RF-19-843Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address 9510 NW 1ST AVE, Miami Shores, FL 33150 Contacts Issue Date: 04/18/2019 Parcel Number 1131010240260 Permit o.: RF-04-19-U3 Permit Type., 1100f Work,Ctassification: Flat Permit,Status: Approved Expiration: 410/ 15/2019 MEI LIN ALCOCER Owner AJF ROOFING INC Contractor 9510 NW 1 AVE, MIAMI SHORES, FL 33150 ALEJO FERNANDEZ Other: 7866381353 7495 NW 7 ST, MIAMI, FL 33126 Business: 3054568006 Mobile: 3059708006 Description: RE -ROOF FLAT WITH TPO Valuation: $ 3,800.00 Inspection Requests: 305-162-4"q Total Sq Feet: 500.00 Fees Amount Application Fee - Other $50.00 CCF $2.40 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $0.80 Roofing Fee $200.00 Scanning Fee $12.00 Technology Fee $6.25 Total: $277.70 Building Department Copy Payments Date Paid Amt Paid Total Fees $277.70 Check # 1704 04/18/2019 $277.70 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws c regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. �(1��� Authorized Signature: Owner / Applicant / Contractor / Agent Date April 18, 2019 1 Page 2 of 2 4 DECEIVED Miami Shores Village PR 1 8 2019 Building Department By 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC ❑■ ROOFING �� F BC 20 C� - Q Master Permit No. _-0 ` rn—v Sub Permit No. ❑ REVISION ❑ EXTENSION [:]RENEWAL PLUMBING ❑ MECHANICAL OPLIBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOBADDRESS: 9510 NW 1 AVENUE City' Miami Shores County: Miami Dade Zip: 33 C S0 Folio/Parcel#:11-3101-024-0260 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: OWNER: Name (Fee Simple Titleholder): MEI LIN ALCOCER Address:9510 NW 1 AVENUE City: MIAMI SHORES State: FL BFE: FFE: Phone#: Zip: 33150 Tenant/Lessee Name: SAME AS OWNER Phone#: Email: V-P-ILL I N `-�49 �UB� CONTRACTOR: Company Name: AJF ROOFING INC Phone#: 305-456-8006 Address: 7495 NW 7 STREET SUITE#10 City: MIAMI State: FL Zip: 33126 Qualifier Name: ALEJO FERNANDEZ Phone#: 305-970-6359 State Certification or Registration #: CCC:1331111 DESIGNER: Architect/Engineer: Certificate of Competency #: Phone#: Address: City: State: Value of Work for this Permit: $ 3800 Square/Linear Footage of Work: 500 Type of Work: ❑ Addition ❑ Alteration ❑ New 0 Repa r/Replace Description of Work: RE -ROOF . q e>-F W iT H- TPO Specify color of color thru the: Submittal Fee $, Scanning Fee $ Technology Fee $ Structural Reviews $ 31211 Permit Fee $ Radon Fee $ Training/Education Fee $ CCF $ DBPR $ Zip: ❑ Demolition CO/CC $ Notary $ Double Fee $ Bond $ E-� 0� TOTAL FEE NOW DUE $ ' �D (Revised02/24/2014) y Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address Zip City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and aAinspection fee will be charged. I Signature)M-/L � Signature �lYl— OWNER or AGENT The foregoing instrument was acknowledged before me this The foreping instrument was acknowledged before me tnls day of 20 9 by 4" davooff i 20 19 by who is personally known to o is personallykn me or who has produced_ as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: QSign: Sign: Print: JAN TTE DIAZ Print: Sf ']TE �iJ71QcZ Seal: JANETTE DIAZ Seal: ° JANETTE DIAZ MY COMMISSION # GG035634 ;;Q • " EXPIRES O Ober 04, 2020 `: MY COMMISSION # GG035634 EXPIRES October 04, 2020 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Property Search Application - Miami -Dade County https://www8.miamidade.gov/Apps/PA/propedysearch/#/report/s... If OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3101-024-0260 9510 NW 1 AVE Property Address: Miami Shores, FL 33150-1702 ------------------------------------ FABIO GIL CEBALLOS Owner MEI LIN M ALCOCER 9510 NW 1 AVE Mailing Address MIAMI, FL 33150 USA PA Primary Zone 0800 SGL FAMILY - 1701-1900 SQ 0101 RESIDENTIAL -SINGLE Primary Land Use FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area 2,436 Sq.Ft Living Area 1,799 Sq.Ft 2,078 Sq.Ft Adjusted Area Lot Size 8,305.5 Sq.Ft Year Built 1965 Assessment Information Year 2018 2017 2016 Land Value $182,704 $182,704 $182,704 Building Value $202,605 $238,035 $241,048 XF Value $1,352 $1,355 $1,359 Market Value 1 $386,661 $422,094 1 $425,111 Assessed Value 1 $374,165 $366,470 $358,933 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $12,496 $55,624 $66,178 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description BONMAR PARK PB 17-11 LOT 5 & N1/2 OF LOT 6 BLK 5 LOT SIZE 73.500 X 113 OR 9774-0516 Generated On : 4/17/2019 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $507000 $50,000 Taxable Value 1 $324,165 $316,470 $308,933 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value 1 $349,165 $341,470 $333,933 City Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $324,165 $316,470 $308,933 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $324,165 $316,470 $30823 Sales Information Previous OR Book- Price Qualification Description Sale Page 12/16/2013 $418,000 28973-3625 Qua[ by exam of deed Not exposed to open -market; atypical 03/05/2013 $250,000 28536-3795 motivation Trustees in bankruptcy, executors or 03/04/2013 $199,700 28526-1170 guardians 08/01/1977 1 $62,000 09774-0516 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Mami-Dade County assumes no liability, see full disclaimer and User Agreement at hftp://www.miamidade.gov/info/disclaimer.asp Version: yL ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Sth Edition (2014) 1 High -Velocity Hurricane Zone Uniform Permit Application Form. 1 1 Section A (General Information) i 1 Master Permit No. Process No. 1 Contractor's Name AJ F ROOFING I N C 1 1 Job Address 9510 NW 1 AVE MIAMI SHORES, FL 33150 • 1 1 ROOF CATEGORY 0( Low Slope ❑ Mechanically Fastened Tile ❑ Mortaf/AHQtsslve SeMiil'es .... ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood • • 0 •es/Sha s $11149i ke 0 1. ❑ Prescriptive BUR-RAS 150 000000 • • •00 ROOF TYPE ••"" " ' ""f• ❑ New roof ❑ Repair ❑ Maintenance l� Reroofing •.•..p Recove"Ong .� ROOF SYSTEM INFORMATION : • : • 0000 • Low Slope Roof Area (SF) 481 Steep Sloped Roof AREA (SSF) N-A Total (SF) :48 j • • • • • •� 0000 1 Section B (Roof Plan) 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 1 - 1 a 0 n u 0- LULU I -- s N ■■ 111111■01MMEN0■�1■■■■■■■pm �Im�i■i.. 0-0■O ■ ■I:����....�:IMEMO mum a 31 OWN l■■ ■■■■■Ii■■■■■i■i1N1N_//IPAY, W r- Uff FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) FLO uAnk 15.37 Copyright to, or urtherr by, ICC (ns a RIGHTS RESERVED); accessed by Elie io2 ]0:32:12 ' , Agreement. No further licensed by, ]u C (A L RIGttd. Pursuant to License 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) 1 High -Velocity Hurricane Zone Uniform Permit Application Form. 1 1 1 Section C (Low Slope Application) Top Ply Fastener/Bo ddI M tQ �P�PL�T 1 Fill in specific roof assembly components and identify 14 SCREWS & # 1 1 manufacturer Surfacing: N/A 1 1 (If a component is not used, identify as "NA") 1 Fastener Spacing for Anchor/Base Sheet Attachment: 1 1 System Manufacturer: GAF Field: 6 "oc @ Lap, # Rows 1 @ 55 „ oc 1 1 1 1 Product Approval No.: FL16730-R19 Perimeter: 6 " oc La 1 28 • • — @ p,#Rows_@ 1 1 Design Wind Pressures, From RAS 128 or Calculations: Comer 6 " oc @Lap, #Rows �: • •@� 28 " oc • • • 1 •0 1 P1: -40.11 P2: -67.28 P3: 101.26 Number of Fasteners Per Insulatio�lai3d , 10 , 1 Max. Design Pressure, from the specific product Field N/A Perimeter N/A. • 0 0 • 0 wit ----� • • • • Com • • 1,,,, approval system: -52.5 Illustrate Components Noted and 15AI s as Applicable:0 • 1 • : 0 1 1 Deck: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, BascClIM1FSQg, Counterilashing, • 0000 1 0. 1 Type: CDX PLYWOOD 5/8 = 19/32" Coping, Etc. . . 000000 1 Gauge/Thickness: e/Thickness: 5/8 = 19/32" g Indicate: Mean Roof Height, ParaQet Height, Height of Base Flashing, t,,,,; 1 Component Material, Material Thickness, PaSZener • Slope: 1/4":12" Type, Fastener Spacing or Submit Manufacturers Details that 1 1 Comply with RAS 111 and Chapter 16. 1 1 AnchorBase Sheet & No. of Ply(s): N/A 1 1 1 1 Anchor/Base Sheet Fastener/Bonding Material: 1 1 N/A 1 Insulation Base Layer. N/A FT. N/A 1 1 1 1 1 Base Insulation Size and Thickness: N/A Parapet 1 1 Height Base Insulation Fastener/Bonding Material: 1 1 N/A 1 1 1 1 Top Insulation Layer: N/A FT. 10' FT 1 1 Top Insulation Size and Thickness: N/A Mean 1 1 1 Top Insulation Fastener/Bonding Material: N/A Roof Height 1 1 Base Sheet(s) & No. of Ply(s): N/A 1 Base Sheet Fastener/Bonding Material: >y q O 1 1 N/A o m 1 Ply Sheets) & No. of Ply(s): N/A i 1 Ply Sheet Fastener/Bonding Material: V) 1 1 N/A 1 X O 1 Top Ply: GAF TPO 0.60 MI WHITE MEMBRANE 1 r 1 iR 15.38 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 1 ' I 1 1 1 Copyright to, or licensed by ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form i Section D (Steep Sloped Roof System) 1 1 1 Roof System Manufacturer. 