTERNAL W EEP SLOT = 1/4" 1" LOCATED 4' FROMrBOWW
•
O11. (4 R.
x ENDS.
• ��FS�. R 1 p
L•• •Yurne
•
•• ••••••
**:
�V.
ri
.
.
. ......
2017-05-22
; •
• • • 9/a2/2017 .
1 Uj444.00
;
• CUCAS A. TURNER!P.E.
•�••
FLPE#58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING
111" x 63" +/- 60 PSF I LARGE MISSILE IMPACT
GENERAL NOTES AND
ELEVATIONS
TEF I 10/11/13
CWS-869 C
'ALE: SHEET
1:20 1 OF 6
QUANEX DURASEAL
IG SPACER
7/8' OVERALL
3/16" ANNEALED OR TEMPERED
1/4' AIRSPACE
7/16" LAMI
3/16" ANNEALED
.090 SENTRY GLASS IONOPLAST INTERLAYER
3/16" ANNEALED
PURFECT GLAZE"H"
SIKAFLEX 552
1/2' GLASS BITE
GLASS GLASS TYPE A
FIXED
WINDOW SYSTEMS B
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8200 PVC
HORZ. SLIDER
IMPACT
7/8" OVERALL
1/8" ANNEALED OR TEMPERED
Q
Z 3 a Z 30
318" AIR SPACE
Z
W-1 p0 a Z w
5116"LAMI
0
~w3>-033=
LL
Z
1/8" ANNEALED
Z S m a W O O
.090 DUPONT PVB INTERLAYER
L)
Z N Z Z~ j y
118" ANNEALED
Q
O LL m ZO OO LL Z
>
Q
¢� W-=O-
ONO~Ztn
53:2W
O D y
QUANEX DURASEAL
IG SPACER
PURFECT GLAZE"H"
9 SIKAFLEX 552
W
a
IL a O W V1
Z S a 0 p aj
o
WP0 W=aU)
F-
a
a a3a
11
1/2' GLASS BITE
•
4 ,,% �1oa�8�t
• • �' w
' 30
•
16
• • •
No 582 1•
tiUl
•
••••••
ro ; a
• �: ST47E OF S[v
ol
GLASS TYPE B
SASH GLASS
••••••
••
• •••••
• • • •
• •
•
•
• • • • • • • •
•
• ••••••
••
••• 9/ 2017
0.6
•
• 6LICAS A. tL%tAjlP.E.
•
• FL PE # 58201
•
• • 1239 JABARA AVE.
NORTH PORT, FL 34288
PH.941-380-1574
GLAZING DETAILS
TEF 10/11/13
/G #: REV.:
CWS-869 C
ALE: SHEET
1:1 2 OF 6
INTERIOR
SECTION VIEW A -A
INTERIOR
SECTION VIEW B-B
SECTION VIEW C-C
ALTERNATE FIN FRAME
SECTION VIEW D-D
JAMB ROTARY LOCKS
JAMB ROTARY LOCKS:
MAY BE SUBSTITUTED FOR JAMB
IMPACT LOCKS ON FLANGE UNITS.
REQUIRED ON FIN UNITS.
• •
• •
HEAD IMPACT HOOK (TYP.)
• • •
MIDSPAN OF SASHES
F(ITEMS 44 & 46)
• • • • • •
•
- -
••••••
• •
••
• •
.• ••
JAMB IMPACT HOOKS (ITEM 42)
• • • • • •
OR ROTARY LOCKS (ITEM 23)
• • •
LOCATED AT THIRD POINTS.
• •
•
X
i
NOTES:
• • •
EITHER IMPACT HOOKS OR ROTARY LOCR9 •
MUST BE USED IN BOTH JAMBS OF FLANGE UNITS.
ONLY ROTARY LOCKS MUST BE USED IN BOTH
JAMBS OF FIN UNITS.
HEAD IMPACT HOOK AND
JAMB IMPACT HOOK/ROTARY LOCK LOCATIONS
1:20
WINDOW SYSTEMS L
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
www.cws.cc
8200 PVC
HORZ. SLIDER
IMPACT
a i 3 ¢z3:
I- QwQ aw0o
o
zwz O�z w
U.Pw3z�3mx
z z=m¢XwOQ
O OI-O mo
U ¢=w
U z -U)-ZI-tea
z Q � �jU-
¢ HZLL200OLLZ
tr i� ~c~i~zvi
w QO�v}iOW(oW
U. S2Z:r ui QJ(AF
a.
a womw
o- I.- a. W a
•
•
• • S�jG�••�lciii �ri2�
No 58201 • i �7
• <�i;
•••w-0
•*i••••�a
iM STAZE OF •;mow,
••
•�OS•14H...•'(y'``�
•
• •
•
• • • 9/2 /2017
•
o6UCAS A. tWFT,p.E.
•
• FL PE # 58201
•
• • 1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SECTION VIEWS
TEF 10/11/13
IG #: REV.:
CWS-869 C
ALE: SHEET
1:2 3 OF 6
PARTS LIST
ITEM PART # DESCRIPTION
1 H-6049 Main Frame, SH/HS, Flange, PVC
2 H-1681 Fixed Rail, Heavy Duty, Aluminum
3 S-6077 Cover, HD Fixed Rail, PVC
5 P-4638 #8 x 2 112" Ph Mod Truss Type A'
6 P-3342 Seam Sealer, SM5504
7 S-1776 lRoller Track
8 S-6013 Screen Adapter, Jamb, PVC-
9 S-6014 Screen Adapter, Head & Sill, PVC
10 P-4479 Weep Coverw/ Flap
11 S-6064 Glazing Bead
12 H-6050 Sash Meeting Rail, PVC
13 H-6051 Sash Pull Rail, PVC
14 H-6052 ISash ToWBot. Rail. PVC
VENDOR MATERIAL 31/8"-1
Mikron PVC
Keymark Alum MikronPVCAjax Steel2 11/16"L#k
3 9/16"
Schnee Silicone
Keymark Alum
Mikron PVC
Mikron PVC PVC FRAME FLANGE-6049
M&M Nylon
Mikron PVC
Mikron PVC
16
H-1498 lReinfbircement.
