Loading...
RF-19-1708Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 C� T-'q 'A- k� Issue Date: 07 Location Address Parcel Number 705 NE 92ND ST, Miami Shores, FL 33138 1132060141561 Contacts Permit No.: RF-07-10-1708' Permit Type: Roof Work Ctassificatfon: Repair Roof Permit Status: Approved' Expiration: 01/21/2020 LESTER DONALDSON Owner PAUL BANGE ROOFING, INC. Contractor 705 NE 92 ST, MIAMI SHORES, FL 33138 PAUL BANGE Mobile: 3053437784 7000 SW 21 Place, Davie, FL 33317 Business: 9549817663 shelly@paulbangeroofing.com Description: REPAIR ROOF TILE Valuation: $ 5,279.00 Inspection Requests: 305-762-4949 Total Scl Feet: 200.00 Fees Amount Application Fee - Other $50.00 CCF $3.60 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $1.20 Roofing Fee $50.00 Scanning Fee $12.00 Technology Fee $6.25 Total: $129.30 Payments Date Paid Amt Paid Total Fees $129.30 Credit Card 07/25/2019 $129.30 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In acceptifp this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are require for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. ERS AFFIDAC1rtify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws siting constructi and ning. Futhermore, I authorize the above named contractor to do the work stated. Signature: / Contractor / Agent Date July 25, 2019 Page 2 of 2 Miami Shores Village RECEIVED Building Department Ju 25L 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 BY; INSPECTION LINE PHONE NUMBER: (305) 762-4949 I (-w �FBC 20 )G BUILDING Master Permit No. Y�J -04— ` PERMIT APPLICATION Sub Permit No. — BUILDING ❑ ELECTRIC❑ ROOFING ❑ REVISION ❑ EXTENSION RENEWAL PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 705 NE 92nd Street City: Miami Shores County: Miami Dade Zip: Folio/Parcel#:11-3206-014-1561 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FIFE: OWNER: Name (Fee Simple Titleholder): Lestor Eugene Donaldson Phone#:305-343-7784 Address:705 NE 92nd Street #2 City: Miami Shores state: FL Zip: 33138 Tenant/Lessee Name: N/A Phone#: Email: N/A CONTRACTOR: Company Name: Paul Bange Roofing, Inc. Phone#: 954-981-7663 Address: 7000 SW 21 st Place City: Davie State: FL Zip: 33317 Qualifier Name: Paul Bange Phone#: 954-981-7663 State Certification or Registration #: CCC033691 DESIGNER: Architect/Engineer: N/A Certificate of Competency #: one#: Address: City: State: Zip: Value of Work for this Permit: $ 5,279.00 Square/Linear Footage of Work: 3,848 Type of Work: ❑ Addition ❑ Alteration ❑ New Q Repair/Replace ❑ Demolition Description of Work: f'.i s i�' 7� I Specify color of color thru tile:__T'��-_ � " Submittal Fee $0 Permit Fee $ CCF $ Scanning Fee $ Technology Fee $_ Structural Reviews $ Radon Fee $ Training/Education Fee $ DBPR $ CO/CC $ Notary Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) (vtoZ/vZ/ZOP@Slnaa) WIO matnad leinlDwIS 2uluoZ .Iau1wex3 sueld �? L Ag a3AMIddd mtiy R,retr,:J leuari, � ;�i. ,��y :leas K :leas Wild :UOIS 17 i(G{ D,) y` of n ,�a loN •q}eo ue a>Ie; plp oqm pue uol}ealpluapl :}Ulad rpuoi�Ioain}; ?'Ind/,�elo;� ' " ue a e i d m ue uol;eal !jUa I se paanpoad seq oqm ao @L11 L paanpoad seq oqm jo aua of umou>I AIleumad sI ogrn k K.19 of umou>I AIleumad sl oqm' g�qe /sq`/�OZ / }o /sep �• �q 'OZ 4 }o/ l slq}`a aao}aq pa palmou>lae sern. awna;sul 3�ii� U slg� au�aa }aq pa�palrnou>lae sem �u, najsursu.102R.Io} aql 2 OiD 'MOD 1N39d ao N3NM0 / a.I JeUBIS ainjeuSiS I r •pa6apga aq 111m aaf u0l43adsul0.1 0 pup pan J o aq you lym uopDadsui age `aor4ou pa4sod vans fo aauasgp aq; ul •panssi sl �lwaad FulpIlnq age ID3fD sApp (Z) uanas sanaao garym uo.tPadsul 3salf aq4 dof ails qof age;o pa4sod aq �snw }uawaauawwoa fo aar}ou papaoaaa agl fo Adoa palfivaa o 'os/y •3uawgap4. D o� �aafgns si IivadoJd asogm UOUad ago 