1 Notice of Acceptance Number. 1 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 1 P1: P1: P1: 1 Deck Type: Type Underls Roof Slope: 12 Insulation Fire Ridge Ventilation? Mean Roof Height: �er Type & Spad Adhesive ype Cap S 6 Roof Cov Type & Edge: FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39 Copyright to, or htxnsed by, ICC (ALL RIGHTS RESERVED); aoxssed by Elie= Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agtcetnent. No furthcr reproductions authorized. pLORiDA SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. . . .... ...... 2. _ Renailing wood decks: When replacing roofing, the existing wppdSQof deck maX have to . • •. be renailed in accordance with the current provisions of Section R4403, (The roofdeck is usually. ... .. concealed prior to removing the existing roof system). • • • • • • • • • ...... .. . ..... .. .. .. . ...... 4. _ Exposed Ceiling: Exposed, open beam ceilings are where the MUde of the roof decking '. can be viewed from below. The owner may wish to maintain the architectural appearance; t;ere#ore, "�• • roofing nail penetration of the underside of the decking may not be acceptable.T.Ns provides thg option o • • • • • maintaining the appearance. '.:..' 6. _Overflow scuppers (wall outlets): it is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. I may be necessary to install overflow scuppers in ac ance with the requirements of Sections R44 , R4403 and R4413. X— -11 Uf -'& /t'q Ow Agent's Signature Date Contractor ignature Date 9510 NW 1 AVE MIA SHORES, FL 33150 Property Address Revised on 7/9/2009 LD,07/01/2015; Permit Number Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756,8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. •••• •..,. • 0 0 0 9:0 000 • • • To: Miami Shores Village Building Department 9 9 p •Gknti . � y • ....0 10050 NE 2nd Ave .... • —:"": Miami Shores, A 33138 • • • • • • • • • Re: Owner's Name: FABIO CEBALLOS and/or MEINLIN ALCOCER •• •• • •• •••••• Property Address: 9510 NW 1 AVE MIAMI SHORES, FL 33150 .... . . . . . ' ...... Roofing Permit Number: '..' : . .. :"": Dear Building Official: R e-; Lin lam.0)(ANy that I am not required to retrofit the roof to wall connections of my building because: tfhe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of e South Florida Building Code (1994 SFBC) Ln MCQC_e�. Signature Print Name State of Florida County of Dade JANETTE DIAZ Z •c MY COMMISSION # GG035634 + EXPIRES October 04, 2020 The undersigned, being the first duly swom, deposes and says that he/she is the owner for the Sworn to and subscribed before me this 4411 day of lq Notary Public, Sate of Florida at Large • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 Lab Report No. 129608 FLORIDA TEC PROVIDING SOLUTIONS TO THE ROOFING INDUSTRY C.A. # 30448 Lab Certificate # 17-0703.01 DATE: April 2, 2019 COMPANYNAME. AJF Roofing Inc. PROJECTADDRESS: 9510 NW 1 st Ave., Miami Shores Fastener Spacing Calculations Basic Wind Parameters Wind Load Standard = ASCE 7-10 Exposure Category = C wind Design Speed = 175.0 mph Risk Category = II Structure Type = Building Building Type = Enclosed Building inputs • • • • • • RoofType: Building Roof Type = Flat Flat Roof • = • •••• •••••• RfHt Roof Height = 10.000 ft W Building Width •rr•i32)00 ft •••• •• L Building Length = 37.000 ft OH Type of Overhang - jo,%e •i• • • Parapet Type of Parapet = None Par Is there a Parapet = Salse •••• •••••• OH_ALL None = 0.000 ft 0.•••••• Components and Cladding (C&C) Calculations per Ch 30 Part 2: • • •••••• Theta = Slope of Roof = 0.0 Deg • i LF = Load Factor based upon ASD Design 00 � d•60 • • • • • • • • • • h3 = Per Eqn 30.5-1 use 0.33 * h ••=•-1.300 ft •• • •••••• Kzt = Topographic Factor is 1 since no Topographic feature specified • s•ia000 • •• Lambda = Adjustment Factor for Building Height & Exposure per Fig 30.511 =•1-V10 • • •••••• ••••i• All wind pressures include a load factor of 0.6 : ••• • i••••:• •• • • •• • Description Zone Width Span Area 1/3 Pnet30 Pnet30 p p ••:••• Rule Max Min Max Min ft ----------- ft ft ---- ----- ----- sq ft psf psf psf ----- ---- ------------- ----- psf ------- Field 1 2.000 5.000 10.00 No 22.45 -55.25 16.30 -40.11 Perimeter 2 2.000 5.000 10.00 No 22.45 -92.68 16.30 -67.28 Corner 3 2.000 5.000 10.00 No 22.45-139.48 16.30 -101.26 FASTENER SPACING CALCULATION NOA: FL16730-R19 Fastener Spacine Calculated In Accordance With RAS-137 System Type: W-56 Nbm Design Pressure fe/ Fastener FV Deck Type 52.5 2.29 1 120 Wood Elevated Pressure Zone Max. Fasteners Spacing (inch) Nkm Sheet Width (inch) Field: 40.11 6 55 erimeter: 67.28 6 28 orner: 101.26 6 28 Jorge F.At4lez, P.E. Lic. N 3 2 . 4 ,f Perimeter Width (inch) 36.0 10735 SW 2160' St. Unit 404 Tel: 305-256-4550 www.FloridaTEC.net Miami FL 33170 Page 1 1 Fax: 305-256-6833 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florlda Building Code 5th Edition (2014) 1 High -Velocity Hurricane Zone Uniform Permit Application Form. 1 I 1 Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Me values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. 1 1 Method 1 " oment ased Tile Calculations Per RAS 127" 1 (P1: x _ - - Mg. = Mr, Product Appr 1 M, (P2:_ xX _ - Mg: = MProduct A oval Mr 1 (P3:_ x7l = - Mg: 1 = M,, _ Produ pproval M, • • • • 1 Method 2 1 plifi Tile Calculations r Table Or • • • • • • • 1 Required Moment of Resistance (Mr) From Tab B w Produ Approval M, • • • • • • • • : • 1 • 1 1 1 1 1 I 1 • .••• . • `Must be used in conjunction with list of moment based tile systems endors by the Broward County Board of Rules and 1 Appeals. 1 For Uplift based the systems use Method 3. Compared the values for F with the values for Fr. If the F' values are greater than or 1 equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. 1 Method 3 "Uplift Based Tile Calculations Per RAS 127" (P1:_ x L _ = x w: = _) - W: x cos 6 _ = Fr, Product Approval F' (P2: x L _ = x w: = _) - W: x Cos E) _ = F,2 _ Product Approval F' 1 (P3:_ x L _ = x w: = _ ) - W: x Cos 0 — = F,, _ Product Approval F' 1 1 1 I 1 1 1 1 1 1 1 1 1 1 I 1 1 19 required Momen a tance• Mean Roof Height Roof Slope 15' 20' �5' 30' • • • • • 40' 2:12 34.4 36 .7 ••••.42.2 • 3:12 32.2 .4 0 37.4 • • • •.39.8 4:12 30.4 32.2 34 35.1 • 31.3 5:12 28.4 30.1 31. 32.8 • .34.9 6:12 26 28.0 29. 30.5 32.4 • 7:12 4.4 25.9 27.1 28.2 30.0 Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope A Job Site Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity MG Product Approval Attachment Resistance M, Product Approval Required Moment Resistance Ma Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 1 ! Im 1 114 1 Copyright to, or licensed by. ICC (ALL RIGHTS RESERVED); accessed by Elias Palacio on Jun 8.2015 10:32:12 AM pursuant to License Ag=Ment. No further reproductions authorized. Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wG... 10f11CA OQPAWMM OF usiness & PcofessionSIMUM ai Regu a ion BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications ' Contac b a .� Product Approval d .. USER: Public User Product Approval Menu > Product or Application Search > Application List > Application History > Application Detail 1 OFFICE OF, THE. SECRETAR FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date FL16730-R19 Revision 2017 Approved 0 . . .... .... ...... GAF ...... 1 Campus Drive••• .... ...... • Parisppany, gi0f0�4 ���•�� • (800) 766-341,1• • • • • • • mstieh@gaf.evm••: 009000 ••••• Robert Niemirlen ....:. Ireith@nemoetc.com William Broussard 1 Campus Drive Parsippany, NJ 07054 (800)766-3411 TechnicalQuestionsGAF@gaf.com Roofing Single Ply Roof Systems Evaluation Report from a Florida Registe Florida Professional Engineer ® Evaluation Report - Hardcopy Receiv Robert Nieminen PE-59166 UL LLC 12/17/2021 1 of 3 4/17/2019, 9:57 PM Florida Building Code Online https://www.floridabuilding.org/pr/pi_app_dtl. aspx?param=wG... Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code John W. Knezevich, PE Validation Checklist - Hardcopy Rece FL16730 R19 COI 2018 01 COI NIEh Standard TAS 114 TAS 131 Product Approval Method Method 1 Option D ."". . . .... ...... Date Submitted 12/17/2018•••;•• •••• •••••• Date Validated 12/17/2018*::::� �••••� Date Pending FBC Approval 12/25/2018...... :""' ..... Date Approved 02/19/2019 ...... .. . ..... Date Revised 02/19/2019�� Summary of Products . . . . ...... .'. ..; FL # Model, Number or Name Description 16730.1 EverGuard TPO Single Ply Roof Thermoplastic polyolefiin sinc Systems Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16730 R19 II 2018 12 1 TPO HVHZ F1_16730-R19.pd1 Approved for use outside HVHZ: No Verified By: Robert Nieminer Impact Resistant: N/A Design Pressure: +N/A/-502.5 Created by Independent Thil Other: 1.) The design pressure herein pertains to one Evaluation Reports system. Refer to ER Appendix for all systems and maximum FL16730 R19 AE 2018 12 TPO HVHZ FL16730-R19.pd1 design pressures. 