Sash, Side Rail
Keymark
Alum
17
H-1699
Reinforcement, Sash Pull Rail
Keymark
Alum
18
P-3429
Wstp., 0.270 x .187 back FinSeal, Gn
Uftrafab
19
P-3783
Lock, Impact, PVC
Interlock
20
P-4051
#8 x 1 1/4" Ph Flat Tek, Wht.
Fastenal
Steel
21
P-4069
Keeper, Impact, PVC
Interlock
22
P-3539
#8 x 3/4" Square PH Tek, Wht.
Fastenal
Steel
23
P-4958
IRotary Lock
Interlock
24
P-4633
8-32 x 1/2" Barrel Fastener
Interlock
25
P-4952
Keeper, Rotary Lock
Interlock
26
P-4779
Roller, Tandem
M&M
Nylon
27
P-3541
#8 x 1/2" Quad PH TEK 2 Zinc
Fastenal
Steel
28
GLASS
SEE SHEET
CARDINAL
GLASS
29
Purfect Glaze'H• or Sikaftex 552
Henkel/Sika
Silicone
30
P-3028
Set. Blk., 85 Our., 1/8' x 7/8" x 2" Lg.
Frank Lowe
Rubber
31
P-3218
Screen Frame
Allmetal
RollForm
32
P-4754
Screen Comer Key
Allmetal
Nylon
33
P-4755
Screen Comer Key w/Safety Tab
Allmetal
Nylon
34
P-3029
Screen Pull tab
Summit
35
P-3033
Screen Spring
Fla. Spring
SS
36
P-3228
Screen Spline
Dapa
37
P-4772
Screen Cloth, Fiberglass
40
P-3113
Screw Support, PVC
Team Plastics
Rubber
41
P-3752
Cap Plug, 1/2" Hole
M&M
Nylon
42
S-1577
Impact Hook, Frame, Jamb
Keymark
Alum
43
S-1112
Reinforcement, Head, Jamb
Keymark
Alum
44
S-2000
jimpact Channel, Sash
Keymark
Alum
45
P-3748
#6 X 5/8 Ph FH TEK, Zinc, Painted
Ajax
Steel
46
S-1999
Impact Hook, Frame, Head
Keymark
Alum
47
H-6048
Main Frame, SH/HS, Fin, PVC
Mikron
PVC
48
S-6055
Roller Track, PVC, (Anti -lift)
Mikron
PVC
49
P5250
Lock, Impact, PVC, w/Flipper
Interlock
50
P-4730
#8 x 1/2" Ph Mod Truss TEK
Fastenal
Steel
3 1I8'
1/16" 1 7/8"
L tllf
HD MTG RAIL-1681
PVC FRAME FIN-6048
CORNER CONSTRUCTION
CORNER WELD
(ALL SIDES)
1:8
6
2 3/16' 1 15/16" S
f'— � �--23/i6'
1 14 3
13
15I/8" 15/8• 15/16'
1/16• i q W13" q 1/16" — ,N6" 2
PVC SASH MTG. RAIL-6050 PVC SASH SIDE RAIL-6051 PVC SASH TOP/BTM RAIL-6052 PVC HD MTG RAIL COVER -
3116
O
L 6"
1 5/16"
46
7/8" 1/16"
PLAN VIEW-1999
HEAD IMPACT HOOK - 1999
0 3/16"
O
L 6"
5/8"
�
1/16"
PLAN VIEW-2000
PANEL IMPACT CATCH - 2000
0 3/16"
O
1 5/16"
7/8'
4
PLAN VIEW - 1577
ALUM SASH IMPACT HOOK- 1577
3/16" t I- 3" -{ 1/2"
I I
4D
r
SCREW SUPPORT -3113
WINDOW SYSTEMS B
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8200 PVC
HORZ. SLIDER
IMPACT
a z 3 az�
F pw0 Owoo
O 7(0i ZOZ OwZm
a 3}Z 3_
U. z=2¢�wOp
0 OHO Q=Ifw
U 0 Z (L te a
Z Q �50-
PZLL2000LLZ
w 0Ow(nawmw
D zya O-jm�
ya•� X = w a=ulv}i
- 3/4• d � a. w (L
1• 15 � 1
T� �r4u�n1ip�
L 1116 15/16' • • • P' 10111
SASH MTG. RAIL-1497 L II�� • % I -I'
�GENS••;�•Q��i�
SA41 REIWFP,.1699 • • •+�� : No 58201 � 9
•• • •i•t •
76
7 a9 STAiE OF
S.B.R./S.S.R. -1498 • • • • ✓i�� S1/16 /0ffyy�t •�N,�p
ROLLER TRACK - 1776 • • • 'so"'Nr' •
•••••• •• • •••••
„ •'�-Ifs . .. ......
