Loading...
PL-19-1723Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 08/16/2019 Location Address Parcel Number 1201 NE 94TH ST, Miami Shores, FL 33138 1132050100010 Contacts Permit No.: PL-07-18-1723 Permit Type: PW b ing - Residential Work Classification: Gas Permit Status: AppVOVe d Expiration: 02/12/2020 BERNARD & DEMETRIO LORIS LEE Owner 1201 NE 94 ST, MIAMI SHORES, FL 33138 Other: 9546736513 PRESTIGE GAS SERVICES CORP. Contractor LAZARD PAZ-ASLAN 1511 SW 71 CT, MIAMI, FL 33144 Business: 3053000608 Ins section Requests: Description: ELECTRICAL ALTERATION NEW ATS & FEED TO Valuation: $ 2,400.00 NEW GENERATOR 30-762-4949 Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $1.80 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.60 Permit Fee $50.00 Scanning Fee $9.00 Technology Fee $2.50 Total: $117.90 Payments Date Paid Amt Paid Total Fees $117.90 Credit Card 08/16/2019 $117.90 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all he foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Fine, more, I authorize the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Date August 16, 2019 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 JUL 2 5 201 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20C? }� BUILDING Master Permit No.t 01"t t—Q22— PERMIT APPLICATION Sub Permit NoT �v I ��cl'11 2-S ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP 6-4- 3 CONTRACTOR DRAWINGS JOB ADDRESS: I -d I NG —` / : City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: // �32�y t9ly —do/0 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple�Tiitlehoolld`er): lJb,/�l ��Y/ 6 L (l i�/S Phone#: %S 6 5'i ? g ��� Address: i zo l 96 ! "f -�-h s - ' City: ft 1"alm I' .SI/lOa State: / Zip: 3:3/3,8 Tenant/Lessee Name: Phone#: SA M Email: _ r CONTRACTOR: Company Name:Phone#: �oS�� ©3 Address: «z/ mot/ 7-1 G;7— City: % State: Ar Zip: `3 3 iLIG� Qualifier Name: State Certification or Registration #: DESIGNER: Architect/Engineer: Value of Work for this Permit: $, Type of Work: ❑ Addition Certificate of Competency #: City: State: Zip: 3 Square/Linear Footage of Work: ❑ Alteration nNew ❑ Repair/Replace ❑ Demolition Description of Work: ^Aee(/ <2-1--3 Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ DBPR $ Notary Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding•Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In,tfia absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. i Signature Signature O R or AG NT CO The foregoing instrument was acknowledged before me this day of� ��:��fZ 20 C by Lo� S r ;LT(� J(24J, who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign The foregoing instrument was acknowledged before me this day of 1.20'� by LYG-1 2 -4y Ld Z4W 61 Vv o is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: M i,IC�Vl11, �Y Print Print e r j Seal• aP Notary Public State of Florida Seal: �' Michelle Perez My Commission GG 084089 '^uynl�3N�?•.c5�Expires04/08/2021 APPROVED BY �"---� /��l Plans Examiner as Zoning Structural Review (Revised02/24/2014) Clerk GENERAL` CIL 16/20/221kWj`Ai:t­­,-.-," `-,?"',Ly I'fGUARDIAN® SERIES -�---DAI Residential Standby Generators Air -Cooled Gas Engine INCLUDES: • True Power'"" Electrical Technology • Two Line LCD Multilingual Digital Evolution'" Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp Pre -Wired Switch or 200 Amp Service Rated Switch. See Page 4 for Details. • Electronic Governor Standby.PbVar Ratin�q . ..... Models 006459-0, 006461-0, 006462-1 (;reef. ..-:iisquer,.16.. IrW 60 Hz • Model 006721-0 (Alurrlfngm•- Gray) - 19 kW 60 4 � • : • Models 006729-1, 006730-0 (NeeT * Nsque� 10 kW 60 4-,- Models 006551-1, 006552-0 (Alu%raLi; - Gra4 %' I!VV 601 ".. . ...... . ... .. . .. .. .. . ...... • External Main Circuit Breaker, System Status & Maintenance Interval LED Indicators • GFCI Duplex Outlet • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Composite Mountin Pad • � .. .... % � s GENERAC - --� ..- g U QUIET F_T • Natural Gas or LP Gas Operation `(&, • 5 Year Limited Warranty LISTED Note: CUL certification only applies to unbundled units and units packaged with pre -wired switches. • Capability to be installed within 18" (457 mm) Units packaged with the Smart Switch are UL certified in the USA only. of a building* *Only it located away from doors, windows and fresh air intakes, and unless other- wise directed by local codes. FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit, from the utility quality power. This allows confident operation of sensitive electronic engine to the smallest electronic component. equipment and micro -chip based appliances, such as variable speed HVAC systems. GFNFRAr TRANSFER SWITfHFS. Long Life and rehabi.li.ty are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. w GENERACnUS A ry0,1 - — ,� �R trj� = i O • • Mobile, PROMISE *� �* `ink , MEP '9RgPN • Built in the USA using domestic and foreign parts. GENERAC' 16/20/22 kW features and benefits Engine • Generac (OHVI) design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • Quiet Test'" Greatly reduces sound output and fuel consumption during bi-weekly exercise, compared to other brands. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. *Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. -Full ,pressure lubrication system -Low oil pressure shutdown system -High temperature shutdown Generator -Revolving field -Skewed stator -Displaced phase excitation *Automatic voltage regulation •UL 2200 listed Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • •.. Shutdown protection prevents catastrophic engine damage due to low oil. •" Prevents damage due to overheating. • •www•• •• •wwww• • •wwww• Allows for a smaller, light weight unit that operates 25% more efficiently than2gvp�mg arma:re•g vator Produces a smooth output waveform for compatibility with electronic equipme*v • • • Maximizes motor starting capability. • • • • • • • Regulates the output voltage to ±1 % prevents damaging voltage spikes. For your safety. Transfer Switch • Fully automatic Transfers your vital electrical loads to the energized source of power. -Pre-wired, color -coded conduits (Pre -wired switches only) -Remote mounting Ensures the easiest, trouble -free installation. Mounts near your existing distribution panel for simple, low-cost installation. Evolution" Controls •Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. -Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. •Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. *Utility voltage sensing Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. -Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. •Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. •Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. -Electronic governor Maintains constant 60 Hz frequency. .. ............. Unit -SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. -Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. -Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building.` Installation System • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. -Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities 16/20/22 kW GENERAC® specifications Generator Model 006459-0, 006461-0, 006729-1, 006730-0, 006551-1, 006552-0 006462-1, 006721-0 (16 kW) (20 kW) Rated Maximum Continuous Power Capacity (LP) 16,000 Watts* 20,000 Watts* Rated Maximum Continuous Power Capacity (NG) 16,000 Watts* 18,000 Watts* 19,500 Watts* Rated Voltage 240 240 240 Rated Maximum Continuous Load Current — 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5% Main Line Circuit Breaker 65 Amp 90 Amp 100 Amp Phase 1 1 1 Number of Rotor Poles 2 2 • • 2 • Rated AC frequency 60 Hz 60 Hz • • •.fiii• ...... Power Factor 1.0 1.0 • • •' : • ..1.0 . .' Battery Requirement (not included) Group 26R, 12 Volts and 525 Cfq.VWrQL1n ' •; • • • • Unit Weight (lb/kg) 513/232.7 (Steel), • 516/234.1 • • • • • • 526/l38.6 448/203.2 (Aluminum) • • Dimensions (L x W x H) in/mm 48 x 25 x 29/1218 x 6380T2 • • : • • • . ' ' Sound output in dB(A) at 23 it (7 m) with generator operating at normal load** 66 66 "" ' to ""' • Sound output in dB(A) at 23 ft (7 m) with generator in Quiet Test'" low -speed 60 60 • • • 0 • • • • • • • • • • • exercise mode* * . • .. 58• • • . • .... . Exercise duration 5 min 5 min ...... 5 &rin ' • Engine ...... Type of Engine GENERAC OHVI V TWIN GENERAC OHVI V TW4N • • • GENERAC OHVI V-TWIN • • • • Number of Cylinders 2 2 " ' : .10. Displacement 992 cc 999 cc ' It) 9 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magneto Governor System fiecironic flec�c Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including Filter Approx. 1.9 gV1.8 L Approx. 1.9 gV1.8 L Approx. 1.9 gV1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas ft3/hr (m3/hr) 1/2 Load 193 (5.47) 205 (5.8) 184 (5.21) Full Load 312 (8.83) 308 (8,72) Liquid Propane 0/hr (gal/hr) [Vhr] 281 (7.96) 1/2 load 72.4 (1 99) (7.531 75.6 (2.08) [7.87] 83 (2.16) [BA61 Full Load 130 (3.19) [13.531 140 (3,85) [14.57] 127 (3.68) [13.99] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-13 mm mercury) for natural gas,10-12" water column (19-22 mm mercury) for LP gas. For Btu content, multiply ft3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Controls 2-Line Plain Text Multilingual LCD Display Mode Buttons: Auto Manual Off Ready to Run/Maintenance Messages Engine Run Hours Indication Programmable start delay between 2-1500 seconds Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) Future Set Capable Exerciser/Exercise Set Error Warning Run/Alarm/Maintenance Logs Engine Start Sequence Starter Lock -out Smart Battery Charger Charger Faull/Missing AC Warning Low Battery/Battery Problem Protection and Battery Condition Indication Automatic Voltage Regulation with Over and Under Voltage Protection Under-Frequency/Overload/Stepper Overcurrent Protection Safety Fused/Fuse Problem Protection Automatic Low Oil Pressure/High Oil Temperature Shutdown Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown High Engine Temperature Shutdown Internal Fault/Incorrect Wiring Protection Common External Fault Capability Field Upgradable Firmware Simple user interface for ease of operation. Automatic Start on Utility failure. 