2.) Refer to ER Section 5 for Limits of Use. Created by Independent Thii Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-18: The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessil Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pu mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contac 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Dep one. The emails provided may be used for official communication with the licensee. However email addresses are public rec address, please provide the Department with an email address which can be made available to the public. To determine if � 2 of 3 4/17/2019, 9:57 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wG... please click here . Product Approval Acoepts: ® ® � check M Credit Card Safe . . .... ...... ...... .... ...... • •Goo • . .... . ..... . •0:00: ..... ....000000......... . . . . 0900% 3 of 3 4/17/2019, 9:57 PM 0 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION GAF Evaluation Report 01506.12.13-1-R20 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 FL16730-1119 Date of Issuance:12/17/2013 Revision 20: 12/17/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition (2017) Florida Building Code, High Velocity Hurricane Zone (HVHZ) sections noted herein. • . . .... ...... DESCRIPTION: EverGuardO TPO Single -Ply Roof Membrane Systems " ' ;"' '. LABELING: Labeling shall be in accordance with the requirements of the Accredited QuZ*##9iSBiUrance Agency noted herein. • • • • • CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) Aanges,'the referencei9:". Quality Assurance documentation changes, or provisions of the Code that relate to the product c6ngea Mceeptance oT• • this Evaluation Report b the named client constitutes agreement to notify Robert Niemin � • • • of an ch • es to the• • p Y g fY erL.P.�E. Y �g product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires 4'c4mplete reviow of this..;. Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaldbled" may De.di$glayedln • advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirefy INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus an 88-page Appendix. Prepared by: Robert l.M.Nieminen, P.E. •• 1,,,.^ :� �?�: The facsimile seal appearing was authorized by Robert '�i d'�'• = %'s`.'c'' �� ' Nieminen, P.E. on 12/17/2018. This does not serve as an Florida Registration No. 59166, Florida DCA ANE1983 ,,�,,,�.,,._ ,... i!"�•�.i "' electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Single Ply Roof Systems Compliance Statement: EverGuard® TPO Single -Ply Roof Membrane Systems, as produced by GAF, have demonstrated compliance with the following sections of the 611 Edition (2017) Florida Building Code, HVHZ through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. • DA Section Property Standard Year TAS 110 Wind, Impact TAS114 2011 TAS 110 Physical Properties TAS 131 1995 Enti Exam Reference Date Kni!iy Exam Reference Date ACRC (TST4671) TAS114 06-035 10/18/2006 FM App (TST1867) FM 4474 797-09635-267 07/16/2014 ACRC (TST4671) TAS114 07-005 01/17/2007 FM App (TST1867) FM 4474 797-09892-267 ZCJIP42014 ACRC (TST4671) TAS114 07-024 03/01/2007 FM App (TST1867) FM 4474 797-10123-283 • 12/17/2014 ACRC (TST4671) TAS114 07-016 04/19/2007 FM App (TST1867) FM 4474 79:-10163-2b7 lf/f912014 ACRC (TST4671) TAS 114 07-017 04/19/2007 FM App (TST1867) FM 4474 7974(P210-267 0 0"15 ACRC (TST4671) TAS 114 07-025 OS/02/2007 FM App (TST1867) FM 4474 7917,iG2U•267 • a 05/2015 ACRC (TST4671) TAS 114 07-026 05/03/2007 FM App (TST1867) FM 4474 791 1%2%-267 02/05/2015 ACRC (TST4671) TAS 114 07-027 05/04/2007 FM App (TST1867) FM 4474 797-RR20011 02/13/2015 ACRC (TST4671) TAS 114 07-042 08/31/2007 FM App (TST1867) FM 4474 111"foe � $41Q7�2�0115 ACRC (TST4671) TAS 114 07-043 09/05/2007 FM App (TST1867) FM 4474 • RR2fi Xo • 04/ 7 2015 ACRC (TST4671) TAS 114 07-045 09/06/2007 FM App (TST1867) FM 4474 30.51441 • • p411542015 ACRC (TST4671) TAS114 07-046 09/06/2007 FM App (TST1867) FM 4474 3047666-LTiR • 06/i4/2p15 ACRC (TST4671) TAS 114 07-048 09/07/2007 FM App (TST1867) FM 4474 RIt d29t3• 11i/112015 ACRC (TST4671) TAS114 07-049 09/10/2007 FM App (TST1867) FM 4474 306MOID • • 01/h4/2016 ACRC (TST4671) TAS114 07-080 01/03/2008 FM App (TST1867) FM 4474 345161 0 02/10�2016 ACRC (TST4671) TAS 114 08-022 04/17/2008 FM App (TST1867) FM 4474 RR204005 • &i/i303016 ACRC (TST4671) TAS114 08-030 04/05/2008 FM App (TST1867) FM 4474 RI!051V • • 05/05/2016 ACRC (TST4671) TAS114 08-023 04/17/2008 FM App (TST1867) FM 4474 RR209192 • • OS/GW2016 ACRC (TST4671) TAS114 08-033 04/19/2008 FM App (TST1867) FM 4474 RR205233 • &J41016 ACRC (TST4671) TAS114 08-032 04/19/2008 FM App (TST1867) FM 4474 RR205946 07/21/2016 ACRC (TST4671) TAS114 11-004 03/21/2011 FM App (TST1867) FM 4474 RR205474 08/31/2016 ACRC (TST4671) TAS114 11-011 03/24/2011 FM App (TST1867) FM 4474 RR206198 09/01/2016 ACRC (TST4671) TAS114 11-012 04/06/2011 FM App (TST1867) FM 4474 RR206353 09/07/2016 ACRC (TST4671) TA5 114 11-013 04/06/2011 FM App (TST1867) FM 4474 RR206620 09/12/2016 ACRC (TST4671) TAS114 11-019 04/08/2011 FM App (TST1867) FM 4474 RR206351 10/21/2016 ACRC (TST4671) TAS114 11-020 04/08/2011 FM App (TST1867) FM 4474 3055491 12/05/2016 ACRC (TST4671) TAS114 11-021 04/11/2011 FM App (TST1867) FM 4474 3058483 12/09/2016 ACRC (TST4671) TAS114 11-040 08/05/2011 FM App (TST1867) FM 4474 3056728 LTR 12/23/2016 ACRC (TST4671) TAS114 11-041 08/05/2011 FM App (TST1867) FM 4470 3056822 LTR 01/04/2017 ACRC (TST4671) TAS114 11-056 09/30/2011 FM App (TST1867) FM 4474 RR208456 02/13/2017 ACRC (TST4671) TAS114 12-008 04/10/2012 FM App (TST1867) FM 4474 3061218 05/10/2017 ACRC (TST4671) TAS114 12-012 04/23/2012 FM App (TST1867) FM 4474 3061218 LTR 05/16/2017 ACRC (TST4671) TAS114 12-013 04/23/2012 FM App (TST1867) FM 4474 RR209927 06/23/2017 ACRC(TST4671) TAS114 12-014 04/23/2012 FM App (TST1867) FM 4474 RR210305 07/13/2017 ACRC (TST4671) TAS114 12-016 04/24/2012 FM App (TST1867) FM 4474 RR212730 04/OS/2018 ACRC (TST4671) TAS114 12-019 04/25/2012 FM App (TST1867) FM 4474 PR449797 04/24/2018 ACRC (TST4671) TAS114 12-024 05/09/2012 FM App (TST1867) FM 4474 RR213333 04/25/2018 ACRC (TST4671) TAS114 12-025 05/09/2012 FM App (TST1867) FM 4474 3056933 07/19/2018 ACRC (TST4671) TAS114 12-029 05/23/2012 FM App (TST1867) FM 4474 3061794 07/25/2018 ACRC (TST4671) TAS114 12-030 05/23/2012 FM App (TST1867) FM 4474 RR215107-267 09/27/2018 ACRC (TST4671) TAS114 11-042-R1 01/27/2012 IRT(TST7408) TAS114 02-008 01/18/2002 ACRC (TST4671) TAS 114 12-033 08/10/2012 IRT(TST7408) TAS 114 03-0728 02/17/2004 ACRC (TST4671) TAS114 12-036 08/13/2012 IRT(TST7408) TAS114 04-012 02/18/2004 ACRC (TST4671) TAS 114 12-018-R1 01/30/2013 IRT(TST7408) TAS114 04-019 04/26/2004 ACRC (TST4671) TAS 114 08-022-R1 01/15/2015 PRI(TST5878) Physicals GAF-373-02-01 10/15/2012 ACRC (TST4671) TA5 114 11-056-R2 01/23/2015 PRI(TST5878) FM 4474 GAF-043-02-03 09/16/2013 ACRC (TST4671) TAS114 16-002 03/04/2016 PRI(TST5878) FM 4474 GAF-043-02-04 09/16/2013 ATI(TST1558) TAS114 H-3320.01-109-44 08/10/2017 PRI(TST5878) Physicals GAF-421-02-01 10/22/2013 ATI(TST1558) TAS114 H-3314.01-109-44 08/14/2017 PRI(TST5878) Physicals GAF-422-02-01 10/22/2013 ATI(TST1558) TAS114 H-3315.01-109A4 08/14/2017 PRI(TST5878) Physicals GAF-424-02-01 11/11/2013 NEMO ETC, LLC Evaluation Report 01506.12.13-1-R2( Certificate of Authorization #32455 6- EDITION (2017) FBC HVHZ EVALUATION FL16730-Rll GAF EverGuard TPO Single Ply Roof Systems Revision 20: 12/17/20V Page 2 of ( ONEMOletc. Enti Exam Reference Date Ent Exam Reference Date ATI(TST3558) TAS114 H-3317.01-109-44 08/14/2017 PRI(TST5878) Physicals GAF-425-02-01 11/11/2013 ATI(TST1558) TAS114 H-3318.01-10944 08/14/2017 PRI (TST5878) Physicals GAF-462-02-02 11/18/2013 ATI (TST1558) TAS114 H-0730.01-109.44 08/16/2017 PRI (TST5878) FM 4474 GAF-457-02-02 01/20/2014 ERD (TST6049) TAS114 SC8580.11.15-4 11/09/2015 PRI (TST5878) FM 4474 GAF-457-02-04 01/24/2014 ERD (TST6049) FM 4474 SC8580.11.15-2 11/18/2015 PRI(TST5878) FM 4474 GAF-457-02-06 01/24/2014 ERD (TST6049) Criticality SC16505.17 09/22/2017 PRI (TST5878) FM 4474 GAF-457-02-07 01/24/2014 ERD(TST6049) FM 4474 SC16825.12.17-1 12/31/2017 PRI (TST5878) FM 4474 GAF-457-02-08 01/24/2014 ERD (TST6049) FM 4474 SC16825.12.17-3B 12/31/2017 PRI(TST5878) Physicals GAF-423-02-01 01/27/2014 F-TEC(TST7393) TAS114 08-050183 06/26/2008 PRI (TST5878) Physicals GAF-426-02-01 01/27/2014 F-TEC(TST7393) TAS114 08-050184 06/26/2008 PRI (TST5878) Rupture GAF-435-02-01 01/29/2014 F-TEC(TST7393) TAS114 08-070133 08/04/2008 PRI (TST5878) FM 4474 GAF-435-02-07 01/29/2014 F-TEC(TST7393) TAS114 08-050185 10/14/2008 PRI (TST5878) FM 4474 GAF-435-02-08 01/29/2014 F-TEC(TST7393) TAS114 08-072805 02/16/2009 PRI (TST5878) FM 