9l1(# II j Lip - • • • •L•--• •
PVC GLAZ -READ - 6064 tl •� 1/16' • • • • • 9/2ti2017 •
GLAZE BEAD► 1112
• • • • e1.j1CAS A. Ti1RRIM, t.E.
t/2"/e y • • • FL PE # 58201
3/8• , 5116• -{ • • • • 1239 JABARA AVE.
8 8 NORTH PORT, FL 34288
1/16•� PH.941-380-1574
PVC SCREEN CATCH - 6013 1/16" SHEET DESCRIPTION:
PVC ANTI -LIFT - 6005
FD(ED MEETING RAIL
SCREWED TOGETHER WITH
OUTERFRAME
1:8
1 1/8" y
s/1s• I
BOM AND EXTRUSIONS
9
DRAWN BY:
DATE:
T— 1/16'
TEF
10/11/13
PVC SCREEN SUPPORT - 6014
DWG #:
REV.:
CWS-869
C
OTHERWISE NOTED.
SCALE:
1:2
SHEET
4 OF 6
LINE ITEMS NOT USED:
4, 38-39 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS
3" (TYP.)�'I
6" MAX (TYI
6" MAX (TYI
17"
MAX O.C.
(TYPJ
ANCHORLAYOUT- (FLANGE)
OTE 2
INSTALLATION
ANCHOR(TYP.)
4" MAX (TYP.)-
4• MAX (TYP.)-
8" —
MAX O.C.
(TYP•)
�{ �8' MAX. O.C. (TYP.)
X
O
X
ANCHOR LAYOUT - (FIN)
••1•••
•
••••••
WINDOW SYSTEMS LS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
8200 PVC
HORZ. SLIDER
IMPACT
z 3 ¢z3
❑Wo awoo
0 7cw 0=Zm
¢ 3> 3_
z z=�Z¢�W00
O OHO Q=Fa
U 0t -za-HrnD-
Z O � �jU-
¢ zoozo U
i3oWomoz
0a Z�
w 2!L' 0Wrn�
a
o WH0 Ir W=�N
a F a W ,
•0
• • -%-I,�0ENS `�4
•Pii22i
• N. SUR �• t�9
:tit• •• ;*C
•
*
•i a' •••••• fz'L
STATE OF tut
• • • •
• • • • •
NA1-e 0-
• • hNfA�tiAlilf
NOTES:
•••••• ••
• •••••
1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. • • • •
•
•• •• •
•• ••••••
2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARIN6091PI"6HALL BE
• / '9 • •
CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. • • •
f^�' •
3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. • • : • •
• • • 9/22/201 /
• • •
LUCAS A. TtIR11LR, P.E.
4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATEL?*00& MUST •
• • • FL PE % 58201 •
BE PROTECTED TO PREVENT REACTION. • •
• • 1239 JABARA AVE.
5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM
NORTH PORT, FL 34288
SPECIFIED IN TABLE 1, SHEET 6.
PH. 941-380-1574
6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE.
ANCHOR SCHEDULE AND
INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
NOTES
7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL.
DRAWN BY:
DATE:
TEF
10/11/13
8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE.
DWG 8:
REV.:
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.
CW S-869
C
9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS:
SCALE:
SHEET
FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS), FMA/AAMANVDMA 300(E)(TERIOR DOORS)
1 :25
5 OF 6
TYPICAL HEAD ANCHORAGE
MIN. EDGE DIST.
SEE TABLE 1
SUBSTRATE BY OTHERS
SEE TABLE 1
MIN. EMBEDME
PERIMETER SEALANT
SEE TABLE 1
BYINSTALLER
INSIDE AND OUT
SEALANT BEHIND
FLANGE BY INSTALLER
1/4' MAX. SHIM
INSTALLATION ANCHOR
SEE TABLE 1
1/4" MAX. SHIM
SEALANT BEHIND
FLANGE BY INSTALLER
PERIMETER SEALANT
MIN. EMBEDMENT
BYINSTALLER
SEE TABLE 1
INSIDE AND OUT
SUBSTRATE BY OTHERS
SEE TABLE 1
MIN. EDGE DIST.
A VERTICAL
8 TYPICAL
SEE TABLE 1
SECTION
SILL ANCHORAGE
MIN. EMBEDMENT
SEE TABLE 1 SUBSTRATE
BY OTHERS
1/4' MAX. SHIM SEE TABLE 1 MIN. EDGE DIST.
SEE TABLE 1
1/4" MAX. SHIM -
MIN. EDGE DIST.
SEE TABLE 1
INSTALLATION ANCHOR
SEE TABLE 1
PERIMETER SEALANT
BY INSTALLER
INSIDE AND OUT
SEALANT BEHIND
FLANGE BY INSTALLER
Ln 11 HORIZONTAL SECTION
�/ TYPICAL JAMB ANCHORAGE
TABLE 1: APPROVED INSTALLATION
FASTENERS
F
TYPE
ANCHOR TYPE
MIN. EMBEDMENT-
FLANGE
CONCRETE (2.0 KSI MN.)
3/16" ITW TAPCON
1-1/2"
1-1/8"
F
FLANGE
OUT FLLED CMU (117 PCF MN.)
CONCRETE (2.85 KSI MN.)