7 day exerciser. Start with starter control, unit stays on. If utility fails, transfer to load takes place. Stops unit. Power is removed. Control and charger still operate. Standard Standard Standard (programmable by dealer only) From 140-171 V/190-216 V Standard 50 Events Each Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter cannot re-engage until 5 sec after engine has stopped. Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard "Sound levels me taken from the front of the generator. Sound ievetstaken tram other sides of the genaM may be higher depending an rnstalhafion parameters. Rating definitions - 84andby. Applicable for supplying enrerger cy pave is the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level, and also wilt decrease about 1 percent for each 6 °C (10 °n above 16 °C (60 In. GENERAC� 16/20/22 kW Pre -wired Features Model available on Steel 16 kW models only No. of Poles • Electrically operated, mechanically -held contacts for fast, positive Current Rating (Amps) Connections. Voltage Rating (VAC) Utility Voltage Monitor (Fixed)* • Rated for all classes of load, 100% equipment rated, both inductive and -Pick-up resistive. -Dropout • 2 pale, 250 VAC contactors. Return to Utility* Exercise weekly for 12 minutes* • 30 millisecond transfer time. UL Listed Total of Pre -wired Circuits • Dual coil design. No. 15 A 120 V • Main contacts are silver plated or silver alloy to resist welding and sticking. No. 20 A 120 V No. 20 A 240 V • NEMA 1 (indoor rated) enclosure is standard on the pre -wired switch. No. 30 A 240 V No. 40 A 240 V • Pre -wired 30 foot (9.1 meter) whip to connect to the provided 5 foot pre- No. 50 A 240 V wired whip and external connection box. Circuit Breaker Protected Available RMS Symmetrical • Pre -wired 2 foot (0.61 meter) whip, color coded to connect into the Fault Current @ 250 Volts existing electrical panel. *Function of Evolution Controller Dimensions Mechanical Olmensions Height Width Depth H1 H2 W1 W2 in 23.5 26.4 8.3 1 12.6 6.3 mm I 320.7 159.6 Wire Ranges Conductor Lug Neutral Lug Ground Lug 2/0-#14 210-#14 210-#14 Service Rated Switch Features • Electrically operated, mechanically -herd contacts for fast, clean connections. • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • NEMANL 3R aluminum outdoor enclosure, • Main contacts are silver plated or silver alloy to resist welding and sticking. Dimensions 200 Amps 120/240, 1e Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 27.24 30.0 11.4 13.5 7.09 mm 692.0 762.4 289.0 343.0 180.0 switch options 006461-0 (16 kW) 2 100 120/240, 10 80% 60% approx. 15 sec. Standard Starlhfrd •, ?6••• •• • •i• • . • • 1 ...... . ... 10,000• • H2 '.I. ., H1 W1 — w2 - Model 006462-1 (16 kW)/006729-1 (20 kW)/006551-1 (22 kW) No. of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 120/240, 10 Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 60% Return to Utility* approx. 13 sec. Exercise weekly for 12 minutes* Standard UL Listed Standard Enclosure Type NEMA/UL 311 Withstand Rating (Amps) 22,000 Lug Range 250 MGM - #6 *Function of Evolution Controller GENERAC� 16/20 2�L available accessories Model # Product Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have 006463-3 Mobile Link" access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact@). If the temperature regularly falls below 32 °F (0 °C), a cold weather kit is required to maintain optimal 006212-0 Cold Weather Kit battery and oil temperatures. Kit consists of a battery warmer and oil filter heater with built-in thermostats. . • Auxiliary Transfer Switch Contact The auxiliary transfer switch contact kit allows the transfer switcltito %cl out a si%;J0a`rgeelectrical 005621-0 Kit .' load you may not need. Not compatible with 50 amp pre -wired switrbas • • • 005839-0 - Bisque Fascia Base Wrap Kit* 005666-0 - Gray (Standard on 22 kW) M".1"0- 005703-0 - Bisque Paint Kit* 005704-0 - Gray 006484-0 -16 kW 006485-0 - 20 & 22 kW 006664-0 006873=0 Scheduled Maintenance Kit Wireless Remote Monitor Smart Management Module (50 Amps) • The fascia base wrap snaps together around the bottom of the ITelv`a titled generators. This offers • a sleek, contoured appearance as well as offering protection frolnrodmts and insects by covering the lifting holes located in the base. 000000 : * 0 0 0 00000 If the generator enclosure is scratched or damaged, it is important:A64h-up tht pin: m;rotect • • • • • from future corrosion. The paint kit includes the necessary paint to properly maintainertouch-up a • • • • . . generator enclosure. . 