4474 GAF-435-02-09 01/29/2014 FM App (TST1867) FM 4470 3003617 12/20/1999 PRI(TST5878) FM 4474 GAF-435-02-10 01/29/2014 FM App (TST1867) FM 4470 3009026 06/18/2002 PRI (TST5878) FM 4474 GAF-435-02-11 01/29/2014 FM App (TST1867) FM 4470 3013861 03/28/2003 PRI (TST5878) FM 4474 GAF-506-02-06 03/06/2014 FM App (TST1867) FM 4470 3014692 08/05/2003 PRI (TST5878) FM 4474 GAF-506-02-08 03/06/2014 FM App (TST1867) FM 4470 3014955 01/22/2004 PRI(TST5878) FM 4474 GAF-S06-02-10 03/06/2014 FM App (TST1867) FM 4470 3012721 02/11/2004 PRI (TST5878) FM 4474 GAF-510-02-02 04/08/2014 FM App (TST1867) FM 4470 3015029 02/19/2004 PRI (TST5878) FM 4474 GAF-510-02-04 04/08/2014 FM App (TST1867) FM 4470 3015578 03/12/2004 PRI (TST5878) FM 4474 GAF-510-02-05 04/08/2014 FM App (TST1867) FM 4470 3020588 03/24/2004 PRI (TST5878) FM 4474 GAF-511-02-02 04/08/2014 FM App (TST1867) FM 4470 3019881 03/20/2004 PRI (TST5878) FM 4474 GAF-506-02-11 04/14/2014 FM App (TST1867) FM 4470 3016068 04/02/2004 PRI (TST5878) FM 4474 GAF-506-02-12 v4 36/A'014 FM App (TST1867) FM 4470 3013861 05/21/2004 PRI(TST5878) FM 4474 GPJ-506-OZ-13 "Val &4 FM App (TST1867) FM 4470 3105578 05/12/2004 PRI (TST5878) FM 4474 GPO-506M2-64 04/14/2014 FM App (TST1867) FM 4470 3014955 01/28/2005 PRI(TST5878) FM 4474 GAF-M-02-e1 04:ft)t814 FM App (TST1867) FM 4470 3022136 03/17/2005 PRI (TST5878) FM 4474 GPOs1"-01 •@Wl*/2014 FM App (TST1867) FM 4470 3020681 09/01/2005 PRI (TST5878) FM 4474 GAJ-•Vj J-J3 05/4/2014 FM App (TST1867) FM 4470 3024051 03/28/2006 PRI(TST5878) FM 4474 GAF-S14-02-04 05/12/2014 FM App (TST1867) FM 4470 797-02093-267 04/26/2006 PRI (TST5878) FM 4474 QVIP4101-95 "VPg14 FM App (TST1867) FM 4470 3023458 07/18/2006 PRI (TST5878) FM 4474 GAF-SP"-07 905/12/2014 FM App (TST1867) FM 4470 3028039 09/11/2006 PRI(TST5878) FM 4474 GP[4V Q8 "121;014 FM App (TST1867) FM 4470 3027159 10/03/2006 PRI (TST5878) FM 4474 GAF-596-02-61 •05/38/2014 FM App (TST1867) FM 4470 3026149 02/05/2007 PRI (TST5878) FM 4474 GAMAI-03 6571372014 FM App (TST1867) FM 4470 3026964 07/25/2007 PRI (TST5878) FM 4474 GAN39"-02 06/06/2014 FM App (TST1867) FM 4470 3028857 11/02/2007 PRI (TST5878) FM 4474 G4-52?02, 2 .06/231JO14 FM App (TST1867) FM 4470 3030199 11/05/2007 PRI (TST5878) FM 4474 GAF-525-02-03 • "381<211114 FM App (TST1867) FM 4470 3030813 11/05/2007 PRI(TST5878) FM 4474 G4-462.01,09 • 07/01/2014 FM App (TST1867) FM 4470 3031262 11/30/2007 PRI (TST5878) FM 4474 GAF14S2-0240 • 07IMP2014 FM App (TST1867) FM 4470 3030292 02/25/2008 PRI(TST5878) FM 4474 GAF-462-02-11 Q j"t14 FM App (TST1867) FM 4470 797-03825-267 07/21/2008 PRI (TST5878) FM 4474 GAF-524-02-02 07/01/2014 FM App (TST1867) FM 4470 3033314 08/26/2008 PRI (TST5878) FM 4474 GAF-524-02-03 07/01/2014 FM App (TST1867) FM 4470 3034749 30/16/2008 PRI (TST5878) FM 4474 GAF-524-02-05 07/01/2014 FM App (TST1867) FM 4470 3032856 11/24/2008 PRI (TST5878) FM 4474 GAF-540-02-02 08/06/2014 FM App (TST1867) FM 4470 3033135 11/24/2008 PRI(TST5878) FM 4474 GAF-540-02-03 08/06/2014 FM App (TST1867) FM 4470 3033862 12/24/2008 PRI(TST5878) FM 4474 GAF-540-02-04 08/06/2014 FM App (TST1867) FM 4470 3034394 02/27/2009 PRI (TST5878) FM 4474 GAF-538-02-02 08/13/2014 FM App (TST1867) FM 4470 3033121 04/13/2009 PRI(TST5878) FM 4474 GAF-538-02-03 08/13/2014 FM App (TST1867) FM 4470 3035300 05/06/2009 PRI (TST5878) FM 4474 GAF-532-02-01 08/22/2014 FM App (TST1867) FM 4470 3036614 06/09/2009 PRI(TST5878) FM 4474 GAF-524-02-05 08/27/2014 FM App (TST1867) FM 4470 3034310 06/15/2009 PRI (TST5878) FM 4474 GAF-549-02-01 08/08/2014 FM App (TST1867) FM 4470 3036141 08/10/2009 PRI (TST5878) FM 4474 GAF-538-02-04 09/02/2014 FM App (TST1867) FM 4470 3037820 04/30/2010 PRI (TST5878) FM 4474 GAF-559-02-11 10/16/2014 FM App (TST1867) FM 4470 797-059797-267 08/18/2010 PRI(TST5878) FM 4474 GAF-559-02-12 10/16/2014 FM App (TST1867) FM 4470 3038215 09/02/2010 PRI(TST5878) FM 4474 GAF-559-02-13 10/16/2014 FM App (TST1867) FM 4470 797-05901-267 10/01/2010 PRI(TST5878) FM 4474 GAF-559-02-14 10/16/2014 FM App (TST1867) FM 4470 797-06003-267 11/11/2010 PRI(TST5878) FM 4474 GAF-559-02-15 10/16/2014 FM App (TST1867) FM 4470 3038318 12/10/2010 PRI (TST5878) FM 4474 GAF-559-02-16 10/16/2014 FM App (TST1867) FM 4470 797-06178-267 02/07/2011 PRI (TST5878) FM 4474 GAF-559-02-18 10/16/2014 FM App (TST1867) FM 4470 3040234 02/23/2011 PRI (TST5878) FM 4474 GAF-538-02-05 12/03/2014 FM App (TST1867) FM 4470 3040377 03/08/2011 PRI (TST5878) Physicals GAF-584-02-01 12/07/2015 FM App (TST1867) FM 4470 3041685 03/24/2011 PRI(TSTS878) Physicals GAF-585-02-01 12/07/2015 FM App (TST1867) FM 4470 797-06254-267 03/24/2011 PRI(TST5878) Physicals GAF-586-02-01 12/07/2015 FM App (TST1867) FM 4470 3041535 06/08/2011 PRI (TST5878) FM 4474 GAF-453-02-05 05/06/2016 FM App (TST1867) FM 4470 797-06537-267 06/13/2011 PRI (TST5878) FM 4474 GAF-453-02-09 05/06/2016 FM App (TST1867) FM 4470 797-06538-267 06/13/2011 PRI (TST5878) Physicals GAF-653-02-01 10/20/2016 FM App (TST1867) FM 4470 3041746 08/17/2011 PRI (TST5878) FM 4474 GAF-653-02-04 10/20/2016 FM App (TST1867) FM 4470 797-06894-267 11/02/2011 PRI (TST5878) FM 4474 GAF-746-02-01 12/14/2016 FM App (TST1867) FM 4470 3038278 11/18/2011 PRI (TST5878) FM 4474 GAF-746-02-02 12/14/2016 FM App (TST1867) FM 4470 3042905 01/10/2012 PRI (TST5878) FM 4474 GAF-746-02-05 12/14/2016 NEMO ETC, LLC Evaluation Report 01506.12.13-1-R20 Certificate of Authorization #32455 6P EDITION (2017) FBC HVHZ EVALUATION FL16730-R39 GAF EverGuard TPO Single Ply Roof Systems Revision 20: 12/17/2018 Page 3 of 6 ONEMOjetc. EatExam Reference Date Eniitf Exam Reference Date FM App (TST1867) FM 4470 797-07041-267 02/27/2012 PRI (TST5878) FM 4474 GAF-746-02-06 12/14/2016 FM App (TST1867) FM 4470 797-07183-267 03/01/2012 PRI (TST5878) FM 4470 GAF-755-02-01 02/02/2017 FM App (TST1867) FM 4470 3044506 03/28/2012 PRI (TST5878) FM 4474 GAF-755-02-02 02/02/2017 FM App (TST1867) FM 4470 797-07331-267 04/13/2012 PRI (TST5878) FM 4474 GAF-755-02-03 02/02/2017 FM App (TST1867) FM 4470 3044862 05/11/2012 PRI (TST5878) FM 4474 GAF-755-02-04 02/02/2017 FM App (TST1867) FM 4470 797-07455-267 05/31/2012 PRI (TST5878) Physicals GAF-700-02-01 03/10/2017 FM App (TST1867) FM 4470 797-07474-267 06/11/2012 PRI (TST5878) FM 4474 GAF-782-02-01 08/24/2017 FM App (TST1867) FM 4470 797-07476-267 06/21/2012 PRI (TST5878) FM 4474 GAF-782-02-02 08/30/2017 FM App (TST1867) FM 4470 3045789 07/12/2012 PRI (TST5878) FM 4474 GAF-776-02-02 10/04/2017 FM App (TST1867) FM 4470 3045863 08/16/2012 PRI (TST5878) Criticality GAF-793-02-01 12/08/2017 FM App (TST1867) FM 4470 3041749 08/23/2012 PRI (TST5878) FM 4474 GAF-793-02-02 12/08/2017 FM App (TST1867) FM 4470 3046328 09/13/2012 PRI(TST5878) FM 4474 GAF-793-02-04 12/08/2017 FM App (TST1867) FM 4470 3041769 09/27/2012 PRI (TST5878) FM 4474 GAF-835-02-02 02/19/2018 FM App (TST1867) FM 4470 797-07744-267 10/17/2012 PRI(TSTS878) FM 4474 GAF-834-02-01 02/28/2018 FM App (TST1867) FM 4470 797-07885-267 11/21/2012 PRI (TST5878) FM 4474 GAF-835-02-03 02/28/2018 FM App (TST1867) FM 4470 3046054 12/21/2012 PRI (TST5878) FM 4474 GAF-835-02-04 02/28/2018 FM App (TST1867) FM 4470 797-08216-267 04/11/2013 PRI(TST5878) FM 4474 GAF-833-02-01 03/02/2018 FM App (TST1867) FM 4470 3048122 04/29/2013 PRI(TSTS878) FM 4474 GAF-833-02-02 03/02/2018 FM App (TST1867) FM 4470 797-08217-267 05/01/2013 PRI(TSTS878) FM 4474 GAF-836-02-01 03/02/2018 FM App (TST1867) FM 4470 797-08264-267 05/23/2013 PRI (TST5878) FM 4474 GAF-836-02-02 03/02/2018 FM App (TST1867) FM 4470 3047237 07/15/2013 PRI(TSTS878) FM 4474 GAF-836-02-03 03/02/2018 FM App (TST1867) FM 4470 3047636 08/08/2013 PRI(TST5878) FM 4474 GAF-836-02-04 40)/02W2018 FM App (TST1867) FM 4474 797-08873-267 11/26/2013 PRI (TST5878) FM 4474 GAF-858- 02-05 • "j7jf018 • • • • • • FM App (TST1867) FM 4474 3048066 12/13/2013 PRI (TST5878) FM 4474 GZF-85&0201 05/01/2018 • FM App (TST1867) FM 4474 3041749 12/30/2013 PRI (TST5878) FM 4474 GAF•8-02lb2 0t/e11�18 ' 85• FM App (TST1867) FM 4474 797-09116-267 01/24/2014 PRI (TST5878) FM 4474 G4F•86860 403 • 69/01/2018 • • • • • • FM App (TST1867) FM 4474 797-09234-267 03/11/2014 PRI (TST5878) FM 4474 G AF--� Jgi0J:4 05/Ql/2018 • • FM App (TST1867) FM 4474 797-09317-267 04/18/2014 PRI (TST5878) FM 4474 GAF-858-02-06 05/01/2018 • • • • • • FM App (TST1867) FM 4474 797-09493-267 05/27/2014 PRI (TST5878) Physicals GAF%"-(1tp1 QVrAV18 FM App (TST1867) FM 4474 797-09495-267 05/27/2014 PRI (TST5878) FM 4474 GAFBa4"-03 • 05/11/2018 • • • • • FM App (TST1867) FM 4474 797-09573-267 06/13/2014 UL,LLC(QUA9625) CIA Sm Confirm; IN, PAJX, UT j2d1742018 00000 FM App (TST1867) FM 4474 797-09497-267 06/23/2014 • • • • • FM App (TST1867) FM 4474 797-09594-267 06/24/2014 • • " �' ' 0 9 • • • • • PRODUCT4. • 00 4.1 This Evaluation Report covers EverGuard® TPO Single -Ply Roof Membrane Systems in6talled in accordance with • • • •; GAF published installation instructions and the Limitations / Conditions of Use herein. • • • • • • • ' • • • 4.1.1 EverGuard` TPO membranes are nominal 45-mil (1.1 mm), 60-mil (1.52-mm) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic polyolefin roof covers supplied. Side and end laps are sealed using hot air welding. The roof cover is mechanically attached or fully -adhered to Approved substrates. 