3/16" ITW TAPCON
3/16" ELCO ULTRACON
1"
1"
FLANGE
GROUT -FILLED CMU (ASTM C-90)
3/16" ELCO ULTRACON
1-114"
2-1/2'
FLANGE
2XMN. SOUTHERN PINE (G=0.55)
3/16" ITW/ TAPCON
OR ELCO ULTRACON
1-318"
7/8"
FLANGE
2XMN. SOUTHERN PINE (G=0.55)
#10 WOOD SCREW
1-3/8"
7/8"
FLANGE
16 GAUGE (0.060") MIN. STEEL STUD
(33 KSI YIELD MIN)
#10-16 HLTI KW IK-FLEX OR ITW
TEKS SELF -DRILLING SCREW
FULL THREAD
THRU 0.D60"
7116"
FLANGE
1/8" ALUM. (6063-T5 MIN.) OR
1/8" STEEL (33 KSI MN.)
#10 GRADE 5 SELF -TAPPING/
DRILLING SCREW
FULL THREAD
THRU 0.125"
7/16"
FIN
2XMN. SOUTHERN PINE (G=0.55)
#8 WOOD SCREW
1-1/2"
1/2"
:>ERIMETER SEALANT
BYINSTALLER
INSIDE AND OUT
SUBSTRATE WINDOW SYSTEMS B
BY OTHERS 1900 SW 44TH AVE.
SEE TABLE 1 OCALA, FLORIDA 34474
W W W.CW S.CC
SEE TABLE D1
PERIMETER SEALANT
8200 PVC
HORZ. SLIDER
IMPACT
Z
z 3 az3
wwoW
w-j a
BY INSTALLER
W
Q� Z
NSDEAND OUT
O
Qy3}0X3m
INSTALLATION ANCHOR
Z
Z= M a it W Op OO
SEE TABLE 1
O
O
OFO(jQ=FD:
O N F- z CL P rn I
\
SEALANT BEHIND
FIN BY INSTALLER
Z
CO
0 O O- z j U-
Z V W Z
1
6
HORIZONTAL SECTION
Q
O LLV
� p W - H O ?
TYPICAL FIN ANCHORAGE
HEAD AND SILL SIMILAR FOR FIN INSTALLATION
F
<
0 O } 3 O U)
W
LLVIW�QJlNAF
a _
w
w
CL
:r Ir W (A
a a
•
• • •,������Pp10RE
.�•:"�CENg GQ�y
• • •
No 58201 • : ?�
•• •
•
a- a �#
•.gaga •
•
*
04-0' •••••Aa
9: W
*agog*
STATE OF
`O:. _ • btu:
HORIZONTAL SECTION
8 BOX FRAME INSTALLATION
gaga
gaga
••••••
• •
•• ••
gaga••
14#074To�N•
04
• g••••
•
•• gaga••
•
• •
•
•
• • • • 9/22/2017
•
"CAS A. TpRROW P.E.
•
• • FL PE 58201
•
• • • 1239 JABARA AVE.
NORTH PORT, FL 34288
PH.941-380-1574
HEAD AND SILL SIMILAR FOR BOX INSTALLATION
FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,
UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED:
MIN. 1/4' FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED
INSIDE AND OUT, FULL PERIMETER, BY INSTALLER.
PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS
SHOWN FOR FLANGE WINDOWS.
INSTALLATION DETAILS
TEF 10/11/13
VG #: REV.:
CWS-869 C
ALE: SHEET
1:2 6 OF 6
1/4/2018
Florida Building Code Online
Lv
w.ns 'w
' ' • du
BCIS Home I Log In User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search
FI ritla Aft&r
Product Approval
USER: Public User
6a
Product Aooroval Menu > Product or Aoolication
Search > Aoolicatlon List > Application Detail
�
FL #
FL16736-112
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer
Custom Window Systems Inc.
Address/Phone/Email
1900 SW 44th Avenue
Ocala, FL 34474
(352) 368-6922 Ext 245
kpine@cws.cc
Authorized Signature
Kevin Pine
kpine@cws.cc
Technical Representative ]ay Lathrop
Address/Phone/Email 1900 SW 44th Ave
Ocala, FL 34474
(352)368-6922 Ext291
jlathrop@cws.cc
Quality Assurance Representative
Arturo Monteverde
Address/Phone/Email
1900 SW 44th Ave
Ocala, FL 34474
(352) 368-6922 Ext221
amonteverde@cws.cc
Category
Windows
Subcategory
Horizontal Slider
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
U Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Lucas A. Turner
Evaluation Report
Florida License PE-58201
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 07/21/2020
Validated By Steven M. Urich, PE
• • • • • • :R'• %licdptian C.Mcklist - Hardcopy Received
• •• • • • • ••• •
Certificate of Independence • • • • • •'FL1E736, RE 13OI EvalRenort871C.odf
Referenced Standard and Year (of Sj& laFj • • • • d - •
•
' • AAMA/WDMA/1CSA/fOl/I.S.2/A440-08
' •' • • • • • AST M E1886-QS
ASTM E1996-09 •
PA/TAS 201/202/203
••• • • • • ••• • •
• • • • • • • •
Equivalence of Product Standards • • • • • • • • •
Certified By • • • • • • • • • • •
Year
2008
2005
2009
1994
https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDqu8obl%2flZm6TgPohLz6ontOd5HABPugYUIXlzzFJrTCXA%3d%3d 1/2
1 /4/2018
Sections from the Code
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
CRImmwry of Drndueic
Method 1 Option D
09/28/2017
09/29/2017
10/03/2017
12/12/2017
FL #
Model, Number or Name
Description
16736.1
HS-8200 PVC Horizontal Slider
HS-8200 PVC Horizontal Slider, IMPACT, 74" x 63", XO or OX.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16736 R2 II CWS-871C.pdf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +60/-60
Evaluation Reports
Other: Large Missile, 74" x 63", DP +/- 60 psf. Outer lite in
FL16736 R2 AE EvalReport871C.pdf
I.G. must be safety glazed when used above 30 ft. in HVHZ.