01 paaanlIap aq qlm aangaoaq MD1 uaY uo.gDna4suo0 pup luawaouawwo0 fo aai4ou aq4 fo ifdo3 o 4og4 g4tof pooh ur aslwoid gm ;upoilddo age `005Z$ duipaaoxa anIpn p3pau Isa u0 q4!m 3lwaad Fulpllnq p fo aau0n5si ag.4 o4 uoRfPUOa p sy :4upoi1ddy o� a .qON «'1N3UV3:)N3UVUV0:) 30 DUON af1OA JNIGHOAM 3UO339 A3NHO1iV NV HO H3®N31mnOA H111"iinSN0: `E)NDNVN13 NId19O 01 ®N31N1 nOA Al 'AiU3dOHd unoA 01 S1N3VY3AOUdVYI HO3 DIMI JNIAbd unOA Ni 11f1SM AVVV 1N3UV3:)N3VVVU0:) 30 DIlON d ®bO339 01 3bnim unoA :113NMO 01 ONINbdM„ -2uluoz pue uollanalsuo:) Buljeln; as smel algealldde Ile glIm aauelldwoa uI auop aq lllrn >liom Ile jeq; pue @Ieanaae sl uoi;E!w Io}ul 2upSaao} aq; Ile ;eq; /s}Ijaaa I :-LIA /®I33tf S,u3NM0 "'013 `SiI3NOUIGNOJ iIiV `S>INbl `S'dRV3H `S2131108 `SDDVMlI13 'S100d `SN91S `9NIOAnld `JR110313 .Io} paanaas aq Isnw ;luaaad a}eaedos e jegj puelsaapun 1 'umpipsunf sly uI uoilanalsuoa guljelnSaa smel Ile }o spiepuels aqj ja@w of pawjopad aq IIIm >liom Ile ;eqj pue jjwaad e }o aauenssl aq; o; aolad paauawwoa seq uoljelle}suI ao >laom ou 1eq} /s}llaaa I •pa;ealpul se suollelle}sul pue >iaom aqj op of;luwaad e ule}go o} apew Agaaaq sl uol}eallddy dIZ dlZ aj ejs A;ID ssaippy s,.Iapual a2e2jaoN (algeallddep) aweN s,.Iapual @Oef1JOIAI alels Alb ssaappd s,Ruedwo0 2?ulpuog (algealldde }I) auaeN s,Aued'uao:) Oipuoq Property Search Application - Miami -Dade County Page 1 of 1 -.O.FFICE OF TOH"E PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-014-1561 Property Address: 705 NE 92 ST Miami Shores, FL 33138-2960 Owner LESTER EUGENE DONALDSON GRACE DONALDSON Mailing Address 705 NE 92 ST 2 MIAMI SHORES, FL 33138 USA PA Primary Zone 3000 MULTI -FAMILY - GENERAL Primary Land Use .-....___..... 0803 MULTIFAMILY 2-9 UNITS: MULTIFAMILY 3 OR MORE UNITS _ Beds / Baths / Half 8/8/0 Floors 2 Living Units 4 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 4,789 Sq.Ft Lot Size 8,580 Sq.Ft Year Built 1965 Assessment Information Year 2018 2017 2016 Land Value $171,600 $257,400 $257,400 Building Value $225,677 $202,600 $162,600 XF Value $0 $0 $0 Market Value $397,277 $460,000 $420,000 Assessed Value 1 $397,277 $382,386 $317,112 Benefits Information Benefit Type 2018 2017 2016 Non -Homestead Cap Assessment Reduction $77,614 $102,888 Homestead Exemption $25,000 $25,000 Second Homestead Exemption 1 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 565342 MIAMI SHORES SEC 3 PB 10-37 PARTS OF LOTS 22-23 BEG 25FTE OF SW COR LOT 22 E75FT NW135FT W57FT SE131.23FT TO POB BLK 63 Generated On : 6/18/2019 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $50,000 $0 Taxable Value $347,277 $332,386 $317,112 School Board Exemption Value $25,000 $25,000 $0 Taxable Value $372,277 $435,000 $420,000 City Exemption Value $50,000 $50,000 $0 Taxable Value $347,277 $332,386 $317,112 Regional Exemption Value $50,000 $50,000 $0 Taxable Value $347,277 $332,386 $317,112 Sales Information Previous OR Book - Price Qualification Description Sale Page 30355- Corrective, tax or QCD; min 12/08/2016 $100 3907 consideration 25316- Sales which are disqualified as a result 06/01/2006 $0 0590 of examination of the deed 19740- ....... 06/01/2001 $320,000 Sales which are qualified 2237 16459- 07/01/1994 $170,000 Sales which are qualified 1804 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at hftp://www.miamidade.gov/info/disclaimer.asp https://www8.miamidade.gov/Apps/PA/propertysearch/ 6/18/2019 I ROOF ASSEMBLIES AND ROOFTOP STRUCTURES CEIVED 2 5 2 19 Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form .... .... ...... . . Section A (General Information) ...... .. ' ...... ter Permit No. Process No. Paul Bange Roofing • � • • � • • • � • • • Contractor's Name 705 N.E. 92nd Street Miami Shores Flohda 331 38 •••;:• Job Address ROOF CATEGORY . . . . • • • • • • ...... Law Slope ❑ Mechanically Fastened Tile Mortar/AcVesive Set Tile' • • • • ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 160 Are there Gas Vent Stacks? ROOF TYPE Yes p No C( ❑ New roof Repair ❑ Maintenance ❑ ,Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF)552' Steep Sloped Roof AREA (SSF)31296 Total (SF) 3, 848' Totoi fir'-" Section B (Roof Plan) c Ske c Ilustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow dralns. Include dimen- si tlo d levels, clearly Identify dimensions of elevated pressure zones and location of parapets. 41'1" i� 2215" Flat 2s'�° .� • N �I �.. 41,1;, 06 4' 10" �' 4' 51' 11 " N �4 �� Two Story Slope 9�4 N C0 4,9„ ry 4'3" ao L _A "iiamr Shores Village PROVED I BY I DATE DEFT I O )',I 'I ANC WITH ALL FEDERAL 95'2" p to 100 square feet each 1 `/ R! 1LrS AND RFG1)I ATIONS ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition 2017 High -Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) 000000 Roof System Manufacturer: Monier Tile Notice of Acceptance Number: • Minimum Design Wind Pressures, If Applicable (From RAS 127 or • Calculations): • • : 1: P2 • P3: ' ICP Adhesive AH-160 Foam/Cement Modiefied Repair- Steep Sloped Roof System Description -Peel Stick Base Peel Stick Modified Bull Granules \ Deck Type: 15/8 Plywood Type Un Roof Slope: derlayment: JASTM #30 Felt Type 2 D226 —' 12 Insulation: N/A Fire Barrier: N/A e• Ridge Ventilation? Fastener Type & Spacing: 1-1/4" RS Nails 6"OC Lap, 2R0w @ N/A Adhesive Type: N/A Type Cap Sheet: N/A Mean Roof Height: 16 Roof Covering: ame as existing -Monier Type & Size Drip N/A Edge: 15.34 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING Z"OC Field MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Sbmol Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) • Miami, Florin& i31�5-2474..... BOARD AND CODE ADMINISTRATION DIVISION T N§)31=-2590 F.Q96) 3J5-2599 .' NOTICE OF ACCEPTANCE (NOA) ay4wntiamidaduzovLeconomw • • • : • ICP Adhesives and Sealants, Inc. 12505 NW 44te Street • Coral Springs, FL. 33065 ...... . ... ..... .. .. .. . ...... SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of Mnstruetion luvals. The" "" documentation submitted has been reviewed and accepted by Miami -Dade County RER-Prcgluct Control Section to be: • •..: used in Miami Dade County and other areas where allowed by the Authority Having Jurisdictidii (AHJ). : .". ' ... • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset' AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 t+NAMwsaDEC Expiration Date: 05/10/22 :• Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing • • • • Sub Category: Roof tile adhesive • • 0000 Materials: Polyurethane • " • "' • SCOPE: •••••• • This approves ICP Adhesives Polyset' AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as dereWn1d by applipatle building code, do not exceed the design pressure values obtained by calculations in complianWvAth Roofing' Application Standard RAS 127. For use with approved flat, low, and high profile roof tile sygttii$s ling ICP Adhesives Polyset® AH-160. • PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications ICP Adhesives N/A TAS 101 PolyseeAH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Product Descrintion Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: ProveProverty Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs./fl.