0 *: • . • .' Generac's scheduled maintenance kits provide all the hardware necessary to perfar"wmilete '*00:0 routine maintenance on a Generac automatic standby generato( • • • Completely wireless and battery powered, Generac's wireless remote monitor pro'lligIALPwith instant status information without ever leaving the house. Not compatible with CorePower or EcoGen systems. Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power.management,capabiliiies. It provides .additional power man,nagement flexibility not found in any other power management system. * Note: Bisque kits are used in conjunction with steel enclosures. Gray kits are used in conjunction with aluminum enclosures. 731.9 mm [28.8 in] dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 4 -- 14, -- -- i_ - [25.3 in] ram.° „ J LEFT SIDE VIEW FRONT VIEW Model UPC 006459-0 696471064599 0064610 696471064612 006721-0 696471067217 006729-1 696471067293 006730-0 696471067309 006551-1 696471065510 006552-0 696471065527 006462-1 696471064629 GENE RAC' Generac Power systems, Inc. • S45 W29290 HWY.. 59, Waukesha, WI 53189 • generac.com 4 02015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin OK8458-F Printed in U.S.A. 04/10/15 Automatic Transfer Switches GENERAL Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, $ingl-�;phasq,,,, ...... .. ...... . .... .. . . . . .... . .. ..... .... .. . ...... c nQLus '%­01 LISTED "CUL only applies to non -service rated switches Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an EVojUtjorjTM or Nexus TM Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service ,rated (BXSW) Generac Automatic Transfer Switches are housed .in.an aluminum NEMA/UL Type SR enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. * Non -service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. ISO "''MBO 90 20 GENERAC' 100-400 Amps, Single Phase Automatic Smart Transfer Switches Functions All timing and sensing functions originate in the generator controller Utilityvoltage drop-out......................................................................................................................................................................................................................<65% Timer to generator start..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer' Enginewarm up delay.................................................................................................................................................................................................................5 seconds Standbyvoltage sensor.................................................................................................................................................................................................65% for 5 seconds Utilityvoltage pickup.........................................................................................................................................................................................................................>80% Re -transfer lime delay...............................................................................................................................................................................................................15 seconds Enginecool -down timer.......................................................................................................................................................................................................•.•60•seconds Exerciser..............................................................................................................................................................5 or 12 minutes adjustable weekly/N-AV�44ftly.. ...... The transfer switch can be operated manually without power applied. • • • • • • • • 'When used in conjunction with units utilizing Evolution'" controls "Adjustable via the controller "';" ' • • • • • • • Specifications • • • Model RXSC10OA3 RXSW10OA3 RXSW150A3 RXSC20OA3 RXSW20OA3 RXSW300V• •:XSC400As • • R CW40W • Amps 100 100 150 200 200 300 • • • • • 400 • 400 Voltage 120/240, 1e 120/240, 10 120/240, 1e 120/240, 10 120/240, 10 120/240, 10 110/240, 1:. •:2,0/240, 1a�' Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transitfoa Service Rated '0p:n Transition • .Open TransitiQrl' Seaice Rated Enclosure Type NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 313 NEMA/UL 3R UL Rating UL/CUL UL UL UUCUL UL UL UL/CUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 1 22,000 22,000 22,000 Lug Range 1/0 - #14 250 MCM - #6 600 MCM - #4 or 1/0 - 250 MCM Dimensions Model RXSC10oA3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW20oA3 RXSW300A3 RXSC400A3 RXSW400A3 Height H1 17.24/437.9 17.24/437.9 26.75/679A 17.24/437.9 26.75/679.4 42.91/1089.9 31.25/793.8 42.91/1089.9 (in./mm) H2 20/508 20/508 30l762 20/508 30/762 48/12192 36/914.4 48/1219-2 Width W 1 12.5/317.5 12.5/317.5 10.5/266.7 12.5/317.5 10.5/266.7 16.69/423.9 19.18/487.2 16.69/423.9 (in./mm) W2 14.6/3703 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 Depth (in./mm) 7.09/180.1 7.09/180.1 6.3/160.1 7.09/180.1 6.3/160.1 10,06/255.5 10.06/255.5 10.06/255.5 Weight (lbs./kilos) 20/9.07 22.5/10.21 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 4_ { H2 , t- L J�,—— L-DEPTH-_ --_ .. w2 GENE RAC 4 Generac Power Systems, Inc. • S45 W29290 HWY.. 59, Waukesha, WI 53189 • generac.com ©2017 Generac Power Systems, Inc. All fights reserved. All specifications are subject to change without notice. Bulletin 10000013459-A 04/24/17 Demetrio Loris 1201 NE 94th Street Miami Shores, FL 33138 Existing METER Main 200 AMP NEMA 3R Longman Electric EC 13003713 95 NE 166th Street Miami, FL 33162 305-758-1211 NEW Nema 3R ATS 1 Phase 120 / 240 2/0 THHN PVC ,(-- #4 Ground xisitng 00 amp anel ROD 10' X 5/: ROD 10' X 5/ Cold Water ELECTRICAL REVIE'., l APPROVED T E_ §fA6gh '6i = t `'. DA e M1 CoUN7Y(-);u�_ TAe foregoing itstrament was acknowl•dg G� befom we dis V of , f . llj by (lame of person ackvowled&&n _— �.� NotaryPublic --- chelle Perez ` CorrO��csd w n Demetrio Loris 1201 NE 94th Street Miami Shores, FL 33138 Existing METER Main 200 AMP k3R Longman Electric EC 13003713 95 NE 166th Street Miami, FL 33162 305-758-1211 3# 2/0 THHN 2" PVC NEW 22 KW Nema 3R GEN 120/240 ATS 100 amp Main 1 Phase 120/240 •••• . •••• •••••• ...... ... • . . ....• .. so • • • • • • • • • • • 000000 • • • • • • 3-#3 THWN ••• • .....• 1-#8 Ground • • 0000 1-114" PVC ELECTRICAL REVIE'� V�c��Yl APt,RQ,,I STATE OF FL A COUNTY OF � I/T j�N iay of The foregoing iast cnt was acknowtedgedbefore this 1./ 1� by (name of on acknowl*i ng). pp o� f�'4 Notary Pubtic f Michelle Pere _ c� Commission GG 084089 o- i p � reWPAN& Identificati Type of Identification Produced IE 1201 NE 94th Street Miami Shores LOAD CALCULATION On Generator 2720 sqft x 3VA= 8160 . . .... •,.• ; ...... Small Appliance Dishwasher 3000 1000 ••• ELE-„""�""" A- ••.... •.: -,�;-�� j •• ....:. ;••••; AP0,vT--�` Microwave 1200 • ...• ; •..�' ..... Garbage Disposal 800 --� • • . o Frig 800 •••••• • wash machine 1000 . . . . •••••• ...... 15960 •• •• • -10000 •••• Longman Electric EC 13003713 95 NE 166th Street Miami, FL 33162 5960 x 40% 2384.00 21984 / 240 10000 2384.00 12384 9600 air conditioning 21984 full VA = 91.6 amperage STATE OF FLORWA COUNPYOF_di/j'iR9/ Da4f The foregoing 4astramcnt was acknowledged before me this # day of 20 19 by (mac of p-wn ack-wledgitW. e N v( iw / �� At I'd FIle Ic rtz- Type ,� Notary 1l ichelle Perez 32 in. Width AME,RICAST www.ameri-casting.com "MADE IN AMERICA!" FED TAX it 20-8252362 LICENSE 4599-20050163 5303 Palmetto Ave. Fort Pierce, Fl. 34982 Tel. 772-971-1958 Fax: 772-464-0509 Email: sales(riameri-castine.com or charlesnitt200]Gi vahoo.com 54 in. 6,000 psi Lightweight Concrete Mix Concrete Pad Plan n. t. s. Pad 1 - 32 in. Wide X 54 in. Long �3. in. 6,000psi. & MasterFiber Mac 100 Grid 4.0 in. - - - - - - - - - = - - - - - - - 1.0 in. r Structural Forming Foam I 1 53 in. ' ' 2.0 in. 2.0 in. Concrete Pad Section n. t. s. Calculations: Generator Model: Generac 22 KW 6551-0 / 6552-0 Length Width Height Weight Generator = 48.0 in. 25.0 in. 29.0 in. 526 lbs. Pad = 54 in. 32 in. 4 in. 370 lbs. qz = Velocity Pressure = 0.00256 x Kz x Kd x K2T x V2 Contributed Total Weight 896 lbs. V = Wind Speed = 186 mph. VZ = 34,596 Kz = Velocity Pressure Exposure Coef. At Height z = 1.03 Exposure D Eq. 16-12 (FBC 2010) Kd = Wind Directional Factor = 0.85 G = 0.85 K2T = No Escarpment = 1 Cf = [(1.3-1) x (H/L)] + 1 1.18 qz = 0.00256 x 1.03 x 0.85 x 1 x 34596 = 77.5 psf. Af = 9.67 sq.ft. Design Wind Force (F) = qz x G x Cf x Af 753 lbs. D = 896 lbs. Load Combination - Allowable Stress Design (D) = 0.613 + 0.6W Aspect ratio of generator Fig 29.5.1 OTM = (0.6) x Wind (F) x 1/2 Width = 7.2 kip. H/L = 29/48 = 0.6 RM = (0.6) x Deadload (D) x 1/2 Width 8.6 kip. FS = Safety Factor = OTM = 1.19 > 1 Anchor Bolts are OK by inspection Generac 005871 & 005883 1 OKW 387lbs (48in. X 25in. X 29in.) Generac 005872 & 005884 14KW 439lbs (48in. X 