Created by Independent Third Party: Yes
Glass complies to ASTM E1300-04.
16736.2
HS-8200 PVC Horizontal Slider
HS-8200 PVC Horizontal Slider, IMPACT, 111" x 63", XOX.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16736 R2 II CWS-869C.pdf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +60/-60
Evaluation Reports
Other: Large Missile, ill" x 63", DP +/- 60 psf. Outer lite in
FL16736 R2 AE Eva IRego rt869C.ndf
I.G. must be safety glazed when used above 30 ft. in HVHZ.
Created by Independent Third Party: Yes
Glass complies to ASTM E1300-04.
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Convriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
Credit Card
Safe
....... . .. ..
. ......... .
• • . • 0.0
.. ... ......
• • 000 • . • 000 •
000
.. . . • •
•
V0.0 ...
https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqu8obl%2fiZm6TgPohLz6ontOd5HABPugYU[XlzzFJrTCXA%3d%3d
2/2
URNER
ENGINEERING &
CONSULTING, INC.
1239 Jabara Ave. .
North Port, FL 34288
Ph. 941-380-1574
FBPE C.O.A. #29779
Evaluation Report 871C
August 29, 2017
Product Description: Series 8200 PVC Horizontal Slider Window, Large Missile Impact (HVHZ), XO
or OX 74"x63" unit size with design pressures of +/-60 psf (Fin or Flange window)
Manufacturer: Custom Window Systems, Inc. 1900 SW 44`h Ave, Ocala, FL 34474
Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC
Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6`h
Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product testing
standards performed are outlined below.
Technical Documentation:
1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL
2) Approval drawing CWS-871 C, signed and sealed by Lucas A. Turner, P.E.
3) Test Reports NCTL-210-3887-1, -lA, -2, and -2A, by National Certified Testing Laboratories,
Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed: TAS 201, 202, 203
`94, ASTM E 1886 `02/04/05, ASTM E 1996 `04/06/09, and AAMA/WDMA/CSA
101 /I. S.2/A440 `08
4) Supplemental Calculations to support CWS-871C, signed and sealed by Lucas A. Turner, P.E.
Installation: Units must be installed according to approval document CWS-871C.
Limitations of Use: This product:
• May be used up to the sizes and daylight openings indicated in CWS-871 C
• Achieves design pressures of +/-60 psf
• Is Large Missile impact resistant and does not require the use of shutters
• May be used in the High Velocity Hurricane Zone
• Requires Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-1117.02t
• Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 17-0206.101
t I have evaluated the materials in these NOAs and find that they comply with the requirements of the
6`h Ed. (2017) Florida Building Code for use in this product.
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial
interest in Custom Window Systems or in any company manufacturing or distributing products for which
this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest
in any other entity involved in the testing or approval process of this product.
�.. ... ORLWQ
Lucas
No 58201
Turner •• •:.
2017-08—:iO
00� *'
e :
16:09+20b0
..' :'o•r ..... ;
STiT�PF00
.: : ..:
0 •.• 0
8/29/2017
Lucas A. Turner, P.E.
FL PE #58201
HORIZONTAL SLIDER -LARGE MISSILE IMPACT GENERAL NOTES: �/��(1�1��]�/J� 1. THE PRODUCT SHOWN HEREIN ISDESIGNED AND MANUFACTURED WIN--DOWSYSTEMS
�•
TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT
EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND 1900 SW 44TH AVE.
IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA, FLORIDA 34474
IN ASTM E 1996 PER THE FBC. WWW.CWS.CC
75 1/4' MAX. OVERALL FLANGE WIDTH
74" MAX. UNIT WIDTH
33' GLASS DLO
64 1 /4'
MAX.
FLANGE
HEIGHT
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS ...........
1
SECTION VIEWS & GLAZING DETAILS....2
EXTRUSIONS & B.O.M...............................3
C
ANCHOR SCHEDULE & NOTES................4
INSTALLATION DETAILS ...........................5
59 9/16"
MAX.
SASH
HEIGHT
2. GLAZING OPTIONS: (SEE SHEET 2)
3. CONFIGURATIONS: "OX". "XO".
4. DESIGN PRESSURE RATING:
-NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND
GLASS TABLES ASTM E-130D-04e01109.
-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER
INFILTRATION TEST PRESSURE AND GLASS TABLES
ASTM E-1300-04e01/09.
5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED
IN THE DESIGN OF THIS PRODUCT. SEE SHEET 5 FOR ANCHOR
DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD
ANCHOR CALCULATIONS.
6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT •
REQUIRED. THE IMPACT ROTARY LOCKS ARE INTENDED T06E LEFT
UNLATCHED DURING NORMAL OPERATION OF THIS PRQ4UCT MBUT
MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE W Ih6S AND
FLYING DEBRIS. • • • • • • •
•
7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOIIQI•IMISEALANT
USED AT FIXED MEETING RAIL AND HEAD/SILL. 0000 •
8. SERIES / MODEL DESIGNATION HS-8200. **see*
•
8200 PVC
HORZ. SLIDER
IMPACT
F-
Z
i 3 az3:
❑WO <
W J I]
W
ZOZ wM_
LL
Z
O
F W
zm:m
�_�w
U
Z
OHO
UyF-ZaFya
p � z~_
• r
Z V 2 Z O LLUU
z
•a
0
�Q3Q0u~i�ibibi
•0a�t}•nOla�nw
of
3 0. Oslo
~ 0 a
a
= • LLJmIr in
CL ow:
••
_d�_uOAfiW�Ji.