4.1.2 EverGuard Extreme TPO membranes are nominal 50-mil (1.27-mm), 60-mil (1.52-mm), 70-mil (1.8) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic polyolefin roof covers supplied. Side and end laps are sealed using hot air welding. The roof cover is mechanically attached or fully -adhered to Approved substrates. 4.1.3 EverGuard* TPO FB Ultra membranes are nominal 45-mil (1.1 mm), 60-mil (1.52-mm) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic (TPO) roof covers with a polyester fleece backing. Side and end laps are sealed using hot air welding. The roof cover is mechanically attached or fully -adhered to Approved substrates. 4.1.4 EverGuard Extreme TPO FB Ultra membranes are nominal 50-mil (1.27-mm), 60-mil (1.52-mm), 70-mil (1.8) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic (TPO) roof covers with a polyester fleece backing. Side and end laps are sealed using hot air welding. The roof cover is mechanically attached or fully -adhered to Approved substrates. 4.1.5 EverGuard' Freedom' TPO HW and EverGuard® FreedomTm TPO with RapidlSeam"Technology membranes are nominal 45-mil (1.1 mm) or 60-mil (1.52-mm) thick, internally reinforced thermoplastic (TPO) roof covers with a self -adhering backing. EverGuard® Freedom'" TPO HW laps are sealed using hot air welding. EverGuard® Freedom'" TPO with RapidSeam'" Technology laps are self -adhering. The roof cover is self -adhered to Approved substrates. NEMO ETC, LLC Evaluation Report 01506.12.13-1-R20 Certificate of Authorization #32455 6TN EDITION (2017) FBC HVHZ EVALUATION F1.16730-1119 GAF EverGuard TPO Single Ply Roof Systems Revision 20: 12/17/2018 Page 4 of 6 ONEMOletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 Fire classification is not part of this Evaluation Report; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.4 The evaluation herein pertains to above -deck roof components; deck -attachment details pertain to 'as -tested' conditions under Testing Application Standard TAS 114, Appendix J. Roof decks shall be in accordance with FBC (HVHZ) requirements to the satisfaction of the Authority Having Jurisdiction. 5.5 Fastener spacing for mechanical attachment of anchor/base sheet or membrane is based on a minimum fastener resistance value in conjunction with the maximum design pressure (MDP) listed for a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing — prepared, signed and sealed by a qualified design professional — may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standard TQS 10,� and cdlWijtjdns in compliance with Roofing Application Standard RAS 117 or Roofing Application Stanclaft BAS137. .... 5.5.1 If mechanical attachment to the structural deck through lightweight insulating conemp ois prophSe-d, field withdrawal resistance testing shall be performed to confirm equivalent or determine enh3M&Vfastening l3atterns and density. All testing and fastening design shall be in compliance with Testing ApplAMWN.Standawi"US 105 and Roofing Application Standard RAS 117 and/or Roofing Application Standard RAS 131.' Calculations shall be prepared, signed and sealed by a qualified design professional. • : • • • • 5.6 For systems where specific lightweight insulating concrete is referenced, consult the.6tar;ant HVHZ product approval documentation for specific deck construction and limitations. For systems vihere sj ecificslightvveight insulating concrete is not referenced, the minimum design mix shall be for minimum 300 psi oellular material. 5.7 For recover installations, the existing roof shall be examined in accordance with FBC 15;f . • • 5.8 Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased, as calculated in compliance with Roofing Application Standard RAS 117 and/or Roofing Application Standard RAS 137 by a qualified design professional. *This extrapolation is not permitted for systems marked with an asterisk*. 5.9 All attachment and sizing of perimeter nailers, metal profile and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 5.10 For assemblies marked with an asterisk*, the maximum design pressure (MDP) limitation listed shall be applicable to all roof pressure zones (i.e., field, perimeters and corners). Neither rational analysis, nor extrapolation is permitted for enhanced attachment at enhanced pressure zones (i.e., perimeters, corners and extended corners). 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with Testing Application Standard TAS 124. 5.12 All products listed herein shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. NEMO ETC, LLC Evaluation Report 01506.12.13-1-R20 Certificate of Authorization #32455 6- EDITION (2017) FBC HVHZ EVALUATION FL16730-R19 GAF EverGuard TPO Single Ply Roof Systems Revision 20: 12/17/2018 Page 5 of 6 ONEMOletc. 6.1 EverGuard® TPO Single -Ply Roof Membrane Systems shall be installed in accordance with GAF published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per Testing Application Standard TAS 114 has already been applied). Refer to FBC 1620 and Roofing Application Standard RAS 128 for determination of design wind loads. 6.3 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. UL, LLC—QUA9625; (847) 664-3281; k.chancellor@ul.com - THE 88-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - •••• • • •• • ..•• • • • .••.•• *go** •.••.• . • .. • . • . .. • . • ... • • • . . • • . • •••• NEMO ETC, LLC Evaluation Report 01506.12.13-1-R20 Certificate of Authorization N32455 6T' EDITION (2017) FBC HVHZ EVALUATION FL16730-1119 GAF EverGuard TPO Single Ply Roof Systems Revision 20: 12/17/2018 Page 6 of 6 TABLE DECK APPLICATION TYPE DESCRIPTION ONEMOletc. PAGE 1A Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-7 1B Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 8-9 1C Wood New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 1D Wood New, Reroof (Tear -Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 10-11 1E Wood New, Reroof (Tear -Off) or Recover C-2 Plate -Bonded Roof Cover 12 1F Wood New, Reroof (Tear -Off) or Recover D-1 Insulated, Mechanically Attached Roof Cover 12 1G Wood New, Reroof (Tear -Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 13 1H Wood New, Reroof (Tear -Off) or Recover E-1 Non -Insulated, Mechanically Attached Roof Cover 13 11 Wood New, Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 14-16 2A Steel New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 17 26 Steel or Structural concrete New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 17-21 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Base and Cap Ply 22 2D Steel or Structural concrete New, Reroof (Tear -Off) or Recover B-2 Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 23-26 2E Steel or Structural concrete New, Reroof (Tear -Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 26-35 2F Steel or Structural concrete New, Reroof (Tear -Off) or Recover C-1 Mechanically Attached Insulation, Bonded Base and Cap Ply 36 2G Steel or Structural concrete New, Reroof (Tear -Off) or Recover C-1A Thermal Barrier with Vapor Barrier, Mechanically Attached Insulation, Bonded Roof Cover 37-41 2H Steel or Structural concrete New, Reroof (Tear -Off) or Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 42-43 21 Steel or Structural concrete New, Reroof (Tear -Off) or Recover D-1 Insulated, Mechanically Attached Roof Cover 44-46 2.1 Steel or Structural concrete New, Reroof (Tear -Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 46 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47-55 3B Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Base and Cap Ply 55 3B Structural concrete New, Reroof (Tear -Off) or Recover F Non -Insulated, Bonded Roof Cover 55 4A Lightweight concrete New or Reroof (Tear -Off) A-1 LWC to Deck, Bonded Insulation, Bonded Roof Cover 56-57 4B Lightweight concrete New or Reroof (Tear -Off) A-2 LWC to Deck, Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 58 4C Lightweight concrete New, Reroof (Tear -Off) or Recover C-2 LWC to Deck, Through -attached Plate -Bonded Roof Cover 59 4D Lightweight concrete New, Reroof (Tear -Off) or Recover D-1 LWC to Deck, Through -attached Mechanically Attached Roof Cover 59-60 4E Lightweight concrete New or Reroof (Tear Off) E LWC to Deck, Mechanically Attached Base Sheet, Bonded Roof Cover 60-61 4F Lightweight concrete New or Reroof (Tear Off) F LWC to Deck, Bonded Roof Cover 62-63 4G