25in. X 29in.) Generac 6459 & 6461 & 6462 16KW 513lbs (48in. X 25in. X 29in.) Generac 006721 16KW 448lbs (48in. X 25in. X 29in.) Generac 005873 & 005885 17KW 4551bs (48in. X 25in. X 29in.) Generac 005874 & 005886 17KW 4211bs (48in. X 25in. X 29in.) Generac 005875 & 005887 20KW 451lbs (48in. X 25in. X 29in.) Generac 006729 & 006730 20KW 516lbs (48in. X 25in. X 29in.) Generac 006551 & 006552 22KW 526lbs (48in. X 25in. X 29in.) Kohler 14RES & 20RES 14-20KW 500lbs. (48in. X 26in. X 29in.) GE 40323GE & 40324GE 13KW 540.1bs (35in X 39.4in. X 39in.) GE 40330GE & 40331GE 20KW 600.lbs (48in X 33in. X 30.5in.) Briggs & Stratton 040243-0 1 OKW (320104) Briggs & Stratton 040302-2 12KW (5003.7501.6) Briggs & Stratton 040303-1 15KW (4903.7501.6) Briggs & Stratton 040304-1 18KW (4903.7501.6) Briggs & Stratton 040305-1 20KW (4903.7501.6) Horizontal Force = FH Generator Height = HI Uplift Force = U Generator Generator Length = LI «'ei¢ht = G or',Vidth = W Total Weight = D Due to expansion and shrinkage of prints, written dimension takes precedence over scaling It is the responsibility of the contractor to field verify all dimensions and adjust onsite as required. This Certifies that these plans meet or exceed the 186 mph ultimate wind speed of the 2010 Florida Building Code and ASCE 7-10 �� "41se" dr6640rvdhr sfleld. tr mr .Allanrrisle cSfpr1P*gJ.. 7u. 32714 Dross: ph. 407-bat-40 52 rt. 447-bat :laa 1 rhwengr @ earthlink.net DL0�9a G W W 1 Data: 06-29-2010 1 A-#& RHW I Sash: n.t.s. Specific Purpose Title of Page: Generator Pad Pre-Manuf. Concrete Specs Length = L2 ... •• • • •• .. Wind Speed = 186 MPH Wind Exposure Category = "D" Not Hazardous to Human Health P.E. Use. No. 97 Sheet 1 UG PrR 2013 7 54 3.0 t 48 AMERICAST www.ameri-casting.com "MADE IN AMERICA!" FFI) WAX 9 20-8252362 LICFNSE 4599-20050163 5303 Palmetto Ave. Fort Pierce, FI. 34982 Tel. 772-971-1958 Fax: 772-464-0509 Email: salesra ameri-castine.com or charlcsnitt2001ra vahoo.com Generator Size 25 in. Wide X 48 in. Long X 29 in. Tall Generator Placement Plan n. t. s. Simpson A24 Angle Brace w/ 4 - #10 Stainless Screws Generator -- 1/2" x 2" x 3" Galy. Metal Washer Generator Attachment Plate/� ,�' See Generator Specs-1/2" x 3" Titan Conc. Anchor Screw 2 ; _ 6,000 psi Lightweight Conc. Mix OPTIONAL: Rubber Vibration Pad j \\\ °a - ._.___Hole to be Epoxy Filled / 1 MasterFiber Mac 100 Grid Before Installing Screw , —� , Structural Foam Core 2"--- Optional Anchor Plan n. t. s. 54 3.0 3.0 3.0 48 3.5 3.5 ( .- � .. ............. Denotes Concrete Anchor Screw 25 32 25 Gen. Pad Gen. Generator Mounting Plate - See Manuf. Specifications ._�.;-�.----- —;. ------ L3.5 3.5 9.0 8 20.0 8 9.0 •••••• : . . .... ...... Bolt Placement • • • ; • • n.t.s. ...... .... • ...... .... . .. ..... •-•-!• • .. ... .. . ...... ...... . . Generator Generator Attachment Plate _ See Generator Specs VE r._- 2tt Rubber Vibration Pad/� a MasterFiber Mac 100 Grid' j / ---_ Structural Foam Core-- --2"- Anchor Bolt Plan n. t. s. _ 1 /2" x 2" x 3" Galy. Metal Washer 1 /2" x 3" Titan Conc. Anchor Screw --- 6,000 psi Lightweight Conc. Mix This Certifies that these plans meet or exceed the 186 mph ultimate wind speed of the 2010 Florida Building Code and ASCE 7-10 By Date Revision GWW 'Data: 06-29-2010 �tsfat: Title of Page: wilSnn ph. am.eaz�n�z Specific Purpose d66 RUr ilbersflr/d.Ae enur t'•�nv eax -�eai Generator Pad re-Manuf. PSignattl //amevdr dpri.4s. M4. 32T/6 rhwengr @ earthlink.net 9 W Seslc: n.t.s. Concrete Specs OPTIONAL: -Hole to be Epoxy Filled Before Installing Screw Wind Speed= 186 MPH Wind Exposure Category = "D" Not Hazardous to Human Health H. Wilson, P.E. Use. No. 9710 Sheet 1 28 MI OPTIONAL AT Acrylic -Tie' is a two component, high solids. 10:1 ratio acrylic -based anchor -grouting adhesive for use as a high strength, ancta -0 g material. Formulated for use in all types of weather. AT is designed to dispense easily and cure at temperatures down to 0•F. Resin and initiator are dispensed and mixed simultaneously through the mixing nozzle. AT meets the physical requirements of ASTM C881, Type I b IV. Grade 3, Classes A. 8 8 C. except Acrylic -Tie is a non -epoxy product formulated for fast cure time. ® • Threaded rod anchoring • Rabat doweling _ • Pick -proof sealant around doors, windows and fixtures l I ICC-ES ER-5791- (CMU 8 URM); City of L.A. RR25459-; Florida FL 115D6.1'; NSF/ANSI Standard 61 (11 in'75000 gal): Multiple DDT listings. m The load tables list values based upon results from the most recent testing and may not reflect those in current code reports. Where code jurisdictions apply. consult the current reports for applicable load values. 