9. THE DESIGNATION XAND 0 STAND FOR THE FOLLOWING:' • i • •
�� P�'v�C�r+/wryer';
• �'
X = OPERABLE SASH, 0 = FIXED SASH • • • •
L'N: No •�sx)i • i:� '
10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS INM"1104
i * : +► •
•
LOCATION. • • •
• •
9 • ; a
• �" ST/A'i �OF• w�k/�
11. EXTERNAL WEEP SLOT = 114" x 1" LOCATED 4' FROG BOVFI;. JDS. •
•��
'���•:�( ��1 p!:
•
•• Al- l�0
to lost,
MAX. UNIT SIZE
I DESIGN PRESSURE RATING
IMPACT RATING
74" x 63"
1 +/- 60 PSF
LARGE MISSILE IMPACT
LucasTurne-
r
2017-09-22
9/22/2017
13:58-04:00
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH.941-380-1574
GENERAL NOTES AND
ELEVATIONS
ADE 10/10/13
\ DWG#: REV.:
/l CWS-871 C
SCALE: SHEET
1:15 1 OF 5
INTERIOR
SECTION A -A
SECTION C-C
ALTERNATE FIN FRAME
INTERIOR
SECTION B-B
NOTE: FIXED LITE AT HEAD
AND SILL IS SIMILAR.
HEAD IMPACT HOOK (TYP.)
MIDSPAN OF SASH
(ITEMS 35 8 36)
X
HEAD IMPACT HOOK AND
JAMB ROTARY LOCK LOCATIONS
1:20
ROTARY LOCK (TYP.)
ONLY ENGAGED PRIOR
TO HURRICANE FORCE WINDS.
LOCATED AT THIRD POINTS
(ITEM 27)
WINDOW SYSTEMS L
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8200 PVC
HORZ. SLIDER
IMPACT
S z 3 az�
I- Ow0 awnno
w zoz wm=L
Ow ~w�ZO�:m=
Z ZSm<mwp0
O OFO ¢=Fw
0 UtnF-ZdFV)a
0 z0U)-ZFZ)Un
• O-50
zou)ZO
• •F_IL20IL
.. •
•:
.w
On
•
Z=Wrno��Lu
hs••••s
••••••
iF0•w=i
•••• •
d
F CL L•
•
•••�NDRtiW�'fIi
• • •
•••• •
..
.. •
•�•�� tNo •6CiW • ��� r
7/8' OVERALL • •
b : • • a=
ate, STAIR a7F• 4C�4u-
• •
1/8• ANNEALED or TEMPERED •
• •1
i .p :,R
7/16' AIRSPA-1E •
�AO}l1At- c
• ���plup�i���
5/16' LAMI •
• •
1/8' ANNEALED
= DUPONT PVB INTERLAYER
1/8' ANNEALED
9/22/2017
3 PURFECT GLAZE-H'
LUCAS A. TURNER, P.E.
SIKAFLEX 552
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRPTIDN:
1/2' GLASS BITE
K
SECTION VIEWS AND
QUANE X DURASEAL
GLAZING DETAIL LIG
SPACER
DRAWN BY:
DATE:
ADE
10/10/13
DWG #:
REV.:
CWS-871
C
SCALE:
1:2
SHEET
2 OF 5
SETTING BLOCKS PER FBC 2411.3.3.1
PARTS LIST
ITEM
PART #
DESCRIPTION
VENDOR
MATERIAL
1
H-1497
Reinf. Sash Meet. Rail
Keymark
Alum
2
H-1699
Reinf. S.B.R./S.S.R,
Keymark
Alum
3
H-1836
Meet. Rail, Fxd.
Keymark
Alum
4
H-6052
Sash Top/Bot. Rail
Mikron
PVC
21
5
H-6048
Main Fr.. SH, w/ Fin.. PVC
Mikron
PVC
6
H-6050 ISash
Most. Rail, PVC
Mikron
PVC
7
Hf051
Sash Side Rail, PVC
Mikron
PVC
8
H-6049
Main Fr., SH, w/Fig., PVC
Mikron
PVC
9
P-3029
Screen Pull Tab
Summit
10
P-3033
Screen Spring, SS
Hurley
11
P-3113
Screw Support, PVC
Team Plastic
Rubber
12
P-3218
Screen Frame
Allmetal
RollFomm
13
P-3228
Screen Spline, .155 Dia., Bilk.
Dapa
14
P-4754
Screen Frame Comer Key
Allmetal
Nylon
15
P�3342
Seam Sealer, SM-5504
Schnee
Silicone
16
P,3352
Set. Bilk., 85 Dur., 1/8" x 5/8" x 2' Lg.
FrankLowe
Rubber
17
P-3429
Wstp., 0.270 x .187 back FinSeal, G
Ultrafab
18
P-3539
#8 x 314" Square TEK 2 Zinc
Fastenal
Steel
19
P-4730
#8 x 1/2" Truss PH TEK 2 Zinc
Fastenal
Steel
20
P-3752
Cap Plug, 1/2" Hole
M&M
Nylon
21
- or
P-5250
Spring Lock, Impact, PVC
Interlock
22
P-4779
Roller, Tandem
M&M
Nylon
23
P-4051
#8 x 1 1/4 Ph FH TEK, Wht.