Lightweight concrete New or Reroof (Tear Off) F Temp Roof / Vapor Barrier to Deck, LWC to Temp Roof / Vapor Barrier, Bonded Roof Cover 63-64 SA Cementitious wood fiber New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 65 5B Cementitious wood fiber New, Reroof (Tear -Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 66 5C Cementitious wood fiber New, Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 66 SO Cementious wood fiber New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 66 6A Existing gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 67-68 6B Existing gypsum Reroof (Tear -Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 68 6C Existing gypsum Reroof (Tear -Off) B-1 ech. chid Boseinsrlation,Borded Top Insulation, Bonded Roof Cover 69-71 6D Existing gypsum Reroof (Tear -Off) C-1 !V echaniil;41ly AjtgheD I ul iprl Borgled Roof Cover 71-72 6E Existing gypsum Reroof (Tear -Off) E-2 Now-Insulalted!MLchahictllytttichV ese Sheet, Bonded Roof Cover 72 6F Existing gypsum Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 72 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 73-86 7B Wood or Steel Recover C-2 Plaje:Bpnded Roof Cgyor, • Y 87 7C Steel Recover D-1 • Insulated, Medharlical"Attache?Ro f v 88 7D Various Recover F • jlon- sulaied,9onded�oofiovr • • • 88 NEMO ETC, LLC Evaluation Report 01506.12.13-1-R20 for FL16730-R19 Certificate of Authorization #32455 6eh EDITION4Vl7) IBC HVIIZ EyVAyUArTWM • • Revision 20: 12/17/2018 Prepared by: Robert Nieminen, PE-59166 EverGuard TPO Single -Ply Roof Membrrne2jjems,-(800i766-3V1 Appendix 1, Page 1 of 88 ••• • • • ••• • • ONEMOletc. The following notes apply to the systems outlined herein: 1. The evaluation herein pertains to above -deck roof components; deck -attachment details pertain to 'as -tested' conditions under Testing Application Standard TAS 114, Appendix J. Roof decks shall be in accordance with FBC (HVHZ) requirements to the satisfaction of the Authority Having Jurisdiction. 2. Unless otherwise noted, fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 35 or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3" Metal Plate. Min. 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only). Minimum 0.75-inch steel penetration, engage the top flute of the steel deck. ➢ Structural concrete: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3" Metal Plate. Minimum 1.25-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral wool roof board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC (HVHZ) 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Refer to GAF published installation instructions for details and requirements regarding the use of FBC HVHZ approved polystyrene insulation in EverGuard• roofing systems: INSULATION: HIGH TRAFFIC APPLICATIONS: RECOVER APPLICATIONS: ➢ FBC HVHZ approved Expanded polystyrene (EPS) meeting or ➢ FBC HVHZ approved Extruded polystyrene (XPS) meeting or ➢ FBC HVHZ approved XPS Fan -Fold Recover Board with plastic exceeding Testing Application Standard TAS 110 and ASTM C578, exceeding Testing Application Standard TAS 110 and ASTM C578, facer meeting or exceeding Testing Application Standard TAS 110 Type IX, nominal 1.8 Ib/ft2 density and minimum 25 psi Type IV, minimum 1-inch thick and minimum 25 psi compressive and ASTM C578, Type IV, 3/8-inch thick and minimum 25 psi compressive strength. FBC HVHZ approved Expanded polystyrene (EPS) with plastic facer meeting or exceeding Testing Application Standard TAS 110 and ASTM C578, Type IX, nominal 1.8lb/ft2 density and minimum 25 psi compressive strength. strength. FBC HVHZ approved Expanded polystyrene (EPS) with plastic facer meeting or exceeding Testing Application Standard TAS 110 and ASTM C578, Type IX, minimum 1-inch thick and minimum 25 psi compressive strength. compressive strength. ➢ FBC HVHZ approved EPS Recover Board meeting or exceeding Testing Application Standard TAS 110 and ASTM C578, Type IX, 1/2-inch thick and minimum 25 psi compressive strength. ➢ FBC HVHZ approved EPS Recover Board with plastic facer meeting or exceeding Testing Application Standard TAS 110 and ASTM C578, Type IX, 1/2-inch thick and minimum 25 psi compressive strength. FireOut- Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck Protection or VersaShield• SOIOT" Fire -Resistant Slip Sheet, installed in accordance with GAF published installation instructions and fire resistance certification listings, may be used as a non -load -bearing, fire -barrier / slip -sheet component within any system outlined herein. 4. If mechanical attachment to the structural deck through lightweight insulating concrete is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137. Calculations shall be prepared, signed and sealed by a qualified design professional. 5. Preliminary insulation attachment for System Type C-2 and D = Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead gvidth is atthN•tir;e of applicaton; jlle ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot Asphalt (HA): Full mopping, 25-30 Ibs/square. • . • • • • • • • • • ➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): Continuous 2.5 to 3.5-inch ribbons, 12-inch p e • • • • • • • • ➢ LRF Adhesive M (LRF-M): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. • • • • • • • • ➢ OlyBond Adhesive Fastener (Classic): Full coverage, 1 gal/square. ➢ OlyBond 500 (013500): Continuous 0.75 to 1-inch wide ribbons, Wn4,p p. using gace�aN SpotSrot or Canister delivery methods. Note: OlyBond Classic orOlyBond 500 Green may be used in place of OB500 when used to bond inty(ation Qr coverf� acts. • • • • • ➢ Note: When multiple loyers(s) of insulation and/or coverboard are installed in ribboB-a pliecOadhesive,•board points shs*lft; stag&red. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shalrbe not 14? than one•7oly �* specified ribbons spacing. NEMO ETC, LLC Evaluation Report 01506.12.13-1-R20 for F1.36730-1139 Certificate of Authorization #32455 61h EDITW2017) FBOHMHZ [VALYATIOIN • Revision 20: 12/17/2018 Prepared by: Robert Nieminen, PE-59166 EverGuard TPO Single4Ply Rlof Me;ib&Od.*Systjms; 0100) 7ji-3411 Appendix 1, Page 2 of 88 • • • • • • • • • • • •• •• • • • •• •• 000 0 0 0 ••• 0 0 ONEMOletc. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table. ➢ Hot Asphalt (HA): MDP = -240.0 psf (Min. 0.5-inch thick) ➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP = -117.5 psf ➢ LRF Adhesive M (LRF-M): MDP = -232.5 psf ➢ OlyBond 500 (OB500): MDP = -315.0 psf ➢ OlyBond 500 (OB500): MDP = -487.5 psf ➢ OlyBond 500 (OB500): MDP = -292.5 psf 8. Bonded polyisocya n u rate insulation boards shall be maximum 4 x 4 ft. (Min. 1.0-inch thick) (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation) (Min. 0.5-inch thick EnergyGuard RH or RN) (Min. 0.5-inch thick EnergyGuard RA) (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation) 9. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased, as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137 by a qualified design professional. *This extrapolation is not permitted for systems marked with an asterisk*. 10. For assemblies marked with an asterisk*, the maximum design pressure (MDP) limitation listed shall be applicable to all roof pressure zones (i.e., field, perimeters and corners). Neither rational analysis, nor extrapolation is permitted for enhanced attachment at enhanced pressure zones (i.e., perimeters, corners and extended corners). 11. Fastener spacing for mechanical attachment is based on a minimum fastener resistance value in conjunction with the maximum design pressure (MDP) listed for a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing - prepared, signed and sealed by a qualified design professional - may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standard TAS 105 and calculations in compliance with Roofing Application Standard RAS 117 or RAS 137. 12. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with Testing Application Standard TAS 124. 13. For System Type D, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For recover installations, the existing roof shall be examined in accordance with FBC 1521. For Recover Applications using System Type C-2 or or any System Type D, the insulation is optional. Alternatively, a separator board may be installed prior to roof cover installation when using System Type C-2 or any System Type D or a separator sheet may be installed prior to roof cover installation when using any System Type D. The separator component shall be documented as meeting FBC (HVHZ) 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. ➢ Separator Board Options for Recover System Type C-2 or System Type D: Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation, Structodeck High Density Fiberboard Roof Insulation, EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard NH HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation or EnergyGuard NH HD Plus Polyiso Insulation or min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass - Mat Roof Board. ➢ Separator Sheet Options for Recover System Type D: EverGuard Polymat Separation Layer (3 oz/yd') or EverGuard Polymat Cushioning Layer (6 oz/yd'). 15. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC NOA or HVHZ Product Approval for specific deck construction and limitations. For systems where speiifir l." iLncg refgencgd, jhe gtgimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2- inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point:. For "pit-eligtInt• LWC Pefetentes, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary addRiyes, iR accordancowith pnoedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted, use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designertor Recoz dlutgwly Javw ang 44ildiction. 16. For adhesive -applied membrane systems, side laps shall be minimum 3-inch wide sealed with min. 1.5-inch heat weld. Unless otherwise noted, membrane adhesive application rates are as follows: MEMBRANE ADHESIVE MEWHOD • • • • • • • • • RATE EverGuard TPO EverGuard TPO #1121 Bonding Adhesive • • • • 4 V 1.CWI/Au&e/$u*cC For use over SECUROCK Gypsum -Fiber Roof Board, the application rate Contact (both sides) changes tU 1.2 to 1.6Tgal/tq/surface (#1121) NEMO ETC, LLC Certificate of Authorization #32455 Prepared by: Robert Nieminen, PE-59166 6" EDITR$120}7) FBC`HV=IZ eVA1L8ffION • EverGuard TPO SingleAPly Roof Menbseea*,5ystams; �00) 74-3411 • • • • • • • • • • • •• •• • • • •• •• ••• 0 0 0 ••• 0 0 Evaluation Report 01506.12.13-1-R20 for FL36730-R39 Revision 20: 12/17/2018 Appendix 1, Page 3 of 88 ONEMO I etc. GAP ..COMBINATIONS MEMBRANE ADHESIVE METHOD RATE To polyisocyanurate or Structodek High Density Fiberboard Roof Insulation, Fiber Base HDl or Fiber Base HD6 EverGuard TPO EverGuard WB181 Bonding Adhesive (WB181) Contact (both sides) at 0.63 gal/square and roof cover underside at 0.21 gal/square. To Dens Deck Prime or SECUROCK Gypsum - Fiber Roof Board at 0.63 to 0.75 gal/square and roof cover underside at 0.21 to 0.25 gal/square EverGuard TPO EverGuard Low VOC TPO Bonding Adhesive (L- Contact (both sides) 0.46 gal/square/surface VOCEverGuard TPO EverGuard TPO 3 Square Low VOC Bonding Contact (both sides) 0.84 gal/square/surface Adhesive (TPO 3-Square) EverGuard TPO FB Ultra Hot asphalt Wet lay (substrate) 25 Ibs/square EverGuard TPO FB Ultra EverGuard WB181 Bonding Adhesive (WB181) Wet lay (substrate) 0.83 to 1.0 gal/square GAF LRF Adhesive M (LRF-M) or LRF Adhesive 1-inch wide ribbons spaced as noted in tables herein. Note: The adhesive ribbons are located directly over EverGuard TPO FB Ultra 0 (LRF-O) Wet lay (substrate) the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. EverGuard TPO FB Ultra GAF 2-Part Roofing Adhesive (GAF 2-Part) Wet lay (substrate) "Spatter pattern" at 3.75 Ibs/sq. EverGuard TPO FB Ultra OlyBond 500 Wet lay (substrate) "Spatter pattern" at 0.32 gal/square. 17. Vapor barrier options for over structural concrete deck with adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A applies: VAPOR BARRIER OPTIONS; OPTION PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE ATTACH VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS FlexPly 6 Hot asphalt applied Hot asphalt -360.0 VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch -applied GAF 2-Part, 12-inch o.c. -169.0 VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch -applied GAF 2-Part, 12-inch o.c. -180.0 VB-4. GAF SA Primer GAF SA Vapor Retarder Self -adhering GAF 2-Part, 12-inch o.c. -202.5 VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self -Adhering Cap Sheet Self -adhering GAF 2-Part, 12-inch o.c. -250.0 VB-6. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS FlexPly 6 Hot asphalt applied GAF 2-Part, 12-inch o.c. -262.5 VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied GAF 2-Part, 12-inch o.c. -270.0 VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch -applied LRF-M, 12-inch o.c. -180.0 VB-9. GAF SA Primer GAF SA Vapor Retarder Self -adhering LRF-M, 12-inch o.c. -202.5 VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS FlexPly 6 Hot asphalt applied LRF-M, 12-inch o.c. -495.0 VB-11. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch -applied OlyBond 500, 12-inch o.c. -165.0 VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Srhodl:IT • • • • • • • • Torch -applied OlyBond 500, 12-inch o.c. -180.0 VB-13. Matrix 307 Premium Asphalt Primer or ASTM D41 primer • • • • • • • • • Ruberoid 20 Smooth • • • • • • • • • • • • • • • • • • • Matrix 102 SBS Membrane Adhesive at 1.5 gal/square OlyBond 500, 12-inch o.c. -202.5 VB-14. GAF SA Primer GAF SA Vapor Retarder • • • • • Self -adhering OlyBond 500, 12-inch o.c. -202.5 VB-15. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch -applied OlyBond 500, 12-inch o.c. -232.5 VB-16. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two p{ia6, COLAS #7y8ase pet, TrLPIy #750 ase Sheet, GAF S Ply , Tri-PIV•PI^ orSAFGLA9 FlexPy 69 Hot asphalt applied OlyBond 500, 12-inch o.c. 352.5 18. Side laps for EverGuard Freedom TPO with RapidSeam Technology are self -adhering. Sidi Wos fo MerGutrd freedom TPO H%ar• heat welded. Unless otherwise noted, reference to EverGuard Freedom TPO in this Appendix relates to either method. • • NEMO ETC, LLC Certificate of Authorization #32455 Prepared by: Robert Nieminen, PE-59166 6" EDITIt7'N•(20i7) FBOHVIIZ IiVALW4TIQN • EverGuard TPO Single3lly Rpof Mepib6@CSystjms; (P00) 70-3411 • • • • • • • • • • • •• •• • • • •• •• ••• 0 0 0 000 0 0 Evaluation Report 01506.12.13-1-R20 for FL16730-1119 Revision 20: 12/17/2018 Appendix 1, Page 4 of 88 ONEMO I etc. 19. The "Triposite Roofing System' noted herein consists of loose -laid GAFGLAS Stratavent Perforated Venting Base Sheet, followed by asphalt -applied two (2) plies of Ruberoid 20 Smooth or three (3) plies of GAFGLAS FlexPly 6, followed by asphalt -applied 80-mil EverGuard TPO FB Ultra with 1-5/8" heat welded side laps. 20. Unless otherwise noted, the "Hybrid Roofing System' noted herein consists of asphalt -applied Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet or GAFGLAS #80 Ultima Base Sheet followed by asphalt -applied EverGuard TPO FB Ultra. 21. EverGuard Extreme TPO may be used as an alternate to EverGuard TPO. EverGuard Extreme TPO FB Ultra may be used as an alternate to EverGuard TPO FB Ultra. 22, The following insulations are interchangeable within the scope of this Evaluation Report: ➢ EnergyGuard Polyiso Insulation b EnergyGuard NH Polyiso Insulation; ➢ EnergyGuard Ultra Polyiso Insulation b EnergyGuard NH Ultra Polyiso Insulation; ➢ EnergyGuard HD Polyiso Insulation b EnergyGuard NH HD Polyiso Insulation; ➢ EnergyGuard HD Plus Polyiso Insulation EnergyGuard NH HD Plus Polyiso Insulation 23. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC (HVHZ) 1620 and RAS 128 for determination of design wind loads. TABLE 1A: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 16) MDP Type Fasteners Attach Type Attach Type Attach Base Ply Cap No. (Note1) (Psf) Min. 15/32- GAFGLAS #75 Base Sheet, 32 ga., 1-5/8- Min. 1-inch EnergyGuard High Density Fiberboard Min. 0.5-inch Structodek EverGuard TPO FB inch plywood 7ri•Ply #75 Base Sheet, inch dia. tin 8-inch o.c. at min. 4- Polyiso Insulation, Roof Insulation or One or two plies Ruberoid 20 Ultra in hot or wood GAFGLAS #80 Ultima Base caps with 12 inch laps and 8-inch EnergyGuard Ultra Polyiso EnergyGuard Perlite Smooth, Ruberoid Mop Smooth, asphalt or GAF 2- W-1. plank; 24" Sheet, GAFGLAS ga. annular ocin twoequally o.c. , Insulation or EnergyGuard HA Recover Board or Min. HA Ruberoid Mop Smooth 1.5 or Part (spatter) or 45.0 spans; 8d Stratavent Nailable ring shank spaced, staggered RH Polyiso or min. 1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus Smooth in OlyBond 500 ring shank Venting Base Sheet, nails center rows inch EnergyGuard RA or Perlite Roof Insulation hot asphalt (spatter) nails 6" o.c. Ruberoid 20 Smooth EnergyGuard RN (homogeneous) Min. 15/32- GAFGLAS #75 Base Sheet, 32 ga., 1-5/8- Min. 1-inch EnergyGuard One or two plies Ruberoid 20 EverGuard TPO FB inch plywood Tri-Ply #75 Base Sheet, inch dia. tin 8-inch o.c. at min. 4- Polyiso Insulation, Min. 0.25-inch Dens SmoothRuberoid Mop Smooth , , Ultra in hot or wood GAFGLAS #80 Ultima Base caps with 12 inch laps and 8-inch EnergyGuard Ultra Polyiso Deck Prime or Ruberoid Mop Smooth 1.5 or asphalt or GAF 2- W-2. plank; 24" Sheet, GAFGLAS ga. annular o.c. in two, equally Insulation or EnergyGuard HA SECUROCK Gypsum- HA Ruberoid Mop Plus Smooth in Part (spatter) or _45.0 spans; 8d Stratavent Nailable ring shank spaced, staggered RH Polyiso or min. 1.5- Fiber Roof Board hot asphalt or Ruberoid HW 25 OlyBond 500 ring shank Venting Base Sheet, nails center rows inch EnergyGuard RA or Smooth or Ruberoid HW (spatter) nails 6" o.c. Ruberoid 20 Smooth EnergyGuard RN Smooth, torch -applied Min. 19/32- Min. 1-inch EnergyGuard Min. 0.5-inch Structodek inch plywood GAFGLAS #80 Ultima Base 32 ga., 1-5/8- 9-inch o.c. at min. 4- Polyiso Insulation, High Density Fiberboard One or two plies Ruberoid 20 EverGuard TPO FB or wood Sheet, GAFGLAS inch dia. tin inch laps and 9-inch EnergyG��rd �Itra Po�iso Roof Insulation or Smooth, Ruberoid Mop Smooth, Ultra in hot W-3. plank; 24" Stratavent Nailable caps with 12 o.c. in two, equally • • Insulation or EnergyGliarrc JIX • • •Ener6yruard Perlite HA Ruberoid Mop Smooth 1.5 or asphalt or GAF 2- -45.0 spans; 8d Venting Base Sheet, ga. annular spaced, staggered RH Po(I/o or m�!1.5- • • • • • • • • • •Retbver Board or Min. EnergyGuard Ruberoid Mop Plus Smooth in p Part (spatter) or OlyBond 500 ring shank Ruberoid 20 Smooth ring shank nails center rows • inch EnerayGuardR4 or • • • • • • • •O.