'Applies to all AT products except AT10. Surfaces to receive adhesive must be clean and Tree of frost. The base material temperature must be 0•F or above at the lime of installation. For information on installations below 0•F contact Simpson. Mixed material in nozzle can harden in 5-7 minutes. For installations in or through standing water, see page 15 for details. ®' ' See pages 4-5. ® 12 months from date of manufacture in unopened cartridge. i • • 1 1 r For best results store between 32•F-80•F. Partially used cartridges can be stored for a limited time by leaving nozzle in place. To re -use, attach new nozzle. I r • Resin - white. initiator - black When property mixed. adhesive will be a uniform gray color. Uncured material - Wipe up with cotton cloths. It desired approved, solvents such as ketones (MEK, acetone, etc.). lacquer thinner, OF adhesive remover can be used. DO NOT USE SOLVENTS TO CLEAN ADHESIVE FROM SKIN. Take appropriate precautions when handling flammable solvents. Solvents may damage surfaces to which they are applied. Cured material - Chip or grind off surface. Anchors installed with AT Acrylic -Tie' adhesive have been tested in accordance with ICC-ES's Acceptance Criteria for Adhesive Anchors (AC58) for the following: • Seismic.'wind loading • Long-term creep at elevated -temperature • Static loading at elevated -temperature • Damp and water -filled holes • Freeze -thaw conditions • Critical and minimum edge distance and spacing In addition, anchors installed with AT Acrylic-Tiee adhesive have been tested in accordance with ICC-ES s Acceptance Criteria for Unreidorced Masonry Anchors (AC60) and NSF/ANSI Standard 61. Drinking Water System Components - HeaRh Effects. 1® a, Consistency (77'F) ASTM C 881 Non-sag/thixotropic paste Heat deflection ASTM D 648 149-F (65-C) Bond strength (moist cure) ASTM C 882 2,900 psi (2 days) 2.970 psi(14 days) Water absorption ASTM D 570 0.23% (24 hours) Compressive yield strength ASTM D 695 10.210 psi (7 days) Compressive modulus ASTM D 695 660.800 psi (7 days) Gel time (77•F) ASTM C 881 9 min - Thin film Very good to excellent against distilled water and inorganic acids. Fair to good against organic acids and alkalis, inorganic alkalis, and many organic solvents. Poor against ketones. For more detailed information van our website Or contact Simpson Strong -Tie and request Technical Bulletin T-SAS-CHEMRES06. The performance of this product results from its unique formulation which is proprietary to Simpson Strong -Tie. The product may also be protected by one or more of U.S. Pats, 5,643.994; 5.965.635: 6,228,207, licensed from ITW. (t tt f1, tht ;4AMN813 AT13 (ATOB similar) AOTS13B Ll f i tall t� FAST -PAC"" AT10 AT30 EMN221 (ATPAC05KT) Includes 9.6 ounce (The EMN22i is the Includes 5 ounce cartridge, and required mixing nozzle coaxial cartridge, mixing nozzle. for the AT30) adaptor and mixing nozzle. -IMPORTANT- SEE PAGES 4-5 When the concrete ' temperature is at or below FOR INSTALLATION INSTRUCTIONS freezing, ensure any holes drilled in advance are free of frost or ice. I I Anchoring adhesive shall be a two -component acrylic based system supplied in manufacturer's standard side -by -Side or coaxial cartridge and dispensed through a static -mixing nozzle supplied by the manufacturer. Adhesive shall meet the physical requirements of ASTM C-881 for Type I and IV. Grade 3. Class A, B and C and must develop a minimum 10,210 psi compressive yield strength after 7 day cure. Adhesive must have a heat deflection temperature of a minimum 149•F (65•C). Adhesive shall be AT Acrylic -Tice adhesive from Simpson Strong -Tie, Pleasanton, CA. Anchors shall be installed per Simpson Strong -Tie instructions for AT Acrylic -Tie' adhesive. See pages 88-92 of the Simpson Strong -Tie Anchor ystemsr nchoring and fastening Systems for Concrete and Masonry catalog (C-SAS-2009) for information on dispensing tools, mixing nozzles and other accessories. Tension Loads in Normal -Weight Concrete m r- an on EteaaL. 1>W9at. crlanal. .. Tar•laa Lead � PoL2MIP1 " r Llmpt razAmpol IN. -Be- asp Ba64-- '%aee�M. lea) tits. M. Otrl. Ohr. 0.81Ra lyaerah 78Pa eWsra4 (Z7.8afr. fwrleata Y. lam) u• la: UtawY sd. Ma. AlrraMa - AMauaN � UYm" a m. Oar. Aaaaau . . .Owa) .� (ats0 _- BR ,tat On. � tla: Nr on. 'Ms. b. wo 2% 4,297 1,075 1.315 6,204 1.550 af, I (70 3 6 19.1 (We 15.8 27.6) 6.9 (9.5) %3% (76) ( (152) 7.087 347 ( 1,778 2.115 9.820 1.434 2.455 951 31.5 1 (1.5 17.9 (9A) (43.7 (6A) 101) 244 AXIS 1.156 1AM 1.5M ' I" y - .5 5./ 6. 293 -8 7.413 112 1,a56 2,278 /•.74it - M 2,MS _(12.7). 92 (t02)., (203) 0 _ - 1.6) (8.3 - 10.1 471 .71 2.88r (Ili) L918 '61G 1 - 18.Y78 ' I t5. 287 '-^ 13 Y.678 tU 82M 4.1 75,iN 69. 