Fastenal
Steel
24
P-4069
Keeper, Impact, PVC
Interlock
25
P-4479
Weep Cover w/ Flap
M&M
Nylon
26
P-4638
#8 x 2 1/2 Ph Truss SMS
Ajax
Steel
27
P-4958
Rotary Lock
Sullivan
Znc
28
P-4952
Keeper, Rotary Lock
Sullivan
Zinc
29
P-4959
Wstp., 0.420 x .187 back FinSeal, Gn
Ultrafab
30
P-4633
Barrel Fastener
Fastenal
Steel
31
S-1112
Reinforcement, Head
Keymark
Alum
32
S-1498
Reinf. S.B.R./S.S.R,
Keymark
Alum
34
S-1776
Roller Track
Keymark
Alum
35
S-1999
Frame Hook, Head, Impact
Keymark
Alum
36
S-2000
Panel Catch, Head, Impact
Keymark
Alum
37
S-6005
Anti Lift
Mikron
PVC
38
S-6013
Scm. Adapt., w/ Nib, PVC
Mikron
PVC
39
S-6014
Scm. Adapt., PVC
Mikron
PVC
40
S-6063
Fixed Rail Cover
Mikron
PVC
41
S-6064
Glazing Bead
Mikron
PVC
42
GLASS
SEE SHEET
CARDINAL
GLASS
43
Purfect Glaze "H". SikaFlex 552
lHenkel/Sikal
Silicone
3
PVC FRAME FLANGE-6049
3 1/8"
3
5
9/16' O 2 1/8' 1/16'
i� 1'
FIXED RAIL - 1836
PVC FRAME FIN-6D48
r-23/16' /�j 'j 9116°
IL
7 &1/16
1 5/8' q 1 5/16'
1/16' 1/16""
PVC SASH MTG. RAIL-6050 PVC SASH SIDE RAIL-6051 PVC SASH TOP/BTM RAIL-6052 PVC FIXED RAIL COVER- 606
0 3/16'
0
ir= 6" t 5/16'
35
7/8' 1116"
PLAN VIEW-1999 HEAD ACT HOOK -1999
$ 3/16"
O
I 6. 5/8"
T— 36
PLAN VIEW-2000 PANEL IMPACT CATCH -2000
3/16"
3- --1 —1/2'
r
SCREW SUPPORT-3113
LINE ITEMS NOT USED: NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED.
33
1' � 1
1/16'
SASH MTG. RAIL-1497
3/16" 3/4'
r 3
1/16'
S.B.R./S.S.R. - 1498
t/4
1
PVC GBEAD - 6064
CORNER CONSTRUCTION Q.,,q
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
CORNER WELD
(ALL SIDES) 8200 PVC
1:8 HORZ. SLIDER
IMPACT
15
6 Q z QZ3
F C LUO aWOpW
Z WJ0
W ZOZ Qf=00=Zm
z Z=2 WWOO
FDCED MEETING RAIL O O I- O t j Q=� X
SCREWED TOGETHER WITH O O f� Z 0- H ,n A
OUTE1:8 Z 7 U
3 1:8 •a; }ZO1OZOLLMOu_U
i�OI•�b
• • •• 2 •- 'Lora. OJ d♦H
• • ?=a •U,
15It6' •s/Rf
166 UPOO o.X
SASH,e IV.!'V99 • , ►u n, •
• • •,���� PtlDibl::yiii�i
Ins" s&W/a; . de•���p!,��•'Ay',
• • •• �.
34 • 41.6 J No Zili • j,-P
ROLA TRACK! 1776 � • • � STAND 4W. Ww
7— 31 • • •
9/16L
1116'
GLAZE BEAD -1 t 12 y�
1/2"
11/8"-j
3l8" 5//16"j
9/22/2017
38
�
�1_r, -LJ
LUCAS A. TURNER, P.E.
1/16"
L- 1116•
FL PE # 58201
PVC SCREEN CATCH - 6013
PVC ANTI -LIFT - 6005
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
5/16" � 1
SHEET DESCRIPTION:
39
BOM AND EXTRUSIONS
1/16'
PVC SCREEN SUPPORT - 6014
DRAWN RV' I nATF•
ADE 10/10/13
IG #: REV.:
CWS-871 C
ALE: SHEET
1:2 3OF5
12 1/2' MAX. O.C. (TYP.
6- MAX. (TYP.)
6" MAX. (TYP.)
17'
MAX. O.C.
(TYP.)
L
3" (TYP.)
3" (TYP.) SEE
I
1
I O
I
r
I I
I
I X I
I I
ANCHOR LAYOUT -(FLANGE)
NOTE 2 4" MAX (TYP.)
4- MAX. (TYP.;
INSTALLATION
ANCHOR (TYP.)
8' -
MAX O.C.
(TYP.)
�8' MAX. O.C. (TYP.) ,
I
I
I
I O
1
I
I
I v
I ^
1
I
I
I
I
I
ANCHOR LAYOUT - (FIN)
EE NOTE 2
•— INSTALLATION
ANCHOR (TYP.)
Dwlbm'
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
8200 PVC
HORZ. SLIDER
IMPACT
Z 3 4Z0
OwO NW-Dw
p
ZOZ wz
afn3�Z0W
Z 2 m< W W O p
OI-O ¢=Fw
000�-ZaE-UI-
Z-j-ZE-p(q
OZUwZ�U-
•E-a-li2
p��p��=.,..0Z
c;0
•pp
Q(AaW
_~W0.• w3wy�
•r r
J
• s.
•
NOTES: •
1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD.
2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16' IS PRESENT. LOAD BEARING SHIMS SHALL BE
CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 5.
4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST
BE PROTECTED TO PREVENT REACTION.
5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM
SPECIFIED IN TABLE 1, SHEET 5.