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ftz 3.1 Perm / Inch +0.07% Volume Change @ -400 F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2of11 EVIDENCE SUBMITTED: Test Ai!encv Test Identifier Test Name/Report •••• UL• Center for Applied Engineering #94-060 TAS 101 • • • 04fOW24; • , 257818-IPA TAS 101 •••;•• 12/16/960 •'•'•• 25-7438-3 SSTD 11-93 """ 10/25/95 V * s o: 25-7438-4 • " " • 0 25-7438-7 SSTD 11-93 • � � • 11702M • �: � • • 25-7492 SSTD 11-93 1242 Miles Laboratories NB-589-631 ASTM D 1623 02401/94 Polymers Division """ •...;. Ramtech Laboratories, Inc. 9637-92 ASTM E 108 .. . • • • 0473491 • . • Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a cugent IyOA thdt.lws' .....0 attachment resistance values with the use of ICP Adhesives Polyset® AH-160. ' ..' : ... . • 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Al VIVation section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP:....: Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or eKc*e bhe resWance•value • • determined in compliance with Miami -Dade County Roofing Application Standards RA�127. The a�hiye • • • ...... ..... attachment data is noted in the roof tile assembly NOA. • • .. .. .. . ...... 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance N4dr?p0fing Appiication • Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintellance $QQlat. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed byJ(5-.Adhesives and ; • • •' Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the autl>hAyh%ving jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPace 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4of11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum taddyGranj Area . Wfkbt •• Eave Course -Flat, Low, High All Eave Course 17-23 sq. inches ..;.. 45-65. Profiles • Flat, Low, High Profiles #1 17-23 sq. inches 45-65..' Flat Profile #2 10-12sq. inches •;••; 30 Low Profile #2 12-14 sq. inches 30 . High Profile #2 17-19 sq. inches Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 4012:gram%per.]Raddy ; head of tile 9-11 sq. inches at '.:..' overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5of11 ADHESIVE PLACEMENT DETAIL # 1 elm raw. Flat/Low Profile Tile sell, 1. Starting at the eave course,.4pl� a minimum-2" • s (50.8 mm) x 10" (254 mm) x %14'•(25.4 mm) foam • • • • % • paddy onto the underlaymmnA mitioned aseshown • under the strengthening rjPC1b8gst to t4(! pv0rjock • of the tile being set. • • •' •' 2. Continue in same manne Insure approximately 17 • ? (109.7 cm2) — 23 (148.4 cnj square inch adhesive • contact with the understdjo of the tile. • • • • % • • • • • % • Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.. 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6of11 n ADHESIVE PLACEMENT DETAIL # 2 Flat/Low Profile Tile . . .... ...... 1. Starting at the eave course, a ly a minimum2"{50.8 �. mm) x 10" (254 mm) x 1" (f�3 �M) foam p a& onto the underlayment positio49 , 0 as show�un jer the • • • • strengthening rib of the tile O(qt j to the Qverjgek of ....0 the tile being set. Insure appVWVWely 17 Q0.9.1 cmZ)..;..' — 23 (148.4 cmZ) square inch adWtve coftcfw:th the...... underside of the rile. ...... . . • . . . ...... 2. At the second course, apply a m ant: um 2i (Sa.8mm) 0 *" x 7" (177.8 mm) x 1" (25.4 mm) folm paQdx btito the ' ' underlayment positioned as shown under tW •' strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm) - 12 (77.4 cm') square inch adhesive contact with the underside of the rile. Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm') — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cmZ) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7of11 W�n ADHESIVE PLACEMENT DETAIL # Z (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paXy onto the underlayment positioned as rhomUnder the pan • • • portion of the tile closest to the overlock off` [la �t�le ; being set. • • • • • • • 3. Continue in same manner. I ?sjqg approxiMdtP.Vl7" ..... (109.7 cmZ) -19 (122.6 cm2jsgwe inch adhesive • •: • • contact with the underside of tlf .ore. • .