10.4 _ 17.1 2i: I 4,610 1,155 1.4N 6.560 1.645 70' f I (20.5 (5.1) (6.2) (29.3) 7.3) % % 5 I 10 4A 8.742 i (38.9) 815 (2.7 2.195 (9.7) 2.630 (11.7) - 12,Z86 (54.7) 1,604 (7.1) -t 3,W8 I (13.71 05.9) �f15) i 5% (127) (254) 1`3 1.764 3.248 3.955 116.68111 , 4,570 I (146)_1 (57.6) (7.8) i17.6) 183.11 (20.6) ' I% 4,671 -(144) '1.170 "a - a.w 1,60 (20.8) - (5. 6.3) (293) 3) ly.. 6/2 Is" JAN �� - 2.sn � � 3,479 17AZS 1.591(19.1) lr_'tol (152) (305) 460 4.9 .11s 1s .5 - •11 19.413.765 IAH6 3.4w 4,9567q J __ - ._01�1 --(4?)._�.. f15.J) - L78. ��8A1) (7.81 �J see !rotes Below Sheaf Leads In Normal-Walabi Conerah Sea Faye 51. a i eapbna:ron di the load role i.. M size Orta HrwM. edkO O0111434 -_---•'- smw 1a66 .. han"8d t. � rsaa8Mf1a1 ' -. h2p08 t41 Y: as • Delta• : E!p spwag. 4d) Ohl : tNY 17 6 ara Caeerate MIS)nati Caa J 6�a CaarreM WtlmY' BY. Deis.. AAMWO Aumaw UnTAft Bel. On: AROWAN : In.(m) f ' , ) 11>rd OL as. Oa. ILL : raa. .. M. 11L -: 1� 6,353 1.665 1.565 1.Tt8 AL % (70 4% 1 6 (283 � (7.1 (7A) 31A 6,377 1,606 1.525 1.670 1.740 (9-5) (114) 1152) I(95) (28A) I (41) (7.1) (7.411771 Y.ipB '@.9.et► _ LIN L475 ` 1,M6 % 1r} 2% ". B • %324 I.M: - 2,838 - -Y,786 ' 18,MT, M7, B (12.7) , -. -{152) L(203) _: tiS '_ f0./ - - 12. 9 - 71 145 Btti 11.818 12a6 ' 2" Y.495 (70) I I (345) ! .-- _{11.1) 18607 (82.8) 16511 (7.31 4 %i 0(15.9) (387) 3 (81) 2,175 19.71 315 14 1,65805 (20.7) 091) I (254) l 54: (146) 12.498 (55.6) 1 2,227 (9.9) 9.125 113.91 3.890 1 (17.3) _ 4.659 (20.7) Y%+ - - t - .T,AY 1,BM r Tt - 1L (51-01 12.M5 rIf.t/2; 2" 21M'a 4AM ^ '2NM8 .,iY OM ti 178• � V% 18,1f13 3" 4.9M . . BAM 24,tiM - ?a a,179 - 1 , 0 15.8 ;: 22 N A ' I The allowable bads listed are based on a safety hctor 014.0. 4. The mmIw m r rele 1h0ness is 1','. times the embed'nehe depth. l 2. 0ir ade roads may be,nceeSed 33'nt: 1a sron term loading 5. Tensbh and S%t& bads IN the Tren nD encho, may be mmb nen used the Neptul due to wild a 6eamx tones w" pe-tild by code mienchon Mahon hh.w. mio-ble bad may be 'teryalaed IN mMrete 3. Rtle' lc 00.1tae 10,0-01._l 1 WIN's IN spa619 and edge edmpr-. s.engths be,- 2000 psi V 4000 psi. d,9- o1 pages 125-129. Titen HD• Anchor Product Data - Zinc Plated sin ` pa.) Model No. DriOIIC' Wresm " OIL sis. (in.) (In.► Dg�rlgp Box CaAon �76 50 20000H950 20000H 50 100 &3THD373DIHO WH 50 100 1� �4 25 tooM20 B01hIF ODH 20. 80 %x6 _THD50600H .2D so . h it 8h - THD50612H 20 . .40- 1 h x 8 THDSOe00H 20 40 . h x 12 THD501200H 20 1hx13 THD501300H. 20 40 h x 14. THD50140M 20 40: %x 15 . THD501500H 20 40 i %x4 THD62400H I ' 1e 1$/1e 1 - I 1 10 40 %x 5 THD625ooH 10 40 %x6 THD62600H 10 40 % x 6h THD62612H l 10 40 % xB THD62800H 10 20 1 3y4x4 THD754ODH Y4TM 11x6 + 10 40 ?✓tees THD75500H 5 20 `V. x 6 THDT75600H 51 120 .Y. x 7 1111575700H -t 5, 10 :144 x B1A THD75812H 5 10 4L IF 10 -THD75100H 5 � ._ ­10 10 1. Zinc plating meets ASTM B633, SC1. 2. Length is measured from the underside at the head to the tip of the anchor. AM ERR CAST �~.amerkcasting.com "MADE IN AMERICA!" FED TAX # 20-8252362 LICENSE #599-20050163 5303 Palmetto Ave. Fort Pierce, Fl. 34982 Tel. 772-971-1958 Fax: 772464-0509 Email: calecG?ameri-castine.com or charlesnitt2001r:vahco.com UM BHT.' iffBB Serrated teeth on the tip of the Titen HD• screw anchor facilitate eutllng and reduce Installation torque. MR Titan HDO screw •U.S.ryteK •i••--- �••••• 5%it,835 i • • • • 6,623.228 • • •••••• • •••• •••••• • • a • • •• •• •• • •••••• •••••• • • • • • • • •• • • •• •••• • No special drill bit needed: Designed to install using standard sized ANSI tolerance drill bits • Installs with 50% less torque: Testing shows that when compared to competitors, the Titan HD requires 50% less torque to be installed in concrete. • Hex -washer head: Requires no separate washer and provides a clean installed appearance.' • Removable: Ideal for temporary anchoring (e.g. formwork, bracing) or applications where fixtures may need to be moved. Re -use of the anchor to achieve listed load values is not recommended. See reinstallation note on next page. Reinstallation of Titan HD" screw anchor in Original Drilled Hole Then HD anchors may be removed and reinstalled in the original hole without reducing load capacity if the threads that were cut into the concrete during the original installation are followed. Start reinstallation of the anchor by hand to prevent cross -threading and a possible reduction in load capacity. This Certifies that these plans meet or exceed the 186 mph ultimate wind speed of the 2010 Florida Building Code and ASCE 7-10 By Date Revision after; Title of Page: eviljon Dww: GWW Dort: 06-29-2010 Specific Purpose ft. 4076824" dtS64i/ev,/hers a/d.Reama� ra.4o1x12:txu Pre Manuf. RHW �..�: n.t.s. Generator Pad Concrete S e, .Rltrn.,ev,te-d,/„•!»gs. a7ea. d271b tfiwengr @ earthlink.net 4'y"' p Wind Speed = 186 MPH Wind Exposure Category = "D" Not Hazardous to Human Health H. Wilson, P.E. Lisc. No. 9710 Sheet 1