6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE.
INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL.
8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE.
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 5. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.
9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS:
FKWAAMA100(FINWINDOWS),FMA/AAMA200(FLANGEWINDOWS), FMANVDMA250(BOXWINDOWS),FMA/AAMANVDMA300(EXTERIORDOORS)
No"2W•r15
• a
srAtt VF• a LU,
g�aNA1.�r�.
z�
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
ANCHOR SCHEDULE AND
NOTES
ADE 1 10/10/13
CWS-871 C
:ALE: SHEET
1:20 4 OF 5
MIN. EMBEDMENT
TYPICAL HEAD ANCHORAGE
SEE TABLE 1
SUBSTRATE
BY OTHERS
MIN. EDGE DIST.
1/4' MAX SHIM
SEE TABLE 1
SUBSTRATE BY OTHERS
SEE TABLE 1
SEE TABLE 1
MIN. EDGE DIST.
MIN. EMBEDMENT
SEE TABLE 1
PERIMETER SEALANT
SEE TABLE 1
BY INSTALLER
INSTALLATION ANCHOR
INSIDE AND OUT
SEE TABLE 1
SEALANT BEHIND
/
FLANGE BY INSTALLER
1/4- MAX SHIM
INSTALLATION ANCHOR
SEE TABLE 1
SEALANT BEHIND
FLANGE BY INSTALLER
PERIMETER SEALANT
-
BYNSTALLER
INSIDE AND OUT
SUBSTRATE BY
SEE TABLE 1
1/4" MAX SHIM
MIN. EMBEDI
SEE TABLE 1
MIN. EDGE DIST.
\ SEE TABLE 1
l A\1 VERTICAL SECTION
,5 TYPICAL SILL ANCHORAGE
PERIMETER SEALANT
BY INSTALLER
INSIDE AND OUT
SEALANT BEHIND
FLANGE BY INSTALLER
BBHORIZONTAL SECTION
5 TYPICAL JAMB ANCHORAGE
TABLE 1: APPROVED INSTALLATION
FASTENERS
TYPE
ANCHOR TYPE
MIN. EMB
CONCRETE (2.0 KSI MIN.)
3116" TTW TAPCON
1-1/2"
1-1/8'
117 PCF MIN.
3/1W ITW TAPCON
FFLANGE
CONCRETE (2.85 KSI MN.)
3116" ELCO ULTRACON
1'
1'
GROUT -FILLED CMU (ASTM C-90)
3/16" ELCO ULTRACON
1-1/4"
2-1/2"
2XMN. SOUTHERN PINE (G=0.55)
3/16" TIW TAPCON
OR ELCO ULTRACON
1.3/8"
7/8"
FLANGE
2XMN. SOUTHERN PINE (G=0.55)
#10 WOOD SCREW
1-3/8"
7/8"
FLANGE
16 GAUGE (0.060") MN. STEEL STUD
(33 KSI YIELD MN)
#10-16 HILTI KWIK-FLEXOR ITW
TEKS SELF -DRILLING SCREW
FULL THREAD
THRU 0.060"
7/16"
FLANGE
1/8" ALUM. (6063-T5 MIN.) OR
1/8" STEEL (33 KSI MIN.)
#10 GRADE 5 SELF -TAPPING /
DRILLING SCREW
FULL THREAD
THRU 0.125"
7/16"
FIN
2XMN. SOUTHERN PINE (G=0.55)
#8 WOOD SCREW
1-1/2"
1/2"
PERIMETER SEALANT
BYINSTALLER
INCR]F ANn (111T
WINDOW SYSTEMS �lv
MIN. EDGE DIST.
SEE TABLE 1
SUBSTRATE
BY OTHERS
1900 SW 44TH AVE.
SEE TABLE 1
WW W FLORIDAS.CC 34474
1/4" MAX SHIM
8200 PVC
L1
HORZ. SLIDER
MIN. EMBEDMENT
SEE TABLE 1
IMPACT
a
i 3 <Zo
PERIMETER SEALANT
Z
W J O a F WF O LU
F Z
BY INSTALLER
INSIDE AND OUT
W
O
Z O Z W I -
Q U) 3 O K 3 m
INSTALLATION ANCHOR
LL
Z
O
Z}Z
Z I m Q~ 3 o_
SEE TABLE 1
0
OI-OLj�=OW
F- Z Z~
SEALANT BEHIND
Z j
FIN BY INSTALLER
• Z
i
p Z V uj Z O U
�C HORIZONTAL SECTION _ •
•
•F 3 OW _O = LL
O Z
V TYPICAL FIN ANCHORAGE
HEAD AND SILL SIMILAR FOR;IjIwb•fAvTION
•
Q
M -
w to j 3
00
•ZNW(AO�<OW
•••�••
•
•—
••••••
=a•$q
i~I•w3wO
••••
•
a
� °-•C••�•
• •
•
• •
• •
• • • •
•
•
• 2, � b iNR,"7�
• i;�
031li : No •%*Vcz
• • •
•
•
•
•
9' srAt wove ft"W
00
E HORIZONTAL SECTION
5 BOX FRAME INSTALLATION
HEAD AND SILL SIMILAR FOR BOX INSTALLATION
FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,
UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED:
MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED
INSIDE AND OUT, FULL PERIMETER, BY INSTALLER.
PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS
SHOWN FOR FLANGE WINDOWS.
r
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
INSTALLATION DETAILS
ADE 10/10/13
VG #: REV.:
CWS-871 C
:ALE: SHEET
1:2 5 OF 5