��jnch • Perlite�toof Insulation hot asphalt (spatter) nails 6" o.c. EnerglAard RIQ • • • • • •(homogeneous) •• ••• • ••• • • •• • • • • ••• • • • • • • • • • • • • • • • •• • • •• • • • NEMO ETC, LLC Evaluation Report 01506.12.13-1-R20 for FL36730-R19 Certificate of Authorization #32455 61h EDITf*120:7) FB(:H jZ gvAtjmngN • Revision 20: 12/17/2018 Prepared by: Robert Nieminen, PE-59166 EverGuard TPO Single2lly Roof Mew baa (PSyst•ms; 40 ) 76-3411 Appendix 1, Page 5 of 88 • •• •• • • • •• •• ••• 0 0 0 000 0 0 ONEMOletc. System Deck Insulation Layer(s) (Note 14) Base or Anchor Sheet Roof Cover MDP (psf) Base Fasteners Attach No. (Note 1) Type Attach Min. 19/32-inch plywood; 24" spans; One or more layers, GAF StormSafe Anchor Drill-Tec #14 Fastener with Drill- 18-inch o.c. at min. 4-inch lap EverGuard Freedom W-53. 8d ring shank nails, 6" o.c. at edges any combination Loose -laid Sheet (Max. 48-inch Tec 3" Steel Plate or Drill-Tec 3 and 18-inch o.c. at two, equally TPO / self adhered -45.0 * and 6" o.c. at intermediate supports wide) in. Ribbed Galvalume Plate (Flat) spaced, staggered center rows Min. 19/32-inch plywood; 24" spans; One more layers, GAF StormSafe Anchor Drill-Tec #14 Fastener with Drill- 8-inch o.c. at min. 4-inch lap and EverGuard Freedom W-54. 8d ring shank nails, 6" o.c. at edges combination any co Loose -laid Sheet (Max. 48-inch Tec 3 in. Ribbed Galvalume Plate 8-inch o.c. at two, equally TPO /self adhered -60.0* and 6" o.c. at intermediate supports wide) (Flat) spaced, staggered center rows System Deck Roof Cover MDP No. (Note 1) Membrane Fasteners Attachment (psf) Min. 19/32-inch plywood or wood plank; 6-inch o.c. within 5.5-inch wide laps spaced 114.5-inch o.c. and W-55. ____. o, ______ __„_ _ _ EverGuard TPO Drill-Tec #14 Fastener with Drill-Tec 2 in. Double Barbed XHD Plates 1 -.._,..,, 1— , — ,_,,, , -45.0 W-56. Min. 19/32-inch plywood or wood plank; 24" spans; 8d common nails 6" o.c. EverGuard TPO �DrillTec Fastener with Drill-Tec 2 in. Double Barbed XHD Plates 6-inch o.c. within 5-inch wide laps spaced 55-inch o.c. and sealed with a 1.75-inch heat weld. 52.5 iz-incn o.c. wanin o-mcn wine laps spaces vo-mcn o.c. lover W-57. (existing) plywood or wood plank; 24" EverGuard TPO fastened through deck to engage wood joists, minimum 1-inch wood joists) and sealed with a 1.5-inch heat weld. -60.0 spans; 8d ring shank nails 6" o.c. emedement Min. 19/32-inch (new) or min. 15/32-inch Drill-Tec #14 Fastener with Drill-Tec 2-3/4 in. Barbed SXHD Plates 12-inch o.c. within 6-inch wide laps spaced 48-inch o.c. (over W-58. (existing) plywood or wood plank; 24" EverGuard TPO fastened through deck to engage wood joists, minimum 1-inch wood joists) and sealed with a 1.5-inch heat weld. -75.0 spans: 8d rine shank nails 6" o.c. emedement • •• • • • • ••• • •• ••• •• • • • •• •• ••• • ••• • • • • • • • • • • • • • • • •• • • •• • • • NEMO ETC, LLC Evaluation Report 01506.12.13-1-R20 for FL36730-R39 Certificate of Authorization #32455 611 EDITf"247) FB JHVSiZ rVAL19ATIONd • Revision 20: 12/17/2018 Prepared by: Robert Nieminen, PE-59166 EverGuard TPO Single4ly Rrof Memb•aaa,Syst•ms; 4100) 70-3411 Appendix 1, Page 13 of 88 • • • • • • • • • • • • • • • • • • • • • • a•• 0 • 0 ••• • 0 ROCIFING SYSTEMS I UL Product iQ https://iq.ulprospector.com/en/profile?e=148955 5. Deck: C-15/32 Incline: 1/2 Primer: —"TOPCOAT® FireOut" Fire Barrier Coating" or "FireOut' Fire Barrier Coating", applied at a rate of 1-gal./100-ft.2. Base Sheet (Optional): — One ply Type G2 "GAFGLAS® *75 Base Sheet" or "Tri-Ply® #75 Base Sheet' or "GAFGLAS® #80 Ultima' Base Sheet' or "GAFGLAS® Stratavent® Nailable Venting Base Sheet', mechanically fastened. Slip Sheet (Optional): — One ply "VersaShield® SoloTM' Fire Resistant Slipsheet, mechanically fastened. Membrane: — "EverGuard® TPO" 45-mil to 80-mil or "EverGuard Extreme® TPO" 50-mil to 80-mil, mechanically fastened. 6. Deck: NC Incline: 1/2 Barrier Board (Optional): — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard— Roofboard" or minimum 1/2-in. thick gypsum wallboard or United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX), mechanically fastened. Slip Sheet (Optional): — One ply "VersaShield ® Fire -Resistant Roof Deck Protection", mechanically fastened. Base Sheet (Optional): — One ply Type 15 or Type 30 or Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6" or Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultimal Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet' or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Membrane: — "EverGuard® TPO" 45-mil to 80-mil or "EverGuard Extreme® TPO" 50-mil to 80-mil or "EverGuard® TPO FB Ultra" 45-mil to 80-mil or "EverGuard Extreme® TPO FB Ultra" 50-mil to 80-mil, mechanically fastened. Surfacing: — United Solar Ovonics Field -Assembled Photovoltaic (Solar) Module Systems "PVL-29, -31, -58, -60, -62, -64, -68, -87, -93, -116, -120, -124, -128, -136", self -adhered. 7. Deck: C-15/32 Incline: 1/2 0000 ,Slip Sheet: — Two plies "VersaShield ® Fire -Resistant Roof Deck Protection" or one ply "VersaShield ® Sdol Fj a Resistart• • 0 • • • • Slipsheet",mechanically fastened. •• • .... • Membrane: — "EverGuard ® TPO FB Ultra" 45-mil to 80-mil or "EverGuard Extreme® TPO FB Ultra" 50-nNlobo•80.mil, me"pically •• • • •• fastened. • • • • • • • • • 8. Deck: C-15/32 Incline: 1/2 • • • • • Slip Sheet: — Two plies "VersaShield® Fire -Resistant Roof Deck Protection" or one ply "VersaShield(g) Sol llirie ResistpAf. .', • • • • • • •• •• ••••• Slipsheet", mechanically fastened. •• • • • • +• •. Insulation: — "EnergyGuardl" or "EnergyGuardTM' NH" or "EnergyGuardTM' RF" or "EnergyGuard- Ultra,"br " RnqgyGuarcl " NH '. Ultra" or "EnergyGuard— RA" or "EnergyGuard— RN" or "EnergyGuard— RW or "EnergyGuarcl " RM", any thickness or a;p FIE: • •' ••" Classified wood fiber, mechanically fastened. '..' ; •� �•+••� Cover Board (Optional): — 1/2-in. thick "EnergyGuard' HD" or 1/2-in. thick "EnergyGuardTM HD Plus" or "EnergyGuard ,%Fj PID" or "EnergyGuarcl ' NH HD Plus", mechanically fastened. Membrane: — "EverGuard® TPO" 45-mil to 80-mil or "EverGuard Extreme® TPO" 50-mil to 80-mil, mechanically fastened. 9. Deck: C-15/32 Incline: 3/4 Slip Sheet: — Two plies "VersaShield ® SoloTM' Fire Resistant Slipsheet', mechanically fastened. Insulation: — "EnergyGuardTM"' or "EnergyGuarcl " NW or "EnergyGuard' Ultra" or "EnergyGuarcl " NH Ultra" or "EnergyGuarcl ' RA" or "EnergyGuard— RN" or "EnergyGuarcl " RW or "EnergyGuarcl ' RF" or "EnergyGuard' RM", any thickness or any UL classified wood fiber board, mechanically fastened. Cover Board (Optional): — 1/2-in. thick "EnergyGuard' HD" or 1/2-in. thick "EnergyGuard' HD Plus" or "EnergyGuardTM NH HD" or EnergyGuard— NH HD Plus", mechanically fastened. Membrane: — "EverGuard® TPO" 45-mil to 80-mil or "EverGuard Extreme® TPO" 50-mil to 80-mil, mechanically fastened. 10. Deck: C-15/32 Incline: 1/2 Slip Sheet: — Two plies "VersaShield® Fire -Resistant Roof Deck Protection" or one ply "VersaShield® Solo'' Fire Resistant Slipsheet", mechanically fastened. Insulation: — "EnergyGuardTM"' or "EnergyGuard' NH" or "EnergyGuardTM RF" or "EnergyGuard' Ultra" or "EnergyGuard' NH Ultra" or "EnergyGuard— RA" or "EnergyGuard- RN" or "EnergyGuard' RW or "EnergyGuard' RM", any thickness or any UL classified wood fiber board, mechanically fastened. Cover Board (Optional): — 1/2-in. thick "EnergyGuarcl " HD" or 1/2-in. thick "EnergyGuardTM HD Plus" or "EnergyGuardTM' NH HD" or "EnergyGuard— NH HD Plus", mechanically fastened. Membrane: — "EverGuard ® TPO" 45-mil to 80-mil or "EverGuard Extreme® TPO" 50-mil to 80-mil, mechanically fastened. 11. Deleted. 12. Deleted. 13. Deleted. 54 of 62 4/17/2019, 10:01 PM