• • • • • • • re. : • . . . . ...... NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT RETAIL # 3 m " `c 3xab. " Nlwc��W. P PrOMT8a Nkftm Pr+fa7fM APPROVED 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in' (109.7-148.4 cm2) of adhesive contact with the underside of the tile . . .... ...... 2. Apply a 4" (101.6 mm) x4""(101.6 mrAJ $d':(25.4 • • mm) foam paddy onto the M4&layment just below the second course line pogiiione$ foam&a dy • • • • • • • • under the strengthening riefor l6t the *oryrlder the • • . • pan portion of the tile, closest to the undprlppt for .. ; ..' the second course tile to b �in�t led. Ih64i% ; ...... approximately 8-9 in2 (51.6.�$ J cm2) of adhesive • • contact with the undersid(:of thc:tile. • • • • • • (Instructions continued on next page) • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9of11 ADHESIVE PLACEMENT DETAH! # 3 (CONTINUED) "10 TIM 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x %" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cmZ) - 11 (71cmZ) square inch adhesive contact with the underside of the rile at the overlap and 7 (45.2 cmz) - 9 (58.1 cmz) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same mavnor. ...... . ... NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 1 +) ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 211Wrn 2,owerti �Aotrn. PNiae �iastw k� to t M.►roim out�ids edgsadf aw.r dh. ,�+ tha+ tnsgdl ei�e. �nsutrr � w}.� �i ) Rinwrwtopportw" !>Men»awrsaaweseNa hbufmseaond"wool p•n 0hm& mrive of p" 0W C0V" rsm ot*m ins.. Two Plem Sarre i -High P'rafiletlk APPROVED Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 nun) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure • • • • approximately 65 (419 A cm;) — 70 (45 i 6 m2) • • • • ;' square inch adhesive contact with the We jside ' . of the tile. •••••• pan 3. Turn covers upside dov�0 �ApQsing tie underside of the tile. Apply a minimum 1" (25.4 x 10" • • • • • 254 nun bead of adhesive`cGr ctly o%ft Omer • edge of each side of the coven file. Leave. .' approximately 3/4" (19 =nm) tg 1" (2�A min) ....: • from the outside edge o f the tjle, inwVcr free of • foam to allow for expantioV. • .00. 4. Turn cover tile over after foam is applied and place onto pan rile course. Insure a minimum of 20 (129 cmz) - 25 (161.3 cmZ) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 • 1�91®QADE ; • "Delivering Ezceilence Every Day" ------ MIAMI-DADE COUNTY ------ REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this form. The owner's initials in the designated space indicates that the item has been explained. 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as Rart of the agreement between the owner and the contractor. •. • • . .... ...... 2. Renailing wood decks: When replacing roofing, the existing wood roof 14 niay hzt*e*jo be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurritarie Zones) of the Flgrida . ...... ...... Building Code. (The roof deck is usually concealed prior to removing the existing roof"3istem). •• • Goo* 3. Common roofs: Common roofs are those which have no visible delineationJ)&4veen peig*1boring••0 units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofilfg tbntractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. ....:. ...... 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the Woof decking cane • viewed from below. The owner may wish to maintain the architectural appearance; therefore, roolffig nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of m ' taining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 077 6.Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance w the requirements of Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Owner's/Age Contractor's S Property Add ---- - - / nt s Signature: Date: / ignature , _ Permit Number: ress:i (� -